Home

Solar Infra Systems SH1 Instructions / Assembly

image

Contents

1. Ave Temperature iiid cdd 44 8 F 24 9 C Increase Sept May Max Air Temperature B eee nor f ae Controls Red Absorption Turn the Fan Speed Control Solar InfraRed knob clockwise to increase the Transmission 90 90 fan circulation Start out with Polycarbonate Pane ee woot Staged Collector 45 64sqft azam to operate Knob to Projected Area l l maximum PV Panel 7W 14vdc 7W 14vdc Sun Orientation AC Adapter AC 110 220vac 12 vdc 500ma Collector Material aluminum steel aluminum steel on both sides of a true south More east 4 Plastic Panel UL94v 0 UL94v 0 Materials catches morning solar and west Heater Weight 15s 6 8 kg Trie catches afternoon solar j Watch for roof eves that overhan 1 Based on 80 of solarradiationon90 tilted heater vertical behind South g single glaze window at49 N lattitude 9 months of year Sept to May 20de i 20de and shade the window and heater as 2 RETScreen data NRCan CanmetENERGY NASA solar data g g N at well as trees and buildings that block 3 Retscreen 49 N latitude 123 1 E longitude 4 Underwriter s Laboratories self extinguishing Conforms to window and NZ AYA AX the sun s path wall covering building stds gy om Snecifications subiect to chanae without notice Don t forget to fill out the Warranty Card and the Solar Energy Payback Estimator South or North in the southern hemisphere facing covers 20 degrees WARRANTY TERMS If a defect ar
2. locations The program is a free download at www retscreen net You need Microsoft Office Excel to use the program We normally send you a PDF file of the results of the analysis but we can also send a RETSCreen file to run more comparisons Solar Infra Systems International Ltd 209 19138 26th Avenue Surrey BC V3S 3V7 Canada Toll Free 1 855 535 2056 T 604 535 2056 F 604 535 0681 www solarinfrasystems com email info solarinfrasystems com Issue 1 3 2013 SIS Air Solar Heater Retscreen Performance Estimate IMPORTANT The SIS Consumer Model is designed for interior use inside a single pane south facing window and not for outdoor applications Double pane Low E Triple Pane all reduce the amount of solar heat that enters the window The efficiency of the interior air solar heater will decrease compared the single pane windows The SIS Consumer Solar Air Heater mounted inside the room behind the window glass reverses this heat loss collects the solar heat coming through the glass and heats the air in the room Radiative Conductive Total Compared to Heat Heat Heat Single Pane Indoor Window Construction Loss Loss Loss Heat Loss Glass Btu hr ft2 Btu hr ft2 Btu hr ft2 Reduction Temp F Single Pane Clear Double Pane Clear Double Pane Low E Double Pane Low E Argon Triple Pane Low E Triple Pane Low E Argon Solar Visible Light Spectrum The Solar Heater PY panel that runs the circulation fan operates on the visi
3. works best with a Solar Air Heater Issue 1 3 2013 Thank you for purchasing a Solar Infra Heater Detailed information and a hanging kit is found in the instruction package Please note that this package also contains an A C to D C adapter Please remove all plastic wrap before activating the unit in the sun The unit must be placed on the inside of a south exposed window This unit is not designed for exterior or outdoor installations Other models with waterproof fans are available Efficiency ratings have been measured from behind single pane windows The efficiency will decrease when behind thermo pane or E glass that reduces infra red energy transmission Solar infra can tell you the length of time it will take for this unit to pay back the purchase price in energy savings based on the season your location and local energy costs Please email us at info solarinfrasystems com or call toll free at 1 855 535 2056 The heater may be simply placed on the windowsill leaning against the glass or suspended from the window header with the supplied mounting kit The discharge fan must face the interior of the room Please retain the original shipping carton for a period in case of any issues you may have with our product and contact us directly info solarinfrasystems com Toll free 1 855 535 2056 renee NOOY M M E Jayeay sy JeJog e ULI Set LOH pur Shey g Jc Ul Burzeje apg poi N oov s8q SHJOM Buize D e Duis AjeuipJ
4. 35 2056 oolar Infra Systems Int Ltd Issue 12 12 2012 SIS Air Solar Heater Retscreen Performance Estimate SOLAR PAYBACK ESTIMATOR See What Air Solar Heating Can Do Please fill out this form and we will run a RETScreen analysis for you to show the air solar heating and the cost savings estimate Mail fax or email Name Email Telephone 1 Location Country state prov etc Nearest large City Heating Period example Oct to May Your average inside temperature Do you have a South facing wall roof or direction To sun path shading from trees buildings in season DOO estimated Home Apartment Building Approximate area Number of floors Basement insulated or not Window glaze on south facing side oingle glaze Double glaze oF GO NN o sqM Qoo 9 N e R value for roof and walls Approx age of building Electricity and Heating System Cost of electricity per kilowatt hour Heating fuel gas oil propane etc Cost per unit of heating fuel gal therm GJ liter cuM etc Age of furnace Last serviced Heating system efficiency Have you had an energy audit Send me RETScreen File requires Microsoft Office Excel o OC o CO J Q 0 We use RETScreen to analyze an air solar heating unit or system for your application The program was developed by Natural Resources Canada using NASA solar data The program is used world wide since the 1990 s and has solar data for most world
5. OPERATING INSTRUCTIONS SOLAR THERMAL AIR HEATER Consumer Model SIS C25M 1848 Issue 1 6 2013e Solar Infra Systems International Ltd 209 19138 26 Avenue Surrey BC V3S 3V7 Canada Toll Free 1 855 535 2056 T 604 535 2056 F 604 535 0681 www solarinfrasystems com What is an Air Solar Heater This SIS air solar heater uses the sun s solar energy to heat air through a window in the home apartment cottage boat RV and circulate this heated air in the room This is not a solar PV panel or solar water heater The heater is hung or placed in a south facing closed window inside the room or space to be heated IMPORTANT This SIS solar air heater is designed for interior installation behind a single pane window for best efficiency Double pane low E argon and triple pane will reduce this efficiency to less than 40 to 65 The SIS Solar Air Heater mounted inside r olar Energy the room behind the from the Sun window glass reverses this heat loss collects the solar heat coming through the glass and heats the air in the room Ordinary single glazing works best with an interior Air Solar Heater SIS has a range of exterior mount models Fan recirculates heated air back into the room Solar Collectors that are not affected Heat the by glass obstruction Radiative Conductive Total Compared to Moving Air and are capable of Heat Heat Heat Single Pane Indoor heating an entire Window Construct
6. ble sunlight spectrum Construction type U value R value Solar Infrared Energy W m 2 K BTU h Ff m 2 K W h Fft BTU This Solar U Value 5 2 i i i smissi i d 2 8 0 49 0 36 2 0 collects the 9096 near infrared transmission air filled e i low E LI LI infrared f U Value 2 9 em ue ener Standard Double Glazing mom pane LOW E gy 4296 near infrared transmission Argon filled 1 9 0 33 0 53 3 0 through the ind laze ore Triple pane 24 37 0 48 2 7 window g Double Glazing and Argon Gas 0 to heat 38 near infrared transmission Tinie para Double Glazing with Low E Glass Stal SINGLE Gy a gt ING and circulate air in the 28 near infrared transmission Quadruple pane room U Value 1 1 very low E Krypton filled 0 74 0 13 1 35 23 I Double Glazing with Low E Glass and Argon Gas Quintuple pane 23 near infrared transmission very icwE Xenon tilled 0 51 0 09 1 96 11 1 MAS Ni iE Gu KANG OUTSIDE In house windows the U factor is the rate of heat loss through the glass of the window from inside the house to the outside The heat loss rate depends on the difference between the temperature inside the room and outside the house Double glazing Low E some tints reduce the heat loss through the window The SIS Solar Air Heater mounted inside the room behind the window glass reverses this heat loss collects the solar heat coming through the glass and heats the air in the room Ordinary single glazing
7. ion Loss Loss Loss Heat Loss Glass house For more Btu hr ft2 Btu hr ft2 Btu hr ft2 Reduction Temp F Single Pane Clear Double Pane Clear Double Pane Low E Double Pane Low E Argon Triple Pane Low E Triple Pane Low E Argon The SIS Air Solar Heater Installation Hang or set on the sill in a south facing window The window should be ordinary single glazing Turn the speed control knob to maximum Large glass areas such as solariums can have too much heat loss through the glass to the air outside for this size of SIS air solar heater It may require more heater or a model Please contact us at information call 1 855 535 2056 or email us Window at info solarinfrasystems com Room Air This SIS model air solar heater heats air It is like an electric room convection air space heater except it is operated by the sun s solar 1 energy Hang or set it in a sun facing window or side ways or even upside down and it will 2 maintain heat in a large room or area in the home The heating capacity is equivalent to a than one 150 to 500 watt electric heater depending on the daytime sun and cloud cover The model air solar heater is also transparent and will still let most of the window sunlight into the room Sunlight and a PV panel also operate a fan on the heater The fan draws the room air into the heater and then pulls the air through metal solar energy collectors heated by the sun The solar heated air is recircula
8. ising solely from faulty hardware materials or workmanship appears under proper use of this equipment For defects in hardware materials and workmanship within a period of 12 months from the date of purchase Solar Infra Systems will repair the defect or at its option replace the defective part or parts The main exclusions from the warranty are if the equipment has been 1 Neglected mishandled or inappropriately used or 2 Modified or altered in any way except with the prior approval of Solar Infra Systems Solar Infra Systems is not liable for any consequential loss 1 Solar Infra Systems is not liable to the Buyer for any defect unless the Buyer immediately gives Solar Infra Systems notice in writing or email of the alleged defect with full particulars of the operating conditions under which it became apparent and returns this equipment or relevant part shipping paid to Solar Infra Systems 2 Any items returned to Solar Infra Systems are at Buyer s risk Repaired or replacement items will be despatched shipping paid to the address requested by Buyer 3 Solar Infra Systems total liability relating to the supply of this equipment is limited to the Buyer s purchase price of the product The warranty is given to the Buyer of this equipment from Solar Infra Systems or Solar Infra Systems subsidiaries The warranty cannot be transferred by the Buyer to any other person or company Contact email info solarinfrasystems com Tel Toll Free 1 855 5
9. o WOO eui MU edo ui Jie Su sjeeu pue sseb ay uBnoJuj Buruoo a a E anybnonp Jeou 12 08 SU sjo9 oo sso Je y SIU sesJoA oJ maa N yapa ies sse D MOPUIM y PUIYSq WOO 3y episul een oe ui BE eni pejunoul JoS EeH ly Je OS Jeunsuo SIS 3y zej6 ojbuis DS AB1jauz3 paseu sejos SMODUIM surd mE Pr voneporo eu sumi ed a Duis eu peJeduioo aseajoap JJa Jayeau unaj2eds 3uBr1 eiqisiA 4ejos Jelos JIE JOU Ul eau JO OU9SIOIJIOS SU MOpPUIAA LOB 3 wo0 euegd e dul au siojue JEU Jes IB JOS JO JUNOWe au 3 01 eugedu eonpei Sued d 3 o sued sjqnog uci 3 01 eueg ejqnoq a UE aan suoneoiidde 1o0o0pjno JO jou pue opul eae ie ae Buioer uinos sued ajfuis e apisul asn Jouejul Qqjdue uenonpeg ayiumg avium ajuuma 10 peuDisep s japo Jeuinsuoo SIS sy sse 5 S807 Je8H 80 80 80 uopnoarn suo AOpLI AN Joopu euegejDus yey jea H 23H o paiedwoy e o sAgonpuo aAneipey LNVIUOdNI
10. ted back into the room The fan has a speed control so the air exchange in the room can be set usually to 1 to 1 1 2 hours at up to 75 cubic feet per minute Patented technology and international patents pending larger info solarinfrasystems com and we will help you size the solar heating The Solar Heater can be mounted between the window and a venetian blind Make sure the blind is open enough to allow fan recirculation into the room Use the fan speed control to adjust the room temperature The slower the air flow the higher the outlet temperature because of the increased air retention time in the heater Rooms and home areas usually are planned for 1 to 2 air changes every three hours Turn the knob clockwise to increase the air flow The fan capacity is 75 cubic feet of air per minute Divide this into the volume of the room or heated area and this will show the number of air changes per hour For example Air changes Room 20ft x 15ft x 10 ft high 3000 cubic feet volume Air Changes 3000 cubic ft 75 cu ft min x 60 min hr 66 air changes per hour 2 air changes every 3 hours Cloudy low sunlight or rain conditions may not produce enough Photovoltaic Panel energy on the front of the heater to operate the fan even though there may be enough solar energy for the heater to add 3 4 degrees to the room temperature Use the AC adapter to operate the fan from household power a timer can schedule the fan for day use onl
11. y The cost is minimal For cottages and homes without power an optional large PV panel will be available for increased sensitivity for low sunlight conditions WHAT IS YOUR PAYBACK We use a NASA Government program that calculates the energy savings and heating output in most locations in the world Email your location home area electricity cost per kWh heating fuel and unit cost and we will send you the time payback estimate on the savings in energy by using an air solar heater or fill in form at www solarinfrasystems com Solar Infra Systems Int Ltd Issue 12 12 2012 Solar Infra Systems International Ltd 209 19138 26 Avenue Surrey BC V3S 3V7 Canada Toll Free 1 855 535 2056 SIS Model C25M 1848 Dimensions T 604 535 2056 F 604 535 0681 SPECIFICATIONS www solarinfrasystems com 488mm 19 in S F Peak Efficiency Ave 80 an Ave Max Daily Power Fan j 736 btu hr sqft 2 32 kWhr m2 L BuU Output L Control Window Mounting Single Glaze Single Glaze E Heater Mounting Tilt Vertical 909 Vertical 909 z E in Window E Azimuth Direction 4 Due South 0 Due South E facing Sun Ave Total Annual E E Solar Radiation 3 7mbtu sqft 1 090 kWh m2 3 E Tilted 90 12 mon S E E Total Annual Heating 1201 kWhr ae Delivered 9 mon Coleter IE Air Flow Range 10 75cfm 17 127 m3 hr E oum Noise Level 3295db 3295db me 1 AC Adapter Sun Side Room Side

Download Pdf Manuals

image

Related Search

Related Contents

Supersmoke 1000 取扱説明書  Linx - Blatchford  CineSuite User`s Manual CineSuite Software Package  TERMINAL INTELIGENTE  スズキ株式会-ネ銀電動車いす (ノドン ド2レ型) 野二係る 重大製品事故の  OTRUM Enterprise Reception Web 3.0    Étude de faisabilité d`une consultation en libre-accès au  8051 EVM Manual - Pantech Solutions  Page 1 Page 2 Page 3 Page 4 Page 5 由形ノ~ウを作りま しょ う (焼き  