Home
        Zurn-Wilkins 2-975XL2SEU Use and Care Manual
         Contents
1. Double Check Valve Backflow Preventer  Reduced Pressure Principle Backflow Preventer    Model 950  950XL  975  amp  975XL JZURN     Draining Procedure for Freeze Protection WILKINS    TEST COCKS  4     INLET SHUT OFF  OUTLET SHUT OFF VALVE  3   VALVE  5     OUTLET DRAIN wi  VALVE  6     MAIN SHUT OFF    J VALVE  1   COVERS  7  L     lt  lt  DIRECTION OF FLOW    INLET DRAIN  VALVE  2    IF ALLOWED BY LOCAL CODES        To drain backflow preventer for freeze protection  use the following procedure     1  Turn off main shut off valve  1  that supplies water 5  CAUTION  Open outlet shut off valve to the backflow    to the system  preventer  5  and outlet drain valve  6  to the half  open half closed  45    position after  blow out   2  Open both inlet and outlet drain valves in the system process is completed    2  amp  6   Open inlet and outlet shut off valves on the  backflow preventer  3  amp  5  and all of the test cocks 6  Leave all drain valves  2  amp  6   shut off valves  3  amp  5    4   Leave all valves and test cocks in the half and test cocks  4  in the half open half closed posi   open half closed  45    position to allow full drainage tion  45    for the duration of the winter to prevent  of the ball valves and test cocks  freezing   3  If you wish to  blow out  the system downstream of 7  You may loosen the check valve covers  7  to allow  the backflow preventer  make sure the outlet drain complete drainage of the backflow body   valve  6  is open and the backflow 
2. preventer  shut off valve  5  is closed  CAUTION  Be certain that main shut off valve  1   remains tightly closed to prevent refilling of the  4  Connect an air hose to the outlet drain valve  6  and system  Also  the main shut off valve must be resi   inject an adequate volume of air to remove all water lient seated to insure no leakage of water into the  from the downstream portion of the system  system        WARRANTY  ZURN WILKINS Valves are guaranteed against defects of material or workmanship when used for the services  recommended  If in any recommended service  a defect develops due to material or workmanship  and the device is returned   freight prepaid  to ZURN WILKINS within 12 months from date of purchase  it will be repaired or replaced free of charge  ZURN  WILKINS  liability shall be limited to our agreement to repair or replace the valve only           Proposition 65 Warning This product contains chemicals known to the State of California to cause cancer or birth defects  or other reproductive harm           In accordance with U S  Federal Safe Drinking Water Act Lead Free requirements  as of January 4  2014  this product can only be used in water  systems considered non potable  Please contact your local water utility for further requirements           ZURN  ZURN WILKINS  WILKINS 1747 Commerce Way  Paso Robles  CA 93446 Phone 855 663 9876 Fax 805 238 5766          1IS950 amp 975FP  REV 4 13  www zurn com    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Sanyo VM-6615P User's Manual  Bedienungsanleitung deutsch  Manuel d`utilisation  MAC 250 Krypton/Entour    Copyright © All rights reserved. 
   Failed to retrieve file