Home
Dale Tiffany STH11277 Installation Guide
Contents
1. G SPRINGDALE ASSEMBLY INSTRUCTIONS Important Safety Instructions Power at the Fuse Box should be disconected before installing this fixture The Fixture ground wire bare or green installed wire is NOT connected to current carrying supply wires The insulation on any of the wires must not be damaged during installation No rough or sharp edges are in contact with any of the wires Fixture wires are connected to the proper house supply wires We recommend professional installation by a licensed electrician c Do not use light bulb s with wattage greater than those E specified for this fixture Power is off when installing light Listed bulb s into the fixture Insure the outlet box is well mounted to the building structure and will be able to support the weight of the fixture The use of a crossbar is recommended APX WT 14 LBS O Read directions and follow steps 1 12 2 Carefully unpack and layout the parts as shown in illustration and read all instructions before starting 3 Follow numbered steps on diagram Screw Crossbar 3 to Ceiling Outlet Box with Ceiling Screws 4 attach Threaded Rod 5 to Crossbar 3 Screw Nut 6 and Loop 7 to Threaded Rod 5 OF PN GT 4 Raise Canopy 8 and tighten Loop Collar 9 connect fixture vs 7 chain 10 to the loop with desire length of chain 11 12 2 t 5 After connecting chain loosen Loop Collar 9 an
2. la ilustraci n y lea las instrucciones Seguir los pasos en el diagrama atornille la abrazadera 3 a la caja el ctrica con los tornillos 4 colocar el espiga roscada 5 lt gt 3 a la abrazadera de montage 3 Colocar la tuerca 6 y el Levantar la base 8 para apretar el enganche de anillo 9 conectar la cadena de la l mpara 10 al enganche de anillo colocando la cadena al tama o que se desea 11 12 Despues de conectar la cadena suelta al enganche de anillo Colocar las cables de la l mpara 13 atraves de la cadena elenganche de anillo la base el otro enganche de anillo y la espiga roscada Conectar las cables del suministra el ctrico a los cables de la lampara utilizando los conectores de cable 17 I Conecte el cable liso positivo de la l mpara con el cable de suministro negro con conector de empalme pl stico 17 Rosque el conector en direcci n de las manecillas II Conecte el cable estriado negativo de la l mpara con el cable de suministro blanco de la caja de distribuci n 111 Tratar de jalar un poco las conexi nes de los cables para asegurar que estan bien colocadas Si se salen los cables al jalar el conector se devera cuidadosamente volver a conectar IV Envolver por separado las conexi nes de los cables utilizando cinta adhesiva para conductos el ctricos Envolviendo hasta una pulgada de largo los cables incluyendo el conectores V Si la caja el ctrica provee de cable de tierra co
3. d lower 2 gt Canopy 8 over chain 6 Thread Fixture Wires 13 through Chain pass Loop Collar Canopy Loop and Threaded Rod Connect Supply Wire with Fixture Wire using Wire Nut Connectors 17 Please see connection procedures below A I Connect the positive smooth wire of the fixture with A 10 Black supply wire with wire nut connector 17 Screw the o ecient Danger Tum Power Of S connector clockwise until you feel a firmness bi 7 A az 11 Connect the negative ribbed wire from the fixture to the 12 amiens white supply wire from the outlet box in the same manner Y A D decables 111 Try gently to pull the connector off the wires If you can pull Y x the connector off carefully re do the step above and check again 43 for a firm connection IV Separately wrap the wires connections using electrical tape one inch below and include the connector V If your outlet box is provided with a grounding wire green or bare copper only attach this wire and the bare copper wire from the fixture to the green ground screw by wrapping both wires under the head of the screw and tightening screw If outlet box is not provided with grounding wire attach only the bare copper wire from the fixture to the green grounding screw Tuck all wires into Ceiling Outlet Box 7 Secure Canopy by screwing Loop Collar onto Loop 8 Follow Diagram on back side for fixture ass
4. embly instructions A G SPRINGDALE e Chain Loop Collar STH11277 a WARNING TO AVOID RISK OF ELECTRICAL SHOCK BE SURE TO SHUT OFF POWER WHILE INSTALLING OR SERVICING THIS FIXTURE Finial Screw 9 Hook chains onto loop collar of the upper canopy to lower canopy 10 Attach finial and secure with the screws S 11 Place the shade over sockets and y AYN PROS Ly HAN NS tighten socket ring securing shade q q ACIDO in place at 12 Install bulbs into the bulb sockets a FOR RETURN SHIPPING PURPOSES i PLEASE RETAIN OR Uses 3 maximum 60Watt Type A Bulbs IGINAL PACKAGING TO MINIMIZE DAMAGE Or 3 maximum 13Watt CFL Bulbs Bulbs not included COMPONENT LIST Item Design Components Qty A fi a A AN Shade 3 pcs X Socket Ring SPARE PARTS a Revision 03 13 12 LAYOUT ALL COMPONENTS AND REVIEW PARTS BEFORE ASSEMBLY Made in China Hecho en China STH11277 APX WT 14 LBS O Lea las instrucciones y siga los pasos 1 12 antes de comenzar w enganche de anillo 7 a la espiga 5 gt un 9 y bajar la base 8 sobre la cadena a Vea por favor conexi n procedimientos abajo del reloj hasta que sienta firmeza de la misma forma y apretar el conector firme a los cables todos los cables y conectores 2 Desempaquete y presente cuidadosamente las piezas a las indicaciones de
5. lor verde o color cobre conectrar el cable de tierra de la caja el ctricia y el cable de tierra de la l mpara al tornillo verde de la abrazadera de montage juntando 7 Asegure la base atornillando el enganche del anillo al anillo 8 Seguir el diagrama del lado de atras para seguir las instrucciones del ensamblado de la l mpara AAA es G SPRINGDALE INSTRUCCIONES DE ASAMBLEA Instrucciones de seguridad importantes QM Se debe desconectar la alimentaci n en la caja de fusibles antes de instalar esta l mpara El conductor de tierra de la l mpara desnudo o verde instalado NO debe estar conectado a conductores de suministro que lleven corriente Cc Ninguno de los cables debe sufrir da o en el aislamiento durante la instalaci n Listed No debe haber bordos rugosos o filosos en contacto con alguno de los cables Los cables de la l mpara se deben conectar a los cables de suministro correctos de la casa Recomendamos instalaci n profesional por un electricista licenciado Noutilice bombillas de un vataje mayor al especificado de las bombillas para esta l mpara El suministro debe estar cortado durante la instalaci n en la l mpara Aseg rese de que la caja de salida est bien montada en la estructura de la construcci n y de que pueda sostener el peso de la l mpara El uso de una abazadera de montage es recomendado G SPRINGDALE Dose Superior A
6. nillo de Enganche STH11277 poset interior ADVERTENCIAS PARA EVITAR EL RIESGO DE 7 DESCARGA ELECTRICA ASEGURESE DE DESCONECTAR LA ALIMENTACI N DURANTE LA INSTALACI N O SERVICIO DE ESTE APARATO Gancho 9 Conecte las cadenas en el anillo de i rj Tomillo enganche del dosel superior al dosel inferior 4 1 fio 10 Conecte el remate y asegurar con los Eso tornillos 5 AN Pantalla 11 Coloque la pantalla en el z calo y KE iT TN a an Y atornille el anillo de enchufe asegurando m Anillo de Enchufe la pantalla en su lugar a 12 Inserte bombillas en la z calo Usar 3 60 vatios m ximo Tipo A bombillas O 3 m ximo bombillas CFL de 13 vatios Bombillas no incluidas LISTA DE COMPONENTS Tema Dise o Componentes Cantidad A Pantalla 3 piezas B Toor Anillo de Enchufe 3 piezas PIEZAS DE REPUESTO Revision 03 13 12 DESEMPAQUETE TODOS LOS COMPONENTES Y REVISE LAS PIEZAS Made in China Hecho en China ANTES DE LA ASAMBLEA
Download Pdf Manuals
Related Search
Related Contents
Einbauanleitung Installation Manual VW up! 12/2011 MDC Controller Manual - 1.0 (SPA) Verificar os itens incluídos no pacote Peças e controlos WP-FX701 使用説明書 Technische Daten User Manual: Teseq NSG 3040 4kV Conducted Lampe torche à LED 10 W Mode d`emploi Lampe torche à UPSの進化は、ネットワーク対応力に現れる。 INSTALLATION GUIDE Esmalte Alquídico Serie 31 Copyright © All rights reserved.
Failed to retrieve file