1. 0 025 A IP 66 20 C a 40 C 50 C 40 C a 80 C env 6 2 kg 3 x 2 5 mm mod le standard M20x1 5 pour c bles d un mod le standard d un de 5 5 13 mm M20x1 5 3 75 Nm 2 5 Nm pour tancher le c ble ou le bouchon de fermeture Tolerances admissible selon CEI EN 60079 0 4 Installation EXIT 2 A Lors de l installation et de l exploitation des appareils lectriques pour atmosph re explosive les r glements nationaux ainsi que les r gles de la technique g n ralement reconnues doivent tre respect s Le transport et le stockage ne sont permis que dans l emballage original et dans la position sp cifi e 4 1 Ouverture et fermeture du panneau J Desserrez les quatre vis du couvercle J Le couvercle peut tre ouvert pour les charni res moul s Pour faciliter l installation le couvercle peut tre enlev sur les charni res Enlevez le couvercle Posez le couvercle sur une surface propre et lisse afin de ne pas rayer la s rigraphie du couvercle 4 2 Montage du panneau Le panneau doit tre correctement fix l aide des quatre pattes de fixation avec des vis appropri es vis maximum 5 mm fig 1 sur un support solide 4 3 Raccordement au secteur Ouvrez le couvercle comme d crit Faites passer le c ble d alimentation secteur dans le passe cable marqu M 20x1 5 Utilisez pour les cables de 5 5 8 mm les deux inserts d tan ch it pour les cables de 8 13 mm
2. Betreiben von explosionsgesch tzten elektrischen Betriebs mitteln geltenden Sicherheitsvorschriften gem des Ger tesicherheitsgesetzes sowie die allgemein anerkannten Regeln der Technik sind einzuhalten EN IEC 60079 14 Transport und Lagerung der Leuchte ist nur in Originalverpackung und der angegebenen Lage gestattet 4 1 ffnen und Schlie en der Leuchte L sen sie die vier Deckelschrauben Schlitz SW4 mm Die Haube kann an den angespritzen Scharnieren aufgeklappt werden Zur leichteren Montage kann die Haube aus den Scharnieren ausgeh ngt werden Beim Ablegen der Haube auf glatte und saubere Unterlage achten damit der Siebdruck auf der Haube nicht verkratzt wird 4 2 Montage der Leuchte Die Leuchte ist an den vier Befestigungspunkte mit geeigneten Befestigungsschrauben Schraube max 5 mm Bild 1 sicher auf tragf higem Untergrund anzuschrauben 4 3 Netzanschluss Haube wie beschrieben ffnen F hren Sie die Netzzuleitung durch die bescheinig te Leitungseinf hrung M20x1 5 ein Verwenden Sie f r Leitungen von 5 5 bis 8 mm beide Dichtungseins tze von 8 bis 13 mm nur den u eren Dichtungseinsatz Achten Sie auf korrekten Sitz des verbleibenden Dichtungseinsatzes in der Verschraubung Bei nicht benutzten Kabel und Leitungseinf hrun gen ist die Schutzscheibe zu entfernen und durch einen bescheinigten Verschlussstopfen Drehmo ment 3 5 Nm zu verschlie en Beim Verschlie en mit einem bes
3. Bild 4 1 20 am Adressschalter einzustellen Pfeil auf Zahl Bild 3 Soll die Leuchte nicht berwacht werden ist immer die Stellung 0 0 einzustellen Die Standardleuchte EXIT 2 ist nicht mit einer Uberwachungselektronik ausger stet und ist nicht adressierbar 6 Inbetriebnahme vor der Inbetriebnahme die korrekte Funktion und Installation der Leuchte in bereinstimmung mit dieser Betriebsanleitung und anderen zutreffenden Bestimmungen berpr fen Isolationsmessungen nur zwischen PE und Au en leiter L sowie zwischen PE und N durchf hren Messspannung max 1kV AC DC Messstrom max 10 mA N Achtung Eine Isolationsmessung zwischen L und N darf nicht durchgef hrt werden da sonst die Elektronik oder die Netzeingangs sicherung im Ger t zerst rt wird Cooper Crouse Hinds GmbH 7 Instandhaltung Andie fur die Instandhaltung Wartung und Prufung von explosionsgeschutzten Betriebs mitteln geltenden Bestimmungen z B EN IEC 60079 17 sind einzuhalten 7 1 Wartung Im Rahmen der Wartung sind vor allem die Teile von denen die Z ndschutzart abh ngt zu pr fen z B Geh use und Schutzwannen auf Risse und Besch digungen Dichtungen auf Besch digungen Klemmen und Verschluss Stopfen auf festen Sitz Wegen der Gefahr elektrostatischer Aufladung darf die Leuchte nur mit einem feuchten nicht fasernden Tuch oder Schwamm gereinigt werden Dazu nur bliche Haushaltssp lmittel in vorgesch
4. amp CEAG Explosionsgeschutzte LED Rettungszeichenleuchte Serie EXIT 2 EXIT 2 24 V und EXIT 2 CG S Zone 2 22 Explosion protected LED EXIT 2 luminaire Series EXIT 2 EXIT 2 24 V and EXIT 2 CG S zone 2 22 Panneau de signalisation de sortie de secours lumineux antid flagrant a diodes lectrolumi nescentes Serie EXIT 2 EXIT 2 24 V et EXIT 2 CG S Zone 2 22 32193000061 D E F Betriebsanleitung Operating instructions Mode d emploi e COOPER Crouse Hinds COOPER Crouse Hinds GmbH Neuer Weg Nord 49 D 69412 Eberbach Germany Fone 49 0 6271 806 500 Fax 49 0 6271 806 476 Internet http www CEAG de E Mail sales cch de cooperindustries com MaBbilder Dimensional drawings Dimensions Bild 1 fig 1 Fig 1 Befestigungsschrauben Fixing screws vis de fixation 5 mm Pfeil Arrowhead Fl che Bild 2 fig 2 Fig 2 Bild 2a Bild 3 fig 3 Fig 3 Netzanschluss Netzanschluss 24 V DC Mains connection Mains connection 24 V DC sch ma des connexions sch ma des connexions 24 V CC P COOPER Crouse Hinds 1 Sicherheitshinweise Zielgruppe Elektrofachkrafte und unterwiesene Personen EN IEC 60079 14 Die Leuchte darf nicht in der Zone 0 1 oder 20 21 eingesetzt werden Die auf der Leuchte angegebenen techni schen Daten sind zu beachten Die Anfo
5. d claration de conformit jointe s par ment Compatibilit ectromagnetique 2004 108 CEE Il a t con u construit et test selon l tat actuel de la technique et selon EN ISO 9001 2008 et IEC 80079 34 2011 Position de Position de Adresse de l interrupteur 1 l interrupteur 2 luminaire O O aucune surveillance O 1 1 O 2 2 1 0 10 d 1 11 2 O 20 2 1 pas possible 9 9 pas possible Fig 4 Adressage P COOPER Crouse Hinds 3 Caract ristiques techniques Certificat d essai CE du mod le type Domaine d application 94 9 CE et directive EN 60079 0 ta 40 C ta 90 C Gamme des tensions CA EXIT 2 24 V EXIT 2 EXIT 2 CG S Gamme des tensions CC EXIT 2 24V EXIT 2 EXIT 2 CG S Gamme des fr quences Courant nom 110 V CA CC 230 V CA CC Classe d isolation selon CEI EN 60598 Indice de protection selon CEI EN 60529 Temp rature ambiante Dautres temp ratures sont possibles avec des mod les sp ciaux Temp rature de stockage dans l emballage original Poids Capacit de serrage des bornes 2 x par borne Entr e de c ble Ex e fils de m tal Couple d essai pour l entr e de cable Ex e M20x1 5 Couple d essai pour la vis de pression CCH 13 ATEX 1019 amp 113 G Ex eic mc IIC T5 Gc amp 113 G Ex eic mc IIC T4 Gc 113 D Ex tc IIIC T80 C Dc WAGONS 277 V gt 220 V 254 V 12 24V 15 20 110 V 250 V 195 V 250 V 50 60 HZ 0 05 A
6. d tach es agr es d origine CEAG CCH voir liste des pieces d tach es CEAG CCH Des modifications ou extensions de programmes font l objet de r serves Respectez les prescriptions l gales de traitement des d chets en cas d limination Technische Anderungen vorbehalten Betriebsanleitung g ltig ab 38 2013 32193000061 XX 38 13 Str
7. de l clairage de secours CEAG raccord le fonctionnement de l lectronique d alimentation ainsi que le fonctionnement d au moins 50 des LED Avec le module de surveillance CG S quip d un commutateur de codage pour un maximum de 20 adresses l afficheur EXIT 2 CG S peut tre exploit comme afficheur de secours unique contr l reli aux syst mes d alimentation d clairage de secours CEAG L exploitant peut dans ce cas programmer librement le mode de commutation Jusqu a 20 afficheurs peuvent tre exploit s avec diff rents modes de commutation dans un circuit lectrique terminal 5 1 Adressage L adressage individuel des afficheurs doit tre effectu avant le montage du couvercle du panneau de l afficheur Pour cela proc dez au r glage des adresses souhait es fig 4 1 20 au commutateur d adresses l aide d un tournevis appropri fl che face aux nombres fig 3 Si l afficheur ne doit pas tre surveill r gler toujours la position sur 0 0 Le panneau d affichage standard EXIT 2 n est pas quip d une lectronique de surveillance et n est pas adressable 6 Mise en service ZN V rifiez que l installation et le fonctionne ment corrects de l afficheur soient conformes aux instructions de cette notice d utilisation et toutes les autres prescriptions en vigueur Les mesures d isolation ne doivent tre effectu es qu exclusivement entre PE et les c bles ext
8. rieurs L ainsi qu entre PE et N Tension de mesure maximum 1kV AC DC Courant de mesure maximum 10 mA N Attention ne pas effectuer de mesure d isolation entre L et N sinon il y a destruction de l lectronique ou du fusible de protection d alimentation secteur de l appareil 7 Entretien N Respectez la r glementation en vigueur en ce qui concerne l entretien la maintenance et le contr le des moyens d exploitation antid flagrants par ex CEI EN 60079 1 7 7 1 Maintenance ll faut avant tout v rifier les pi ces desquelles d pend le type de protection antid flagrante par ex J Fissures et dommages au bo tier et au carter de protection J Dommages aux joints J Positionnement correct des borniers et des bouchons de fermeture J En raison du risque de charge lectrostatique le panneau ne doit tre nettoy qu a l aide d un chiffon non pelucheux ou d une ponge humides N utilisez pour cela que des produits de rin age m nagers dilues dans de l eau la concentration prescrite La temp rature de l eau ne doit pas d passer 50 C Rincez ensuite l eau claire sinon il y a risque de fissures de tension dans le carter de protection 7 2 R paration Respectez les instructions suivantes avant le remplacement ou le d montage de pi ces d tach es Mettre d abord le panneau hors tension avant toute ouverture ou travaux de r paration N utilisez que des pi ces
9. seulement l insert d tanch it ext rieur Veillez l assise correcte des inserts d tanch it restants dans l assemblage viss En cas de non utilisation de c bles ou de passe c bles la rondel le de protection doit tre retir e et remplac e par un bouchon de fermeture homologu couple de serrage 3 5 Nm Utilisez toujours les deux inserts d tanch it lors de la fermeture avec le bouchon homologue En cas de passe c ble en m tal les capuchons de protection des passe c bles non utilis s doivent tre enlev s et remplac s par des bouchons de fermeture antid flagrants homolo gu s minimum IP66 IN Attention Seul un c blage fixe est autoris Dans le cas d utilisation d autres passe c bles respectez les instructions du fabricant en ce qui concerne le serrage des c bles et l absence de tension m canique sur ceux ci Cooper Crouse Hinds GmbH 7 Cooper Crouse Hinds GmbH Neuer Weg Nord 49 D 69412 Eberbach Phone 49 0 6271 806 500 Fax 49 0 6271 806 476 Internet www CEAG de E Mail sales cch de cooperindustries com Raccordez s rement les c bles L N et PE au bornier fig 2 Montez la carte a LED Veillez a une pose correcte et sure des cables Evitez tout pincement des cables Monter le couvercle avec les quatre vis Les vis ne doivent tre serr es qu a la main 5 Surveillance EXIT 2 CG S Le module CG S surveille et signale au systeme d alimentation
10. 1 2 O 20 2 1 nicht zul ssig 9 9 nicht zul ssig Bild 4 Adresssierung EXIT 2 CG S P COOPER Crouse Hinds 3 Technische Daten EG Baumusterpr fbescheinigung Konformit t gem Richtlinie 94 9 EG und Norm EN 60079 0 ta ta 40 C 50 C a a Bemessungsspannung AC EXIT 2 24 V EXIT 2 EXIT 2 CG S Bemessungsspannung DC EXIT 2 24 V EXIT 2 EXIT 2 CG S Bemessungsfrequenz Bemessungsstrom 110 V AC DC 220 V AC DC Schutzklasse nach EN IEC 60598 Schutzart nach EN IEC 60529 zulassige Umgebungstemperatur Abweichende Temperaturen sind bei Sonderversionen m glich Lagertemperatur in Originalverpackung Gewicht mit Batterie Klemmverm gen Anschlussklemme 2x je Klemme Ex e Kabel und Leitungseinf hrung Standardausf hrung Metall Drehmoment f r Ex e Kabel und Leitungseinf hrung M20x 1 5 Drehmoment f r Druckschraube CCH 13 ATEX 1019 113G Ex eic mc IIC T5 Gc amp 113G Ex eic mc IIC T4 Gc 113 D Ex tc IC T80 C Dc nicht zulassig 110 V 277 V 220 V 254 V 12 24 V DC 15 20 110 V 250 V 195 V 250 V 50 60 Hz 0 05 A 0 025 A IP 66 20 C bis 40 C 50 C 40 C bis 80 C ca 2 2 Kg 3 x 2 5 mm M20x1 5 f r Leitungen 5 5 bis 13 mm M20x1 5 Gewinde 3 75 Nm 2 5 Nm f r Abdichtung Leitung oder Verschluss Stopfen x zul ssige Toleranzen gem EN 60079 0 4 Installation EXIT 2 Die f r das Errichten und
11. GmbH 5 Monitoring only EXIT 2 CG S The CG S module monitors and indicates to the connected CEAG emergency supply system the operation of the supply unit circuit and the function of min 50 of the installed LEDs The CG S module allows single monitoring of these luminaires in CEAG emergency lighting systems The switching mode maintained non maintained and switched emergency luminaires is freely programmable and mixed operation up to 20 addresses in a single circuit is possible 5 1 Addressing Before fitting the cover the addressing of the individual luminaires is to be carried out The desired address fig 4 1 20 is set on the address switch by means of a suitable screw driver Arrowhead to No fig 3 If the luminaire should not be monitored the code 0 0 has to be selected The standing luminaire EXIT 2 and is not equipped with monitoring circuit and can not be addressed 6 Taking into operation A Prior to operation check the light fitting for its proper functioning and installation in compliance with these operating instructions and other applicable regulations Only carry out insulation measurements between PE and the external conductor L as well as between PE and N measuring voltage max 1 kV AC DC measuring current max 10 mA N Mind There must no insulation measure ment be carried out between L and N since that would destroy the electronics mains input fuse in the unit 7 Mai
12. ake care to prevent scratches on the silk screen cover 4 2 Installation of the fitting The luminaire shall be fitted by using the four mounting clips with suitable fixing screws 5 mm fig 1 onto a suitable surface 4 3 Mains connection Open the cover as described Pass the cable 5 5 to 13 mm through the certified Ex cable entry M 20 x 1 5 Use both sealing inserts for cables from 5 5 to 8 mm and the outer sealing insert only for cables from 8 to 13 mm Pay attention to the proper fit of the remaining sealing insert in the certified cable gland In case of unused cable entries remove their protective cover and close the entries with a blanking plug torque of 2 5 Nm When closing the gland with a blanking plug always use both sealing inserts When metal cable entries are used the protective caps of the unused entries are to be removed and the entries to be closed with certified Ex blanking plugs A attention Only fix laid cable may be used for connection If cable glands from other manufacturer are used the instructions regarding strain relief and clamping capacity must be observed Connect the conductors to the terminals L N and PE in accordance with the terminal marking see fig 2 Remonte the LED printed board into the housing Take care not to pinch any conductors Install the protective cover with the four screws Tighten the screws only hand tight Cooper Crouse Hinds GmbH 5 Cooper Crouse Hinds
13. cheinigten Verschlussstopfen stets beide Dichtungseins tze verwenden Bei Metall Kabeleinf hrungen sind die Schutzkap pen der nicht benutzten Einf hrungen zu entfernen und durch bescheinigte Ex Verschlussstopfen min IP66 zu verschlie en N Achtung Nur festverlegte Leitungen zul ssig Bei Verwendung anderer Leitungseinf hrungen sind die Angaben des Herstellers hinsichtlich Klemmverm gen und Zugentlastung zu beachten Cooper Crouse Hinds GmbH B Klemmen Sie die Leitungen L N und PE am Klemmstein sicher an Bild 2 Achten Sie auf sichere Lage der Leitungen Quetschen Sie keine Leitungen Montieren Sie die Haube mit den vier Schrauben Ziehen Sie die Schrauben nur handfest an 5 Uberwachung EXIT 2 CG S Das CG S Modul berwacht und meldet an das angeschlossene CEAG Notlichtversorgungssys tem die Funktion der Versorgungselektronik sowie den Betrieb von min 50 der LEDs Mit dem CG S Uberwachungsmodul mit Codierschalter fur max 20 Adressen kann die EXIT 2 CG S Leuchte als einzeluberwachte Notleuchte an CEAG Notlichtversorgungssyste men betrieben werden Hierbei kann der Betreiber die Schaltungsart frei programmieren So k nnen an einem Endstromkreis bis zu 20 Leuchten in unterschiedlichen Schaltungsarten betrieben werden 5 1 Adressierung Vor Montage der Leuchtenhaube muss die individuelle Leuchtenadressierung eingestellt werden Hierzu ist mit einem geeigneten Schraubendreher die gew nschte Adresse
14. ency Rated current 110 V AC DC 230 V AC DC Insulation class to IEC EN 60598 Degree of protection accd IEC EN 60529 Operation temperature Deviating temperatures possible with special versions Storage temperature in original packing Weight Supply terminal clamping capacity 2 X per terminal Ex e cable entry standard version metal thread Test torque for M 20 x 1 5 Ex e cable entry Test torque for pressure screw for sealing off the cable or the blanking plug amp 113 G Ex eic mc IIC T5 Gc amp 113 G Ex eic mc IIC T4 Gc 113 D Ex tc IIIC T80 C Dc non permissible 110 V 277 V 220 V 254 V 12 24 V DC 15 20 110 V 250 V 195 V 250 V 50 60 HZ 0 05 A 0 025 A IP 66 20 C to 40 C 50 C 40 C to 60 C approx 2 2 kg 3 X 2 5 mm M20x1 5 for cable 5 5 to 13 mm M20x1 5 3 75 Nm 2 5 Nm max permissable tolerances accd IEC EN 60079 0 4 Installation EXIT 2 NThe respective national regulations as well as the general rules of engineering which apply to the installation and operation of explosion protected apparatus will have to be observed Transport and storage of the luminaire is permitted in original packing and specified position only 4 1 Opening and closing the light fitting Unscrew the four screws of the cover The cover can be opened to the molded hinges For ease of installation the cover can be removed out of the hinges If putting down t
15. ment Repairs that affect the explosion protection see national standard may only be carried out by CEAG CCH or a qualified electri cian Do not keep these operating instructions inside the light fitting during operation The national safety rules and regulations for prevention of accidents and the following safety instructions which are marked with an in these operating instruction will have to be observed 2 Conformity with standards The luminaire is suitable for use in zone 2 and 22 hazardous areas acc to EN IEC 60079 10 1 and EN IEC 60079 10 2 The luminaire is conform to the standards specified in the EC Declaration of conformity enclosed separately It has been designed manufactured and tested according to the state of the art and to DIN EN ISO 9001 2008 and IEC 80079 34 2011 The luminaire fulfil further requirements Such as the EC directive on electromagnetic compatibility 2004 108 EC Address Address Luminaire switch 1 switch 2 address O O Monitoring off O 1 1 O 2 2 1 O 10 1 1 11 2 O 20 2 1 not permissable 9 9 not permissable Fig 4 Addressing P COOPER Crouse Hinds 3 Technical data EC type examination certificate CCH 13 ATEX 1019 Category of application aacd 94 9 EC and directive EN 60079 0 ta a 40 C ta 50 C Rated voltage AC EXIT 2 24 V EXIT 2 EXIT 2 CG S Rated voltage DC EXIT 2 24 V EXIT 2 EXIT 2 CG S Rated frequ
16. ntenance NObserve the national regulations applicable to the maintenance servicing and test of appa ratus for explosive atmospheres e g IEC EN 60079 17 as well as the general rules of engineering 7 1 Servicing When servicing in particular those components that affect the explosion protection will have to be checked e g Housing and protective bowl for any cracks or damages Gaskets for their perfect condition Terminals and blanking plugs for their firm fit Because of the risk of an electrostatic charge the light fitting shall only be cleaned with a damp non fibrous cloth or sponge Only use customary household washing up liquid diluted in water as specified The water temperature may be max 50 C After that rinse with clear water to prevent the risk of tension cracks in the protective bowl 7 2 Repair Prior to replacing or removing any components observe the following Cut the apparatus off the voltage before opening it or carrying out repairs Only use certified genuine CEAG CCH spare parts Gee CEAG CCH spare parts list Subject to alteration or supplement of this product series Regarding waste disposal observe the relevant national regulations The plastic materials are marked with material identifications COOPER Crouse Hinds 1 Consignes de s curit Pour le personnel lectricien qualifi et le personnel instruit suivant la r gle mentation l gale y compris les no
17. rderungen der EN IEC 60079 31 u a in Bezug auf berm ige Staubablage rungen und Temperatur sind vom Anwender zu beachten Umbauten oder Ver nderungen an der Leuchte sind nicht zul ssig Die Leuchte ist bestimmungsgem in unbesch digtem und einwandfreiem Zustand zu betreiben Als Ersatz d rfen nur Originalteile von CEAG Cooper Crouse Hinds GmbH CCH verwendet werden Reparaturen die den Explosionsschutz betreffen durfen nur von CEAG CCH oder einer qualifizierten Elektrofachkraft durch gef hrt werden Diese Betriebsanleitung w hrend des Betriebes nicht in der Leuchte lassen Die nationalen Unfallverh tungs und Sicherheitsvorschriften und die nachfolgen den Sicherheitshinweise die in dieser Betriebsanleitung mit einem gekennzeichnet sind beachten 2 Normenkonformit t Diese Leuchte ist zum Einsatz in explosionsgef hr deten Bereichen der Zone 2 und 22 gem EN 60079 10 1 und EN 60079 10 2 geeignet Sie wurde entsprechend dem Stand der Technik und gem DIN EN ISO 9001 2008 und IEC 80079 34 2011 entwickelt gefertigt und gepr ft Weitere Anforderungen wie die Richtlinie Elektromagnetische Vertr glichkeit 2004 108 EG werden von der Leuchte erf llt Diese Leuchte entspricht den aufgef hrten Normen in der separat beigelegten Konformit ts erkl rung Adressschalter 1 Adressschalter 2 Leuchtenadresse O O berwachung aus O 1 1 O 2 2 1 O 10 1 1 1
18. riebener Verd nnung mit Wasser benutzen Die Wassertemperatur darf maximal 50 C betragen Anschlie end mit klarem Wasser nachsp len da sonst Spannungsrisse in der Schutzwanne entstehen k nnen 7 2 Instandsetzung Vor dem Austausch oder der Demontage von Einzelteilen ist folgendes zu beachten Das Betriebsmittel vor dem ffnen oder vor Instandhaltungsarbeiten erst spannunggfrei schalten Nur zugelassene CEAG CCH Originaler satzteile verwenden siehe CEAG CCH Ersatzteil liste Programm nderungen und erg nzungen sind vorbehalten Bei der Entsorgung nationale Abfallbeseitigungs vorschriften beachten COOPER Crouse Hinds 1 Safety instructions For skilled electricians and instructed personnel in accordance with national legislation including the relevant standards and where applicable in acc with IEC EN 60079 14 on electrical apparatus for explosive atmospheres The light fitting must not be operated in zone 0 1 or 20 21 hazardous areas The technical data indicated on the light fitting are to be observed The requirements of the IEC EN 60079 31 regarding excessive dust deposits and temperature to be considered from the user Changes of the design and modifications to the light fitting are not permitted The light fitting shall be operated as intended and only in undamaged and perfect condition Only genuine CEAG Cooper Crouse Hinds GmbH CCH spare parts may be used for replace
19. rmes respectives ainsi que le cas ch ant CEI EN 60079 14 pour apppareils lectriques utilisables en atmosphere explosive All n est pas permis d utiliser le luminaire dans la zone 0 1 et 20 21 Les caract ristiques techniques indiqu es sur le luminaire doivent tre respect es Les exigences des CEI EN 60079 31 en ce qui concerne des d p ts de poussi re d mesur s et une temp rature doivent tre consid r es par l utilisateur All n est pas permis de transformer ou de modifier le luminaire Le luminaire ne doit tre exploit que pour la fonction qui lui est d volue et qu en tat intact et parfait Seules des pi ces de rechange d origine CEAG Cooper Crouse Hinds GmbH CCH doivent tre employ es pour le remplace ment Des r parations qui portent sur la protection contre l explosion ne doivent tre ex cut es que par CEAG CCH ou par un lectricien qualifi Ce mode d emploi ne doit pas tre laiss dans le luminaire pendant son exploitation Veuillez respecter les prescriptions nationa les de s curit et de pr voyance contre les accidents ainsi que les consignes de s curit qui sont marqu es d un dans ce mode d emploi 2 Conformit avec les normes Ce luminaire convient l utilisation dans les zones 2 et 22 d une atmosphere explosive selon CEI EN 60079 10 1 et CEI EN 60079 10 2 Ce luminaire sont conformes aux normes reprises dans la
Download Pdf Manuals
Related Search
Related Contents
8・9ページ Terminos y Condiciones de Uso INTRANET Gérer son équilibre nutritionnel après les fêtes de fin d`année 10.01 Toshiba MK1661GSYN hard disk drive Fujitsu PRIMERGY TX100 S2 A quoi sert un projet pédagogique Manual - Nintendo of Europe 「オーロラブラック」の生層促進技術 取扱説明書 Kat. Nr. 60.2521 Copyright © All rights reserved.