Home

EUROLITE SB-1000 User Manual

image

Contents

1. A skilled person has to approve the flying construction before every use This approval includes appearance and load tests when moved in accordance with the BGV A2 for electrical devices 5 1 Rack Installation This power distributor is built for 19 racks 483 mm The rack you use should be a Double Door Rack where you can open the frontpanel and the rear panel The rack should be provided with a cooling fan When mounting the power distributor into the rack please make sure that there is enough space around the device so that the heated air can be passed on Steady overheating will damage your device You can fix the power distributor with four screws M6 in the rack 12 14 30248370_V_1_0 DOC Be careful when mounting the power distributor into the rack Put the heaviest devices into the lower part of the rack Be aware that fastening the power distributor with four screws on the front panel is not enough In order to ensure safety additional fastening by using ground and side bars is necessary 5 2 Connections 5 2 1 Connection with the mains To connect the device to the mains you will need a power cord with a 5 pole 380 400 V 16A CEE plug DANGER TO LIFE The electric connection must only be carried out by a qualified electrician 5 2 2 Outputs Output is via 9 safety sockets Connect your loads via the output sockets The maximum load per channel is 3 680 W resistive Please note that the maximum current must never be excee
2. uUrallike BEDIENUNGSANLEITUNG USER MANUAL SB 1000 Power Distributor SI Ke W 1 eurolike SB 1000 C L2 F r weiteren Gebrauch aufbewahren Keep this manual for future needs Copyright Nachdruck verboten Reproduction prohibited MULTI LANGUAGE INSTRUCTIONS Inhaltsverzeichnis Table of contents is EINFOHRUNG see ege dies un ae nn Dane En EE EE 3 KEN ONS VU EE 3 3 BESTIMMUNGSGEM RE VERWENDUNG EE 5 A GERATEBESCHREIBUNG insitscesictscsececedsazesessaiceccdssizenaisasdexsaciscevesaedtencocstusesutecvdaccveejieesaidisvicssseneiedussduaatiiacs 6 4 1 Foata Senerare Re EE 6 42 GOTALCUDEISICIN E 6 h a E EE TET E E E AT T 6 5 1 E ele EE 7 9 2 Ee EE 7 6 REINIGUNG UND WARTUNG cccccccccsseeccnesseccsneesesnesseeuneeesecuauueeeenauseeeaneuseauaussseanauseseaneeseauaueeseanausesnanes 7 7 TECHNISCHE DATE N eege eege EE EE 8 INTRODUCTION rera sense san sense an nad ee Tann ee anna nes snedacsasdueaesasececceseeceesicnucaaseites 9 2 SAFETY INSTRUCTIONS EE 9 3 OPERATING DETERMINATIONS 22u200222000000000000n00000nnnnnunnunnnnnnnannnnnnnnnnnnnannn nn nn annnnnnnnnunnannnnnnnannnnnnnnnnnnnn 10 4 DESCRIPTION ME 11 SEET Ee EE Ee 11 4 2 Description Of the device rnrn reet ntEnnAn nnne EE EEn neneme EEEn Eneee 12 5 INSTALLATION 2 3 2u3422022422 00020002 ana aaa aaa an nn a Ears AE Nae aSr 12 5 1 ext 67 lt C211 111
3. 0 EE 12 9 21 CORNECUONS EE 13 6 CLEANING AND MAINTENANCE cccccccecceseeccceesecneseeecnsseeeeueseenausneeensuseseauaseanaueseanesseseeueesesenageeeeas 13 7 TECHNICAL SPECIFICATIONS wississssccccsissccsaccanscasceccessaiccasassiceeasecciensscccsanvaccdasstecaasiveecsadsenbeasceens nannan nna 14 Das neueste Update dieser Bedienungsanleitung finden Sie im Internet unter You can find the latest update of this user manual in the Internet under www eurolite de 2 14 30248370_V_1_0 DOC Deutsch BEDIENUNGSANLEITUNG eurolle SB 1000 Stromverteiler Alle Personen die mit der Aufstellung Inbetriebnahme Bedienung Wartung und Instandhaltung dieses Ger tes zu tun haben m ssen entsprechend qualifiziert sein diese Bedienungsanleitung genau beachten die Bedienungsanleitung als Teil des Produkts betrachten die Bedienungsanleitung w hrend der Lebensdauer des Produkts behalten die Bedienungsanleitung an jeden nachfolgenden Besitzer oder Benutzer des Produkts weitergeben sich die letzte Version der Anleitung im Internet herunter laden 1 EINF HRUNG Wir freuen uns dass Sie sich f r eine EUROLITE SB 1000 Stromverteiler entschieden haben Wenn Sie nachfolgende Hinweise beachten sind wir sicher dass Sie lange Zeit Freude an Ihrem Kauf haben werden Nehmen Sie die SB 1000 aus der Verpackung Bitte berpr fen Sie vor der ersten Inbetriebnahme ob Transportsch den vorliegen In diesem Fall nehmen Si
4. Die Pr ffristen f r ortsver nderliche elektrische Betriebsmittel BGV A2 sind einzuhalten Der Unternehmer hat daf r zu sorgen dass die elektrischen Anlagen und Betriebsmittel vor der ersten Inbetriebnahme und nach einer nderung oder Instandsetzung vor der Wiederinbetriebnahme durch eine Elektrofachkraft auf ihren ordnungsgem en Zustand gepr ft werden Elektrische Anlagen und Betriebsmittel d rfen nur in ordnungsgem em Zustand in Betrieb genommen werden und m ssen in diesem Zustand erhalten werden Zur Erhaltung des ordnungsgem en Zustandes sind elektrische Anlagen und Betriebsmittel wiederholt nach Art und Umfang der in den elektrotechnischen Regeln festgelegten Ma nahmen zu pr fen Die Verantwortung f r die ordnungsgem e Durchf hrung der Pr fungen obliegt einer Elektrofachkraft Ortsver nderliche elektrische Betriebsmittel Verl ngerungs und Ger teanschlussleitungen mit Steckvorrich tungen Anschlussleitungen mit Stecker und bewegliche Leitungen mit Stecker und Festanschluss m ssen alle drei Monate durch eine Elektrofachkraft auf ordnungsgem en Zustand gepr ft werden Sollten Sie noch weitere Fragen haben steht Ihnen Ihr Fachh ndler jederzeit gerne zur Verf gung 7 TECHNISCHE DATEN Max Gesamtleistung 11040 W Ma e LxBxH 485 x 210 x 90 mm Eigengewicht 2 3 kg Bitte beachten Sie Technische Anderungen ohne vorherige Ankiindigung und Irrtum vorbehalten 22 11 2004 eu ro Germany
5. alle vier Jahre durch einen Sachverst ndigen im Umfang der Abnahmepr fung gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens einmal j hrlich durch einen Sachkundigen gepr ft werden Dabei muss unter anderem auf folgende Punkte besonders geachtet werden 1 Alle Schrauben mit denen das Ger t oder Ger teteile montiert sind m ssen fest sitzen und d rfen nicht korrodiert sein 2 An Geh use Befestigungen und Montageort Decke Abh ngung Traverse d rfen keine Verformungen sichtbar sein 3 Die elektrischen Anschlussleitungen d rfen keinerlei Besch digungen Materialalterung z B por se Leitungen oder Ablagerungen aufweisen Weitere auf den jeweiligen Einsatzort und die Nutzung abgestimmte Vorschriften werden vom sachkundigen Installateur beachtet und Sicherheitsm ngel behoben 7 14 30248370_V_1_0 DOC LEBENSGEFAHR Vor Wartungsarbeiten unbedingt allpolig vom Netz trennen Das Ger t sollte regelm ig von Verunreinigungen wie Staub usw gereinigt werden Verwenden Sie zur Reinigung ein fusselfreies angefeuchtetes Tuch Auf keinen Fall Alkohol oder irgendwelche L sungsmittel zur Reinigung verwenden Im Ger teinneren befinden sich keine zu wartenden Teile Wartungs und Servicearbeiten sind ausschlie lich dem autorisierten Fachhandel vorbehalten Sollten einmal Ersatzteile ben tigt werden verwenden Sie bitte nur Originalersatzteile
6. ckseite 5 16A Drehstrom Ausgangsdose 6 16A Drehstrom Eingangsstecker 5 INSTALLATION LEBENSGEFAHR Bei der Installation sind insbesondere die Bestimmungen der BGV C1 vormals VBG 70 und DIN 15560 zu beachten Die Installation darf nur vom autorisierten Fachhandel ausgef hrt werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen vor der ersten Inbetriebnahme und nach wesentlichen nderungen vor der Wiederinbetriebnahme durch Sachverst ndige gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens alle vier Jahre durch einen Sachverst ndigen im Umfang der Abnahmepr fung gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens einmal j hrlich durch einen Sachkundigen gepr ft werden 6 14 30248370_V_1_0 DOC Flugeinrichtungen sind durch Sachkundige vor jedem Einsatz zu pr fen Die Pr fung umfasst Sichtpr fung und Belastungsproben in Bewegung gem BGV A2 f r elektrische Betriebmittel 5 1 Rackinstallation Dieser Verteiler ist f r ein 19 Rack 483 mm vorgesehen Bei dem Rack sollte es sich um ein Double Door Rack handeln an dem sich sowohl die Vorder als auch die R ckseite ffnen lassen Das Rackgeh use sollte mit einem L fter versehen sein Achten Sie bei der Standortwahl des Verteilers darauf da d
7. the direct smoke jet and is installed in a distance of 0 5 meters between smoke machine and device The ambient temperature must always be between 5 C and 45 C Keep away from direct insulation particularly in cars and heaters The relative humidity must not exceed 50 with an ambient temperature of 45 C This device must only be operated in an altitude between 20 and 2000 m over NN The ambient contamination must never exceed level 1 and must not be conducting only dry Never use the device during thunderstorms Over voltage could destroy the device Always disconnect the device during thunderstorms Operate the device only after having familiarized with its functions Do not permit operation by persons not qualified for operating the device Most damages are the result of unprofessional operation Never use solvents or aggressive detergents in order to clean the device Rather use a soft and damp cloth Please use the original packaging if the device is to be transported Inspection deadlines according to BGV A2 for electrical resources must be complied with Please consider that unauthorized modifications on the device are forbidden due to safety reasons If this device will be operated in any way different to the one described in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock crash etc 4 DESCRIPTIO
8. und die Sicherheit Dritter Das Ger t darf nicht in einer Umgebung eingesetzt oder gelagert werden in der mit Spritzwasser Regen Feuchtigkeit oder Nebel zu rechnen ist Feuchtigkeit oder sehr hohe Luftfeuchtigkeit kann die Isolation reduzieren und zu t dlichen Stromschl gen f hren Beim Einsatz von Nebelger ten ist zu beachten dass das Ger t nie direkt dem Nebelstrahl ausgesetzt ist und mindestens 0 5 m von einem Nebelger t entfernt betrieben wird Die Umgebungstemperatur muss zwischen 5 C und 45 C liegen Halten Sie das Ger t von direkter Sonneneinstrahlung auch beim Transport in geschlossenen W gen und Heizk rpern fern Die relative Luftfeuchte darf 50 bei einer Umgebungstemperatur von 45 C nicht berschreiten Dieses Ger t darf nur in einer H henlage zwischen 20 und 2000 m ber NN betrieben werden Der Umgebungsverschmutzungsgrad darf 1 nicht berschreiten keine oder nur trockene nichtleitende Verschmutzung Verwenden Sie das Ger t nicht bei Gewitter berspannung k nnte das Ger t zerst ren Das Ger t bei Gewitter allpolig vom Netz trennen Netzstecker ziehen Nehmen Sie das Ger t erst in Betrieb nachdem Sie sich mit seinen Funktionen vertraut gemacht haben Lassen Sie das Ger t nicht von Personen bedienen die sich nicht mit dem Ger t auskennen Wenn Ger te nicht mehr korrekt funktionieren ist das meist das Ergebnis von unsachgem er Bedienung Reinigen Sie das Ger t niemals mit L sungsmitt
9. 8 14 30248370_V_1_0 DOC English USER MANUAL euro SB 1000 Power Distributor Every person involved with the installation operation and maintenance of this device has to be qualilfied follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of the product pass this manual on to every further owner or user of the product download the ultimate version of the user manual from the Internet 1 INTRODUCTION Thank you for having chosen a EUROLITE SB 1000 power distributor If you follow the instructions given in this manual we are sure that you will enjoy this device for a long period of time Unpack your SB 1000 Before you initially start up please make sure that there are no transport damages Should there be any do not take the device into operation and immediately consult your dealer 2 SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual Important JE Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability
10. N 4 1 Features Practical 16A distributor in 19 housing Designed for mounting in 19 racks 2U necessary for installation 16A three phase current input plug and output socket Control lamps indicate each phase 3 safety sockets on the housing front 1 per phase 6 safety sockets on the housing rear 2 per phase 11 14 30248370_V_1_0 DOC 4 2 Description of the device CT Cu ie euroliie SB 1000 GET Ce WI oC 1 19 rack mounting holes 2 Control lamps 3 Power distribution sockets front 4 Power distribution sockets rear 5 16A three phase current output socket 6 16A three phase current input plug 5 INSTALLATION DANGER TO LIFE Please consider the DIN 15560 and the respective national norms during the installation The installation must only be carried out by an authorized dealer The operator has to make sure that safety relating and machine technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another time The operator has to make sure that safety relating and machine technical installations are approved by an expert after every four year in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are approved by a skilled person once a year
11. dass der Adernquerschnitt f r die ben tigte Stromzufuhr des Ger tes zugelassen ist Alle Warnhinweise f r die Netzleitung gelten auch f r evtl Verlangerungsleitungen Ger t bei Nichtbenutzung und vor jeder Reinigung vom Netz trennen Fassen Sie dazu den Netzstecker an der Griffl che an und ziehen Sie niemals an der Netzleitung Ansonsten kann das Kabel und der Stecker besch digt werden was zu t dlichen Stromschl gen f hren kann Sind Stecker oder Ger teschalter z B durch Einbau nicht erreichbar so muss netzseitig eine allpolige Abschaltung vorgenommen werden Wenn der Netzstecker oder das Ger t staubig ist dann muss es au er Betrieb genommen werden der Stromkreis muss allpolig unterbrochen werden und das Ger t mit einem trockenen Tuch gereinigt werden Staub kann die Isolation reduzieren was zu t dlichen Stromschl gen f hren kann St rkere Verschmut zungen im und am Ger t d rfen nur von einem Fachmann beseitigt werden Es d rfen unter keinen Umst nden Fl ssigkeiten aller Art in Steckdosen Steckverbindungen oder in irgendwelche Ger te ffnungen oder Ger teritzen eindringen Besteht der Verdacht dass auch nur minimale Fl ssigkeit in das Ger t eingedrungen sein k nnte muss das Ger t sofort allpolig vom Netz getrennt werden Dies gilt auch wenn das Ger t hoher Luftfeuchtigkeit ausgesetzt war Auch wenn das Ger t scheinbar noch funktioniert muss es von einen Fachmann berpr ft werden ob durch den Fl ssigkei
12. ded DANGER TO LIFE Before taking into operation for the first time the installation has to be approved by an expert 6 CLEANING AND MAINTENANCE The operator has to make sure that safety relating and machine technical installations are inspected by an expert after every four years in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are inspected by a skilled person once a year The following points have to be considered during the inspection 1 All screws used for installing the devices or parts of the device have to be tighly connected and must not be corroded 2 There must not be any deformations on housings fixations and installation spots ceiling suspension trussing 3 The electric power supply cables must not show any damages material fatigue e g porous cables or sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed DANGER TO LIFE Disconnect from mains before starting maintenance operation We recommend a frequent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents There are no serviceable parts inside the device Maintenance and service operations are only to be carried out by authorized dealers Should you need any spare parts please use genuine parts The examination intervals for m
13. e das Ger t nicht in Betrieb und setzen sich bitte mit Ihrem Fachh ndler in Verbindung 2 SICHERHEITSHINWEISE ACHTUNG Seien Sie besonders vorsichtig beim Umgang mit gef hrlicher Netzspannung Bei die ser Spannung k nnen Sie einen lebensgef hrlichen elektrischen Schlag erhalten Dieses Ger t hat das Werk in sicherheitstechnisch einwandfreiem Zustand verlassen Um diesen Zustand zu erhalten und einen gefahrlosen Betrieb sicherzustellen muss der Anwender die Sicherheitshinweise und die Warnvermerke unbedingt beachten die in dieser Bedienungsanleitung enthalten sind Rms Unbedingt lesen Bei Sch den die durch Nichtbeachtung der Anleitung verursacht werden erlischt der Garantiean spruch F r daraus resultierende Folgesch den bernimmt der Hersteller keine Haftung Das Ger t darf nicht in Betrieb genommen werden nachdem es von einem kalten in einen warmen Raum gebracht wurde Das dabei entstehende Kondenswasser kann unter Umst nden Ihr Ger t zerst ren Lassen Sie das Ger t solange uneingeschaltet bis es Zimmertemperatur erreicht hat Bitte berpr fen Sie vor der ersten Inbetriebnahme ob kein offensichtlicher Transportschaden vorliegt Sollten Sie Sch den an der Netzleitung oder am Geh use entdecken nehmen Sie das Ger t nicht in Betrieb und setzen sich bitte mit Ihrem Fachh ndler in Verbindung 3 14 30248370_V_1_0 DOC Der Aufbau entspricht der Schutzklasse I Der Netzstecker darf nur an eine Schutzkontakt Stec
14. eln oder scharfen Reinigungsmitteln sondern verwenden Sie ein weiches und angefeuchtetes Tuch Soll das Ger t transportiert werden verwenden Sie bitte die Originalverpackung um Transportsch den zu vermeiden Die Pr fungsfristen gem BGV A2 f r elektrische Betriebsmittel m ssen eingehalten werden Beachten Sie bitte dass eigenm chtige Ver nderungen an dem Ger t aus Sicherheitsgr nden verboten sind Wird das Ger t anders verwendet als in dieser Bedienungsanleitung beschrieben kann dies zu Sch den am Produkt f hren und der Garantieanspruch erlischt Au erdem ist jede andere Verwendung mit Gefahren wie z B Kurzschluss Brand elektrischem Schlag Abst rzen verbunden 5 14 30248370_V_1_0 DOC 4 GERATEBESCHREIBUNG 4 1 Features Praktischer 16A Stromverteiler im 19 Gehause Besonders geeignet zum Einbau in 19 Verstarkerracks Zum Einbau werden nur 2 HE ben tigt 16A Drehstrom Eingangsstecker und Ausgangsdose Kontrollleuchten f r die Pr senz jeder einzelnen Phase 3 Schutzkontaktsteckdosen auf der Frontseite 1 pro Phase 6 Schutzkontaktsteckdosen auf der R ckseite des Ger tes 2 pro Phase 4 2 Ger te bersicht Cie Cu e OD euros sB 1000 1 Ju Ce WI 1 Befestigungsl cher f r Rackmontage 2 Phasen Kontrollleuchten 3 Schutzkontaktsteckdosen Frontseite 4 Schutzkontaktsteckdosen R
15. for any resulting defects or problems If the device has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature Please make sure that there are no obvious transport damages Should you notice any damages on the A C connection cable or on the casing do not take the device into operation and immediately consult your local dealer 9 14 30248370_V_1_0 DOC This device falls under protection class I The power plug must only be plugged into a protection class outlet The voltage and frequency must exactly be the same as stated on the device Wrong voltages or power outlets can lead to the destruction of the device and to mortal electrical shock Always plug in the power supply plug least The power plug must always be inserted without force Make sure that the plug is tightly connected with the outlet Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Never touch them with wet hands as this could lead to mortal electrical shock Never modify bend strain mechanically put pressure on pull or heat up the power cord Never operate next to sources of heat or cold Disregard can lead to power cord damages fire or mortal electrical shock The cable insert or the female part
16. ie warme Luft aus dem Rack entweichen kann und gen gend Abstand zu anderen Ger ten vorhanden ist Dauerhafte berhitzung kann zu Sch den an des Verteilers f hren Sie k nnen den Verteiler mit vier Schrauben M6 im Rack befestigen Werden mehrere Verteiler bereinander montiert so ist darauf zu achten da zwischen den Ger ten mindestens 1 H heneinheit Luft bleibt Seien Sie vorsichtig beim Einbau des Verteilers in ein Rack Bauen Sie die schwersten Ger te in den unteren Teil des Racks ein Die Frontplatte allein reicht allerdings nicht aus um einen Verteiler sicher zu befestigen Es mu eine gleichm ige Befestigung durch Boden und Seitenschienen gew hrleistet sein 5 2 Anschl sse 5 2 1 Anschluss ans Netz Zum Netzanschluss ben tigen Sie eine Anschlussleitung mit einem 5 poligen 380 400 V 16 A CEE Stecker LEBENSGEFAHR Lassen Sie den elektrischen Anschluss nur vom autorisierten Fachhandel ausf hren 5 2 2 Ausg nge Die Ausg nge gehen ber 9 Schutzkontaktsteckdosen ber die Ausgangsbuchsen schlie en Sie Ihre Verbraucher an Die maximale Nennleistung betr gt pro Kanal 3680 W Bitte beachten Sie dass der maximale Gesamtstrom niemals berschritten werden darf LEBENSGEFAHR Vor der ersten Inbetriebnahme muss die Einrichtung durch einen Sachverst ndigen gepr ft werden 6 REINIGUNG UND WARTUNG Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens
17. in the device must never be strained There must always be sufficient cable to the device Otherwise the cable may be damaged which may lead to mortal damage Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time If extension cords are used make sure that the core diameter is sufficient for the required power consumption of the device All warnings concerning the power cords are also valid for possible extension cords Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord Otherwise the cable or plug can be damaged leading to mortal electrical shock If the power plug or the power switch is not accessible the device must be disconnected via the mains If the power plug or the device is dusty the device must be taken out of operation disconnected and then be cleaned with a dry cloth Dust can reduce the insulation which may lead to mortal electrical shock More severe dirt in and at the device should only be removed by a specialist There must never enter any liquid into power outlets extension cords or any holes in the housing of the device If you suppose that also a minimal amount of liquid may have entered the device it must immediately be disconnected This is also valid if the device was exposed to high humidity Also if the device is still
18. kdose angeschlossen werden deren Spannung und Frequenz mit dem Typenschild des Ger tes genau bereinstimmt Ungeeignete Spannungen und ungeeignete Steckdosen k nnen zur Zerst rung des Ger tes und zu t dlichen Stromschl gen f hren Den Versorgungsnetzstecker immer als letztes einstecken Der Netzstecker muss dabei gewaltfrei einge setzt werden Achten Sie auf einen festen Sitz des Netzsteckers Lassen Sie die Netzleitung nicht mit anderen Kabeln in Kontakt kommen Seien Sie vorsichtig beim Umgang mit Netzleitungen und anschl ssen Fassen Sie diese Teile nie mit feuchten H nden an Feuchte H nde k nnen t dliche Stromschl ge zu Folge haben Netzleitungen nicht ver ndern knicken mechanisch belasten durch Druck belasten ziehen erhitzen und nicht in die N he von Hitze oder K ltequellen bringen Bei Missachtung kann es zu Besch digungen der Netzleitung zu Brand oder zu t dlichen Stromschl gen kommen Die Kabeleinf hrung oder die Kupplung am Ger t d rfen nicht durch Zug belastet werden Es muss stets eine ausreichende Kabell nge zum Ger t hin vorhanden sein Andernfalls kann das Kabel besch digt werden was zu t dlichen Stromschl gen f hren kann Achten Sie darauf dass die Netzleitung nicht gequetscht oder durch scharfe Kanten besch digt werden kann berpr fen Sie das Ger t und die Netzleitung in regelm igen Abst nden auf Besch digungen Werden Verl ngerungsleitungen verwendet muss sichergestellt werden
19. obile electrical devices German BGV A2 must be kept The operator has to make sure that the electrical devices are examined by an electrician before taking into operation for the first time and after changes before taking into operation another time 13 14 30248370_V_1_0 DOC Electrical devices must only be taken into operation in a perfect condition and must be kept this way For keeping the perfect condition electrical devices must repeatedly be approved in accordance with the instructions given in the electro technical guidelines A qualified electrician is responsible for the correct examinations Mobile electrical devices extension cords with plugs power cables with plugs and mobile cables with plugs and permanent installation must be approved by an expert every three months Should you have further questions please contact your dealer 7 TECHNICAL SPECIFICATIONS Height Please note Every information is subject to change without prior notice 22 11 2004 euro WE 14 14 30248370_V_1_0 DOC
20. running the device must be checked by a specialist if the liquid has reduced any insulation Reduced insulation can cause mortal electrical shock There must never be any objects entering into the device This is especially valid for metal parts If any metal parts like staples or coarse metal chips enter into the device the device must be taken out of operation and disconnected immediately Malfunction or short circuits caused by metal parts may cause mortal injuries Keep away children and amateurs Never leave this device running unattended 3 OPERATING DETERMINATIONS This device is a power distribution for supplying current to other devices This product is only allowed to be operated with an alternating voltage of 380 400 V 50 Hz and was designed for indoor use only This device is designed for mobile use and for permanent installations The maximum power consumption of this device must never be exceeded When choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust There should not be any cables lying around You endanger your own and the safety of others 10 14 30248370_V_1_0 DOC This device must never be operated or stockpiled in sourroundings where splash water rain moisture or fog may harm the device Moisture or very high humidity can reduce the insulation and lead to mortal electrical shocks When using smoke machines make sure that the device is never exposed to
21. tseintritt eventuell Isolationen beeintr chtigt wurden Reduzierte Isolationen k nnen t dliche Stromschl ge hervorrufen In das Ger t d rfen keine fremden Gegenst nde gelangen Dies gilt insbesondere f r Metallteile Sollten auch nur kleinste Metallteile wie Heft und B roklammern oder gr bere Metallsp ne in das Ger t gelangen so ist das Ger t sofort au er Betrieb zu nehmen und allpolig vom Netz zu trennen Durch Metallteile hervorgerufene Fehlfunktionen und Kurzschl sse k nnen t dliche Verletzungen zur Folge haben Kinder und Laien vom Ger t fern halten Das Ger t darf niemals unbeaufsichtigt betrieben werden 4114 30248370_V_1_0 DOC 3 BESTIMMUNGSGEM RE VERWENDUNG Bei diesem Ger t handelt es sich um einen Stromverteiler mit dem sich andere Ger te versorgen lassen Dieses Produkt ist nur f r den Anschluss an 380 400 V 50 Hz Wechselspannung zugelassen und wurde ausschlie lich zur Verwendung in Innenr umen konzipiert Dieses Ger t ist sowohl f r den Mobilbetrieb als auch f r Festinstallationen vorgesehen Dieses Ger t ist f r professionelle Anwendungen z B auf B hnen in Diskotheken Theatern etc vorgesehen Die maximale elektrische Gesamtleistung darf niemals berschritten werden Achten Sie bei der Wahl des Installationsortes darauf dass das Ger t nicht zu gro er Hitze Feuchtigkeit und Staub ausgesetzt wird Vergewissern Sie sich dass keine Kabel frei herumliegen Sie gef hrden Ihre eigene