1. Labtec Betriebsanleitung User Manual Labtest 400 nr Inhalt Contends Selte No Page Ger tebeschreibung Description of the Equipment BE 3 Technische Daten Specifications 2 4 Bedienelemente Operation Controls 3 gt 4 6 5 Zubeh r Accessories Inbetriebnahme Starting Up Wartung und Pflege Care and Maintenance 5 Appendices Carrying Out the Tests Pr fung von Vollmasken Testing Masks A1 Pr fung von Lungenautomaten Demand Valves A2 Pr fung von Druckminderer Testing Pressure reducer A3 Pr fung von Pressluftatmern Testing Breathing Apparatus A A Ausgabe Edition July 2005 g ltig ab Serien Nr valid from serial num www labtronic de download bal_LT_400 pdf ber 10 05 4001 Labtec GmbH D 74927 Eschelbronn Fax 49 0 6226 1587300 e mail info labtronic de www labtronic de Seite Page 1 1 Vorwort Die vorliegende Betriebsanleitung beinhaltet die Bedienung und Pflege der Pr fger te Labtest 400 ab der vermerkten Seriennummer Voraussetzung f r einen ordnungsgem en Betrieb des Ger tes ist dass ausschlie lich nach dieser Betriebsanleitung das Ger t bedient und benutzt wird Labtec haftet nicht f r irgendwelche Personen oder Sachsch den oder daraus resultierende Folgesch den gleich welcher Art wenn von der Bedienungsanleitung abweichend das Ger t eingesetzt wird Das gleiche gilt f r unsachgem e Pflege Wartungen und Reparaturen
2. am Ger t Labtec erkennt keine Gew hrleistungsanspr che an wenn das Ger t durch nicht eingewiesene Personen bedient oder gewartet oder repariert wird und wenn keine Orginal Ersatzteile bei Reparatur und Wartungs arbeiten verwendet werden Desgleichen gilt beim Offnen verplombter Teile ohne dass eine ausdr ckliche Genehmigung von Labtec vorliegt Im brigen gelten die Verkaufs und Lieferbedingungen sowie die Garantie und Gew hrleistungsbedingungen der Labtec GmbH die durch diese Hinweise in keiner Weise erweitert werden 2 Geer tebeschreibung Labtest 400 ist ein Pr fger te zum Pr fen von Atemschutzmasken EN 136 und Lungenautoma ten sowie Pressluftatmern und gasdichten Chemi kalien Schutzanz gen Das Aufblasen des Pr fkopfes erfolgt ber eine eingebaute elektrische Pumpe 3 Technische Daten 30 30 mbar Kl 1 6 Skalenteilung 0 2 mbar 0 16 bar KI 1 6 Skalentei lung 0 5 bar 0 400 bar Kl 1 6 Skalentei lung 20 bar ND Manometer MD Manometer HD Manometer Todraumvolumen ca 480 ml ohne Adapter Pumpe ca 10 l min 24 V DC Stromversorgung ber mitgelieferten Netztrafo 230 V AC 50 Hz 24 V DC Zeitmessung Stoppuhr mit LCD Anzeige vorw hlbare Zeit 1 99 min 1 Foreword This user manual describes how to maintain and care for the Labtest 400 test appliances with the serial number noted or higher Trouble free opera tion and use of the test stand
3. checks and repairs The skin is made of natural rubber latex Since latex is ozone sensitive the text head must not be placed in full sunlight During any long downtimes it is best to cover the head with a cloth or similar If it becomes dirty the test head should be well washed with soapy water The use of a microfibre cloth is recommended for this purpose Do not on any account use any solvents on the test head The skin is certainly very robust and also rela tively thick but it can be damaged by sharp ob jects and this would render it useless N B Some disinfectants can damage the latex skin of the test head if the full face masks being tested have not been rinsed 100 thoroughly after disin fection it is then possible for disinfectant residues left on the masks to come in contact with the latex skin of the test head and damage it For this rea son it is important that only disinfectant agents that contain absolutely no phosphates alde hydes or phenols are used No agents contain ing oil grease or solvents must be used on the head as these would also damage the skin Lab tec recommends that it is treated with silicon spray The service life of the text head is not covered by the guarantee If the latex skin is no longer tight because it is damaged or old or for any other reason it is pos sible to change the test head for a new one Please send your test head to our works you will then receive a replacem
4. du 1989 DIN EN 137 Ausgabe dates en date du 1993 DIN EN 837 Ausgabe dates en date du 1997 Labtec GmbH 06 04 2011 D 74927 Eschelbronn Germany Labtec GmbH Willi W Stumpf Gesch ftsf hrer CEO G rant Labtec GmbH D 74927 Eschelbronn Fax 49 0 6226 1587300 e mail info labtronic de www labtronic de Seite Page 7
5. 3 CSA Anschlusskupplung Connection for inflation of CPS 14 Hochdruck Hauptventil HP main valve 15 MD F llventil Tastventil Medium pressure inflation button Durch Bet tigung gelangt ber 13 Luft in den CSA Pushing this button inflates via 13 air in the CPS 16 Netzanschluss Power connection Mit Ein Ausschalter an R ckseite With ON OF switch on back 17 Hochdruck Festanschluss High pressure connection Labtec GmbH D 74927 Eschelbronn Fax 49 0 6226 1587300 e mail info labtronic de www labtronic de Seite Page 4 5 Zubeh r 5 Art Nr Bezeichnung Erl uterung 161 027 Dichtsetzkappe Zum Dichtsetzen des Atemanschlusses von RD 40 Normaldruck Vollmasken mit RD 40 x 1 7 EN 148 1 161 028 Dichtsetzkappe Zum Dichtsetzen des Atemanschlusses von PE 45 U berdruck Vollmasken mit metr Gewinde M 45 x 3 mm 161 032 Dichtsetzkappe Zum Dichtsetzen des Atemanschlusses von EAS berdruck Vollmasken mit Einheits Steckanschluss DIN 58 600 161 046 Adapter RD 40 Zur Aufnahme von Normaldruck LA mit RD 40 x 1 7 EN 148 1 Labtest Pr fkopf 161 048 Adapter PE 45 Zur Aufnahme von berdruck LA mit metr Gewinde M 45 x 3 in Labtest Pr fkopf 161 051 Adapter AUSV Zur Aufnahme von berdruck LA mit Steckanschluss Fabrikat Auer in Labtest Pr fkopf 161 052 Adapter DRSV Zur Aufnahme von berdruck LA mit Steckanschluss Fabr Dr ger und Fabr B amp R in Labtest Pr fkopf 161 059 Adapter SAS
6. Funktionsf higkeit Unbedingt beachten Wenn Vollmasken nach der Desinfizierung nicht 100 gesp lt werden und dadurch Desinfektions mittelr ckst nde auf die Latexhaut gelangen kann es bei einigen Desinfektionsmitteln zu Besch di gungen kommen Deshalb d rfen ausschlie lich Desinfektions mittel die frei von Phosphaten Al dehyden und Phenolen sind verwendet werden Zur Pflege d rfen keine l fett oder l sungsmit telhaltigen Mittel verwendet werden Diese sch di gen die Kopfhaut Als Pflegemittel wird von Labtec Silicon Spray empfohlen Die Lebensdauer des Pr fkopfes unterliegt nicht der Garantie Wenn die Latexhaut besch digt beraltert oder aus anderen Gr nden nicht mehr dicht ist so kann der Pr fkopf im Austauschverfahren gewechselt werden Bitte senden Sie den Pr fkopf ins Werk Sie erhalten umgehend einen Austauschkopf 6 Starting Up When the equipment is set up care must be taken to see that it is positioned so that it stands horizon tally and is well seated on all four bearing pads Once the mains transformer supplied with the ma chine is connected to a 230 V AC mains outlet the test stand is ready for operation T Care and Maintains The test stand does not need any special care but it should be protected from harmful external influ ences water damp in the form of steam dust To ensure that the test head lasts as long as pos sible it is important to carry out regular mainte nance
7. V Zur Aufnahme von berdruck LA mit Steckanschluss Fabr Sabre in Labtest Pr fkopf 161 068 Adapter ISSV Zur Aufnahme von berdruck LA mit Bajonett Fabr Interspiro Spiromatic P in Labtest Pr fkopf 161 069 Adapter EASV Zur Aufnahme von berdruck Lungenautomaten mit Einheits Steckanschluss DIN 58 600 136 020 Stoppuhr f r Dichtigkeitspr fungen 808 605 Silicon Spray Zur Pflege des Pr fkopfes Order no Description Explanation 161 027 _ Dustcap RD40 To seal breathing valve of NP full face masks with RD 40x 1 7 EN 148 1 161 028 Dustcap PE45 To seal breathing valve of HP full face masks with metric thread M 45x3 mm 161 032 Dust cap EAS To seal breathing valve of HP full face masks with universal plug in connector DIN 58 600 161 046 Adapter RD 40 To accept NP demand valves with RD 40x 1 7 EN 148 1 in Labtest test head 161 048 Adapter PE 45 To accept HP demand valves with metric threads M 45x3 in Labtest test head 161 051 Adapter AUSV To accept Auer HP demand valves with plug in con nectors in Labtest test head 161 052 Adapter DRSV To accept Dr ger and B amp R HP demand valves with plug in connectors in Labtest test head 161 059 Adapter SASV To accept Sabre HP demand valves with plug in connectors in Labtest test head 161 068 Adapter ISSV To accept Interspiro Spiromatic PHP demand valves with bayonet fittings in Labtest test head 161 069 Adapter EASV To accept HP demand valves with universal plug in connector DIN 58 600 136 020 Stop wat
8. cannot be expected unless the stand is operated and used exclusively as recommended in this manual Labtec accepts no liability for any personal injury or damage to property of any kind whatsoever or for any late squeal of such personal injury or damage to prop erty if the equipment has been used in a way that deviates from the instructions in this manual The same applies in the event of incorrect care and maintenance of the equipment and of incor rectly carried out repairs to it Labtec will recognize no claims under the guaran tee if the equipment has been operated main tained or repaired by persons who have not been specifically and correctly trained for these tasks and or original replacement parts have not been used in repair and maintenance work on the equip ment The same applies if any sealed parts have been opened without express approval from Lab tec In other respects Labtec GmbH terms of sale and conditions of supply and the company s terms of guarantee and warranty provisions apply These are in no wise extended by these notes 2 Description of the Equipment Labtest 400 is a test bench designed for use in testing full face masks as specified in EN 136 and also demand valves also pressure reducer of BA The test head is inflated from an intergraded elec tric pump 3 Specifications LP gauge 30 to 30 mbar by 0 2 mbar class 1 6 MP gauge O to 16 bar by 0 5 bar class 1 6 MP gauge O to 400 bar by 20 ba
9. ch For tightness tests 808 605 Silicon spray For treatment of test head 142 501 Testhead AC As replacement Accessories 16 28 032 161 046 048 161 051 au me 808 605 Labtec GmbH D 74927 Eschelbronn Fax 49 0 6226 1587300 e mail info labtronic de www labtronic de Seite Page 5 6 Inbetriebnahme Beim Aufstellen darauf achten dass das Ger t waagrecht steht und an allen 4 Auflagepuffern gut aufliegt Durch Anschlie en des mitgelieferten Netztrafos an einen 230 V AC Stromanschluss ist der Pr f stand betriebsbereit 7 Pflege und Wartung Das Pr fger t bedarf keiner besonderen Pflege Es sollte jedoch vor u eren sch dlichen Einfl ssen Wasser Feuchtigkeit in Form von Dampf sowie Staub gesch tzt werden Um eine m glichst lange Standzeit des Pr fkopfes zu erreichen muss dieser regelm ig gewartet und gepflegt werden Der berzug besteht aus Naturlatex Latex ist ozonempfindlich deshalb den Pr fkopf nicht in pralles Sonnenlicht stellen Bei l ngeren Stillstandszeiten am besten mit einem Tuch o abdecken Bei Verschmutzung diesen gut mit Seifenwasser Neutralseife abwaschen Es empfiehlt sich die Verwendung eines Mikrofasertuches Keine L sungsmittel verwenden Die Kopfhaut ist zwar u erst strapazierf hig und relativ dick kann aber durch spitze Gegenst nde verletzt werden und verliert damit ihre
10. ent head by return Labtec GmbH D 74927 Eschelbronn Fax 49 0 6226 1587300 e mail info labtronic de www labtronic de Seite Page 6 Konformit tserkl rung Certificate of Conformity Attestation de Conformite LE Bezeichnung der Maschine Pr fger t Type of machine Test Equipment Description de la machine Equipment de test Modell Model Modele Labtest Typ Type Type LT 400 Serien Nr Serial No No de serie Hiermit wird best tigt dass das Ger t den Anforderungen der Maschinenrichtlinie 89 392 EWG sowie der EMV Richtlinie 89 336 EWG Klasse A einschlie lich allen bis heute ver ffentlichen Anderungen bzw Nachtr gen entspricht Das Ger t entspricht folgenden Normen bzw Richtlinien We do hereby certify that the above mentioned product meets the requirements set forth in EEC Guideline 89 392 and EMC 89 336 Class A including all changes and addendums to date thereto The above mentioned product meets the following stan dards and guidelines Nous Vous Confirmons que l appareil cite ci dessus correspond aux exigences des directives 89 392 CEE ainsi ou a la directive CEM 89 366CEE Classe A ci inclus toues les modifica tions ainsi que tous les suppl ments publi s jusqu ce jour L appareil mentionn correspond aux nomes cit s ci apr s DIN VDE 0805 A1 Ausgabe dates en date du 1990 1991 DIN EN 135 Ausgabe dates en date du 1996 DIN EN 136 Ausgabe dates en date
11. r class 1 6 Dead space Approx 480 ml without adapter s Pump Approx 10 l min 24 V DC Power Transformer belongs to scope of supply 230 V AC 50 Hz 24 V DC Timing Stopwatch with LCD display selection of 1 to 99 min periods ca B 450 x H 500 x T 480 mm ca 15 kg Dimensions weight Abmessungen Gewicht Approx 450 x 500 x 480 WxHxD approx 15 kg Labtec GmbH D 74927 Eschelbronn Fax 49 0 6226 1587300 e mail info labtronic de www labtronic de Seite Page 2 4 Bedienelemente 4 Operation elements 15 56 7189 Legende Explanation Pr fkopf Test head mit Mess ffnung f r Druckmessung with opening for pressure measurement in mouth Niederdruckmanometer Low pressure gauge 30 30 mbar G teklasse 1 6 10 fache Uber 30 to 30 mbar class 1 6 10 fold safety for ex Unterdrucksicherheit cess and negative pressure Mitteldruckmanometer Medium pressure gauge 0 16 bar G teklasse 1 6 O to 16 bar class 1 6 Hochdruckmanometer High pressure gauge 0 400 bar G teklasse 1 6 O to 400 bar class 1 6 Pr fkopf leeren Tastventil Test head deflation button Durch Bet tigen wird Pr fkopf geleert Pushing this button opens a valve to empty the test head of air Exhalation Tastventil Exhalation button Pushing this button sets up a Durch Be
12. t tigen wird ein Vakuum Luftstrom von ca vacuum and causes a stream of air to flow in by 10 l min am Pr fanschluss und somit ein berdruck way of the test connection at approx 10 l min lead im Lungenautomaten bzw Maske erzeugt ing in turn to negative pressure in the demand valve or mask Druckentlastung Tastventil Pressure relief button Durch Bet tigen wird der Unter bzw berdruck Pushing this button causes high pressure to fall or abgesenkt negative pressure to rise Inhalation Tastventil Exhalation button Durch Bet tigen wird ein Luftstrom von ca 10 l min Pushing this button causes a current of air at am Pr fanschluss und somit ein Unterdruck im approx 10 l min at the test connection creating Lungenautomaten bzw Maske erzeugt excess pressure in the demand valve or mask Pr fkopf f llen Tastventil Test head inflation button Durch Bet tigen wird Pr fkopf gef llt aufgeblasen Pushing this button inflates the test head Pressluftatmer Anschluss Breathing apparatus connection Mitteldruck EURO Nippel Medium pressure EURO pin mail Lungenautomatenanschluss Demand valve connection Mitteldruck EURO Kupplung Medium pressure EURO coupling fee mail Labtec GmbH D 74927 Eschelbronn Fax 49 0 6226 1587300 e mail info labtronic de www labtronic de Seite Page 3 4 Bedienelemente 4 Operation elements Legende Explanation 12 Ger teanschluss 300 bar Connection for appliances 300 bar 1