1.    Safety PLUS ADVANTAGE       COATED STAINLESS STEEL GAS CONNECTORS  INSTALLATION INSTRUCTIONS    For Residential  and Commercial  Gas Appliances       DO NOT INSTALL THIS PRODUCT UNTIL YOU HAVE READ AND UNDERSTAND  ALL INSTRUCTIONS     The Safety PLUS ADVANTAGE    coated stainless steel gas connector combines two  state of the art technologies to deliver a superior gas connector for your home and  family  Safety PLUS ADVANTAGE gas connectors feature an advanced corrosion  resistant coating called ProCoat    A proprietary polymer coating  ProCoat is specially  engineered to resist the corrosion from harsh chemicals found in household cleaning   plumbing repair and masonry products  Approved for indoor and outdoor use  ProCoat  is formulated to resist the harsh effect of UV rays and salt     Safety PLUS   excess flow valves  EFV   an automatic safety valve for gas  utilize a  patented magnet based excess flow technology  In the event of a gas line rupture or  disconnection at the appliance  the Safety PLUS valve immediately restricts gas flow to  a non hazardous level  a bypass flow  to avert the potential for a dangerous release of  gas into the home  Only after the gas line has been properly repaired  the bypass flow  automatically resets the valve  allowing gas flow to resume to the appliance    e Use only on low pressure natural and LP gas piping systems  DO NOT USE on  pipelines or piping systems that transfer or move liquids  including high pressure  liquid propane    e
2.  Use only with gas line pressures at a minimum of 4    water column  W C   and not  greater than 14    W C   1 2 psig  at the stub out    e Use only in connection with residential and commercial gas appliances  where  installation is immediately downstream of the gas supply stub out and manual gas  shut off valve    Tools Needed for Installation    e  2  10  adjustable wrenches  e Pipe dope or gas pipe thread tape  e Leak detection solution  SIZING THE CONNECTOR TO THE APPLIANCE    1  Measure the distance between the gas supply stub out and the appliance   Add 2     3 inches to the measured distance for appropriate connector length for the  installation   See Fig  A     Gas Supply Pipe  Manual Shut off Valve    Safety PLUS  Appliance EFV    Gas Connector  Flare Nut    I    6  Maximum        Massachusetts State Plumbing Code Mandates a maximum  connector length of 36    or 3          2  Identify the maximum  gas  input rating of the  appliance  refered to as    input rating       Manufacturer   s label  located near the gas inlet  of the appliance will contain this information    See Fig  B  Contact the appliance manufacturer  if you are unsure of the correct rating for the  appliance     3  Using Chart 1  select the gas connector with the  maximum flow capacity that is HIGHER than the  input rating of the appliance  However  select the  gas connector with the maximum flow capacity  that is CLOSEST TO the input rating of the  appliance   Figure C        WARNING  The maximum ga
3.  valve before installing to be certain it has not been damaged  Thread  brass Safety PLUS valve to manual gas shut off valve  Using one adjustable wrench  to stabilize the manual gas shut off valve  wrench tighten Safety PLUS valve with  second wrench  Tighten all connections in the same manner     6  Thread steel gas fitting to gas inlet on appliance  Wrench tighten     7  Thread flare nuts of gas connector onto Safety PLUS valve and steel fitting   Wrench tighten both connections     e DO NOT stretch connector to make it fit  Connector should be at least 2     3  inches longer than the distance between the appliance and gas supply   Stretching the connector will stress the stainless steel which may cause cracks  or breaks during appliance use or if accidentally hit     e DO NOT kink  twist or bend connector sharply      doing so will cause the connector to fail   Be careful when installing connector to avoid  pinching or kinking the connector  Figure J      e DO NOT allow connector to become trapped  against sharp edges or corners     e DO NOT use connector if bent tighter than  1 1 2 IN   the diameter of a golf ball    Figure K     8  SLOWLY open the manual gas shut off valve to  allow gas to enter the system  The valve is open and  gas is flowing when the valve handle isparallel to  the valve body  Figure H   NOTE  If gas enters  system too quickly  the Safety PLUS valve may  activate pre maturely  If this occurs  the Safety PLUS valve will re open in less than  60 second
4. 6011 www brasscraft com    325 02 11 11    
5. or  fittings and valve are designed for  use on original installation only  Removal of  connector and additional handling may have  damaged connector making it unsafe for reuse     3  DO NOT use this gas connector on appliances  equipped with rollers or casters   Figure E   This connector is designed for limited movement  after installation  Repeated bending  flexing or  extreme vibration can cause metal fatigue  DO NOT  repeatedly move appliance for cleaning  once installed     4  AVOID connector contact with foreign objects such as wall studs  electrical wiring   copper or iron pipe  paneling sheet metal  etc  Gas systems should NOT be used as  electrical grounds  Dissimilar metals should be isolated from each other        5  Keep cleaning solvents containing ammonia or chlorine away from uncoated gas  connectors   Figure F  DO NOT store these solutions in closets containing a water  heater or furnace  Chlorine can corrode uncoated stainless steel     6  DO NOT use connectors to make a direct connec   tion to L P  gas containers   Figure G  Connection  MUST be made to the regulator device only     7  DO NOT use connectors on appliances in moving  vehicles such as RV   s  trailers  etc  This does not  include manufactured housing  permanent  residence mobile homes      INSTALLATION        WARNING  DO NOT CONNECT Safety PLUS EXCESS FLOW VALVE DIRECTLY TO  THE APPLIANCE  The Safety PLUS valve must be installed between the gas supply  pipe and the flexible gas connector  If ins
6. s  you will hear a soft    click                  AX WARNING  DO NOT TURN ON APPLIANCE UNTIL ALL  CONNECTIONS ARE LEAK TESTED     9  Leak test all connections with a clear soap and  water solution or leak detection solution  bubbles  will indicate a leak in the connection   Figure L    If a leak is detected  turn off gas supply before  further tightening connections        WARNING  DO NOT USE matches  candles  open  flames or other sources of ignition to leak test  connector or fittings  A spark or flame may ignite  gas leaks potentially causing property damage  and or personal injury including death   Figure M        CAUTION  DO rinse connector with water and towel  dry after leak testing connections  Soap and test  solutions may cause an uncoated connector to  corrode     10  Wait at least 10 minutes to light pilot s  once you  have leak tested all connections and have found no  leaks  to be certain that all vapors have dissipated        WARNING  DO NOT USE motorized equipment or  other sources of combustion to dissipate gas  vapors  Motorized equipment can ignite gas vapors  causing fire or explosion which may result in property damage and or personal  injury including death   Figure N        DANGER  Fuel gases are colorless  tasteless and in its pure state  odorless   They are odorized  rotten egg smell  so that their presence can be detected   LP gases are heavier than air and dissipate slower than natural or manufactured  gases  LP gas  if released in quantity  will acc
7. s input rating of the  appliance must be within the flow capacity range  of the connector  If the Safety PLUS gas  connector is not properly sized to the application   the Safety PLUS connector may not activate in  the event of a gas line rupture or disconnection   If the Safety PLUS gas connector is under sized  for the appliance  may activate prematurely  restricting gas flow during normal operation of  the appliance     GAS APPLIANCE  INPUT RATING    62 500    4  Finally  select the connector with the end fittings  that match the outlet of your manual gas shut off  valve and the gas inlet to the appliance   Figure D        Chart 1  Gas Connector Maximum Flow Capacity    Cas Connector Maximum Flow Capacity    pea  Tare elge       ae   a   oe   e  e       NOTE  All Safety PLUS valves require minimum inlet pressure of 4    W C  and are  rated at a maximum inlet pressure of 1 2 psig   14    W C    Flow rates given  are for 0 6 specific gravity natural gas with an average heating value of 1000  BTU per cubic foot  therefore  1 000 BTU Hr is equal to 1 SCFH  standard cubic  foot per hour  Chart to be used in accordance with the local plumbing codes and  with reference to IAPMO ANSI UPC 1 2003  NFPA 54 ANSI 2223 1   National  Fuel Gas Code     INSTALLATION INSTRUCTIONS  SAFETY PRECAUTIONS     1  Read and follow all installation instructions carefully   When in doubt  call a licensed plumber or your local  gas company     2  DO NOT reuse the gas connector or fittings   The connect
8. talled to the gas inlet of the appliance  the  Safety PLUS valve will not operate        WARNING  DO NOT USE matches  candles  open flames or other sources of ignition  during product installation  A spark or flame may ignite gas vapors causing property  damage and or personal injury including death  Extinguish all pilot lights within 50ft   before proceeding with appliance installation     1  Turn off gas supply at the appliance before discon  OPEN CLOSED    necting old appliance  The manual gas shut off  valve  located near the appliance  is closed and gas  is shut off when valve handle is perpendicular to  the valve body  Figure H   In absence of manual gas  shut off valve near appliance location  gas MUST be  shut off at main valve  before the meter     NOTE  The Fuel Gas Codes require installation of a  manual gas shut off valve in the same room  within  easy reach of the appliance     2  Clean ALL pipe threads with a wire brush and rag to ensure connections are free  of any debris such metal shavings  rust  dirt  oil or water     3  Apply pipe thread sealant to the male pipe threads        CAUTION  DO NOT apply pipe thread sealant or  tape to flare ends of fittings or valves  Figure 1    Sealant and tape will prevent this connection from  sealing properly     4  If not already installed  thread a manual gas shut off   _  valve onto gas stub out  Using one adjustable Fig     wrench to stabilize the gas stub out  wrench tighten  valve with second wrench     5  Inspect the
9. umulate in low lying areas such  as a basement or crawl space     THIS SAFETY PLUS EXCESS FLOW VALVE  included with the connector  IS NOT  DESIGNED TO ACTIVATE IF ANY OF THE FOLLOWING CONDITIONS ARE PRESENT     There are small leaks such as pin hole leaks or lesser leaks caused by cracks  or loose connections that do not increase the gas flow above normal operating  capacity of the appliance     The gas appliance malfunctions or the user fails to shut off gas burners        Fig  M          There is foreign matter  such as pipe thread sealant  lodged in the valve     The manual gas shut off valve is partially opened  or there is a pipe break  or damage that has occurred upstream of the Safety PLUS valve excess flow  valve  that prevents sufficient gas flow through the valve     There is an insufficient gas flow from an improperly sized gas piping system  upstream of the Safety PLUS valve     The gas flow through the valve is in the wrong direction  The excess flow valve  responds to gas flow in one direction only  See product label   The valve must be  installed so that the arrows point in the direction of gas flow     e The Safety PLUS valve is damaged  exposed to fire or improperly installed        WARNING  Replace the Safety PLUS valve if it has been damaged or exposed  to fire     Gas Connector    Excess Flow Valve    BrassCroaft     BrassCraft Mfg    39600 Orchard Hill Place Novi  Michigan 48375 5331      2009  2011 BrassCraft Mfg     TOLL FREE  877 272 7755 FAX  248 305 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Mode d`emploi de la Boîte de Couplage LDG AT  Exakta 36mm Operating Instructions  Inoxpa Prolac HP  Pick-Poke-It2004-07  Agilent 10705A Single Beam Interferometer and Agilent 10704A  Manual - CT Automatismos y Procesos SL  Télécharger le document - Antibes Juan-les-Pins    IBM ServicePac PC966  LevelOne 16-Port Fast Ethernet Switch    Copyright © All rights reserved. 