Home

Husky HDUFL50 Use and Care Manual

image

Contents

1. Not shooting fasteners 0 Damaged pusher spring O Replace spring O Wrong size of fasteners O Use 1 2 in crown staples or 1 1 2 in to 2 in L cleat or T cleat nails Fasteners are jammed O Drive channel is worn O Fix the drive channel in the tool frequently O Piston is broken or worn O Replace the piston OU Bent fasteners O Remove the bent fasteners O Dirty magazine O Clean magazine Loose magazine O Tighten screws O Wrong fasteners O Verify that fasteners are the correct size Question Problems missing parts Before returning to the store call Husky Customer Service 8a m 6 p m EST Monday Friday 1 888 43 HUSKY HUSKYTOOLS COM Retain this manual for future use 14 15 HUSKYTOOLS COM Please contact 1 888 43 HUSKY for further assistance Tabla de Contenido Tabla de contenido 17 Informac n de seguridad 18 S mboloS 77 7 n cence nen nenneee 18 Area de trabajo 18 Seguridad personal 18 Uso y cuidado de la herramienta 19 Reparaci n de la herramienta 21 Fuente del aire 21 Funcionamient0
2. 6 Loading tool 6 Warranty 6 Unpacking 7 Specification 7 F atures lt 42assse ne noni 8 Operation nono n nen nen nn en ewe n nnn mm 8 Loading cleat nailS 8 Loading staples 8 Unloading cleat nails and staples 9 Change the foot plate 9 Adjust the front foot 9 Setting the air pressure 10 Operating the tool 10 Clearing jamS 11 Maintenance 11 Anti dust Cap 11 Lubrication 11 Cleaning 12 Cold weather operation 12 Recommended hookup 13 Troubleshooting 14 2 Safety Information A thoroughly and understand it completely Save this WARNI
3. 0 21 GUIA DE USO Y MANTENIMIENTO Entrada de aire y conexiones 21 Cargar la herramienta 22 Garant a 22 CLAVADORA PARA PISOS 3EN 1 E E E E EN AS 23 PARA GRAPAS Y LISTONES EN TY L Especificaciones airada 23 Caracter sticas oros 24 Operac on 24 C mo cargar listones 24 Preguntas problemas o piezas faltantes C mo cargar grapasS 24 Antes de regresar a la tienda llama al C mo cargar listones los grapas 25 Servicio al Cliente de Husky C mo cambiar la placa base 25 de lunes a viernes entre 8 a m y 6 p m C mo ajustar la pata frontal 25 hora del Eete de EE UU C mo configurar la presi n de aire 26 C mo usar la herramienta 26 C mo retirar sujetadores atascados 27 1 888 43 HUSKY Mantenimiento 28 Funci n antipolvo 28 HUSKYTOOLS COM Lubricaci n 28 Limpieza 7 29 Operaci n en climas fr OoS
4. 2 Durante el uso normal la herramienta se rebobinar de inmediato luego de accionar un sujetador Esta es una funci n normal de la herramienta No intente evitar la rebobinaci n sosteniendo la herramienta en contra del funcionamiento La restricci n para rebobinar puede provocar que se accione un segundo sujetador desde la herramienta Sujete la manija firmemente y permita que la herramienta realice el trabajo No seguir esta advertencia puede provocar graves lesiones personales 3 No coloques fijadores sobre otros fijadores o con la herramienta a un ngulo demasiado inclinado ya que esto puede causar el desv o de los fijadores y provocar lesiones 4 No uses la herramienta a menos que pretendas colocar un fijador en la pieza de trabajo 5 Opera siempre la herramienta con cuidado 21Sp O Respeta la herramienta como implemento de trabajo O Nunca la uses en bromas y juegos O Mant n a los dem s a una distancia segura de la herramienta ya que puede accionarse accidentalmente y posiblemente causar lesiones ENTRADA DE AIRE Y CONEXIONES 1 El conector de la herramienta no debe estar bajo presi n al desconectar la entrada de aire Si se utiliza un acoplador incorrecto la herramienta puede quedar cargada de aire luego de la desconexi n y podr a disparar fijadores incluso con la l nea de aire desconectada y ello puede causar lesiones 2 No utilice ning n tipo de gases reactivos lo que incluye pero no se
5. Most plastics are susceptible to damage from various types of commercial solvents and maybe damaged by their use Use clean cloths to remove dirt dust oil grease etc CAUTION Do not at any time let brake fluids gasoline petroleum based products penetration oils ect come in contact with plastic parts Chemicals can damage weaken or destroy plastic which may result in serious personal injury Cold weather operation For cold weather operation near and below freezing the moisture in the air line may freeze and prevent tool operation We recommend the use of air tool lubricant or permanent antifreeze ethylene glycol as a cold weather lubricant CAUTION Do not store tools in a cold weather environment to prevent frost or ice formation on the tools operating valves and mechanisms that could cause tool failure Recommended hookup O The air compressor must be able to maintain a minimum of 70 psi when the tool is being used An inadequate air supply can cause a loss of power and inconsistent driving O An oiler can be used to provide oil circulation through the tool A filter can be used to remove liquid and solid impurities which can rust or gum up internal parts of the tool O Always use air supply hoses with a minimum working pressure rating equal to or greater than the pressure from the power source if a regulator fails or 150 psi whichever is greater Use 3 8 in air hose for runs u
6. Repeat this process until the job is completed When finished make sure to store the tool in a clean dry safe location out of reach of children and other unauthorized people O WARNING Extreme caution must be used whenever this tool is connected to an air source If the tool is A dropped or if the hammer cap K is accidentally struck then the tool will fire a fastener potentially causing SERIOUS PERSONAL INJ URY AN WARNING Keep your feet off the tool WARNING Before using the tool on a floor test the tool on a scrap piece of wood Adjust the driving depth by providing more or less air pressure Never exceed 115 psi Hand grip J Hammer cap K A Operation Continued be used Do not actuate the tool unless the tool is A WARNING An improperly functioning tool must not placed firmly against the work piece NOTE Make sure the hammer cap on the flooring nailer is inthe up position before adding the air hose if not the nailer may cycle See below Hammer Cap Up Position Hammer Cap Down Position Q clearing jams Occasionally fasteners may become jammed in the firing mechanism of the tool making the tool inoperable To remove a jammed fastener follow the steps below O Disconnect the tool from the air source o Empty the magazine Make sure all fasteners are removed Try to fire the
7. aprobadas por ANSI La protecci n de los ojos se utiliza para resguardarlos de los fijadores y residuos que puedan saltar los cuales pueden causar lesiones graves en los ojos 3 Usa siempre protecci n auditiva cuando utilices la herramienta La exposici n prolongada a ruidos de alta intensidad puede causar la p rdida de la audici n 4 Usa un equipo de seguridad Se deben usar una m scara antipolvo calzado de seguridad antideslizante y un casco r gido en condiciones donde sean necesarios Usa una m scara protectora completa si est s trabajando con virutas de madera o limaduras de metales 5 Usa la vestimenta adecuada No utilices ropa o joyas sueltas Recoge el cabello largo Mant n el cabello la ropa y los guantes alejados de las partes m viles La ropa y las joyas sueltas o el cabello largo pueden quedar atrapados en las partes m viles 6 Cuando utilices una herramienta de motor mantente alerta observa lo que est s haciendo y utiliza el sentido com n No utilices la herramienta si est s cansado o bajo el efecto de drogas alcohol o medicamentos Un momento de distracci n durante la operaci n de la herramienta puede causar lesiones graves 7 Mant n siempre una posici n firme y el equilibrio adecuado Una posici n firme y el equilibrio adecuado permiten controlar mejor la herramienta en situaciones inesperadas 8 No la utilices sobre una escalera de tijera o soportes inestables Una posici n estable sobre una su
8. incorrecto de la herramienta 6 Cuida la herramienta para mantenerla en buenas condiciones Mant n limpia la herramienta Una herramienta con el mantenimiento adecuado corre menos riesgo de bloquearse y es m s f cil de controlar 7 Guarda las herramientas fuera del alcance de los ni os y otras personas que no sepan como utilizarlas Las herramientas son peligrosas en manos de usuarios que no saben como utilizarlas 8 Comprueba el funcionamiento de la herramienta antes de usarla 9 No fuerces la herramienta Utiliza la herramienta correcta seg n la aplicaci n La herramienta correcta realizar el trabajo mejor y con m s seguridad a la velocidad para la cual est dise ada 10 Usa abrazaderas u otra forma pr ctica para asegurar y sujetar la pieza de trabajo a una plataforma estable Sostener la herramienta con la mano o apoyarla contra el cuerpo no ofrece la estabilidad adecuada y puede causar p rdida de control HUSKYTOOLS COM Para obtener asistencia por favor llama al 1 888 43 HUSKY Informac n de Seguridad Continuaci n USO Y CUIDADO DE LA HERRAMIENTA CONTINUACON 11 Mant n la herramienta y el mango secos limpios y libres de aceite o grasa Usa siempre un pa o limpio para la limpieza Nunca uses l quido de freno gasolina productos a base de petr leo ni solventes para limpiar la herramienta 12 No utilices la herramienta como martillo 13 No utilices esta herramienta de tal manera que los fijadores se
9. aditivos puesto que estos Lubricantes causar n el desgaste acelerado de los sellos y amortiguadores de la herramienta lo que resultar en el mal funcionamiento de la misma y elevar la frecuencia del mantenimiento O Despu s de agregar el aceite haga funcionar la herramienta por un breve periodo Limpie el exceso de aceite de la salida de la cubierta Mantenimiento Continuaci n PRECAUCI N La lubricaci n excesiva puede da ar la superficie de trabajo Es responsabilidad del propietario lubricar de forma adecuada El incumplimiento de dicha tarea reducir significativamente la vida til de la herramienta y anular la garant a PRECAUCI N Lubrica la herramienta nicamente con los lubricantes especificados Limpieza Evite utilizar solventes para limpiar las piezas de pl stico La mayor a de los pl sticos tienden a da arse con los distintos tipos de solventes comerciales Utilice pa os limpios para eliminar la suciedad el polvo el aceite la grasa etc ADVERTENCIA No permita nunca que l quidos para frenos gasolina productos a base de petr leo aceites penetrantes etc entren en contacto con las piezas pl sticas Los qu micos pueden da ar debilitar o destruir el pl stico lo que puede causar lesiones personales graves Operaci n en climas fr os Si utiliza la herramienta en clima fr o con temperaturas cercanas o inferiores a los cero grados Celsius l
10. anti dust cap to cover the air connector when the tool is not in use 11 Lubrication Frequent but not excessive lubrication is required for best performance Oil for the tool added through the air line connection add will lubricate the internal parts Do not detergent oil or additives as these lubricants will cause accelerated wear to the seals and bumpers in the tool resulting in poor tool performance and frequent tool maintenance HUSKYTOOLS COM Please contact 1 888 43 HUSKY for further assistance Maintenance Continued O Disconnect the air supply from the tool to add lubricant O Turn the tool so the air inlet is facing up Place 2 3 drops of pneumatic fastening tool oil into the air inlet Do not use detergent oils oil additives or air tool oils Do not use detergent oil or additives as these lubricants will cause accelerated wear to the seals and bumpers in the tool resulting in poor tool performance and frequent tool maintenance O After adding oil run the tool briefly Wipe off any excess oil from the cap exhaust CAUTION Lubricate the tool only with specified lubricants CAUTION The work surface can become damaged by i excessive lubrication Proper lubrication is the owners responsibility Failure to lubricate the tool properly will dramatically shorten the life of the tool and void your warranty Cleaning Avoid using solvents when cleaning plastic parts
11. dirijan hacia cualquier otra cosa que no sea la pieza de trabajo 14 Nunca utilice gasolina ni ning n otro l quido inflamable para limpiar la herramienta Nunca utilice la herramienta en presencia de l quidos o gases inflamables Los vapores podr an encenderse por una chispa y causar una explosi n que podr a provocar lesiones personales graves o la muerte 15 Siempre fije la manguera con un conector o acoplador de manguera sobre o cerca de la herramienta de forma tal que todo el aire comprimido en la herramienta se descargue al momento en que el conector o el acoplador de la manguera est n desconectados No utilice una v lvula de control ni ning n otro conector que permita que el aire permanezca en la herramienta en caso contrario podr an ocurrir lesiones personales graves o la muerte 16 Nunca coloque las manos ni otra parte del cuerpo en el rea de descarga de sujetadores de la herramienta La herramienta podr a lanzar un sujetador y provocar lesiones personales graves o la muerte 17 Nunca transporte la herramienta de la manguera de aire comprimido ni jale la manguera para mover la herramienta o un compresor Mantenga las mangueras alejadas del calor el aceite y los bordes filosos Reemplace las mangueras da adas o desgastadas en caso contrario podr an ocurrir lesiones personales o da os en la herramienta 18 Siempre d por sentado que la herramienta contiene sujetadores Considere la herramienta como un implemento de
12. lt YHUSKY Preguntas problemas o piezas faltantes Antes de regresar a la tienda llama al Servicio al Cliente de Husky de lunes a viernes entre 8 a m y 6 p m hora del Eete de EE UU 1 888 43 HUSKY HUSKYTOOLS COM Guarde este manual para futuras consultas REF IMH300401AV E S 09 14 USE AND CARE GUIDE 3 IN 1 FLOORING NAILER FOR STAPLES T CLEATS AND L CLEATS Question Problems missing parts Before returning to the store call Husky Customer Service 8 a m 6 p m EST Monday Friday 1 888 43 HUSKY HUSKYTOOLS COM THANK YOU We appreciate the trust and confidence you have placed in Husky through the purchase of this pneumatic nailer We strive to continually create quality products designated to enhance your home Visit us online to see our full line of products available for your home improvement needs Thanks you for choosing Husky Table of Contents Table of contents 2 2 Safety information 3 SYMDOIS 0 none e ene n 3 Work Af Ga n2n nnn none nen nen nner nnn 3 Personal safety 3 Tool use and care 4 Tool service 5 Ail SOUTO 5 Operation 20 ene n nnn wenn nn nnn nena nen nen ne nee 5 Air supply and connections
13. sujetadores no identificados por el fabricante de la lesiones a las personas o da os en la herramienta cuando se usan con ella A c mo cambiar la placa base La herramienta viene equipada con una placa base D de 3 4 1 9 cm preinstalada de f brica Tambi n incluye una placa base adicional no instalada de 5 8 1 58cm y 1 2 1 27cm Para cambiar la placa O Desconecte la herramienta de la fuente de aire O Vac e el cargador completamente O Dispare la herramienta hacia un trozo de madera que no utilice para asegurarse de que no haya aire comprimido o sujetadores en la herramienta o Coloque la herramienta de lado para ver los cuatro tornillos E O Retire los cuatro tornillos E y luego retire la placa base O Alinee los cuatro orificios de los tornillos en la placa base de repuesto con los cuatro orificios de montaje roscados O Usando los cuatro tornillos que retiro fije la placa base de repuesto a la herramienta O Aseg rese de haber instalado la placa base correcta disparando la herramienta hacia un trozo de madera que no utilice y verificando la colocaci n adecuada del sujetador 25Sp 5 C mo ajustar la pata frontal La herramienta viene equipada con una pata frontal ajustable la que se puede ajustar para pisos de madera de 3 4 1 9cm a 5 8 1 58cm Esta herramienta se env a ajustada para pisos de madera de 3 4 1 9cm Para ajustar la pata frontal F O Desconecte
14. tool into a piece of scrap wood or flooring to make sure that it s incapable of firing any fasteners O Set the tool on its side to expose the two bolts G and two small plates H under the screws O Removed these nose bolts G and two small plate H Three nose bolts L can be seen after removing the front foot F O Remove three nose bolts L and slide the driver guide M outto expose the jammed fastener O Remove jammed fastener using plier or a screwdriver if required O Replace the driver guide M and nose bolts L OU Replace the front foot F plate H and bolts G O Reload the tool with fasteners then reconnect the air source to the tool O Press the drive guide M against a piece of wood and test fire the fasteners several times to check for proper operation If the tool is properly firing you may continue using the tool If the tool fails to perform properly immediately discontinue use and have the tool repaired by a qualified service technician magazine before clearing a jam A WARNING Make sure there is no fastener in the Driver guide M Maintenance WARNING Any time inspection maintenance and cleaning are done O Disconnect the tool from the air source O Empty the magazine completely Anti dust cap Each tool is packed with an anti dust cap on the air connector check it after unpacking Keep the
15. trabajo y no juegue con ella 19 Siempre mantenga a las dem s personas a una distancia segura del lugar de trabajo en caso se produzcan descargas accidentales de sujetadores No apunte la herramienta hacia usted u otra persona aun cuando no contenga sujetadores La activaci n accidental de la herramienta podr a provocar lesiones personales graves ola muerte 20Sp 20 No deje caer ni lance la herramienta Ya que esto podria ocasionar da os en la herramienta y causar que la misma ya no sea utilizable o segura Si la herramienta ha sufrido ca das o ha sido lanzada exam nela atentamente y revise si hay piezas dobladas rajadas o rotas y si hay fuga de aire comprimido NO PROSIGA y rep rela antes de usarla en caso contrario podr an ocurrir lesiones graves 21 Evite usar la herramienta cuando el cargador est vac o Ya que esto puede producir desgaste acelerado en la herramienta 22 Limpie y revise todas las mangueras yconectores de suministro de aire comprimido antes de conectar la herramienta a un suministro de aire comprimido Reemplace las mangueras y conectores da ados o desgastados de lo contrario el rendimiento o la durabilidad de la herramienta podr an verse reducidos 23 No utilices la herramienta si pierde aire o no funciona correctamente 24 No utilices la herramienta si no tiene una etiqueta de advertencia legible 25 Siempre sujeta la herramienta por el mango Nunca la sujetes por la manguera de aire Infor
16. 29 Conexi n recomendada 30 Soluci n de problemas 31 GRACIAS POR TU COM PRA Apreciamos la confianza que has depositado en Husky al comprar este clavadora de neum tico 17Sp HUSKYTOOLS COM Nos esforzamos para continuamente crear productos de calidad dise ados para tu hogar Vis tanos por Internet para ver nuestra Para obtener asistencia por favor llama al 1 888 43 HUSKY linea completa de propductos disponibles para tus necesidades de mejoras en el hogar Gracias por elegir Husky Informac n de Seguridad ADVERTENCIA Para evitar lesiones personales graves no intentes usar este producto hasta haber le do y comprendido el manual por completo Guarda este manual y cons ltalo con frecuencia para un funcionamiento seguro y para instruir a otros usuarios de esta herramienta A ADVERTENCIA Cuando se usen herramientas siempre se deber n seguir precauciones b sicas incluyendo las siguientes A S MBOLOS Lea el manual del operador de Para reducir el riesgo gt de lesiones el usuario debe leer y entender el manual del operador antes de usar este producto El riesgo a la audici n Siempre use protecci n para los o dos cuando se utiliza este tool Failure lo contrario podr a resultar en la p rdida de audici n e Protecci n de los ojos Use siempre gafas de seguridad gafas de seguridad con prot
17. A No conecte a una compresora de aire que pueda exceder los 13 79 bar La herramienta podr a quemarse y causar lesiones regulador falle o de 10 34 bar el que sea mayor Use mangueras de aire comprimido de 3 8 9 5mm para distancias de hasta 15 24 m y use un acoplador de conexi n r pida de 3 8 9 5mm en la manguera de aire comprimido O Use un regulador de presi n en el compresor con una presi n de trabajo de O a 8 62 bar Se necesita un regulador de presi n que controle la presi n de trabajo de la herramienta entre 4 83 y 7 93 bar Acople Manguera de Conector r pido aire comprimido r pido oe DE Acople r pido 30Sp Lubricador Filtro 4 Compresor 4 a i Regulador Soluci n de problemas i ADVERTENCIA Deje de utilizar inmediatamente la herramienta si se presenta alguno de los problemas descritos a continuaci n de lo contrario podr an ocurrir lesiones personales graves Cualquier reparaci n o reemplazo debe llevarse a cabo por un t cnico calificado o un centro de servicio autorizado Problema Causa posible Acciones correctivas Hay una filtraci n de aire en O Los tornillos est n sueltos O Apriete los tornillos la tapa O Hay juntas t ricas o sellos da ados o O Instale el kit de repuesto desgastados Falta potencia El ciclo es O La herramienta est muy seca O A ada 2 6 3 gotas de lubricante en el lento O La presi n de aire es de
18. A sujetador atascado Pernos con nariz L Gu a de disparo M HUSKYTOOLS COM Para obtener asistencia por favor llama al 1 888 43 HUSKY Mantenimiento ADVERTENCIA Cada vez que realice una inspecci n mantenimiento o limpieza O Desconecte la herramienta de la fuente de aire O Vacie el cargador completamente Antipolvo casquillo Todas las herramientas vienen con una tapa antipolvo para el conector de aire Rev sela despu s de desembalarla Mantenga la tapa antipolvo puesta sobre el conector de aire cuando la herramienta no est en uso para evitar que entren residuos en la herramienta Lubricaci n Frecuente pero la lubricaci n es necesaria para un mejor rendimiento luego de periodos de uso prolongados Si se agrega aceite a la herramienta a trav s de la conexi n de la l nea de aire se lubricar n las piezas internas No utilices aceite detergente ni aditivos puesto que estos lubricantes causar n el desgaste acelerado de los sellos y amortiguadores de la herramienta lo que resultar en el mal funcionamiento de la misma y elevar la frecuencia del mantenimiento O Desconecta la herramienta de la fuente de aire a agregue lubricantes para herramientas O Gire la herramienta de forma tal que la entrada de aire d hacia arriba Coloque 2 a 3 gotas deaceite neum tico de la herramienta de la cerradura en la entrada de aire No utilices aceite detergente ni
19. NG To avoid serious personal injury do not attempt to use this product until you read the manual manual and review frequently for continuing safe operation and instructing others who may use this tool A WARNING When using tools basic precautions should always be followed including the following SYMBOLS Read operators manual To reduce the risk of injury B user must read and understand operator s manual before using this product using this tool Failure to do so may result in hearing loss O Risk to hearing Always wear ear protection when ji glasses with side shields or a full face shield when operating this product Eye protection Always wear safety goggles safety Risk of serious personal injury Never place hands Fed or any other body parts in the fastener discharge area of the nailer the tool might eject a fastener and could result in death or serious personal injury WORK AREA SAFETY 1 2 4 Keep the work area clean and well lighted Cluttered benches and dark areas increase the risks of accidents Do not operate the tool in explosive atmospheres such as in the presence of flammable liquids gases or dust The tool creates a spark which may ignite flammable liquids gases or dust Keep bystanders children and others away while operating the tool Distractions could result in improper use and cause injury Avoid unintentional misfires Always use
20. Provides increased protection from marring when working with a finished flooring surface O Durable construction O Light weight and durably constructed of high strength aluminum and heat treated steel parts Fiberglass mallet with rubber head included Operation Loading cleat nails WARNING The tool may fire when it is first connected to the air resource Always connect the tool to the air source before loading fasteners to prevent injury from unintended cycling Pull the pusher A back to the end of magazine Lock the pusher in the place by using the Lock button C Then pull the magazine side shelter B back Place a full clip of desired fasteners into the magazine from the side Up to 100 cleat nails can be loaded into the magazine Note that when loading the L cleat nails the side with the L head should be in the left of the magazine side shelter B Press the lock button C then the pusher A set back to make the magazine side shelter B down back 2 Loading staples WARNING The tool may fire when it is first connected to the air resource Always connect the tool to the air source before loading fasteners to prevent injury from unintended cycling O O O Pull the pusher A back to the end of magazine Lock the pusher in the place by using the lock button C Then pull the magazine side shelter B back Place a full clip of 1 2 in crown staples in the magazine f
21. a fuente de aire A Conecta siempre la herramienta a la fuente de aire antes de cargar los fijadores para evitar lesiones causadas por ciclos accidentales O Jale la palanca A hacia el extremo del cargador Asegure la palanca en la posici n usando el bot n de bloqueo C Luego jale hacia atr s el seguro lateral del cargador B Coloque una carga completa de los sujetadores deseados por el lado Se pueden cargar hasta 100 listones en el cargador Tenga en cuenta que cuando cargue listones en L el lado con la cabeza en L debe estar a la izquierda del seguro lateral del cargador B Presione el bot n de bloqueo C La palanca A retroceder y har que el seguro lateral del cargador B tambi n retroceda 2 C mo cargar grapas ADVERTENCIA La herramienta puede dispararse al ser conectada por primera vez a la fuente de aire A Conecta siempre la herramienta a la fuente de aire antes de cargar los fijadores para evitar lesiones causadas por ciclos accidentales 24Sp O O bloqueo C Luego jale hacia atr s el seguro lateral del cargador B Coloque una carga completa de grapas de corona de 1 27cm por la parte superior del cargador Se pueden cargar hasta 90pzas listones en la herramienta Presione el bot n de bloqueo C La palanca retroceder A y har que el seguro lateral del cargador B tambi n retroceda Seguro lateral del cargador B Bot n de bloqueo C A
22. a humedad en la l nea de aire podr a congelarse e inutilizar la herramienta Recomendamos usar un lubricante para herramientas neum ticas o un anticongelante permanente etilenglicol como lubricante para clima fr o PRECAUCI N No almacene las herramientas en un entorno de clima fr o para evitar que se forme escarcha y o hielo en las v lvulas y mecanismos de funcionamiento de las herramientas ya que esto podr a inutilizarlas 29Sp HUSKYTOOLS COM Para obtener asistencia por favor llama al 1 888 43 HUSKY Conexi n recomendada O El compresor de aire debe ser capaz de mantener un m nimo de 4 83 bar mientras la herramienta est en uso Un suministro inadecuado de aire puede causar una p rdida de potencia y un clavado desigual Se puede usar un lubricador para proporcionar PRECAUCI N La compresora de aire debe ser capaz de mantener un m nimo de 4 83 bar cuando la herramienta est en uso Un suministro inadecuado de aire puede causar el corte del suministro de electricidad y un disparo ineficaz circulaci n de aceite en toda la herramienta Se puede usar un filtro para retirar las impurezas l quidas y s lidas las que pueden oxidar piezas internas de la herramienta o hacer que stas se apelmacen O Siempre use mangueras de aire comprimido con una clasificaci n de presi n de trabajo igual o superior a la presi n de la fuente de alimentaci n en caso que el A ADVERTENCI
23. a sujetadores en el cargador antes de ajustar la pata frontal 6 como configurar la presi n de aire O La cantidad de presi n de aire requerida depender del tama o de los sujetadores y del material de la pieza de trabajo O Comience a probar la profundidad de disparo disparando un sujetador de prueba en el mismo tipo de material de la pieza de trabajo que ocupar O Dispare un sujetador de prueba con la presi n de aire configurada entre 6 21 6 55 bar O Incremente o reduzca la presi n del aire hasta encontrar la configuraci n m nima requerida para obtener resultados ptimos 26Sp J C mo usar la herramienta O Conecte la herramienta a la fuente de aire Encienda su compresor y verifique la presi n asegur ndose de que est configurada entre 4 83 7 93 bar No exceda la presi n m xima de 7 93 bar Sostenga el agarre manual J firmemente y presione la pata frontal D en la superficie de trabajo Aseg rese de que la placa est sobre el lugar donde desea colocar el sujetador Presione hacia abajo con fuerza para que la pata frontal entre firmemente en contacto con la superficie de trabajo Luego usando el mazo incluido con la herramienta golpee la tapa del martillo K firmemente para disparar el sujetador en la superficie de trabajo Levante la herramienta de la superficie de trabajo Repita este proceso hasta que termine el trabajo O Una vez que haya terminado aseg rese de guardar la herramienta e
24. arant as impl citas incluyendo garant as de comercializaci n o adecuaci n para un prop sito particular Todas las garant as impl citas incluyendo garant as de comercializaci n o adecuaci n para un prop sito particular que no pueden ser excluidas bajo la ley estal est n limitadas a un per odo de dos a os a partir de la fecha de compra HUSKY no es responsable por da os directos o indirectos incidentales especiales o consecuenciales Si este clavadora de neum tico es usado con fines comerciales esta garant a ser a solamente v lida por noventa 90 d as a partir de la fecha de compra Algunos estados no permiten limitaciones en la duraci n de una garant a impl cita y o no permiten la exclusi n o limitaci n de da os dirctos o indirectos por lo que las limitaciones previamente enunciadas pueden no aplicarse a su caso Esta garant a le otorga derechos legales espec ficos y usted puede tambi n tener otros derechos que var an seg n el estado 22Sp Desempacar 1 Esta herramienta se ha enviado completamente ensamblada ADVERTENCIA Si falta alguna pieza no utilices esta 2 Reti id d telah ienta vI ios d herramienta hasta reemplazarla De no seguir esta ea CAME MEME IOS aEES5OnOS Oe advertencia pueden producirse lesiones graves ja 3 Inspecciona la herramienta cuidadosamente para asegurarte de que no haya ocurrido ninguna rotura ni da o durante el env o 4 No deseches el material de empaque hasta que hay
25. as inspeccionado cuidadosamente y utilizado satisfactoriamente la herramienta 5 Si alguna pieza est da ada o falta llama al 1 888 43 HUSKY Especificaciones a Entrada de aire NPT de 6 35 mm O Capacidad del cargador Clavos Tipo T y L 100 piezas Grapas 90 piezas Peso de la herramienta 4 83 kgs O Presi n m xima 7 93 bar O Presi n de funcionamiento 4 83 7 93 bar O Rango de tama o del pasador 38mm 50mm ADVERTENCIA No intentes modificar esta herramienta o construir accesorios no recomendados para la misma Tales modificaciones o cambios son considerados un mal uso y pueden resultar en condiciones peligrosas que a su vez pueden posiblemente causar lesiones Clavos Tipo T Clavos Tipo L Grapas 7 32 5 8mm 9 32 7 2mm 1 2 12 7mm B E 7A 1 1 2 38mm 1 1 2 38mm 1 1 2 38mm 1 3 4 45mm 3 4 45mm 1 3 4 45mm 2 50mm 50mm 50mm Calibre 16 Calibre 16 Calibre 15 1 2 0 075 X 0 063 1 9X 1 6mm Compatible con grapas de 12 7mm y Clavos Tipo en T y L de marcas gen ricas 23Sp HUSKYTOOLS COM Para obtener asistencia por favor llama al 1 888 43 HUSKY Operaci n Continuaci n Caracter sticas O Revolucionario dise o 3en 1 Para usar con grapas y listones enT yL ADVERTENCIA Desconecte la herramienta de la fuente de aire cada vez que cambie la placa base Aseg rese de que no haya sujetado
26. caution to avoid accidentally firing Do not point towards yourself or anyone whether it contains fasteners or not PERSONAL SAFETY WARNING Instructions pertaining to a risk of fire electric shock or injury to persons WARNING This product or its power cord may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling Do not nail on top of another nail This can cause deflected and hit someone or cause the tool to react and result in a risk of injury to persons Always wear eye protection Operator and others in the work area should always wear ANSI approved Safety goggles with side shields Eye protection is used to guard against flying fasteners and debris which may cause severe eye injury Always wear hearing protection when using the tool Prolonged exposure to high intensity noise may cause hearing loss Use safety equipment A dust mask non skid safety shoes and a hard hat must be used for the applicable conditions Wear a full face shield if you are producing metal filings or wood chips Dress properly Do not wear loose clothing or jewelry Contain long hair Keep your hair clothing and gloves away from moving parts Loose clothes jewelry or long hair can be caught in moving parts 6 Stay alert watch what you are doing and use common sense when operating a power tool Do not use tool while tired or
27. cessories that are identified by the manufacturer for the specific tool model 2 When servicing a tool use of unauthorized parts of failure of following maintenance instructions may create a risk of injury 3 Use only the lubricants supplied with the tool or specified by the manufacturer 4 Tool service must be performed only by qualified repair personnel AIR SOURCE 1 Never connect to an air source that is capable of exceeding 200 psi Over pressurizing the tool can result in bursting abnormal operation breakage of the tool or serious injury to persons Use only clean dry regulated compressed air at the rated pressure or within the rated pressure range as marked on the tool Always verify prior to using the tool that the air source has been adjusted to the rated air pressure or within the rated air pressure range 2 Never use oxygen carbon dioxide combustible gases or any bottled gas as an air source for the tool Such gases are capable of explosion and serious injury to person OPERATION 1 Do not drive fasteners near edge of material The workpiece may split causing the fastener to ricochet injuring you or people around 2 During normal use the tool will recoil immediately after driving a fastener This is a normal function of the tool Do not attempt to prevent the recoil by holding the tool against the work Restriction to the recoil can result in a second fastener being driven from the tool Grip the handle firmly a
28. de obrar en consecuencia en el rea de descarga de los fijadores 3 Nunca apuntes la herramienta hacia las personas 4 No jale el gatillo ni presione la pieza de trabajo en contacto ya que se podr a accionar accidentalmente y posiblemente causar lesiones Garant a GARANT A LIMITADA DE DOS A OS DE CLAVADORA DE NEUM TICO DE HUSKY Esta garant a cubre defectos de fabricaci n o materiales de est clavadora de neum tico HUSKY por un periodo de dos a os desde la fecha de compra Esta garant a es espec fica a este clavadora de neum tico las garant as de otros productos HUSKY pueden variar Esta garant a se aplica s lo al comprador original y no puede transferirse Esta garant a no cubre el desgaste normal por uso o mal funcionamiento fallas o defectos que resulten del uso incorrecto abuso negligencia alteraci n modificaci n o reparaci n de un centro de servicio distinto al autorizado para reparar los clavadora de neum tico de marca HUSKY Los materiales expansibles como juntas t ricas parachoques acconadora sellos etc no est n cubiertos por esta grant a Esta garant a no se aplica si este clavadora de neum tico es usado para aplicaciones industriales o de alquiler HUSKY no garantiza representa ni promete la calidad o rendimiento de estos clavadora de neum tico distintos a los especificados en esta garant a LIMITACIONES ADICIONALES En la medida en que la ley lo permita se excluyen todas las g
29. ecci n lateral o una careta completa cuando utilice esta producto Riesgo de lesiones personales graves Nunca coloque las manos o cualquier otra parte del cuerpo en la zona de descarga del sujetador de la clavadora La herramienta puede expulsar un sujetador y puede causar la muerte o lesiones graves AREA DETRABAJ O 1 Mantenga el rea de trabajo limpia y bien iluminada Los bancos de trabajo desordenados y las reas oscuras aumentan el riesgo de accidentes 2 No utilice la herramienta en atm sferas en las que exista riesgo de explosi n como por ejemplo en presencia de l quidos inflamables gases o polvo La herramienta produce una chispa que podr a encender l quidos inflamables gases o polvo 3 Mantenga a los transe ntes ni os y a otras personas alejadas cuando est utilizando la herramienta Las distracciones podr an resultar en el uso inapropiado y causar lesiones 4 Evite los disparos accidentales Siempre tenga precauci n para evitar disparos accidentales No apunte la herramienta hacia usted u otra persona aun cuando no contenga sujetadores 18Sp SEGURIDAD PERSONAL A A 1 No clave sobre otro clavo Esto puede causar que el clavo se desv e y alcance a alguien o que la herramienta reaccione de alguna manera y lesione a alguien 2 Usa siempre protecci n para los ojos El operador y las otras personas en el rea de trabajo deben usar siempre gafas de seguridad con protectores laterales
30. ect air source O Before unloading or making adjustments O When maintaining the tool O When clearing a jam When tool is not in use When moving to a different work area Such precautionary measures reduce the risk of injury to persons O O HUSKYTOOLS COM Please contact 1 888 43 HUSKY for further assistance Safety Information Continued LOADING THE TOOL WARNING The warnings and precautions discussed 1 Do not load the tool with fasteners when any one of the 4 an above cannot cover all possible conditions and operating controls is activated situations that may occur It must be understood by 2 Never place a hand or any part of body in the fastener the user that common sense and caution are discharge area of the tool factors which cannot be built into this product but 3 Never point tool at anyone must be supplied by the user Warranty HUSKY PNEUMATIC NAILER LIMITED TWO YEAR WARRANTY This warranty covers defects in workmanship or materials in this HUSKY pneumatic nailer for the two year period from the date of purchase This warranty is specific to this pneumatic nailer Warranties for other HUSKY products may vary This warranty applies only to the original retail purchaser and may not be transferred This warranty does not cover normal wear and tear or any malfunction failure or defect resulting from misuse abuse neglect alteration modification or repair by other than a service center aut
31. horized to repair HUSKY branded air nailer Expendable materials such as O rings bumpers driver blades seals etc are not covered by this warranty This warranty does not apply to pneumatic nailer used in industrial application or for rental purposes HUSKY makes no warranties representations or promises as to the quality or performance of its pneumatic nailer other than those specifically stated in this warranty ADDITIONAL LIMITATIONS To the extent permitted by applicable law all implied warranties including warranties of merchantability or fitness for a particular purpose are disclaimed Any implied warranties including warranties of merchantability or fitness for a particular purpose that can not be disclaimed under state law are limited to two years from the date of purchase HUSKY is not responsible for direct indirect incidental special or consequential damages If this pneumatic nailer is used for commercial purposes the warranty will apply for ninety 90 days from the date of purchase Some states do not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Unpacking 1 This tool kithas been shipped completely assembled box 3 Inspect the tool carefully to make sure no brea
32. ion The correct tool will do the job better and safer at the rate for which it is designed 10 Use clamps or another practical way to secure and support the workpiece to a stable platform Holding a tool by hand or against the body is unstable and may lead to loss of control 11 Keep the tool and its handle dry clean and free from oil and grease Always use a clean cloth when cleaning Never use brake fluids gasoline petroleum based products or any strong solvents to clean your tool 12 Do not use the tool as a hammer 13 Never use this tool in a manner that could cause a fastener to be directed toward anything other than the workpiece 14 Never use gasoline or other flammable liquids to clean the tool Never use the tool in the presence of flammable liquids or gases Vapors could ignite by a spark and cause an explosion which will result in death or serious personal injury 15 Always fit the tool with a fitting or hose coupling on or near the tool in such a manner that all compressed air in the tool is discharged at the time the fitting or hose coupling is disconnected Do not use a check valve or any other fitting which allows air to remain in the tool Death or serious personal injury could occur 16 Never place hands or any other body parts in the fastener discharge area of the tool The tool might eject a fastener and could result in death or serious personal injury 17 Never carry the tool by the air hose or pull the hose t
33. kage or 2 Carefully remove the tool and any accessories from the A WARNING If any parts are missing do not operate the tool until the missing parts are replaced Failure to do so could result in possible serious personal injury damage occurred during shipping 4 Do not discard the packing material until you have carefully inspected and satisfactorily operated the tool 1 888 43 HUSKY 5 If any parts are damaged or missing please call WARNING Do not attempt to modify the tool or create accessories not recommended for use with the tool Any such alteration or modification is misuse and could result in hazardous condition leading to possible serious personal injury Specifications O Air inlet 1 4 inch NPT O Magazine capacity L Cleat amp T Cleat 100pcs Staples 90pcs O Weight 10 62 Ibs O Maximum pressure 115 psi O Pressure range 70 psi 115 psi O Pin size range 1 1 2 inch to 2 inch T Cleats L Cleats Staples 7 32 5 8mm 9 32 7 2mm 1 2 12 7mm 38mm 1 1 2 38mm 1 1 2 38mm 3 4 45mm 3 4 1 3 4 45mm 2 50mm 16 ec a 16 AS 15 1 2 Gauge 0 075 X 0 063 1 9X 1 6 mm Compatible With Generic Brands 1 2 Crown Staples T Cleats L Cleats 7 HUSKYTOOLS COM Please contact 1 888 43 HUSKY for further assistance Features O Revolutionary 3 in 1 design For use with Staples T Cleats and L Cleats Non marring design
34. l sujetador atascado siga los siguientes pasos O Desconecte la herramienta de la fuente de aire O Vac e el cargador Aseg rese de retirar todos los sujetadores O Intente disparar a un trozo de madera o piso que no utilice para asegurarse de que no puede disparar ning n sujetador O Coloque la herramienta de lado para ver los dos pernos G y las dos placas peque as H debajo de los tornillos O Retire los pernos G y las dos placas peque as H Ver tres pernos con nariz L despu s de retirar la pata frontal F O Retire los tres pernos con nariz L y deslice la gu a de disparo M hacia fuera para ver el sujetador atascado O Retire el sujetador atascado usando unas pinzas o un destornillador si es necesario O Vuelva a colocar la gu a de disparo M y los pernos con nariz L 27Sp Vuelva a colocar la pata frontal F la placa H y los pernos G en su lugar Recargue la herramienta con sujetadores y uego vuelva a _ conectarla a la fuente de aire Presione la gu a de disparo M contra un trozo de madera y dispare varios sujetadores para asegurarse de que la herramienta funciona correctamente Si la herramienta dispara de forma adecuada puede seguir us ndola Si la herramienta no funciona correctamente suspenda su uso de inmediato y haga que un t cnico calificado la repare sujetadores en el cargador antes de retirar un ADVERTENCIA Aseg rese de que no haya
35. la herramienta de la fuente de aire O Vac e el cargador completamente O Dispare la herramienta hacia un trozo de madera que no utilice para asegurarse de que no haya aire comprimido o sujetadores en la herramienta Coloque la herramienta de lado para ver los dos pernos G y las dos placas peque as H O Afloje los pernos G y las dos placas peque as H para mover la pata frontal F en el espacio de la ranura de ajuste I O Ajuste la pata frontal F en la posici n adecuada de acuerdo al grosor de los pisos de madera y luego asegure los pernos G y las dos placas peque as H firmemente O Aseg rese de que la pata frontal sea adecuada para el piso de madera disparando la herramienta hacia un trozo de piso que no utilice y verificando la colocaci n adecuada del sujetador HUSKYTOOLS COM Para obtener asistencia por favor llama al 1 888 43 HUSKY Operaci n Continuaci n Pernos G Pata frontal F Placa peque a H TT R SOZ Ai HHH H Ranura de ajuste 1 Ranura de ajuste 1 ADVERTENCIA Desconecte la herramienta de la fuente de aire cada vez que ajuste la pata frontal Aseg rese de que no hay
36. limita al ox geno o a gases combustibles como fuente de alimentaci n Use nicamente aire comprimido filtrado lubricado y regulado El uso de gas reactivo en lugar de aire comprimido puede hacer que la herramienta explote lo cual producir a lesiones personales graves o la muerte 3 Use nicamente una fuente de aire comprimido de presi n regulada para limitar la presi n de aire suministrada a la herramienta La presi n regulada no debe superar los 7 93 bar Si el regulador falla la presi n enviada a la herramienta no debe superar los 13 79 bar 4 Desconecta siempre la fuente de aire O Antes de descargar o realizar ajustes O Al realizar el mantenimiento de la herramienta O Al desatascarla O Cuando la herramienta no est en uso O Al desplazarse a otra rea de trabajo Dichas medidas de precaucion reduciran el riesgo de lesiones a personas HUSKYTOOLS COM Para obtener asistencia por favor llama al 1 888 43 HUSKY Informac n de Seguridad Continuaci n CARGAR LA HERRAMIENTA 1 No cargues la herramienta con fijadores si alguno de los controles operativos esta activado 2 Nunca coloques la mano ni ninguna otra parte del cuerpo ADVERTENCIA Las advertencias y precauciones mencionadas anteriormente no abarcan todas las condiciones y situaciones posibles Es perfectamente comprensible que no podemos fabricar el sentido com n y la precauci n como partes de ning n producto el usuario es el responsable
37. mac n de Seguridad Continuaci n REPARACI N DE LA HERRAMIENTA 1 Usa nicamente accesorios identificados por el fabricante para ese modelo espec fico de herramienta 2 Al mantener una herramienta la utilizaci n de piezas no autorizadas o el incumplimiento de las instrucciones de mantenimiento pueden aumentar el riesgo de lesiones 3 Usa nicamente los lubricantes provistos con la herramienta o especificados por el fabricante 4 La reparaci n de la herramienta debe ser realizada nicamente por personal calificado FUENTE DEL AIRE 1 Nunca conecte a una fuente de aire que pueda superar los 13 79 bar El exceso de presi n de la herramienta es capaz de ocasionar una explosi n funcionamiento anormal rotura de la herramienta o lesiones graves a personas Utilice s lo aire limpio y seco y regulado a la presi n nominal o dentro del rango de presi n indicado en la herramienta Verifique siempre antes de utilizar la herramienta que la fuente de aire se ha ajustado a la presi n de aire especificada o dentro del rango nominal de presi n de aire 2 Nunca utilice ox geno di xido de carbono gases combustibles u otros gases embotellados como fuente de aire para la herramienta Dichos gases pueden explotar y causar lesiones graves a las personas FUNCIONAMIENTO 1 No coloques fijadores cerca del borde del material La pieza de trabajo puede partirse y hacer que el fijador rebote y te da e ati o a las personas alrededor
38. masiado baja conector de aire O La salida de aire est bloqueada O Aseg rese de que la compresora de aire este ajulstada entre los 4 83 7 93 bar O Limpie la canaleta de la salida de aire La herramienta no dispara O El resorte del disparador est da ado O Cambie el resorte los sujetadores O No est usando sujetadores del tama o O Use grapas de corona de 12 7mm 1 2 apropiado o sujetadores listones en T y L de 38mm 1 1 2 a 50mm 2 Los sujetadores se atascan O La canaleta de disparo est desgastada O Repare la canaleta de disparo frecuentemente en la O El pist n est roto o desgastado O Cambie el pist n herramienta O Los sujetadores est n torcidos O Retire los sujetadores torcidos y O El cargador est sucio O Limpie el cargador O El cargador est suelto O Apriete los tornillos O Est utilizando los sujetadores O Verifique que los sujetadores sean del incorrectos tama o apropiado 31Sp HUSKYTOOLS COM Para obtener asistencia por favor llama al 1 888 43 HUSKY
39. n un lugar limpio seco y seguro fuera del alcance de los ni os y de personas no autorizadas O O ADVERTENCIA Se debe tener extrema precauci n cuando esta herramienta est conectada a una fuente de aire Si la herramienta se cae o si la tapa del martillo K se golpea accidentalmente la herramienta disparar un sujetador pudiendo causar una LESI N PERSONAL GRAVE ADVERTENCIA Mantenga sus pies alejados de la herramienta ADVERTENCIA Antes de usar la herramienta sobre un piso pruebe la herramienta en un trozo de madera que A no utilice Ajuste la profundidad de disparo incrementando o reduciendo la presi n de aire Nunca exceda el m ximo de 7 93 bar Agarre manual J Tapa del martillo K Operaci n Continuaci n ADVERTENCIA No se debe utilizar una herramienta que funcione de forma inadecuada No accione la herramienta a menos que se encuentre bien colocada en la pieza de trabajo NOTA Aseg rese de que la tapa del martillo en la clavadora de pisos est hacia arriba antes de colocar la manguera de aire si no la clavadora puede girar Ver a continuaci n Tapa del martillo Posici n hacia abajo Tapa del martillo Posici n hacia arriba 8 Como retirar sujetadores atascados En ocasiones un sujetador puede atascarse en el mecanismo de disparo dejando la herramienta inoperante Para retirar e
40. nance AN clearing jams touching the safety yoke leaving work area or unloading the tool Such precautionary measures reduce the risk of injury to persons 1 Know this tool Read this manual carefully learn its applications and limitations as well as the specific potential hazards related to this tool 2 Use only fasteners that are recommended for your models Do not use the wrong fasteners or load the fasteners incorrectly 3 Use only accessories that are identified by the manufacturer for the specific tool model Use of unauthorized parts or failure to follow maintenance instructions may create a risk of injury 4 Use only those fasteners recommended for use with this tool Fasteners not identified for use with this tool by the tool manufacturer are able to result in a risk of injury to persons or tool damage when used in this tool 5 Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the tool s operation If damaged have the tool serviced before using Many accidents are caused by poorly maintained tools 6 Maintain tools with care Keep tools clean A properly maintained tool reduces the risk of binding and is easier to control 7 Store tools out of the reach of children and other untrained people Tools are dangerous in the hands of untrained users 8 Check operation of the tool before use 9 Do not force the tool Use the correct tool for your applicat
41. nd let the tool do the work Failure to heed this warning can result in serious personal injury 3 Do not drive fasteners on top of other fasteners or with the tool at an overly steep angle as this may cause deflection of fasteners which could cause injury 4 Do not actuate the tool unless you intend to drive a fastener into the workpiece 5 Always handle the tool with care O Respect the tool as a working implement O Never engage in horseplay O Keep others a safe distance from the tool while tool is in operation as accidental actuation may occur possibly causing injury AIR SUPPLY AND CONNECTIONS 1 The connector on the tool must not hold pressure when air supply is disconnected If an incorrect fitting is used the tool can remain charged with air after disconnecting and thus will be able to drive a fastener even after the air line is disconnected possibly causing injury 2 Do not use any type of reactive gases including but not limited to oxygen and combustible gases as a power source Use filtered lubricated regulated compressed air only Use of a reactive gas instead of compressed air may cause the tool to explode which will cause death or serious personal injury 3 Use only a pressure regulated compressed air source to limit the air pressure supplied to the tool The regulated pressure must not exceed 115 psi If the regulator fails the pressure delivered to the tool must not exceed 200 psi 4 Always disconn
42. nt HUSKYTOOLS COM Please contact 1 888 43 HUSKY for further assistance Operation Continued Front foot F Small plate H Adjust just groove l Adus groove l WARNING Disconnect the tool from the air source whenever changing the foot plate Make sure there is no fastener in the magazine before changing the foot plate 6 Setting the air pressure O The amount of air pressure required depends on the size of the fasteners and the workpiece material O Begin testing the depth of the drive by driving a test nail into the same type of workpiece material used for the actual job O Drive a test fastener with the air pressure set at 90 95 psi O Raise or lower the air pressure to find the lowest setting that will perform the job with consistent results J Operating the tool O Attach the tool to the air source Start your compressor and check the pressure making sure it is set between 70 115 psi Do not exceed the maximum115 psi O Hold the hand grip J securely and press the foot plate D to the work surface Make sure the plate is over the fastener target position O Press down hard so that the foot plate is firmly contacting the work surface Then using the mallet packed with the tool strike the hammer cap K firmly to drive the fastener into the work surface Lift the tool off the work surface
43. o move the tool or a compressor Keep hoses away from heat oil and sharp edges Replace any hose that is damaged weak or worn Personal injury or tool damage could occur 18 Always assume the tool contains fasteners Respect the tool as aworking implement no horseplay 19 Always keep others at a safe distance from the work area in case of accidental discharge of fasteners Do not point the tool toward yourself or anyone whether it contains fasteners or not Accidental triggering of the tool could result in death or serious personal injury 20 Do not drop or throw the tool Dropping or throwing the tool can result in damage that will make the tool unusable or unsafe If the tool has been dropped or thrown examine the tool closely for bent cracked or broken parts and air leaks STOP and repair before using or serious injury could occur 21 Avoid using the tool when the magazine is empty Accelerated wear on the tool may occur 22 Clean and check all air supply hoses and fittings before connecting the tool to an air supply Replace any damaged or worn hoses or fittings Tool performance or durability may be reduced 23 Do not use the tool if it leaks air or does not function properly Safety Information Continued TOOL USE AND CARE CONTINUED 24 Do not operate the tool if it does not contain a legible warning label 25 Always carry the tool by the handle Never carry the tool by the air hose TOOL SERVICE 1 Use only ac
44. os cong nitos y otros da os en el aparato reproductivo 19Sp USO Y CUIDADO DE LA HERRAMIENTA ADVERTENCIA Disconecten la grapadora de el aire antes de ajustes mantenimiento tacto del yugo de seguridad quitando grapas quebradas y terminado el proyecto Esto va ayudar para que nadien tenga un A dano 1 Inf rmate sobre la herramienta Lee el manual con cuidado aprende sobre sus aplicaciones y limitaciones como tambi n sobre los riesgos espec ficos y potenciales relacionados con la herramienta 2 Utilice s lo los sujetadores recomendados para cada modelo No utilice sujetadores inadecuados ni cargue los sujetadores de forma incorrecta 3 Usa nicamente accesorios identificados por el fabricante para ese modelo espec fico de herramienta La utilizaci n de piezas no autorizadas o el incumplimiento de las instrucciones de mantenimiento pueden aumentar el riesgo de lesiones 4 Use solamente los sujetadores recomendados para esta herramienta Los sujetadores no identificados por el fabricante de la herramienta para usarse con la misma pueden causar lesiones a las personas o da os en la herramienta cuando se usanconella 5 Comprueba que las piezas m viles no est n desalineadas ni bloqueadas que no haya piezas da adas o cualquier otra condici n que pueda afectar el funcionamiento de la herramienta Si est da ada repara la herramienta antes de utilizarla Muchos accidentes se deben al mantenimiento
45. p to 50 ft and use a 3 8 in quick coupler on the air hose O Use a pressure regulator on the compressor with an operating pressure of 0 125 psi A pressure regulator is required to control the operating pressure of the tool between 70 psi and 115 psi Quick Coupler Air hose Quick os NX or CAUTION The air compressor must be able to maintain a minimum of 70 psi when the tool is being used An inadequate air supply can cause a loss of power and inconsistent driving which can potentially exceed 200 psi The tool may WARNING Do not connect with an air compressor A burst possibly causing injury Oiler Filter r T od Quick Regulator 765 Coupler HUSKY TOOLS COM Please contact 1 888 43 HUSKY for further assistance Troubleshooting WARNING Stop using the tool immediately if any of the following problems occur Serious personal injury could result Any repairs or replacements must be done by a qualified service person or an authorized service center Problems Possible cause s Corrective action Air leaking in head cap O Loose screw O Tighten screws O Worn or damaged o rings or seals O Install overhaul kit Lack of power O Tool is too dry o Add about 2 3 drops of lubrication Slow to cycle O Air pressure too low into the air connector l O Exhaust blocked o Make sure the air compressor is set between 70 psi and 115 psi Clean exhaust channel
46. perficie s lida permite un mejor control de la herramienta en situaciones imprevistas ADVERTENCIA Instrucciones en referencia al peligro de incendios choque electrico o lesiones personales ADVERTENCIA Este producto a su cord n el ctrico puede contener productos quimicos conocidos por el estado de California como causantes de c ncer y defectos de nacimiento u otros da os reproductiveos Lave sus manos despu s de usar Informac n de Seguridad Continuaci n SEGURIDAD PERSONAL CONTINUACI N 9 Aseg rate de que la manguera est libre de obstrucciones o trabas Las mangueras atascadas o enredadas pueden causar la p rdida del equilibrio o la estabilidad y pueden da arse y causar lesiones 10 No se extienda demasiado Mantenga un apoyo de pies y un equilibrio adecuados en todo momento Un apoyo de pies y equilibrio adecuados permiten un mejor control de la herramienta en situaciones inesperadas 11 No fije la manguera o herramienta a su cuerpo Fije la manguera a la estructura para reducir el riesgo de p rdida de equilibrio en caso que la manguera se mueva 12 Siempre d por sentado que la herramienta contiene sujetadores No apunte la herramienta hacia usted u otra persona aun cuando no contenga sujetadores 13 Lavese las manos despu s de manipularlo Este producto o su cable el ctrico pueden contener sustancias qu micas reconocidas por el estado de California como causantes de c ncer defect
47. res en el cargador antes de cambiar la placa base 3 C mo cargar listones los grapas O Dise o que no raya Brinda protecci n a las superficies acabadas de los pisos La descarga es lo opuesto a la carga Excepci n siempre desconecte la fuente de aire antes de realizar la descarga O Fabricaci n duradera Fabricaci n liviana y duradera en aluminio de alta resistencia y piezas de acero con tratamiento t rmico sujetadores antes de retirar la herramienta del servicio ADVERTENCIA Siempre descargue todos los O Incluye mazo de fibra de vidrio con cabeza de goma ADVERTENCIA La herramienta puede dispararse cuando se conecte por primera vez a una fuente de aire Siempre conecte la herramienta a la fuente de E A aire antes de cargar los sujetadores para prevenir lesiones causadas por ciclos accidentales Aseg rese siempre de que el cargador de la herramienta est vac o al comienzo de cada sesi n de trabajo antes de conectar la herramienta a la fuente de aire Operaci n ADVERTENCIA Use solamente los sujetadores Placa base recomendados para esta herramienta Los D Piso de 1 58cm Ojale la palanca A hacia el extremo del cargador Asegure la palanca en la posici n usando el bot n de 1 C mo cargar listones herramienta para usarse con la misma pueden causar ADVERTENCIA La herramienta puede dispararse al ser conectada por primera vez a l
48. romthe top You can load up the 90 pieces into the tool Press the lock button C then the pusher A sets back to make the magazine side shelter B down back Operation Continued 3 Unloading cleat nails and staples Unloading is the reverse of loading Always disconnect the air source before unloading WARNING Always unload all fasteners before removing tool from service WARNING The tool may fire when it first connected to the air source Always connect the tool to the air source before loading fasteners to prevent injury from unintended cycling Always make sure the tool s magazine is empty at the beginning of each work session before connecting to an air source WARNING Use only those fasteners recommended for use with this tool Fasteners not identified for use AN with this tool by the tool manufacturer are able to result in a risk of injury to persons or tool damage when used in this tool 4 Changing the foot plate The tool is equipped with a factory pre installed 3 4 in foot plate D And an additional uninstalled 5 8 in amp 1 2 in foot plate To change the plate O Disconnect the tool from the air source O Empty the magazine completely O Fire the tool into a piece of scrap wood to ensure there is no compressed air or fasteners left in the tool Set the tool on its side to expose the four screws E Remove the four screws E then remove the foot plate O Align
49. the four screw holes in the replacement foot plate with the four threaded mounting holes O Using the four screws you removed secure the replacement foot plate to the tool O Ensure the correct foot plate is installed by firing into a scrap piece of flooring and checking for proper fastener placement WARNING Disconnect the tool from the air source whenever changing the foot plate Make sure there is no fastener in the magazine before changing the foot plate Screws E Foot plate D 5 Adjusting the front foot The tool is equipped with an adjustable front foot can be adjusted for 3 4 in 5 8 in wood floors This tool is shipped out Set for 3 4 in wood floor To adjust the front foot F O Disconnect the tool from the air source Empty the magazine completely O Fire the tool into a piece of scrap wood to ensure There is no compressed air or fasteners left in the tool Set the tool on its side to expose the two bolts G and two small plates H Loose these two bolts G and two small plates H to ensure move the front foot F in the range of the adjust groove I Adjust the proper position of the front foot F according to the actual thickness of wood floors and then tightly lock these two bolts G and two small plates H Ensure the correct front foot set for the wood floor by firing into a scrap piece of flooring and checking for proper fastener placeme
50. under the influence of drugs alcohol or medication A moment of inattention while operating the tool may cause serious injury 7 Keep proper footing and balance at all times Proper footing and balance enables better control of the tool in unexpected situations 8 Do not use on a ladder or unstable supports Stable footing on a solid surface enables better control of the tool in unexpected situations 9 Make sure the hose is free of obstructions or snags Entangled or snarled hoses can cause loss of balance or footing and may become damaged resulting in possible injury 10 Do not overreach Keep proper footing and balance at all times Proper footing and balance enables better control of the tool in unexpected situations 11 Do not attach the hose or tool to your body Attach the hose to the structure to reduce the risk of loss of balance if the hose shifts HUSKYTOOLS COM Please contact 1 888 43 HUSKY for further assistance Safety Information Continued PERSONAL SAFETY CONTINUED 12 Always assume that the tool contains fasteners Do not point the tool toward yourself or anyone whether it contains fasteners or not 13 Wash hands after handling This product or its power cord may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm TOOL USE AND CARE WARNING Disconnect the tool from the air source before making adjustments doing tool mainte