1. AX PLEASE READ AND FOLLOW ALL WARNINGS f Read Operating Instructions Always become familiar with all the instructions and warnings before operating any power tool Always Wear Approved Eye Protection Impact resistant eye protection should meet or exceed the standards as set forth in the United States ANSI Z87 1 Occupational and Educational Eye and Face Protection Look for the marking Z87 1 on your eye protection to insure that it is an approved style For further information ANSI Z87 1 Occupational and Educational Eye and Face Protection is available from the American National Standards Institute Inc 11 West 42nd Street New York NY 10036 Hearing Protection is Recommended Hearing protection should be used when the noise level exposure equals or exceeds an 8 hour time weighted average sound level of 85 dBA Process noise reflective surfaces other tools being operated nearby all add to the noise level present in your work area If you are unable to determine your noise level exposure we recommend the use of hearing protection Avoid Prolonged Exposure to Vibration Tools can vibrate during use Prolonged exposure to vibration or very repetitive hand and arm movements can cause injury Stop using any tool if discomfort tingling feeling or pain occurs You should consult your physician before resuming use of the tool 90 PSIG Maximum This tool is designed to operate at an air pressure of 90 p
2. Anvil Bushing Hammer Case Screw Oil Seal Steel Pipe Nut Spring Pin Washer Muffler Cover Ceramic Balls O Ring Gasket fa Z E E INS ek a E eS Sa ee e E SIN ND E E e E St SY Tes te RD
3. instructions could result in personal injury and or property damage Retain these instructions for future reference devices as furnished by the manufac turer Where an air tool is modified or altered the modifier shall provide the safeguards to enable it to be safely used in the operations intended and to comply with any applicable provisions as contained in CAGI B186 1 2009 Tool Installation Pressure regulators shall be used to limit air pressure to the rated pressure where the supply pressure exceeds the tool s rated pressure Air hoses and lines shall be relieved of compressed air before being disconnected or disjointed unless there is automatic valve closing protection at the joint being separated Synthetic lubricants which can cause deterioration of elastomer seals shall not be used in air systems of air tools Tool Maintenance It shall be the tool owner s and or employer s responsibility to assure that tools are maintained in a safe operating condition Tool maintenance and repair shall be performed by authorized trained competent personnel Tools shall be disconnected from their compressed air supply before repairs are attempted Repairs shall be consistent with the manufacturer s recommended procedures Tool hoses and fittings shall be replaced if unsuit able for safe operation It shall be the tool owner s and or employer s respon sibility to keep required rating markings and warnings on the tool
4. creased power output e Composite housing reduces weight to only 4 5 Ib FP 743A 1 2 in Composite Impact Wrench e Triple heat treated alloy steel hammer hammer cage amp anvil Safety Instructions The following instructions are fur nished as general guidelines for use of your pneumatic tool They cannot comprehensively cover all possible or conceivable uses of the subject tool For additional information on the safe use of air tools we advise you to obtain a copy of CAGI B186 1 2009 Safety Code for Portable Air Tools available from the following source COMPRESSEDAIRAND GAS INSTITUTE 1300 Sumner Avenue Cleveland OH 44115 2851 Ph 216 241 7333 www cagi org OR from Florida Pneumatic Manufacturing Corp 851 Jupiter Park Lane Jupiter FL 33458 561 744 9500 www florida pneumatic com The use of the word shall in the following instructions indicates that adherence to the particular require ment is necessary to conform to CAGI B186 1 2009 Tool Application and Usage Portable tools shall be used only for the purposes intended in their design and within the capacity for which they were intended and rated It shall be the tool owner s and or employer s responsibility to instruct each operator in the safe use of the tool Tools shall not be used without guards and safet Read these instructions carefully before attempting to install operate or service this Florida Pneumatic product Failure to comply with the
5. dequate proof of purchase date with a brief description of the defect Florida Pneumatic will at its option repair or replace defective tools free of charge Repairs or replacements are warranted as described above for the remainder of the warranty period Florida Pneumatic s sole liability and your exclusive remedy under this warranty is limited to repair or replacement of the defective tool There are no other warranties expressed or implied and Florida Pneumatic shall not be liable for incidental consequential or special damages or any other damages costs or expense of repair or replacement as described above R 1 2 3 4 5 6 7 8 9 ef Description Ref Housing Bushing Seal Screw Valve Seat Throttle Valve Valve Spring Exhaust Deflector O Ring Connector Spring Pin O Ring Air Inlet Bushing O Ring Trigger Ornamental Gasket O Ring Reverse Switch Valve Bushing Reverse Bushing Spring Steel Ball End Cap Cap Screw Gasket Ball Bearing Cylinder Part No 9106073 9106074 9106075 9106076 9106077 9106078 9106079 9106080 9106081 9106082 9106083 9106084 9106085 9106086 9106087 9106088 9106089 9106090 9106091 9106092 9106093 9106094 9106095 9106096 9106097 9106098 9106099 9A00003 Description Steel Ball Retainer Ring Rotor Rotor Blade Front End Plate O Ring Oil Seal Ball Bearing Ornamental Gasket Hammer Cage Hammer Dog Hammer Pin Anvil O Ring Socket Retainer Steel Sleeve
6. in legible condition FP 743A 1 2 in Composite Impact Wrench Specifications DP IVE SIZ Gs secceceersitcens ieee ee rete an 1 2 Impacts per MINUte sssessessesssserssseesssseesssseosseressse 1100 IPM Free speed No LOA ssccissssesscccsstsssstsresesnsasieteusesees 7000 RPM Ultimate tOrqUe s sssssssssessessessssssssssseeeeensssssssseee 580 ft Ibs Weg eemenene reer ae eee are apereie at EE 4 12 Ibs Overall lengthens 7 1 2 Average air CONSUMPTION c cccsscescescessossessesssennenes 6 SCFM Recommended NOSE SIZE essesssessesseesssesecsscessesscens 3 8 I D Air iN Etien menina An 1 4 NPT Maximum Air PreSSUre ssssessssssssssesssssessssesssseesssseessse 90 PSI USE ONLY IMPACT SOCKETS amp ACCESSORIES Sockets and accessories used shall be of the impact socket type Always check sockets retainers and drives regularly for wear or damage and replace whenever necessary Limited Warranty Florida Pneumatic warrants its tools to be free from defects in material and workmanship for two years from the date of purchase This warranty does not apply to tools which have been abused misused modified or repaired by someone other than Florida Pneumatic or its authorized service centers If a Florida Pneumatic proves defective in material of workmanship within two years after purchase return it to any authorized service center or to Florida Pneumatic freight prepaid Please enclose your name address and a
7. ounds per square inch gauge pressure 90 PSIG maximum at the tool Use of higher air pressure can and may cause injury Also the use of higher air pressure places the internal components under loads and stresses they were not designed for causing premature failure The air supply should be clean and dry preferably lubricated For best results drain the moisture from your compressor daily WARNING Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to cause cancer birth defects or reproductive harm Some examples of these chemicals are Lead from lead based paints Crystalline silica from bricks cement and other masonry products Arsenic and chromium from chemi cally treated lumber Your risk from these exposures varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment such as those dust masks that are specially designed to filter out microscopic particles f aa _ _ m re ao al h a Ra k Eege E 2 a mermi ui I k te a a aviary z g zA Se a i a 1 ast r o a PA Sea a ton i Florida Pneumatic Manufacturing Corporation 851 Jupiter Park Lane Jupiter Florida 33458 Toll Free 1 800 327 9403 air TOOLS Features e Combined reverse power management e Twin hammer clutch for in