Home
        UB-R02 User's Manual
         Contents
1.       UB RO2 User   s Manual    Copyright    SEIKO EPSON CORPORATION 2004  Printed in Japan 2004 01    404861602       Introduction    The UB RO2 is an interface board on which is installed an IEEE 802 11b Radio  Frequency  RF  module for EPSON   TM printers     This manual provides instructions  including a simple setup for operators of  POS systems in which the UB R02 is installed so that the operators can use the  UB RO2 safely and correctly     Key to Symbol    The symbol in this manual is identified by its level of importance  as defined  below  Read the following carefully before handling the product     Q Note     Notes have important information and useful tips on the operation of your equipment     Features and Functions  d   64 128 bit WEP     1 Protocols  TCP  UDP  ICMP  IP  LP LPR  for APD   TCP socket port  for  OPOS      1 Transfer rate  up to 11 Mbps  depending on operating environment    m OPOS  APD support    Part Names  The following view shows the part names of the UB R02        Push button Drawer kick out Power supply  connector connector    Note  This photograph shows the TM T88lll printer with the UB RO2 installed        DIP Switches    When using this interface board  the interface of the TM printer must be  selected as    parallel    with the appropriate settings  Set the reset signal for pin  31 to    enable     if you are using a TM printer that has this setting  Refer to the  manual for each TM printer for details     How to Set Up the UB R02  Prepa
2.     www epson pos com   Select the product name from the    Select any product    pull down menu     EMC Standards Applied    Product Name  UB R02  Model Name  M195A    The following standards are applied only to the interface boards that are so labeled   EMC is tested using the EPSON  power supplies and TM series printers      Europe  CE marking   North America  EMI  FCC ICES 003 Class A   Oceania  EMC  AS NZS 3548  CISPR22  Class B    WARNING    You are cautioned that changes or modifications not expressly approved by Seiko Epson Corporation could void your  authority to operate the equipment     CE Marking  The printer conforms to the following Directives and Norms   Directive 89 336  EEC EN 55022 Class B   EN 55024    TEC 61000 4 2  TEC 61000 4 3  TEC 61000 4 4  TEC 61000 4 5  TEC 61000 4 6  TEC 61000 4 11  The printers in which this board is installed do not conform to the following     Directive 90 384 EEC EN 45501  FCC Compliance Statement For American Users    This equipment has been tested and found to comply with the limits for a Class A digital device  pursuant to Part 15  of the FCC Rules  These limits are she atta to provide reasonable protection against harmful interference when the  equipment is operated in a commercial environment    This equipment generates  uses  and can radiate radio frequency energy and  if not installed and used in accordance  with the instruction manual  may cause harmful interference to radio communications    Operation of this equipmen
3. onnect the equipment into an outlet on a circuit different from that to which the receiver is connected     Consult the dealer or an experienced radio TV technician for help     For body worn operation  this CF114100 has been tested and meets the FCC RF exposure guidelines when used with  the Universal Scientific Industrial Co   Ltd  accessories supplied or designated for this product  Use of other  accessories may not ensure compliance with FCC RF exposure guidelines     CANADA    This device conforms to IC  Low Power License Exempt Radio Communication Devices  RSS 210    The information such as Certification No   Model Name  and Manufacturer Name are described on the surface of the  module     EUROPE    Hereby  Universal Scientific Industrial Co   Ltd   declares that this CF114100 is in compliance with the essential  requirements and other relevant provisions of Directive 1999 5 EC     The UB R02 can be used only in the countries listed below     Austria  Belgium  Germany  Luxembourg  Netherlands  Switzerland  France  Italy  Greece   Spain  Portugal  Denmark  Finland  Ireland  Sweden  UK  USA  Canada  Australia  and  New Zealand     All rights reserved  No part of this publication may be reproduced  stored in a retrieval system  or transmitted in any form or  by any means  electronic  mechanical  photocopying  recording  or otherwise  without the prior written permission of Seiko  Epson Corporation  No patent liability is assumed with respect to the use of the information c
4. ontained herein  While every  precaution has been taken in the preparation of this book  Seiko Epson Corporation assumes no responsibility for errors or  omissions  Neither is any liability assumed for damages resulting from the use of the information contained herein    Neither Seiko Epson Corporation nor its affiliates shall be liable to the purchaser of this product or third parties for damages   losses  costs  or expenses incurred by purchaser or third parties as a result of  accident  misuse  or abuse of this product or  unauthorized modifications  repairs  or alterations to this product  or  excluding the U S   failure to strictly comply with Seiko  Epson Corporation s operating and maintenance instructions    Seiko Epson Corporation shall not be liable against any damages or problems arising from the use of any options or any  consumable products other than those designated as Original EPSON Products or EPSON Approved Products by Seiko Epson  Corporation     EPSON is a registered trademark of Seiko Epson Corporation     Windows is a registered trademark of Microsoft Corporation  USA     General Notice  Other product and company names used herein are for identification purposes only and may be trademarks of  their respective companies     Notice  The contents of this manual are subject to change without notice  Please contact us for the latest information     Printed on Recycled Paper    
5. ration  Printing a Status Sheet    Power on the printer  Wait for a few seconds  Then  hold down the push  button on the interface card for more than 3 seconds  The printer prints the  parameters for the UB R02  You can check all setting values necessary  SSID   Network mode  IP address  Subnet mask  Gateway address  for the network  connection     Connection    Set the setting of the host PC and AP to match the network setting that you  have confirmed with the status sheet     You can check whether the connection to the printer has been correctly done  by inputting the ping command through the command prompt     Example  Ping 192 168 192 168    Q Note     Although the example shows the address 192 168 192 168  use whatever IP address is  reported on the status sheet     Because the default IP addresses for all the wireless printers are the same  you should  power on and configure only one printer at a time     Resetting the UB R02 to Factory Defaults    Hold down the push button on the interface card while turning on printer  power and continue to hold it down for 5 seconds  This causes all internal  settings to return to their factory defaults     Setup    The TMNetWinConfig  version 2 0 or later  and the UB RO2 Technical  Reference Guide are necessary for setup  Obtain them from the appropriate  web site below     For customers from North America  go to the following web site   http   pos epson com     For customers from other countries  go to the following web site   http
6. t in a residential area is likely to cause harmful interference  in which case the user will be  required to correct the interference at his own expense     FOR CANADIAN USERS    This Class A digital apparatus complies with Canadian ICES 003   Cet appareil num  rique de la classe A est conforme a la norme NMB 003 du Canada     RF Module    This equipment contains the following wireless module   Manufacturer  Universal Scientific Industrial Co   Ltd   Model Name  CF114100   Product Name  USI WLAN CompactFlash Card Type I       USA   This device conforms to Part 15 of the FCC rules    This device has been tested and found to comply with the limits for a Class B digital device  pursuant to Part 15 of the  FCC Rules  These limits are designed to provide reasonable protection against armful interference in a residential  installation  This equipment generates  uses  and can radiate radio frequency energy and  if not installed and used in  accordance with the instruction manual  may cause harmful interference to radio communications  However  there is  no guarantee that interference will not occur in a particular installation  If this equipment does cause harmful  interference to radio or television reception  which can be determined by turning the equipment off and on  the user is  encouraged to try to correct the interference by one or more of the following measures     Reorient or relocate the receiving antenna     Increase the separation between the equipment and receiver     C
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
(第9版)(PDF)  iVMS-2000 V2.0.0 User Manual  Hydro Multi-S  Ressources n° 3 - mai 2013  Manuel d`utilisation Modèle SDL500  取扱説明書    Fresh Breeze  Betriebsanleitung Parflare ECO    Copyright © All rights reserved. 
   Failed to retrieve file