1. WEARING PARTS Repair parts can be ordered from our website http www freemantools com HTTP WWW FREEMANTOOLS COM 1 888 669 5672 09
2. of power and inconsistent driving Do not connect with an air compressor which can potentially exceed 200psi As tool may burst possibly causing injury aid hose Quick Pcs j Air connector N connector di 3 cou TROUBLE SHOOTING SUGGESTED PROBLEMS POSSIBLE CAUSES ea righ 1 Loose screws Worn or damaged O rings or seals Air leaking near the top of the tool or in the trigger area 1 Tighten screws Install overhaul kit 1 Loose screws Worn or damaged O rings or seals Air leaking near the bottom of the tool 1 Tighten screws Install overhaul kit Tool does nothing 1 Inadequate air supply or operates sluggishly Tool is too dry Exhaust blocked Worn or damaged O rings or seals 1 Make sure the air compressor is set between 7Opsi and 100psi Add about 2 3 drops of lubrication into the air connector Clean exhaust channel Install overhaul kit 1 Fix the drive channel Replace the piston Remove the bent fasteners replace with the right fasteners Fasteners are jammed 1 Drive channel is worn in the tool frequently 2 Piston is broken or worn 3 Bent fasteners 4 Dirty magazine 5 Loose magazine Clean magazine 6 Wrong fasteners Tighten screws Verify that fasteners are the correct size A WARNING Use only Freeman Authorized Repair Parts For questions please call 1 888 669 5672 or visit our website at http www freemantools com
3. Insert a stick of fasteners into the magazine Flooring nose rail l Make sure the pointed ends of the cover C fasteners are resting on the bottom ledge of the magazine when loading Make sure the fasteners are not dirty or damaged 4 Push the magazine cover H forward until latch button pops up Regular nose cover F Latch button G Put the pin E and O ring D back Magazine rail l HTTP WWW FREEMANTOOLS COM 1 888 669 5672 05 MODEL PFBC940 REEMAN A WARNING The tool may fire when it is first connected to the air resource Always connect the tool to the air resource before loading fasteners to prevent injury from unintended cycling Always make sure the tool s magazine is empty at the beginning of each work session before connecting to an air resource A WARNING Use only the fasteners recommended for use with this tool The use of any other fasteners could result in tool malfunction leading to serious injuries A WARNING Keep the tool pointed away from yourself and others when loading fasteners Failure to do so could result in possible serious personal injury A WARNING Never load fasteners with the workpiece contact or trigger activated Doing so could result in possible serious personal injury Latch B UNLOADING FASTENERS Unloading is the reverse of loading always disconnect the air resource before unloading A WARNING Alw
4. MODEL PFBC940 ff S F 18 GA 4 IN1 MINI FLOORING _NAILER STAPLER AND BRAD NAILER STAPLER COMBO HTTP WWW FREEMANTOOLS COM e 1 888 669 5672 PRIME GLOBAL PRODUCTS INC Failure to follow warnings could result in DEATH OR SERIOUS INJURY e 1 888 669 5672 PRIME GLOBAL PRODUCTS INC SAVE THIS MANUAL FOR FUTURE REFERENCE IMF300300AV 03 10 WARNING HTTPuWWW FREEMANTOOLS COM I REEMAN MODEL PFBC940 Se eee GENERAL SAFETY RULES Pi UNPACKING P3 FEATURES P3 OPERATION ADJUSTING THE EXHAUST P4 CHANGE THE NOSE COVER P4 LOADING FASTENERS P5 UNLOADING FASTENERS P6 CLEARING JAMS P6 NO MARRING PAD P7 SETTING THE AIR PRESSURE P7 DEPTH ADJUSTMENT P7 ADJUST THE FLOORING PLATE P7 FIRING THE TOOL P8 MAINTENANCE P8 RECOMMENDED HOOKUP P9 TROUBLE SHOOTING P9 WEARING PARTS P9 A WARNING The warnings and precautions discussed in the manual cannot cover all possible conditions and situations that may occur It must be understood by the user that common sense and caution are factors which cannot be built into this product but must be supplied by the user HTTP WWW FREEMANTOOLS COM 1 888 669 5672 MODEL PFBC940 REEMAN SAVE THIS MANUAL Keep this manual for the safety warnings and precautions operating inspection maintenance Keep this manual and the receipt in a safe and dry place for future reference SYMBOLS A WARNING To avoid serious personal injury do
5. ays unload all fasteners before removing tool from service A WARNING Always disconnect the air resource before Disconnect the tool from air resource 2 Remove fasteners from the tool Failure to do so will cause the fasteners to eject from the front of the tool Pull up on the latch B and open the Flooring nose cover C Using caution not to bend or damage the driver blade using pliers or a screw driver if required to clear the jammed fastener Close the nose and latch Reconnect the tool to the air resource Reload the tool with fastener Flooring nose cover C Sy NOTE It s the same to clear the jam with the regular nose cover A WARNING Make sure there is no fastener in magazine before clearing a jam unloading CLEARING JAMS Occasionally a fastener may become jammed in the firing mechanism of the tool making the tool inoperable To remove a jammed fastener follow these steps 06 HTTP WWW FREEMANTOOLS COM A WARNING Disconnect the tool from the air source whenever clearing a jam After disconnecting the tool from the air compressor there should still be enough air pressure to fire the tool After the air hose is disconnected always fire the tool into scrap wood repeatedly to make sure all of the compressed air is expended 1 888 669 5672 MODEL PFBC940 A WARNING Disconnect the tool from the air sour
6. better and safer at the rate for which it is designed Use clamps or another practical way to secure and support the workpiece to a stable platform Holding a tool by hand or against the body is unstable and may lead to loss of control Keep the tool and its handle dry clean and free from oil and grease Always use a clean cloth when cleaning Never use brake fluids gasoline petroleum based products or any strong solvents to clean your tool Do not use the tool as a hammer Never use this tool in a manner that could cause a fastener to be directed toward anything other than the workpiece Always carry the tool by the handle Never carry the tool by the air hose Do not use the tool if it leaks air or does not function properly Do not operate the tool if it does not contain a legible warning label 02 HTTP WWW FREEMANTOOLS COM TOOL SERVICE Use only accessories that are identified by the manufacturer for the specific tool model Use of unauthorized parts or failure to follow maintenance instructions may create a risk of injury Use only the lubricants supplied with the tool or specified by the manufacturer Tool service must be performed only by qualified repair personnel OPERATION Do not drive fasteners near edge of material The workpiece may split causing the fastener or ricochet injuring you or people around Do not carry the tool from place to place holding the trigger Accid
7. ce whenever clearing a jam After disconnecting the tool from the air compressor there should still be enough air pressure to fire the tool After the air hose is disconnected always fire the tool into scrap wood repeatedly to make sure all of the compressed air is expended NO MARRING PAD A no marring pad is packed with the tool for the regular nose cover use The no marring pad attached to the nose of the tool helps prevent marring and denting when working with finished surfaces A WARNING Disconnect the tool from the air source before removing or replacing the no marring pad or replacing the no marring pad Failure to do so could result in serious personal injury SETTING THE AIR PRESSURE The amount of air pressure required depends on the size of the fasteners and the working material Begin testing the depth of drive by driving a test nail into the same type of working material used for the actual job Drive a test fastener with the air pressure set at 90 95psi Raise or lower the air pressure to find the lowest setting that will perform the job with consistent results It may be possible to achieve the desired depth with air pressure adjustments alone DEPTH ADJUSTMENT The driving depth of the fasteners are adjustable To adjust the depth use the drive depth adjustment wheel J on the tool t 2 3 Drive a test nail after each adjustment until the Disconnect the tool from air resou
8. ental discharge could result Choice of triggering method is important Check manual for triggering options During normal use the tool will recoil immediately after driving a fastener this is a normal function of the tool Do not attempt to prevent the recoil by holding the tool against the work Restriction to the recoil can result in a second fastener being driven from the tool Grip the handle firmly and let the tool do the work Failure to heed this warning can result in serious personal injury Do not drive fasteners on top of other fasteners or with the tool at an overly steep angle as this may cause deflection of fasteners which could cause injury Do not actuate the tool unless you intend to drive a fastener into the workpiece Always handle the tool with care Respect the tool as a working implement Never engage in horseplay Never pull the trigger unless nose is directed toward the work Keep others a safe distance from the tool while tool is in operation as accidental AIR SUPPLY AND CONNECTIONS The connector on the tool must not hold pressure when air supply is disconnected If an incorrect fitting is used the tool can remain charged with air after disconnecting and thus will be able to drive a fastener even after the air line is disconnected possibly causing injury 1 888 669 5672 MODEL PFBC940 REEMAN Do not use oxygen combustible gases or bottled gasses as a power source for
9. ged and Comfortable resulting in a light weight tool great for extended use AIR FILTER Keeps interior components debris free extending tool life ADJUSTABLE DEPTH Depth is easily adjustable for various applications OPERATION ADJUSTING THE EXHAUST The adjustable exhaust A on the cap of the tool allows users to direct the exhaust according to operator preference To adjust the direction turn the exhaust cap in the desired direction Adjustable exhaust A CHANGE THE NOSE COVER The tool is packed with another regular nose cover with which the nailer can be changed to be a regular brad nailer stapler 04 HTTP WWW FREEMANTOOLS COM 1 Disconnect the tool from air resource 2 Remove fasteners from the tool Failure to do so will cause the fasteners to eject from the front of the tool 3 Pull up on the latch B and open the flooring nose cover C 4 Remove the O ring D and pin E 5 Remove the Flooring nose cover C 6 Pull the Regular nose cover F on the nose of the nailer 7 Put the Pin E and O ring D back 8 Push the latch back to the Nose cover on the nailer s nose Flooring nose cover C 1 888 669 5672 REEMAN MODEL PFBC940 NOTE It s the same to change the regular nose cover to the flooring nose cover LOADING FASTENERS 1 Connect the tool to the air resource 2 Push down on the latch button G Pull back on the magazine cover H 3
10. is no fastener in the magazine before adjusting the floor plate FIRING THE TOOL SINGLE FIRING MODE The tool is specially designed for single firing mode This mode requires the trigger to be pulled each time a fastener is driven The tool can be actuated by depressing the work contact element against the work surface followed by pulling the trigger The trigger must be released to reset the tool before another fastener can be driven A WARNING During normal use the tool will recoil immediately after driving a fastener This is a normal function of the tool Do not attempt to prevent the recoil by holding the tool against the work Restriction to the recoil can result in a second fastener being driven from the tool Grip the handle firmly and let the tool do the work Failure to heed this warning can result in serious personal injury MAINTENANCE A WARNING Any time inspection maintenance and cleaning are done Disconnect the tool from the air resource Empty the magazine completely 08 HTTP WWW FREEMANTOOLS COM ANTI DUST Each FREEMAN tool is packed with an anti dust cap on the air connector Keep the anti dust cap cover the air connector when the tool is not in use LUBRICATION The tool is uniquely designed not to need daily lubrication But lubrication is required for best performance after long periods use Oil for pneumatic fastening tools is added through the air line connec
11. ng protection when using the tool Prolonged exposure to high intensity noise may cause hearing loss HTTP WWW FREEMANTOOLS COM Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Without symbol Indicates a situation that may result in property damage Use safety equipment A dust mask non skid safety shoes and a hard hat must be used for the applicable conditions Wear a full face shield if you are producing metal filings or wood chips Dress properly Do not wear loose clothing or jewelry Contain long hair Keep your hair clothing and gloves away from moving parts Loose clothes jewelry or long hair can be caught in moving parts Stay alert watch what you are doing and use common sense when operating a power tool Do not use tool while tired or under the influence of drugs alcohol or medication A moment of inattention while operating the tool may Cause serious injury Avoid unintentional firing Keep fingers away from trigger when not driving fasteners especially when connecting the tool to the air supply Keep proper footing and balance at all times Proper footing and balance enables better control of the tool in unexpected situations Do not use on a ladder or unstable supports Stable footing on a solid surface enables better cont
12. not attempt to use this product until you read thoroughly and understand manual completely the manual Save this manual and review frequently for continuing safe operation and instructing others who may use this tool In this manual on the labels packages and all other information provided with this tool The following signal words and meanings are intended to explain the levels of risk associated with this tool SYMBOLS SIGNAL MEANING A WARNING A CAUTION CAUTION GENERAL SAFETY RULES WORK AREA Keep the work area clean and well lighted Cluttered benches and dark areas increase the risks of accidents Do not operate the tool in explosive atmospheres such as in the presence of flammable liquids gases or dust The tool creates a spark which may ignite flammable liquids gases or dust Keep bystanders children and others away while operating the tool Distractions could result in improper use and cause injury Avoid unintentional misfires Always use caution to avoid accidentally firing Do not point towards yourself or anyone whether it contains fasteners or not PERSONAL SAFETY Always wear eye protection Operator and others in the work area should always wear ANSI approved safety goggles with side shields Eye protection is used to guard against flying fasteners and debris which may cause severe eye injury You can use the goggles packed with the tool Always wear heari
13. rce Turn the depth wheel left or right to change the driving depth Reconnect the tool to the air resource desired depth is set HTTP WWW FREEMANTOOLS COM NOTE When using the tool as a flooring nailer the depth adjustment wheel must be set at the top of the wheel bar To set the wheel 1 Turn the wheel right to move the wheel up 2 Set the wheel at the top of the wheel bar CAUTION It is advisable to test the depth on a scrap workpiece to determine the required depth for the application To determine depth of drive first adjust the air pressure and drive a test fastener Never exceed 120psi ADJUST THE FLOORING PLATE When the flooring nose cover is set on the nailer the floor plate depth is adjustable for 3 8 5 8 and 1 2 thickness floor wood To adjust the floor plate depth please follow the steps as listed below 1 Disconnect the tool from air resource 2 Loosen the plastic screws K on both side of the Floor plate L 3 Slide the Floor plate up or down to suit your flooring application 4 Fasten the Plastic screws tightly 5 Ensure the correct depth set for the wood floor by firing into a scrap piece of flooring and checking for proper fastener placement 1 888 669 5672 07 MODEL PFBC940 REEMAN Plastic Screws K Floor plate L A WARNING Disconnect the tool from the air resource whenever you adjust the floor plate Make sure there
14. rol of the tool in unexpected situations Make sure the hose is free of obstructions or snags Entangled or snarled hoses can cause loss of balance or footing and may become damaged resulting in possible injury 1 888 669 5672 01 MODEL PFBC940 REEMAN TOOL USE AND CARE Know this tool Read manual carefully learn its applications and limitations as well as the specific potential hazards related to this tool Use only fasteners that are recommended for your models Do not use the wrong fasteners or load the fasteners incorrectly Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the tool s operation If damaged have the tool serviced before using Many accidents are caused by poorly maintained tools Maintain tools with care Keep tool clean A properly maintained tool reduces the risk of binding and is easier to control Store tools out of the reach of children and other untrained people Tools are dangerous in the hands of untrained users Check operation of the tool before use Do not use the tool if the workpiece contact mechanism is not working correctly as accidental driving of a fastener may occur Do not use tool if trigger does not actuate properly Any tool that cannot be controlled with the trigger is dangerous and must be repaired Do not force tool Use the correct tool for your application The correct tool will do the job
15. ssing please call 1 888 669 5672 HTTP WWW FREEMANTOOLS COM PACKING LIST Mini flooring tool Air connector Adjustment tools Lubricating oil Instruction manual Safety goggle Brad nailer Stapler nose cover A WARNING If any parts are missing do not operate this tool until the missing parts are replaced Failure to do so could result in possible serious personal injury A WARNING Do not attempt to modify this tool or create accessories not recommended for use with this tool Any such alteration or modification is misuse and could result in hazardous condition leading to possible serious personal injury SPECIFICATIONS Operation pressure 70 110psi Nails capacity 100pcs Tool weight 4 Ibs Air inlet 1 4 NPT Fasteners 18 Gauge sa 63mm rr 15mm SE ae y 0 050 _ lt 20mm 3 4 13mm uz 1 25mm 25mm Li 16mm 58 N 30mm 1 3 16 19mm 34 32mm 1 1 4 25mm ACs aa ar amp P 32mm 1 114 210 Semm 1 12 am az IS 40mm 1 5 8 40mm V158 Compatible with All Generic 18 Gauge nails and staples 1 888 669 5672 03 MODEL PFBC940 REEMAN FEATURES 360 ADJUSTABLE EXHAUST Allows user to direct air away from debris OIL FREE DESIGN For less maintenance ANODIZED ALUMINUM CYLINDER AND MAGAZINE For long lasting durability COMFORT GRIP HANDLE For increased comfort and control ERGONOMICALLY ENGINEERED BODY Rug
16. this tool Explosion may occur causing injury or death Do not connect with an air compressor which can potentially exceed 200 Psi As tool may burst possibly causing injury Always disconnect air resource Before making adjustments When servicing the tool When clean a jam When tool is not in use When moving to a different work area as accidental actuation may occur causing LOADING TOOL Do not load the tool with fasteners when any one of the operating controls is activated Never place a hand or any part of body in fastener discharge area of tool Never point tool at anyone Do not pull the trigger or depress the workpiece contact as accidental actuation may occur possibly causing injury A WARNING The warnings and precautions discussed above cannot cover all possible conditions and situations that may occur It must be understood by the user that common sense and caution are factors which cannot be built into this product but must be supplied by the user UNPACKING This tool has been shipped completely assembled Make sure that all items listed in the packing list are included Carefully remove the tool and any accessories from the box Inspect the tool carefully to make sure no breakage or damage occurred during shipping Do not discard the packing material until you have carefully inspected and satisfactorily operated the tool if any parts are damaged or mi
17. tion and will lubricate internal parts Do not use detergent oil or additives as these lubricants will cause accelerated wear to the seals and bumpers in the tool resulting in poor tool performance and frequent tool maintenance CAUTION Lubricate tool only with non detergent Pneumatic tool oil CLEANING Avoid using solvents when cleaning plastic parts Most plastics are susceptible to damage from various types of commercial solvents and maybe damaged by their use Use clean cloths to remove dirt dust oil grease etc A WARNING Do not at any time let brake fluids gasoline petroleum based products penetration oils ect come in contact with plastic parts Chemicals can damage weaken or destroy plastic which may result in serious personal injury COLD WEATHER OPERATION For cold weather operation near and below freezing the moisture in the air line may freeze and prevent tool operation We recommend the use of air tool lubricant or permanent antifreeze ethylene glycol as a cold weather lubricant CAUTION Do not store tools in a cold weather environment to prevent frost or ice formation on the tool s operating valves and mechanisms that could cause tool failure 1 888 669 5672 MODEL PFBC940 REEMAN RECOMMENDED HOOKUP CAUTION A WARNING The air compressor must be able to maintain a minimum of 70psi when the tool is being used An inadequate air supply can cause a loss
Download Pdf Manuals
Related Search
Related Contents
formation26janvier/accompagnement/Coaching guide Commercial Electric GCI 8011A Instructions / Assembly 携帯通信 システム bat2-alt-manual - Museum of Computer Adventure Game History AG Clopyralid Gen gal Booklet Nuance Dragon NaturallySpeaking 12 Legal Modèles Mise sous tension Guide de démarrage rapide My Book® Home Edition™ Benutzerhandbuch Copyright © All rights reserved.