Installation- and Operating Instructions

image

Contents

1. 34 35 36 Operating Instructions Euromatik 2000 Page 28 The following displays are possible Press key OFF The contact in the press key is open Press key ON The contact in the press key is closed Dry running protection This message only appears in case of an operation with overflow collecting receiver This line shows if the electrode of the level control at clamp 44 has water contact The following displays are possible TRS Level OFF The electrode has no water contact TRS Level ON The electrode has water contact Minimum water level This display only appears in case of operation with overflow collecting receiver This line indicates if the electrode of the level control at clamp 45 has water contact The following displays are possible MIN Level OFF The electrode has no water contact MIN Level ON The electrode has water contact Maximum water level This display only appears in case of operation with overflow collecting receiver This line indicates if the electrode of the level control at clamp 46 has water contact The following displays are possible MAX Level OFF The electrode has no water contact MAX Level ON The electrode has water contact Overflow protection This display only appears in case of operation with overflow collecting receiver This line indicates if the electrode of the level control at clamp 47 has water contact The following displays are possible Overflow protection The electrode has no water
2. ssesssesssecssecssecesecesccesccesocesocesocesocesocescossoosscoseooseooesoosssosesosssosssssssoe 10 Application for outdoor swimming pools esssoesessossossoesossessoesocsoesocssesoossesoossoseoesocsoesooseessosseseossosssssossss 10 Notice of function of the level control for receivers sesessesesoesesoesossesesocsossesosoosossesocsosoesecossossesoesosoesesose 11 Swimming pools with skimmer se sseesoeesoocssocsoocssocssoossoosooossoocososcocecosscosecooscooecosscooseooseoseesossosseosesosseosssose 11 Application without level control seseeesocesocesocesocesocesooesocescossooseocecooescosesocesosesosesocesocssoesssesssesssesssesssecssese 12 Magnetic valve water ackfeed sicciscccissscssessssssnsessoossssnasesesesvoctosseesssssssesessosnosesenasesedesdossesensoooecs deocesesesvectesss 12 Temperature Sensor 8 eessiecetiscicarvasutecsiasuadixaaebascen dast so aneis oo insir ainsin ii etes Sia ini eri eseria 12 Feten e OnO AE a E ES 13 Control elements on the front plate esssessssesssessssessseesseessosssoessseesseceseossooessoessseesseossooessoesssessseesseeseo 13 Adjusting Of temperature control lt ceciccassisscvnnsvikecssedescassdssenivss essivensdbsnvandevnavsenshasensvevennsavdbatesedeberenes s 17 I AT AIEE E E E A E 18 Electronic motor POLO CEOS ser eneairsicinsiiiiereiriinorsise soeia isie rsen ED SEE N a EEn S Sa 18 Code Switeheseoseiis rinira de zens D EEEE E E AEE r E NE EEEE aia aerate etr Disate EE eaaa 19
3. Backwash weekly or once a fortnight This line indicates if the backwash is to be carried out every week or once a fortnight Backwash once a fortnight can be switched on with code switch no 3 The following displays are possible Once a fortnight Code switch no 3 is in position OFF The backwash is OFF carried out every week Once a fortnight ON Code switch no 3 is in position ON The backwash is only carried out once a fortnight If this function is activated the backwash timer see above must be set for the operating mode weekly timer On delivery backwash once a fortnight is switched off Selector switch level control This line indicates if the level control has been selected for the receiver or for the skimmer Operating Instructions Euromatik 2000 Page 30 The following displays are possible Level electrodes Code switch no 4 is in position OFF The level control for the receiver has been selected Hanging electrodes must be connected to the connecting clamps 43 to 47 Float switch Code switch no 4 is in position ON The level control for the skimmer has been selected A mini float switch must be connected to the connecting clamps 43 and 44 Attention No dry running protection in this position On delivery the level control for the receiver is switched on The following lines serve the manual control of the output relay 41 42 Filter pump If the operating mode of the filter pump is indicated in
4. 30mA Before opening the housing it is absolutely necessary to switch the device to zero potential Preparation of the six port valve Prior to the installation of the EUROMATIK actuator you have to ensure that the valve runs smoothly and is absolutely free of dirt On installing the actuator the six port valve must be in position Filtering In this position the handle of the valve must be removed by starting the mounting bolts out of the valve axis Subsequently you have to centrally insert the delivered shorter osf bolt into the borehole of the valve axis If the bolt is too loose inserted in the borehole it may be fixed with some glue or grease to facilitate the installation of the actuator For the subsequent functioning of the equipment it is of no importance if the bolt is loose as it will be centered by the housing of the actuator Preparation of the EUROMATIK actuator The actuator must be in position Filtering condition on delivery In order to even out height differences of the valve axis with some valves you have to glue one or more of the delivered self adhesive distance shims under the housing of the control unit The determination of the distance shims is carried out as follows Place six port valve in position Filtering Install actuator without distance shim onto the Insert sis thickness valve See Installation of the control unit gauge Put enclosed thickness gauge between actuator 4 a
5. appears 2 The limiting temperature can be changed with the keys Al and M The lowest setting value is 30 the highest is 50 3 If the key is pressed again the normal diagnostic display appears and the filter system continues to operate The set value is automatically saved On delivery the set limiting temperature is 40 This limiting temperature only has an effect on the solar heating Minimum time of the additional heating This line indicates the minimum duration the additional heating is switched on or off by the temperature control to avoid too short switch intervals This value can be adjusted to the requirements of each corresponding heating equipment if it is displayed in the first line of the service terminal 1 On pressing the key l l the filter system is switched off and the following display appears 2 The minimum time can be changed in steps of 10s with the keys Al and M The lowest setting value is 10s the highest is 1800s 30 minutes 3 If the key J is pressed again the normal diagnostic display appears again and the filter system continues to operate The set value is saved automatically This set time only has an effect on the behaviour of the temperature controller On switching off the filter pump the additional heating is switched off immediately regardless of the set waiting time On delivery the set minimum time is 2 minutes 14 15 Operating Instructions Euromatik 2000 Page 2
6. no connection is carried out it needs to be screwed in The clamps lead mains voltage Instead of the factory provided bridge inserted between clamps 17 and 18 it is possible to connect a flow monitor or a pressure controller to additionally protect the pump against dry running In case of filter operation this contact has to be closed at the latest 10 seconds after starting of the filter pump otherwise the filter pump is switched off and the error message light flashes In the backwash operation this contact is not interrogated The clamps lead mains voltage Mains supply for use of a 230V alternating current pump Euromatik 2000 Pre fuses Protective max B16A winding Fl switch Filter pump 25A 0 03A 230V max 8A Mains 1 N 230V 50Hz So that the electronic motor protection works properly the motor current must be led via all three contact points of the filter control clamps L2 and L3 as well as U1 and V1 bridged pump connected to W1 Operating Instructions Euromatik 2000 Page 7 The factory provided inserted bridge between the clamps 15 and 16 must be removed if a pump with protective winding contact is connected If no connection is carried out it needs to be screwed in The clamps lead mains voltage Instead of the factory provided bridge inserted between clamps 17 and 18 it is possible to connect a flow monitor or a pressure controller to additionally protect the pump against dry running I
7. on or off 1 On pressing the key J the filter system is switched off and the following display appears Error message OFF Manual operation 2 With the key Al the collective error message can be switched on and with the key V it can be switched off again 3 If the key is pressed again the normal diagnostic display appears and the filter system continues to operate 46 47 48 49 Operating Instructions Euromatik 2000 Page 32 Additional output If the operating mode of the additional output is displayed in the first line of the service terminal it can be manually switched on or off 1 After pressing the key the filter system is switched off and the following display appears Addit output OFF Output can be switched manually 2 With the key A the additional heating can be switched on and with the key M it can be switched off again 3 If the key is pressed again the normal diagnostic display appears and the filter system continues to operate Magnetic valve If the operating mode of the magnetic valve is displayed in the first line of the service terminal it can be manually switched on or off 1 After pressing the key the filter system is switched off and the following display appears Magnetic valve OFF Output can be switched manually 2 With the key A the magnetic valve can be switched on and with the key M it can be switched off again 3 If the key l is pressed again the normal diag
8. seconds the backwash process starts The clamps supply 24V Pressure switch Level control The integrated level control is suited for both swimming pools with flow off gutter and skimmer pools On putting into operation of the control you have to choose the requested option On the board of the control unit there is a code switch where you can set the corresponding operating mode On delivery switch 4 of the code switch is in switch position receiver control By switching to position on the operating mode skimmer pool is switched on Please find a sketch below in the text on page 19 Operating Instructions Euromatik 2000 Page 10 Swimming pools with flow off gutter dipped electrodes are to be used as Euromatik 2000 sensors The tensile stress of the line is sufficient to hang the electrodes into the flow off collecting receiver by means of the special line whereas the individual electrodes may contact each other The fixing is carried out above the receiver by using the electrode holding device The Forced switchingon special lines are brought together in a max customer provided and installed branch box TRS A line e g NYM 0 5x1 5 mm is layed from this branch box to the control unit Mass On connecting the dipped electrodes you have to take particular care that the order is not mixed up since a mixing up of the electrodes will inevitably cause a malfunction of the equipment Applicat
9. sensor must on no account display higher values than 10 11 Operating Instructions Euromatik 2000 Page 22 the water temperature sensor as in this case the solar heating does not switch off Nominal temperature This line displays the nominal temperature that has been set with the key in the front lid If the temperature has been switched off no heating is displayed Motor current This line indicates the current power consumption of the filter pump in the three phases of the three phase network Motor protection This line indicates the set release current of the electronic motor protection Solar difference This line indicates the amount the solar collector has to be warmer than the pool water before the solar heating is switched on Collector temperature Solar _ Water temperature Solar heating off Solar heat on Solar heating off Solar h on This value can be adjusted to the requirements of each corresponding solar equipment if it is displayed in the first line of the service terminal 1 On pressing the key the filter system is switched off and the following display appears Solar diff 3 f Temperature differ between water and collector 2 The temperature difference can be changed with the keys Al and V The lowest setting value is 0 5 the highest is 10 3 If the key is pressed again the normal diagnostic display appears and the operation
10. set with the keys A and V 7 Additional switch times can now be programmed as described in the points 2 to 5 You can enter a maximum of 14 start times To save the times press the EJ key again If on setting no key is pressed for more than 10 seconds the last displayed time is automatically saved and the normal operation display appears again Deleting backwash times If start times have already been programmed these can be deleted with the key 63 1 Press amp J key as long as the display indicates the start time that is to be deleted 1 Rinsing 20 00 2 Set the switch time with the keys Aland YY 1 Rinsing between 23 59 and 0 00 If operated as a weekly timer between 23 59 on Saturday and 00 00 on Monday 3 To delete the switch time press the Ed key again With this key the six port valve can be run into position draining To switch this operating mode the key must be pressed for at least 10 seconds To switch off the operating mode it is sufficient to press the key for a short time Adjusting of temperature control The electronic temperature control and the temperature sensor have been matched factory provided If one of the sensors is exchanged or if a sensor cable is lengthened you have to carry out a new adjustment with the potentiometers in the control unit if necessary A clockwise turning of the potentiometer causes an increase of the displayed water temperature If the p
11. 0 are potential free and can be used for error messages The terminal clamps for the protective winding contact allow to connect a protective winding contact switch that is integrated in the motor winding of the filter pump If this contact opens e g due to overheating of the motor winding both the filter pump as well as the heating and the dosing equipment are also automatically switched off As soon as the protective winding contact closes after cooling of the motor winding the aggregates are switched on again automatically A manual reset is not necessary The terminal clamps for the protective winding contact are charged with 230V Terminal clamps for a remote switch offer the possibility to remote control the filter system The 24 V actuator is connected to the control unit by a 6 core line Backwashing can be done alternatively by 6 way valve or by bar valves The operation of the filter pump and the heating is indicated by pilot lights in the front lid so a check is possible at any time The filter pump is protected against overload by an electronic motor protection current range continuously adjustable up to 8A Operating Instructions Euromatik 2000 Page 4 Installation The control unit has to be installed humidity protected depending on its protection type The power supply of the device has to be effected by an all pole main switch having a contact opening of at least 3mm and an earth leakage circuit breaker with Irpn lt
12. 4 Minimum time of solar heating This line indicates the minimum duration the solar heating is switched on or off by the temperature control to avoid too short switch intervals This value can be adjusted to the requirements of each corresponding solar equipment if it is displayed in the first line of the service terminal 1 On pressing the key J the filter system is switched off and the following display appears 2 The minimum time can be changed in steps of 10s with the keys A and M The lowest setting value is 10s the highest is 1800s 30 minutes 3 If the key lis pressed again the normal diagnostic display appears and the filter system continues to operate The set value is saved automatically This set time only has an effect on the behaviour of the temperature controller On switching off the filter pump the heating is immediately switched off regardless the set waiting time On delivery the set minimum time is 2 minutes Priority circuit of the solar heating This line indicates if the solar heating is priority switched with respect to the setting of the filter periods In case of priority circuit the filter pump can also be switched on by the temperature control outside the set filter periods If not priority switched the temperature control only operates during the filter operation 16 The following displays are possible Priority Solar OFF The solar heating only operates during the filter periods Priority S
13. Daily or weekly timer filtering sessssccoscooecooesooecooecooeccocesoecsocesoocscocsoocssocsooesssossoossoocososcosssssscoseessesosssosees 19 Daily or weekly timer backwash sssssssscsoscooecoosooesooeeooeesosesoeesoecsoocsooesoocsooocsoocssosooocosoccoosesoscoseessscosesssees 19 Backwash weekly or once a fortnight esssessooesooesoossoccsocesocossecssesssecssecesesesecesecesecssocssocesocesocesocesocesocssooses 19 Skimmer or overflow CULL sicssccccesssscercesesensesenscsosessntesssnsicsacesssapsesonseseensosencesonses sGesesecesonsedesesesdonesessessseseses 19 Service terminali scccsesccsccsesvcecesesscescdesesescseseceocaesecesedesscshcsesbdesesessececesaticevses scecdsas ccecdevecccesasdcsesdusececs co s 20 Operating Instructions Euromatik 2000 Page 3 The control Euromatik 2000 enables a time dependent switching on and off of a 400V three phase current filter pump or a 230V alternating current filter pump by using a freely programmable daily or weekly programme The backwash may be carried out manually time dependent or pressure dependent The integrated level control is suited for swimming pools with overflow gutter receiver and for skimmer pools The filter control can be remote controlled by an external control element During the run time of the filter pump the heating of the pool is controlled by the electronic temperature control During the filter pauses the heating is automatically switched off by the i
14. Installation and Operating Instructions EUR MATIK 2000 i Filter and backwash control With connections for bar valves Item no 3105500200 oA DeF EUR MANR Dimensions 325mm x 280mm x 160mm Operating voltage 400V 50Hz Power consumption of control system Approx 15VA Breaking capacity Pump Heating Dosing equipment Useable six port valves Praher 11 2 and 2 Speck 11 2 and 2 Midas 11 2 and 2 Hayward 112 Astral 11 2 With applicable adapter Astral 2 Static water pressure max 0 3bar Water column above valve max 3 0m Operating Instructions Euromatik 2000 Page 2 Table of Contents VIKALI REEE EEE E T E EE S 3 Tistallation in stasis css asesleosaa yas oodecuse colevieaeidseags wide sass dotansecddenssiadeaudbdacadeccunncssuadvanay EESC E SE ASES E e SERES TE SN EESE 4 Preparation of the six port ValVe sicssscscsesossnossossesssecssscassoassecdopediecesennescsesesconctonsesadebesseseseveas sons sscrsceeseoseseseseese 4 Preparation of the EUROMAT IK actuator ccssccsssscsssscssssscssssscsssssssescsssssssssssssessessesssscsssssssessasssssascnes 4 Installation on an Astral 2 Vale ccsccsscscssesssssccsccnsccscescssessscsscsssseseesessssenessessssesecsecssessssncssesssseneesoeees 5 Installation on Astral Midas and Hayward valves sssccssssscsssscssscesssssscsssssccsssssssssecsssscscssssssessssssseees 5 Installation OF the ACLU ALONE istics caeianedidyucces
15. Instructions Euromatik 2000 Page 16 Programming With this key the built in timer is programmed whereas the timer switch on time and the corresponding switch off time always have to be entered in pairs 1 Press key the display indicates 1 Pume ON If the timer is operated as a weekly timer the corresponding day of the week is also displayed Switching over from daily to weekly timer see further below in the text on page 19 2 With the keys Al and M the requested switch on time can be set 3 Press key again the display indicates 1 Pump OFF 0 00 4 Now the requested switch off time can be set with the keys Al and M 5 Press key again the display indicates 2 PumpON 6 Additional switch times can now be programmed as described in points 2 to 5 7 To save the times press the amp key again If on setting no key is pressed for more than 10 seconds the last displayed time is automatically saved and the normal operation display appears again Deleting switch times If switch times have already been programmed they can be deleted with the key 1 Press as long as the display indicates the switch time that is to be deleted gt Pump ON 6 25 2 With the keys Al and set the switch on time 2 Pump ON between 23 59 and 0 00 3 To delete the switch time press the again the corresponding switch off time is also automatically deleted Adjusting W
16. The connector plug for this is placed on the circuit board inside the device Before opening the housing and prior to plugging on and off the service terminal it is absolutely necessary to switch the control to zero potential After the control unit has been switched on the display of the service terminal indicates the first 4 lines of the diagnostic text e g Operating mode of the filter system Operating mode of the heating measured water temperature measured collector temperature Filter operation Temp reached Water Solar 23 0 38 4 Additional lines can be interrogated with the keys A and M Where required the values in the first line may be changed after the key has been pressed 1 Operating mode of the filter system This line indicates the current operating mode of the filter system Following displays are possible Control system off Filter system off Filter operation After run time Forced switching on Priority switching Lack of water Pump locked Motor protection The control system has been manually switched off with the key B The filter system is switched off The filter system has been switched off by the timer the manual switch in the front lid or by the remote switch The filter pump continues to run after the heating has been switched off The filter pump has been switched on by the level control because the water level in the receiver has risen The filter pump has be
17. ater causes an increase of the water level As soon as the rising water level has reached the position of the dipped electrode magnetic valve OFF clamp 46 and has contacted the relevant electrode the magnetic valve closes the supply of fresh water Dry running protection of the filter pump If due to loss of water in the receiver e g caused by backwashing the water level falls below the dipped electrode dry running protection pump OFF clamp 44 the level control switches off the filter pump so that it is not damaged by lack of water As soon as the water level has risen up to the height of the electrode dry running protection pump ON clamp 45 and has contacted said electrode the level control automatically switches on the filter control again Forced switching on If due to water displacement in the swimming pool the water level in the receiver rises and contacts the dipped electrode forced switching ON clamp 47 the level control automatically switches on the filter pump Now the water is pumped back into the swimming pool thus avoiding unnecessary loss of valuable water The dipped electrode forced switching ON is to be placed some centimeters below the overflow Swimming pools with skimmer Euromatik 2000 A mini float switch is to be used as sensor The line of the float switch can be lengthened to up to 100m with a line 2x0 75mm Please note that it is absolutely necessary to carry out connection
18. contact OFF Overflow protection The electrode has water contact ON Float switch This display only appears in case of operation with skimmer This line indicates if the mini float switch is switched 37 38 39 40 Operating Instructions Euromatik 2000 Page 29 The following displays are possible Float switch OFF The float switch has switched off Float switch ON The float switch has switched on Operating mode of the filter timer This line indicates if the built in timer for the filter periods operates as a daily or weekly timer The operating mode of the timer can be changed with code switch no 1 The following displays are possible Filtering daily The programmed switch times are the same for each program day Filtering weekly Different switch times can be programmed for every day program of the week On delivery the timer works as a daily timer Operating mode of the backwash timer This line indicates if the built in timer for the backwash periods works as a daily or weekly timer The operating mode of the timer can be changed with code switch no 2 The following displays are possible Backwash daily The programmed backwash periods are the same for program each day Backwash weekly Different backwash times can be programmed for every program day of the week If backwash is activated once a fortnight this timer must be set as a weekly timer On delivery the backwash timer works as a daily timer
19. djusted to the requirements of each equipment if it is displayed in the first line of the service terminal 1 On pressing the key the filter system is switched off and the following display appears 2 The priority circuit can be switched on or off with the keys Aland M 3 If the key is pressed again the normal diagnostic display appears and the filter system continues to operate The set value is saved automatically On delivery the priority circuit of the additional heating is switched off Time delay of the magnetic valve This display only appears if skimmer operated This line indicates the set time delay for the magnetic valve fresh water supply only for skimmer pools to avoid too short switching intervals This value can be adjusted to each corresponding equipment if it is displayed in the first line of the service terminal 4 On pressing the key l the filter system is switched off and the following display appears Min valve 10s Response delay of magnetic valve 5 With the keys A and V the minimum time can be changed in steps of 1s The lowest setting value is Os the highest 30s 6 If the key lis pressed again the normal diagnostic display appears and the filter system continues to operate The set value is saved automatically After run time of the filter pump In this line it is indicated how long the filter pump continues to run after the additional heating has been switched off This value can be ad
20. ect a 230V bar valve for rinseing Both valves are controlled by the backwash program During backwashing the backwash pump terminals 21 and 22 is also switched on Heating and dosing are switched off during the backwash cycle The backwash and rinse process can be achieved alternatively by bar valves or by the osf actuator for 6 way valves Rinseing If bar valves are used instead of the osf actuator the terminals 31 32 33 34 and 35 have to be wired together short circuited Connection of the backwash pump Ave A backwash pump or a blower may be connected to the clamps Euromatik 2000 21 and 22 The ptential free contact between the clamps is closed during the backwash process The contact can be charged with 230V 4A If pumps with a higher power consumption are used you have to insert an additional Backwash pump switch box item no 3002400000 potential free max 4A Connection of a backwash motor valve two port Euromatik 2000 If on backwashing the water supply in the receiver is not sufficient it is possible to take the required amount of water out of the swimming pool A two port motor valve can be connected to the clamps U7 and U8 that is connected to the floor drain During the backwashing and rinsing process this valve is open Motor valve otherwise it is closed The contact can be charged with 230V backwashing 1A Clamp U7 opened clamp U8 gt closed 230V max 1A Operating Instructions E
21. ed for the water supply This is connected to clamp U9 at the control unit A damped closing magnetic valve R 2 is available with item number 1090005804 from the product range Temperature sensor Euromatik 2000 Nti Immersion sleeve R 172 Solar sensor Temperature sensor pool The pool temperature sensor is connected to the clamps 39 and 40 As a standard the temperature sensor is delivered with a cable length of 1 5m If required it can be lengthened with a two core cable cross section min 0 5mm up to a maximum of 20m It Operating Instructions Euromatik 2000 Page 13 should be avoided to lay the sensor cable near power lines to exclude possible disturbance As an exact temperature control is only carried out with a good heat transfer between the temperature sensor and the pool water an immersion sleeve R 1 2 item no 3200200003 is to be installed into the piping system Any polarity of the sensor is possible A solar temperature sensor item no 3100000030 may additionally be connected to the clamps 41 and 42 As a standard the temperature sensor is delivered with a cable length of 20m If required it may be lengthened with a two core cable cross section min 0 5mm up to a maximum of 50m It should be avoided to lay the sensor cable near power lines to exclude possible disturbance The solar temperature sensor is to be installed at the output of the solar collector and must have a good thermal c
22. en switched on off the set filter periods by the temperature control because the filter pump operates priority switched The filter pump has been switched off due to insufficient water in the receiver The filter pump has been temporarily switched off by the remote switch or the protective winding contact The filter pump has been switched off because the electronic motor protection has triggered Operating Instructions Euromatik 2000 Page 21 Press key The filter pump has been switched off because a press key connected to the clamps 17 and 18 or a flow monitor has not started on time after the filter pump has been switched on Net phase missing _ The filter pump has been switched off because there is no current in all 3 net phases Backwashing The filter is currently being backwashed Rinsing again The filter is currently being rinsed again rinsing clear Draining The actuator is in position Draining Actuator turning The valve position is currently being adjusted at the 6 port valve Operating mode of the heating This line indicates the current operating mode of the temperature control Following displays are possible No heating The heating has been switched off with the adjusting keys in the front lid Heating off Off the filter periods the heating is switched off Heating locked The heating is locked because the filter pump has been switched off due to an error condition or because the 6 port valve is not in positio
23. in the normal diagnostic display appears and the filter system continues to operate Heating If the operating mode of the heating is displayed in the first line of the service terminal it can be manually switched on or off 1 On pressing the key l l the filter system is switched off and the following display appears 2 With the key A the additional heating can be switched on and with they key V it can be switched off again The filter pump is also automatically switched on Attention In this operating mode the electronic motor protection is out of operation 3 If the key lis pressed again the normal diagnostic display appears and the filter system continues to operate Dosing equipment If the operating mode of the dosing equipment is indicated in the first line of the service terminal it can be manually switched on or off 1 On pressing the key J the filter system is switched off and the following display appears 2 With the key A the dosing equipment can be switched on and with the key M it can be switched off again The filter pump is also automatically switched on Attention In this operating mode the electronic motor protection is out of operation 3 If the key is pressed again the normal diagnostic display appears and the filter system continues to operate Error message If the operating mode of the collective error message is indicated in the first line of the service terminal it can be manually switched
24. ion for outdoor swimming pools According to the designed concept of the swimming pool it may occur that in outdoor swimming pools rainwater can raise the water level thus activating the function forced switching on If this operation is not requested the electrode forced switching ON clamp 47 can be disconnected All remaining dipped electrodes are necessary for the function of the control and cannot be dropped and must not be bridged respectively Fonction of the particular dipped electrodes In normal operation the water level is between the electrodes magnetic valve CLOSED and magnetic valve OPEN Forced switching on ON Forced switching OFF Magnetic valve CLOSED Double fonction Magnetic valve OPEN Dry running protection Pump ON The differences in level depend on individual circumstances In order to get sufficient switch intervals you have to ensure 5 cm at a minimum Double fonction Dry running protection Pump OFF Mass Operating Instructions Euromatik 2000 Page 11 Notice of function of the level control for receivers The level control for receivers has the following functions a Control of the water level If due to loss of water in the swimming pool e g caused by evaporation or backwashing the water level falls below the dipped electrode magnetic valve OFF clamp 45 the magnetic valve clamp U9 opens and the flooding fresh w
25. itched on contact closed Flow monitor This line indicates the switch mode of the press key connected to the clamps 17 and 18 or the flow monitor The following displays are possible Flow OFF The contact in the flow monitor is open pump does not deliver Flow ON The contact in the flow monitor is closed pump delivers Locking This line indicates if the filter system has been switched off by the protective winding contact or by a remote switch connected to the clamps 9 and 10 The following displays are possible Locking OFF The pump is switched off one of the contacts is open Locking ON The operation of the pump is released both locking contacts are closed Six port valve This line indicates if or if not the sex port valve has reached any end position With reached valve position and lowered valve disk the display valve position ON appears If the valve disk is not properly lowered the display valve position OFF appears Even in case that the electric connection between the control and actuator is not active the message valve position OFF appears The following displays are possible Valve position ON The operation of the pump is released the valve has reached the end position Valve position OFF The pump is locked the valve has not reached the end position Press key for backwash This line indicates if the press key that can be connected to the clamps 37 and 38 has been switched on or off 32 33
26. ith these keys you can program the water temperature time keys switch and backwash time _ Backwash manual With this key the backwash process is started manually If a Ei backwash time of 0 seconds has been set the backwash process does not start If a clear rinsing time of 0 seconds has been preset the valve position rinsing clear is not run Setting backwash With this key the backwash and rinse time is programmed EJ ume 1 Press key the display indicates 890 Backwashing 2 Now the requested backwash time can be set with the keys A and V 3 Press t key again gt the display indicates 2 Clear rinsing 7 Draining Adjusting sensor N CG east Water AN EOR sl ir Solar Operating Instructions Euromatik 2000 Page 17 4 Now the requested rinsing time can be set with the keys A and V If a clear rinsing time of 0 seconds has been set the valve position rinsing clear is not run If now no key is pressed for 10 seconds the last displayed switch time is automatically saved and the normal operation display appears again 5 Press key again the display indicates 1 Rinsing 20 00 If the timer is operated as a weekly timer the corresponding day of the week is also displayed Switching over from daily to weekly timer see further below in the text on page 19 6 Now the requested start time for the backwash can be
27. justed to the corresponding filter system if it is displayed in the first line of the service terminal 1 On pressing the key the filter system is switched off and the following display appears After run 10s After run time of the filter pump after additonal heating 2 The start time can be changed with the keys A and M The lowest setting value is Os the highest 1800s 19 20 21 22 23 24 25 26 Operating Instructions Euromatik 2000 Page 26 3 If the key lis pressed again the normal diagnostic display appears and the filter system continues to operate The set value is saved automatically On delivery the after run time of the filter pump is switched off after run time 0 Start time of the filter pump This line indicates the maximum allowed time of the filter pump from switching on until reaching the normal flow rate If the contact of a flow monitor connected to the clamps 17 and 18 is not closed within this time after switching on the filter pump is switched off again and the error message light flashes This value can be adjusted to the requirements of the corresponding filter system if it is displayed in the first line of the service terminal 1 On pressing the key the filter system is switched off and the following display appears 2 The start time can be changed with the keys Al and V The lowest setting value is 5s the highest 20s 3 If the key is pressed again the
28. n filtering Temperature The heating is switched off because the set nominal reached temperature has been reached Heating on The heating is switched on because the water temperature is below the set nominal temperature Solar heating on The solar heating is switched on because the water temperature is below the set nominal temperature and because the collector is warmer than the pool water Water temperature This line indicates the current water temperature If the display does not match the actual temperature it can be readjusted with the adjusting controller on the circuit board see section temperature control A clockwise turning of the adjusting controller causes an increase of the displayed value In case of defect temperature sensor break of sensor is displayed Attention If both temperature sensors are at the same temperature the solar sensor must on no account display higher values than the water temperature sensor as in this case the solar heating does not switch off Solar temperature This line indicates the current collector temperature If the display does not match the actual temperature it can be readjusted with the adjusting control on the circuit board see section temperature control A clockwise turning of the adjusting controller causes an increase of the displayed value In case of a defect temperature sensor is displayed Attention If both temperature sensors are at the same temperature the solar
29. n the filter operation this contact must be closed at the latest 10 seconds after the filter pump has started otherwise the filter pump is switched off and the error message light flashes This contact is not interrogated in the backwash operation The clamps lead mains voltage Connection of the heating Euromatik 2000 Heating Potential free Heating 230V max 400W actuator 230V 1A For the operation of the solar heating it is possible to connect a 230V solar actuator to the clamps U5 and U6 When solar operated clamp U6 leads mains voltage and clamp U5 is voltage free If the solar heating is not operated clamp U6 is voltage free and clamp U5 leads mains voltage Connection of the EUROMATIK actuator for the six port distributing valve Euromatik 2000 DEELEN For the connection of the actuator the enclosed six pole connecting line with plug is to be used If connected to the control unit the poles must not be exchanged ellow white brow grey nk blue Operation of the control system without EUROMATIK actuator If the control is to be operated without actuator the connecting terminals 31 32 33 34 und 35 are to be connected bridged The connecting line is disconnected before Operating Instructions Euromatik 2000 Page 8 Connectionof bar valves for backwashing Terminals U10 and N can be used to connect a EUROMATIK 2000 230V bar valve for backwashing Terminal U11 and N can be used to conn
30. nd valve The distance is optimal if the thickness gauge fits exactly between actuator and valve If the actuator is loose on the valve one or more distance shims are to be glued under the actuator see sketch below Afterwards the actuator is to be installed again and you have to repeat the thickness gauge test After the installation has been carried out you have to remove the thickness gauge The arising following looseness will not negatively influence the function of the equipment Operating Instructions Euromatik 2000 Page 5 Installation on an Astral 2 valve For the installation on an Astral 2 valve a special adapter must be used This adapter is put in such a way onto the valve that 1 the screws are inserted downwards and grip into the recesses of the valve 2 both side recesses point to the letterings Filtering and Draining These adapters are available with item number 1200299200 at Installation on Astral Midas and Hayward valves If necessary exchange slides As the guide grooves in the valve lid are smaller with the valves of Midas Astral and Hayward the two yellow slides on the lower surface of the control unit must be replaced by the delivered red slides if the above mentioned valve types are used if necessary glue distance shim Installation of the actuator Simultaneously press both slides totally inward Cautiously put the actuator onto the valve so that the cou
31. normal diagnostic display appears again and the filter system continues to operate The set value is saved automatically This time only has an effect in normal filter operation the press key is not interrogated on backwashing On delivery the set starting time is 10s Operating time of pump This line shows the total number of operating hours of the filter pump Operating time of heating This line shows the total number of operating hours of the additional heating Solar operating time This line shows the total number of operating hours of the solar heating Motor protection counter This line shows how often the electronic motor protection has triggered Press key counter This line shows how often the flow monitor connected to the clamps 17 and 18 or the press key has triggered Phase failure counter This line shows how often the pump has been switched off due to net phase failure Backwash counter This line shows how often a backwash process has been run Operating Instructions Euromatik 2000 Page 27 The following lines enable the service technician to check the input signals and the output relays of the filter control 27 28 29 30 31 Remote switch This line shows if the filter control has been switched on by the remote switch connected to the clamps 7 and 8 The following displays are possible Remote switch OFF The remote switch is switched off contact open Remote switch ON The remote switch is sw
32. nostic display appears and the filter system continues to operate Backwash pump If the operating mode of the backwash pump is displayed in the first line of the service terminal it can be manually switched on or off 1 After pressing the key l the filter system is switched off and the following display appears Backwash p OFF Output can be switched manually 2 With the key A the backwash pump can be switched on and with the key Vit can be switched off again 3 If the key is pressed again the normal diagnostic display appears and the filter system continues to operate Backwash valve two port ball valve If the operating mode of the backwash valve is displayed in the first line of the service terminal it can be manually switched on or off 1 After pressing the key the filter system is switched off and the following display appears Backwash v OFF Output can be switched manually 50 Operating Instructions Euromatik 2000 Page 33 With the key Al the backwash valve can be switched on and with the key M it can be switched off again If the key is pressed again the normal diagnostic display appears and Actuator backwash six port valve If the operating mode of the actuator is indicated in the first line of the service terminal it can be manually operated the filter system continues to operate After pressing the key the filter system is switched off and the following display appears Act
33. ns in the direction of draining Draining The actuator is in valve position draining Control ON OFF Manual operation Acknowledge error message With this key the entire control unit can be witched on and off Attention By pressing this key the control unit is not switched to zero potential If the control unit is switched on this key flashes With this key the filter pump can be switched on manually regardless of the timer The key flashes in case of manual operation If the control detects an error e g motor protection this key flashes in red This error message must be acknowledged by pressing this key so that the normal operation of the Additional ON OFF E el Pilot light heating YI yar PL PN Select temperature as Setting time output Pilot light pump Pilot light heating solar Operating Instructions Euromatik 2000 Page 15 equipment can be continued With this key an additional output clamp U4 230V is controlled that can for instance be used to switch an underwater floodlight The key flashes if the consumer is switched on The function of the additional output is not interlocked with the filter pump This pilot light indicates the operation of the filter pump This pilot light flashes if the heating additional heating is switched on This pilot light flashes if the solar heating is operating With this key the temperature of the po
34. nternal locking Due to the given possibility to connect a safety temperature limiter or a flow monitor the heating is additionally protected against overheating On the front plate the requested temperature of the pool water can be selected or the heating can be switched off For the connection of the heating both a living contact clamp U2 and a floating contact clamps 23 24 are available For the solar collector operation there are terminal clamps available to be used for a solar actuator Terminal clamps for level sensors enable a comfortable automatic control of the water level in the swimming pool Additional terminal clamps allow to connect a flow monitor or a press key Thus the filter pump is addtionally protected against damages that could be caused if the filter system was operated without water Additional terminal clamps allow to connect accessory devices such as e g underwater floodlights and dosing equipment A consumer 230V max 3A connected to clamp U4 may be switched on and off at will with a key placed in the front lid The clamp U3 only leads 230V during the filter periods off the filter periods it is floating The clamps 25 26 are floating and thus may be used individually During the filter periods the relay contact between clamp 25 and 26 is closed off the filter period this relay contact is open This contact can be charged with a maximum voltage of up to 230V and a maximum force of up to 400W cos o 1 Clamps 19 2
35. of the filter system continues to operate The set value is saved automatically On delivery the set temperature difference is 3 Solar additional temperature This line indicates the amount that may be exceeded by the set nominal temperature of the pool water if operated by solar heating so that the insolation can be optimally used during the day This value can be adjusted to the requirements of each corresponding pool equipment if it is displayed in the first line of the service terminal 12 13 Operating Instructions Euromatik 2000 Page 23 1 On pressing the key the filter system is switched off and the following display appears Add solar heat 5 0 9 Water overheating with solar operation 2 With they keys Al and M the temperature difference can be changed The lowest setting value is 0 the highest is 15 3 If the key is pressed again the normal diagnostic display appears again and the filter system continues to operate The set value is saved automatically On delivery the set temperature difference is 5 Limiting temperature This line indicates the maximum temperature where the solar heating is automatically switched off for safety reasons regardless of the set value This value can be adjusted to the requirements of each corresponding pool equipment if it is displayed in the first line of the service terminal 1 On pressing the key the filter system is switched off and the following display
36. ol water is selected 1 Press Z key the display indicates 29 4 Nominal temp 2 With the keys Al and V the requested temperature within the range of 0 1 C up to 40 C can now be set 3 If the heating is to be completely switched off you have to reduce the temperature with the key V as long as the 4 To save the requested temperature press the key again If on setting the temperature no key is pressed for more than 10 seconds the last selected temperature is automatically saved and the normal operation display appears again If a solar sensor is connected to the control the current temperature of the solar sensor can be displayed with this key 1 Press Z key twice the display indicates the temperature at the solar sensor e g 328 Solar sensor 2 To close this display press the key z again If no key is pressed for more than a minute the normal operation display automatically appears again With this key the current time is set 1 Press key the display indicates Time ae if the timer is operated as a weekly timer the corresponding day of the week is additionally displayed 2 Now you can set the current time by using the keys Al and v 3 To save the time press the key amp again If on setting no key is pressed for more than 10 seconds the last displayed time is automatically saved and the normal operation display appears again Operating
37. olar ON The solar heating also operates off the filter periods In case of insolation the filter pump and the solar heating are automatically switched on The priority circuit can be adjusted to the requirements of each equipment if it is displayed in the first line of the service terminal 1 On pressing the key l the filter system is switched off and the following display appears 2 The priority circuit can be switched on or off with the keys A and M 3 By pressing the key again the normal diagnostic display appears and the filter system continues to operate The set value is saved automatically On delivery the priority circuit of the solar heating is set Priority circuit of the additional heating This line indicates if the additional heating has a priority over the setting of the filter periods In case of priority circuit the filter pump can also be switched on by the temperature control off the set filter periods Without priority the temperature control only operates during the filter periods 17 18 Operating Instructions Euromatik 2000 Page 25 The following displays are possible Priority heating OFF The additional heating only operates during the filter periods Priority heating ON The additional heating also operates off the filter periods If the temperature falls below the nominal temperature the filter pump and the additional heating are switched on automatically The priority circuit can be a
38. ontact to the back flowing water External control panel Ve An external control panel can be connected in wall Euromatik 2000 item no 3100000420 or on wall item no 3100000410 to the clamps 48 51 A four core telephone cable item no 3100000500 with a length of max 50m is used for the connection to the backwash control It should be avoided to lay the connecting cable near power lines to exclude possible disturbance External control panel LCD Display Pilot light heating Pilot light solarheating ON OFF Pilot light filterpump manual automatic Adjusting key increase value Reset g Adjusting key decrease value Additional output ON OFF Drain pool Select temparature Program backwash time Program timer Manual backwash Set timer Control elements on the front plate LCD 23 47 14 461 Normal operation display with current water temperature and time LCD 234 After run The filter pump continues to run for a short time after the heating has been switched off LCD LCD LCD LCD LCD LCD LCD LCD LCD LCD LCD LCD m CD LCD 5 7 Gs Operating Instructions Euromatik 2000 Page 14 Forced swit on 13 37 The filter pump has been switched on by the integrated level control Lack of water 13 59 The filter pump has been switched off by the integrated level control Level sensor defect The level senso
39. otentiometer for the solar sensor is turned clockwise a higher collector Operating Instructions Euromatik 2000 Page 18 temperature is displayed As the solar temperature control only works properly with precisely matched sensors this adjustment should only be carried out by a trained service technician Fuses Motorschutz Fe NO PE a aN ae TAN ye pA J j Kot Key PEP T Sod 37 38 39 40 41 42 Iy The electronic control is protected by a 3 15A micro fuse The external control element and the actuator are each protected by a 0 25A micro fuse on the circuit board inside the equipment There is each one 3 15A micro fuse available for the heating dosing equipment and additional output The short circuit protection for the filter pump has to be ensured by customer provided pre fuses of max 16A Electronic motor protection The three phase current filter pump is protected against overload by an electronic motor protection For this the motor protection must be adjusted to the nominal current of the filter pump see type plate of the pump The adjusting controller for the motor protection is placed in the clamping box to protect it against inadvertent adjustment An optimum setting of the motor current is carried out with the help of a service terminal If the nominal current of the filter pump is unknown the motor protection can be set according
40. pling of the actuator encloses the valve axis and the bolt slides into the elongated hole of the coupling On doing so you have to take care that the coupling is not pushed back into the housing of the actuator and probably lifts the actuator Since due to dimensional tolerances of some valves the coupling does not always fit smoothly on the valve axis the shim must be held with both thumbs when locating the shim see sketch Subsequently turn the actuator rightwards to stop approx 45 After the slides have been released they now have to engage into the guiding grooves of the valve The valve axis must not be turned simultaneously on snapping on of the actuator The osf bolt in the valve axis now must be engaged into the elongated hole of the coupling Operating Instructions Euromatik 2000 Page 6 Electrical connection The electrical connection as well as any adjustment and service work may only be carried out by an accredited electrical specialist The enclosed connecting diagrams and the prevailing corresponding safety regulations are to be observed Mains supply for use of a 400V three phase current pump Euromatik 2000 EEAS TTT l l Pre fuses max B16A Protective winging Fl switch Filter pump 25A 0 03A 400V max 8A o Mains 3 N 400 230V 50Hz The factory provided inserted bridge between the clamps 15 and 16 must be removed if a pump with protective winding contact is connected If
41. rammed for each day of the week weekly timer In position OFF lower switch position it operates as a daily timer in the position ON top switch position as a weekly timer Backwash weekly or once a fortnight With code switch 3 you can choose if the backwash is carried out every week or only once a fortnight In the position OFF lower switch position every programmed backwash command is carried out In the position ON top switch position the first programmed backwash command is only carried out once a fortnight Any further backwash commands are not followed Skimmer or overflow gutter With code switch 4 you can choose the kind of the level control In the position ON top switch position a mini float switch is connected swimming pool with skimmer Attention no dry running protection in this operating mode In the position OFF lower switch position 5 hanging electrodes are connected gt swimming pool with overflow Operating Instructions Euromatik 2000 Page 20 gutter On delivery all 4 code switches are in position OFF i Service terminal To optimally adjust the control to various swimming pool equipment s as well as to facilitate an initial operation and error detection an osf service terminal item no 3010000900 can be connected to the control unit
42. rs have not been properly connected or the order has been mixed up Pump locked 13 37 The filter pump has been switched off by the protective winding contact or by a remote switch connected to the clamps 9 and 10 Pump overloaded The filter pump has been switched off by the electronic motor protection To switch on the pump again the key must be pressed after the pump has cooled Pump does not deliver The filter pump has been switched off by the press key connected to the clamps 17 and 18 or by the flow monitor To switch on the pump again the key must be pressed after the error has been cleared Net phase missing The filter pump has been switched off because there is no current in all three phases of the three phase current network To switch on the pump again the key must be pressed after the error has been cleared Sensor defect 13 37 The temperature control is out of operation because the temperature sensor is not connected or is defect Turn backwash The actuator turns in the direction of backwash Remain backwashs8 s The actuator is in valve position backwash Turn rinsing The actuator turns in the direction of rinsing Remain rinsing 5s The actuator is in valve position rinsing Turn filtering The actuator controls valve position filtering Turn draining The actuator tur
43. s waterproof The connecting line of the float switch should not be layed together with other live lines float switch In connection with the mini float switch a time delay is automatically activated in this operating mode This variable time delay prevents too many switching processes that could be caused by wave motions of the pool water The time delay may be extended or shortened by means of a service terminal For this also see further below in the text under service terminal Operating Instructions Euromatik 2000 Page 12 The mini float switch is mounted on the sliding angle Then the fastening bar is Skimmer wall vertically fixed at the inner skimmer wall roughly at the height of the requested water Tae N level The water level can be selected by gt moving the sliding angle in the fastening bar The sliding angle is then fixed by screwing in screw _ the screw All parts easily fit into one another Ss slide Si A making use of force unnecessary angle Zde floater switch ein schalter ie BE Water level floater i retaining ring _ fixation bar A Application without level control If the integrated level control is not used the clamps 43 44 45 and 46 must be interconnected Euromatik 2000 aalaalaa see7 ee Magnetic valve water backfeed A currentless closed magnetic valve is to be us
44. svaiahe esheets Qinhedes thine sb Gikv he AG RAGS DLO pinsos kidob Vitaea dastasi 5 Electrical connection iiss sence Siteoatie atic sgaea iin arscdg ete eae aa alae 6 Mains supply for use of a 400V three phase current pump sesosssesoossesoossessoesoseoesocssesoossessosseseossosssssosese 6 Mains supply for use of a 230V alternating Current pump sesoessesoossesoossessoesoseoesocssesoossossosseseossosesssossos 6 Connection of the b atihg s i scscssaccesssscoscesssecseseoscsacessececesonsetanes socesssossessensoicteesonsedsGesoddetesosesssnseeseoeseseatsseseeteee 7 Connection of the EUROMATIK actuator for the six port distributing valve sesssesssesssesscssssesssesssee 7 Operation of the control system without EUROMATIK actuator esssessoessocssocssocesscssscessecesocessesssesssee 7 Connection of the backwash pump se sseesseesseocsoocssoessoscocccooccooecosecooecooscosecooscooecooceooeeooessoeesocesoeesooesssesssessses 8 Connection of a backwash motor Valve tw0 port seeesseesocesccesoossocesooecooesoosesocesosesocesoessocssseessesssesssecesese 8 Additional connecting Possibilities csscssssccssssccsssccsssscssssccsssscsssssssessssssscessssssssssssassssssssnssssssascsssases 9 Connection of a press KY 2s sssscsiscccicteScoansssveccdesesoocnssssscevesnsooedestesecvedssssewsscsecesctusaseusseesecd odeseeceuses SSE ESPE roves E Sss 9 VELARA N ERE E EE E E EE E A E E O E 9 Swimming pools with flow off gutter
45. the first line of the service terminal the pump can be manually switched on or off 1 On pressing the key J the filter system is switched off and the following display appears Filter pump OFF Pump can be switched manually 2 With the key Al the filter pump can be switched on and with the key M it can be switched off again Attention In this operating mode the electronic motor protection is out of operation 3 If the key is pressed again the normal diagnostic display appears and the filter system continues to operate Solar operation If the operating mode of the solar heating is indicated in the first line of the service terminal it can be manually switched on or off 1 On pressing the key l l the filter system is switched off and the following display appears Solar system Manual operation Actuator OFF Pump OFF 2 With the key Althe solar heating can now be switched on and with the key Mit can be switched off again On switching on the solar heating the following display appears Solar system Manual operation Actuator ON Pump OFF 3 With the key A you can now additionally switch on the filter pump Attention In this operating mode the electronic motor protection is out of operation On switching on the _ filter pump the following display appears Solar system Manual operation Actuator ON Pump ON 43 44 45 Operating Instructions Euromatik 2000 Page 31 4 If the key Jis pressed aga
46. to the following process 1 Turn adjusting screw of the motor protection to the right stop 2 Switch pump on 3 Turn adjusting screw slowly anti clockwise as long as the motor protection triggers and the red error message flashes 4 Turn adjusting screw clockwise by some angular degrees approx 10 Unlock the motor protection with the key The error message stops flashing and the filter pump runs Daily timer Weekly timer DIP ON se aa gt fe Overflow groove Skimmer Operating Instructions Euromatik 2000 Page 19 Code switch For a universal use of the Euromatik 2000 for various filter systems there is a code switch available on the ciruit board that can be used to set various operating modes Switching over may only be carried out if the control is switched off The following functions can be set Daily or weekly timer filtering With code switch 1 you can choose if the built in timer should use the same filter periods every day daily timer or if the filter periods can be programmed for each individual day of the week weekly timer In the position OFF lower switch position it operates as a daily timer in the position ON top switch position as a weekly timer Daily or weekly timer backwash With code switch 2 you can choose if the built in timer should use the same backwash periods every day daily timer or if the backwash periods can be individually prog
47. uator Filt Output can be switched manually With the key Al the actuator can be started The requested valve position can be selected by repeatedly pressing the keys A or M The actuator automatically stops in the selected position The following displays can appear on the display Actuator Filt Output can be switched manually Actuator Backw Output can be switched manually Actuator Rinsing Output can be switched manually Actuator Draining Output can be switched manually Controlled position filtering Controlled position backwashing Controlled position rinsing Controlled position draining Subject to alterations June 15 Operating Instructions Euromatik 2000 Page 34
48. uromatik 2000 Page 9 Additional connecting possibilities Euromatik 2000 Dosing equip P P Dosing equip potential free ON OOF 230V max 3A max 4A Remote control or pool covering A 230V accessory device e g an underwater floodlight may be connected to clamp U4 This device can be switched on and off at will by using a key in the front lid or on the external operating element An additional 230V device e g dosing equipment may be connected to clamp U3 During the filter operation this device can be switched on together with the filter pump In the control unit there is a floating relay contact between the clamps 25 and 26 It can be used to control an additional dosing equipment in this case it is closed during the filter operation This contact can be charged with a maximum of 230V 4A A remote switch or the pool covering can be connected to the clamps 7 8 9 and 10 These clamps drive mains voltage Opening the contact between the clamps 9 and 70 causes an immediate switching off of the filter pump dosing equipment and heating Closing of the contact between the clamps 7 and 8 causes a switching on of the filter system Connection of a pressure switch Euromatik 2000 A pressure switch that can be installed in the pressure line or in the manometer connection of the central valve can be connected to the clamps 37 and 38 If the potential free contact of the press key is closed for at least 10