1. up down switch photocells Technical documentation 21 Assembly and Operating Instructions BR 100 E Roller Door white green 44 1 black blue E brown PE yellow and green N E wires 5 brown W white G green Y yellow P gray 120 O 24U COM NO Auto closina SN Opening onl Fast manipulation Manipulator H stop O opening C closing Seauential A power supply T 3 zn z Aerial ooooooooonu
2. 29 Technical documentation Assembly and Operating Instructions BR 100 E Roller Door 62 1 63 1 S on the left servomotor on the right P1 top position adjustment switch mm bottom position adjustment switch P2 bottom position adjustment switch M top position adjustment switch 30 Technical documentation Assembly and Operating Instructions BR 100 E Roller Door INCORRECT ADJUSTMENT CORRECT ADJUSTMENT INCORRECT ADJUSTMENT switch activated too late switch activated on time switch activated too early Having finished all the adjustments open and close the door to make sure the limit switches work properly Technical documentation 31 4 ie WSS OSD S 62 BY GA V sai 85 86 N Ex 33 34 Assembly and Operating Instructions BR 100 E Roller Door Technical documentation Technical documentation Assembly and Operating Instructions BR 100 E Roller Door 35 WISNIOWSKI r WISNIOWSKI Ltd 33 311 Wielogtowy 153 Poland Tel 18 44 77 270 Fax 18 44 77 277 www wisniowski pl AaOl BR 100E 06 2005
3. Conditions for the installation of BR 100 E door 4 uem IT errors in the position of walls that may cause damage to the door a Technical documentation 9 Assembly and Operating Instructions BR 100 E Roller Door EET F el ao ee 555 A I 2 5 D ge G o gt SS 10 Technical documentation Assembly and Operating Instructions BR 100 E Roller Door Door assembly Tools and fasteners Technical documentation 11 Assembly and Operating Instructions BR 100 E Roller Door 13 400 600 400 600 12 Technical documentation Assembly and Operating Instructions BR 100 E Roller Door Install when all the holes have been drilled Technical documentation 13 Assembly and Operating Instructions BR 100 E Roller Door A side
4. WISNIOWSKI Assembly and Operating Instructions o 0 6 6 6 o BR 100 E Roller Door catalogue No AW 05 53 Technical documentation Last update June 1 2005 Assembly and Operating Instructions BR 100 E Roller Door IMPORTANT INFORMATION Read these instructions and follow them carefully They contain essential information to ensure secure assembly use and proper maintenance of the BR 100 E door Keep this manual in a safe place KEY TO SYMBOLS W1 left side distance W2 right side distance N doorhead So door opening width Ho door opening height 56 door width guide rail length doorframe height servomotor servomotor mounted on the left servomotor mounted on the right black wire Pb brown wire Pn bluewire Pz yellow and green wire photocells A When installing the drive system follow the guidelines provided by the door and drive unit manufacturers and use only original parts delivered by the door manufacturer A 1 DESIGN DESCRIPTION AND TECHNICAL DATA Do not modify or remove any door components This may cause damage to the components that ensure its safe use The door opens up vertically This is why no obstacles should be left within the door s working range Make sure that while the door is in motion there are no people and especially children or objects in its close proximity WISNIOWSKI offers BR 100 E roller doors with standard
5. A F connector 3 15A fuse ee Extra function connectors 12 345 ge se 0 auto closing C N 1 opening only IR sender IR receiver 2 fast manipulation v Technical documentation Assembly and Operating Instructions BR 100 E Roller Door Z E q OOOOOOOO i za OKD 3 ddd If safety bar or photocells are used remove the A F connector from the remote control board Technical documentation Assembly and Operating Instructions BR 100 E Roller Door 52 1 T storing successful storing unsuccessful NS Technical documentation 27 Assembly and Operating Instructions BR 100 E Roller Door 5 gt EN Do not peel off the warranty sticker By removing the warranty sticker you forfeit your warranty rights FPHU WISNIOWSKI Serial number ELDRIM 03 326 WISNIOWSKI WARNING If this sticker is damaged warranty rights are forfeited 28 Technical documentation Assembly and Operating Instructions BR 100 E Roller Door lt on the right top position adjustment screw SS on the right 52 i the left P on the left bottom position adjustment screw 61 51 611 X on the right on the left
6. If remote control or automatic drive system is used photocells are installed as a standard solution to prevent the door from closing should an obstacle appear in it 2 APPLICATION The BR 100 E roller door is a garage door and cannot be used continually The BR 100 E roller doors are designed for private houses but may also be used as shop doors in shops stores offices etc The BR 100 E roller door is designed for installation inside the room These doors cannot be used in common garages and other buildings where they would be frequently used more than 4 opening cycles per hour 3 SAFETY TIPS Carefully read the instructions in this booklet before assembling and operating the door Following the assembly and operating instructions will ensure the doors correct installation and long trouble free use All assembly operations must be carried out in the specified order 4 ASSEMBLY CONDITIONS The door should be used in accordance with its specified application The selection and use of the door should be in accordance with the building s technical documentation made according to the local Building Law and other local standards and regulations The BR 100 E door may only be installed in rooms with another exit The roller doors may be installed in walls made of ferroconcrete bricks or metal or wood framework The room in which it is to be installed should be completely finished walls plastered floor finished The walls cannot s
7. LIMIT SWITCHES TUBULAR SERVOMOTOR Manufacturer s recommendations e electric drive system should be installed in accordance with the installation instructions e When repairing and adjusting the servomotor use only tools that ensure safe detachment and adjustment of the servomotor without causing any damage including the special adjustment screw delivered with the door e Adjust the limit switches by slowly turning the adjustment screws If you turn the screws too fast you may damage the servomotor e Never turn the limit switch adjustment screws when the door isin motion e It is recommended that the adjustment of the limit switches be done using the manual opening buttons When remote control units are used the servomotor 15 activated with some delay after receiving the impulse which makes it difficult to precisely determine the top and the bottom position of the door e Adjust the top limit switch in such a way that when the door is open approximately 100 mm of the door curtain remains in the guide rails 5 5 1 Adjustment of limit switches When adjusting the limit switch of the lower position of the curtain use as the reference point the way the hangers and the top profile are positioned after the door has been completely closed Fig 64 66 A Activate the door to let it close Fig 67 and wait till it closes completely Then press the DOWN manual switch and holding the switch slightly turn the
8. adjustment screw of the lower position of the curtain 51 in the direction Fig 68 until the door starts working If the curtain the top profile and the hangers is still not in the required position when the door has stopped Fig 65 repeat the same procedure until the proper adjustment is achieved A Turn the door on to let it open and then stop it approximately 50 cm above the floor Fig 71 Slightly turn the adjustment screw of the lower position of the curtain S1 in the direction Fig 69 Then turn the door on again to let it close Fig 70 and wait until the curtain closes completely If the curtain the top profile and the hangers is still not in the required position when the door has stopped Fig 65 repeat the same procedure until the proper adjustment is achieved If the limit switch of the lower position of the curtain is set too early Fig 66 in relation to the optimal position do the following If the limit switch of the lower position of the curtain is set late Fig 64 in relation to the optimal position do the following Technical documentation Assembly and Operating Instructions BR 100 E Roller Door When adjusting the limit switch of the upper position of the curtain use as the reference point the position of the bottom profile after the door has been completely open Fig 73 75 A Turn the door on to let it open Fig 72 and wait until the curtain stops T
9. and then reconnect it e checkthe3 1A fuse if burnt changeit e checkthat the power supply is correctly connected e iftheproblem persists contact the authorised service e theLED diode does not react to pressing the UCZ button e disconnect the control unit from the mains insert the A F connector check if the control unit works correctly e thecontrol unit works correctly check that the photocells are correctly connected or change them remove the A F connector e the control unit does not work disconnect the control unit from the mains for about 1 minute and then reconnect it e ifthe problem persists contact the authorised service Failure to follow the above basic recommendations may cause problems when using the door damage to the door or loss of warranty If resistance is felt when moving the door or other defects are noticed check the relevant parts If in any doubt contact the manufacturer s service department 8 CLEANING The following maintenance work may be performed by the user after thorough reading of the assembly and operating instructions delivered with the door e clean the door surface and the protective rings with mild cleaners that are safe for painted surfaces such as clean water and a soft sponge or other commonly available cleaners for painted surfaces e when cleaning the glazed segments do not use any cleaners based on alcohol or solvents as they may cause the acrylic glass to lose l
10. dimensions specified in the pricelist Other doors may be manufactured on request with dimensions within the following range from 2400 x 2000 to 5000 x 2900 mm Fig 2 The BR 100 E roller door is made of AW100 aluminium sections filled with foamed polyurethane which when assembled make up the door s curtain The door slides in side aluminium guide rails with slides and plastic brushes The door curtain is wound onto a reel which is situated between two side lids and is further protected with a cover The door is powered with a 230V 50 Hz AC tubular electric servomotor This servomotor is not designed for continuous work The design of the servomotor allows 40 of effective working time within a period of 10 min This means that the servomotor can work for 4 minutes and must then rest for approximately 6 min Otherwise a thermo switch will be activated and the door will be blocked for several minutes until the servomotor cools down If the thermo switch is activated twice do not activate the door until the servomotor cools down completely after approx 60 min Each drive unit is equipped with an emergency opening system with a crank If the thermo switch has been activated do not open the door with the emergency crank This may damage the servomotor The manual crank should only be used in emergency and cannot be used as the main drive system of the door The drive system may be equipped with remote control units transmitters
11. protect the servomotor from falling down and from moisture Procedures that may be performed by qualified trained and duly authorized technicians e atleast once every twelve months and in the case of industrial doors once every six months inspect the door and e check that all the linking parts are tight and properly fastened especially the screws that hold the guide rails hangers consoles and servomotor e if any errors in the working of the electric drive system noticed disconnect the drive system from the mains for 2 3 minutes and then re connect it e ifanydefects are noticed rectify them immediately e check the hangers if broken change them Procedures that may only be performed WISNIOWSKI s duly authorized technicians e anymodifications of the door e repairs of electric components Technical documentation Assembly and Operating Instructions BR 100 E Roller Door Please note WISNIOWSKI recommends signing a contract for paid warranty and post warranty service procedures performed at least every 6 months When performing any service and repair work strictly follow the recommendations in these Assembly and Operating Instructions especially the hygiene and safety at work regulations 9 SERVICE Concerns only service crew s equipment List of spare parts 50 Nm servomotor AW 77 590 Rotary switch AW 77 501 Key switch AW 77 530 6 7 Eg IET 15 5 1 The manufacturer rese
12. system is shown in Fig 46 49 Electric equipment should only be installed by qualified and duly authorized persons Such persons must be able to evaluate the tasks they have been entrusted with recognize possible risks and use appropriate safety procedures The diagrams in Fig 44 1 44 4 show the connection of the control system to the servomotor mounted on the right side of the door If the servomotor is on the left switch the black and brown wires When using photocells or an optic bar remove the A F connector from the remote control board Fig 51 5 3 eL6Q CONTROL UNIT INSTALLATION Turn off the power e Install the automatic unit e Connect the wires to the eL6Q control unit as follows e manualoperation option e externalaerial option e lightingorsignallight option e infrared barrier e powersupply servomotor lurnonthe power e Cancel the memory and program the remote control unit as shown in the programming Instructions e Activate the automatic unit manually or using the remote control unit The door must start opening If it does not switch the motor wires change the black and the brown wires A 5 4 PROGRAMMING THE eL6Q CONTROL UNIT Remove the A H connector only if an emergency switch is used The connector must be in place in any other case Program the eL6Q control unit using the UCZ button and the LED diode on the control unit board Programming may be done when th
13. 0000000000 key switch 22 Technical documentation Assembly and Operating Instructions BR 100 E Roller Door 44 2 Safety bar and NICE photocells black blue brown yellow and green FRABA wires B brown W white G green Y yellow P gray Auto closing 0000000 ning onl d Ope Fast manipulation Manipulator H stop openning C closing A power supply Aerial IR sender IR receiver key switch 23 Technical documentation Assembly and Operating Instructions BR 100 E Roller Door 44 3 Safety bar and KJ 2000 photocells black blue brown PE yellow and green FRABA wires B brown W white G green Y yellow P gray Auto closing 0000000 ning onl d Ope Fast manipulation Manipulator ooooooooon stop 09 openning closing Sequential power supply b control v Aerial IR sender IR receiver key switch 24 Technical documentation Assembly and Operating Instructions BR 100 E Roller Door 44 4 motor 0 blue brown PE yellow and green L Tj L1 SW SW BL NICE photocells oo IR sender IR receiver 2 3 4 2 AY mm p KJ 2000 photocells Option oo oo oo 09 1111311 ____ 11 e mL a UCZ button LED diode control unit button
14. 350 side 400 a 223 mm 10 mm for side 350 a 273 mm 10 mm for side 400 8 for So 2000 3000 mm for So 3000 4000 mm for So 4000 5000 mm Ox a 5mm 14 Technical documentation Assembly and Operating Instructions BR 100 E Roller Door 22 1 EY Ta 70 M I m fod Technical documentation Assembly and Operating Instructions BR 100 E Roller Door 16 Technical documentation Assembly and Operating Instructions BR 100 E Roller Door p A E mm m Technical documentation 17 Pa LTL Assembly and Operating Instructions BR 100 E Roller Door 4 ge R 42 42 1 rotary switch key switch key switch remote control box
15. OTOR INSTALLED ON THE RIGHT Setting the operating limits 1 Take off the yellow cover to allow access to the setting buttons Fig 80 2 Press both setting buttons all the way down Fig 80 Setting the top limit 3 Turn thedoorontoletitopen Fig 81 4 When the required position is reached release the bottom setting button P2 white by pressing it again Fig 82 5 Thelimit has been set Setting the bottom limit 6 Turn the door on to let it close Fig 83 7 When the required position is reached release the top setting button P1 yellow by pressing it again Fig 84 8 Thelimit has been set 9 Having finished the setting put the yellow cover back on water protection Fig 85 Adjustment of the set limits 10 Increasing the distance between the limits see steps 6 9 11 Decreasing the distance between the limits turn the door on to let it open and stop it before it opens completely 12 Press the button corresponding to the direction you wish to modify P1 or P2 all the way down 13 Repeat the setting procedure following steps 6 9 SERVOMOTOR INSTALLED ON THE LEFT Setting the operating limits If the servomotor is installed on the left it has flat handles attached to the buttons Fig 86 1 Pull both flat handles of the setting buttons all the way out Fig 86 Technical documentation Setting the top limit 2 Turn the door on to let it open Fig 87 3 When the required positi
16. e door is not in motion if the one touch option is activated wait until the door closes completely Assembly and Operating Instructions BR 100 E Roller Door Programming the light deactivation delay time after the servomotor stops To activate the program mode press the UCZ button and hold it for no more than 3 s the LED diode lights up Fig 52 Release the button You have 10 seconds to start the programming procedure You can set the delay time by pushing the same button One push equals 15 seconds i e four pushes 1 min The LED diode fades with each push The maximum light burning time is 40 min The processor automatically remembers the setting when programming is abandoned which is signalled with three blinks of the LED diode and returns to the normal mode A The senders are programmed by the manufacturer If the code of a sender must be changed follow these instructions If the above function is not used do not change the original setting Programming the remote control unit code The eL6Q control box uses remote control units with a dynamically changeable code radio frequency 433 92 MHz and may remember up to 20 remote control units Each remote control unit must be programmed individually Press the UCZ button and hold it until the LED diode lights up and goes off Fig 53 Now you have approximately 10 seconds to press the selected button on the remote control unit When the LED diode blinks th
17. e 1 button until the door opens completely 2 close press and hold the button until the door closes completely 3 The door may bestopped in any position by releasing the button Il Operating the door with remote control under normal conditions no power failure 1 To open press the button on the remote control unit once and wait until the door opens completely 2 To close press the button on the remote control unit once and wait until the door closes completely 3 The door may be stopped in any position by pressing the button on the remote control unit IIl Opening the door in emergency in case of power failure manual operation 1 To open the door in emergency use only the emergency crank that is delivered with the door 2 The manual crank should only be used in emergency and cannot be used as the main drive system of the door 3 When the door is normally used the emergency crank should be detached and kept in a place that is not accessible to unauthorized persons 4 Neverturn the emergency crank if the power supply is connected to the servomotor A 6 1 ADDITIONAL RECOMMENDATIONS If the room has no other exit do not close the door if there are people inside e To open and close the door under normal conditions use only the electric servomotor In emergencies use the emergency crank Assembly and Operating Instructions BR 100 E Roller Door e Install the electric drive system according to
18. h the emergency crank Fig 28 17 Slidethe door curtain into the guide rails Fig 29 18 Detach the emergency crank Fig 30 19 Fasten the door frame to the wall Fig 31 39 20 Puton the curtain cover Fig 40 21 Attach the emergency crank Fig 41 22 Connect the electric drive and control systems following the instructions in 5 2 5 2 CONNECTING ELECTRIC DRIVE AND CONTROL SYSTEMS Safety tips Methods of performing electrical connections and installing electric shock protection systems are specified by the relevant standards and legal regulations The power supply circuit must be equipped with a power cut off device Earthing of the drive system should be made first When installing electric equipment use wires delivered with the door by the manufacturer Equipment A standard BR 100 E door is operated with an up down switch mounted inside the room and a switch with a key mounted outside On request it may be equipped with a remote control system two senders a receiver and photocells Fig 42 45 A 230V socket The mains socket should be situated close to the manual control unit Do not activate two switches that control the door at the same time Control switches cannot work with the one touch function activated Connecting the up down switch The up down switch must be mounted on an inside wall in a place that will allow you to observe the door when operating it The key s
19. hen press the UP manual switch and holding the switch slightly turn the adjustment screw of the upper position of the curtain S2 in the direction Fig 77 until the door starts working If the curtain the bottom profile is still not in the required position when the door has stopped Fig 74 repeat the same procedure until the proper adjustment is achieved A Turn the door on to let it close and then stop it approximately 50 cm below the doorhead Fig 76 Slightly turn the adjustment screw of the upper position of the curtain 52 in the direction Fig 79 Then turn the door on again to let it open Fig 78 and wait until the curtain stops If the curtain the bottom profile is still not in the required position when the door has stopped repeat the same procedure until the proper adjustment is achieved If the limit switch of the upper position of the curtain is set too early Fig 75 in relation to the optimal position do the following If the limit switch of the upper position of the curtain is set late Fig 73 in relation to the optimal position do the following Having finished all the adjustments open and close the door to make sure the limit switches work properly If the curtain is pulled into the reel casing when the door opens completely carefully slide the curtain back into the guide rails using the emergency crank 5 5 2 Adjustment of limit switches SOMFY servomotor SERVOM
20. how signs of any faults or defects Fig 4 6 The room should be dry and free from any chemicals that might damage the door s paintwork A The floor along the bottom seal should be properly levelled and made in such a way as to ensure proper water flow off Ensure proper ventilation drying of the garage Cover the door when renovation work is carried out to protect it against bits of plaster or cement or drops of paint or solvents The correct assembly of the door requires a doorhead that is needed for mounting the door frame The minimum doorhead height is Nmin 250 mm for doors with Ho lt 2 100 mm and 56 max 2800 mm Nmin 300 mm for doors with 2700 and Nmin 350 mm for doors with Hox 2900 mm The side distances W1 and W2 are a minimum of 110 mm Fig 7 When a standard door is open two segments of the door curtain remain in the door opening which reduces the height of the opening by approx 200 mm Fig 8 The door must not be installed in a room whose walls and floor have not dried completely as the condensation that collects on the door surface especially in wintertime may damage it 5 ASSEMBLY The correct performance of the door depends to a large extent on its proper installation When assembling the door strictly follow the instructions below to avoid the door s malfunction its premature wear and a possible loss of warranty A 5 1 ASSEMBLY ORDER When assembling and installi
21. ng the door follow the local health and safety at work regulations concerning assembly and fitting work performed with electric tools in accordance with the assembly technique used and adhere to the applicable standards and regulations and the relevant building documentation 1 Before you start the assembly check and compare the door s dimensions with the door opening s dimensions Fig 11 2 Drillholesin the guide rails Fig 12 Technical documentation Assembly and Operating Instructions BR 100 E Roller Door 3 Attach the brush seals Fig 13 Having drilled the holes clean the rails and brushes of any dust or particles produced by the drilling Fig 13 5 4 Position the guide rails and line them up with the door opening Fig 14 5 Markthe mounting holes on the wall Fig 15 6 Drill the mounting holes in the wall Fig 17 7 Drive plastic plugs for screws into the holes Fig 18 8 Markthe mounting holes on the doorhead Fig 19 9 Drillthe mounting holes in the doorhead Fig 20 10 Drive plastic plugs for screws into the holes Fig 21 11 Remove the curtain cover Fig 22 12 Position the hangers on the shaft align them with the holes and fasten them to the shaft Fig 23 13 Secure the door frame with the door curtain in the guide rails Fig 25 14 Carefully position the door and align it with the door opening Fig 25 27 15 Fasten the guide rails to the wall Fig 27 16 Attac
22. on is reached release the top setting button P1 by pulling the flat handle again Fig 88 4 Thelimit has been set Setting the bottom limit 5 Turn the door on to let it close Fig 89 6 When the required position is reached release the bottom setting button P2 by pulling the flat handle again Fig 90 7 Thelimit has been set Adjustment of the set limits 8 Increasing the distance between the limits seesteps 5 7 9 Decreasing the distance between the limits turn the door on to let it open and stop It before it opens completely 10 Pull the flat handle corresponding to the direction you wish to modify P1 or P2 all the way out 11 Repeatthesetting procedure following steps 5 7 AN 6 GUIDELINES FOR TROUBLE FREE OPERATION Having finished all the adjustments open and close the door to make sure the limit switches work properly Do not block the door or leave any objects in its way Make sure that while the door is in motion there are no people and especially children or objects in its close proximity Do not allow children to play with the door equipment Keep the remote control units out of the reach of children Before you open the gate for the first time check that it has been properly installed The gate has been properly installed when it moves smoothly and its operation is easy Opening and closing l Operating the door under normal conditions no power failure 1 To open press and hold th
23. ree times the programming is finished successfully Fig 54 If you intend to program more remote control units after the LED diode blinks three times you have another 10 seconds to program another remote control unit etc When the LED diode blinks once the programming is finished If 20 remote control units have been programmed earlier the memory is full The LED diode will blink only twice after the programming and will return to the normal mode If you use fewer than 20 remote control units erase the memory and program all the remote control units again Otherwise purchase an eL 3Q module which will increase the number of remote control units by 62 Erasing memory Press the UCZ button and hold it until the LED diode lights up goes off and then blinks Then release the UCZ button Fig 55 The LED diode should blink five times It is recommended to erase the memory if a remote control unit is lost Programming the time after which auto closing function is activated Before programming the time after which auto closing function 5 activated disconnect the control system from the mains and short circuit the connector at the point where it says O Fig 56 Re connect the control system to the mains and program the auto closing function To put the unit in the program mode press the UCZ button and hold it until the LED diode lights up no longer than 3 seconds Fig 57 Then push the UCZ button again to set the required au
24. rves the right to change without notice the design of the product in accordance with new technologies without changing its functionality This documentation is the property of FPHU WISNIOWSKI Any copying and use thereof in part in whole without a written consent of the owner is strictly forbidden Technical documentation Assembly and Operating Instructions BR 100 E Roller Door General information View of BR 100 E door E 24 zum 32 39 28 30 41 Door dimension range ES 20 0006010200 1 K RRR EEE EE K R EE ESERIES CIEE gt BERGER RRS 24_ RE EG C CERES Ei REE 5 0 00 20 SESE 5 22 EES RRs ERR ESE l ELLE R O HENS 3 4 3 5 3 6 3 7 3 8 3 9 4 0 5 4 6 4 7 4 8 4 9 5 0 Door opening width 2 4 2 5 2 6 2 7 28 8 Technical documentation Assembly and Operating Instructions BR 100 E Roller Door BR 100 E door design diagram Es protective ring reel shaft hanger curtain cover door frame fp oy oo m 3 SSS SS d i Em RR 100 section bottom section sealing guide rail
25. the installation instructions e Having installed the door clean the protective rings on the shaft and do not allow them to get excessively dirty while the door 15 normally used e Make sure the door does not get excessively dirty especially protect the door against any substances that might scratch It e g sand When the door is closed do not turn the emergency crank in the closing direction This may cause damage to the door 7 TROUBLE SHOOTING Errors may be made while the door is assembled These can be avoided by making sure that e The door guide rails and the doorframe are correctly installed they must be vertical horizontal and their diagonals must be equal e door surface when closed is flat and even and that the profiles are not deformed e Thelimit switches are correctly adjusted e All the elements fit properly and the screws are tightened Remote control does not work e theindicator light on the remote control unit does not work e changethebattery change the remote control unit e manual control and remote control unit work correctly disconnect the control unit from the mains for about 1 minute and then reconnect it e erase the memory and program the remote control unit again e iftheproblem persists contact the authorised service Manual control does not work e theLED diode does not react to pressing the UCZ button e disconnect the control unit from the mains for about 1 minute
26. to closing time One push equals 15 seconds The LED diode fades each time the UCZ button is pushed Fig 58 With this setting the signal light changes its working mode It burns when the door is open The closing time is determined by the light activation delay time When auto closing is used photocells must be installed for safety reasons The photocells will additionally shorten the time the door is held open The eL6Q will register the time at which a vehicle left the doorway and will close the door after 5 seconds A Opening only function connector 1 To activate the opening only function put the connector on both pins Fig 59 When the connector is used the button on the remote control unit or the manual control button only opens the door This function is useful when auto closing function 15 activated If the above function is not used do not change the Original setting If auto opening function is used light activation time cannot be changed or adjusted Fast manipulation function connector 2 The fast manipulation function is not active when a tubular servomotor Is used This option changes the role of the manipulator You do not have to use the STOP button to change the door s movement direction Door motion signal activation Press the UCZ button and hold it no longer than 3 seconds then wait for approximately 10 seconds until the LED diode blinks three times 5 5 POSITIONING AND ADJUSTING
27. uster Mild cleaners may be used but it is recommended to try their effect on a small area of the glass first at least once every three months and in the case of industrial doors once a month inspect the door and check e all the fasteners that hold the door on the wall screws hangers curtain rollers position of limit switches and if any defects are noticed they have to be rectified immediately Do not use the door until the defects are rectified e that when the door is completely open at least one curtain profile remains in the guide rails If the curtain slides out of the guide rails manually slide it back into the guide rails Never activate the electric drive system if the curtain has slid out of the guide rails e if any defects are noticed they have to be rectified immediately e atleast once every six months lubricate the guide rails with silicon oil e g OILSIL in spray e at least once every twelve months change the batteries in the remote control units e in doors with electric safety devices once a month check that the following devices work properly e photocells simulate the working conditions when the infrared beam is broken the door should stop and open again e loptic bar the door should stop and open again when it touches a 40 mm high object placed on the floor If necessary readjust the bar and check it again as wrong adjustment may cause an accident e during normal use and repairs
28. witch must be mounted on an outside wall of the building also in a place that will allow you to observe the door when operating it This is required for the safety of others The connection diagram is shown in Fig 44 1 Infrared barrier photocells The eL6Q control unit is an electronic device used for controlling the door s operation It must be mounted inside the building in a place that will allow you to use the wires provided in the kit to make all the connections for safety reasons do not lengthen extend the 230V power supply wires Technical documentation From the place the control unit is mounted in you should be able to see the door opening as the unit has a manual operation button Fig 45 This is why another switch should not be installed in the garage The guaranteed working range of the control system in an open space is approximately 30 m The control unit should not be installed close to other electric and metal devices objects The actual working range depends on local conditions buildings and the place of installation If the door is equipped with a remote control system photocells are installed as standard equipment A photocell reacts when the infrared beam is broken and stops the door immediately When the photocells are activated the door stops and then opens completely If an obstacle remains in the doorway the control system is inactive and the door cannot be activated Installation of the remote control
Download Pdf Manuals
Related Search
Related Contents
reglement particulier TDA30XUSERENH_User_Manual_iD-Series 2015-03-13 Teaching English Verbs With Bilingual Corpora - CLILLAC-ARP TÜV International Certification Vitrification du verre - Emotion-24 HSG 1111 - Partnershop INSTRUCTION MANUAL Hogastra CNS 130 Mode d`emploi Hitachi DZ Samsung SCH-E189 Manuel de l'utilisateur Manuel d`installation et d`entretien Electrodistributeurs à trois et cinq Copyright © All rights reserved.