Delta Breez SIG80MLED Instructions / Assembly
Contents
1. Option 2 Attach the duct connector from the housing can inside and secure using the duct screw M4X12 j NN f i Pull existing ductwork into Housing AA Duct screw M4X12 i q from Parts Bag Insert tab into slot in Housing Note Remove the tape from the damper and adaptor before installation 1 dg oreez Signature MODEL SIG8OMLED Page 2 Using suspension brackets Sliding suspension brackets are provided to allow for positioning of the housing any where between joists up to a span of 24 Insert the suspension brackets into the channels on the housing Make sure the tabs face up as shown Fig C Extend the suspension brackets to fit the width of the joists Hold the fan in place by wrapping the suspension bracket tabs around the bottom of the joist Make sure the fan body is level and perpendicular to the joist Fig D amp E Ensure that the distance between the ceiling and fan body is appropriate for mounting the grille Secure the suspension brackets to the joists with nails or by using the tapping screws 4x25 through holes near nails Secure the suspension bracket to the fan body using the screws 8 32 x 1 4 Follow steps 2 to 6 of the installation to complete the installation work Body Suspen
2. ce breez MODEL SIG8OMLED AELTA monet sicsomitt Page 1 INSTALLATION AND OPERATING INSTRUCTIONS VENTILATION FAN LED LIGHT w MOTION SENSING READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION 1 Make sure that the electric service supply voltage is AC 120V 8 Do not use this unit with any other solid state control device 60Hz Solid state controls may cause harmonic distortion which can 2 Follow all local electrical and safety codes as well as the cause a motor humming noise National Electrical Code NEC and the Occupational Safety p and Health Act OSH Act 9 NEVER place a switch where it can be reached from a tub or shower re ee a si iene nara SSE 10 Notto be installed in a ceiling thermally insulated to a value oem J greater than R40 This is required for installation in Canada 4 Protect the power cord from sharp edges oil grease hot only surfaces Chemicals OF OMET OBJEC 11 Do not open disassemble the LED light engine 5 Donot kink the power cord 6 Donotinstall the unit where ducts are configured as shown in Turning angle too large Duct shrink Fig A 3 Cei Provide suction parts with proper ventilation This unit is UL listed for use over a bathtub or shower when S installed in a GFCI Ground Fault Circuit Interrupter protected branch circuit Too many elbows Elbow near the body 9 These ventilating fans are intended for residential usage only ee Body
3. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING _ 1 Use this unit only in the manner intended by the Fig A manufacturer If you have questions contact the manufacturer CAUTION 2 Before servicing or cleaning the unit switch the power off at 1 For general ventilating use only Do not use to exhaust the service panel and lock the service disconnecting means to hazardous or explosive materials and vapors prevent the power from being switched on accidentally When the service disconnecting means cannot be locked securely 2 Not for use in cooking areas Fig B fasten a prominent warning device such as a tag to the 3 This product must properly connect to the grounding service panel conductor of the supply circuit 3 Installation work and electrical wiring must be done by 4 To reduce the risk of injury to persons install the fan at least qualified person s in accordance with all applicable codes 8 2 feet 2 5 m above the floor and standards including fire rated construction 4 Sufficient air is needed for proper combustion and exhausting i of gases through the flue chimney of fuel burning i D e m t install above or equipment to prevent back drafting Follow the heating omor equipment manufacturer s guideline and safety standards N S P inside this area Zx y 7 such as those published by the National Fire Protection s y Association NFPA and t
4. he American Society for Heating X Refrigeration and Air Conditioning Engineers ASHRAE and Ny Bey local code authorities AN TX 5 When cutting or drilling into a wall or ceiling do not damage a electrical wiring and other hidden utilities Cooking i fl 6 Ducted ventilating fans must always be vented to the Equipment ok outdoors Fig B 7 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI protected branch circuit SUPPLIED ACCESSORIES A NELTA Part name Appearance Quantity Grille lt gt l Tapping Screw atl i 4x25 Screw Wy 8 32x1 4 4 Duct connector E gt 1 Duct Screw A 1 M4x12 Suspension bracket z 5 13 318 5 Y Suspension bracket 2 13 318 5 NS Inches mm INSTALLATIONS Proper insulation around the fan to minimize building heat loss and gain Roof cap lt lt Sy with built in Short piece of flexible damper duct helps alignment and absorbs sound Fan housing lt t or a gt Wall cap Seal gap Caulk termination ae around housing o duct Attach Duct Connector Option 1 Attach the duct connector from outside and secure using the duct screw M4X12 Insert tab into slot in housing Duct screw M4X12 from Parts Bag
5. or abnormal vibrations or sounds Celling LED light connector Grille Fig G Slots a a Spring j ul J Motion sensor connector Fig H A NELTA 5 Operation Delay time control Low speed air volume preset control 5 1 Motion control mode Turn the POWER switch on to operate at motion control mode When motion is detected the fan will run at full speed and the LED indicator will be amber When motion is not detected the fan will continue to run at the full speed until the user adjustable time delay has elapsed and then will automatically change to the user adjustable low speed airflow The LED indicator will be green MAINTENANCE WARNING Disconnect the power source befo re working on the unit Routine maintenance must be done every year CAUTION 1 Never use gasoline benzene thinner or any other such chemicals to clean the ventilating fan 2 Do not allow water to enter the motor 3 Do not soak resin parts in water over 60 C 140 F CLEANING 1 To remove the grille pull down the spring and power connects of the LED light engine 2 Wash and clean the grille carefully CAUTION Do not let water into the LED light engine Use non abrasive kitchen detergent and wipe dry with a clean cloth 3 Remove dust and dirt from the ventilating fan 4 Using a cloth dampened with non abra
6. or is reusable on solid wires of the same wire gage or smaller Do not reuse the connector on stranded wires NOTE Important wire information Maximum temperature rating 105 C 221 F 600 volts maximun for building wire and 1000 volts maximum in signs and lighting fixtures The acceptable wire range includes Solid 12 18 AWG Quick connector House wire N Product E wire Strip wire 3 8 1 2 e Grip the wire firmly and push the stripped end of the wire into the open port of the connector Use only one conductor per port e Verify the stripped end of the wires is fully inserted to the back of the connector MODEL SIG8OMLED Page 3 ees RED BLACK YELLOW ON OFF SWITCH purchase separately SWITCH BOX WIRING PLATE NIGHT LIGHT POWER LIGHT SWITCH SWITCH SWITCH 120 VAC LINE IN 3 4 Using quick connector connect house power wires to ventilating fan wires 3 5 Using wire nut not provided connect house ground wire to fan ground wire 3 6 14 AWG 2 1 mm 2 is the smallest conductor that shall be used for branch circuit wiring 4 Grille attachment 4 1 Insert the LED light connector into the main body Fig G 4 2 Insert the motion sensor connector into the main body and mount the grille to the body Fig H 4 3 Insert the mounting springs into the slots Fig H 4 4 With the power on check f
7. reof due to a physical environment beyond the requirements of products specifications Address 4405 Cushing Parkway Fremont CA 94538 US Toll Free Number 1 888 979 9889
8. sion Bracket Suspension Bracket Il Fig C 16 406mm 19 2 487mm i 24 609mm E KA SSS Fig D oe Joist 2 i a e A A Za A NELTA 2 Duct connection Inside Outside Tape Body Duct ji 1 Pe 4 q Ceiling Gradient 1 2 Duct connector Fig F 2 1 Insert the duct into the duct connector and tape all ductwork connections to make them secure and airtight Fig F 2 2 Install the duct with a gradient of 1 2 to the outside 3 Connect wiring 3 1 Follow all local electrical and safety codes 3 2 NEVER place a switch where it can be reached from a tub or shower 3 3 Connect wires as shown in the wiring diagrams below JUNCTION BOX SWITCH BOX OFF RED O on L WHITE LIGHT SWITCH OllOr e gt N OFF YELLOW OlO 2 owo gt L WHITE NIGHT LIGHT SWITCH OllO gt N OFF ee BLACK OlO On SO gt L WHITE POWER SWITCH O N GREEN e GRD QUICK CONNECTOR INSTRUCTIONS To be sold only with installation instructions WARNING Wiring must comply with all applicable electrical codes Turn OFF power before removing or installing connectors WARNING COPPER TO COPPER ONLY Do not use Aluminum wire CAUTION Accessory part quick connector should meet installation instructions NOTE The connect
9. sive kitchen detergent remove any dirt from ventilating fan Wipe dry with a clean cloth 5 Replace the grille DIMENSIONS ga zg AS n Alm MN OJN mif n 7 31 185 7 Unit Inches mm 245 8 MODEL SIG80MLED Page 4 SPECIFICATIONS FAN Modelno VOe egen gorp eare YEM gon w CFM W SIG8OMLED 120 60 8 9 80 10 31 0 Note Design and specifications subject to change without notice SPECIFICATIONS LED LIGHT ENGINE TE SPEC DIMENSION CINCH 8Lx4 4Wx1 4H AIN LIGHT POWER CONSUMPTION W 13 IGHT LIGHT POWER CONSUMPTION W 2 AIN LIGHT LUMINOUS FLUX LM 800 CORRELATED COLOR TEMPERATURE K 2700 LIGHT SOURCE LIFE HOURS 30000 MIN TRANSIENT PROTECTION CLASS A OPERATING FREQUENCY HZ 120 FCC QUALIFIED YE ENERGY QUALIFIED YE ROHS QUALIFIED YE SAFETY REQUIREMENTS UL cUL WARRANTY DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY Delta Electronics Inc Delta Electronics warrants to the original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in material or workmanship This warranty is limited to three 3 years from the original date of purchase Limitations and Exclusions During the warranty period a replacement for any defective product will be supplied free of charge for installation by the consumer The
10. warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting repair removal and installation service 2 All returns of defective parts or products must include the product model number and must be made through an authorized Delta Electronics distributor Authorized returns must be shipped prepaid Repaired or replacement products will be shipped by Delta Electronics F O B shipping point 3 Delta Electronics shall not be liable for any indirect incidental consequential punitive or special damages arising out of or in connec tion with products use or performance regardless of the form of action whether in contract tort including negligence strict product liability or otherwise 4 This warranty does not extend to fluorescent lamp starters and tubes 5 The warranty does not cover if user does not comply with manufacturer s installation manual 6 To qualify for warranty service you must notify Delta Electronics at the address or telephone number below 7 Delta Electronics shall have no liability to the original owner user with respect to any defect caused by abuse misuse neglect improper transportation or storage improper testing improper installation improper operation improper use improper maintenance improper repair improper alteration improper modification tampering or accident of products or parts thereof or unusual deterioration or degradation of products or parts the
Download Pdf Manuals
Related Search
Related Contents
F44 How to use Leica TP1020 Automatic Tissue Processor Curso Sushiman - Cursos Online SP Frigidaire FFTR2126PS fridge-freezer 全文 - 裁判所 Steba SG 20 www.philips.com/welcome ASUS B451JA LT9582 User's Manual Samsung Galaxy Mega Felhasználói kézikönyv(KK) MANUALE OPERATIVO Copyright © All rights reserved.