Home
Hampton Bay ES729BAX Use and Care Manual
Contents
1. PENDANT INSTALLATION INSTRUCTIONS Please read carefully and save these instructions as you may need them ata later date SAFETY WARNING BE SURE TO DISCONNECT THE POWER BY TURNING OFF THE CIRCUIT BREAKER OR BY REMOVING THE FUSE AT THE FUSE BOX TURNING THE POWER OFF USING THE LIGHT SWITCH IS NOT SUFFICIENT TO PREVENT ELECTRICAL SHOCK NOTE The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur It must be understood that common sense caution and care are factors which cannot be built into any product These factors must be supplied by the person s installing this unit READ AND SAVE THESE INSTRUCTIONS CAUTION If you feel you do not have electrical wiring experience refer to a do it yourself wiring handbook or have the fixture installed by a qualified licensed electrician GENERAL 1 Be sure to read these installation instructions and review the diagrams thoroughly before installation 2 All electrical connections must be in accordance with local codes and the National Electrical Code If you are unfamiliar with methods of installing electrical wiring secure the services of a qualified licensed electrician 3 Before starting the installation disconnect the power by turning off the circuit breaker or by removing the fuse at the fuse box Turning the power off using the light switch is not sufficient to prevent electrical shock IMPORTANT SA
2. n domiciliaria verde cobre por separado 3 Coloque los dos tornillos 7 en los dos orificios ranurados del soporte de montaje 6 y fije el soporte a la caja de empalme 4 Alinee los dos orificios ranurados del roset n del cielo raso 9 con los dos tornillos abocardados que est n fijados al soporte de montaje Presione y gire el roset n en sentido horario hasta que los tornillos queden alineados con la secci n m s angosta del orificio roscado 5 Use el tornillo abocardado 8 provisto para fijar el roset n al soporte de montaje a trav s del orificio roscado restante y luego fije el roset n apretando los otros dos tornillos del soporte de montaje 6 Fije el artefacto colgante enroscando el conector r pido 11 a la base de conector 10 y apri telo Instalaci n con el adaptador de riel flexible 1 Desenrosque el capuch n del adaptador de riel flexible 13 inserte el adaptador 15 en el riel 14 y luego apriete el adaptador con el capuch n 2 Fije el artefacto colgante enroscando el conector r pido 11 en la base del adaptador de riel 16 Cambio de bombillas Desconecte la alimentaci n el ctrica Desenrosque el conector r pido de la base ubicada en el adaptador de riel Desconecte la energ a el ctrica y deje que se enfr e antes de reemplazar la bombilla Retire la bombilla usada e inserte en el portal mpara una nueva bombilla MR16 C de dos pines y 50 W como m ximo Enrosque el conector r pido en el
3. roset n del cielo raso o en el adaptador de riel flexible Restablezca la corriente el ctrica PRECAUCI N Observe el tipo y el valor m ximo de potencia de la bombilla en la etiqueta que est cerca del portal mpara On AN gt 14 1 Caja de empalme 1 15 2 Conector i 3 Cable negro del artefacto 7 10 4 Cable blanco del artefacto 5 Cable de tierra del artefacto 1 1 6 Soporte de montaje 7 Tornillo de montaje 8 Tornillo de montaje 9 Roset n 10 Base del conector r pido 11 Conector r pido 12 L mpara 1 11 13 Capuch n del adaptador 14 Riel A 15 Adaptador oe 16 Base del adaptador i 12
4. FETY INSTRUCTIONS Do not install this lighting system in a damp or wet location Lighted lamp is hot Caution hot surface Keep away from curtains and other combustible materials Turn off electrical power and allow to cool before relamping Lamp gets hot quickly Do not touch lamp hot lamp lens guard or enclosure at any time Use a soft cloth Oil from skin maydamage lamp Instructions pertaining to risk of fire or injury to persons INSTALLATION amp OPERATION INSTRUCTIONS This pendant is already assembled and suitable for installing with a Ceiling Canopy or Flexible Track to accommodate your selection D APwON gt Installing with Ceiling Canopy 1 Pull the supply wires and the house ground wire out from the outlet box 1 2 Wiring Connections Using the 3 wire connectors 2 to connect the fixture black wire 3 to the house live wire black wire and the fixture white wire 4 to the house neutral wire white wire and the bare copper ground wire 5 to the house ground wire green copper separately 3 Put the two screws 7 into the two key holes of the mounting bracket 6 and fasten the mounting bracket onto the outlet box 4 Align the two slotted mounted holes of the ceiling canopy 9 with the two countersunk screws that are attached to the mounting bracket Push and turn the canopy clockwise until the screws are aligned with the narrowest section of the screw hole 5 Use the countersunk screw 8 provided to fa
5. Lea cuidadosamente y guarde estas instrucciones porque puede necesitarlas mas adelante SEGURIDAD ADVERTENCIA ASEGURESE DE CORTAR LA ALIMENTACION ELECTRICA GENERAL CON EL INTERRUPTOR PRINCIPAL O QUITANDO LOS FUSIBLES DE ENTRADA DESCONECTAR LA ENERGIA EN EL INTERRUPTOR DE LA LUZ NO ES SUFICIENTE PARA EVITAR DESCARGAS ELECTRICAS NOTA Las importantes recomendaciones e instrucciones proporcionadas en este manual no abarcan todas las condiciones y o situaciones posibles que pudieran presentarse Se sobreentiende que el sentido com n la precauci n y la atenci n al trabajo no son parte de un producto Son factores que debe tener en cuenta quien ejecute la instalaci n de esta unidad INSTRUCCIONES DE SEGURIDAD IMPORTANTES No instale este sistema en lugares h medos o mojados La l mpara encendida est CALIENTE PRECAUCI N Superficie caliente Mantener alejada de las cortinas y otros materiales inflamables desconecte la energ a el ctrica y deje que se enfr e antes de reemplazar la l mpara El bulbo l mpara se CALIENTA r pidamente No toque el bulbo en ning n momento No toque el cristal la protecci n o la envuelta calientes Use un pa o blando La grasitud de la piel puede da ar el bulbo 6 Instrucciones relativas al riesgo de incendio o lesiones a personas LEA Y CONSERVE ESTAS INSTRUCCIONES PRECAUCI N Si piensa que no tiene suficiente experiencia en cableados el ctricos consulte un manual de cableado tipo h galo u
6. sted mismo o solicite que un electricista calificado y matriculado instale su artefacto INDICACIONES GENERALES 1 Aseg rese de leer estas instrucciones de instalaci n y revisar los diagramas con cuidado antes de la instalaci n 2 Todas las instalaciones el ctricas deben observar los c digos locales y el C digo de Electricidad Nacional de EE UU Si usted no est familiarizado con los m todos de instalaci n del cableado el ctrico contrate los servicios de un perito electricista habilitado 3 Antes de comenzar la instalaci n desconecte la alimentaci n el ctrica con el interruptor general o retirando el fusible en la caja de fusibles Cortar la alimentaci n al circuito solamente con la llave de luz no es suficiente para prevenir una electrocuci n INSTRUCCIONES DE INSTALACI N Y USO Este artefacto colgante ya est armado y es apto para instalaci n en el cielo raso con un roset n o riel flexible seg n sea su elecci n ABONA taci n con un roset n de cielo raso En la caja de empalme 1 tire hacia afuera los cables de alimentaci n y el conductor de tierra de la instalaci n 2 Conexiones del cableado Use los 3 capuchones de empalme 2 para conectar el cable negro del artefacto 3 al cable del vivo de la instalaci n domiciliaria cable negro el cable blanco del artefacto 4 al cable del neutro de la instalaci n domiciliaria cable blanco y el conductor desnudo de cobre 5 al cable de tierra de la instalaci
7. sten the canopy to the mounting bracket through the remaining screw hole then secure the canopy by tightening the other two screws on the mounting bracket 6 Attach the pendant by screwing the quick connector 11 into the quick connector base 10 and fasten it Installing with Flex Track Adaptor 1 Screw out the flex track adaptor cap 13 then insert the adaptor 15 into the track 14 then tighten the adaptor with the adaptor cap 2 Attach the pendant by screwing the quick connector 11 into the track adaptor base 16 Relamping 1 TURN POWER OFF Screw the quick connector off the connector base or the track adaptor allow to cool before replacing lamp Remove the old bulb and insert new MR16 C 50W maximum bulb into the socket Screw the quick connector into the ceiling canopy or flexible track adaptor 6 Restore the electrical power CAUTION Refer to the relamping label near the lampholder for recommended bulb type and maximum wattage allowed IRN ee 13 1 Outlet Box 14 2 Connector P 3 Fixture Black Wire IJ 15 4 Fixture White Wire 16 5 Fixture Ground Wire 6 Mounting Bracket 1 1 7 Mounting Screw 8 Countersunk Screw 9 Canopy 10 Quick Connector Base 11 Quick Connector 12 Bulb i 11 13 Adaptor Cap 14 Track T 15 Adaptor ma 16 Adaptor Base f 12 ARTEFACTO COLGANTE INSTRUCCIONES DE INSTALACION
Download Pdf Manuals
Related Search
Related Contents
Bedienungsanleitung ipr-SCU-DA-95-120-2014 Handbuch - iCar-Tech Intel BX80637I33240 BX80637I33240 User's Manual User Guide for LabelTrace (non GPASS) atento - Este Es Mi Bus Betriebs- und Montageanleitung CPM «M Lucent Technologies Telephone User Interface Serenade User's Manual Copyright © All rights reserved.