1.    Do Not Remove Knockouts In  The Outlet Box     Make wiring connections as indicated above   White from fan to white from remote marked  N  Orange from fan to Orange from remote  marked Light up  Blue from fan to blue from  remote marked down light  Black from fan to  Black from remote marked L  White from  house to white from remote marked ACN   Black from house to Black from remote  marked AC L  Connect all green ground wires  to Ground wire from House     Install 1 x 100 watt JD E 11 halogen bulb  Do  not touch bulb surface as oily residue from skin  can cause the bulb to explode  Bulb included   WARNING  Over lamping the fan will re   sult in the fan lights shutting down  until the proper wattage of bulbs are  installed  Reset the lights by turning off  the wall switch  breaker or by remote  Re   place bulbs with the correct wattage bulbs   turn the power on                 2011 Monte Carlo Fan Company    3 2 2012                Install glass to fan using the 3 ball    Install glass to fan  screws provided     Remove cover by snaping off from top or bot   tom  Remove battery cover  Install 12V battery  into wall remote  Duracell MN21   Eveready  A23   GP 23A all 12V Attach cover of remote by  placing over buttons and snap the battery cover  in place     Place face plate over battery compartment and  buttons  Place remote over 2 pins on front cover    Attach cover of remote by placing over 4 pins and  Snaping into place              Attach front cover to wall control  wi
2.   prominent warning device  such as a tag  to the service panel     Be cautious  Read all instructions and safety information before installing your new fan  Review the accompanying assembly diagrams   When cutting or drilling into wall or ceiling  do not damage electrical wiring and other hidden utilities     Make sure the installation site you choose allows the fan blades to rotate without any obstructions  Allow a minimum clearance of 7 feet  from the floor to the trailing edge of the blade     WARNING  To Reduce The Risk Of Fire  Electric Shock  or Personal Injury  Mount To Outlet Box Marked    Acceptable for Fan Support of  15 9 kg  35 Ibs  or less    And Use Mounting Screws Provided With The Outlet Box     CAUTION  For Compliance with Local Codes and Regulations  If Installing The Secondary Support Safety Cable in the U S   Do Not Re   move Knockouts In The Outlet Box  Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to  the building structure  or the ceiling joist      WARNING  To reduce the risk of personal injury  do not bend blade holders during installation to motor  balancing or during cleaning  Do  not insert foreign object between rotating blades     Attach the mounting bracket using only the hardware supplied with the outlet box   WARNING  To reduce the risk of fire or electric shock  this fan must be installed with an isolating wall control switch     WARNING  To reduce the risk of fire or electric shock  this fan
3.  If you have more than one fan  with remote  You can set the dip switches to differ   ent positiosns to have seperate control     Make wire connections to power source using  wire nuts provided  Make sure that no filiments  are outside of the wirenut  After making the  wire connections  the wires should be spread  apart with the grounded conductor and the  equipment grounding conductor on one side of  the outlet box and ungrounded conductor on the  other side of the outlet box        Carefully lift fan assembly onto mounting  bracket  Rotate fan so that the notch on the ball  engages the ridge in the mounting bracket  This  will allow hands free wiring     Install remote receiver by sliding into opening in  the mounting bracket  Make sure that the dip  switches on the transmitter and the receiver are  set to the same positions     Raise the canopy up and align the  two holes in the canopy with the two  holes in the hanger bracket  Secure  with two screws provided        Sa cable installation    2 Soe  3    lag lock  screw washer    For Canadian installation and for USA fan and light  kit combinations over 35 Ibs  in both flush and  downrod modes the safety cable must be installed  into the house structure beams using 3    lag  screws  washers and lock washers provided  Make  sure that when the safety cable is fully extended  the lead wires are longer than the cable and no  stress is placed on the lead wires    Note  If Installing The Secondary Support Safety  Cable in the U S
4.  should only be used with fan speed control part no  UC7067RC manufac   tured by Rhine Electronic Co   Ltd     WARNING  To reduce the risk of fire or electric shock  do not use this fan with any solid state fan speed control device  or variable speed  control     If this unit is to be installed over a tub or shower  it must be marked as appropriate for the application   Never place a switch where it can be reached from a tub or shower     The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit   s operation  Follow the heating  equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association  NFPA   and the  American Society for Heating  Refrigeration and Air Conditioning Engineers  ASHRAE  and the local code authorities     CAUTION  To Reduce the Risk of Electric Shock  Disconnect the electrical supply circuit to the fan before installing the light kit   All set screws must be checked and tightened where necessary before installation     Tools Required for Assembly  not included   Electrical Tape  Phillips Screwdriver  Pliers  Safety Glasses   Stepladder and Wire Strippers     Customer Service  800 969 3347    Customer Service Center  7400 Linder Ave   Skokie  IL 60077   www montecarlofans com                   2011 Monte Carlo Fan Company 3 2 2012          iaf jee j       m p       hnala    MAAA ML SSA    Before you begin installing the fan  Switch power off  at Service pa
5. MEOE NE Berane    CEILING FAN COMPANY       SATR44XXD L Series Fan    UL Model No    AC 40448       Attach sales receipt to this card and retain as your proof of purchase    DATE OF PURCHASE  RETAILER NAME           MODEL NUMBER  RETAILER ADDRESS           To register your fixture  please visit our website www montecarlotans com                14 3kgs    CXS US 31 5 lbs  LISTED Total fan weight with light kit                      Cautions and Warnings    WARNING  TO REDUCE THE RISK OF FIRE  ELECTRIC SHOCK  OR INJURY TQ PERSONS  OBSERVE THE FOLLOWING  READ AND SAVE THESE INSTRUCTIONS    Installation work and electrical wiring must be done by qualified person s  in accordance with applicable codes and standards  ANSI NFPA  70 1999   including fire rated construction     Use this unit only in the manner intended by the manufacturer  If you have any questions contact the manufacturer     After making the wire connections  the wires should be spread apart with the grounded conductor and the equipment grounding conductor  on one side of the outlet box and ungrounded conductor on the other side of the outlet box  The splices  after being made  should be  turned upward and pushed carefully up into the outlet box     WARNING  Before you begin installing the fan  servicing or cleaning unit  Switch power off at Service panel and lock service disconnecting  means to prevent power from being switched on accidentally  When the service disconnecting means cannot be locked  securely fasten a
6. h  Showed the most improvement and by trial and error move the clip in and out along the blade  to find the position which most improves the wobble  E  Remove the clip and discard  Once the  exact position is determined  place a weight on bottom of the metal blade holder on its center   line  Press the weight firmly to ensure it is firmly attached to the blade holder  Add more  weight as needed to balance        4  If light does not work  1 Check wire from fan to make sure it is connected to hot wire from house   2 Check for loose or disconnected wires in fan switch housing   3 Check for loose or disconnected wires in light kit     4 Check for faulty light bulbs   WARNING  Over lamping the fan will result in the fan lights shutting down  until the proper wattage of bulbs are installed     Reset the lights by turning off the wall switch  breaker or by remote  Replace bulbs  with the correct wattage bulbs  turn the power on     CAUTION  Make sure main power is turned off before entering switch housing   WARNING  Before attempting to replace the fuse make sure the main power is turned    off to the fan  Replace only with a 3 amp fuse   Fuse is inside the canopy on the blue  and orange wires to remote receive  push and twist the cap to open the fuse case                        2011 Monte Carlo Fan Company 3 2 2012    Mar 2012 New format  May 2013 Update for CUL regulation    
7. nel and lock service disconnecting  means to prevent power from being switched on ac   cidentally  When the service disconnecting means  cannot be locked  securely fasten a prominent warn   ing device  such as a tag  to the service panel     Install 4 x 15 watt cande  pedo shape bulbs     Ed  Tighten both yoke set screws and  lock nuts to further secure downrod        box is properly installed to the house structure   To reduce the risk of fire  electric shock  or per   sonal injury  mount to outlet box or supporting  system acceptable for fan support     Mounting must support at least 35 Ibs      Loosen screw holding half ball and  remove pin from downrod  Thread  wires and safety cable through down   rod and insert downrod into motor  yoke     Install upper glass over downrod  onto fan body        Insert clevis pin    Install the Mountiing Bracket to the    Outlet box  Use only the screws  provided with the outlet box     through yoke and  downrod and secure with keeper pin    see inset     Install canopy over downrod  Cau   tion  Replace pin and ball onto down   rod              2011 Monte Carlo Fan Company    3 2 2012                Tighen set screw loosened in step 5         Remote Receiver Dip switches      Set dip switches on the Remote Transmitter and  Remote Receiver to the same settings  This must  be done so the units will communcate properly  If  you have other fans you can set to control from  one transmitter by setting both receivers the same  as the transmitter
8. tallation  or wiring  In  some cases  these installation errors may be mistaken for defects  If you experience any faults  please check this Trou   ble Shooting Chart  If a problem cannot be remedied  or you are experiencing difficulty in installation  please call our  Customer Service Center at the number printed on your parts list insert sheet    Warning  Before servicing or cleaning unit  Switch power off at Service panel and lock service disconnecting  means to prevent power from being switched on accidentally  When the service disconnecting means can   not be locked  securely fasten a prominent warning device  such as a tag  to the service panel     Trouble Suggested Remedy    1  If fan does not start  1 Check main and branch circuit fuses or circuit breakers   2 Check line wire connections to fan and switch wire connections in switch housing   3 Check to make sure the dip switches from the transmitter and receiver are set on the same  frequency   CAUTION  Make sure main power is turned off    2  If fan sounds noisy  1 Check to make sure all screws in motor housing are snug  not over tightened    2 Check to make sure the screws which attach the fan blade holder to the motor are tight   3 Check to make sure wire nut connectors in switch housing are not rattling against each other  or against the interior wall of the switch housing     CAUTION  Make sure main power is turned off before entering switch housing     4 Some fan motors are sensitive to signals from Solid State 
9. th screws provided  Snap battery  cover in place                   Attach blade assembly to arms from  motor housing using screws and  washers provided  Tighten screws se   curely     WALL MOUNT INSTALL       Install wall control unit to outlet box  using machine screws provided              2011 Monte Carlo Fan Company    3 2 2012       Cer          she  fap  Remote Control Transmitter Features     FAN REVERSE   Press once to  change direction of         LED LIGHT MEDIUM SPEED the fan Fanmust be  running to reverse   HIGH SPEED  LOW SPEED    FAN OFF SETTING    PLIGHT ON OFF SET    Turns fan off only  SEER ON KER    TING AND DIMMER   Press and hold to dim  light infinitively     DOWNLIGHT ON OFF  SETTING AND DIMMER   Press and hold to dim  light infinitely     FAN SPEED Depress  1 dot    for low speed   2 dots    for medium or  3 dots    for  high  To turn fan off press square        LIGHT DIMMER To turn light on  press light dimmer once quickly  To turn off   press once quickly while light is on  To dim light hold down button    light dimmer       The light will cycle from bright to dim to bright until button is released  Light will  maintain last setting if turned off     FORWARD REVERSE Depress rev button allow a few seconds for remote to  change rotation direction with fan running              2011 Monte Carlo Fan Company          3 2 2012             Trouble Shooting    If you have difficulty operating your new ceiling fan  it may be the result of incorrect assembly  ins
10. variable speed controls  DO NOT  USE a Solid State variable speed control    5 Allow  break in  period of 24 hours  Most noises associated with a new fan will disappear  after this period     3  If fan wobbles  1 Make sure that the ridge of the canopy engages the notch in the downrod ball    2 Check that all blades are screwed firmly into blade holders    3 Check that all blade holders are tightened securely to motor    4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box  and junction box is mounted firmly to ceiling joist    5 Dynamic balancing involves    counter weighting     By using a small weight opposite to the  point of wobble  you can in almost all cases eliminate the wobble  The procedure requires  much trial and error  and a certain amount of patience to achieve the correct position of the  counterweight  A  Determine which fan speed causes the most wobble  This will almost always  be the highest speed  B  Turn the fan off  Select any one blade and place the balance clip half  way between the blade tip and blade holder  on the rear edge of the blade  Caution  Be care   ful to stay clear of the blades when running  If the clip is not secure  injury may re   sult from the clip flying off  C  Turn the fan on  Observe if the wobble is better or worse   Turn the fan off and move the clip to the next blade  Do the same for all blades and note on  which blade the clip improves the wobble the most  D  Place the clip on the blade whic
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
MicroLogic PLC 1500 System    Penclic Numpad N2  Fujifilm Astia 100 F 135/36  Radiowecker  Aastra BluStar 8000i Desktop Media Phone - telefonanlage    HP LaserJet M1522 MFP Series User Guide - Hewlett  Canon DR-5010C Owner's Manual  Manuale Operativo del Paranco Servoassistito    Copyright © All rights reserved. 