Home

Manuale HDM + Profibus

image

Contents

1. Reset button Pulsante di reset Selettore rotativo delle decine per l indirizzamento del nodo Oy Selettore rotativo delle unit per l indirizzamento del nodo Interruttori per l inserimento delle resistenze di terminazione Leds di segnalazione 2 3 DIAGNOSTICA La diagnostica di un modulo HDM AS I definita dallo stato dei LEDs di interfaccia o Tenth selector for node addressing Unit selector for node addressing O Terminating resistance switches Indicator lights 2 3 DIAGNOSTICS The diagnostics of an HDM Profibus module is defined by the status of the interface lights LED Verde LED Verde LED Rosso LED Rosso SIGNIFICATO Green Power Green BUS Red BUS Red EXT MEANING Power ON BUS OK BUS error EXT fault ON light OK light error light fault light ON verde ON verde OFF OFF Il modulo funziona ON green ON green OFF OFF The module is operating O O O O correttamente O O O O correctly OFF OFF OFF OFF Il modulo non alimentato OFF OFF OFF OFF The module is not powered on O O O O O O O ON verde OFF ON rosso OFF Il modulo non comunica ON green OFF ON red OFF The module is not communicating O O O O con la rete O O O O with the network ON verde ON verde OFF ON rosso Manca l alimentazione ON green ON green OFF ON red No auxiliary power supply O O O e ausiliaria o si verificato O O O O or output failure un
2. interrupted the local signal is activated and the EXT FAULT light comes on as well as the Master error signal The signal resets automatically when the power lt comes back on If the maximum simultaneous current is exceeded the reset table fuse C cuts off power to the node o If this happens disconnect the power cable remove the In caso di superamento della corrente massima simultanea interviene il fusibile resettabile C che sconnette l alimentazione del nodo cause of the fault and then reconnect it Per ripristinare il corretto funzionamento scollegare il cavo di alimentazione rimuovere la causa del guasto e ricollegare il cavo di alimentazione y 4 ASSEGNAZIONE DEI BIT DI DATI AGLI OUTPUT NEL SINGOLO NODO 4 ASSIGNING DATA BITS TO THE OUTPUTS FOR EACH NODE bit 0 bit 1 bit 2 bit 3 bit 15 bit 0 bit 1 bit 2 bit 3 bit 15 Out 1 Out 2 Out 3 Out 4 Out 16 Out 1 Out 2 Out 3 Out 4 Out 16 4 1 INDIRIZZI DI USCITA DEI SOLENOID PER SINGOLO NODO ESEMPIO 4 1 SOLENOID OUTPUT ADDRESSES FOR EACH NODE EXAMPLE Valvola Valvola Valvola Valvola Valvola Valvola Bistable Monostable Monostable Bistable Bistable Monostable Bistabile Monostabile Monostabile Bistabile Bistabile Monostabile valve valve valve val
3. APN METAL amp WORK PNEUMATIC HDM PROFIBUS DP HDM PROFIBUS DP MANUALE D USO USER MANUAL Le valvole Heavy Duty Multimach Profibus DP consentono il collegamento di isole HDM ad una rete Profibus Conformi alle specifiche Profibus DP DIN E 19245 offrono funzioni di diagnostica e sono disponibili nella configurazione fino a 16 out 1 CARATTERISTICHE 1 1 ALIMENTAZIONE Per l alimentazione elettrica si utilizza un connettore M8 l alimentazione di potenza separata da quella del bus per cui in caso di allarme si pu disinserire la potenza mentre la linea bus resta attiva La mancanza di alimentazione di potenza viene segnalata dall accensione del led rosso EXT FAULT Il guasto viene segnalato inse che deve provvedere ad una adeguata gestione dell allarme 1 2 PROTEZIONI Lo slave protetto da inversione di polarit da sovraccarichi mediante un fusibile del tipo ripristinabile e i drivers di uscita integrano la protezione da cortocircuito di ogni singola valvola In caso di cortocircuito segnalato dall accensione dl led rosso EXT FAULT solo la valvola guasta viene disconnessa Il guasto viene segnalato al Master che deve provvedere ad una adeguata gestione dell allarme Dopo la rimozione della causa del guasto la segnalazione al master si resetta automaticamente mentre rimane attiva la segnalazione locale EXT FAULT per resettare l allarme si deve premere brevemente il pulsante di riarm
4. Peripheral defect diagnostics Defects signalled Module status in the event of a peripheral defect Data bit value Output status in the absence of communication DP PROFIBUS MODULE FOR HDM VALVES 3 24VDC 10 Slave protected by overload and polarity reversal Outputs protected from overloads and short circuits 500 mA Via rotary selectors 99 LED local signal and Master signal Output short circuit or overload No auxiliary power Profibus communication active The Peripheral Defect bit is active and accessible at the Master station 0 not active 1 active Inactive www metalwork eu ELZZZZ129 IM04_05 2012
5. guasto sulle uscite 3 INSTALLAZIONE E CONFIGURAZIONE DEL NODO Gli elementi per la lara e il ripristino del corretto funzionamento si trovano sotto il coperchio di chiusura Per accedervi svitare le due viti con una chiave esagonale da 2 5 mm A AVVERTENZE e Disattivare la tensione prima di inserire o disinserire i connettori pericolo di danni funzionali e Collegare il modulo a terra mediante un conduttore appropriato Eventualmente utilizzare per il collegamento uno dei fori di fissaggio libero La mancanza di collegamento a terra pu causare in caso di 3 NODE INSTALLATION AND CONFIGURATION The elements required for the configuration and resumption of correct operation are situated below the cover which can be removed by unscrewing the two screws using a 2 5 mm hexagonal wrench A WARNING e Power off the system before inserting or removing the connectors risk of functional damage e Earth the module using the correct wire Use one of the free holes if necessary Failure to earth the system properly may cause malfunctions and serious damage in the event of electrostatic scariche elettrostatiche malfunzionamenti e danni irreversibili e Utilizzare solamente unit di valvole completamente assemblate e Per l alimentazione utilizzare esclusivamente alimentatori a norma IEC 742 EN60742 VDE0551 con resistenza di isolamento minima di 4kV PELV 3 1 INDIRIZZAMENTO Prima di collegare uno
6. LEGAMENTO E SEGNALAZIONE 2 1 COLLEGAMENTI ELETTRICI PIEDINATURA CONNETTORI Connettore M8 per l alimentazione del nodo e delle uscite 1 24VDC alimentazione nodo Profibus 2 24VDC alimentazione ausiliaria valvole 3 GND 4 GND Connettori per la connessione alla rete Profibus BUS IN connettore maschio BUS OUT connettore femina 5VDC 5VDC 2 A 2 A ION JSIOVA 4 B 4 B 5 schermo 5 schermo A ATTENZIONE NON COLLEGARE PIN 1 e PIN 3 da utilizzare solo l alimentazione delle resistenze di terminazione esterne Heavy Duty Multimach Profibus DP valves can be used to link HDM islands to a Profibus network They comply with Profibus DP DIN E 19245 specifications feature diagnostic functions and are available with up to 16 outputs 1 FEATURES 1 1 POWER SUPPLY An M8 connector is used for the power supply which is separate from that of the bus which means the power can be switched off if there is an alarm while the bus line remains active The EXT FAULT red light comes on when the power supply is cut off The fault is relayed to the Master which must provide adequate alarm management 1 2 PROTECTIONS The Slave is protected against polarity inversion and overloads by a resettable fuse and output drivers provide extra short circuit protection for each valve Short circuits are indicated by the EXT FAULT red light In the event of a short circuit only the faulty valve is disconnected The fault is relay
7. Slave al sistema bus si consiglia di assegnargli un indirizzo non ancora occupato L indirizzo del nodo si configura impostando sui selettori rotativi delle decine E e delle unit F il numero desiderato 3 2 INSERIMENTO DELLE RESISTENZE DI TERMINAZIONE L ultimo nodo di ogni ramo della rete Profibus deve essere terminato con le apposite resistenze Questo per evitare errori di riflessione durante la comunicazione Master Slave che possono generare malfunzionamenti L inserimento si ottiene impostando su ON i due interruttori G A ATTENZIONE Per una migliore immunit ai disturbi mantenere la velocit di comunicazione pi bassa possibile compatibilmente con l applicazione specifica discharge Only use fully assembled valve units e Only use power supply units to IEC 742 EN60742 VDE0551 standards with a minimum insulation resistance of 4kV PELV 3 1 ADDRESSING Before connecting a Slave to the bus system it is advisable to assign it an address The node address is configured by entering the desired number on the selectors for tenths E and units F 3 2 ACTIVATION OF TERMINATING RESISTANCES The last node of each branch of the Profibus network must be terminated with the required resistances This is to avoid reflection errors during Master Slave communication which can generate malfunctions They can be activated by pressing ON on the two switches G A IMPORTANT To improve immunity to disturbance keep the c
8. ed to the Master which must proved adequate alarm management After the fault has been rectified the Master signal resets automatically but the local signal EXT FAULT remains active To reset the alarm press the reset button briefly or switch off the power supply The fuse and reset button are located under the rectangular cover The rotary switches for addressing and the dip switches for activating the terminating resistances are located under the same cover 1 3 CONNECTIONS The Bus connectors are M12 with type B coding in accordance with Profibus standards Pre wired Profibus cables available from the trade can also be used for connection in order to avoid malfunctions due to faulty wiring An M8 4 pin female connector must be used for connection to the power mains As an alternative to pre wired cables for the bus connection you can use M12 metal connectors in which the cable shield is connected to the body of the connector The BUS IN and BUS OUT connector shields are connected via the M12 threading of the metal cover of the module The Slave must be earthed This can be done using one of the threaded holes in the metal body not used for securing the dadi A WARNING e Failure to earth the Slave properly may cause malfunctions and serious damage in the event of electrostatic discharge e In order to guarantee the protection degree IP65 it s necessary that the exhausts are conveyed and that in case of no use the BUS OUT connector g
9. ets plugged 2 CONNECTING AND SIGNALLING ELEMENTS 2 1 ELECTRICAL CONNECTIONS CONNECTOR PIN CONFIGURATION M8 connector for powering the node and outputs 1 24VDC Profibus node power supply 2 24VDC auxiliary valve power supply 3 GND 4 GND Connectors for connection to the Profibus network BUS IN male connector BUS OUT female connector 1 5VDC 1 5VDC 2 A 25A 3 0V 3 0V 4 B 4 B 5 shield 5 shield A important DO NOT CONNECT PIN 1 and PIN 3 to be used only for feeding of the external terminating resistors APN METAL Neb WORK PNEUMATIC e Per una corretta comunicazione utilizzare cavi a norma Profibus con lunghezza minima di 1 metro e Lo schermo deve essere collegato alla ghiera Se ci non fosse possibile lo si pu collegare al pin 5 Entrambi questi metodi possono anche essere usati in combinazione 2 2 COLLEGAMENTO E CONFIGURAZIONE DEL NODO Connessione al bus Profibus DP Connessione per l alimentazione del nodo e per l alimentazione ausiliaria delle uscite Fusibile ripristinabile e For correct communication use Profibus cables at least 1 metre long e The shield should be evenly distributed around the thread Should this not be possible the shield can be connected to prin 5 Both of these methods can also be used in combination 2 2 NODE CONNECTION AND CONFIGURATION Connection to the Profibus DP bus The node and the output power connection Resettable fuse
10. o oppure si deve togliere alimentazione di potenza Il fusibile e il pulsante di riarmo delle uscite si trovano sotto al coperchio rettangolare Sotto lo stesso coperchio si trovano li switch rotanti da utilizzare per l indirizzamento e i dip switch per aes delle resistenze di terminazione 1 3 CONNESSIONI connettori Bus sono M12 con codifica di tipo B secondo la normativa Profibus per il collegamento si possono utilizzare anche cavi Profibus precablati reperibili sul mercato in modo da evitare i malfunzionamenti dovuti a cablaggi difettosi Per la connessione dell alimentazione si deve utilizzare un connettore M8 femmina 4 poli Per la connessione del bus in alternativa ai cavi precablati devono essere utilizzati dei connettori M12 metallici con il collegamento dello schermo del cavo al corpo del connettore Il collegamento dello schermo del connettore BUS IN a quello di BUS OUT effettuato attraverso la filettatura M12 del coperchio metallico del modulo Lo slave deve essere collegato con la terra per questo si pu utilizzare uno dei fori filettati del corpo metallico non utilizzato per il fissaggio dell isola A ATTENZIONE e La mancanza di collegamento a terra pu causare in caso di scariche elettrostatiche malfunzionamenti e danni irreversibili e Per garantire il grado di protezione IP65 necessario che gli scarichi siano convogliati e che il connettore BUS OUT in caso di inutilizzo sia tappanto 2 ELEMENTI DI COL
11. ommunication speed as slow as possible depending on the specific application 3 3 RESET DEGLI ALLARMI In caso di cortocircuito o sovraccarico di un uscita interviene il circuito di protezione che scollega l uscita difettosa mentre tutte le altre rimangono locale con attive Contemporaneamente viene attivata sia la segnalazione l accensione del Led EXT FAULT che la segnalazione al Master La segnalazione al Master si resetta automaticamente alla rimozione del guasto Per resettare la segnalazione locale EXT FAULT necessario premere il pulsante di reset D posizionato sotto il coperchio oppure togliere l alimentazione di potenza 24Vdc valvole In caso di interruzione dell alimentazione ausiliaria delle uscite viene attivata sia la segnalazione locale con l accensione del Led EXT FAULT che la segnalazione di errore al Master La segnalazione si resetta automaticamente al ripristino dell alimentazione 3 3 ALLARM RESET In the event of an output short circuit or overload the safety circuit disconnects the output but all the others remained active At the same time the local signal is activated and the EXT FAULT light comes on as well as the Master signal The Master signal resets automatically when the fault has been rectified To reset the EXT FAULT local signal press the reset button D under the cover or power off 24Vdc valves If the auxiliary power supply to the outputs is
12. ve _ valve valve Out 1 Out 3 Out 4 Out 5 Out 16 Out 1 Out 3 Out 4 Out 5 Out 16 Out 2 Out 6 Out 2 Out 6 La mappatura degli indirizzi in funzione della configurazione del Master 5 DATI TECNICI Per le caratteristiche generali vedi la descrizione della parte pneumatica DESCRIZIONE Impostazioni di fabbrica indirizzo Alimentazione Protezione Assorbimento di corrente max tutte le valvole ON Indirizzameto N max dell indirizzo impostabile Diagnostica di difetto periferico Difetti segnalati Stato del modulo in caso di difetto 3 24VDC 10 polarit 500 mA MODULO PROFIBUS DP PER VALVOLE HDM Slave protetto da sovraccarico e da inversione di Uscite protette da sovraccarichi e cortocircuiti Tramite selettori rotativi 99 Segnalazione locale tramite LED e segnalazione al Master Cortocircuito o sovraccarico dell uscita Mancanza delll alimentazione ausiliaria Comunicazione Profibus attiva periferico Il bit Difetto Periferico attivo e accessibile alla stazione master Valore del bit di dato 0 non attivo 1 attivo Stato delle uscite in assenza di Inattive comunicazione Address mapping depends on Master configuration 5 TECHNICAL DATA For general features refer to the pneumatics section DESCRIPTION Factory setting address Power supply Protection Max input current all valves ON Addressing Max settable address numbers