1.  all installations to assure proper operation and to prevent debris from entering the venting system    E  The Z Vent system must be free to expand and contract  Pipe must be properly supported  Vertical runs must us firestops as  lateral support at each ceiling level and at least one support collar at the base of the vertical run  For vertical runs exceeding 16    4 88 m   a support collar is required at 16   4 88  m  intervals  Horizontal runs require a loose fitting metal strap or similar support  at each joint    F  Examine all components for possible shipping damage prior to installation    G  Proper joint assembly is essential for a safe installation  Follow these instruction exactly as written  Check severeness of joints  upon completion of assembly    H  Check for unrestricted vent movement through walls  ceilings and roof penetrations    I  Different manufacturers have different joint systems and adhesives  Do Not Mix Pipe  Fittings or Joining methods from  different manufacturers     Oo OAO    g    oe    KIT CONTENTS    Inspect the kit to verify the following parts are present before proceeding with the installation  Contact Hamilton at  1 800 879 0123 if a part is missing  Read the instructions completely before installing     sw OOS                  ae     12  Appliance  Screened Vent     ae E Js Vent Adapter  Termination Tee 3  Gear Clamp   o AUTE  ON     Wall Thimble    JOINT PROCEDURE    The female end of each Z Vent III component incorporates a silicone sealin
2.  be filed or sanded smooth before joining     The minimum length of the venting system must be 3 ft     Note  The Gear Clamp must be installed around the Vent Pipe on the interior of the wall to secure pipe in  position so that the system remains stationary   This applies to both combustible and non combustible  walls   See illustration on Page 5    4  Verify that all joints are connected properly  Tighten all Locking Bands  including the locking band  from step  2 above  and the Gear Clamp  Allow 1 hour for the High Temperature Silicone to cure  before using the Garage Heater     IMPORTANT NOTICE    When the previous installation procedures are completed  examine the entire venting system to verify that  all joints are secure and sealed correctly  The seams and joints must be checked for tightness prior to using  the venting system     The installation must conform to the requirements of the Hamilton WGH Garage Heater instructions  the  National Fuel Gas Code and Federal  State  and Local codes and regulations     Once installation is complete  read the Limited Lifetime Warranty and mail in the Warranty Registration Card     For additional assistance  call Hamilton Home Products  Inc  at 1 800 879 0123 or visit their web site at  www HamiltonHomeProducts com        Hamilton SVE 3 Horizontal Stainless Steel Vent Kit Assembly     For Downward Sloping Side Wall Venting Applications Only     Adjustable Wall Thimble    Locking Band Gear Clamp NN Locking Band            Screened V
3. IES  INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FORA  PARTICULAR PURPOSE  IMPOSED ON THIS SALE UNDER STATE LAW  ARE LIMITED TO THE PERIOD DURING  WHICH THIS WARRANTY IS IN EFFECT  AS SOME JURISDICTIONS DO NOT ALLOW LIMITATIONS ON THE  LENGTH OF AN IMPLIED WARRANTY  THE ABOVE LIMITATION MAY NOT APPLY TO YOU    Claims under this Warranty must be made within the warranty period in writing and directed to  In the USA  Warranty  Claims  Z Flex     US  Inc   20 Commerce Park North  Bedford  New Hampshire 03110   603  669 5136 or  800  654 5600   In Canada  Warranty Claims  Z Flex    Inc   452 Atwell Drive  Etobicoke  Ontario  M9W 5C3   416  649 0045  This  Warranty gives you specific legal rights  and you may also have other rights that vary in different States and Provinces     WARRANTY REGISTRATION CARD  Z FLEX       For this warranty to be effective  this card must be completed upon purchase of the covered Z Vent and returned to  Z Flex    within ninety  90  days of installation of the Z Vent     Original end user s name     Address of premises in which the Z Vent is installed     Z Vent purchased from   Date of installation   Type of Heating System into which Z Vent installed     I understand and agree to the Warranty as stated     Signature Date    Flexmaster Canada Limited  Model SVE Instructions Ver  3 6 July 18  2001    
4. Z VENT    MODEL SVE SERIES Ill  INSTALLATION AND MAINTENANCE  INSTRUCTIONS    Hamilton SVE 3 Horizontal Stainless Steel Venting System    Distributed Exclusively By Hamilton Home Products  Inc     Designed for Hamilton WGH Garage Heaters Being Installed  In Downward Sloping Side Wall Venting Applications Only       Category Ill    cus    LISTED    TESTED AND LISTED BY  UNDERWRITERS LABORATORIES  INC     UL 1738  amp  BH636    FLEXMASTER CANADA LTD Z FLEX US  INC  452 ATTWELL DRIVE 20 COMMERCE PARK NORTH  ETOBICOKE  ONTARIO BEDFORD  NH    MOW 5C3 03110 6911    SPECIAL STAINLESS STEEL VENTING    For use with Category Il  Ill  IV appliances    Contact Local Building or Fire Officials about Restriction and Installation Inspections in you area as well as National Codes   USA   National fuel gas code ANSI Z223 1  CANADA   CAN CGA B 149 1 or  2 Fuel Burning Installation Code    Please refer to appliance manufacturer s instructions to determine proper sizing and connection of venting system to appliance   including maximum horizontal length  maximum height  and installation clearances  air spaces   The proper operation of the vent  system and appliance requires parts specified by Z FLEX with no deletion or substitutions     PARTS LIST    Reducer 4  to 3     Z FLEX recommends that an experienced professional who works with venting system on a regular basis perform the  installation  These instructions are intended as a guide to assist a professional installer   When the Z VENT system 
5. ent  Termination Tee    3  Vent Pipe       12  Appliance  Vent Adapter          Bead of Silicone  on Vent Connector         Note  Vent must  terminate a minimum  of 12  above the  ground or normally  expected snow  accumulation level        Garage Heater  Vent Pipe  Connector         ILLUSTRATION  2    Installation must conform to the requirements of the Hamilton  WGH Garage Heater instructions  The National Fuel Gas    Code  and Federal  State  and Local codes and regulations        Z Flex    LIMITED LIFETIME WARRANTY  Z Flex      Seller   extends the following LIMITED WARRANTY for Z VENT  the  Z VENT       Seller Warrants that at the time of purchase  the Z Vent will be free of manufacturer s defects in material and or  workmanship  This warranty shall extend to the original purchaser of the Z Vent or  if purchased by a contractor  to the  end user  This warranty is valid for a period of fifteen  15  years from the date of purchase  provided that the Z Vent has  been installed according to Z Flex    installation instructions  Deviating from the installation and use instructions included  with the Z Vent will void the warranty    Under this Limited Warranty  Seller s sole responsibility and liability shall be to replace the Z Vent and or accessories   if found by Seller to be defective according to the terms of the warranty  and shall not include replacement installation or  other costs    IMPORTANT  The Z Vent is designed for use with Category Il  Ill and IV furnace and boi
6. g gasket  except for 12  Appliance Vent  Adapter   Examine all components to insure that gasket integrity has remained during shipping  Gaskets must be in  the proper positions or flue gases could leak resulting in carbon monoxide poisoning     Please Note  The connection of the 12  Appliance Vent Adapter to the Garage Heater Vent Pipe Connector requires  a continuous bead of Z Vent high temperature silicone  included  applied to the flange of the Vent Pipe Connector  prior to attaching the Appliance Vent Adapter and tightening Locking Band   See Illustration on Page 5      1  Align pipes and push them together as far as they will go  at least 1 75 inches    2  Tighten Locking Bands and Gear Clamp to a minimum torque of 40 in Ibs  and maximum of 50 in Ibs     JOINT DETAIL    t   _    TO GARAGE HEATER       7    FEMALE END    LOCKING BAND as    ILLUSTRATION  1       CLEARANCE TO COMBUSTIBLES    Temperature Enclosed Unenclosed  O   Horizontal   Vertical   Horizontal __   Vertical ___       480   F  249  C  8   200mm  4   200mm  1   25mm  1   25mm     INSTALLATION FOR  Downward Sloping Side Wall Venting Applications Only   Refer to Illustration on Page 5     1  Penetrating a combustible wall requires the use of a Wall Thimble   If the wall is non combustible  the  Vent pipe may be mortared in directly without using a wall thimble   Install Wall Thimble into wall   observing the aforementioned rules and or local building codes  Select the point of wall penetration  where a minimu
7. is installed  the following should be observed        1  A venting system that exits the structure through a sidewall or the like  shall terminate not less than 12 inches  254 mm  above  the ground  see Illustration  2  Page 5    2  The termination of a system shall be located above the snow line in geographical areas where snow accumulates  The termination  area should be kept clear of snow and ice at all times      The vent shall not terminate less than 7 ft   2 13m  above a paved sidewalk or driveway      The termination shall be 6 ft   1 8 m  or more from the combustion air intake of any appliance      The system shall terminate more than 3 ft    91 m   from any other building opening  gas utility meter  service regulator  or the like      Exterior mounted venting systems should be enclosed below the roof line with a chase to limit condensation and protect against  mechanical failure     NOTES    A  The Z FLEX SPECIAL STAINLESS VENT SYSTEM is for use only with appliances having a positive vent pressure of 8  of water  column or less    B  Except for installation in one or two family dwellings  a venting system that extends through any zone above that on which the  connected appliances located shall be provided with an enclosure having fire resistance rating equal to or greater than that of the  floor or roof assemblies through which it passes    C  Do not place any type of insulation in any required air spaces surrounding the vent system      A termination must be used on
8. ler venting and should not be  used with any other type of furnace and boiler venting  Use of the Z Vent with any other type of furnace and boiler venting  other than those recommended by Seller for use with its Z Vent will void the warranty    WARNING  CONDENSATION WITH HIGH ACID CONTENT MAY BE PRODUCED DUE TO UNFORESEEN  CONDITIONS  YOUR HEATING APPLIANCE AND VENTING SYSTEM SHOULD BE INSPECTED BY A LICENSED  CONTRACTOR ON AN ANNUAL BASIS FOR POSSIBLE SIGNS OF DETERIORATION DUE TO RUSTING OR PIN  HOLES  CONDENSATION WITH HIGH ACID CONTENT MAY CAUSE LEAKAGE OF HARMFUL GASES WHICH CAN  CAUSE NAUSEA  FAINTING OR DEATH  IF DETERIORATION IS DETECTED CEASE USE OF HEATING SYSTEM  AND CALL FURNACE   BOILER INSTALLER FOR REMEDIAL ACTION    To activate the warranty  the end user must complete and return the Z Flex    Warranty Registration Card within ninety   90  days of installation of the Z Vent  Upon written notice of any defects  Z Flex    reserves the right to examine or  establish reasonable proof of defective material or workmanship justifying replacement    NO OTHER EXPRESS WARRANTY HAS BEEN MADE OR WILL BE MADE ON BEHALF OF SELLER WITH  RESPECT TO THE Z VENT OR THE INSTALLATION OR REPLACEMENT OF THE Z VENT  SELLER SHALL NOT BE  LIABLE FOR ANY SPECIAL  INCIDENTAL  INDIRECT OR CONSEQUENTIAL DAMAGES    As some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages  the above  limitations or exclusions may not apply to you    IMPLIED WARRANT
9. m 1 4  per foot of slope  6 4mm per 305mm  can be maintained   A framed opening is  required to insert the thimble halves  The Wall Thimble can be adjusted for different wall thickness   Caulk around outside edges of plates as necessary and fasten to wall using suitable screws or nails   The Vent Pipe must be sealed at Wall Thimble as per code regarding continuous vapor barrier       IMPORTANT  Category IIl appliances with a downward sloping side wall application must slope not less    than 1 4   6 4mm  every 12   305mm  to prevent collection of condensate at any location  in the assembly        2  Apply a continuous bead of Z Vent High Temperature Silicone to the flange of the Garage Heater Vent  Pipe Connector so that it forms a seal when attaching the 12  Appliance Vent Adapter  do not tighten  locking band on the Garage Heater side of the 12  Appliance Adapter completely at this time      3  Using the joint procedure described on Page  3  assemble the female end of the 3  Vent Pipe to the  Screened Vent Termination Tee  and slide through the Wall Thimble from the exterior  Slip the Gear  Clamp over the end of the Vent Pipe as it passes through the interior portion of the Wall Thimble  and  connect Vent Pipe to the 12  Appliance Vent Adapter  Once all connections are made  make sure that  the Screened Vent Termination Tee is positioned horizontally     Note  The length of the Vent Pipe may be cut on the male end using aviation snips or a hacksaw  24 tpi    The cut end must
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Aga gaz GC3 CF aims instal 03-10 EINS 515537  JVC LT-Z32FX60 User's Manual    Westinghouse 30-Inch Specification Sheet  LE BILAN PEDAGOGIQUE ET FINANCIER : MODE D`EMPLOI  Panasonic Toughbook T7 User's Manual  Rexel 12224 folder  Manhattan 560672 network switch  SKI 4 User manual 4    Copyright © All rights reserved. 