Home
Minka Lavery 4365-84 Instructions / Assembly
Contents
1. INSTALLATION INSTRUCTION 4365 For Flush Mount Ceiling Fixture WARNING SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER AVERTISSEMENT COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR READ AND SAVE THESE INSTRUCTIONS MOUNTING THE FIXTURE Fig 1 1 Shut off the power at the circuit breaker and remove the old fixture including the mounting hardware 2 Carefully remove the fixture from the carton and check that all parts are included as shown in the A Ground Screw illustration a ff 3 Mounting screws 2 3 Thread the two mounting screws C Size 8 i O Junction box screws 2 32 1 5 L about 1 4 into the pre drilled holes in the AURE crossbar A 4 Secure the crossbar A to the junction box using the junction box screws B Size 8 32 0 6 L The side of the mounting bar marked GND must face out Set A 016 Crossbar CONNECTING THE WIRES Fig 2 5 Atthis point connect the electrical wires as shown in Fig 2 making sure that all wire connectors are secured If your outlet box has a ground wire green or bare copper connect the fixture s ground wire directly to the mounting plate using the green screw provided After the wires are connected tuck them carefully inside the outlet box COMPLETING THE INSTALLATION Fig 1 6 Raise and mount the ceiling pan D by placing it over both mounting screws C so that they protrude throu
2. gh the keyholes in the bottom of the pan Rotate the ceiling pan D until the screws are in the slots of the keyholes and tighten with a screwdriver Install the light bulb s in accordance with the fixture s specifications DO NOT EXCEED THE SPECIFIED WATTAGE NE PAS DEPASSER LA PUISSANCE Fig 2 NOMINALE MAXIMALE to 7 Thread the nut F onto the nipple H then thread FIXTURE Bae enqurE the nipple G into the coupling E and tighten with Back ai eee Ip Bare 1 Copper Ground the nut F 8 Slide glass H and iron washer J onto the nipple G and secure with the hex nut K 9 Slide the cap L and the cap M over the nipple G and secure with the finial N HOUSE WIRES I 1 i Green or i Neutral Bare Copper Ground Return power to the junction box and test the fixture Your installation is now complete Wi ae american cll Jus lighting ESAE LISTED NOTE CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR MIN 90 C SUPPLY CONDUCTORS
Download Pdf Manuals
Related Search
Related Contents
Manuel d`utilisation - WOPA Klauwverzorging Nederland Muvit MUSLI0535 mobile phone case Agone 5 et 6 Contour® Power Pressure 3 types Mega Station 660/11/270 Mega Station 660/15/270 取扱説明書 - Korg CEREC 3 Franke Active Doccia Copyright © All rights reserved.
Failed to retrieve file