Home
User Manual - Doughty Engineering
Contents
1. V PRODUCT SERVICE GMBH Department TFDEMA MAS Date 03 03 99 PRODUCT SERVICE T V PRODUCT SERVICE GMBH Zertifizierstelle gt Ridlerstrasse 31 D 80339 M nchen www doughty engineering co uk Doughty Engineering Ltd Crow Arch Lane Ringwood Hampshire BH24 1NZ Tel 44 0 1425 478961 Fax 44 0 1425 474481 email sales doughty engineering co uk Web www doughty engineering co uk Note Whilst every effort has been made to ensure that the information contained within this manual is correct Doughty Engineering does not accept any liability for errors or omissions Specifications and technical data are intended for guidance purposes only and may vary www doughty engineering co uk
2. Boucury User Manual www doughty engineering co uk T57000 10 Doughty Half Coupler Version 12 10 www doughty engineering co uk NB The TUV Certificate endorses T57000 Polished coupler only Parts amp Features Top Eyebolt Assembly Roll Pin Roll Pin Base Year of Manufacturer Month of Manufacturer i e 09 2009 Jan 10 22010 B Feb 1122011 C March Safe Working Load www doughty engineering co uk 1 Never exceed the Safe Working Load SWL shown on the clamp 2 Only use the clamp within the designed tube parameters 48 51mm 3 All clamps should be visually inspected before use In the event of any damage the clamp should be taken out of service and returned to an Approved Doughty Service Agent for inspection see our dealer locator on our web site for a comprehensive list of Authorised Service Agents 4 When used in conjunction with other accessories care must be taken to ensure that the minimum SWL of any component is not exceeded 5 Doughty Engineering Ltd does not recommend using any clamps which do not fully used in a vertical orientation only RECOMMENDED SWL 22 Ib ft THE FOLLOWING APPLICATIONS WILL RESULT IN THE RECOMMENDED SWL BEING PROOF LOADING ON INSTALLATIONS IS RECOMMENDED REDUCED SWL encompass the tube for overhanging All open clamps including hookclamps should be 0 Max Torque 30 N m REDUCED DEPENDANT ON THE TUBE SURFACE FINISH
3. amp TORQUE SETTINGS APPLIED www doughty engineering co uk Data Sheet STRICTLY FOR REFERENCE PURPOSES ONLY THIRD ANGLE PROJECTION MIN TUBE SIZE 48MM MAX TUBE SIZE 51MM DATA SHEET DOUGHTY ENGINEERING LTD TITLE PART NOS MATERIAL NSTI 107 REF MIN TUBE SIZES 48MM MAX TUBE SIZE 51MM www doughty engineering co uk DOUGHTY PRODUCTS MUST ONLY BE SERVICED REPAIRED BY AN AUTHORISED SERVICE AGENT SPARE PARTS ARE ONLY AVAILABLE TO THESE AGENTS 4 0 375 X 1 75 STAINLESS STEEL ROLL PIN 2 DRAWN MC 1 T57000 DOUGHTY CLAMP 211210 1 2 3 www doughty engineering co uk Declaration of Conformity Doughty Engineering Limited CROW ARCH LANE RINGWOOD HANTS BH24 1NZ ENGLAND Telephone 44 0 1425 478961 Fax 44 0 1425 474481 www doughty engineering co uk email sales doughty engineering co uk EC DECLARATION OF CONFORMITY Doughty Engineering Limited hereby certify that the equipment stated below has been designed to comply with all relevant sections of the specifications referenced below and complies with all the applicable Essential Requirements of the EC Directives and amendments and the National Laws and Regulations adopting these Directives Description Doughty Half Coupler Model s Part No T57000 T57010 SWL 750Kg Factor 5 1 are in conformity with the provision of the following EC Directives MACHIN
4. ERY DIRECTIVE 98 37 EC Harmonised Standards applied EN 292 1 2 1991 BS EN ISO 9001 1994 Safety Tested DIN 31000 03 79 Safety Tested DIN EN 74 12 88 National Technical Standards amp Specifications applied BS 7905 1 2001 d uin Signed fe 222 Date 23 04 08 Name Nigel Curtis Position Technical Director Being the responsible person appointed by the manufacturer DEQ 083 Rev 4 Company Registration No London 972614 Registered Office Crow Arch Lane Ringwood Hants BH24 1NZ LAE PUB ASA Directors M B Lister J C G Chiverton N D Curtis S C Wright www doughty engineering co uk TUV Certificate Certificate No B 99 03 20319 006 Doughty Engineering Ltd Crow Arch Lane Ringwood Hampshire BH24 1NZ Great Britain with production facilities 20319 is authorized to label the following products with the certification mark E as shown in the certification mark list See also notes overleaf Product Rohrkupplungen f r mechanische Verbindung Half Couplers Model T57000 Standard Parameters Max load capacity 750kg Tube diameter 48 50mm Width 50mm Thickness of the bottom 19mm Material 6082 ALSi1MgMn Weight 641g The product meets the relevant safety requirements and was tested according to Report No 01301602801 E 97 02 20319 001 DIN 31000 03 79 DIN EN 74 12 88 in Anlehnung Released with the above certificate number by the certification body of T
Download Pdf Manuals
Related Search
Related Contents
FCHB NOTICE D`UTILISATION ET D`ENTRETIEN 2. Dr.Web LiveCD Graphic Shell Samsung SCX-3400F Užívateľská príručka CF no /DCTA/96 Rio de Janeiro, de maio de 1996. Pelco IS150 User's Manual Cámara Deportiva Wöhrle Benutzerhandbuch für CS121 Serie + Dataflex 53.893 mounting kit IBM LIVEmail - Guia do Usuário Copyright © All rights reserved.
Failed to retrieve file