1. k Parts Illustrations Yale a i v2 s et Y AR Er 4 AA Alkaline oe g LO E 7 Batteries Template i Interior Exterior W Escutcheon Strike Plate Escutcheon Hex key amp 2 Lever Hex Set Screws Pack 1 A Cylinder Interior Mounting aa 2 Interior Mounting Plate Screws Plate with Gasket f 2 Exterior amp Interior Go CU Car Ue ep GP EP Ey back of Interior Escutcheon Ca Q Q Ca Lever Handles i 4 Interior Escutcheon 2 Latch amp 2 Strike Plate Mounting Mounting Screws Pack 1 Screws Pack 2 Tools Needed D N Door Prep Lock Installation 2 1 8 54mm hole saw m 2 Phillips screw driver 1 26mm boring bit Hex key 3mm provided 7 64 2 5mm drill bit Chisel amp hammer P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY INSTALL LOCK Preparation Before installing the lock on the door NOTE Make sure door has been prepped according to specifications in template included with lock A Remove the latch Fig A and strike plate from the packaging Both latch face and strike plate have adhesive backed covers to prevent marring and should be removed upon installation NOTE Latch ships with backset in 2 3 8 position Fig A Backset is the measurement from door edge to center of 2 1 8 diameter hole see template supplied with lock
2. Yale Real Living Push Button Lever Yale Installation and Programming Instructions NOTE TO INSTALLER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT AND VOID THE FACTORY WARRANTY For Technical Assistance call Yale at 1 800 810 WIRE 9473 This document is available on our website in printed Spanish and French Go to www yalecommercial com Click Product Information amp Documentation and then Installation Instructions Este documento est disponible en espa ol en nuestra p gina de internet Vaya a www yalecommercial com Presione Informaci n del Producto y Documentaci n y luego Instrucciones de Instalaci n Ce document est disponible sur notre site Web dans le fran ais imprim Allez www yalecommercial com Cliquez sur le Information sur le produit et Documentation et puis Installation Instructions P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY TABLE OF CONTENTS Warnings Introduction Installation Components and Tools Install Lock Programming Programming Features Menus Keys Definitions Operation Miscellaneous Information Hardware Troubleshooting Programming Troubleshooting Installing the Network Module Replace Install Cylinder Sample PIN Code Management Sheet WARNINGS Warning Changes or modifications to this device not expressly approved by Yale Security Inc could void the user s authority to operate the equipmen
3. INST FUL Rev E ASSA ABLOY Install Exterior Escutcheon and Interior Mounting Plate Holding the exterior escutcheon flush to the door position the interior mounting plate by first routing the wire harness through the mounting plate s 1 2 rectangular hole below center hole Fig 9 Secure both assemblies by inserting 2 M4 x 25 4mm pan Through posts here head machine screws through the mounting plate and into the slightly extended through posts of the exterior escutcheon Fig 10 Ensure that exterior escutcheon is vertically aligned Tighten securely with a 2 Phillips screwdriver Interior of Door Do not over tighten Figure 10 8 Finish routing the wire harness and connector through the left upper slot then behind center rib Fig 11 Interior of Door Figure 11 P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY Install Interior Escutcheon 9 Attach wire harness assembly to the interior escutcheon printed circuit board PCB by lining up notches on top of connector to slots on PCB connector Fig 12 amp 13 Press connector in firmly using thumbs until completely seated properly seated position indicated by arrows on PCB as in Fig 13 Interior Escutcheon Wire harness Connector Figure 12 Figure 13 10 Install and secure interior escutcheon to interior mounting plate using 4 M4 x 8mm pan hea
4. This is the Low Battery indicator alerting that it is time to replace the batteries Replace flashes all four 4 batteries with new AA Alkaline batteries Upon entering a PIN code and press The digits entered were incorrect or incomplete Re enter the correct code followed by ing the star key the unit responds the star key with a series of beeps and the keypad flashes three times When batteries are replaced Network Module locks have a real time clock that will be set through the User Interface it is recommended to verify correct date and time particularly those locks operating under Daylight Saving Time DST Network module units only P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY Installing the Network Module IMPORTANT The batteries must be removed prior to removing and or inserting the network module Remove battery cover Remove batteries Remove and or insert network module Reinstall batteries Use Feature Programming step 7 page 18 for enrollment of the Network Module Replace Install Cylinder 1 Remove cylinder A Repeat previous steps for removing the exterior lever handle B Remove cylinder Install new cylinder A Insert cylinder in exterior lever B Insert key in cylinder rotate the key 90 clockwise C Push handle in allowing holes for set screw to align D Insert set screw and
5. device on the door tance but the door will not open Check the door gaps for any foreign objects between door and frame Check that the wire harness is firmly connected to the PC board Unit operates to allow access but will Check to see if Automatic Re lock Mode is enabled not automatically re lock Disable Automatic Re lock Mode to lock the door automatically If low battery indicator is lit see below change batteries PIN codes will not register PIN codes must consist of 4 to 8 digits to register The same PIN code cannot be used for multiple users Registration management of PIN codes is set by the authority of the Master PIN Code Contact the Master PIN Code user User codes must be entered within 5 seconds or the process will have to be restarted The star a or pound HE cannot be used as part of the PIN code Upon entering a PIN code and press Lockout Mode is enabled ing the star key the lock gives a series of beeps flashes red and Only the Master PIN Code can enable disable Lockout Mode blue LEDs seven times and does Contact the Master PIN Code user not unlock Upon entering a PIN code and press Check to see if the lock is setto Lockout Mode ing the key there are different Setting managing Lockout Mode is done through Master PIN Code only Contact the ones Master PIN Code user The unit operates but it makes Enable Audio Mode no sound The unit displays intermittent RED
6. les interf rences qui peuvent causer un mauvais fonctionnement du dispositif INTRODUCTION The Yale Real Living Stand alone Push Button Lever Lock combines a robust lockset with a contemporary electronic aesthetic Users benefit from an interactive Push Button keypad that makes day to day access effortless for simple updates to user information in the event of staffing changes or security breaches Yale Real Living is engineered for quick and easy installation and fits in place of a standard lever lock door prep ANSI BHMA A156 115 If this is an RF enabled network lock it needs to be located within 30 50 feet of another network controller or a repeating device That distance is influenced by objects between the lock and the controller and may be expanded depending on proximity to other RF network devices Also if the lock is connected to a network controller it is recommended that it is programmed through the centralized user interface PC or hand held device to ensure communication between the lock and the controller unit P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY INSTALLATION COMPONENTS AND TOOLS Included in the box D _ Installation Instructions 2 Interior Mounting Plate Keys O Template with gasket Cylinder itaich Interior Escutcheon Battery Cover Strike Plate Exterior Escutcheon Hex key C 2 Screw Packs see below 4 AA Alkaline Batteries
7. will automatically re lock after a default of thirty 80 seconds Re lock time is adjustable from 10 180 seconds Inside Indicator Light Shows active status Locked of lock and can be enabled or disabled in the Advanced Lock Settings Main Menu selection 3 Low Battery When battery power is low the Status Indicator flashes RED If battery power is completely lost use the key override Master PIN Code The Master PIN code is used for programming and for feature settings It must be registered prior to programming the lock The Master code will also operate unlock lock the lock Network Module Setting With the optional Network Module installed this setting becomes available through the Main Menu 7 and allows the lock to connect with a network controller One Touch Locking When the latch is retracted activating the keypad will extend the latch during Automatic Re lock duration or when Automatic Re lock is disabled Privacy Mode Button Pressing and holding the Privacy button found below thumbturn for a duration of four beeps deactivates the keypad and because it is set from the inside provides a secure lock for the convenience of the occupant s Shutdown Time The unit will shutdown for a default of sixty 60 seconds time is adjustable from 10 180 seconds and not allow operation after the wrong code entry limit see below has been met When the unit is in Shutdown the Status Indicator flashes RED and BLUE the k
8. 250 with network module oe 3 E gt B gt BAD B gt 0 gt 8 Advanced Lock Settings E Y Automatic Re lock sonno 310 E Default settings in bold EE One Touch Locking Setting E E For quiet areas select Disable 3 in Audio Mode Disable ER 5 _ z Note If the lock is connected to a network controller NerworkModule sata g E itis recommended that it is programmed through the centralized user interface PC or hand held o a E gt E device to ensure communication between the lock maul installed and the controller unit P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY Open Door with PIN Code 1 2 3 Enter PIN code i Complete the code entry fT Unlock by pressing the key P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY MISCELLANEOUS Hardware Troubleshooting Programming Troubleshooting Installing the Network Module Replace Install Cylinder Sample PIN Code Management Sheet TROUBLESHOOTING Hardware Troubleshooting Cycle the lock in both the locked and the unlocked positions If problems are found Symptom Suggested Action Door is binding a Check that door and frame are properly aligned and door is free swinging b Check hinges They should not be loose or have excessive wear on knuckles Latch will not deadlock a Check for sufficient clearance of the latch within the strike side j
9. If required pull to extend to 2 3 4 backset position Fig A NOTE Different holes are used for 2 through bolts depending on backset See Fig A 2 3 8 through bolt posts Figure A 2 3 4 through bolt posts NOTE The latch can be installed in only one of two ways with the bevel slope of the latch facing out or facing in while standing exterior of the door If the door opens in the bevel will face the exterior regular if the door opens out the bevel will face the interior reverse IMPORTANT Latch bevel must match door bevel and plunger of deadlocking latch must stop on strike plate when door is closed E Strike plate Plunger P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY Install Latch 1 Install latch in door securing with two 2 M4 x 25 4mm screws supplied Fig 1 4 M4 x 25 4mm Flat Head Combination Screws 2 Install strike plate on the door frame using two 2 M4 x 25 4mm screws supplied making sure to allow for the latch to be centered in the strike plate Figure 1 Install Exterior Escutcheon NOTE The tops of both the square drive tube and the hub in the shank are marked to indicate their orientation for proper installation Figures A amp B NOTE RED marking indicates top of hub Tailpiece horizontal Square Drive Tube is marked WHITE to indicate top Exterior of Door Figure B Fig
10. amb Correct this by increasing the depth of the pocket for the latch b Check for misalignment of latch and or strike plate which may be preventing latch from properly entering the strike plate With the door open extend and retract the latch if it is smooth check the strike plate alignment Latch does not extend or retract smoothly a Latch and strike plate are misaligned see above b Check the backset of door relative to adjustments already made to latch c Verify proper door preparation and re bore holes that are too small or misaligned d Verify keypad wire harness is routed under the latch see Fig A e Verify latch is installed with correct side up Fig A Interior of Door Figure A P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY Programming Troubleshooting D Symptom Suggested Action Lock does not respond door is Press each keypad button to see if they respond when pressed open and accessible Check batteries are installed and oriented correctly polarity in the battery case Check batteries are in good condition replace batteries if discharged Check to see if wire harness is fully connected and not pinched Lock does not respond door is Batteries may be completely discharged Use mechanical key to gain entry and locked and inaccessible replace batteries Unit chimes to indicate code accep Check to see if there is another locking
11. d machine screws through the interior escutcheon into the mounting plate see Fig 14 Thumbturn must be in vertical position NOTE Verify that wire harness is not being pinched or damaged while installing mounting screws Thumbturn in vertical position Figure 14 P N AYRT 210 INST FUL Rev E ASSA ABLOY An ASSA ABLOY Group brand Determine Lever Handing Right Hand Hi ight Hand Reverse Hinges on Left Hand Hinges on left open Left Hand Reverse Hinges on left Ia For Than pe locke right opens ght opens outward For handed inward For handed locks opens outward For handed loeks specify AH ieks specify RHR specify LH specify LHR Hinges on Right p lt Hinges on Left Right handed Left handed lever position lever position Both exterior and interior lever handles should always point toward the door hinges Determine Lever Position gt Before proceeding with the next step ensure correct lever handing for proper installation a D a gt 2 Correct curved position Correct curved position Incorrect Incorrect Y A Important Note Follow the detailed instructions for cylinder installation starting with step 13 on page 11 of the installation and programming manual Next perform the operation tests defined in step 20 on page 13 of the installation and programming manual Failure to install and test t
12. d receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY Industry Canada Canadian ID 6982A YRHCPZWO0 Z Wave 6982A YRHCPZBO Zigbee This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Cet appareillage num rique de la classe B r pond a toutes les exigences de l interf rence canadienne causant des r glements d quipement L op ration est sujette aux deux conditions suivantes 1 ce dispositif peut ne pas causer l interf rence nocive et 2 ce dispositif doit accepter n importe quelle interf rence re ue y compris l interf rence qui peut causer l op ration peu d sir e For the U4A YRHCPZBO and 6982A YRHCPZBO the following statement applies This equipment complies with FCC IC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator and your body This transmitter must not be co located or operating in conjunction with any other antenna or t
13. er Codes can only be programmed through the Master PIN Code 1 Enter the 4 8 digit Master PIN code followed by the a key 2 Enter followed by the Ed key 3 Enter followed by the key 3 Enter the User number 1 25 to be registered followed by the a key 4 Enter a 4 8 digit PIN code for the User number followed by the H key Note When registering User codes the code must be entered within 20 seconds If time expires no codes are registered and the process must be re started Protect your privacy always shield your PIN code entry P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY To reset the lock to factory default see the following Reset Lock to Factory Default Reset Button The following procedure returns the lock to its factory defaults by deleting all user codes including the Master PIN code and returning all programming features to their original default settings see below 1 Remove the batteries and then remove the interior escutcheon to access the reset button The reset button see image at right is located above the PCB cable connector Hold down the reset button for a minimum of 3 seconds and then reinstall the batteries once the batteries are properly installed release the reset button All features including adjustable settings see below should now be returned to factory default Upon reset Master Code Registration is the only
14. eypad flashes as well Tamper Alert Audible alarm sounds if attempting to forcibly remove outside lock from door User PIN Code The User code operates the lock Maximum number of user codes is 250 with Network Module without Network Module maximum is 25 user codes Wrong Code Entry Limit After a specified number of unsuccessful attempts at entering a valid PIN code the unit will shut down and not allow operation Default setting is 5 Limit is adjust able from one 1 to ten 10 times Adjustable only when using Network Module with compatible integrated controller P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY OPERATION Register Master PIN Code Before Programming gt 1 Press the E key to enter Master PIN Code Registration 2 Press W followed by the a key 3 Enter a unique 4 8 digit Master PIN code followed by the a key Press the amp key to enter Master i Enter the key followed by the il Enter a 4 8 digit Master PIN code Code Registration goai B key followed by the key This initial step must be performed upon installation or after resetting the lock to factory default Programming and subsequent use of the lock is not possible until this step has been successfully completed PIN code structure Maximum number of user codes is 250 with Network Module without Network Module maximum is 25 user codes User PIN Code Registration Us
15. he cylinder for proper function may result in improper lock operation P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY Install the Exterior Lever 11 Remove clip from exterior escutcheon shank A Once correct handing is determined remove the clip that has held the hub in its correct position by spreading clip ends to extract clip from shank as shown in Figure 15 A Do not rotate cam from its original position Top is marked RED Figure 15 12 Install hex set screw A Place set screw in hole on side of shank toward latch Fig 16 turn set screw clockwise CW to allow placement of lever handle over shank Do not overtighten NOTE For correct lever handing the hex set screw for the exterior lever shank must be installed as shown Fig 16 Hex Set Screw CW Figure 16 RH RHR 13 Install cylinder in exterior lever Tailpiece If necessary remove key from cylinder A Install cylinder in exterior lever handle as shown in Figure 17 B Insert key in cylinder While supporting cylinder tailpiece with finger rotate key 90 clockwise CW to vertical position regardless of lever handing See Figure 18 P N AYRT 210 INST FUL Rev E ASSA ABLOY An ASSA ABLOY Group brand NOTE Hex set screw should be inserted far enough for handle to slide over shank clearing the set screw C Ensure that cylinder key remains in previously set ve
16. ight O 2012 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without express written permission of Yale Security Inc an ASSA ABLOY Group company is prohibited YALE with its unique global reach and range of products is the world s favorite lock the preferred solution for securing your home family and personal belongings ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user needs for security safety and convenience P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY
17. in shank 20 Secure lever handle by inserting hex key and rotating set screw CCW Fig 23 This will retract the set screw back into the lever handle to secure it in place Do not overtighten A Remove hex key ADOS igure IMPORTANT Before installing the batteries test the lock s mechanical operation Place the thumbturn in the horizontal position Lift up and push down on both the interior and exterior levers one at a time to verify that the latch is retracted by both levers in the un locked position Next place thumbturn in the vertical position Lifting up or pushing down on the exterior lever should not retract the latch Lifting up and pushing down on the interior lever should still retract the latch in the locked position Finally insert key in cylinder and rotate clockwise until thumbturn moves to horizontal unlocked position If operation is not smooth for any of these procedures review the previous steps to ensure proper installation while maintaining proper alignment of escutcheons Install Batteries 21 Insert four 4 AA alkaline batteries the lock will respond with flashes and beeps 22 Install battery cover and tighten Phillips head screw Figure 24 P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY PROGRAMMING Programming Features Menus Keys Definitions Operation PROGRAMMING FEATURES MENUS KEYS DEFINITIONS Exterior Interio
18. option available and must be performed prior to any other programming of the lock See Operation in this manual for programming instructions Interior Escutcheon Factory Default Settings Settings Factory Default Master PIN Code Registration required Automatic Re lock Disabled Inside Indicator Light Disabled Off One Touch Locking Enabled Audio Enabled Automatic Re lock Time 30 Seconds Wrong Code Entry Limit 5 Times Shutdown Time 60 Seconds The Master PIN code must be registered prior to any other programming of the lock Adjustable only when using Network Module with a compatible itegrated controller P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY Feature Programming Through Menu Mode Using Master PIN code gt 1 Enter the 4 8 digit Master PIN code followed by the a key 2 Enter digit corresponding to the function to be performed followed by the key Note If the lock is connected to a network controller it is recommended that it is programmed through the centralized user interface PC or hand held device to ensure communication between the lock and the controller unit A unique Master PIN Code must be entered prior to any further programming of the lock See section on page 16 Register Master PIN Code Before Programming 1 2 User Number UN m 25 without network module M Hm eee gt Men 1
19. r Phillips Head Screw Battery Cover Status Indicator E Network Module Slot Numbers Alkaline Batteries 4 AA Type Cylinder Indicator LED A unique Master PIN Code must be entered prior to any further programming of the lock See section on page 16 Register Master PIN Code Before Programming Menu and Icons Used in This Guide a O Click the indicated number n Enter Master PIN code 4 8 digits in length Press the Star key on the keypad to Enter or EN Enter User PIN Can be 4 8 digits in length Accept entry E Press the Pound key on the keypad to enter qa User Number 1 25 Menu mode RF Controlled 1 250 P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY Status Indicators O Low Battery Warning 5 Definitions All Code Lockout Mode This feature is enabled by the Master code When enabled it restricts all user except Master PIN code access When attempting to enter a code while the unit is in Lockout the Status Indicator flashes RED and BLUE 8 times the keypad flashes as well Audio Mode Choosing Disable 3 in Audio mode shuts off the code confirmation tone play back for use in quiet areas Audio mode is enabled or disabled through feature programming by the Master PIN code Automatic Re lock Time After successful code entry and the unit unlocks it
20. ransmitter Section 7 1 2 of RSS GEN Under Industry Canada regulations this radio transmitter may only operate using an antenna of a type and maximum or lesser gain approved for the transmitter by Industry Canada To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication En vertu des r glements d Industrie Canada cet metteur radio ne peut fonctionner avec une antenne d un type et un maximum ou moins approuv s pour gagner de l metteur par Industrie Canada Pour r duire le risque d interf rence aux autres utilisateurs le type d antenne et son gain doivent tre choisies de facon que la puissance isotrope rayonn e quivalente PIRE ne d passe pas ce qui est n cessaire pour une communication r ussie Section 7 1 3 of RSS GEN This Device complies with Industry Canada License exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Cet appareil est conforme avec Industrie Canada RSS standard exemptes de licence s Son fonctionnement est soumis aux deux conditions suivantes 1 ce dispositif ne peut causer des interf rences et 2 cet appareil doit accepter toute interf rence y compris
21. rtical position Fig 19 14 Push exterior lever handle over shank until hole on handle aligns with set screw in shank Hex Lever Set Screw Figure 19 Secure lever handle by inserting hex key Fig 20 and rotating set screw counter clockwise CCW This will retract the set screw back into the lever handle to secure it Do not overtighten A Remove hex key 16 Turn key 90 CCW to horizontal position regardless of lever handing Pull to remove key Fig 20 and test operation of lever ensuring that latch moves smoothly Figure 21 IMPORTANT Test the lock s mechanical operation Lift up and push down on lever handle to retract the latch ensuring that latch moves smoothly If operation is not smooth for these procedures review the previous steps to ensure proper installation while maintaining proper alignment of escutcheons P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY Install the Interior Lever 18 Install hex set screw NOTE Thumbturn should still be in horizontal position A Place set screw in hole on side of shank toward latch Fig 22 turn set screw CW to allow for placement of lever handle over shank Do not overtighten NOTE Hex set screw should be inserted enough for lever handle to slide over Figure 22 shank clearing set screw 19 Place interior lever handle over shank until hole on handle aligns with set screw
22. t IMPORTANT The accuracy of the door preparation is critical for the proper functioning and security of this product Misalignment can cause performance degradation and a lessening of security Finish Care This lockset is designed to provide the highest standard of product quality and perfor mance Care should be taken to ensure a long lasting finish When cleaning is required use a soft damp cloth Using lacquer thinner caustic soaps abrasive cleaners or polishes could damage the coat ing and result in tarnishing FCC FCC ID U4A YRHCPZWO Z Wave U4A YRHCPZBO Zigbee This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy ana if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful Interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment an
23. tighten by turning set screw counter clockwise E Verify that new cylinder fits and rotates freely F Test operation of the new cylinder key P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY PIN CODE MANAGEMENT SAMPLE SHEET PIN Code Management User Name User Type Master User User___ User wef we C a C ee we wef e C C T ee C e ee e ee a e ee e C e ee C CN we C a User User__ User__ User__ User User___ User User___ User User__ User User__ User__ User___ An ASSA ABLOY Group brand With Network Module Up to 250 Users fe User Duplicate Sheet to record entries User Name PIN Code la P N AYRT 210 INST FUL Rev E ASSA ABLOY ONLINE LITERATURE AND TEMPLATES For the latest information on Yale products visit our website at www yalelocks com Click on the Literature button to find the most up to date catalogs parts manuals templates specifications and installation instructions Scan this code to view installation videos for this and other Yale Real Living products Yale Locks 8 Hardware 100 Sargent Drive New Haven CT 06511 e Product Support Tel 800 810 WIRE 9473 e www yalelocks com Yale Locks amp Hardware is a division of Yale Security Inc an ASSA ABLOY Group company Yale is a registered trademark of Yale Security Inc an ASSA ABLOY Group company All rights reserved Yale Real Living is a trademark of Copyr
24. ure A Exterior Escutcheon with gasket Do not remove clip from Exterior Escutcheon shank until correct handing has been determined and Exterior Lever Handle is to be installed See pages 10 11 P N AYRT 210 INST FUL Rev E An ASSA ABLOY Group brand ASSA ABLOY 3 From outside of door position the exterior escutcheon by first routing the wire harness through 2 1 8 diameter hole and under the latch Fig 4 amp 5 then inserting the through posts and tailpiece square drive tube into the latch Fig 5 Exterior of Door Figure 4 Tailpiece horizontal A Interior of Door Top of Drive Tube marked WHITE Figure 5 NOTE Wire harness goes under latch Fig 4 4 5 Posts are inserted in holes according to backset adjustment Refer to Fig A under Lock Preparation 4 Remove the interior mounting plate with gasket from the back door side of the interior escutcheon Fig 6 Interior Escutcheon amp Mounting Plate with gasket A Ensure that gasket on interior mounting plate is properly fitted Fig 7 Figure 6 Figure 7 5 Remove the battery cover from the back of the interior escutcheon Fig 8 by loosening the captive Phillips head screw then lifting the cover up and out Note tabs at bottom of cover An ASSA ABLOY Group brand Figure 8 Phillips Head Screw Battery Cover P N AYRT 210

Download Pdf Manuals

image

Related Search

Related Contents

G-Flex Instructions no home link.indd  Plantronics Explorer 230  Manual de Usuario Plan Sueldos  EMMA Mobile1 Application Note SPI Interface  PALIER 1 : A1 A2  1E41QMB Service Manual (Chain-Driven 2T)  HiPER 840G  Betriebsanleitung HELIO-STROB ALPHA, BETA, BETA A2 (DE)  Instrucciones de funcionamiento y de montaje  2. Como se afirmó en el numeral 5.1, la humedad atmosférica es  