IND-PWR XXL User Manual - TMS · Telemetrie

image

Contents

1. Telemetrie Messtechnik Schnorrenberg Th IND PWR XXL RING COIL User Manual Inductive power supply set Power supply for power head Inductive ring coil CUL 1 00 mm for IND DATA coil CUL 0 63 mm for IND PWR coil IND PWR AC DC module AC DC Adapter Input AC from coil 120Watt 24V 5A Output 5VDC max 1000 Power Head with 5m cable TMS e Telemetrie Messtechnik Schnorrenberg e Dipl Ing Werner Schnorrenberg Habichtweg 30 D 51429 Bergisch Gladbach Tel 02204 9815 52 Fax 02204 9815 53 Mobil 0171 8902387 Bankverbindung Sparkasse Kto Nr 1900310663 BLZ 370 501 98 MT32 IND PWR 5V AC DC Module for inductive power MT32 IND PWR 5V AC DC Module for inductive power www kimt gmbh cor gt Input 30 60kHz 10 50V AC IND PWR 5V Output 5 VDC Ac IND L ie Current up to 1000mA 1000 f LED Weight 35 gram 5 see User Manuali Vibration 5g 30009 Pin assignment 5 0V OUTPUT IND PWR COIL 1000 AC INPUT KMT ambn com AC IN a 5 k IND AC IND PWR 5V AC IN b BERR 5 Max 1000 AG INS IND p Status LED BEEBE REP eee eee 5V 3 ON OK Blinking see User Manual current up to 500mA use pin At current up to 1000mA use two pins Status LED L
2. COIL inner diameter 196mm 196 ZEICHNUNGSNR lt B 2 lt gt Version 2011 06 6 Inductive power supply T O 9 1 8 1555 8161604 L L L AVLISEVW LLINHOS Version 2011 06b Dimensions of IND PWR HEAD XXL Mt32 Dimensions 41 00 INDUCTIVE POWER HEAD XXL for DISK COIL 55 00 25 00 30 00 INDUCTIVE Power Head Hole XXL 6 20 70 00 80 00 Version 2011 06 8 100 00 70 00 127 00 Dimensions of IND PWR HEAD XXL M132 Dimensions INDUCTIVE POWER HEAD XXL Coil distances 10 00 Disc with coil INDUCTIVE Power Head on Version 2011 06 0 IND PWR HEAD XXL Caution for use of power heads Cable must unrolled for use otherwise it will warm up Version 2011 06b 10 MT32 IND PWR Following must be considered at the mounting of the inductive power head Example of mounting Wrong Mounting only if metal plate cover the active area of Version 2011 06b 11 LED flashing auto adjustment LED finish IND resonance of Power head reached Power control LED Power Switch Power INPUT DC 24V 100WATT Version 2011 06b MT32 IND PWR XXL Pin connection SerB 9 D SerA 6 CONTROL Not used ag Ji o DC 24V AC 25 35kHz output 100 W
3. ATT for power head E have no function Powering out Control out of function oo gt 25 35kHz output for power head 12 The device should only applied by instructed personnel The power head emits strong magnetic radiation at 30 60 KHz to a distance of 20 cm Therefore persons with cardiac pacemakers should not work with this device Magnetic data storage media should be kept in a distance of at least 3m from the power head to avoid data loss The same 15 valid for electromagnetic sensitive parts devices and systems Do place the power head in the switched on state on metallic objects because this results in eddy currents which could overload the device and strong heat up small objects Also the probe could be destroyed No metallic objects other than the disc type coil should be located in the air gap of the power head The same applies to metallic parts within a radius of up to 30 mm in all directions Do not use damaged or faulty cables Never touch in the area between shaft and inductive head the rotating shaft itself or rotor electronic contacts during operation This is a Class A system suitable for operation in a laboratory or industrial environment The system can cause electromagnetic interferences when used in residential areas or environments In this case the operator is responsible for establishing protective procedures Version 2011 06b 13
4. ED ON right windings and good distance between head and coil LED very low blinking too less windings of IND Coil or too large distance between head and coil LED fast blinking too much windings OVER POWER at IND Coil reduce windings or module go hot and switch OFF Version 2011 06b 2 MT32 IND PWR housing dimensions m 2 5 Allen Screw gt KMT GND www kmt gmbh com GND IND PWR 5V 5V OUT max m 5V OUT 1000 Weight about 35 grams Version 2011 06b Inductive power supply RING COIL Distance power head pickup head Solder pins for power coil and wire to IND PWR 5V Please use twisted wire gt 0 25mm IND Data Pickup IND PWR Head Distance to coil Distance to coil 5 100 5 30 lt CUL 1 00 mm for IND DATA coil 1 winding CUL 0 63 mm for IND PWR coil 5 winding IND Data Pickup IND Data Pickup Distance to coil ath Distance to coil 50mm now 50mm Solder pins for data coil and wire to IND TX 40MHz Please use twisted wire gt 0 14mm If you use longer wires gt 100mm please shied the wires max 1000mm recommend only shielded Version 2011 06b 4 Inductive power supply RING COIL Distance power head PWR COIL DATA COIL 5 winding with 1 winding with CUL wire 0 63mm CUL wire 1 00mm Enamelled copper wire Enamelled copper wire Distance 5 30mm Version 2011 06b 5 Inductive power supply RING

Download Pdf Manuals

image

Related Search

Related Contents

Betriebsanleitung Analysen-Präzisionswaage  Mode d`emploi  LED MAT-192 DMX  Thrustmaster Guillemot Gaming Steering Wheel 4160545 User's Manual  Cable Détecteur GW400k Manuel Pour Les  Sunix UTS1009B  Maris Tshape FGB906WAC FR(2.26 MB, PDF)  User Manual  Operating Manual EN  M73TL VULCAN TRIACT-LOCK M735200C (220610)  

Copyright © All rights reserved.
Failed to retrieve file