Operating Instructions Busch-Dimmer® Memory - Busch

image

Contents

1. 2 Intended use The device is to be used exclusively with the components that are supplied and licensed as described in chapter Setup and function 3 Environment Consider the protection of the environment Used electric and electronic devices must not be disposed of with domestic waste The device contains valuable raw materials which can be recycled Therefore dispose of the device at the appropriate collecting depot All packaging materials and devices bear the markings and test seals for proper disposal Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies The products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive 2002 96 EC WEEE and 2002 95 EC RoHS EU REACH ordinance and law for the implementation of the ordinance EC No 1907 2006 Operating Instructions 1473 1 7934 3 Operating Instructions I LIIC A L T KFA rYA bUuUSCN VIMMe 4 Operation Dimmer operation flush mounted construction type Operation with clip on control element 6543 directly on the dimmer Alternatively operation is also possible via conventional push buttons 2020 US and 2021 6 UK e Briefly touch the operating surface to switch the lighting on or off e Pressing the operating surface for a longer period will change the brightness value of
2. _ RL 6 1 Features of function and equipment e Light storage e The set brightness value is stored even after switching off the lighting system e Phase angle e Parallel operation of several transformers and or incandescent lamps possible e Without control element 6 2 Possible combinations 6560 101 Operating Instructions 1473 1 7934 5 Operating Instructions Busch Dimmer Reduction of the connection load derating T Reduction of the connection load derating The dimmer heats up during operation because part of the connected load is lost and converted into heat The specified rated power is designed for dimmer installation in a solid masonry wall When installing the dimmer in a wall made of gas concrete wood or plasterboard the maximum connection load must be reduced by 20 The connected load must always be reduced when several dimmers are installed one below the other or when other heat sources cause additional heating In intensely heated up rooms the maximum connected load must be reduced according to the diagram Use the following formula for the calculation of the nominal power Nominal power transformer losses lamp power For conventional transformers 20 of nominal power of transformer 0 10 20 30 40 50 60 70 80 C Fig 1 Derating Unit Meaning Nominal power C Ambient temperature Operating Instructions 1473 1 7934 6 G SEE ch Dimme 8 Inst
3. the lighting This process stops when the minimum and maximum brightness value has been reached When switching the lighting off this value is stored until the next switch on Dimmer operation MDRC construction type Operation is only possible via conventional pus buttons 2020 US and 2021 6 UK 5 Technical data eneral Nominal voltage 230 V AC 10 50 60 Hz flush mounted insert 230 V AC 10 50 Hz rail mounted device MDRC Nominal power 20 500 W VA depending on the ambient temperature a power loss of 20 in case of conventional transformers needs to be considered Minimum load 20 VA Semiconductor switching contact Break contact 0 mm Overload protection Temperature limiter Module width 3 MW 1 MW 18 mm applies only to Modular DIN Rail Component MDRC Short circuit protection T 3 15 H Radio interference suppression According to EN 55015 Total ambient temperature range 0 70 C Connected load Ambient temperature range 0 35 C connected load 100 Ambient temperature range 35 70 C reduced connected load Derating Operating Instructions 1473 1 7934 d Operating Instructions Busch Dimmer Setup and function 6 Setup and function The device is intended for the activation of the following types of loads V San 230 V incandescent lamps Q 230 V 230 V halogen lamps IL Low voltage halogen lamps with conventional transformers
4. 1473 1 7934 Rev 01 17 12 2012 Operating Instructions Busch Dimmer Memory touch dimmer 6560 U 101 p Busch Memory Tast PN 6 5 6 0 1 O 1 Z Dimmer 6560U 101 I 230V 50 60Hz 25 500W VA 5 amp 1 ie ve yo PE BUSCH MEMORY TASTDIMMER 6560 Freischalten durch Entnahme der Sicherung Sicherung unter dieser Abdeckung BUSCH JAEGER Vv Operating Instructions Busch Dimmer 1 SO De an ae Oe SE oe E EASE Soe ne Oa ee ne ee eee rn a ee eee ere ane mere 3 2 DGT U1 gt ieee ete te eer en ne ce cee Ba BB OO BA Oe Nee Sa al Se Ban nn a ae a ee 3 3 ENVION aT 3 4 CTT a a e en ae ae eee 4 5 EE ENAT ELES e 1i E E E N O S EEE AE E PE E AE EE ETEA A EEN EEE OE T IR EE E EEE TAE E EN A AR 4 6 Setup and UNCION TTT 5 6 1 Features of function and equipment nui sees eee ee Aen nn 5 6 2 FP OSSIDIC COMIN AON S 22er ee ee ee 5 T Reduction of the connection load derange sees eee eee 6 8 Installationcand electrical CONNECUON TTT 7 8 1 Requirements Tor the electrician an ee T 8 2 MOUNING TTT 8 8 3 Electrical Connec Oiane a a a a a N 9 Operating Instructions 1473 1 7934 2 Operating Instructions R IISC a TY mmer 7 DUSLI UITTNEI 1 Safety Warning Electric voltage Risk of death and fire due to electrical voltage of 230 V Work on the 230V supply system may only be performed by authorised electricians Disconnect the mains power supply prior to installation and or disassembly
5. allation and electrical connection Warning Electric voltage Risk of death due to electrical voltage of 230 V during short circuit in the low voltage line Low voltage and 230 V lines must not be installed together in a flush mounted socket 8 1 Requirements for the electrician Warning Electric voltage Install the device only if you have the necessary electrical engineering knowledge and experience e Incorrect installation endangers your life and that of the user of the electrical system e Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows e Apply the five safety rules DIN VDE 0105 EN 50110 1 2 3 4 5 Disconnect from power Secure against being re connected Ensure there is no voltage Connect to earth and short circuit Cover or barricade adjacent live parts e Use suitable personal protective clothing e Use only suitable tools and measuring devices e Check the supply network type TN system IT system TT system to secure the following power supply conditions classic connection to ground protective earthing necessary additional measures etc Operating Instructions 1473 1 7934 Operating Instructions Busch Dimmer Installation and electrica 8 2 Mounting Warning Electric voltage Risk of death and fire due to electrical voltage of 230 V Work o
6. ced transmitted or reused by third parties without prior written consent by ABB Copyright 2012 Busch Jaeger Elektro GmbH All rights reserved BUSCH JAEGER l 1473 1 7934 Rev 01 17 12 2012
7. n the 230V supply system may only be performed by authorised electricians Disconnect the mains power supply prior to installation and or disassembly The flush mounted insert must only be installed in flush mounted wall boxes according to DIN 49073 1 Part 1 or suitable surface mounted housings The MDRC must only be installed on mounting rails according to DIN EN 500022 The MDRC is latched onto the mounting rail Caution Risk of damaging the device due to overheating When using transformers ensure that each transformer is fused individually on the primary side or with a thermal fuse according to the manufacturer s specifications Use exclusively wound safety isolating transformers according to DIN VDE 61558 Caution Risk of damaging the device due to excessive voltages Extended operation of an unloaded transformer e g with a faulty bulb connected to a dimmer may destroy both the transformer and the dimmer This is caused by a possible voltage rise which may occur between an unloaded transformer and the dimmer Connect at least two incandescent lamps per transformer or at least two transformers per dimmer Replace defective incandescent lamps immediately A A O Note on operating transformers with dimmers To achieve the same linear rise in the brightness level of halogen lamps over the entire adjusting range from bright to dark transformers with the same secondary voltage and the same power sho
8. uld be used When installing please bear in mind that transformers depending on their quality and version may generate humming noise when used with dimmers Use an inrush current limiter if excessive inrush currents occur Operating Instructions 1473 1 7934 8 Operating Instructions Busch Dimmer Installation and electrical connection 8 3 Electrical connection O Note on adapting the connected load to the ambient temperature In intensely heated rooms the maximum connected load must be reduced according to the following derating diagram 16A Le N X A l O 00 Fig 2 Circuit diagram Operating Instructions 1473 1 7934 9 Operating Instructions Busch Dimmer A member of the ABB Group Busch Jaeger Elektro GmbH PO box 58505 L denscheid Freisenbergstra e 2 58513 L denscheid Germany www BUSCH JAEGER com info bje de abb com Central sales service Phone 49 0 2351 956 1600 Fax 49 0 2351 956 1700 Notice We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or extracts thereof must not be reprodu