1.  release stroke  which can be useful in case  of thermal expansion of the clamping screw     3 2  Internal Clamping  MSPD     The clamping jaw approaches the workpiece  is prealigned  and jprentensioned by turning the external hexagon  SWT counter clockwise This automatically changes the  clamping direction to internal clamping  For this changeover  the threaded housing of the power clamping screw with  the jaw is maintained in a preloaded state and then  subjected to an axial motion in reverse direction  i e  the  external hexagon SWT should be turned by approx  one  turn extra without clamping stroke  The power clamping  with internal hexagon SW2 is then carried out in a similar  manner as the external clamping procedure  see 3 1       3 3  Release    Release is effected i n reverse order by turning the inter   nal hexagon SW2 counter clockwise until the fixed stop   see fig  A   The drive spindle is reversed and the clamping  system unclamped  The return spring  14  pushes the  threaded spindle with clamping jaw back  the force amplifier  returns to its initial position  By turning SW1 clockwise   or counter clockwise  the clamping jaw reaches the release  position     www jakobantriebstechnik de    4  Wartung    Das Gewinde der Antriebsspindel ist in geeigneten Intervallen   mind  1x pro Monat  mit Hilfe des Innensechskant  SW2 integrierten Schmiernippels  21  mit hochwertiger  Fettpaste nachzuschmieren  Der Kraftverst  rker ist  unter normalen Betriebsbedingungen wartung
2.  the clamping screws are principally  responsible for working safety    The observation of all applicable safety regulations and legal  obligations is required to avoid damages to persons and the  product during maintenance and repairs    The proper repair of products from Jakob Antriebstechnik GmbH  requires trained personnel  The training is for the operator or  repairer to ensure     7 3  Copyright    This set of operating instructions remains protected by copy   right and the intellectual property of Jakob Antriebstechnik  GmbH  They are provided to our customers and the operators  of our products    Without the express written consent  these instructions may  not be duplicated or handed over to a third party  particularly  to competitive companies of Jakob Antriebstechnik Gmbh     7 4  Spare Parts    Only use spare parts that meet the requirements of the  producer or supplier  These are always met by original spare  parts    Improper repairs  as well as wrong spare parts will void  product liability and the warranty    When ordering spare parts  it is mandatory to provide series   size and identification number of the power clamping screw  in order to prevent wrong delivery     7 5  Accessories    The required operating tools such as torque wrenches  force  measuring devices for clamping force control  or high quality  grease for the force amplifier can be supplied on request     www jakobantriebstechnik de    
3.  vor dem  Spannvorgang die Antriebsspindel mit dem Innensechskant  SW2 von der L  sestellung etwa eine Umdrehung    leer    vor   gedreht werden  dies ist dann die eigentliche Startposition  f  r das Vor  und Kraftspannen  Durch diese Ma  nahme steht  zudem ein gr    erer L  sehub zur Verf  gung  was z  B  bei  einer eventuellen W  rmeausdehnung des Spannk  rpers  von Vorteil ist     3 2  Innenspannen  MSPD     Durch Linksdrehen des Au  ensechskantes SW1 mit Hilfe eines  Ring  oder Steckschl  ssels wird die Spannklaue gegen das  Werkst  ck gefahren  vorausgerichtet und vorgespannt  Dabei  findet die automatische Umschaltung auf das Innenspannen  statt  F  r diese Umschaltung wird die Gewindespindel bei  anliegender Spannklaue entgegengesetzt axial verschoben   d h  der Au  ensechskant SWi muss hierf  r ca  eine  Umdrehung zus  tzlich ohne Spannhub bet  tigt werden  Das  Kraftspannen mit dem Innensechskant SW2 erfolgt analog  zum Au  enspannen  siehe 3 1       3 3  L  sen    Der L  sevorgang erfolgt in umgekehrter Reihenfolge  Durch  Drehen des Innensechskantes SW2 gegen den Uhrzeigersinn  bis zu einem hinteren Festanschlag  Bild A  f  hrt die Antriebs   spindel zur  ck und die Spannmechanik wird entlastet  Die  Druckfeder  14  schiebt die Gewindespindel mit Spannklaue  zur  ck und dr  ckt den Kraftverst  rker in die Ausgangsstellung   Durch Rechtsdrehen  bzw  Linksdrehen  des Au  ensechs   kantes SW1 wird danach die Spannklaue in die gew  nschte  L  sestellung gebracht     JA
4. 0  max  statische Belastung  600 kN   ku  MSPD 120  max  static load  600 kN   410     s     _       F  Ti        i W 20 30 40 50 60 70 80 90 W TW 120 TD WQ 150 10 Nm    MSPD 200  max  statische Belastung  1 200 kN   IkN1  FMSPD 200  max  static load  1 200 KN     H UAA  AAAA  HLA  LAAT  A iam    0 100 120 140 160 180  Nm        50    www jakobantriebstechnik de    7  Erg  nzung    7 1  Gew  hrleistung    Die Gew  hrleistung betr  gt 24 Monate ab Lieferdatum  Werk bei bestimmungsgem    em Gebrauch im 1 Schicht   Betrieb  max  10 000 Spannungen  und unter Beachtung  der vorgeschriebenen Wartungs  und Schmierintervalle   Grunds  tzlich sind Dichtungen  Dichtelemente  Ver   schraubungen  Federn  Schrauben und Abstreifer nicht  Bestandteil der Gew  hrleistung    Der Gew  hrleistungsanspruch erlischt  wenn Sch  den durch  unsachgem    e Bedienung entstehen  Zum Erl  schen jeg   lichen Gew  hrleistungsanspruches f  hren Reparaturarbeiten  oder Eingriffe  die von hierzu nicht erm  chtigten Personen  vorgenommen werden und die Verwendung von Zubeh  r und  Ersatzteilen  auf die unsere Spannspindeln nicht abgestimmt  sind     7 2  Wichtige Hinweise zu Sicherheitsvorschriften    Unabh  ngig von den in dieser Betriebsanleitung aufgef  hrten  Hinweisen  gelten die gesetzlichen Sicherheits  und Unfallver   h  tungsvorschriften sowie die EG Maschinenrichtlinien   Jede Person  die vom Betreiber mit der Bedienung  Wartung  und Instandsetzung der Spannspindel beauftragt ist  muss  vor Inbetrie
5. Antriebstechnik MS       BETRIEBSANLEITUNG OPERATING INSTRUCTIONS    Mechanische Spannspindeln Mechanical Power Clamping Screws  Baureihen MSP MSPD 50   200 Series MSP MSPD 50   200    TAALLLE    Inhalt  Contents    1  Montagezeichnung 1  Installation Drawing   2  Konstruktiver Aufbau und Funktion 2  Design and Function   3  Bedienung 3  Operation   3 1  Au  enspannen 3 1  External Clamping   3 2  Innenspannen 3 2  Internal Clamping   3 3  L  sen 3 3  Release   4  Wartung 4  Maintenance   5  Montagehinweis 5  Installation Notice   6  Spannkraftdiagramme 6  Clamping Force Diagrams   7  Erg  nzung 7  General Information   7 1  Gew  hrleistung 7 1  Warranty   7 2  Wichtige Hinweise zu Sicherheitsvorschriften 7 2  Important Notice Concerning Safety Regulations  7 3  Urheberrecht 7 3  Copyright   7 4  Ersatzteile 7 4  Spare Parts   7 5  Zubeh  r 7 5  Accessoires   8  Graphische Bedienungsanleitung 8  Operating Instructions   Graphic    stechnik GmbH   info jakobantriebstechnik de   www jakobantriebstechnik de       1  Montagezeichnung   1  Installation Draw  n                innen   internal au  en   external    Spannrichtung    clamping direction          17   16      2                     H    Weganzeige   path indicator       Bedienweg   operation path     14     Hr ILL  N        N 2  K    II 7   IL 222722 EI    AKOB  Antriebstechnik Y       J     1                  2  Konstruktiver Aufbau und Funktion    Die doppelt wirkenden mechanischen Spannspindeln der  Reihe    MSPD    si
6. KOB Antriebstechnik GmbH    info jakobantriebstechnik de    J    AKOB    Antriebstechnik       3  Operation    3 1  External Clamping  MSP   MSPD     The clamping jaw is prealigned and pretensioned by  turning the external hexagon SWT clockwise  A torque  wrench should be used for force clamping and fine  adjustment  By turning the internal hexagon SW2 clockwise  the drive spindle   s force amplification is activated to  and clamping force is generated proportionally to the  actuation torque until the torque wrench disengages  upon reaching the preselected torque  see clamping  force diagram   The clamping stroke can be controlled  va an operating path indicator  In case of  using the entire operating path up to a fixed stop  see fig  B   the torque wrench disengages without the screw reach   ing the required clamping force  For safety reasons  the  operating path should not be used entirely  revolutions of  SW2  Size 50   2 5x   Size 65   5x   Size 80   100   120   6x    Size 160   8x   Size 200   9x   The clamping procedure  has to be repeated by loosening SW2 and pretensioning  SWT  Avoid exceeding the maximum actuation torque as it  may cause damage    Notice    To keep the clamping jaw freely moveable in both clamping  directions  especially during fine adjustment  the drive spindle  with hexagon SW2 should be turned in the air approx   one turn from the unclamped state  This is the actual start  position for pre  and force clamping  This procedure also  ensures a larger
7. bnahme die Betriebsanleitung gelesen und ver   standen haben    Instandsetzer der Spannspindel sind f  r die Arbeitssicherheit  grunds  tzlich selbst verantwortlich    Die Beachtung aller geltenden Sicherheitsvorschriften und  gesetzlichen Auflagen ist Voraussetzung  um Sch  den an  Personen und dem Produkt bei Wartung sowie Reparaturar   beiten zu vermeiden    Die sachgem    e Instandsetzung der Jakob Antriebstechnik  GmbH Produkte setzt entsprechend geschultes Fachperso   nal voraus  Die Pflicht der Schulung obliegt dem Betreiber  bzw  Instandsetzer  Dieser hat Sorge daf  r zu tragen  dass die  Bediener und zuk  nftigen Instandsetzer f  r das Produkt fach   gerecht geschult werden     7 3  Urheberrecht    Die vorliegende Betriebsanleitung bleibt urheberrechtlich  Eigentum der Jakob Antriebstechnik GmbH  Sie werden  nur unseren Kunden und den Betreibern unserer Produkte  mitgeliefert und geh  ren zum Lieferumfang der Spann   spindeln    Ohne unsere ausdr  ckliche Genehmigung d  rfen diese  Unterlagen weder vervielf  ltigt noch dritten Personen  insbe   sondere Wettbewerbsfirmen  zug  nglich gemacht werden     7 4  Ersatzteile    Nur Ersatzteile verwenden  die den vom Hersteller bzw   Lieferer festgelegten Anforderung entsprechen  Dies ist bei  Originalersatzteilen immer gew  hrleistet    Unsachgem    e Reparaturen  sowie falsche Ersatzteile f  hren  zum Ausschluss der Produkthaftung bzw  Gew  hrleistung   Bei der Bestellung von Ersatzteilen ist es unumg  nglich  die  Type  G
8. ebstechnik de    2  Design and Function    The double acting mechanical power clamping screws of the  series    MSPD    are designed for    external     shafts  rollers   as well as    internal    clamping  pipes  bushes   These power  clamping screws are equipped with a    wedge mechanic     system as force magnifier  The MSPD is also equipped with  an automatic mechanism to change clamping direction   This system generates high clamping forces with a simple  operating procedure requiring low manual actuation torque   The state of the art    wedge mechanic    system is extremely  robust and self locking in every clamping stage  The high  stiffness achieved thus also increases operational safety     The force amplification mechanic is activated through rotation  of the drive spindle  4   which presses the threaded spindle  1   and jaw against the workpiece  Clamping force is generated  according to actuation torque  By changing the load direction  from    external    to    internal    the clamping direction within the  force amplifier automatically changes without the need for  a manual switching of directions  Correspondingly  the  clamping forces are passed on further depending on the  direction of clamping into the left bearing journal  2  during  external  or in the right bearing journal  3  during internal  clamping  The reverse motion of the force magnifier and  threaded power clamping screw is compensated by a  compression spring  14  which functions at the same time a
9. lso  as a return spring during unclamping     www jakobantriebstechnik de    3  Bedienung    3 1  Au  enspannen  MSP   MSPD     Durch Rechtsdrehen des Au  ensechskantes SW1 mit  Hilfe eines Ring  oder Steckschl  ssels wird die Spann   klaue gegen das Werkst  ck gefahren  vorausgerichtet und  vorgespannt  Zum Kraftspannen und Feinausrichten muss  ein Drehmomentschl  ssel verwendet werden  Durch  Drehen des Innensechskantes SW2 im Uhrzeigersinn wird die  Antriebsspindel bet  tigt und die Spannkraft proportio   nal zum Anzugsmoment aufgebaut  Die Spannkraft ist  erreicht  wenn der Drehmomentschl  ssel beim vorgegebenen  Anzugsmoment  siehe Spannkraftdiagramm  ausrastet   Der Spannhub kann   ber eine Bedienweganzeige  kontrolliert werden  Bei Ausnutzung des gesamten Bedien   weges bis zu einem inneren Festanschlag  Bild B  rastet  der Drehnmomentschl  ssel aus  ohne die geforderte Spann   Kraft zu erreichen  Der Bedienweg sollte deshalb zur Sicher   heit nicht voll ausgenutzt werden  Umdrehungen von SW2   Gr  50   2 5x   Gr  65   5x   Gr  80   100   120   6x   Gr  160   8x    Gr  200   9x   Ist das vorgegebene Anzugsmoment bis zum  Ende des Bedienweges nicht erreicht  Bild C   muss der  Spannvorgang durch L  sen mit SW2 und eventuellem Vor   spannen mit SW1 wiederholt werden  Um Besch  digungen  zu vermeiden  sollte das maximale Anzugsmoment nicht    berschritten werden    Hinweis    Damit beim Feinausrichten die Spannklauen in beide  Spannrichtungen bewegt werden k  nnen  sollte
10. nd f  r die Spannrichtung    au  en      Wellen  Walzen  und    innen     Rohre  Buchsen  konzipiert   Die Spannspindeln sind hierzu mit dem mechani   schen Keilspannsystem    MKS    als Kraftverst  rker  und einer Umschaltautomatik ausger  stet  Dieses System  erm  glicht h  chste Spannkr  fte bei einfacher manueller  Bedienung mit niedrigen Anzugsmomenten  Die optimierte  Gestaltung der robusten Keilmechanik gew  hrleistet eine  Selbsthemmung in jeder Spannstellung  sowie ein ho   hes Ma   an Steifigkeit  wodurch eine maximale Betriebs   sicherheit erreicht wird     Der Kraftverst  rkungsmechanismus wird durch Verdrehen  der Antriebsspindel  4  aktiviert  Dies bewirkt mittels der  Keilmechanik eine axiale Verschiebung eines Druckst  ckes   wodurch die Gewindespindel  1  mit Spannklaue gegen das  Werkst  ck gedr  ckt und die Spannkraft abh  ngig vom  Anzugsmoment aufgebaut wird  Durch die entgegengesetzte  Belastungsrichtung von    au  en    nach    innen      ndert  sich die Kraftflussrichtung im Kraftverst  rker automatisch   ohne das ein zus  tzlicher Umschaltvorgang erforderlich  ist  Somit wird die Spannkraft wechselweise beim Au  en   spannen in den linken Lagerzapfen  2  bzw  beim  Innenspannen in den rechten Lagerzapfen  3  eingeleitet und  abgest  tzt  Der Umschaltweg des Kraftverst  rkers und der  Gewindespindel wird von einer Druckfeder  14  kompensiert   die gleichzeitig als R  ckstellfeder beim L  sevorgang dient     JAKOB Antriebstechnik GmbH    info jakobantri
11. necessary to  compress the spring with a suitable device in order to push  the length below the installation length  The preload force of  the spring when installed is higher than the weight force of  screw housing and clamping jaw  vertical configuration      6  Spannkraftdiagramme aller Typengr    en   6  Clamping Force Diagrams   all series      MSPD 50  max  statische Belastung  150 kN   MSPD 50  max  static load  150 kN     Ah  Hl    a        jatt  u 4  hl  en El 70 Hmi    JAKOB Antriebstechnik GmbH    info jakobantriebstechnik de    www jakobantriebstechnik de    MSPD 65  max  statische Belastung  250 kN   unt FMSPD 65  max  static load  250 kN        O 0 2 3 4 50 6 70 80  N     MSPD 100  max  statische Belastung  400 kN   MSPD 100  max  static load  400 kN     III II III III  saa                                                           un 2 X MI 6 TW RR HO PO 1 m    F MSPD 160  max  statische Belastung  800 kN   KN MSPD 160  max  static load  800 kN     400  gt   Too  LLL  TT    240  200    160         KLI  ANE    120    Bs  u  IN  BERN  ESE  1 l  I  IL  Es   s      s  s   m    N       j      8      ANST   j      40  Tarii  10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160  Nm        JAKOB Antriebstechnik GmbH         info jakobantriebstechnik de      AKOB    Antriebstechnik       J                 L    F MSPD 80  max  statische Belastung  300 kN   KN MSPD 80  max  static load  300 kN                      Tarii  J  20 30    5 6 70 8 amp 0 30 100 INml    F MSPD 12
12. r    e und die Identifikationsnummer der Spannspindel  anzugeben  um Fehllieferungen zu vermeiden     7 5  Zubeh  r    Auf Anfrage k  nnen Sie die passenden Bedien  und Drehmo   mentschl  ssel  Kraftmessdosen zur Spannkraftkontrolle oder  das passende hochwertige Fett f  r den Kraftverst  rker erhalten     JAKOB Antriebstechnik GmbH      info jakobantriebstechnik de    AKOB  Antriebstechnik Y       J    7  General Information    7 1  Warranty    The warranty covers 24 months from the time of delivery  in case of single shift operation in accordance with regula   tions  10 000 clamping procedures max   and as long as the  mandatory maintenance and lubrication intervals are observed   Seals  sealing elements  screwing  springs  screws and wiper  rings are not covered by the warranty    The warranty is void if damages result from inappropriate  operation  Repairs or procedures carried out by unauthorized  persons will also void any warranty claims  So does the use of  accessories and spare parts  our power clamping screw is not  geared to     7 2  Important Notice Concerning Safety Regulations    Independent from the notices found in these instructions  the  statutory safety and accident prevention regulations apply as  well as the Machinery Directive ofthe EU  Each person that is  instructed to operate  maintain or repair the power clamping  screw by the operator  has to have read and understood these  instructions prior to putting the screw into operation   Personnel repairing
13. sfrei   Durch Entfernen der Verschlussschraube  17  kann jedoch  nach l  ngerer Einsatzzeit bzw  bei Bedarf die Keilspann   mechanik mit einer hochwertigen Fettpaste mit  Hochdruck  und Haftzus  tzen geschmiert werden  Das  Trapezgewinde der Spindel zur Spannklaue  sowie die  F  hrungen der Spannklaue sind ebenfalls bei Bedarf  z  B  mit hochwertigem Fett nachzuschmieren  Ungeeignete  Schmiermittel k  nnen die Funktion der Spanneinheit  negativ beeinflussen  Die Spannkraft sollte je nach  H  ufigkeit der Spannzyklen einmal im Jahr  bei hohen  Bedienzyklen mindestens zweimal im Jahr  gepr  ft werden   Weichen die erreichten Spannkraftwerte zu stark von  den vorgegebenen Sollwerten ab  ca  25    30    ist eine  generelle   berholung der Kraftspannspindel  inklusive einer  Kontrolle des Kraftverst  rkers  erforderlich  Die Montage und  Demontage des Kraftverst  rkers sollte nur durch geschultes  Fachpersonal vorgenommen werden     5  Montagehinweis    F  r den Transport und Einbau der Spannspindel kann das  Gewinde des Gewindestiftes  16  zur Befestigung einer Ring   schraube genutzt werden  Der Gewindestift ist nach der  Montage wieder einzuschrauben und zu sichern    Die Spannspindeln werden mit entspannter Druckfeder  14   ausgeliefert  F  r die Montage muss eventuell die Druckfeder  mit einer geeigneten Vorrichtung zusammengedr  ckt werden  um weniger als das Einbaul  ngenma   zu erreichen  Die  Vorspannkraft der Druckfeder ist im eingebauten Zustand  gr    er als die Gewich
14. tskraft von Spindelgeh  use und  Spannklaue  vertikale Anordnung      AKOB  Antriebstechnik Y       J    4  Maintenance    The thread of the drive spindle has to be lubricated in  suitable intervals  at least once a month  using the  lubrication nipple  21  integrated in the internal hexagon  SW2 and using high quality grease paste  The force  amplifier is maintenance free under normal operating  conditions  By removing the seal screw  17  the power  amplifier can be greased with high quality grease paste  with high pressure and adhesive additive  The trapezoi   dal thread of the spindle facing the jaw  as well as the guide  of the jaw have to be greased with high quality grease  paste as needed  Unsuitable lubrication can adversely  affect the function of the clamping unit  The clamping force  should be checked twice a year for high operational cycles   but at least once a year  If the measurements are too far  from the reference values  approx  25   30    the power  clamping screw has to go through a complete overhaul and  the power amplifier has to be checked  The installation and  removal should only be carried out by trained personnel     5  Installation Notice    For transportation and installation of the clamping screw   the thread of the threaded pin  16  can be used to fix a ring  bolt  The threaded pin has to be screwed back in and secured  after installation    The clamping screws are rolled out with an unstressed  pressure spring  14   For installation  it may be 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Samsung Επαγγελματική οθόνη FHD 23” με προηγμένο εργονομικό σχεδιασμό Εγχειρίδιο χρήσης  Car Digital Hard Disk Recorder User Manual  Lennox International Inc. G24M SERIES User's Manual  御見積書 - 脱臭装置  0H9060 RevB.indd - Northern Tool + Equipment  LAURIERS 2014 DU VOYAGE D`AFFAIRES Mode d`emploi pratique  Guía Docente - Universidad de Granada  Manuel - Cateye  Braun K 750 CombiMax Food Processor - D:\ELECTRONICA\braun\_food_processor_®_  Regolamento Edilizio Comunale    Copyright © All rights reserved. 