YA Gold Series User's Manual
Contents
1. A OHAUS YA Gold Series User s Manual Thank you for purchasing our scale Normal care and proper treatment will provide for years of reliable service Please read all operating instructions carefully before use It may be necessary to calibrate the scale before the first use PROPER OPERATION AND ENVIRONMENT e Avoid any exposure to extreme heat or cold your scale works better when operated at normal room temperature It is recommended to allow the scale to acclimate to normal room temperature for at least one hour before use e Allow your scale sufficient time to warm up Usually 30 60 seconds to give the internal components a chance to stabilize before calibration e Keep your scale in a clean environment Dust dirt moisture vibration air currents and a close distance to other electronic equipment can cause an adverse effect on the reliability and accuracy of your scale e Handle your scale with care Gently apply all items or samples to be weighed onto the weighing surface Although this scale is designed to be quite durable try to avoid rough treatment as this may permanently damage the intemal components e Avoid shaking dropping or otherwise shocking the scale This IS a precision instrument and must be handled with extreme care e Only operate the scale on a stable vibration free surface SPECIFICATIONS Models YA102 YA302 YA501 Capacity 100gx0 01g 300gx0 05g 5009x0 19 Units g oz ct gn dwt Calibration
2. External Calibration Tare Range Full Capacity Auto off default 10 30 seconds Operation Temperature 10 30 C Display LCD Power 2 x AAA Batteries OPERATION e Place the scale on a horizontal flat surface then press the ON OFF button e Wait untl 0 00 Is displayed e Put thee object or sample on the weighing platform e Using the MODE key to switch between weight units TARE WEIGHING Tum on the scale as described in OPERATION e Place the tare item weighing container on the weighing platform e Press TARE and wait until 0 00 is displayed e Add the sample into or on the weighing container CALIBRATION e Turn on the scale as described in Operation e Wait untl 0 00 is displayed e Press and hold the MODE key until the display reads CAL e Pres the MODE key again and wait for the LCD display to flash e Place the weight according to the LCD disply on the center of the platform and press the MODE key again e Wait until the display displays PASS and then remove the weight e Press the ON OFF button to turn off the scale PLEASE CHECK FOR THE AVAILABILITY OF WEIGHTS FROM THE COMPANY YOU BOUGHT THE SCALE FROM TROUBLESHOOTING The primary reason for inaccuracy or malfunction of the scale is due to low batteries or incorrect installation of batteries incorrect or infrequent calibration overloading the scale or operating the scale on an unstable Surface Please keep in mind
3. t conforms to the EMC directive 89 336 EEC and the Low Voltage Directive 73 23 EEC The complete declaration of Conformity is available from Ohaus Corporation AS NZS4251 1 Emission AS NZS4252 1 Immunity Disposal In conformance with the European Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE this device may not be disposed of in domestic waste This also applies to countries outside the EU per their specific requirements Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment If you have any questions please contact the responsible authority or the distributor from which you purchased this device Should this device be passed on to other parties for private or professional use the content of this regulation must also be related Thank you for your contribution to environmental protection Ohaus Corporation 19A Chapin Road P O Box 2033 Pine Brook NJ 07058 USA Tel 973 377 9000 Fax 973 593 0359 www ohaus com With offices worldwide 8025 1913 mimon Ohaus Corporation 2006 all nights reserved Printed in China
4. to maintain and operate your scale properly The scale is a precision instrument and must be handled with the utmost care and caution DISPLAY ERRORS lo 88888 or not display change the batteries OUT2 recalibrate the scale per the instructions above O Ld The scale is overloaded Remove the object from the weighing tray immediately EEEEE or LLLLL The internal components have been damaged i e twas shocked dropped or excessively overloaded Try to recalibrate the scale If the scale was not damaged too much recalibration may fix the problem UNST Use the scale in a more stable i e flat position NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme a la norme NMB 003 du Canada This produc
Download Pdf Manuals
Related Search
Related Contents
Samsung 24" TV (LED) monitor 顯示器、電視兼用 TD390 User Manual File - Servicing all your beverage needs since 1988 Produktübersicht in PDF Gembird VGA, 10 m User's guide for: MUZZLELOADING FIREARMS Guía del usuario CM3G-CM3GP-CM3GPP Media Giant Mobile Marketing Strategy Guide MANUAL DEL USUARIO - Icon Heath & Fitness Wilo-IF-Modul Modbus Wilo-IF Copyright © All rights reserved.
Failed to retrieve file