Operating Instructions Busch-Infoline 1563 U Busch warning signal

image

Contents

1. only be performed by authorised electricians Disconnect the mains power supply prior to installation and or disassembly Warning High sound pressure level High sound pressure level of 70 dB at a distance of 1 m Problems with concentration are possible in this area Safety distance must be adhered to 2 Intended use The device is to be used exclusively with the components that are supplied and licensed as described in chapter Setup and function 3 Environment Consider the protection of the environment Used electric and electronic devices must not be disposed of with domestic waste The device contains valuable raw materials which can be recycled Therefore dispose of the device at the appropriate collecting depot All packaging materials and devices bear the markings and test seals for proper disposal Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies The products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive 2002 96 EC WEEE and 2002 95 EC RoHS EU REACH ordinance and law for the implementation of the ordinance EC No 1907 2006 Operating Instructions 1473 1 8302 3 Operating Instructions m a Je Io y L e Q ra Y vu T A E A A Sa DUSCN ntoline 4 Technical data Nomin
2. 1473 1 8302 Rev 01 17 12 2012 Operating Instructions Busch Infoline 1563 U Busch warning signal insert 1564 U Light signal insert O BUSCH JAEGER Y Operating their wack D Busch Infoline 1 SA A ee E E E ee ee A A E T EE se 3 2 A ee ee ee 3 3 A O ee ee ee a sen 3 4 o o A N 4 5 SCO ANTICO ee ee A A 4 5 1 Features or TUNCTION and equipe erat ee 4 5 1 1 BUSCH Alar SIGMalINSEIEN DGS Usenet 4 5 1 2 EIONESIgNaliNnser 1564 VE E ia boa 4 5 2 POSSIDIE COMDPINAIIONS a a ad eo dto o 5 6 Installation and electrical connection ecesas E E EEE aE 6 6 1 Requirements for the electrician ooccccconcncoconnncocononononnnnononnnnonononnnnaronononnnnononnnnnnanannnnnrnnorannnnonananennos 6 6 2 Eleciical connection eiserne einlesen nee 7 6 3 MOUNTING ine device IAS a o nese 8 6 4 Setting acoustic signalling with jumper applies only to 1563 U oocccccccccccccncncccononocononnnconnnnnonnnnononnnnos 8 6 5 Setting signal sequence with jumper applies only to 1563 U occconcncccccnnccconcnccconnnoconcnnnnonnnnnnanononononoss 9 Operating Instructions 1473 1 8302 2 Operating Instructions pa a R i WV Dm e a o D LILICA Un A TA A fr eS AT TU S MG u Y N EI U EI ENG Bu YY j a Df l nz aw LA Y NS BE LIENSY Il SI w LA Ay A Y 1 Safety Warning Electric voltage Risk of death and fire due to electrical voltage of 230 V Work on the 230V supply system may
3. B Group Busch Jaeger Elektro GmbH PO box 58505 L denscheid Freisenbergstra e 2 58513 L denscheid Germany www BUSCH JAEGER com info bje de abb com Central sales service Phone 49 0 2351 956 1600 Fax 49 0 2351 956 1700 Notice We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or extracts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB Copyright 2012 Busch Jaeger Elektro GmbH All rights reserved BUSCH JAEGER lt I9 1473 1 8302 Rev 01 17 12 2012
4. Fig 1 Circuit diagrams for Busch Alarm signal insert and light signal insert 1 NO contact for alarm activation Terminal assignment Busch Alarm signal insert 1563 U light signal insert 1564 U Terminal designation Assignment nc Not occupied 3 Triggering the optical and acoustic alarm signal 15 V AC for alarm activation Operating Instructions 1473 1 8302 7 Operating Instructions Busch Infoline Installation and electrical connection 6 3 Mounting the device insert 1 Mount the devices in a flush mounted box according to DIN 049073 1 2 Fix the devices in the flush mounted box with screws 3 Mount the elements of the cover plate in the sequence shown in the illustration Le esiiita gt AO SO SNe el nr et bung ON 3 e mu to Fig 2 Overview of installation 6 4 Setting acoustic signalling with jumper applies only to 1563 U Fig 3 1563 U Busch Alarm signal insert Position Acoustic signaling Jumper top Acoustic signalling off Jumper bottom Acoustic signaling on Operating Instructions 1473 1 8302 8 Operating Instructions 6 5 Setting signal sequence with jumper applies only to 1563 U Fig 4 1563 U Busch Alarm signal insert e bottom u if N sec M5 sec SZ NON perman No 3 sec 0 3 sec amp X MAMMA No 3 sec 0 3 sec Operating Instructions 1473 1 8302 Operating Instructions Busch Infoline A member of the AB
5. al voltage 9 5 28 VAC 9 5 35VAC Rated frequency 50 60 Hz Nominal current 60 mA AC 30 mA DC Sound pressure applies only to 1563 U 70dB 1m Sound frequency applies only to 1563 U 2 3 kHz Protection class IP 20 Type of protection for device SELV Operating temperature range 5 40 C 5 Setup and function 5 1 Features of function and equipment 5 1 1 Busch Alarm signal insert 1563 U For optical and acoustic alarm signalization Type of signalling call alarm call in accordance with DIN VDE 0834 selectable via internal jumper Acoustic signalling via the internal jumper can be deactivated Alarm activation is triggered by applying the operating voltage Alarm signal Acoustic and optical signal according to DIN VDE 0834 in discontinuous change switch off function Permanent acoustic and optical signal or with interruption 5 1 2 Light signal insert 1564 U The insert serves for optical alarm status signal The light signal lights up at a permanent alarm Alarm activation is triggered by applying the operating voltage Alarm signal Permanent light signal Operating Instructions 1473 1 8302 Operating Instructions Busch Infoline Setup and function 5 2 Possible combinations Busch warning signal f l Light signal insert insert 1531 U 1573 C 21x 1573 C 21x 1573 CN 84 1573 CN 84 Operating Instructions 1473 1 8302 5 Operating Instructions Busch Info
6. line installation and electrical 6 Installation and electrical connection Warning Electric voltage Risk of death due to electrical voltage of 230 V during short circuit in the low voltage line Low voltage and 230 V lines must not be installed together in a flush mounted socket 6 1 Requirements for the electrician Warning Electric voltage Install the device only if you have the necessary electrical engineering knowledge and experience e Incorrect installation endangers your life and that of the user of the electrical system e Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows e Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect from power 2 Secure against being re connected 3 Ensure there is no voltage 4 Connect to earth and short circuit 5 Cover or barricade adjacent live parts e Use suitable personal protective clothing e Use only suitable tools and measuring devices e Check the supply network type TN system IT system TT system to secure the following power supply conditions classic connection to ground protective earthing necessary additional measures etc Operating Instructions 1473 1 8302 6 Operating Instructions Busch Infoline Installation and electrical connection 6 2 Electrical connection Circuit diagrams A A 1 1