Home
Vigo VG6011BNCL36WR Instructions / Assembly
Contents
1. THIS EDGE LOOKS OUTSIDE OF THE SHOWER SLIDE TOP OFF TO INSTALL 3 4 SCREW FIG 2 ALUMINUM COVER INSIDE CORNER JOINT CAP OUTSIDE FIG 3 MODEL VG06011 B INSTALLING THE WATER SEAL STRIP TO FRONT FIXED PANEL 1 Clean the front fixed panel 6 edge where the door side seal strip 15 is to be installed with rubbing alcohol 2 SEE FIG 4 3 Verifv that the soft flange of the seal strip faces toward the inside of the shower cabin before seal strip installation 4 Install the seal strip according to the diagram See Note A Leave the extra at the top of the seal strip that is overlapping the glass and cut at finish of install NOTES 1 Ifthe seal strip is not flat and is twisted soak the strip in hot water and press the seal strip back into position 2 Part 15 is reversible and pre cut on top and bottom to fit in proper configuration Cutting finishing is needed but only after fully installing and only at the top of the unit 3 The door magnetic seal strip 11 and the side seal strips 7 will be 10mm shorter than the front glass panel This is to compensate for the depth of the bottom rail The door magnetic seal strip 11 is reversible and will need to be cut at top for best aesthetic approach THIS SIDE MUST LOOK INSIDE THE NOTE A MAKE SURE TO LEAVE A GAP OF 3 8 10MM FROM THE BOTTOM OF THE GLASS MAKE SURE TO LEAVE A GAP OF 3 8 10MM FROM THE BOTTOM OF 5 THIS SIDE MUST
2. B amp C DIMENSIONS WERE MEASURED AFTER SHOWER ENCLOSURE WAS COMPLETELY INSTALLED MODEL VG06011 WARNING WE STRONGLY RECOMMEND THAT A LICENSED PROFESSIONAL INSTALL THIS SHOWER CABIN AND INCLUDE THE ASSISTANCE OF A SECOND PERSON TO INSTALL THE DOOR UNIT INSTALLATION OF THE SHOWER DOORS BY AN INEXPERIENCED PERSON MAY RESULT IN GLASS BREAKAGE AND CONSEQUENTLY CAUSE PERSONAL INJURY OR DEATH BEFORE STARTING Compare items on your invoice with what you have received Carefully review the Packing List on page 2 If any items are missing contact Vigo Industries at 1 866 591 7792 nes TOOLS Square and or Phillips 1 and 2 screwdriver Flat head screwdriver Electric drill plus 1 32 3 32 1 8 and 1 4 drill bit depending on wall Level Measuring tape Pencil non permanent Clear silicone caulking Utility knife WARNING e Handle fragile items with care to prevent injury or material damage e Glass on panels and doors is tempered glass and must never be cut to prevent personal injury IMPORTANT e Fiberglass or acrylic construction might not be sufficiently strong enough to support the shower door enclosure You should use the wood framing studs from behind the face edge of the stall to provide a secure mounting to the door Apply a bead of silicone between the walls and base of the stall e For optimum performance you should install the shower door perfectly level on a level surface Failure to do so will lea
3. Accidental scratches or stains will rarely show If they do show they can be easily removed with a liquid automobile polish N IMPORTANT Do NOT use abrasive cleaners scrapers metal brushes or any items products that would scratch and or dull surface Do NOT allow surface to come into contact with acetone nail polish remover dry cleaning solution lacquer thinner gasoline or any other similar product MAINTENANCE INSTRUCTIONS FOR THE SHOWER CABIN AND DOOR PANEL A If you are experiencing water build up in the top portion of the rail it is recommended to drill small holes on the top inside portion Space holes every 6 8 Stay within 3 from the end of the rail SEE FIG 16 OUTSIDE OUTSIDE 15 MODEL VG06011 VIGO VIGO INDUSTRIES LLC VIGO SHOWER ENCLOSURE LIMITED LIFETIME WARRANTY EFFECTIVE JANUARY 1 2010 VIGO offers the following limited warranty on each of its Shower Enclosure products the Product and the components thereof This warranty extends only to the original owner or end user for personal household use For commercial uses additional limitations apply VIGO warrants the structural glass component of the Product to be free from defects in workmanship and materials under normal use and service for the period commencing from the initial date of purchase by the owner or end user contractor or builder from VIGO or an authorized VIGO dealer through the lifetime of the original owner o
4. S 98039 ws WS Sal 20 PLASTIC ANCHOR 98037 22 HEX SCREW COVER 96040 o 24 ALLEN KEY PACK MISC ER a WITH HARDWARE AND WITHOUT SHOWER BASE FULLY INSTALLED MODEL DIM A DIM B DIM C HEIGHT 5 SIDE GLASS PANEL 97003 6 FRONT GLASS 14 DOOR 97010 PANEL 97004 36 X 48 34 1 8 23 3 4 73 3 8 33 1 8 x71 5 8 21 1 4 x71 5 8 23 5 8 x70 3 4 36 X 36 34 1 8 341 8 227 8 733 8 33 1 8 x71 5 3 10 1 8 x71 5 8 22 7 8 x70 3 4 32 X 48 30 1 4 36 X 48 36 1 8 48 1 8 23 3 4 79 1 4 33 1 8 x71 5 8 21 1 4 x71 5 8 28 5 8 x70 3 4 36 X 36 36 1 8 36 1 8 22 7 8 79 1 4 33 1 8 x71 5 8 10 1 8 x71 5 8 22 7 8 x70 3 4 46 5 SIDE GLASS PANEL 97003 6 FRONT GLASS 14 DOOR 97010 PANEL 97004 23 3 4 73 3 8 29 1 4 x71 5 8 21 1 4 x71 5 8 23 5 8 x70 3 4 32 X 40 30 1 4 38 1 4 22 7 8 73 3 8 29 1 4 x71 5 8 14 1 8 x71 5 8 22 7 8 x70 3 4 32 X 32 30 1 4 30 1 4 19 3 4 73 3 8 29 1 4 x71 5 8 9 1 2 x71 5 8 19 3 4 x70 3 4 WITH HARDWARE AND WITH CORRESPONDING VIGO BRAND BASE FULLY INSTALLED 32 X 48 32 3 8 48 1 8 23 3 4 79 1 4 29 1 4 x71 5 8 21 1 4 x71 5 8 23 5 8 x70 3 4 32 X 40 32 3 8 40 1 4 22 7 8 79 1 4 29 1 4 x71 5 8 14 1 8 x71 5 8 22 7 8 x70 3 4 32 X 32 32 3 8 32 3 8 19 3 4 79 1 4 29 1 4 x71 5 8 9 1 2 x71 5 8 19 3 A x70 3 4
5. 8 10MM FROM THE BOTTOM OF THE GLASS HEX SCREW 18 K INSIDE OF SHOWER ar l Hex screw GLASS PANEL GASKET VIEW FROM THE TOP FIG 5 MODEL VG06011 MAKE SURE TO LEAVE A GAP OF 3 8 10MM FROM THE BOTTOM OF FIG 5A THE GLASS HINGE INSTALLATION Clean the glass surface on the front glass panel 6 where the hinges 10 are to be installed with rubbing alcohol Place gaskets on each side of the front glass panel 6 Position hinges on the front glass panel 6 SEE FIG 6 Place shim s as needed between the glass and the hinge on the bottom The metal should not rest on the glass SEE FIG 7 screw the hinges to the front glass panel with the hex key supplied FRONT GLASS PANEL 6 THIN GASKETS SEAL STRIP 15 VIEW FROM INSIDE FIG 6 HINGE 10 HINGE 10 INSIDE VIEW FRONT GLASS FRONT GLASS PANEL 6 PANEL 6 PVC SHIM CLEAR FIG 7 PVC SHIM MODEL VG06011 4 5 6 WARNING DOOR PANEL INSTALLATION REQUIRES TWO OR MORE PEOPLE TO ASSIST INSTALLING THE DOOR Clean the door 14 glass surfaces where the hinges 10 are to be installed with rubbing alcohol Place magnetic seal strip 11 to the door panel 14 SEE FIG 4 on page 7 The magnetic side should be facing the inside and the clear side be facing the outside Make sure the seal is level with the bottom of the panel Do not install
6. THE GLASS LOOK INSIDE THE CABIN 6 6 15 14 FIG 4 SEAL STRIP INSTALLATION DIAGRAM MODEL VG06011 C So IM INSTALLING THE FRONT amp SIDE GLASS PANEL ka Arrange glass to the preferred configuration SEE FIG 1A on page 410 These instructions are for a left corner installation Select the door opening location on the shower cabin Install the seal strip 7 to the wall side of the front glass panel 6 ISEE FIG 4 on page 7 Screw in the glass support 8 to the front glass panel 6 using the hex key supplied making sure to slide it back as far as possible from the glass before vou tighten The part that connects to the wall should be facing in SEE FIG 5 Be sure to use washers on both sides of the panel Place the front glass panel 6 onto the bottom rail 9 Use the level to position the front glass panel correctly Make sure the seal strip 7 is against the wall Mark holes on the wall for the mounting screws Remove the front glass panel Drill holes into the respective marks and insert plastic anchors 21 inside them Not necessary if installing into studs Studs are the preferred means of installation anchors can pull out of the wall causing property damage and bodily harm Replace the front glass panel back onto the bottom rail and screw it to the wall with the with 1 5 8 screws 18 Repeat steps 1 through 8 for side glass panel 5 SEE FIG 5A GASKETS MAKE SURE TO LEAVE A GAP OF 3
7. is installed by fully insured licensed professionals Vigo strongly recommends that such licensed professionals have experience in the installation of bathroom and kitchen products Installation of certain products including without limitation glass products i e shower doors and glass sinks by an inexperienced person may result in glass breakage and consequently cause personal injury or death VIGO is not liable for personal injuries or deaths to any persons or for any direct special incidental or consequential damage loss of time loss of profits inconvenience incidental expenses labor or material charges or any other costs resulting from the use of the product or equipment or pertaining to the application of the present warranty or resulting from the removal or replacement of any product or element or part covered by this warranty EXCEPT AS OTHERWISE PROVIDED ABOVE VIGO MAKES NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE OR COMPLIANCE WITH ANY CODE In any case VIGO cannot be held liable for any amount over and above the purchase price paid for the Product by the owner end user contractor or builder Commercial Limitations In addition to the above conditions and limitations the warranty period for products installed for commercial applications or used in commercial ventures is one 1 year from the initial date of purchase by the owner end user contractor or
8. the handle first this is dangerous and may cause the glass to break Install the top hinge first for safety and ease of install Position the door onto the hinges Hold securely in place using shims The seal 15 may get stuck between the two panels of glass Pull the seal out of the groove using your fingers and nothing sharp making sure not to damage the seal Tighten allen key screws Install the hinges as illustrated SEE FIG 8 Use the hex key supplied Adjust hinge so the gaps are equal at top and bottom and pull door panel away from front panel 6 to allow the door to swing freely without crimping seal strip 15 Lift door panel to be level with hinge panel Use PVC shims provided to hold firmly in place NOTE You may need to add more than one shim per hinge as glass hole openings vary during production PVC shims prevent the door from sagging due to gravity and the weight of the door Never install without shims this can cause the glass to break causing property damage and bodily harm HINGE 10 OUTSIDE OF THIN GASKET THIN GASKETS SEAL STRIP 14 u FRONT GLASS PANEL 6 THIN GASKET INSIDE OF THE CABIN HEX SCREW VIEW FROM THE TOP VIEW FROM INSIDE FIG 8 10 MODEL VG06011 INSTALLING THE SIDE 8 FRONT PANEL SUPPORT Install the support assembly 4 onto the side glass panel 5 and the front fixed panel 6 approximately two thirds away from the wall Use hex key to tigh
9. E HANDLE H INSTALLING THE HANDLE METAL WASHER P DOOR PANEL 1 Assemble the door handles 13 to CLEAR e the door 14 SEE FIG 12 WASHER tok mo _ A WHITE TUBE O OUTSIDE Wi ANNEES GLASS SUPPORT THREADED SCREW FIG 12 12 MODEL VGO6011 APPLVING THE SILICONE Applv clear silicone caulking to the inside between the wall and side seal strip Repeat for the other side SEE FIG 13 Apply clear silicone caulking to the inside between the side panel bottom and the bottom rail Apply clear silicone caulking around the inside perimeter of the bottom rail Apply silicone where the corner joints meet the base rails Apply clear silicone caulk to the seal strip connections of the door bottom seal strip and the door magnetic seal strip SEE FIG 14 ee UE J INSTALLING HEX SCREW COVERS 1 Install hex screw covers 22 to the hex screws that mount the hinges wall connectors and glass supports IMPORTANT e WAIT 24 HOURS BEFORE USING SHOWER e DO NOT ALLOW WATER TO DIRECTLY HIT DOOR SEAL STRIPS 13 MODEL VG06011 EP VG06011 LEFT DOOR 3 K or O O or FP VG06011 RIGHT DOOR 14 MODEL VG06011 CLEANING INSTRUCTIONS FOR THE SHOWER CABIN AND DOOR PANEL A DOW Use mild liquid household cleaners to keep metal surface bright and clean Rinse well and drv with a clean cloth Remove dust with a soft damp cloth Use rubbing alcohol to clean and remove grease oil paint and ink
10. VIGO VIGO INDUSTRIES INSTALLATION GUIDE FOR SHOWER ENCLOSURE MODEL VG06011 SAFETY PRECAUTIONS This Installation Guide uses the following symbols to indicate important information Always observe the instructions indicated by these symbols WARNING Instructions that if ignored could result in death or serious personal injury caused by incorrect handling or installation of the product These instructions must be observed for safe installation N CAUTION The instructions for the following unit is based off of the Vigo brand shower base The instructions can not be provided for any other installation other than that of the Vigo brand The warranty will be voided if the following was not performed properly IMPORTANT Maintenance and other important non personal injury and non material damage instructions or statements that should be observed It is highly advised to dry fit the unit prior to any installation INSTALLATION INSTRUCTIONS FOR STANDING SHOWER CABIN OWNER S MANUAL PLEASE READ INSTRUCTIONS BEFORE PROCEEDING Packing List 1 Wall connector 2pc 2 Longer Structural arm 1pc 3 Shorter Structural arm 1pc 4 Support assembiv 2pc 5 Side glass panel 1pc 6 Front glass panel with hinge slots 1pc 7 Side seal strip 2pc 8 Glass support 4pc 9 Bottom rail 2pc Hinge 2pc Door magnetic seal strip 2pc Bottom corner joint 1pc Handle assembly 1pc Door 1pc Door
11. ations This warranty shall not apply to instances of incorrect operating procedures breakages or damages caused by fault through improper installation carelessness abuse misuse misapplication improper maintenance or alteration of the Product as well as chemical or natural corrosion accident fire flood an act of God or any other casualty Avoid abrasive cleaners steel wools and harsh chemicals as these will scratch damage and or dull the product and or finish and void this warranty The owner end user of the Product covered by the present warranty is entirely responsible for its proper installation and any applicable plumbing or electrical wiring VIGO neither installs nor supervises the installation nor hires a contractor for this purpose consequently VIGO cannot be held responsible for any default breakage or damages caused thereby or resulting thereof either directly or indirectly The owner end user must provide access to the components of the Product as described in the installation guide so that VIGO can execute the warranty specified herein If such access is not available all expenses to provide said access will be the responsibility of the owner end user This warranty does not apply to Products that have not been installed or operated in accordance with instructions supplied by VIGO and all applicable rules regulations and legislation pertaining to such installations This warranty does not apply unless the VIGO Product
12. builder from an authorized dealer VIGO is not responsible for loss of use or profit under any circumstances If the product is used as a display the warranty period begins when the product is placed on display This warranty gives the owner end user specific legal rights The owner end user may also have other rights which can vary from one state or province to another Warranty Service In order to obtain service provided under this warranty during regular business hours contact the dealer or distributor who sold the unit or contact VIGO directly VIGO will provide the warranty service described above when the following conditions have been met the failure is of the nature or type covered by the warranty the user has informed an authorized VIGO Agent or VIGO s warranty service department representative of the nature of the problem during the warranty period conclusive evidence e g proof of purchase or installation is provided to the foregoing by the user proving that the failure occurred or was discovered within the warranty period an authorized independent service person or company representative has been permitted to inspect the product during regular business hours within a reasonable time after the problem was reported by the user VIGOs warranty obligation shall be discharged upon tender of replacement or repair The customer s refusal to accept the tender terminates VIGO s warranty obligations Certain models are pending approval Certif
13. d to water leakage and potential property damage e When installing use heavy duty gloves e FOR THE MATTE GLASS MODELS Oil secretions from skin will leave transparent spots on the matte side of the glass Use a degreasing non abrasive cleaner to remove these secretions The same will happen if you get silicone on the matte glass Use a silicone remover to remove these stains IMPORTANT THE CLEAR GLASS MODEL HAS A REVERSIBLE DOOR AND CAN BE INSTALLED TO THE RIGHT OR LEFT SIDE THE TEXTURED SIDE OF THE MATTE GLASS UNIT SHOULD ALWAYS BE INSTALLED ON THE OUTSIDE OF THE UNIT SEE CONFIGURATION DIAGRAM BELOW 5 14 6 6 14 SIDE GLASS DOOR PANEL FRONT GLASS FRONT GLASS DOOR PANEL SIDE GLASS PANEL PANEL PANEL PANEL FIG 1A GLASS CONFIGURATION DIAGRAM J DOOR DOOR RIGHT CORNER LEFT CORNER 4 INSTALLATION MODEL VGO6011 INSTALLATION VIGO PREPARATION STEPS TO FOLLOW BEFORE INSTALLATION 1 Remove the plastic layer from the base border if needed Do NOT remove the plastic layer off the plastic platform of the base Properly apply silicone to the wall and base joints 3 Make sure to read corresponding base instructions carefully prior to install on the Vigo Brand Shower Door System Failure to do so can cause water leakage and bodily harm N IMPORTANT e o prevent damage to the finish you should protect the shower cabin bottom with a cardboard protector before beginning the installation e Ensure that there is sufficient str
14. ication may be ended by VIGO or certification agencies without notice 16 MODEL VG06011
15. r end user VIGO warrants the hardware components of the Product to be free from defects in workmanship and materials under normal use and service for a period of two 2 years from the initial date of purchase by the owner or end user contractor or builder from VIGO or an authorized VIGO dealer VIGO warrants the seal strip components of the Product to be free from defects in workmanship and materials under normal use and service for a period of one 1 year from the initial date of purchase by the owner or end user contractor or builder from VIGO or an authorized VIGO dealer Subject to the Warranty Service provision below any product reported to the authorized dealer or to VIGO as being defective within the warranty period will be repaired or replaced with a product of equal value at the option of VIGO This warranty extends to the original owner or end user and is not transferable to a subsequent owner Neither the distributor authorized VIGO dealer nor any other person has been authorized to make any affirmation representation or warranty other than those contained in this warranty Any affirmation representation or warranty other than those contained in this warranty shall not be enforceable against VIGO or any other person VIGO reserves the right to modify this warranty at any time it being understood that such modifications will not alter the warranty conditions applicable at the time of sale of the products in question Limit
16. side seal strip 2pc 1 of each is extra 20 Door bottom seal strip 2pc 1 of each is extra Phillips screw 1 1 8 2pc Hex screw 1 5 8 4pc Phillips screw 3 4 5pc Plastic anchor green 7pc Plastic anchor white 4pc Hex screw cover 16pc Clear PVC shims 1 pack Allen key pack 1 pack GLASS THICKNESS 3 8 NOTE INSTALLATION MUST BE DONE BY A QUALIFIED GLASS INSTALLER D MODEL VG06011 VIGO 1 WALL CONNECTOR 98007 2 LONGER STRUCTURAL ARM 98068 3232 98068 3636 98068 3240 98068 3248 98068 3648 3 SHORTER STRUCTURAL ARM 98069 3232 98069 3636 98069 3240 98069 3248 98069 3648 4 SUPPORT ASSEMBLY 98009 5 SIDE GLASS PANEL 97003 32 97003 36 97003 48 6 FRONT GLASS PANEL 97004 32 97004 36 97004 40 97004 48 7 SIDE SEAL STRIP 96001 8 GLASS SUPPORT 98010 A amp l 9 BOTTOM RAIL D 95002 32x32 95002 32x40 95002 32x48 95002 36x36 95002 36x48 10 HINGE ASSEMBLY N 98011 11 DOOR MAGNETIC SEAL STRIP 96011 12 BOTTOM CORNER JOINT 94004 SF 13 DOOR HANDLES 98012 15 98012 18 14 DOOR 97010 32 97010 36 97010 40 97010 48 15 DOOR SIDE SEAL STRIP 96006 16 DOOR BOTTOM SEAL STRIP 96004 o 17 PHILLIPS SCREW 1 1 8 98035 19 PHILLIPS SCREW 3 4 98033 21 PLASTIC ANCHOR 98038 23 CLEAR PVC SHIM MISC 18 HEX SCREW 1 5 8
17. ten the screws SEE FIG 9 Install one wall connector 1 and the longer structural arm 2 to the support assembly 4 on the side glass panel 5 Make sure it s level Install the second wall connector 1 and the shorter structural arm 3 to the support assembly 4 on the front fixed panel 6 Mark the holes on the wall for the mounting screws for the wall connector Remove the support assembly Drill holes into respective marks and put plastic anchors 20 in them Not necessary if installing into studs Replace wall connector to proper position Screw it in to the wall with 1 1 8 screws 17 Slide the structural arms 2 3 into the wall connectors 1 Tighten all set screws SEE FIG 10 Repeat Steps 1 through 7 to install the other support assembly to the other glass panel OR FRONT PANEL FINISHED VIEW FIG 10 11 MODEL VGO6011 VIGO G INSTALLING PRE CUT BOTTOM DOOR SEAL STRIP 1 Clean the door glass panel 14 edge where the door bottom side seal strip 16 is to be installed with rubbing alcohol 2 SEE FIG 11 3 Verify that the soft flange of the seal strip faces toward the inside of the shower cabin before seal strip installation 4 Install the seal strip according to the diagram NOTE Ifthe seal strip is not flat use a hair dryer to apply minimal heat and press the seal strip back into position OUTSIDE OF INSIDE OF THE CABIN THE CABIN FIG 11 INSID
18. uctural support behind the shower wall to hold the weight of the shower door If there is insufficient support then reinforce the shower walls with wooden studs prior to shower door installation SEE FIG 1 CAUTION e GASKETS NEED TO BE IN BETWEEN ALL GLASS AND METAL CONTACT FAILURE TO DO SO CAN LEAD TO BREAKAGE AND POTENTIAL BODILY HARM MODEL VG06011 INSTALLATION STEPS Viso A INSTALLING THE BOTTOM RAIL Remove the aluminum cover from the front piece of the bottom rail by sliding it out Remove top of the corner joint Slide the bottom corner joint 12 onto the bottom rail 2 pieces 9 SEE FIG 2 Align the bottom rail and corner joint to the desired position on the shower base Make sure the A and B distances are correct see page 3 for A and B distances Prior to drilling dry fit everything making sure that everything is straight level and plum Pre drill for sinkers and tap sinkers Cut excess sinker off with hacksaw or sharp blade Dip screws in silicone SEE FIG 2A Screw corner joints and rails down Silicone tops of screws seal the bottom rail with clear silicone caulk and center its sides to the base Clip the aluminum cover to the front piece of the bottom rail making sure the lower side faces the inside of the shower SEE FIG 3 silicone the underneath portion of the corner joint cap and place it on the corner joint SEE FIG 3 THIS EDGE LOOKS 7 INSIDE OF THE SHOWER N
Download Pdf Manuals
Related Search
Related Contents
Handleiding CoaguChek XS PPC - Barbacena - Instituto Federal do Sudeste de Minas Gerais RILEVATORE GAS CON ALLARME MANUALE DI INSTALLAZIONE Manuale GEOtank Using COIN-OR Solvers with Microsoft Windows Application Note: Vector Control of a 3-Phase AC Induction MANUALE D`USO - Bayer Diabetes Care PACSystems* RX3i CPU IC695CPU315 Copyright © All rights reserved.