Home
EasyScope User Manual
Contents
1. Customise Screen Colors Twochoices are available Print Screen Image prints out the Oscilloscope screen display only while Print Oscilloscope prints out the whole application screen including all the panels controls and menus Clicking on either of these will spool the selected image to the printer If you havemore than one printer available or you wish to change the printer properties settings reviewthe Printer Setup 2 topic before printing Printer Setup The image of the oscilloscope screen can be printed to any installed Windows printer Thisis done throughthe File Menu at the top of the application screen EasyS cope 1 0 File Screen Cursors Help SS 0004 Click on Screen to viewthe drop down menu below Illuminate Save Screen Image to File Setup Printer Print Screen Image Print Oscilloscope Load Background rom File Save Background to File Customise Screen Colors 2003 USB Ins truments com 3 15 Using EasyScope lfthere is more than one printer attached to the PC and you do not wish to printto the default printer then click on Setup Printer first to select which of the available printers you would like to use This brings up the standard Windows Print Setup dialog shown below Print Setup 7 EPSON Stylus COLOR JBD Properties Status Default printer Ready Type EPSON Stylus COLOR 980 Wher LPT Comment Paper Size jaq 2106 297 mm rentat
2. 5 1 5 1 1 5 2 Appendix Error Messages FTD2XX DLL Not Found If when trying to run the EasyScope Application forthe first time you get an Error Starting Program message as shown below the reason is that you havenot yet installed the USB drivers For information about installing the driversread the Installing the USB Drivers 10 section then plug your hardwareinto a spare USB Port Error Starting Program AN A required DUT tile FT O24 LILL was nat found Device Not Found Error Ifthe following message is displayed when the Run Stop or Single button is clicked the probable cause is that the USB Oscilloscope hardwareis not connected to the computer Check the hardware connection to USB Ifyou are connected to a self poweredUSB hub make sure it is poweredup Error GA GetFT DeviceSenalNo Device Not Found Uninstalling The Software and Drivers From the Start gt Programs gt EasyScope menu on the Windows Toolbal select the Uninstall Option and click on it E EasyS cope Help F EasyS cope This will start the uninstaller program The following confirmation screen will appear 2003 USB Instruments com Uninstalling EasyScope 1 0 Q pve No Ifyou are sure you want to uninstall the EasyScope Program and USB drivers click on Yes If not click on No to abort the Uninstall process Clicking on Yes brings up the following confirmation screen for the Uninstallation of the
3. hl D Color Basic colors IC ustom colors ll mMNNNNS ll 8888 ll tm CH ll SEES ll RREN EE E EI Define Custom Colors gt Cancel Ifyou require more than basic colours shown click on Define Custom Colors to choose froma wider selection Once you have made your selection click on the OK button to set the colour for the chosen item An example of an Oscilloscope Screen using alternativeuser defined colours is shown below 2003 USB Instruments com Using EasyScope EEN Stopped MIEN IN pri cl L i TAL MIN HAA iM ME TM MV Vert A LI 0 038 Ga Sec 200 000 C2 1 310 TDi 0 00020 Sec Delta 1 350 YD 405 BOS 3 16 Customising the Background The background image background colour plus grid of the oscilloscope screen can be savedto a Windows BMP format file customised viaa BMP editor such as Paint Paintshop Pro etc with custom text logos etc and re loadedinto the application This is done throughthe File Menu at the top of the application screen EasyS cope 1 0 File Screen Cursors Help S WA Click on Screen to viewthe drop down menu below Illuminate Save Screen Image to File Setup Printer Print Screen Image Print Oscilloscope Load Background from File Save background ta File Customise Screen Colors 2003 USB Instruments com am EasyScope User Manual Click on Save Background to File to savethe bac
4. 15 Settings Timebase 13 Settings TriggerFunctions 17 Settings XY Mode 21 Setup Printer 26 Single Shot Capture 12 Software Installation 5 Specification 4 T Time Measurement 19 TimeBase Settings 13 TriggerFunctions Settings 17 U Uninstalling the applicationsoftware 36 Uninstalling the USB drivers 36 User Screen Full Size 3 Using EasyScope 12 13 14 15 16 17 18 19 21 22 V Voltage Measurement 18 _X XY Mode 21 2003 USB Instruments com
5. AND the trigger level of the selected channel is within 2003 USB Instruments com 3 2 Using EasyScope the voltage range of the input signal Tigger Auta SE CHE When the Run button is clicked the capture displav begins and the caption of the button changes to Stop The Single button is greyed out as the two functions are mutually exclusive To stop the capture click onthe Stop button andthe oscilloscope will change back into idle mode aen The last captured data will remain displayed on the screen as long as the user does not change any of the oscilloscope settings If desired the screen display can be saved to a Windows Bitmap bmp format file or can be printed by any printer connected to the P C These subjects are dealt with in later topics An alternativeto the Run Stop button is providedthrough the File Menu at the top of the application screen EasyS cope 1 0 File Screen Cursors Help SS SS Click on File to select the drop down menu below Click on Run or Stop as desired TimeBase Settings The timebase settings are adjusted by clicking on the rotary switch in the Timebase Panel Thereare 14 possible settings rangingfrom 50us per division fastest to 1sec division lowest Please note at the lower speed settings there will be a noticeable delay between clicking onthe Run button and the trace appearingon the oscilloscope screen This is because the sampling
6. B WT a a E ir ke ESA A Finally select if you wish to place a shortcut icon on the Windows desktop to the EasyScope programand click on OK The installation process is now complete If you haveselected this option you can launch the EasyScope program from the desktop by double clicking on the EasyScope icon pictured below hd basnscope You can also launch the EasyScope program from the Start gt Programs gt EasvScope menu on the Windows Toolbar E E Fa si cco pe kal d As shown above vou also have access to the EasyScope Help File and Program Uninstaller from there Before using EasvScope the USB drivers need to be installed This is done bv plugging in the 2003 USB Instruments com 710 EasyScope User Manual 2 2 instrument into a spare USB Port on the PC The instrument should be plugged into a USB hub port of your PC or alternatively a self poweredUSB hub one that has it s own power supply If the instrument consumes under 100mA check the specification you may also plug it into a bus powered USB Hub if desired Ifthis is the first time that the instrument has been plugged in Windows will then request the USB drivers for your product See Installing the USB Drivers 1 for further details Installing the USB Drivers Before using EasyScope the USB driversneed to be installed This is done by plugging in the instrument into a spare USB Port on the P
7. USB drivers FIDI D28 Uninstaller Version 2 1 If your USB Oscilloscope is still connected please unplug it now Click on Continue to uninstall the USB Drivers FIDI D28 Uninstaller Version 2 1 LG UMHE After the USB drivers havebeen uninstalled you should see the above screen Click on Finish to proceedto the uninstallation of the EasvScope Application software This will bring up the following screen 2003 USB Instruments com ER EasyScope User Manual Se Uninstalling EasyScope 1 0 Deleting Registry settings Deleting files Waiting for the process to finish Uninstallation was successfull The following files were created before or after the installation ou or other pour applications may need them L Prograrn Files E 3515 cope 1 055 ereensili5 Bright bmp C Program Files E asyS cope 1 0 5 creens 0 5 Hormal bp Delete Delete All Close When the EasyScope Software is run forthe first time it automatically creates an INI file easvscope ini to store program settings and two BMP files DSBright omp and DSNormal bmp containing the images of the Normal and Bright screen themes It is safe to delete these Inthe course of using EasyScope the user may have savedsome screen images and should decide if they want to keep these or not After deleting any unwantedfiles click on the Close button to finish the un install procedure 2003 USB Instruments com Ind
8. and relative magnitude on the Y Axis The results of the FFT are automatically scaled so that the frequency with the highest amplitude equals 100 ofthe Y Axis It is possible to change this scaling manually by clicking onthe Man button for that channel and using the Up Down button to re scale the Y Axis manually The display can show either channelor both channels simultaneously by clicking on the CHA CHB LED buttons to enable or disable the display of that channel For each channel two cursors dashed lines are providedfor measuring the Frequency and displaying it in an informationbox at the bottom of the display To the top of the cursors are marker blocks 1 and2 Tomovea cursor place the mouse pointer overthe marker block you wish to move and holding down the left mouse button drag the cursor to the point you wish to measure The aboveFFT display shows a 1kHz square waveinput on channelA Being a square wave the harmonics can clearly be seen Inthis example it is difficult to measure the frequency accurately as the X Axis stretches from zero to 100kHz The X Axis scaling depends on the sampling frequency of the oscilloscope Inthe abovecase the Oscilloscope timebase was set to 200us division which corresponds to a sample rate of 200 000 samples sec To zoom in on the 1KHz peak we will adjust the timebase on the main application screen to 20ms div which corresponds to a sampling rate of 10 000 samples sec The FFT display no
9. conversion rate is low and it takes more time to capture a buffer s worth of data 2003 USB Instruments com IN EasvScope User Manual 3 3 TimeBase T Div dUlms The timebase setting can change the sampling rate of the oscilloscope Thesampling rate is displayed on the bottom right of the oscilloscope panel see below Sa Sec 200 000 T Div 0 00020 Sec MDH AJ B Offset Settings Ground Reference The ground Ov reference for each channel is shown by a small arrowon the left hand side of the screen The colour of the arrowis the same as the colour of the trace for that channel Toadjust the ground reference setting click on the Up Down buttons in the Offset Panel There are one set of buttons foreach channel see below Theoffset can be changedboth in idle mode andin run mode 2003 USB Instruments com 3 4 3 5 Using EasyScope 15 Selecting the Channel The oscilloscope has two channels named CHA and CHB These can be turned on and off by clicking on the two LED switches on the main panel When a channelis enabled the LEDs will be lit otherwise they will be dimmed One or both channels must be enabled to viewthe oscilloscope trace Inthe example below CHA is enabled and CHB is turned off B CHA B 10 SE al BIH I SP LU LI 85 Adjusting the Input Gain The input gain is adjusted by clicking on the Volts Div rotary switch on the main panel below Two sw
10. from If you do not use to use triggering select Auto instead and the oscilloscope trace will free run Next select which edge of the signal you wish to trigger from ve selects a rising edge while ve selects a falling edge Use the TrigLevel Up Down button to set the desired trigger level voltage The trigger level is shown as an arrowwith a T to the right of the oscilloscope screen Finally use the 10 50 90 switch to select the position of the triggerredeventon the screen Inthe following examples we select to trigger from CHA on a rising edge Example 1 Trigger position set to 50 Inthis example the trigger point the rising edge of the waveform is set to the centre of the oscilloscope screen display Example 2 Trigger position set to 10 Inthis case the trigger is displayed towards the left side of the oscilloscope screen display 2003 USB Instruments com 8 EasyScope User Manual 3 8 Example 3 Trigger position set to 90 Inthis case the trigger is displayed towards the right side of the oscilloscope screen display Voltage Measurement EasyScope supports two pairs of cursors one for each channel for measuring amplitude Theseare enabled disabled by two buttons on the bottom panel When a cursor is enabled a pair of measurement cursors dashed horizontal lines appear onthe screen To the right of the cursors are marker blocks 1 and 2 To movea cursor place the mouse pointer o
11. of each theme can be customised to the user s own preference See the Changing the Screen appearancesection for details of how to customise the theme colours Illuminate This is the default Normal colour theme The backgroundis black the grid is green CHA is shown in yellow and CHB is displayed in fuscia 2003 USB Instruments com Using EasyScope 23 Ga sec 200 000 T Div 0 00020 Sec DOW Ai Bid BE This is the default Bright screen Thegrid colour changes from green to lime colour giving an effect similar to the illuminate button on a traditional oscilloscope 2003 USB Instruments com o EasyScope User Manual Gta D Ga sec 200 000 TDi 0 00020 Sec VdDwv AT B10 3 12 Quitting the Application There are two ways to shut downthe EasyScope application Thefirst of these is to click on the small X button on the top right of the application screen MA The other way to quit the application is through the File Menu at the top of the application screen EasyS cope 1 0 File Screen Cursors Help Click on File to select the drop down menu below w Stop Exit Click on Exit to quit the application 2003 USB Instruments com Using EasyScope 3 13 Saving the Screen Image The image of the oscilloscope screen can be savedto a Windows BMP format file This is done through the File Menu at the
12. only a right of limited use as M agree with the above terms and conditions Ifyou agree with the terms andcondiions of the License Agreement check the I agree box and click on the Next button to continue the installation process else click on the Exit button The Next button is disabled if you do not agree to the terms and conditions Agreeing to the terms and clicking on the Next button brings up the following screen 2003 USB Instruments com e EasyScope User Manual Fu Installing EasyScope 1 0 Destination Directory C Program Files E asyS cope 1 0 Required 1663 K Available 1878944 K BIOWSE Select the directory you wish to install the EasyScope software into A default directory is shown on the screen Unless you have good reason to change it we suggest you use the default suggested by the installation program Click on the Start button to commence copying the files to the EasyScope program directory Fa Installing EasyScope 1 0 Installation was completed successtully 100 A progress screen above will appearas the files are installed After a few seconds you should see the Installation completed successfully message Click on the OK button to complete the final stage ofthe installation process 2003 USB Instruments com Installing EasyScope 9 GH Installing EasyScope 1 0 e El SS es ja Lk ke d a ae MA MAR me F p iF p i H
13. 020 Sec Delta 1 380 Delta 6 650 U AOS Be 2003 USB Instruments com 4 EasyScope User Manual 1 3 Screen Function Overview The EasyScope screen is split into severalfunctional areas as shown in the picture below The sections that follow illustrate how to use the settings to control the functions of the instrument TirmeBase T Div TimeBase seg Di Settings og 4 7 ine o Toma Valtu biv Trigger Trigger 218 Auto S Settings D illi 20 CHA wD ato Se io CP amp RON Frag L Capture Stop Buttons Input Voltage On Screen settings Cursor 1 4 EasvScope Specification EASYSCOPE FEATURES e Attractive easy to use visual display e Single and Dual Channel Display modes e Sweep and XY display modes e F F T Fast Fourier Transform display e TimeBase from 50uS Divto 1 0 sec div e Input Ranges from 0 1v divto 5v div e O S D Markers for voltage measurement 2 sets e O S D Markers for time frequency measurement e Save Oscilloscope Screens to Windows BMP files e Screen Printout Facility e AC DC coupling support e Support forx1 x10 probes e User DefinedOscilloscope Display Colour Themes 2003 USB Instruments com Installing EasyScope 5 2 Installing EasyScope 2 1 Installing the Software Before connecting the instrument to the PC insert the supplied installation disk into the CD ROM driveof your PC The following menu will appear after a few seconds Cli
14. 29 C2 0 00729 Freq 1 An alternativeto using the lower panel buttons is to click on the Cursors setting in the top menu and click onthe item you wish to enable or disable w Horizontal Vertical CHA Vertical CHB 2003 USB Instruments com Using EasyScope 21 3 10 XY Mode Easyscope has the capability of displaying in XY mode as well as sweep mode XY mode is used to compare the frequency and phase between two signals usually sine waves This kind of display is sometimes referredto as a Lissajous figure To change fromsweep mode to XY mode click on the XY button on the bottom panel The followingexample shows two identical sine waveson each channelin sweep mode Ga sec 200 000 TDi 0 00020 Sec Viv A BID BEES Clicking on the XY button changes the display to XY Mode Thescreen now looks like 2003 USB Instruments com 22 EasyScope User Manual 3 11 Ga sec 200 000 TDi 0 00020 Sec Vi Fi i d As both the waveformsare identical XY mode just produces a straight line at 45 degrees More interesting effects can be obtainedwhen the signals are out of phase an ellipse appears or when the frequencies are different an ellipse with a number of twists in it appears Screen Colour Themes EasyScope supports two differentcolour themes Normal and Bright Thetwo themes are toggled by clicking on the Illuminate button on the bottom panel The colours
15. C The instrument should be plugged into a USB hub port of your PC or alternatively a self poweredUSB hub one that has it s own power supply If the instrument consumes under 100mA check the specification you may also plug it into a bus powered USB Hub if desired Ifthis is the first time that the instrument has been plugged in Windows will then request the USB drivers for your product Windows will request the USB drivers for your product and will display a Add New HardwareWizard dialog box The examples below are for Windows 98 but the procedureis very similar for other Windows versions Add New Hardware Wizard This wizard searches for new drivers for LIS 2200E A device driver is a software program that makes a hardware device work Cancel Click on Next to bring up the following dialog box 2003 USB Ins truments com Installing EasyScope Add New Hardware Wizard What da wou want Windows to do Ce Search for the best driver for pour device Recommended C Display a list of all the drivers in a specific location 0 you can select the diver you want back Cancel Click on Next to bring up the following dialog box Add New Hardware Wizard Windows will search for new divers in its diver database on your hard drive and in any of the following selected locations Click Mest to start the search Floppy disk drives Jk CO ROM drive Microsoft Windows Upda
16. EE 5 2_ Installing the USB DriverS cccccsccsceeeeseeeeeeeeeeeeneeeeeeeeeonsesseeensenseesnsonseeeneonees 10 Part Ill Using EasyScope 12 1 The Run Stop and Single Capture Buttons ss sssnennnnennennennennenzennennennenzen 12 2 aaa WANN ASE el E 13 3 Offset Settings Ground Reference LL ss nnennnnnnnnennnnnnnnnnnnnnennrnnennnnnnnnznnnn zz 14 A 1 2vpelectin the Channel si aieiiieiiitoi torrent ia eko konna dit i 15 5 sadjustin the Input Gain iii ikessa sa bj a a 15 e wiv AC DC GOO PI A dad E 16 Z xs SING ING Trigger FUNCTIONS edu eeegegEeteee eege 17 8 Voltage Measurement ee REENEN ENNEN REENEN A EM EM AR ENNEN REENEN 18 H lime Frequency Measurement ccccesceceseeceeeneeeeneeeeeenseeeaseesnseeeneesonensonenees 19 10 KY MOE et 21 11 Screen Colour THEME Sea i nnmnnn nnen 22 12 sc QUITTING the Application iii nnmnnn 24 13 Saving the Screen Image si ie ei i 25 14 Printing the Screen Tu e LEE 26 Panter SEMI taa ira i EES S E a A Seaveeisie 26 15 Customisingthe Display Colours cscceceeeeeeeeeeeeeeeeeeeeeseeseeseeseeseeseeseeseesees 27 16 Customising the Background ccccccceeeeeceeceeeeeeeenseseeeesenseeeeeonseeseeonsenseeenenes 29 IL eNe MENUS tie aa a a 31 Part IV Using the FFT Display 31 i is a ei BR TE e E 31 2 a SAVINO NEE W 33 See Printing UNG o o WE 34 wu GlOSING Me FFT DISPIA i ii i a i ad 34 S cess UID EFT ODUGN EE 35 Cha
17. ane MIA A la bi L JJIPIDJIDIIJ SEI CET f Mi VT tf TA eA DS2200C User Manual Copyright c EasySync Ltd 2003 EasyScope User Manual 2003 USB Instruments com All rights reserved No parts of this work may be reproduced in any form or by any means graphic electronic or mechanical including photocopying recording taping or information storage and retrieval systems without the written permission ofthe publisher Products that are referred to in this document may be either trademarks and or registered trademarks of the respective owners The publisher and the author make no claim to these trademarks While every precaution has been taken in the preparation ofthis document the publisher and the author assume no responsibility for errors or omissions or for damages resulting from the use of information contained in this document or from the use of programs and source code that may accompany it Inno event shall the publisher and the author be liable for any loss of profit or any other commercial damage caused or alleged to have been caused directly or indirectly by this document Contents I Table of Contents Part Introduction 3 Ti ee Welcome to Ee DEE EE Eegeg 3 E UNI SIZE Screen Mage ai ie iii iii er A aE 3 d oereen FUNCTION ee TEE 4 4 crc EASY SCOPE Specification sivevesestewrsdcccurwercusesvesesevautisdunnancesnaveedusncuscenwaaweiwiveevenseunc 4 Part Il Installing EasyScope 5 g seas installina te
18. ck onthe Install EasyScope 1 0 button to launch the EasyScope installation program tallation CD EFasyScope 1 0 Ins Click on the Install EasyScope 1 0 button to launch the EasyScope installation program The following screen will appear 2003 USB Instruments com 6 EasyScope User Manual PA Installing EasyScope 1 0 English f English French Fran ais Geman Deutsch Italan fltaliana Spanish Espa ol Choose the language you would like the setup program to use In this example we will select English Click on the Next button to bring up the License Agreement Screen 2003 USB Instruments com Installing EasyScope Ful Installing EasyScope 1 0 To proceed with the installation you must accept this License Agreement Please read it carefully Copyright IL 2003 by EasySyre Ltd git AE GEN BEFORE PROCEEDING WITH THE INSTALLATION AND USE OF THIS SOFTWARE CAREFULLY READ THE FOLLOWING TERMS AND CONDITIONS OF THIS LICENSE AGREEMENT AND LIMITED WARRANTY The Aoreement l E wes kt BY INSTALLING OR USING THIS SOFTWARE VOU INDICATE YOUR ALLEFTAMLE OF THIS AGREEMENT IF YOU DO NOT ACCEPT OF AGREE WITH THESE TERMS F DU May NOT INSTALL OR USE THIS SOFTWARE ATT Tali III TI LICENSE This software including documentation Software is owned by EasySunec Ltd EasySunc This Agreement does not provide you with title or ownership of the Software but
19. ex Index _F Features 4 A FFT Closing the display 34 FFT Printing 34 AC DC Coupling 16 FFT Spectrum 35 FFT Display Overview 31 B File Menu Cursors 18 19 File Menu Exit 24 Bright ColourTheme 22 File Menu Run 12 File Menu Screen Options 22 25 27 29 C File Menu Stop 12 Frequency Measurement 19 Changingthe Display Background 29 Functional Overview 4 Changingthe Display Colours 27 ChannelSelection 15 Colour Themes 22 8 G 8 Cursors Horizontal 19 Ground Reference Settings 14 Cursors Vertical 18 H Help Menus 31 D Display Background Changing 29 Display Colours Changing 27 l DLL Not Found Error 36 7 7 Driverinstallation 10 Illuminate Button 22 Input Gain Adjusting 15 E Installalling the Software 5 Installing the Drivers 10 Error Starting Program 36 Introduction 3 4 2003 USB Instruments com wm EasyScope User Manual S 25 33 Measurement Frequency Measurement lime Measuring Amplitude N Normal Colour Theme O Offset Adjustment 14 Overview FFT 31 P Printer Setup 26 Printing Screen Image Q Quitting the Application R 19 18 22 26 34 24 Run Stop Capture 12 S Saving Screen Image Screen Colour Themes Screen Image Printing 29 33 22 26 34 19 creen Image Savingto File Settings AC DC Coupling 16 Settings Channel Selection 15 Settings Ground Reference 14 Settings Input Gain
20. ftware was installed check on the USB Instruments Web Site to see if there is a newerversionof the application software or help file available for download By clicking on On Line User Manual you can viewthe latest version of the Help File on line using your web browser If you haveanv problems viewing the On Line User Manual check your browser settings to make sure that javascriptis enabled By clicking on On Line F A Q you can view the support Frequently Answered Questions on line using your web browser If you experience any problems please check here first before contacting support If you cannot find the answer to your query then Click Here l to e mail product support If you haveanv problems viewingthe On Line F A Q check your browser settings to make sure that javascriptis enabled 4 Using the FFT Display 4 1 FFT Display Overview while a normal Sweep oscilloscope display can be used to display waveformsin terms of time it is also possible to display the input waveformsin terms of frequency and magnitude by using a FFT Fast Fourier transform algorithm on the input data To enable FFT display on EasyScope click on the FFT button on the lower panel FFT This will bring up a second application window containing the FFT display of the input waveforms 2003 USB Instruments com 32 EasyScope User Manual DS2200C FFT Display File FFT Window Spectrum UHz 100 000 Hz The FFT displays frequency on the X Axis
21. ion Portrait Source Sheet Feeder bi fe Landscape Cancel After changing the printer propertiesas desired click on OK to select the new settings Customising the Display Colours The display colours of the oscilloscope screen theme Normal or Bright can be changedfrom the default coluurs to suit the user preference Once changed the theme colours are saved and will be restored on subsequent launces of the application Changing the screen colours is done through the File Menu at the top of the application screen EasyS cope 1 0 File Screen Cursors Help SSS SH Click on Screen to viewthe drop down menu below Illuminate Save Screen Image to File Setup Printer Print Screen Image Print Oscilloscope Load Background from File Save Background to File Customise Screen Colors H 2003 USB Instruments com EN EasyScope User Manual Placing the mouse cursor overthe Customise Screen Colours entry will cuse a dropdown sub menu to appearas follows Background Grid Show Ticks Channel A Trace Channel B Trace CHA Measurement Cursor CHE Measurement Cursor Timingi Frequency Cursor Test Font Marker Blocks Restore Default Colors Choose the screen item you would like to change fromthe sub menu and click on it to bring up the colour selection dialog Note the colours can be reset to their default values at any time by clicking onthe Restore Default Colors sub menu item
22. itches are provided the upper one sets the gain for CHA while the lower one sets the gain for CHB 2003 USB Instruments com me EasyScope User Manual 3 6 m cual m cual H oe T CEN m CHE CHE e l 10 0 EE Thereare 5 settings to choose from on each rotary switch In addition the settings dependson if the oscilloscope probe used is a x1 1M ohm input impedance or a x10 10M ohm input impedance Ifa x10 oscilloscope probe is used then enablethe X10setting forthat channel by clicking on it s X10 button This will re scale the switch and display cursor settings by a factor of 10 In this example CHA is using a x1 oscilloscope probe while CHB is using a x10 oscilloscope probe AC DC Coupling AC DC coupling is controlled by miniature relays inside the oscilloscope Toselect AC or DC coupling click on the AC DC selector switch for each channel This will instruct the oscilloscope to change the coupling from AC to DC or vice versa The current selection is highlighted in green to the right of the switch B CHA al 58 EB CHE D xi0 AL DC Ele Inthis example CHA is set to DC coupling while CHB is set to AC coupling 2003 USB Instruments com Using EasyScope Triggerfunctions are controlled by the controls on the right hand side of the main panel 37 Using the Trigger Functions Trigger Auto Touse triggering first of all select which channel CHA or CHB you wish to trigger
23. kground This brings up the Screen Save As Dialog box Thedefault folder for Screen background savesis the Screens folderin the application program main directory Do NOT overwritethe two default theme screens DSNormal bmp and DSBright bmp as thse are re created over written everytime the application is launched B test brp File name test bmp Save as type F BMP Mi Cancel Ze Inthis case we will savethe Normalscreen backgroundto file testi bmp We then edit testi bmp in this case to include a custom header then reloadit using the Load Background from File option The modified Oscilloscope screen now looks like this fuming LlSD Ins UMENTS COM Ga sec 200 000 TDi 0 00020 Sec UW Uh BOS Note When editing the BMP file do not alter the size of the image and do not change the file format 2003 USB Instruments com Using EasyScope 31 when saving the file Doing so can cause unpredictable results when running the application 3 17 Help Menus EasvScope providesbuilt in comprehensiveaccess to both local and On Line accessed via the Internet help Clicking on the Help item of the menu bar displays the following options HTML Help About U 5E Iristrumenta Web Site On Line User Manual On Line F A Q Clicking on the HTML Help option brings up the local help screen in Windows Compiled HTML CHM format If it has been some time since your application so
24. ng time frequency Note Frequency can also be measured in a differentway using the FFT display To enable the time measurement cursors click on the Cur Horiz button Cur Horiz E When a cursor is enabled a pair of measurement cursors dashed vertical lines appear on the screen At the top of the cursors are marker blocks 1 and 2 To movea cursor place the mouse pointer overthe marker block you wish to move and holding down the left mouse button drag the cursor to the point you wish to measure A cursor informationpanel is displayed at the bottom of the oscilloscope screen showing the time value of each cursor and the difference 2003 USB Instruments com om EasyScope User Manual Horz C1 0 00079 ECRIRE Delta 0 00050 Todisplav the delta as a frequency click on the highlighted display area Horiz Cle O 00079 C2 i 0 00129 Freg 2000 00 ben mm Tel e The cursor information panel will now display the delta as frequency instead of time In this case the frequency is 2 000 HZ The followingexample uses the time measurement cursors to measure the frequency of the calibration reference output of a DS2000 oscilloscope Cursor 1 is placed on the first falling edge of the waveformand Cursor 2 is placed on the next falling edge of the waveform Looking at the cursor information panel in frequency mode we see that the frequency of the signal is in fact 1 000Hz or 1 0KHz Horiz LI iz 0 000
25. nging ihe FRI WinGOW breet AE EENS 35 2003 USB Instruments com EasyScope User Manual 35 Part V Appendix 36 d weng MON MGS e E 36 FTD2XX BEL Not Found nueu ccs saunu nune sune eene oono booo muna mnnn ene one moon tunn muna mene veee eoon tone muna wnn meet ene meoo muaa wene mewe veee ee 36 Devi e Not Found ENOT ssis aa a aa aa adaa NE Aa AAN iia a EAN aai AEAEE EEE AEE Ees 36 2 Uninstalling The Software and Drivers csccseeseeseceeeeeeeeeeeeeeseeeeeseeseeseeees 36 Index 39 2003 USB Instruments com Introduction 3 1 Introduction 1 1 Welcome to EasyScope EasyScope is the easy to use but powerful Digital Sampling Oscilloscope application program for the USB Instruments range of PC Oscilloscopes It runs on any USB 1 1 or USB 2 0 equipped PC using Windows 98SE 2000 ME and XP 1 2 Full Size Screen Image This is a viewofthe EasyScope application screen with all the cursors and information displays enabled For a detailed explanation of how to use the controls buttons and menus visit the Using EasyScope section EasvScope 1 0 Eile Screen Settings Cursors Help Running 1 TimeBase T Div Volts Div 10 0 I l 4 t I l l l I l l l I d l l I l 4 l I l l I l l l l I l l 4 F we zi e breng e e e ze zl e e ze ss L ze e e e e e e ze zi zs ka e Horiz C1 0 0004 YetA C1 0 688 Ye b LI 3 230 DadGer C2 e 0 00082 C2 a 0 688 C2 3 400 T Div 0 00
26. rinted to a Windows printer This is done through the File Menu at the top of the application s FFT screen D522 File FFI Window Spectrum Click on File to viewthe drop down menu below Save As Click on the Print menu selection This will spool the FFT image to the currently selected Windows printer Closing the FFT Display Toclose the FFT Display windowclick on the small x at the top right of the application s FFT Display Window mE i Esc 2003 USB Instruments com 4 5 4 5 1 4 5 2 Using the FFT Display Other FFT Options Changing the FFT Window The FFT screen display can changedto use a number of different windowing algorithms DS2200C FFT Display File FFT Window Spectrum Click on FFT Window to view the drop down menu below W Rectangle Triangle Cos Gauss Hamming BlackM an The default window algorithmis Rectangle Others can be selected from the drop down menu if required Changing the FFT Spectrum The FFT screen display can changedto use a number of differentways of scaling the Y_axis These can be changed from the memu at the top of the FFT display screen DG 23 File FFT Window Spectrum Click on Spectrum to viewthe drop down menu below Power Magnitude HMG Haze The defaultdisplay algorithm is Magnitude Others can be selected fromthe drop down menu if required 2003 USB Instruments com ER EasyScope User Manual 5
27. te lt back Cancel i Check CD ROMdrive and un check any other options NOTE If the CD is not availableand the EasyScope software has already been installed then check the Specify a location box and use the Browse button to select the drivers sub directory of the EasyScope Program Files directory instead Keep Clicking on Next until the installation is finished as per the screen below 2003 USB Instruments com 12 EasyScope User Manual Add New Hardware Wizard 3 1 DS22000 Oscilloscope Windows has finished installing the software that your new hardware device requires Cancel Click Finish and the driverinstallion is now complete Using EasyScope The Run Stop and Single Capture Buttons On starting EasyScope the programis in idle mode and displays two buttons on the bottom toolbar with the captions Single and Run In order to display a trace on the Oscilloscope you need to click on either of the Run or Single buttons The Run button is used to continuously capture and display data while the Single button captures one screen s worth of data then returns the program to idle mode On clicking the Run or Single buttons captured data will be displayed on the screen providingthat e One or Both of the channels are enabled AND Triggeringis in auto mode no triggering Trigger Aut E OR AND OR AND e Triggeringis enabled on one of the channels
28. top of the application screen EasyS cope 1 0 File Screen Cursors Help Click on Screen to viewthe drop down menu below Illuminate Setup Frinter Print Screen Image Print Oscilloscope Load Background from File Save Background to File Customise Screen Colors Click on the Save Screen Image to File menu selection This will bringup the Save As dialog box By default screen images are savedin the Images folder of the main application folder the folder the EasyScope application was installed into A differentfoldercan be selected if desired Either enter a new file name in the box providedor click on an existing file name if you want to overwriteit with the new image A ole Ces Dave jr Images fred brp Save as type Bitmaps D bmp Cancel Ze Click on Save to savethe screen image to a file or Cancel to quit without saving and return to the application 2003 USB Instruments com e EasyScope User Manual 3 14 3 14 1 Printing the Screen Image The image of the oscilloscope screen can be printed to any installed Windows printer Thisis done throughthe File Menu at the top of the application screen EasyS cope 1 0 File Screen Cursors Help ee Click on Screen to viewthe drop down menu below Illuminate Save Screen Image to File Setup Printer Print Screen Image Print Oscilloscope Load Background rom File Save Background to File
29. verthe marker block you wish to move and holding down the left mouse button drag the cursor to the point you wish to measure When a cursor is enabled the measurement information for that cursor is displayed in an information block at the bottom ofthe trace display as shown below CI 0 500 Ver B C1 11 800 C2 e 1 100 C2 m 11 300 Delta 0 600 Delta 23 000 C1 and C2 are the Cursor 1 and Cursor 2 values relative to the Ground Setting offset for that channel Thedifference in amplitude C1 minus C2 is shown by the Delta value The following example shows the cursors being used to measure the peak to peak amplitude of a signal in this 2003 USB Instruments com 3 9 Using EasyScope mm case the 1KHz 1 25v square wavereference output of a DS2200 oscilloscope The measurementcursors are placed one on the top the other on the bottom of the waveform Vert A LI 1 250 C2 e 0 000 Delta 1 250 As can be seen from the information display Cursor 1 is sitting at 1 25vand Cursor 2 is sitting at Ov relative to the Channel GND The peak to peak amplitude is shown by the Delta value in this case 1 25 volts An alternativeto using the lower panel buttons is to click on the Cursors setting in the top menu and click onthe item you wish to enable or disable w Horizontal Vertical CHA Vertical CHB Time Frequency Measurement EasyScope supports a pair of horizontal measurement cursors for measuri
30. w looks like this 2003 USB Instruments com 4 2 Using the FFT Display 33 DS22000 FFT Display File FFT Window Spectrum Hz a 500 Hz Freg 4 LI 996 C2 2 998 Delta 2 002 By movingthe measurement cursors we can see that the main frequency is shownas 996 Hz and the next harmonic is at 2998 Hz which given the measurement resolution of the cursors is as close as we can get to the true values of 1 000 Hz and 3 000 Hz Saving the FFT The image of the FFT screen can be savedto a Windows BMP format file This is done through the File Menu at the top of the application s FFT screen DS2200C FFT Display File FFT Window Spectrum Click on File to viewthe drop down menu below Click onthe SaveAs menu selection This will bring up the SaveAs dialog box By default screen images are savedin the Images folder of the main application folder the folderthe EasyScope application was installed into A differentfoldercan be selected if desired Either enter a new file name in the box providedor click on an existing file name if you want to overwrite it with the new image 2003 USB Instruments com a EasyScope User Manual 4 3 4 4 Save ire E Images 7 Al ce fred bmp Save as pe Bitmaps bmp sl Cancel Ze Click on Save to savethe screen image to a file or Cancel to quit without saving and return to the application Printing the FFT The image ofthe FFT screen can be p
Download Pdf Manuals