1.    Gruetzner  LUBRICUS m       User Guide    Lubricus Lubrication System    LUB D1 LUB De LUB DS LUB D4     24 VDC        version 04 2013    LUBRICUS    Content    General Information  Warning   scope of Supply  Overview   General safety details  Intended use   Extent of warranty  General safety information  Transport and storage    Function  Principle  Communication Interface  Connector PIN assignment    Installation instruction  Pulse signals details  Functional problems  error  message and problems  Service  replacement of cartridge    Technical Data  Recommended tube length    Mounting    Disposal    WwW WW O amp O    ARS    11  11    12    12    Gruetzner  GmbH     version 04 2013       Gruetzner  LUBRICUS m     General Information   Thank you very much deciding to use Lubricus Lubrication System  Make sure that you familiarize yourself with the safety  instructions of Lubricus Lubrication System and the accessories supplied with this unit  This manual contains important  safety information     The Lubricus Lubrication System is a very compact lubrication pump for oil and grease up to NLGI 2  The pump requires 24  VDC power supply  The lubricant reservoir  400 cm   is contained in cartridge  Supply pressure is up to 70 bar  1 000 psi    The Lubricus Lubrication System Type D is available with up to 4 outlets     Warning    Lubricus Lubrication System is designed for use in normal industrial environment indoor as well as outdoor but is not suitable  for mounting on moving
2.   IMPORTANT    Please pay attention  not only to the safety instructions under this main point  but also to those special security cautions that  are mentioned on the other pages     This symbol warns of electrical voltage        This symbol warns of electrical voltage        4 version 04 2013       Gunnell  LUBRICUS            ant This heading is used if inaccurate compliance or non compliance with the operating Instructions or  Attention    specified work procedures etc  may result in damage     Points out special information     Notes attached directly on the machine  must be strictly followed and maintained in completely readable  condition     Qualification and training of the personnel    The operation  maintenance  service and installation personnel must have appropriate qualifications for this  work  Responsibility and supervision of the personnel must be clearly defined by the end user   operator  If  the personnel do not have the necessary knowledge  they must be trained and instructed  The operator must  ensure that the personnel have completely understood the contents of the user information        Non observance of the safety information can be dangerous    Not observing the safety information can lead to danger for people  environment and machines   Not observing the safety information can mean the loss of any or all damage claims  In special cases  non   observance can  for example  lead to the following dangers        Failure of important plant functions    Fa
3.  Gruetzner  LUBRICUS m    Function Principle   When you activate Lubricus  Type D  the piston pump starts to work and pump the lubricant in small quantities to the outlets   The integrated microprocessor controls the function  Communication with the machine controller is necessary  Delivery rates  and time between the lubrication intervals can be individually set by pulse signals    The Lubricus Lubrication System uses a four pin socket to connect a M12X1 plug allowing communication with the machine  controller  An external 24 VDC power supply is used to switch ON and OFF  voltage of  20     up to  30 VDC  supplied to  PIN 1   When voltage is supplied the lubrication pump is in operating condition  If there are no errors  Pump OK  the input  voltage will be transferred to the output signal  PIN 4  indicating all is OK  Once the voltage supply to PIN 1 is stopped     switched OFF   the pump rests and saves the current operating conditions in memory  When the pump is turned back on the  saved operating conditions will be continued  PIN 4 relays the operating condition     Connector PIN assignment  connection to Lubicus  Type D    Connector PIN assignment M 12 x 1   PIN 1  input voltage  20   30 VDC  color brown   PIN 2  activation of the individual pump outlets  color white  PIN 3    Ground  GND   color blue   PIN 4  Output Signal  color black   Details     Peak current Imax  during pump operation  approx  350 mA   typically  lt  200 mA  Standby current  standby mode   lt  20 m
4.  equipment for example trucks  Only use original Lubricus cartridge and original spare parts  None  original spare parts can destroy the Lubricus Lubrication System     Scope of supply    Standard delivery includes     Lubricus Lubrication System    Tube connector attaches to the outlet  suitable for flexible tube 6 x 4        6mm outside and    4mm inside diameter      Operating Instructions    Overview    The setup of your   Lubricus Lubrication System is easy  This user manual will learn you the basic operation and  adjustments     Ventilation Lock    Pa Housing         lt  lt  Connection M12x1 external control    Important remark  unused outlets must remain open to avoid damage to the pump     3 version 04 2013    LUBRICUS    Gr vetzner n    General safety details  Everybody who is involved with the installation  start up  maintenance and operation of the Lubricus Lubrication System must  read these instructions carefully     Use in accordance with guide    Lubricus Lubrication System is only allowed for industrial use   Lubricus Lubrication System may only be put into service  if it is integrated or attached to another    Attention  machine and will be operated together with that machine   Lubricus Lubrication System may only be used according to the technical data  see chapter     technical data        Unauthorized structural changes at the Lubricus Lubrication System are not permitted  We do  not assume liability for damages of persons or machines which result from tha
5.  water Operation up to 1 m   Combination with   progressive systems possible    Recommened tube length  Keep in mind   For low temperature   For stiff grease  more than NLGI 2   For difficult applications with high backpressure    gt  Shorten your tube as much as possible    gt  Minimum inner diameter is 4mm Q    gt  Avoid reductions of the inner tube    70 oo  60 SS  low temperature  50 t stiff grease  40 a S S E   backpressure  n aT 10 bar    Pressure  bar        Length  m     Chart  Required pressure vs  tube length  tested with tubes 6 x 4 mm     11 version 04 2013       Gruetzner  LUBRICUS m    Mounting FlexxPump    2 srews    6mm  for example M6x40 are required for a safe installation of your FlexxPump  The optimum tightening torque  of the screw is 5 Nm  3 points at the back assure a safe support     a    A an nen DAT  a8 a ass    Auflagqeflachen  fasterinq support       Disposal    When disposing lubricant the waste disposal instructions of the lubricant manufacturer must  be observed     Disposal of Lubricus Lubrication System  observe the regional valid laws and regulations     The empty lubricant cartridges contain lubricant remains   Please dispose with other oil contaminated garbage     Gruetzner GmbH  Kohlenhofstr  60  D 90443 Nurnberg  www lubricus com  Tel    49 911 277 399 0  Fax   49 911 277 399 99    version 04 2013    
6. A    Output signal PIN 4  High   20   30 VDC    OK  Low   0 V   Error  empty signal  over current     The outlet signal  PIN4  can be charged with maximal  300mA Warning  the exit is not short circuit proof    A time delay fuse 1A is normally required        Output signal  in case of empty lubricant reservoir  PIN 4 generates an alternating high and low signal  switching with  0 5 Hz     Pump function control  after receiving a correct pulse signal at PIN 2  the pump starts to work  During the function of the  pump  about 7s  the output signal at PIN 4 is switching from High    20   30 VDC  to Low  0 V   By counting the signals of  the pump function control there is a possibility to estimate the delivered quantity of lubricant and the remaining quantity in the  lubricant reservoir  delivery rate per pulse signal  0 15 cm       7 version 04 2013       Gruetzner  LUBRICUS    mt       Installation and commissioning  Identification of the pump outlets       11 12 1 3 1 4    Pulse signal details  Indication in seconds  accuracy     10     delivery rate per pulse signal  0 15 cm   one outlet    time between two pulse signals  minimum 15 s      aclivale 1 1 3s         activate 1 1   1 2 3s 3s   outlets will be served alternatty High  and dispensed aqual quantities    High            from both outis  minimal 15 5   Low     aclivate 2 1  Highi   gt 55  ooo   Low     aclivale 2 1   2 2 6s 6s    High  minimal 185     outiats will ba sarad altarnatly  and dispensed equal quantitas  from 
7. both outlets     High         Low      activate 1 1   1 2  2 1 22   outiats will ba sarwed altarnatly  and dispensed aqual quantities Highi  from all cutlets       gt 55       Low    8 version 04 2013    4 Gruetzner e  LUBEBRICUS om    Functional problems   Error messages   faults  The dedicated error message is given to PIN 4   E1  Empty lubricant reservoir   PIN 4 generates an alternating high and low signal  switching with 0 5 Hz   Root cause  lubricant cartridge is empty     The pump will stop     Corrective action  replace cartridge   Pump will continue to run as per active program    E2  Back pressure too high   over current    Output Signal   Low   Root cause  Back pressure was measured 3 x too high  The lubrication point could be clogged  the tube length could  be too long or the grease is too stiff or has hardened  The pump will stop    Corrective action  Trace reason for high back pressure  gt  Obar and correct it   Switch unit    OFF    and    On    again  The error message will be reset to 0  The pump will start again as per  program in memory     System error  Switch unit    OFF    and    On    again  Memory will not be erased     Service  replacement of cartridge       Any further service is not necessary     1  Observe the safety instructions  Switch off the pump  Display     report    OFF       2  Take out ventilation locking  turn clock wise to OPEN        3  Press the housing  turn left and remove it    9 version 04 2013    t RICUS  4  Remove the empty cartr
8. idge   5  Remove protection from the new cartridge  6  Lubricate O Ring of the new cartridge slightly   7  Place the cartridge on the inlet       8  Place the pump upright on flat surface  Reinstall the housin    gently pressing while turning clockwise until hand tight     9  Install the ventilation lock and close it  turn counter clockwise to CLOSE     10  Pump will work again according to settings  error report will be deleted    Gr uetznera  GmbH                   version 04 2013       Gruetzner  LUBRICUS m       Technichal Data          196             Schlauchanschluk  Schlauch 6 4  connection   tube 6 4             abhangig von Schlauchanschlussteil  Stecker M12x1 according to tube fittings    connector WH2x4    Storage volume cartridge 400cm  or max  500ml oilreservoir   Lubricant oil or grease up to NLGI 2   Function   principle piston pump   Delivery rate per pulse signal 0 15 cm    Number of outlets up to 4   Connection high pressure tube 6 x 4  flexible tube    6mm outside and    4mm inside    Operating pressure max  70 bar   Operating temperature  20  C to  70  C   Operating voltage 24 VDC   Dimensions  max  Width x height x depth  112 x 196 x 94 mm  without tube fitting   Weight  without lubricant ca  1120g   Integrated Control micro processor controlled   Pressure monitoring integrated  electronic  monitoring backpressure    Level monitoring integrated  reedcontact   Connector M12 x 1  4 pole for connection with PLC   Protection class IP 65    suitable for under
9. ilure of prescribed methods of maintenance and preventive maintenance   Endangering people due to electrical  mechanical and chemical effects   Endangering the environment due to leaks of dangerous materials     Safety information for operators operating staff    e Hot or cold machine parts are hazardous and must be protected from touching  The protection on   moving or rotating parts  must not be removed     e  n case of leakages of dangerous media proper disposal not endangering environment and people must  be ensured     e Legal Regulation must be observed and complied   Eliminate any danger due to electrical power        Safety information for maintenance  inspection and assembly work    All maintenance  inspection and installation work may only be carried out by trained specialists who  have been informed appropriately by studying the user information closely    All work must only be carried out when machine is shut down and while wearing appropriate protective  clothing  Always comply with the procedures for shutting the machine down that are described in the  operating manual  All the safety and protective equipment must be replaced immediately after completing  work  Environmentally hazardous substances that endanger the environment must be disposed in  accordance with local regulations  Secure the system during maintenance and repair work  against  intentional or unintentional operation  Dispose of used lubricants in accordance with the safety data sheets of  the lub
10. ort and storage    Use suitable lifting gear for transport   Do not throw or expose the Lubricus Lubrication System to strong shock loads   Store the Lubricus Lubrication System in a cool and dry place to avoid corrosion of the system   s individual parts     Pay attention to the current safety  and accident prevention instructions during the transport  Wear suitable  protection equipment if necessary        Installation instruction    The following conditions have to be satisfied during the installation of this Lubricus Lubrication System  thus it  can be assembled  with other parts  to a complete machine without affecting the safety and health of  humans        The housing of Lubricus should not be exposed to direct sunlight and or radiant heat preventing the  formation of condensation     Electrical connection         Have the electric power supply connected only by a trained electrician      e Connection and wiring of the electric components should be done by an expert trained in this field   Te Check the voltage details with the existing power supply voltage        Maintenance  repair    Disconnect the voltage feed  before starting with maintenance or repair    Maintenance and repair work may only be done with the system shut down    Check the surface temperature of Lubricus Lubrication System  due to danger of burning by radiant heat   Always wear heat resistance gloves  Protect the system from activation during maintenance and repair work        6 version 04 2013      
11. ricant manufacturer        Alterations and manufacture of spare parts without authority    Rebuilding or altering the Lubricus Lubrication System is only allowed after consultation with the  manufacturer  Original spare parts and accessories authorized by the manufacturer are for safety  purposes  Using other parts results in loss of liability for claims resulting out of this  For components   retrofitted by the operator  the manufacturer does not assume guarantee nor claims for damages        5 version 04 2013    LUBRICUS    Gast  n    Prohibited methods of operation    Operational security of the Lubricus Lubrication System is only guaranteed if it is operated in accordance with the  operating instructions  The limit values stated in the technical data must not be exceeded under any circumstances     General risk reference    All components of the system are designed in accordance with the prevailing regulations of the construction  of technical machines  in regards to operational safety and accident prevention  Operation outside of these  constraints can lead to dangers for the user respectively third persons or other technical facilities  The  Lubricus Lubrication System therefore may fulfil only in technically fault free condition its intended use   This may only be carried out under compliance of the safety regulations and the attention of the operator s  manual    Therefore please regularly inspect the pump and its attachments for possible damage or leaks        Transp
12. t     Additional directives for use in accordance with the regulations     e Pay attention to all notes in the operator s manual   user guide   Carry out all maintenance work     e Follow all appropriate regulations for the work safety and accident prevention during life of the Lubricus Lubrication  System       Only qualified and authorized personnel can carry out required work on the Lubricus Lubrication System     Attention  Other uses or uses beyond those described above cannot be considered to be in accordance  with the regulations     Extent of warranty    Warranties concerning operating safety  reliability and capacity  are only granted under the following conditions   Assembly  installation  maintenance and repair are only carried out through trained specialist  Hazardous hot or cold  machine parts must be shielded to prevent touching     The Lubricus Lubrication System must be used according to the instructions in the technical operating manual   The rated technical data must not be exceeded in any case     Retrofitting and repair work on the Lubricus Lubrication System may only be done by the manufacturer     General safety information    Basic information  which must be followed during service  operation and maintenance  are listed as follows   It is absolutely essential to read the operator s manual   user guide by respective technical staff   technical operator before  installation and start up  In addition to this  it must be permanently available at the site   
    
Download Pdf Manuals
 
 
    