Home

Operating Instructions System Manual Video Control Device

image

Contents

1. Yes Yes o o WS 4 Video WS 3 Video 2 2 tise vy Resistor Resistor ws 4 Yes Yes WS 2 Video WS 2 Video 2 noe 2 2 of ws2 o WS 1 vv Outdoor station 2 VV Video distributor Control unit video 33 2 Rule Activate the terminating resistance of the last home station for looping through Resistor Yes WS 3 Video i Resistor No WS 2 Video mei o Resistor FEN no oll sese flo S0000 WS 1 Video Be 2 Outdoor station 2 Control unit video Home stations without the video function can simply be inte grated into the line and do not affect the setting of the last home station Resistor Yes WS 3 Video WS 2 Audio o o Resistor Sees No ol 22225 o WS 1 Video SAn WS 3 of ws2 fo WSs 1 2 Outdoor station
2. Resistor Yes WS 3 Video oO O ooooo 2 ET Resistor o S Yes z 2 WS 2 Video O O oo00o0 oo00o0 o oo000 o 0000 BORED ses 00000 2 2 6 A WS 3 ET o WS 2 o Resistor sat Yes a WS 1 Video 2 Outdoor station 2 so000 ETET 2 2 LN nam ET ET Floor call button WS Home station VV Video distributor Control unit video For the branching solution the terminating resistances of the home stations in the TFT display must be set to Yes see also Page 33 Loop through solution Resistor Yes WS 3 Video O 2 ET Resistor ie o No WS 2 Video 2 Oo oO o0o000 3588 90008 ee eee fe o0000 oo o o o0o000 s0000 o0000 2 OH WS 3 ET o WS 2 o Resistor WS No WS 1 Video Outdoor station Q O 2 2 00000 09000 2 OH 2 ET ET Floor call button WS Home station Control unit video A video distributor is not required
3. Housing bottom section colour camera Cable inlet Connection terminals Sealing ring Call button cover plates Housing top section Speech cover plate 3 gang call button OMAN OARWDN Structure of a home station with TFT display The basic structure of a home station with video function is pre sented in the example of the Comfort home station with receiver and TFT display 4 5 6 7 3 Receiver insert Empty insert Audio connection cable 6 pole Video connection cable 2 pole Door communication bus coupler Display insert Cover frame not included in scope of supply TFT display top unit 9 Operating buttons 10 Receiver 11 Receiver mount 12 Receiver mount with cable branch 13 Receiver cable AN onRWDN Door communication bus coupler Video System BUS AL Q System Tp zv ET The flush mounted versions of the door and home stations are connected to the 2 wire bus via door communication bus cou plers i Bus coupler jumpers he accompanying wire jumpers must be attached between BUS and ZV at the bus coupler in order for the colour camera TFT display to operate Therefore the call button illumination at the door stations can not be switched off The bus coupler has the following connections
4. BUS The devices are connected to the 2 wire bus via the BUS termi nals Polarity need not be taken into account during connection as the polarity of the door communication bus is neutral Floor call button ET With home stations any push button NO contact can be con nected to the ET terminals as the floor call button With the door stations for example a mechanical bell button NO contact can be connected This then acts like a call button from the Gira door communication system during start up and later operation The maximum cable length between the mechanical button and the door communication bus coupler is 20 m Additional supply ZV The ZV terminals have two functions 1 Power supply of call button illumination at the door stations The call buttons are constantly illuminated at the door sta tions with colour camera 2 Additional power supply for bus devices which can no longer be powered via the 2 wire bus This could be a third camera for example If an additional supply is connected remove the jumpers If an external supply is connected to the ZV terminals the jump ers between ZV and BUS must be removed at the respective bus coupler The following connectors are also available System The door communication inserts are connected to each other with the 6 pole audio connection cable via these connectors Video The door communication bus coupler is connected to the flush mounted inserts of the
5. 1 Press the System prog button on the control device for v 3 seconds to start programming mode see Page 18 Press the call button on home station 1 for 3 seconds until you hear a short acknowledgement tone You will hear a long acknowledgement tone i Releasing the button after 3 seconds If the button press is not ended after the first acknowledgement tone all assignments of the respective door home station will be deleted after an additional 3 seconds Press the G button on home station 2 for 3 seconds until you hear a short acknowledgement tone A long acknowledgement tone indicates successful assign ment Three short acknowledgement tones indicate faulty assign ment The memory of the home station may already be occu pied A maximum of 10 call buttons can be assigned to a home station a maximum of 15 call buttons to a surface mounted hand free feature home station 4 Press the Systemprogr button on the control device to exit the programming mode Carry out a function test 29 Deleting all assignments to a home station A home station which as already been assigned is deleted as fol lows hy 7 1 Press the System prog button on the control device for 3 s FOS N systemprogr PEN 3 seconds to start programming mode see Page 18 2 Press the 8 button on the home station for which the IL assignment is to be deleted for 6 seconds You will hear a brief acknowledgement
6. after a power failure In this case the automatic door opener is deactivated for secu rity reasons and must be reactivated if necessary 25 Assigning home station via floor call button If you cannot access the home during start up you can also assign the home station via a connected floor call button 3 s WA Sener 1 Press the System prog button on the control device for ae b 3 seconds to start programming mode see Page 18 3 sfv 2 Press the call button of the home station to be assigned at M Meier Q the door station for 3 seconds until you hear a short acknowledgement tone m a vy You will hear a long acknowledgement tone ae 3 Go to the floor call button of the home station to be assigned r Press the floor call button for 3 seconds until you hear a short acknowledgement tone A vy Along acknowledgement tone indicates successful assign gt ment Only possible with directly connected home station With several parallel home stations only the home station con nected directly to the floor call button can be taught in via the floor call button 1x06 4 Press the Systemprogr button on the control device to a bees exit the programming mode 4 26 Assigning several home stations to a call button fi 3s o Systemprogr as 1 3s 3s 3 Systemprogr If several home stations are to be called
7. with the planning software at www gira de A call tone differentiation is made between the following calls at the home stations e door call initiated by call button e floor call initiated by floor call button e internal call initiated by call button for home stations Cabling and cable arrangement Cables with a wire diameter of 0 6 or 0 8 mm can be used as bus lines The following cable types are suitable for use as bus lines e J Y ST Y communication line e YR insulated bell wiring e A 2Y L 2Y communication cable i Cabling for new installation We recommend communication line J Y ST Y for new instal lations of the Gira door communication system Cable lengths in video systems The maximum cable length between the colour camera and TFT display is 100 m Cable lengths in audio systems The maximum total cable length distributed among several wir ing sections is 700 m A maximum of 30 devices may be connected to each wiring sec tion The maximum cable lengths of the individual sections from the control device to the last device are dependent on the cable diameter used The guidelines for audio components are e 0 6 mm diameter 170 m e 0 8 mm diameter 300 m Installation scenario topologies Solution branching
8. The yellow LED next to the programming button flashes flash frequency 1 Hz after the button is pressed and indi cates the active programming mode The system is now in programming mode for approx 7 minutes Each time the start up button is pressed on a door or home sta tion the time is reset to 7 minutes i LED indicators on BUS devices The active programming mode is also signalled by the LED of various BUS devices such as the hands free feature home sta tion the Comfort home station with receiver or the surface mounted hands free feature home station An overview of the LED indication is found on Page 38 Exiting programming mode 1 Briefly press the Systemprogr button on the control device to exit the programming mode vy The yellow LED goes out Start up documentation For documentation on the home stations assigned to the call buttons please see the table on Page 40 There you enter the names homes in the sequence in which you will allocate the home stations later on One family house Assigning door station call button to home station To assign a door station call button to a home station proceed as follows ieee 7 1 Press the System prog button on the control device for 3s Dos Systemprogr au 3 seconds to start programming mode see Page 18 I 3 sfv 2 Press the call button on the door station for 3 seconds until M Meier Q you hear a short acknowledgement tone 4 c Y Y
9. home station with TFT colour display The terminating resistance on the TFT display of this home sta tion is set to No The suppressor is connected to the home station which is last or furthest away in the system to the BUS terminals parallel to the 2 wire bus Video System Resistor No EF OA Qo 2 ZV BUS system I er ji ET 2 Resistor Resistor Yes Yes VV Video distributor EF Suppressor Connection of several colour cameras When using several door stations with colour cameras the door stations are linked via video distributors In this case note that the output lines of the video distributor may not exceed 30 cm TS 1 Q F max 30 cm Control unit video Two colour cameras can be supplied via the video control device The third and if present the fourth colour camera requires a separate additional power supply 37 LED indicators on BUS devices 38 The LEDs of the hands free feature Comfort with receiver sur face
10. loads are connected The red berlast LE D indicates both short circuits and over loads The flashing duration of the LED corresponds to the time during which the bus voltage is deactivated when a fault occurs The LED then flashes eliminated or up to 5 seconds after the fault has been With a permanent overload or short circuit the bus voltage is switched off for approx 180 s after the third overload detection During this switch of phase the Systemprogr T r ffner progr and berlast LEDs flash The LEDs then flash for up to 180 seconds after the fault has been eliminated Systemprogr button If the Systemprogr button is pressed for 3 seconds the door communication system is switched to programming mode The yellow LED next to the programming button indicates the active programming mode via flashing see Page 18 T r ffnerprogr button The T r ffnerprogr button has two functions 1 Activating door opener programming mode the system is in programming mode the door opener pro gramming mode is activated see Page 22 The yellow LED next to the T r ffnerprogr button indi cates the active door opener programming mode via flashing 2 Actuation of the connected door opener Briefly pressing the T r ffnerprogr button activates the door opener for the set door opener time The yellow LED next to the T r ffnerprogr button illuminates during the switching
11. mounted hands free feature and surface mounted gong home stations indicate the system status LED button System status 0 or fl Programming mode active call buttons and or flashes gong not yet assigned Qor fl Programming mode active at least one call lights up button is already assigned to the home station or the gong Programming mode active home station lights up memory of occupied by 10 call buttons Occupied on the surface mounted hands free feature home station with 15 call buttons O Programming mode active lights up long automatic door opener enabled long short short automatic door opener disabled O ights up Automatic door opener activated A Comfort home station with receiver flashes signals incoming call 2 min A Comfort home station with receiver ights up a call is in progress EN Hands free feature and surface mounted flashes hands free feature home station signals incom 2 min ing call Hands free feature and surface mounted ights up hands free feature home station a call is in progress x ights up Call tone is deactivated The Standard home station with receiver has no LED Acknowledgement tones of Bus devices In programming mode the following conditions are indicated using acknowledgement tones Acknowl Meaning edgement tone Short tone e During assignment release button e While deleting no meaning continue
12. simultaneously when a door station call button is pressed a call button can be assigned to several max 3 home stations as follows 1 Press the System prog button on the control device for 3 seconds to start programming mode see Page 18 Press the call button to which the home stations are to be assigned at the door station for 3 seconds until you hear a short acknowledgement tone You will hear a long acknowledgement tone Go to the first home station Press the button for 3 seconds until you hear a short acknowledgement tone A long acknowledgement tone indicates successful assign ment Go to the door station and press the call button again for 3 seconds Go to the second parallel home station Press the G button for 3 seconds until you hear a short acknowledgement tone A long acknowledgement tone indicates successful assign ment Repeat Steps 4 and 5 to assign an additional parallel home station to the call button 6 Press the Systemprogr button on the control device to exit the programming mode Carry out a function test 27 Assigning several home stations to a floor call button zen m 3s o Systemprogr 8 i 6s 3 s aJ lt Teen g 1x O Systemprogr ae SEE 7 28 If several home stations are to be called simultaneously when a floor call button is pressed a floor call button can be assigned to several max 3 home stat
13. specialist trade installation company electrical specialist trade They will forward the devices to the Gira Service Center 41 42 43 Gira Giersiepen GmbH amp Co KG Elektro Installations Systeme Postfach 1220 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 191 www gira de info gira de GIRA 10 41 03 84 19 11
14. time T r ffnerzeit adjuster The activation time of the door opener is set continuously atthe T r ffnerzeit adjuster The setting time lies in the range 1 second to 10 seconds The potentiometer can be adjusted with a screwdriver with a3 mm blade Connection terminals of video control device L N Mains connection terminals L and N AC 230 V 50 Hz _L function earth line A function earth line was connected to this terminal for func tional purposes Lay the earth potential to the earth terminal with suitable cabling not a green yellow cable Bus Output for powering of the Gira door communication bus with regulated direct current 26 V DC 2 V 700 mA a Door opener output 230 V AC max 2 A A door opener which cannot be connected to the 12 VAC terminals due to its electrical val ues e g very low ohm or 24 V AC can be con nected to the equipoten tial bonding relay con tact with an external power supply 230 V AC max 2 A 12 V Door opener output 12 V AC a ea mA CC Function earth line The 12 VAC output is used to supply power to and control the door opener 8 12 V max 1 1 A i Not a continuous 12 V output Power is not continuously supplied at the door opener output The 12 V power supply at the door opener output is only present for the door opener time set at the adjuster Mounting of v
15. tone after 3 seconds Hold down the button for another 3 seconds until you hear a long acknowledgement tone ystemprogr 1x le R 3 Press the Systemprogr button on the control device to Oe exit the programming mode i Deletion only possible directly Deleting the assignment of a call button to a home station is not possible via the floor call button The deletion of the assign ment can only occur via the 6 button of the home station 30 Deleting assignment of door opener Door opener at video control device To delete an existing assignment between the door opener con nected at the control device and the door station proceed as fol lows ined T 6 s COC N r ftmerprogr 3 Szene 1 1x O Systemprogr a Sel 1 Press the System prog button on the control device for 3 seconds to start programming mode see Page 18 2 Press the T r ffnerprogr button on the control device for 6 seconds to delete all of the assignments from the control device to the door stations The LED starts flashing after 3 seconds Keep the button pressed for an additional 3 seconds until the LED next to the programming button T r ffnerprogr flashes rapidly 3 Press the Systemprogr button on the control device to exit the programming mode Door opener at switching actuator To delete an existing assignment between the door opener con nected at the switching actuator and the door stat
16. 2 34 Control unit video 3 Rule A video distributor is necessary at the branch end for an audio home station If a home station without the video function is located at the end of a cable line a video distributor must be inserted Resistor Resistor Rate No Me off 23232 fo WS 3 Audio WS 2 Video 22 ws 1 Video Sei u of ws2 jo H H 2 Outdoor station 2 2 a 2 VV Video distributor Control unit video Resistor Yes o o WS 4 Video WS 3 Audio 7 IH iz v EI Resistor ws4 Yes o WS 2 Video r WS Audio 2 Wao 2 2 Fal ol ws2 o ws 1 vv Al Outdoor station 2 VV Video distributor Control unit video 35 36 4 Rule If the video signal runs through 3 or more video distributors a suppressor must be used If the video signal runs through three or more video distributors in a topology a suppressor must be connected at the furthest
17. Operating Instructions System Manual Video Control Device 1288 0 GIRA Table of contents System information ara hice Honea edie ecient 4 Inst llation scenario topologies rss einen 6 Structure of a flush mounted door station with colour camera Structure of a surface mounted door station with colour camera 5 Structure of a home station with TFT display cccccsceccccccccesessssseeeeeeeceeeeseeteees The door communication DUS coupler cc cecccescceeccececccesnsssseeeeeeeeeceeesessstsaeeeeees EME WVIGEO COMO deV CE Se at een ee ee ep esgnsrer nee Displays and operating elements of video control device ne Connection terminals of video control device useenneeeeneneeennnnn Mounting of video Eontrol device munen nennen een Technical data of video control device Start up Switching system to programming mode 244ueseennenennennenneenneneennnnn 18 One family house Assigning door station call button to home station 19 House divided into several flats Assigning door station call buttons to homerstations ai n n en ner er HEHE 20 Assigning door opener emae s ee rn OES nee nen nee ent 22 Automatic door opener ieia e a a eE AAEE a EEEa E 24 Assigning home station via floor call button ennnennnn 26 Assigning several home stations to a call button ensnnennn 27 Assigning several
18. can be temporarily stored per step If more than 20 call buttons are to be assigned the first 20 call buttons must first be pressed and then assigned to the home stations The remaining call buttons can then be assigned 21 Assigning door opener 22 M Meier 7 q ZI So E Systemprogr 7 The door opener connected to the control device is assigned to the main door station It is activated if the O button at a home station is pressed spontaneously even without any previ ous conversation The door opener of a back side door is connected to the switching actuator It can be activated via the button if a door call was previously initiated from the door station of a back side door It is switched to the main door 2 minutes after the door call or 30 seconds after the door call Assigning door opener of main door The door opener connected to the control device is programmed at the respective door station as follows 1 Press the System prog button on the control device for 3 seconds to start programming mode see Page 18 2 Press the T r ffnerprogr button on the control device for 3 seconds to start the door opener programming mode v The LED next to the T r ffnerprogr button flashes w Press any call button on the door station for 3 seconds until you hear a short acknowledgement tone Y Along acknowledgement tone confirms successful assign ment In addition the door
19. ener function 1 Press the System prog button on the control device for 3 seconds to start programming mode see Page 18 2 Simultaneously press the buttons X and lt O on the home station for approx 3 seconds By pressing these buttons you can switch over the status of the automatic door opener enabled or disabled v Ifthe gt LED lights up long for confirmation the automatic door opener function is enabled If the LED lights up short for confirmation the auto matic door opener function is disabled 3 Press the Systemprogr button on the control device to exit the programming mode 3s If the automatic door opener function is enabled you can acti vate the automatic door opener as necessary on the home sta tion as follows Activating automatic door opener 1 Simultaneously press the buttons X and O on the home station for approx 3 seconds to activate the automatic door opener v When the automatic door opener is activated the LED lights up continuously The door opener is automatically operated after a door station call button is pressed Deactivating automatic door opener 1 Simultaneously press the buttons X and O on the home station for approx 3 seconds to deactivate the automatic door opener y The O LED goes out The automatic door opener is no longer active i Behaviour after a power failure The enabled status of the automatic door opener is retained
20. f call buttons is restored with this No further programming at the home sta tions is necessary 5 Press the Systemprogr button on the control device to exit the programming mode Carry out a function test If the call buttons were assigned in the wrong order repeat the procedure and press the call buttons in the reverse order Replacement of a door communication bus coupler When replacing a door communication bus coupler the system must be restarted i e access to the home station the floor call button is required Use of the video distributor configuration of the terminating resistance In order for the cable ends of the branches to have a defined ter minating resistance you can activate or deactivate the terminating resistance of a home station at the TFT display To activate it go to the menu item Widerstand in the TFT display menu and select the option Yes In general the terminating resistance must be activated at the last home station of a cable line This applies for both topology types i e looping through and branching Simple rules which are explained with examples exist for the configuration of the terminating resistance 1 Rule Always activate terminating resistance at branch end The terminating resistance must be activated at the TFT display for home stations located at the branch end Resistor Resistor
21. for the looping through solu tion The terminating resistance of WS1 and WS2 must be deac tivated see also Page 33 Structure of a flush mounted door station with colour camera The basic structure of a flush mounted door station with the video function is presented in the example of the flush mounted door station with video function with 3 gang call button and col our camera 4 5 6 7 8 EN EH 00000 00000 3 2 q 11 10 9 Door communication bus coupler Audio connection cable 6 pole Video connection cable 2 pole Speech insert Camera insert TX_44 cover frame bottom section Door speaker top unit Colour camera top unit 9 Call button cover plates 10 TX_44 cover frame top section 11 3 gang call button not incl in scope of supply AN onarRWNDN Structure of a surface mounted door station with colour camera The basic structure of a surface mounted door station with the video function is presented in the example of the surface mounted door station with colour camera and 3 gang call button
22. g actu ator is operated for the set time To assign additional door stations to the same door opener repeat Step 4 at the next door station 5 Briefly press the Progr button at the switching actuator to exit door opener programming mode of the switching actuator he LED of the Progr button goes out he LED of the last selected function Door opener in this example continues to flash until programming mode at the control device is exited 6 Press the Systemprogr button on the control device to exit the programming mode 23 Automatic door opener 350 SE Systemprogr 24 SE m Systemprogr a i Hands free feature and Comfort home station The function automatic door opener is only supported by the hands free feature home station and the Comfort home station with receiver The automatic door opener is for example used in doctor s offices when after pressing a door station call button the door opener is to be automatically operated With the automatic door opener activated the door opener assigned to the calling door station is operated approx 4 seconds after the door call is trig gered If several door stations are present in the system the automatic function automatically acts on the door opener of the door station from which the door call was triggered Before use the automatic door opener must first be enabled Enabling disabling automatic door op
23. home stations to a floor call button enne 28 Assigning call button for home station to a home station internal call 2429 Deleting all assignments to a home station eeneeneenmeeneennnnen 30 Deleting assignment of the door opener uunessneneneseennnennnenenennnneen 31 Replacement of defective call button top units of a flush mounted door station Use of the video distributor configuration of the terminating resistance 33 Connection of several colour CAMEFAS ccceeeececeeeeceeeeeeneeeeceeeeeeeeeuseeeteeureeeetas 37 LEB indic tors on BUS devices nn ana an 38 Acknowledgement tones of Bus devices ueeeeneeeesenenenennnnn nennen 39 Table for start up documentation nennen nam 40 Warranty System information The Gira door communication system operates with the voltage type SELV In systems with video components up to 18 home stations and two door stations with colour cameras can be connected to the 2 wire bus In systems with audio components systems with up to 70 audio devices can be realised with certain system configurations e g 1 Built in speaker with 5 add on modules and 68 Surface mounted hands free feature home station Depending on the system size a maximum of 3 home stations can be operated in parallel per call button i Planning software An exact determination of the maximum system size is possible
24. ideo control device A Attention Installation and mounting of electrical devices may only be car ried out by a qualified electrician For installation protected from dripping and sprayed water mount the control device to a top hat rail in the distribution The mains and bus connection is made via screw terminals The mains connection must be made via an all pole mains switch with at least a 3 mm contact opening The function earth line must be connected via a distributo block The ventilation slits of the control device must not be blocked Technical data of video control device Primary rated voltage Secondary rated voltage Secondary rated current Protection type Screw terminals Door opener output Door opener time Power on time of door opener Operating temperature Dimensions AC 230 V 50 Hz SELV 26VDC 2V 700 mA continuous load Overload deactivation from approx 900 mA 1 15 A peak load max 5 seconds IP 20 0 6 mm to 2 5 mm 12 V AC 1 1 A switched for the set door opener time adjustable 1 to 10 seconds 25 max 10 seconds ON then 30 seconds OFF 5 Cto 45 C 8 modules series inst housing Switching system to programming mode es 4 1 3 S Boe Systemprogr T ene 7 SE g Systemprogr The Gira door communication system is switched to program ming mode for start up 1 Press the Systemprogr button on the control device for 3 seconds v
25. ion proceed as follows Bist ae u 3s ec Systemprogr 1 ms es ER ee a 1x10 Systemprogr as Rt Press the System prog button on the control device for 3 seconds to start programming mode see Page 18 Press the Progr button on the switching actuator for 6 seconds to delete all of the assignments from the switch ing actuator to the door stations The LED starts flashing after 3 seconds Keep the button pressed for an additional 3 seconds until the LED next to the programming button T r ffnerprogr flashes rapidly 3 Press the Systemprogr button on the control device to exit the programming mode 31 Replacement of defective call button top units of a flush mounted door station Su 3 Ss BOE Systemprogr Bas S 7 6 s M Meier iON 1x O Systemprogr gt el r 32 You can replace defective door station call button top units at a flush mounted door station without having to reprogram the assignments 1 Replace all defective call button top units with new ones 2 Press the System prog button on the control device for 3 seconds to start programming mode see Page 18 Press any call button on the door station for 6 seconds to delete the existing assignments Press all call buttons on the door station one after another in the sequence of the first start up for 3 seconds to restore the assignments The replacement and the old assignment o
26. ions as follows 1 Press the System prog button on the control device for 3 seconds to start programming mode see Page 18 2 Press the floor call button connected to home station 1 for 6 seconds You will hear a brief acknowledgement tone after 3 seconds Hold down the button for another 3 seconds until you hear a long acknowledgement tone 3 Press the 8 button on home station 2 for 3 seconds until you hear a short acknowledgement tone v A successful teach in is confirmed by a long acknowledge ment tone at home station 2 To assign an additional home station repeat the procedure from Step 2 4 Briefly press the Systemprogr button on the control device to exit the programming mode 5 Carry out a function test All assigned home stations ring when the floor call button is pressed AN Do not connect floor call button in parallel A floor call button may not be connected to several home stations in parallel Assigning call buttons for home station to a home station internal call eta 3 s EO EAO WE r 3 alg e o q g 1x Systemprogr E ee r You can implement the so called internal call function with the optional call button for home stations A voice connection between two home stations can be established via the internal call To assign the call button of a home station to another home sta tion e g in the hobby room proceed as follows
27. llel home stations with TFT display are used one display must be defined as the main display and the others as second ary displays e Electronic overload and short circuit protection e electronic excess temperature protection e overload short circuit LED indicator e LED operation indication for determination of whether or not mains voltage is active adjustable activation time of door opener Displays and operating elements of video control device Jade OOO cf NN oO Systemprogr O 6 T r ffnerprogr T r ffnerzeit 1s 10s BUS give O Betrieb Uberlast GIRA T rkommunikations System Steuerger t Video 1288 00 LN BUS 12 V 4 r2 CE amp EUR 230 V 50 Hz 60VA 26V 2V 13 2VA ED 25 230 V 2 A max OLEACA GO0 QOO ceres Betrieb indicator During trouble free normal operation only the green Betrieb LED illuminates It indicates that the device is being supplied with power berlast indicator The video control device is equipped with an electronic overload protection which protects the electronics of the control device against short circuits and overloading on the bus line The overload protection is activated if for example the bus line is short circuited due to an installation error or too many bus devices bus
28. opener connected to the control device is operated for the set time To assign additional door stations to the same door opener repeat Step 3 at the next door station 4 Press the T r ffnerprogr button on the control device to exit door opener programming mode 5 Press the Systemprogr button on the control device to exit the programming mode a 3 s ERT B ae E 3s u Z 3s M Meier Si 7 Nw 1x 205 ee y g Systemprogr 2 Assigning door opener of a side back door The door opener connected to the switching actuator is pro grammed at the respective door station as follows 1 Press the System prog button on the control device for 3 seconds to start programming mode see Page 18 Briefly press the Function button on the switching actua tor several times until the T r ffner LED flashes Press the Progr button on the switching actuator for 3 seconds until the yellow LED next to the Progr button flashes Press any call button on the door station for 3 seconds until you hear a short acknowledgement tone i Releasing the button after 3 seconds If the button press is not ended after the first acknowledgement tone all assignments of the respective door home station will be deleted after an additional 3 seconds v Along acknowledgement tone confirms successful assign ment In addition the door opener connected to the switchin
29. ou will hear a long acknowledgement tone lt lt i Releasing the button after 3 seconds If the button press is not ended after the first acknowledgement tone all assignments of the respective door home station will be deleted after an additional 3 seconds until you hear a short acknowledgement tone vZ A long acknowledgement tone indicates successful assign m ment Three short acknowledgement tones indicate faulty assign ment The memory of the home station may already be occu pied A maximum of 10 call buttons can be assigned to a home station a maximum of 15 call buttons to a surface mounted hand free feature home station 3sl ola 3 Press the button on the home station for 3 seconds ystemprogr 1x 10 A syatemprogr 4 Press the Systemprogr button on the control device to L a exit the programming mode 5 Carry out a function test House divided into several flats Assigning door station call buttons to home stations 3s 3s 20 fi o Systemprogr as 1 To assign the door station call buttons to the respective home stations please proceed as follows 1 Press the System prog button on the control device for 3 seconds to start programming mode see Page 18 Press the call buttons on the door station for 3 seconds until you hear a short acknowledgement tone Important Press the call buttons in the sequence in
30. to hold down button Long tone e During assignment call button was assigned successfully e While deleting release button assignment is deleted 3 short tones During assignment call button was not assigned e Memory of door station for calling up learned in call buttons is occupied maximum of 20 call buttons e When assigning a door opener 3 door open ers were already assigned a call button cannot be assigned if e the home station memory is already occupied by 10 15 call buttons In this case the O LED of the hands free feature surface mounted hands free feature and Comfort with receiver home station lights up A maximum of 10 call buttons can be assigned to a home station a maximum of 15 call but tons to a surface mounted hands free feature home station e no call buttons at the door or home station were pressed be forehand e all previously pressed call buttons were already assigned to other home stations 39 Table for start up documentation Call button Home station Name Location Floor Taught in Number Name Meier 2nd floor left living room v 40 Acceptance of guarantee The warranty is provided in accordance with statutory require ments via the specialist trade Please submit or send faulty devices postage paid together with an error description to your responsible salesperson
31. video devices e g TFT colour display colour camera etc via the 2 pole connector i Rubber plugs in the connectors The second connectors are sealed with rubber plugs These plugs can be removed if necessary The video control device The video control device is the main power supply of the Gira d T d oor communication system he video control device assumes the following tasks in the Gira oor communication system provision of the bus voltage 26 V DC 2 V for the door com munication system Power supply for up to 2 colour cameras up to 4 colour cameras 2 with additional power supply can be operated per video control device Power supply of call button illumination max 15 the number of call button illuminations that can be supplied is dependent on the system size and the number of home stations operation in parallel provision of door opener control including power supply 12 VAC 1 1 A of the door opener activation of the programming mode from the entire door communication bus system Additional product features of the control device e In audio systems Up to 70 audio devices e g 1 built in speaker with 5 add on modules 68 surface mounted hands free feature home station e n video systems up to 18 home stations with TFT display and two door stations with colour cameras with max three paral lel home stations can be connected i Parallel home stations with TFT display If para
32. which the home stations will be assigned later You will hear a long acknowledgement tone i Releasing the button after 3 seconds If the button press is not ended after the first acknowledgement tone all assignments of the respective door home station will be deleted after an additional 3 seconds 3 Go to the home station whose call button is the first one you pressed at the door station Press the G button on this home station for 3 seconds until you hear a short acknowledgement tone A long acknowledgement tone indicates successful assign ment Three short acknowledgement tones indicate faulty assign ment The memory of the home station may already be occu pied A maximum of 10 call buttons can be assigned to a home station a maximum of 15 call buttons to a surface mounted hand free feature home station g Systemprogr 7 4 Go to the home station whose call button is the second one you pressed at the door station Press the 8 button on this home station for 3 seconds until you hear a short acknowledgement tone v Along acknowledgement tone indicates successful assign ment 5 Go to the other home stations and repeat Step 4 at each one 6 After you have assigned all the home stations press the Systemprogr button on the control device to exit pro gramming mode 7 Carry out a function test i Maximum number of call buttons per step Up to 20 call buttons

Download Pdf Manuals

image

Related Search

Related Contents

Tureis User Manual  Samsung SP-A8000 Benutzerhandbuch  Jenn-Air W10259841B User's Manual  FUNAI MBP5120F/F7 User's Manual  製品安全データシート  MANUAL DO USUÁRIO  Unified Services Router User Manual - D-Link  MA onPC command wing QuickMAnual  MSDS - BioChain  SCT 3000 Smartline Configuration Toolkit Model SCT 101  

Copyright © All rights reserved.
Failed to retrieve file