1. FV 08 11VF5 Vacuum cleaner FV 08 11VFM5 PRACTICAL GUIDE TO INSTALLATION Properly insulate the area around the fan to minimize building heat loss and gain Fig 18 Loose fill or batt insulation can be placed directly over the fan housing in the attic Our fans and fan light combination units do not create excessive heat that is a common problem with recessed light fixtures or some competitor s fan light combination Our efficient cool running motors and our fluorescent lamps do not create enough ambient heat to be subjected to these limitations The ducting from this fan to the 3 inch or 4 inch roof jack wall cap or soffit vent with backdraft damper Mechanically connect duct to termination and seal with mastic or approved foil faced tape 2 3 ft straight run before elbow In attic installation caulk box to drywall SSE KMA lt lt _ _ A short piece of flexible duct helps bs asia alignment and absorbs sound TO Use clamps plus mastic or approved Foil tape tightly covers all metal foil faced tape at all flex joints duct joints Glue PVC joints outside of the building has a strong effect on the air flow noise and energy use of the fan Use the shortest straightest duct routing possible for best performance and avoid installing the fan with smaller ducts than recommended Insulatin around the ducts can reduce energy loss and inhibit mold growth Fans installed with existing ducts may not a
2. Parname Pick A Flow switch Flex Z Fast bracket Junction box Adaptor connector Adaptor si tor E 9 Fan body Grille WIRING DIAGRAM FV 08 11VFM5 Fan body Junction box PCB Red Capacitor White White nn White Neutral 1 l 4 C P in ic Thermally protecte 114 C Fuse in motor 80 CFM Black a Power supply AC120V 60Hz Black Live Thermally protected Black Blue Green Sensor White PCB Earth ground gt FV 08 11VF5 Fan body Junction box PCB Capacitor White White Neutral 114 C Fuse in mr Thermally protected Black 110 CFM Black id T Black Yeo IE OC 114 C Fuse in motor Thermally protected Power supply AC120V 60Hz Earth ground gt FEATURE Pick A Flow Feature These products come with Pick A Flow speed option The Pick A Flow switch on the surface of the products allows the option to choose 80 110 CFM 80 CFM 110 CFM 80 CFM switch INSTALLATION NEW CONSTRUCTION The fan position between joists from 16 to 24 on center can be adjusted flexibly A CAUTION Please wear gloves to protect hands during the installation as follow 1 Remove the junction box and duct adaptor from the fan housing before installing the fan Remove the machine screw M4X6 and disconnect the electrical molex cable by pinching the tabs to insure the junction box and adaptor clear the fan housing when slidin
3. of sensor unit into the clasps 5 positions Fig 10 J Dy y ea aw sensor Halll im n gt 1g eZ in ita MID CAUTION Mount grille carefully so that lead wire of sensor unit is not pinched UA 13 Insert the mounting springs into the slot as shown and mount grille to fan body Fig 11 screw _ 2 Self drilling M4X6 screws Fig 6 After finishing the ceiling job fill gap between flange and ceillng with caulk or other sealant to prevent air leakage INSTALLATION RETROFIT Circular Unit inches mm A WARNING sie t l PN Joist o Disconnect power source before working _ty A lt on unit N T 1 Remove the existing fan and cut ceiling opening Install the Flex Z Fast bracket to joists by using Ceiling already existed 4 10 7 8 275 the 4 pre installed tapping screws ST4 2x20 Leave existing ductwork and wiring in place Fig 12 ircul 2 Follow the step 1 4 5 7 on page 7 Before EO Mastic or connect the circular exhaust duct to the adaptor approved pull down the circular duct from the ceiling K i foil tape Knock out hole 3 Install the adaptor to Flex Z Fast bracket by using Junction box 2 self drilling screws Fig 13 cover Ceiling 2 Self drilling screws Fig 13 4 Secure the f
4. or approved Knock out hole Junction box cover Earth ground to green wire Junction box Neutral to white wire black wire INSTALLATION NEW CONSTRUCTION CONTINUED 8 Insert fan body and slide into adaptor assembly until the flange overlaps the Flex Z Fast bracket Secure the fan body to Flex Z Fast bracket by using 2 self drilling screws plug connector to receptacle and secure the fan body to adaptor by using machine screw M4X6 Fig 6 A CAUTION Secure the duct adaptor to the fan housing with the machine screw M4X6 by re inserting and carefully screwing the adaptor to the housing Please insure the screw is appropriately placed so it does not strip the teeth nor come in contact with the Flex Z Fast bracket 9 Finish ceiling work Ceiling hole should be aligned with the inside edge of the flange Fig 7 10 Select the air volume speed by adjusting the switch Factory setting is 80 position sliding 110 is high airflow position Fig 8 CAUTION Make sure the switch is not set at the middle position otherwise the fan will not function Fig 8 11 Remove the tapes from the louver and springs before installing the grille to the fan Remove screw M4X8 and light cover Fig 9 12 For FV 08 11VFM5 Insert the sensor unit into the slot of the grille fix the lead wire
5. Panasonic INSTALLATION INSTRUCTIONS Ventilating Fan Model No FV 08 11VFM5 FV 08 11VF5 Contents GENERAL SAFETY INFORMA TION rsssssssssssssstssssssesssseesssseessneessaneeen 2 3 DESORPTION GON eee ee SF 4 UNPACKY NG uu A 4 SUPPLIED ACCESSORIES ieu 4 DIMENSIONS ueu IA 5 WIRING DIAGRAM ee 6 FEATURE 5eeeieeeeneeee A 6 INSTALLATION NEW CONSTRUCTION me 7 8 INSTALLATION RETROFIT rennir 9 MAINTENANCE CLEANING cvvssssssssssssssssssssseeessseeesseeernseesnnsnennnnnen 10 PRACTICAL GUIDE TO INSTALLATION it 11 SPECIFICATIONS ueu LU 14 PRODUCT SERVICE FA BACK COVER READ AND SAVE THESE INSTRUCTIONS Thank you for purchasing this Panasonic product Please read these instructions carefully before attempting to install operate or service the Panasonic product Failure to comply with instructions could result in personal injury or property damage Please explain to users how to operate and maintain the product after installation and this booklet should be presented to users Please retain this booklet for future reference GENERAL SAFETY INFORMATION For Your Safety To reduce the risk of injury loss of life electric shock fire malfunction and damage to equipment or property always observe the following safety precautions Explanation of symbol word panels The following symbol word panels are used to classify and describe the level of hazard injury and property damage caused when the denotation is disregar
6. an body to Flex Z Fast bracket by using 2 self drilling screws plug connector to receptacle and secure the fan body to adaptor by using machine screw M4X6 Fig 14 CAUTION Secure the duct adaptor to the fan housing with the machine screw M4X6 by re inserting and carefully screwing the adaptor to the housing Please insure the screw is appropriately placed so it does not strip the teeth nor come in contact with the Flex Z Fast bracket i Machine screw M4X6 a 2 Self drilling screws fix the flange and Flex Z Fast bracket through the ceiling 5 Follow the step 10 to 13 on page 8 Fig 14 10 MAINTENANCE CLEANING AWARNING O Disconnect power source before working on unit CAUTION Routine maintenance must be done every year Please wear gloves during the cleaning work Never use gasoline benzene thinner or any other such chemicals for cleaning the ventilating fan Do not immerse motor in water when cleaning Do not soak resin parts in water over 140 F 60 C 1 Clean grille Don t put into hot water Use non abrasive kitchen detergent wipe dry with clean cloth Fig 15 2 The grille should be dry after cleaning 3 Remove dust and dirt from fan body using a vacuum cleaner Fig 16 4 Using a cloth dampened with kitchen detergent remove any dirt from fan body Wipe dry with clean cloth Fig 17 5 Reinstall grille FV 08 11VFM5 FV 08 11VF5 Vacuum cleaner
7. chieve their rated air flow SPECIFICATIONS FV 08 11VFM5 FV 08 11VF5 V Hz Voltage Frequency Pata inches C CES A Air volume at 0 1 WG CFM Noise sones an Ib kg a Power Weight rpm so os eo ze DS o os pros 270 m os ame 209 26 4 we as ww asa om os oo ma 62 o os os 265 HVI Certified performance based on HVI Procedures 915 916 and 920 11 PRODUCT SERVICE Warning Concerning Removal of Covers The unit should be serviced by qualified technicians only Your product is designed and manufactured to ensure a minimum of maintenance Should your unit require service or parts call Panasonic Call Center at 1 866 292 7299 USA or 1 800 669 5165 Canada Panasonic Corporation of North America Two Riverfront Plaza Newark NJ 07102 www panasonic com Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario LAW 2T3 www panasonic ca O Panasonic corporation 2015 Printed in China X0315 0 08VF50420
8. ded and improper use is performed A WA R N N G GU potential hazard that could result in serious injury A CAUTI O N Denotes a hazard that could result in minor injury The following symbols are used to classify and describe the type of instructions to be observed o This symbol is used to alert users to a specific operating procedure that must be followed in order to operate the unit safely performed S This symbol is used to alert users to a specific operating procedure that must not be This symbol is used to alert users not to disassemble the eguipment with the grounding terminal eb This symbol is used to alert users to make sure of grounding when using the eguipment A WARNING To reduce the risk of fire electric shock or injury to persons observe the following o ap Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases
9. g the adaptor off the housing Fig 1 IMPORTANT Please remove the tape which protects the damper during shipping and installation from r as shown below Adaptor Damper Connection method for 3 inch adaptor connector Duct tape 2 Bend down 4 tabs for positioning install the Flex Z Fast bracket to joists by using the 2 pre installed tapping screws Fig 2 3 Adjust the length of Flex Z Fast bracket to fit the spacing between joists fix the Flex Z Fast bracket with the other two pre installed tapping screws Fig 3 4 Remove junction box cover and secure conduit or stress relief to junction box knock out hole Fig 4 5 Install the circular exhaust duct and secure it with clamps or ties and seal it with mastic or approved foil tape Fig 4 6 Install the adaptor to Flex Z Fast bracket by using 2 self drilling screws Fig 4 7 Refer to wiring diagram on page 6 Follow all the local electrical safety codes as well as the National Electrical Code NEC Using UL approved wire nuts connect house power wires to ventilating fan wires Fig 5 A CAUTION Mount junction box cover carefully so that lead wires are not pinched Insure the junction box cover encloses all the wires and is completely flush before locking in place with the attached screw Bend down 4 tabs 2 Tapping screws ST4 2X20 Fig 2 Flex Z Fast bracket 2 Tapping screws ST4 2X20 Circular exhaust Mastic
10. se motor humming noise These products must be properly grounded Do not install these ventilating fans where interior room temperature SO Z 8 Extreme may exceed 104 F 40 C Prohibited aU Make sure that the electric service supply voltage is AC 120V 60Hz Su Follow all local electrical and safety codes as well as the National Bend Prohibited tedl Electrical Code NEC and the Occupation Safety and Health Act OSHA ea ei Always disconnect the power source before working on or near the fan Qc motor or junction box Duct o Prohibited narrow Protect the supply wiring from sharp edges oil grease hot surfaces chemicals or other objects Fan body 7 Adaptor Do not kink the supply wiring S Prohibited Provide make up air for proper ventilation Bend near SOOOSOSSSSO F GOOSSOOE adaptor Fig A For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors Cooking area Do not install the unit where ducts are configured as shown Do not install above or in Fig A ST as ig Not for use in cooking area Fig B Nd K The special purpose or dedicated parts such as mounting ee Floor fixtures must be used if such parts are provided Fig B DESCRIPTION These Panasonic ventilating fan models are listed by UL under UL file No E78414 These Panasonic ventilating fan models use a sirocco Blower driven by a capacitor motor The motor is designed to have an ex
11. tended service life with reduced energy consumption It also incorporates a thermal cutoff for safety The grille covering the fan body is a spring loaded quick remove type Adamper for preventing air counterflow is provided The blower uses a high capacity sirocco fan developed to reduce the noise level These products have two speeds 80 is low airflow and 110 is high airflow FV 08 11VFM5 is equipped with a motion sensor that shifts the fan to vent automatically when motion is detected It stops the flow automatically after 20 minutes when motion is no longer detected UNPACKING Unpack and carefully remove the unit from carton Refer to the supplied accessories list to verify that all parts are present SUPPLIED ACCESSORIES Installation 5j gt 4 instructions FV 08 11VFM5 Grille Warranty Self drilling Flex Z Fast bracket seh 3 inch adaptor with 4 tapping lt T 1 connector screw A optional part ST4 2X20 DIMENSIONS Unit inches mm FV 08 11VFM5 12 1 8 307 2 15 16 74 LY is S Ba N NIE oid NEHO 3 7 8 98 T Partname No Paras unan box Herz Fast bracket Adaptor 40 Adaptor connector Main ey ranbody 3 3 8 85 10 1 4 260 6 150 FV 08 11VF5 12 1 8 307 paree No
12. through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities o Ducted fans must always be vented to the outdoors If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit GENERAL SAFETY INFORMATION CONTINUED AWARNING These models are UL listed for tub and shower enclosures Canada only Not to be installed in a ceiling thermally insulated to a value greater than R40 Do not disassemble the unit for reconstruction It may cause fire or electric shock A statement to the effect that when the product is to no longer be used it must not be left in place but remove to prevent it from possibly falling Ceiling joist must be subjected to static load more than five times the weight of the product Do not install with a method which is not approved in the instructions Do not use these fans with any solid state speed control device Solid state controls may cause harmonic distortion which can cau