Home

Hampton Bay 68353 Use and Care Manual

image

Contents

1. Close to Ceiling Mounting f Remove the decorative canopy bottom cov Figure 9 Remove three of the six screws and lock 4 Place the rubber gasket over the remaining three screws route the wires exiting the top Remove the mounting bracket from the of the fan motor through the ceiling cano canopy by loosening the four screws on the py over the collar at the top of the motor top of the canopy Remove the two non Figure 9 slotted screws and loosen the slotted screws 5 This will enable you to remove the hanger bracket Figure 5 Align the mounting holes with the holes in the motor and fasten using the three screws and lock washers removed in step 3 er from the canopy by depressing the three 6 Tighten the mounting screws securely studs Figure 7 WARNING FAILURE TO COMPLETELY TIGHTEN THE THREE SCREWS IN STEP 6 COULD RESULT IN FAN LOOSENING AND POSSIBLY FALLING Figure 9 Figure 7 washers every other one securing the re inforcing plate to the top of the fan motor housing Figure 8 Figure 8 Installing Fan to the Outlet Box WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR OTHER PERSONAL INJURY MOUNT FAN ONLY TO AN OUTLET BOX MARKED AC CEPTABLE FOR FAN SUPPORT AND USE THE MOUNTING SCREWS PROVIDED WITH THE OUTLET BOX 1 Pass the 120 volt supply wires through the center hole in the ceiling mounting bracket as shown in Figure 10 2 Install the ceiling moun
2. customer IMPORTANT NOTE To ensure warranty service if ever necessary please register your fan at gpwarranty com You must present a copy of the original purchase receipt to obtain warranty service G P WARRANTY SERVICE CENTER INC WARRANTY SECTION 1951 N W 22nd STREET FORT LAUDERDALE FLORIDA 33311 Attach receipt here for easy location San Marino de 36 Ventilador de techo de Hampton Bay Funci n de reversa de 3 velocidades para confort y ahorro durante todo el a o Inclinaci n de aspa m s pronunciada para obtener un mayor flujo de aire Instalaci n de montaje triple Accu arm para una instalaci n f cil y precisa PREGUNTAS PROBLEMAS O PIEZAS FALTANTES Antes de volver a tu tienda local de The Home Depot llama a nuestro Equipo de Servicio al Cliente al 1 877 527 0313 o visita www homedepot com Por favor usa como referencia el N de SKU 666 834 acero cepillado o UPC 82392 876531 acero cepillado Gracias por comprar este ventilador de techo de Hampton Bay Este producto se ha fabricado con las normas de seguridad y calidad m s altas El acabado de este ventilador es resistente a la intemperie pero con el tiempo exhibir un desgaste y decoloraci n naturales 2 Indice Normas de seguridad 00 1 C mo desempacar el ventilador 2 C mo instalar el ventilador 3 C mo operar el ventilador 10 Cuidado del ventilador 11 Soluci n
3. FALL HOOK MUST PASS FROM INSIDE TO OUTSIDE OF CANOPY LOCKING SLOTS OF CEILING CANOPY ARE PROVIDED ONLY AS AN AID TO MOUNTING DO NOT LEAVE FAN ASSEMBLY UNATTENDED UNTIL ALL FOUR CANOPY SCREWS ARE EN GAGED AND FIRMLY TIGHTENED WARNING WHEN USING THE STANDARD BALL DOWN ROD MOUNTING THE TAB IN THE RING AT THE BOTTOM OF THE MOUNTING BRACKET MUST REST IN THE GROOVE OF THE HANGER BALL FAILURE TO PROPERLY SEAT THE TAB IN THE GROOVE COULD CAUSE DAMAGE TO WIRING WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE A SOLID STATE SPEED Connect the fan motor white wire to the supply white neutral wire using a wire nut Figure 12 SUPPLY CIRCUIT CONTROL WITH THIS FAN IT WILL PERMANENT LY DAMAGE THE ELECTRONIC CIRCUITRY 3 Connect the fan motor black wire to the sup ply hot wire using a wire nut Figure 12 Making the Electrical 4 Connect the blue wire for the light kit to the C onne cti ons black household supply wire outst 5 Turn wire nut connections upward spread REMEMBER to disconnect the power If ing them apart so the green ground and Pl Green you feel you do not have enough electrical white wires will be on one side of the outlet Grounding wiring knowledge or experience have your fan box and the black and blue wires will be on Lee installed by a licensed electrician the other side and push into the outlet box Follow the steps below to c
4. Un flujo de aire hacia arriba mueve el aire c lido lejos del techo como se muestra en la Figura 17 Esto te permite fijar tu unidad de calefacci n en una configuraci n m s baja sin afectar tu comodidad Figura 16 Za 27 A Figura 17 C mo operar el ventilador 10 Como Cuidar del Ventilador Aqui tienes algunas sugerencias para el manten imiento de tu ventilador 1 Debido al movimiento natural del ventila dor algunas conexiones pueden aflojarse Verifica las conexiones de soporte sopo rtes y accesorios de aspas dos veces al a o Verifica que est n seguros No es necesario desmontar el ventilador del techo Limpia tu ventilador con frecuencia para que luzca como nuevo a pesar de los a os No uses agua al limpiar esto puede da ar el motor o la madera o causar descargas el ctricas Usa solamente un cepillo suave o trapo sin pelusas para evitar ara ar el aca bado El revestimiento est sellado con laca para minimizar la decoloraci n u opacidad Advertencia Aseg rate de que la cor riente est apagada antes de limpiar el ventilador Puedes aplicar una fina capa de pulimento para muebles a la madera para una mayor protecci n y belleza Cubre los ara azos peque os con una leve aplicaci n de lustra dor para calzado Tu ventilador no necesita lubricaci n El motor tiene cojinetes de bola sellados per manentemente lubricados Il Soluci n de problemas Problema El ventilador
5. cal Code and local electrical codes Electrical installation should be performed by a qualified licensed electrician WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control de vice CAUTION To reduce the risk of personal injury use only the screws provided with the outlet box WARNING W___1_ TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR PERSONAL IN JURY MOUNT FAN TO OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT WITH THE SCREWS PROVIDED WITH THE OUTLET BOX The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 pounds Use only UL Listed outlet boxes marked FOR FAN SUPPORT The fan must be mounted with a minimum of 7 feet clear ance from the trailing edge of the blades to the floor Do not operate reversing switch while fan blades are in mo tion Fan must be turned off and blades stopped before re versing blade direction Avoid placing objects in path of the blades 9 10 AS 13 To avoid personal injury or damage to the fan and other items be cautious when working around or cleaning the fan Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable for most cleaning After making electrical connections spliced conductors should be turned upward and pushed carefully up into outlet box Th
6. en el centro de cada aspa a un punto 3 Deslizael kit de luces con caja de interruptor 5 Desliza la caja del interruptor hacia arriba en el techo Mide esta distancia como se y aseg ralo al soporte negro usando los tres tornillos que se quitaron en el paso 1 4 Levanta la pantalla en el soporte de pantalla y gira de izquierda a derecha para fijarla en su sitio Repite para la pantalla restante 5 Con la electricidad desconectada inserta las bombillas CFL de 9W incluidas en los portabombillas del kit de luces Max 9 vatios PRECAUCI N RIESGO DE DESCARGA EL CTRICA LOS CONECTORES SUMINISTRADOS EN UN y aseg rala al soporte negro usando los tres tornillos que se quitaron en el paso 1 muestra en la figura 15 Rota el ventilador hasta que se posicione la siguiente aspa para su medici n Repite para cada aspa Las desviaciones de la medici n deben estar dentro de 1 8 Enciende el ventilador por 10 minutos 3 Usa el kit de compensaci n de aspas adjunto si sigues notando oscilaci n Punto en Opci n de kit sin luces VENTILADOR DE TECHO PARA DAR ENERG A A A A UN KIT DE LUCES OPCIONAL NO SE DEBER N 1 Quita los tres tornillos de montaje en el QUITAR A MENOS QUE SE INSTALE UN KIT DE soporte negro debajo del motor LUCES DE INMEDIATO Y SE DESCONECTE LA ELECTRICIDAD ANTES DE QUITAR EL CONECTOR E INSTALAR EL KIT DE LUCES el techo 2 Desconectar los dos conectores de cable para el kit de luces Quita
7. of the blades Measure from a point 4 Insert the shade into the shade holder and moved in step 2 on the center of each blade to the point on the turn it clockwise to lock in place Repeat for Connect the wires existing the bottom of the aia A n T o the remaining shade motor with the fan control system which is is ee for measurement Repeat for 5 With the power off insert the 9W CFL light inside the switch cap by connecting the each blade Measurement deviations should bulbs included into the light kit sockets Max 9 watts molded adaptor plugs together Slide the switch cap up and secure the switch cup to the black bracket using the three screws that were removed in step 1 within 1 8 Run the fan for 10 minutes 3 Use the enclosed Blade Balancing Kit if the blade wobble is still noticeable Touching Ceiling CAUTION RISK OF ELECTRIC SHOCK THE CONNEC TORS PROVIDED IN A CEILING FAN FOR SUP PLYING POWER TO AN OPTIONAL LIGHT KIT SHOULD NOT BE REMOVED UNLESS A LIGHT mS i 3 KIT WILL BE IMMEDIATELY INSTALLED AND THAT POWER SHOULD BE TURNED OFF PRIOR TO CONNECTOR REMOVAL AND LIGHT KIT IN STALLATION Figure 15 9 WARNING TO REDUCE THE RISK OF PERSONAL INJURY DO NOT BEND THE BLADE HOLDERS WHILE INSTALLING BALANCING THE BLADES OR CLEANING THE FAN DO NOT INSERT FOREIGN OBJECTS BETWEEN ROTATING BLADES NOTE WAIT FOR FAN TO STOP BEFORE REVERSING T
8. 666 834 San Marino 36 in Ceiling Fan Owner s Manual San Marino Ventilador de Techo de 0 91 m Manual del Propietario 36 San Marino Ceiling Fan by Hampton Bay 3 Speed Reverse Function for Year Round Comfort and Savings Steeper Blade Pitch for Greater Air Movement Tri Mount Installation Accu Arm for Accurate and Easy Installation QUESTIONS PROBLEMS MISSING PARTS Before returning to your local Home Depot please call our Customer Service Team at 1 877 527 0313 or visit www homedepot com Please reference your SKU 666 834 brushed steel or UPC 82392 876531 brushed steel Thank you for purchasing this Hampton Bay ceiling fan This product has been manufactured with the highest standards of safety and quality The finish of this fan is weather resistant but over time will naturally weather and fade Table of Contents Safety Rules cssccssssccsssssesscees 1 Unpacking Your Fan 000 2 Installing Your Fan ssseeee 3 Operating Your Fan sc0s00 10 Care of Your Fan ssscsesseseeee 11 Troubleshooting scccscssscesees 11 Specifications ccsscssssssesseese 12 Warranty Information 13 READ AND SAVE THESE INSTRUCTIONS To reduce the risk of electric shock insure electricity has been turned off at the circuit breaker or fuse box before be ginning All wiring must be in accordance with the National Electri
9. ACER LAS CONEXIONES EL CTRICAS PIES C B PESO PESO PIES TAMANO VELOCIDAD VOLTIOS AMPERIOS VATIOS RPM X MIN NETO BRUTO C B oats a 12 54 14 19 lat ia Estas son las medidas aproximadas No incluyen ni el amperaje ni el vataje consumido por el kit de luces Distribuido por Home Depot U S A Inc 2455 Paces Ferry Rd N W Atlanta Georgia 30339 N mero del proveedor 11688 Especificaciones 12 Garant a limitada de por vida de Hampton Bay Garant a de por vida para el motor Hampton Bay garantiza de por vida a partir de la fecha de compra por el comprador original que el motor del ventilador no presenta defectos de fabricaci n ni de material desde la fecha de salida de la f brica Hampton Bay tambi n garantiza por un per odo de uno a o a partir de la fecha de compra por el comprador original que todas las dem s piezas del ventilador sin incluir ninguna aspa de vidrio o acr lico no presentar n ning n defecto de fabricaci n o de material desde el momento de su salida de la f brica Acordamos reparar todos los defectos del tipo antes mencionado sin cargo alguno o a nuestra discreci n reemplazar el producto por un modelo de calidad comparable o supe rior si el producto se devuelve a Hampton Bay Para obtener una garant a de servicio debe presentar una copia del recibo como comprobante de compra Todos los costos de retiro y reinstalaci n del producto son su responsabilidad Da os a cualquiera de las piez
10. BUCI N No operar el interruptor de reversa mientras las aspas del ventila dor est n en movimiento El ventilador debe estar apagado y las aspas detenidas antes de invertir la direcci n del movimiento Evita colocar objetos en la trayectoria de las aspas 1 Normas de seguridad 9 10 11 12 13 Para evitar lesiones o da os al ventilador y otros objetos ten cui dado al trabajar cerca del ventilador o al limpiarlo No usar agua o detergentes para limpiar el ventilador o las aspas En general a la hora de limpiar bastar con usar un pa o seco o ligeramente humedecido Despu s de concluir con las conexiones el ctricas debe voltear los conductores empalmados hacia arriba y empujarlos con cuidado hacia dentro de la caja de distribuci n Los cables deben estar sepa rados con el cable a tierra y el conductor a tierra del equipo hacia uno de los lados de la caja de distribuci n Los diagramas el ctricos son s lo una referencia Los kits de luces no empaquetados con el ventilador deben estar aprobados por UL y marcados como apropiados para ser usados con el modelo de venti lador a instalar Los interruptores deber n estar clasificados por UL como de Uso General Consulta las instrucciones adjuntas a los kits de luces e interruptores para obtener informaci n sobre el ensam blado adecuado Usa bombillas 9W CFL m ximo incluidas Todos los tornillos deben revisarse y reajustarse cuando sea necesario a
11. CHO S LO SON UNA AYUDA PARA HACER ls d P aa inde bae Aseg rate de que la pesta a sobre el cas ERES SR o pa E pa a orig oe quillo de soporte de montaje encaje bien JAYEYNYETHSf SMVAN Wye Wry Vell nels incluidas entre el soporte de montaje y la dentro de la ranura de la bola de soporte FUMA caja el ctrica Nota que el lado plano del Figura 11 JEN Y APRIETEN FIRMEMENTE soporte de montaje esta hacia la caja el c trica figura 10 3 Ajusta firmemente los dos tornillos de ADVERTENCIA montaje y 4 ADVERTENCIA CUANDO USES EL MONTAJE DE TUBO BA PRECAUCION EL GANCHO COMO SE MUESTRA EN LA FIG JANTE Y BOLA EST NDAR LA PESTA A EN CUANDO MONTES EL VENTILADOR EN UN TECHO INCLINADO DEBES USAR EL M TODO DE MONTAJE CON TUBO BAJANTE Y BOLA EST NDAR ASEG RATE DE QUE LAS RANU RAS DEL SOPORTE DE MONTAJE EST N EN EL LADO INFERIOR DESLIZANDO EL SOPORTE DE MONTAJE DESDE ARRIBA HACIA ABAJO URA 11 SOLAMENTE ES PARA SOSTENER EL VENTILADOR MIENTRAS SE CONECTAN LOS CABLES SI NO SE CUELGA COMO SE MUES TRA EN LA FIGURA 11 PUEDE ROMPERSE EL GANCHO Y EL VENTILADOR SE CAER EL GANCHO DEBE PASAR DE ADENTRO HACIA FUERA DE LA CUBIERTA EL ARO EN LA PARTE INFERIOR DEL SOPORTE DE MONTAJE DEBE ENCAJAR EN LA RANURA DE LA BOLA DE SOPORTE SI NO ENCAJA CORRECTAMENTE SE PUEDE DA AR EL CABLEADO 6 ADVERTENCIA _ un cable a tierra verde desde el soporte de PARA REDUCIR EL RIESGO DE INCENDIO O montaje de te
12. Figure 2 Provide Strong lt Support Ceiling lt lt Mounting Plate Recessed Outlet Box Figure 3 Note You may need a longer downrod to maintain proper blade clearance when install ing on a steep sloped ceiling The maximum angle allowable is 30 If the canopy touches downrod remove the decorative canopy bottom cover and turn the canopy 180 before attaching the canopy to the mounting bracket Outlet Box Figure 4 To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 4 available at your Hampton Bay retailer Installing Your Fan 3 Hanging the Fan REMEMBER to tum off the pow er Follow the steps below to hang your fan properly NOTE This ceiling fan is supplied with two types of hanging assemblies the standard ceiling installation using the downrod with ball and socket mounting and the close to ceiling mounting The close to ceiling mounting is recommended in rooms with less than 8 foot ceilings or in areas where additional space is desired from the floor to the fan blades When using standard downrod installation the distance from the ceiling to the bottom of the fan blades will be approximately 12 inches The close to ceiling installation reduces the distance from the ceiling to the bottom of the fan blades to approximately 8 inches Once you have de
13. HANGER BALL FAILURE TO PROPERLY SEAT THE TAB IN THE GROOVE COULD CAUSE DAMAGE TO WIRING WARNING LOCKING SLOTS OF CEILING CANOPY ARE PROVIDED ONLY AS AN AID TO MOUNTING DO NOT LEAVE FAN ASSEMBLY UNATTENDED UNTIL ALL FOUR CANOPY SCREWS ARE EN GAGED AND FIRMLY TIGHTENED 1 Align the locking slots of the ceiling canopy with the two screws in the mounting bracket Push up to engage the slots and turn clock wise to lock in place Immediately tighten the two mounting screws firmly 2 Install the remaining two mounting screws into the holes in the canopy and 1 tighten firmly Attaching the Fan Blades NOTE Your fan blades are reversible Select the blade side finish that best accentuates your decor Pre attached rubber pad Figure 13 Attach blade to blade bracket using the screws provided as shown in Figure 13 Please note that the rubber washers are pre attached to the blade bracket Insert a screw into the bracket Repeat for the two remain ing screws 3 You may now proceed to attaching the fan blades CLOSE TO CEILING MOUNTING 1 Carefully unhook the fan from the mount ing bracket and align the locking slots of the ceiling canopy with the two screws in the mounting bracket Push up to engage the slots and turn clockwise to lock in place Immediately tighten the two mounting screws firmly 8 2 Tighten each screw securely 3 Fasten the blade assembly to the motor by inserting the alig
14. HE DIRECTION OF BLADE ROTATION Turn on the power and check the operation of the fan The pull chain controls the fan speeds as follows 1 pull High 2 pulls Medium 3 pulls Low and 4 pulls Off Speed settings for warm or cool weather depend on factors such as room size ceil ing height number of fans and so on The side switch controls the direction for ward switch up or reverse switch down Warm weather Forward A downward air flow creates a cooling effect as shown in Figure 16 This allows you to set your air conditioner on a higher setting without affecting your comfort Cool weather Reverse An upward air flow moves warm air off the ceiling are as shown in Figure 17 This allows you to set your heating unit on a lower setting with out affecting your comfort 10 Operating Your Fan rae wae Figure 16 a O A D Figure 17 SP Care of Your Fan Here are some suggestions to help you maintain your fan 1 Because of the fan s natural movement some connections may become loose Check the support connections brackets and blade attachments twice a year Make sure they are secure It is not necessary to remove fan from ceiling Clean your fan periodically to help maintain its new appearance over the years Do not use water when cleaning this could damage the motor or the wood or possibly cause an electrical shock Use only a soft brush or lint free cloth t
15. MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BE FORE YOU ATTEMPT TO MAKE ANY REPAIRS REFER TO THE SECTION MAKING ELECTRICAL CONNECTIONS Care of Your Fan amp Troubleshooting 11 FAN SIZE SPEED VOLTS AMPS WATTS EEE so 12 54 14 19 These are approximate measures They do not include Amps and Wattage used by the light kit Distributed by Home Depot U S A Inc 2455 Paces Ferry Rd N W Atlanta Georgia 30339 Vendor number 11688 12 Specifications Hampton Bay Lifetime Limited Warranty Lifetime Warranty on Motor Hampton Bay warrants the fan motor to be free from defects in workmanship and material present at time of shipment from the factory for a lifetime after the date of purchase by the original purchaser Hampton Bay also warrants that all other fan parts excluding any glass or acrylic blades to be free from defects in workmanship and material at the time of shipment from the factory for a period of one year after the date of purchase by the original purchaser We agree to correct such defects without charge or at our option replace with a comparable or superior model if the product is returned to Hampton Bay To obtain warranty service you must present a copy of the receipt as proof of purchase All costs of removing and reinstalling the product are your responsibility Damage to any part such as by accident or misuse or improper installation or by affixing any accessories is not covered by this w
16. arranty Because of varying climatic conditions this warranty does not cover any changes in plated finishes including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life when protected from varying weather conditions A certain amount of wobble is normal and should not be considered a defect Servicing performed by unauthorized persons shall render the warranty invalid There is no other express warranty Hampton Bay hereby disclaims any and all warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law The duration of any implied warranty which cannot be disclaimed is limited to the time period as specified in the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you Hampton Bay shall not be liable for incidental consequential or special damages arising out of or in connection with product use or performance except as may otherwise be accorded by law Some states do not allow the exclusion of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties Shipping costs for any return of product as part of a claim on the warranty must be paid by the
17. as como resultado de accidentes in stalaci n o uso incorrectos o debidos a la instalaci n de cualquier accesorio no est n cubiertos bajo esta garant a Debido a que las condiciones clim ticas pueden variar esta garant a no cubre ning n cambio en el acabado revestido incluyendo xido picaduras corrosi n manchas o descascara miento Los acabados de bronce de este tipo tienen una vida til m s prolongada cuando se protegen de las condiciones clim ticas cambiantes Es normal cierta oscilaci n y no se considerar una falla Cualquier servicio t cnico conducido por personas no autorizadas anular la garant a No hay ninguna otra garant a expresa Mediante la presente Hampton Bay se exime de cualquier garant a incluyendo pero sin limitarse a aquellas de comercializaci n e idoneidad para un fin particular de acuerdo a lo contemplado por la ley La duraci n de cualquier garant a impl cita que no se pueda eximir est limitada al per odo de tiempo especificado en la garant a expl cita Algunos estados no permiten limitaciones a la duraci n de la garant a por consiguiente la limitaci n anterior puede no aplicarse a su caso Hampton Bay no ser responsable por da os directos indirectos o especiales que resulten o deriven del uso o rendimiento del producto excepto en casos en que lo estipule la ley Algunos estados no permiten la exclusi n o limitaci n de da os directos o indirectos por lo que la limitaci n o exclusi
18. cadena del kit de luces para halar kit de compen saci n de aspas C mo Desempacar el Ventilador 2 Herramientas necesarias Destornillador Phillips destornillador plano llave ajustable escalera de tijera y cortacables Opciones de Montaje Si no hay una caja el ctrica lee las siguientes instrucciones Desconecta la energia retirando los fusibles o apagando los cortacircuitos Asegura la caja de distribuci n directamente a la estructura del edificio Usa sujetadores y materiales de construcci n adecuados La caja el ctrica y su soporte deben sostener comple tamente el peso en movimiento del ventilador al menos 35 libras No uses cajas de dis tribuci n pl sticas ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO DESCARGA ELECTRICA O LESIONES PER SONALES MONTA EL VENTILADOR SOLO SO BRE UNA CAJA ELECTRICA MARCADA COMO APROBADA COMO SOPORTE DE VENTILA DOR Y USA TORNILLOS DE MONTAJE QUE VIENEN CON LA CAJA EL CTRICA LAS CAJAS ELECTRICAS UTILIZADAS COMUNMENTE PARA EL SOPORTE DE ARTICULOS DE ILUMINACION PUEDEN NO SERVIR COMO SOPORTE DE VEN TILADOR Y TAL VEZ DEBAN REEMPLAZARSE EN CASO DE DUDA CONSULTA A UN ELECTRI CISTA CALIFICADO Las figuras 1 2 y 3 son ejemplos de diferentes formas de montar la caja de distribuci n distribuci n Figura 1 Caja de distribuci n Figura 2 3 C mo instalar el ventilador Placa de montaje en el techo Caja el ctrica empotrada Figu
19. cho ya que no se usa el ensam CIRCUITO DE SUMINISTRO DESCARGA ELECTRICA NO UTILICES ESTE ble de tubo bajante y bola VENTILADOR CON NINGUN DISPOSITIVO DE O CONTROL DE VELOCIDAD DE ESTADO SOLIDO 2 Conecta el cable blanco de motor del ven ____ Conductor ME Porn ONGO SE BANATA DE tilador al cable blanco de energ a neutro a tierra usando una tuerca de cable Figura 12 C mo hacer las 3 Conecta el cable negro en el motor del ven Caja el ctrica J tilador al cable de suministro de energ a conexiones el ctricas positivo usando una tuerca de cable Fig ua Cable terminal RECUERDA desconectar la electricidad Si mete ul a tierra verde crees que no tienes suficiente experiencia o 4 Conecta el cable azul para el kit de luces al Tierra al conocimientos en cableado el ctrico contrata a cable negro del circuito de la casa tubo bajante las electricista con licencia para que instale el 5 Voltea hacia arriba las conexiones de tuerca ventilador de cable separ ndolas para que el cable Sigue estos pasos para conectar tu ventilador a tu blanco y el verde a tierra est n en un lado circuito dom stico Usa las tuercas de conexi n de la caja el ctrica y el cable azul y el negro de cables que vienen con tu ventilador Asegura est n del otro lado y emp jalos dentro de la los conectores con cinta aislante Aseg rate de caja el ctrica que no existan conexiones o cables sueltos 1 Conecta el conductor a tierra del cable de 120 voltio
20. cided which ceiling installation you will use proceed with the following instructions Where necessary each section of the instructions will note the different procedures to follow for the two types of installation 4 Standard Ceiling Mounting 1 Remove the mounting bracket from the canopy by loosening the four screws on the top of the canopy Remove the two non slotted screws and loosen the slotted screws This will enable you to remove the mounting bracket Loosen but Do Not Remove Figure 5 2 Route the wires exiting the top of the fan motor through the canopy and then through the ball downrod assembly Figure 6 3 Loosen but do not remove the 2 set screws on the collar on the top of the mo tor housing 4 Align the holes at the bottom of the down rod with holes in the collar on top of the motor housing Figure 6 Carefully insert the bolt through the holes in the collar Pin in Locked Motor Wires in Position Ball Downrod Assembly Ceiling Canopy Locking Pinx Motor Collar Cover Bolt Sy Motor Collar Figure 6 and downrod Be careful not to jam bolt against the wiring inside the downrod In sert clevis pin and bend to ensure security as noted in the circle inset of Figure 6 5 Tighten the two screws on top of the fan motor firmly Figure 6 WARNING FAILURE TO PROPERLY INSTALL LOCKING PIN AS NOTED IN STEP 4 COULD RESULT IN FAN LOOSENING AND POSSIBLY FALLING
21. cuenta que los tornillos del motor est n en el sopo rte del aspa figura 14 6 Repita los pasos 1 3 para las aspas restantes ADVERTENCIA RETIRALOS TOPES DE GOMADEL MOTOR EN LA PARTE INFERIOR DEL VENTILADOR ANTES DE INSTALAR LAS ASPAS O PROBAR EL MOTOR Almohadilla de goma preinstalada Figura 13 Figura 14 8 A 3 3 Con la tuerca estriada del interruptor de el mismo peso El siguiente procedimiento C mo instalar el kit velocidad y los dos tornillos del interruptor corregir en gran medida la oscilaci n del de luces de reversa retirados en el paso 2 vuelve Ventilador Verifica despu s de cada paso RECUERDA desconectar la electricidad a montar el conjunto del condensador e 1 Verifica que todas las aspas y tornillos de los F interruptores en la caja del interruptor extra soportes de aspas est n seguros 1 Quita los tres tornillos de montaje en el 2 L ia del bl 4 i soporte negro debajo del motor 4 Une los enchufes con adaptadores ge fe ay Or E TORPO SMAS ie OSET ACION moldeados para conectar los cables que del ventilador se deben a que las aspas no 2 Conecta los cables que salen del fondo salen del fondo del motor al sistema de est n a un mismo nivel Verifica este nivel del motor con el kit de luces al unir los control del ventilador ubicado dentro de la seleccionando un punto en el techo sobre la enchufes con adaptadores moldeados caja del interruptor punta de una de las aspas Mide desde un i punto
22. de problemas 11 Especificaciones cscccccsssesseee 12 Informaci n de garantia 13 LEE LAS INSTRUCCIONES Y GUARDALAS Para disminuir el riesgo de descarga el ctrica asegurate de que la electricidad ha sido apagada en el cortacircuitos o la caja de fus ibles antes de comenzar la instalaci n Todo el cableado debe cumplir con el C digo Nacional de Elec tricidad y con los c digos locales de electricidad La instalaci n el ctrica debe ser hecha por un electricista certificado y calificado ADVERTENCIA Para reducir el riesgo de incendio o descarga el ctrica no utilices este ventilador con ning n dispositivo de con trol de velocidad de estado s lido PRECAUCI N Para disminuir el riesgo de lesiones f sicas usa s lo los tornillos provistos con la caja de distribuci n La caja de distribuci n y estructura de soporte deben montarse de forma segura y tener capacidad para sostener de manera confiable un m nimo de 35 libras Usa solamente cajas el ctricas aprobadas por UL marcadas como PARA SOPORTE DE VENTILADOR El ventilador debe ir montado con un m nimo de 7 pies de sepa raci n entre el borde trasero de las aspas y el piso ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO DESCARGA EL CTRICA O LESIONES PERSONALES MONTA EL VENTILADOR SOBRE UNA CAJA EL CTRICA MARCADA COMO APROBADA COMO SOPORTE DE VENTILADOR Y USA TORNILLOS DE MONTAJE QUE VIENEN CON LA CAJA DE DISTRI
23. dor Figura 6 ADVERTENCIA SI NO INSTALAS CORRECTAMENTE EL PASA DOR DE CIERRE SEGUN LO INDICADO EN EL PASO 6 SE PUEDE AFLOJAR Y POSIBLEMENTE SE CAIGA EL VENTILADOR 4 Montaje cerca del techo 1 Retira el soporte de montaje de la cubierta aflojando los cuatro tornillos en la parte su perior de la cubierta Quita los dos tornillos sin ranura y afloja los tornillos ranurados Esto te permitir quitar el soporte de mon taje Figura 5 2 Retira la cubierta inferior decorativa de la cubierta oprimiendo los tres pernos Figura 7 E T Cubierta Quitar inferior am Figura 7 3 Retira tres de los seis tornillos y arandelas de seguridad alternados que sujetan el col lar n del motor a la parte superior de la car casa del motor Figura 8 5 4 Coloca la junta de goma sobre los otros tres tornillos inserta los cables que salen por la parte superior del motor del ventilador a trav s de la cubierta sobre el collar n antes mencionado Figura 9 5 Alinea los orificios de montaje con los ori ficios en el motor y asegura con los tres tor nillos y arandelas de seguridad retiradas en el paso 3 Figura 9 6 Ajusta los tornillos de montaje correcta mente ADVERTENCIA SI NO AJUSTAS CORRECTAMENTE LOS TRES TORNILLOS SEG N LO INDICADO EN EL PASO 6 SE PUEDEN AFLOJAR Y POSIBLEMENTE SE CAIGA EL VENTILADOR Collar n del motor Tornillo y arandela de cie
24. e instalaci n sigue con las siguientes instrucciones Cuando sea necesario cada secci n de las instrucciones indicar los diferentes procedimientos a seguir para los dos tipos de instalaci n Montaje de techo est ndar 1 Retira el soporte de montaje de la cubierta aflojando los cuatro tornillos en la parte superior de la cubierta Quita los dos tor nillos sin ranura y afloja los tornillos ra nurados Esto te permitir retirar el soporte de montaje Aflojar pero no quitar Figura 5 2 Pasa los cables que salen por la parte su perior del motor del ventilador a trav s de la cubierta y luego a trav s del ensamblado de tubo bajante y bola Figura 6 3 Afloja sin quitarlos los 2 tornillos en el collar n ubicado en la parte superior de la carcasa de motor 4 Alinea los orificios en la parte inferior del tubo bajante con los orificios en el collar n de la parte superior de la carcasa Figura 6 Inserta con cuidado el perno en los ori ficios del collar n y el tubo bajante Evita apretarlo contra el cableado dentro de la Cables del motor Posici n de cierre del pasador Ensamblado de tubo bajante y bola Pasador tipo Cubierta del horquilla f RNA del motor Perno Collar n del motor Figura 6 varilla Inserta el pasador tipo horquilla y d blalo como medida de seguridad como lo muestra la Figura 6 5 Aprieta firmemente los dos tornillos en la parte superior del motor del ventila
25. e la cubierta y aprieta firmemente 3 Ahora puedes colocar las aspas del ventilador MONTAJE CERCA DEL TECHO 1 Con cuidado desengancha el ventilador del soporte de montaje y alinea las ranuras de cierre de la cubierta del techo con los dos tornillos en el soporte de montaje Alza para enganchar las ranuras y gira de izquierda a derecha para trabar en su sitio Ajusta con firmeza los dos tornillos de montaje 2 Instala los dos tornillos de montaje restant es en los orificios de la cubierta y aprieta firmemente 3 Ahora puedes proceder a montar las aspas del ventilador ADVERTENCIA LAS RANURAS DE CIERRE DE LA CUBIERTA DEL TECHO S LO SIRVEN DE AYUDA DURANTE LA INSTALACI N NO DEJES SIN SUPERVISI N EL ENSAMBLADO DEL VENTILADOR HASTA QUE LOS CUATRO TORNILLOS DE LA CUBIERTA SE FIJEN Y SE AJUSTEN FIRMEMENTE C mo montar las aspas del ventilador NOTA Las aspas de tu ventilador son revers ibles Elige el acabado del aspa que mejor resalte tu decoraci n 1 Fija el aspa a su soporte con los tornillos provistos seg n se muestra en Figura 13 Observa que las arandelas de goma est n fijadas en el soporte del aspa Inserta el tornillo en el soporte Repite para los otros dos tornillos Aprieta todos los tornillos de manera firme HB 010 Ajusta el brazo del aspa al motor insertando el poste de alineaci n dentro de la ranura de la parte inferior del motor y ajustando los tornillos del mismo Por favor ten en
26. e wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box Electrical diagrams are for reference only Light kits that are not packed with the fan must be UL Listed and marked suit able for use with the model fan you are installing Switches must be UL General Use Switches Refer to the instructions packaged with the light kits and switches for proper assem bly Use 9W CFL bulbs max included All set screws must be checked and retightened where neces sary before installation WARNING TO REDUCE THE RISK OF PERSONAL INJURY DO NOT BEND THE BLADE BRACKETS ALSO REFERRED TO AS FLANGES DURING ASSEMBLY OR AFTER INSTALLATION DO NOT INSERT OBJECTS IN THE PATH OF THE BLADES WARNING PLEASE REMOVE RUBBER MOTOR STOPS ON THE BOTTOM OF THE FAN BEFORE INSTALLING BLADES OR TESTING MOTOR Safety Rules 1 Unpack your fan and check the contents You should have the following items 1 Fan Motor Assembly 6 Slide On Mounting Bracket 2 Canopy and Mounting Hardware 3 Blades 5 7 Light Kit Fitter 4 Blade Bracket Set 5 8 Shade with motor screws pre installed 9 Decorative Motor Collar Cover 5 Ball Downrod Assembly 10 CFL Bulb 11 Extra Switch Cap Cover IMPORTANT THIS PRODUCT AND OR COMPONENTS ARE COVERED BY ONE OR MORE OF THE FOLLOWING U S PATENTS 5 947 436 5 988 580 5 971 573 6 010 306 6 039 541 6 046 416 AND OTHER PATENTS PENDING 2 U
27. la tuerca estriada del interruptor de velocidad y dos tornillos Equilibrar las aspas del interruptor de reversa para retirar el conjunto del condensador e interruptores de Todas las aspas se agrupan por peso Como la caja del interruptor las maderas naturales var an en densidad el ventilador puede oscilar aunque las aspas tengan 9 Figura 15 ADVERTENCIA PARA REDUCIR EL RIESGO DE LESIONES PER SONALES NO DOBLAR LOS SOPORTES DE LAS ASPAS DURANTE LA INSTALACION COMPEN SACION DE LAS ASPAS O LIMPIEZA DEL VEN TILADOR NO INSERTES OBJETOS EXTRANOS ENTRE LAS ASPAS EN FUNCIONAMIENTO NOTA ESPERA A QUE SE DETENGA EL VENTILADOR ANTES DE INVERTIR LA DIRECCI N DE GIRO DE LAS ASPAS Enciende la electricidad y verifica el fun cionamiento del ventilador El interruptor de cadena controla las velocidades del ven tilador de la siguiente manera 1 vez Alto 2 veces Medio 3 Bajo y 4 Apagado Las configuraciones de velocidad para clima c lido o fr o dependen de factores como tama o de la habitaci n altura del techo cantidad de ventiladores y dem s El interruptor lateral controla la direcci n Hacia adelante hacia la izquierda o rever sa hacia la derecha Clima c lido Hacia adelante Un flujo de aire hacia abajo crea un efecto refres cante como se muestra en la figura 16 Esto te permite fijar tu aire acondicionado en una configuraci n m s alta sin afectar tu comodidad Clima fresco Reversa
28. n anterior podr a no aplicarse a su caso Esta garant a le otorga derechos legales espec ficos pero es posible que tambi n tenga otros derechos que var an de un estado a otro Esta garant a sustituye todas las garant as anteriores Los costos de env o de cualquier devoluci n de productos hecha como parte de una reclamaci n de garant a deben ser pagados por el cliente NOTA IMPORTANTE Para asegurar la garant a de servicio si es necesario registre su ventilador gpwarranty com Para obtener una garant a de servicio debe pre sentar una copia del recibo original de compra G P WARRANTY SERVICE CENTER INC WARRANTY SECTION 1951 N W 22nd STREET FORT LAUDERDALE FLORIDA 33311 Adjunte el recibo aqui para facilitar la localizaci n
29. nment post into the slot on the bottom of the motor and tightening the motor screws Please note that the mo tor screws are pre attached into the blade bracket Figure 14 Figure 14 4 Repeat steps 1 3 for the remaining blades Attaching the Light Kit REMEMBER to disconnect the power 1 Remove the three mounting screws on the light kit fitter Non Light Kit Option Remove the three mounting screws on the black bracket below the motor Disconnecting the two wire connectors for light kit Remove the capacitor amp switches set from switch cap by removing the knurl Blade Balancing All blades are grouped by weight Because nat ural woods vary in density the fan may wobble even though the blades are weight matched The following procedure should correct most fan wobble Check after each step 2 Connect the wires exiting the bottom of the 1 Check that all blade and blade bracket motor with the light kit by connecting the or Speed Switch and tivo screws ol fe screws are secure molded adaptor plugs together verse switch 2 Most fan wobble problems are caused when 3 Slide the light kit fitter into the switch cup Replace the capacitor amp switches set to ex blade levels are unequal Check this level by and secure it using the three screws that tra switch cap using the knurl nut of speed selecting a point on the ceiling above the tip were removed in step 1 switch and two screws of reverse switch re of one
30. no 1 enciende 2 El ventilador hace 1 ruido Soluciones Verifique fusibles o disyuntores principales y secundarios Verifique conexiones de cable de l nea al ventilador y conexiones de cable de interruptor en la carcasa de interruptores PRECAUCI N Aseg rese de que est desactivada la electricidad principal Aseg rese de que todos los tornillos de la carcasa de motor est n ajustados Aseg rese de que los tornillos que unen el soporte de aspa al centro de motor est n bien ajustados Aseg rese de que las conexiones de tuerca de cable no choquen unas con otras o con la pared interior de la carcasa del interruptor PRECAUCI N Aseg rese de que est desconectada la electrici dad Deje un per odo de 24 horas de adaptaci n La mayor a de los ruidos asociados con un nuevo ventilador desaparecen en ese per odo Si usa el kit de luces de ventilador de techo aseg rese de que los tornillos que sujetan el vidrio est n bien colocados Verifique que est tambi n colocada la bombilla de luz Aseg rese de que la cubierta est a corta distancia del techo No debe tocar el techo Aseg rese de que su caja de distribuci n est bien segura y las almoha dillas aislantes de goma se hayan utilizado entre el soporte de montaje y la caja de distribuci n ADVERTENCIA ASEG RESE DE QUE EST DESCONECTADA LA ELECTRICIDAD EN EL PANEL DE ELECTRICIDAD ANTES DE INTENTAR HACER REPARACIONES CONSULTE LA SECCI N C MO H
31. npacking Your Fan Blade attachment hardware 15 Screws rubber washers pre attached to the bracket Mounting Hardware 1 bolt 1 clevis pin 1 rubber gasket Electrical hardware amp Balancing Kit 3 plastic wire connectors 1 pull chain for the fan 1 pull chain for the light kit blade balancing kit e Tools Required Phillips screw driver straight slot screw driver adjustable wrench step ladder and wire cutters Mounting Options If there isn t an existing mounting box then read the following instructions Disconnect the power by removing fuses or turning off circuit breakers Secure the outlet box directly to the building structure Use appropriate fasteners and building materials The outlet box and its support must be able to fully support the moving weight of the fan at least 35 Ibs Do not use plastic outlet boxes WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR PERSONAL INJURY MOUNT FAN ONLY TO AN OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT AND USE THE MOUNTING SCREWS PROVIDED WITH THE OUTLET BOX OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURES MAY NOT BE ACCEPT ABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED CONSULT A QUALIFIED ELEC TRICIAN IF IN DOUBT Figures 1 2 and 3 are examples of different ways to mount the outlet box Figure 1 LA ayi v ae Be t Outlet Box
32. ntes de la instalaci n ADVERTENCIA PARA REDUCIR EL RIESGO DE LESIONES PERSONALES NO DOBLAR LOS BRAZOS DE LAS ASPAS TAMBI N LLAMADOS REBORDES DURANTE O DESPU S DE LA INSTALACI N NO UBICAR OBJETOS EN LA TRAYECTORIA DE LAS ASPAS NO UBICAR OBJETOS EN LA TRAYECTORIA DE LAS ASPAS ADVERTENCIA RETIRA LOS TOPES DE GOMA DEL MOTOR EN LA PARTE INFERIOR DEL VENTILADOR ANTES DE INSTALAR LAS ASPAS O PROBAR EL MOTOR Desempacar tu ventilador y revisar el contenido Deber tener los siguientes art culos Bb un Ensamblado del motor del ventilador Cubierta Aspas 5 Juego de soportes de aspa 5 con tornillos del motor preatornillados Ensamblado de tubo bajante bola 6 Soporte de montaje deslizante y herrajes de montaje dentro de la cubierta 7 Soporte del kit de luces 8 Pantalla 9 Cubierta decorativa del collar n del motor 10 Bombilla CFL 11 Cubierta adicional de tapa del interruptor IMPORTANTE ESTE PRODUCTO Y O SUS COMPONENTES EST N PROTEGIDOS POR UNA O MAS DE LAS SIGUIENTES PATENTES DE EE UU 5 947 436 5 988 580 5 971 573 6 010 306 6 039 541 6 046 416 y OTRAS PATENTES PENDIENTES a C Herrajes de montaje de aspas 15 tornillos arandelas de goma montadas en el soporte Herrajes de montaje 1 perno 1pasador tipo horquilla 1 junta de goma Herrajes el ctricos y Kit de compensaci n de aspa 3 conectores pl sticos de cables 1 cadena del ventilador para halar 1
33. o avoid scratching the finish The plating is sealed with a lacquer to minimize discoloration or tarnishing Warning Make sure the power is off before cleaning your fan You can apply a light coat of furniture pol ish to the wood for additional protection and enhanced beauty Cover small scratches with a light application of shoe polish There is no need to oil your fan The motor has permanently lubricated sealed ball bearings Troubleshooting Problem Fan will not start Fan sounds noisy Solution 1 2 Check main and branch circuit fuses or breakers Check line wire connections to the fan and switch wire connections in the switch housing CAUTION Make sure main power is off Make sure all motor housing screws are snug Make sure the screws that attach the fan blade bracket to the motor hub are tight Make sure wire nut connections are not rattling against each other or the interior wall of the switch housing CAUTION Make sure power is off Allow a 24 hour breaking in period Most noises associated with a new fan disappear during this time If using the Ceiling Fan light kit make sure the screws securing the glassware are tight Check that the light bulb is also secure Make sure the canopy is a short distance from the ceiling It should not touch the ceiling Make sure your outlet box is secure and rubber isolator pads were used between the mounting bracket and outlet box WARNING
34. onnect the fan to your household wiring Use the wire Downrod connecting nuts supplied with your fan Se cure the connectors with electrical tape Make sure there are no loose strands or connections 1 Connect the ground conductor of the 120v supply this may be a bare wire or a wire with green colored insulation to the green WARNING ground lead s of the fan Figure 12 When CHECK TO SEE THAT ALL CONNECTIONS ARE TIGHT INCLUDING GROUND AND THAT NO using standard ceiling mounting there are Er AS two green grounding leads one from the CEPT FOR THE GROUND WIRE ceiling mounting bracket and one from the ball downrod assembly When using Close to Ceiling mounting there is only WARNING one green ground lead from the ceiling ELECTRICAL DIAGRAMS ARE FOR REFERENCE mounting bracket since the ball downrod ONLY OPTIONAL USE OF ANY LIGHT KIT SHALL i BE UL LISTED AND MARKED SUITABLE FOR assembly is not used USE WITH THIS FAN Figure 12 a gt L 2 Install the remaining two mounting screws WARNING Finishing the Fan into the holes in the canopy and tighten PLEASE REMOVE RUBBER MOTOR STOPS ON 3 firmly THE BOTTOM OF THEFAN BEFORE INSTALL Installation 3 You may now proceed to attaching the fan ING BLADES OR TESTING MOTOR STANDARD CEILING MOUNTING aaa E WARNING WHEN USING THE STANDARD BALL DOWN ROD MOUNTING THE TAB IN THE RING AT THE BOTTOM OF THE MOUNTING BRACKET MUST REST IN THE GROOVE OF THE
35. ra 3 Nota Tal vez necesites un tubo bajante m s largo para mantener la altura m nima adecuada de las aspas al instalar el ventilador en un techo incli nado El ngulo m ximo permitido es de 30 Si la cubierta toca el tubo bajante retira la cubierta inferior decorativa y gira la cubierta 180 antes de fijarla al soporte de montaje Caja de distribuci n Figura 4 Para colgar tu ventilador donde haya una l m para pero ninguna viga de techo tal vez neces ites una barra colgante de instalaci n como se muestra en la figura 4 disponible en la tienda minorista local de Hampton Bay Como colgar el ventilador RECUERDA desconectar la electricidad Sigue estos pasos para colgar correcta mente tu ventilador NOTA Este ventilador de techo viene con dos tipos de ensamblados de soporte la in stalaci n de techo est ndar con tubo bajante y bola y casquillo de montaje y el montaje cerca del techo El montaje cerca del techo se recomienda en habitaciones con techos de menos de 8 pies de altura o en reas donde se desee espacio adicional desde el piso hasta las aspas de ventilador Cuando uses una in stalaci n con un tubo bajante est ndar la dis tancia desde el techo a la parte inferior de las aspas ser de 12 pulgadas aproximadamente La instalaci n cerca del techo reduce la dis tancia desde el techo a la parte inferior de las aspas a 8 pulgadas aproximadamente Una vez elegido el tipo d
36. rre 3 tornillos Figura 8 Collar n Tornillo y arandela de cierre Como instalar el ventilador en l a caja el ctrica Caja de distribuci n aprobada por UL Tornillos de montaje provistos junto a la caja de distribuci n Montaje cerca del techo Montaje est ndar ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO DESCARGA EL CTRICA O LESIONES PER SONALES MONTA EL VENTILADOR SOLO SO BRE UNA CAJA ELECTRICA MARCADA COMO Deslizar placa de montaje sobre las cabezas Placa de montaje de los tornillos en el techo APROBADA COMO SOPORTE DE VENTILA DOR Y USA TORNILLOS DE MONTAJE QUE VIENEN CON LA CAJA ELECTRICA Pasa los cables de 120 voltios a trav s del orificio central en el soporte de montaje de techo como lo muestra la figura 10 Cables de 120V Figura 10 4 Con cuidado levante el ensamble hacia el soporte de montaje del techo y cuelgue el Figura 11 2 Instala el soporte de montaje de techo so ventilador del gancho suministrado usando bre la caja el ctrica deslizando el soporte uno de los orificios en el borde exterior de de ay nee a Pepa tornillos ent la cubierta de techo Figura 11 Si usas el ADVERTENCIA istrados con la caja el ctrica Cuando uses montaje est ndar asienta la bola de sopo el montaje cerca del techo es importante LAS RANURAS DE CIERRE DE LA CUBIERTA DE pode montaieeste aliado Si rte en el casquillo del soporte de montaje TE
37. s puede ser un cable desnudo o ADVERTENCIA VERIFICA QUE TODAS LAS CONEXIONES ES un cable con aislante verde al los cable s terminal es a tierra verde s del ventila dor Figura 12 Cuando uses el montaje de techo est ndar existen dos cables termina les a tierra verdes uno desde el soporte de montaje de techo y otro desde el ensamble del tubo bajante y la bola Cuando uses el montaje cerca del techo existe solamente Ze T N BIEN AJUSTADAS INCLUIDA LA CONEX I N A TIERRA Y QUE NO HAYA NING N CABLE PELADO VISIBLE EN LAS TUERCAS PARA CA BLE EXCEPTO EL DE TIERRA ADVERTENCIA LOS DIAGRAMAS ELECTRICOS SON SOLO UNA REFERENCIA EL USO OPCIONAL DE KITS DE LUCES DEBE ESTAR APROBADO POR UL Y ES TARA MARCADO COMO ADECUADO PARA SER USADO EN ESTE VENTILADOR BLANCO BLANCO Figura 12 Fin de la instalaci n del ventilador MONTAJE DE TECHO ESTANDAR ADVERTENCIA CUANDO USES EL MONTAJE DE TUBO BAJANTE Y BOLA ESTANDAR LA PESTANA EN ELARO EN LA PARTE INFERIOR DEL SOPORTE DE MON TAJE DEBE ENCAJAR EN LA RANURA DE LA BOLA DE SOPORTE SI NO ENCAJA CORRECTA MENTE SE PUEDE DA AR EL CABLEADO 1 Alinea las ranuras de cierre de la cubierta de techo con los dos tornillos de la placa de montaje Alza para enganchar las ranuras y gira de izquierda a derecha para asegurar en su sitio Ajusta con firmeza los dos tornillos de montaje 2 Instala los dos tornillos de montaje restant es en los orificios d
38. ting bracket on the Mounting Screws SuppliedWith Outlet Box UL Listed Outlet Box Slide M Bracket Over Screw Heads Ceiling Mounting Bracket 120V Wires Figure 10 Close to Ceiling Mounting Standard Mounting 3 Securely tighten the two mounting screws 4 Carefully lift the assembly up to the ceiling outlet box by sliding the mounting bracket over the two screws provided with the outlet Figure 11 box When using close to ceiling mounting it is important that the mounting bracket be level If necessary use leveling washers not included between the mounting bracket and the outlet box Note that the flat side of the mounting bracket is toward the outlet box Figure 10 CAUTION WHEN MOUNTING THE FAN ON A SLOPED CEILING THE STANDARD BALL DOWNROD MOUNTING METHOD MUST BE USED MAKE SURE THE MOUNTING BRACKET SLOTS ARE ON THE LOWER SIDE BY SLIDING THE MOUNT ING BRACKET FROM THE TOP DOWN mounting bracket and hang the fan on the hook provided by utilizing one of the holes at the outer rim of the ceiling canopy Fig ure 11 If using standard mounting seat the hanger ball in the mounting bracket socket Make sure the tab on the mounting bracket socket is properly seated in the groove in the hanger ball Figure 11 WARNING THE HOOK AS SHOWN IN FIGURE 11 IS ONLY TO BALANCE FAN WHILE ATTACHING WIRING FAILURE TO HANG AS SHOWN IN FIGURE 11 MAY RESULT IN HOOK BREAKING CAUSING THE FAN TO

Download Pdf Manuals

image

Related Search

Related Contents

    Bragg Institute Customer Portal - Proposal Creation User Guide PO    DHAH DECT User Guide  Dosimetry Check - MathResolutions.com  Endosense  Utilisation de emacs  BaByliss G895E Beautyliss + Shaving head, Bikini trimmer, Rechargeable    

Copyright © All rights reserved.
Failed to retrieve file