Home
Operating Instructions Safety instructions -
Contents
1. Operating Instructions KNX IP router 2167 00 GIRA KNX IP interface 2168 00 Gira Giersiepen GmbH amp Co KG Electrical Installation Systems P O Box 1220 42461 Radevormwald Phone 49 0 2195 602 O Fax 49 0 2195 602 339 www gira de info gira de Safety instructions Installation and mounting of electrical devices may only be carried out by quali fied electricians Failure to observe the instructions can result in damage to the device fire or other dangers These instructions are part of the product and must stay with the customer Device design KNX EIB 2168 00 100 IP Schnittstel m instabus NE E13 KNX EIB GIRA 2167 00 100 IP Router instabus GRR E13 Bereich IP router 1 Programming button 2 KNX connection 3 External power supply connection 4 Programming LED red interface router yellow data logger clock 5 Operation indication green on ready for operation flashes diagnosis code 6 Data reception on KNX line yellow N Network connection 8 microSD card reader Function System Information This device is a product of the KNX system and complies with the KNX guidelines Detailed specialist knowledge gained in KNX training Courses is assumed for understand Ing Functionality of the device is dependent upon software Detail
2. ed information about software versions specific ranges of functions and the software itself can be found in the manufacturer s product database Planning installation and start up of the device is with the aid of KNX certified soft ware The up to date product database and technical descriptions are available on our internet page Proper use IP interface Coupling of a PC for the addressing program ming and diagnosis of KNX EIB components IP router Connection of KNX EIB lines with aid of data networks and use of the internet protocol IP Coupling of a KNX EIB system together with the Gira HomeServer FacilityServer Product features IP interface Supply via external DC 24 V IP router Filtering and forwarding of telegrams Use as line area coupler Use as KNX clock Recording of KNX telegrams on microSD card Supply via external DC 24 V Information for electricians Installation and electrical connection A DANGER Electric shock if live parts are touched in the installation surroundings Electric shock may lead to death Isolate before working on the device Cover up live parts in the vicinity Mounting the device Observe the temperature range Ensure suffi cient cooling Snap the device onto a top hat rail accord ing to DIN EN 60715 See the illustration for installation position Connect the external power supply to the connection terminal 3 We recommend use the wh
3. ite yellow connection terminal Connect the KNX line with the red black bus terminal 2 Attach the cover cap over the KNX external power supply connection Connect the network connection to the RJ pin jack with the RJ45 plug 7 Insert the microSD card in the card reader 8 IP router Attach the cover cap A cover cap must be attached to protect the bus connection from dangerous voltages in the connection area Guide the bus line to the rear Attach the cover cap over the bus terminal until it engages Remove the cover cap Press the cover cap on the sides and re move Start up Load the physical address and application software address Data interface Data logger clock Start up software from ETS3 0f Area coupler IP router IP interface Briefly press the programming button 1 lt 4 seconds Programming LED 4 lights up red Assign the physical address Programming LED 4 goes out Label the device with the physical address Load the application software filter tables parameters etc IP router as data logger clock Press and hold the programming button 1 gt 4 seconds Programming LED 4 lights up yellow Assign the physical address Programming LED 4 goes out Label the device with the physical address Load the application software and parame ters Appendix Technical data KNX medium Start up m
4. ode KNX supply KNX current consumption KNX connection External supply Voltage Power consumption Connection IP communication IP connection Supported protocols microSD card Ambient temperature Storage temperature Installation width Accessories Additional power supply Order No 1296 00 TP1 S mode ETS DC 21 30 V SELV typ 85 mA Bus connection terminal DC 24 30 V 2 W with DC 24 V Connection terminal Ethernet 10 100 Basel 10 100 Mbit s RJ45 pin jack ARP ICMP IGMPv3 DHCP AutolP UDP IP core routing tunneling device management max 32 GByte SDHC 0 C to 45 C 25 C to 70 C 36 mm 2 HP KNX EIB power supply 320 mA Order No 1086 00 Warranty The warranty is provided in accordance with statutory requirements via the specialist trade Please submit or send faulty devices postage paid together with an error description to your responsible salesperson specialist trade installation company electrical special ist trade They will forward the devices to the Gira Ser vice Center
Download Pdf Manuals
Related Search
Related Contents
User Manual Sanyo CAS-D6325 User's Manual Alpine SPS-110TW car speaker Indice caviglia-braccio e funzione misurazione simultanea su Kenwood UD-100 User's Manual Manuale d`installazione ST8100 Display System Bedienungsanleitung Oregon Scientific RM308P Rental power box FOG-900 Copyright © All rights reserved.
Failed to retrieve file