1. Operating the Water Heater Turning on the Water Heater 1 Make sure the gas type you will use is same as the type on the data plate 2 Turn on the main gas valve plug in the power cord be sure the socket is well grounded and press the ON OFF button on the control panel Set temperature to 120 3 Turn on the faucet and the fan will begin working You will hear the ignition sound after a few seconds The burner will ignite and hot water will come out If the burner is not ignited successfully the ignition sound will last a few seconds If the burner still fails to ignite turn off the faucet and wait for 10 20 seconds and repeat the above procedures For first use and or if the water heater has not been used for a considerable period of time the repeat of the above procedures may be required due to accumulated air inside the gas pipe Safety Precautions If there is any difficulty in understanding or following the Operating Instructions or the Care and Cleaning section it is recommended that a qualified person or serviceman perform the work DO turn off manual gas shut off valve if DO NOT store or use gasoline or other water heater has been subjected to over flammable vapors and liquids such as heating fire flood physical damage or if adhesives or paint thinner in vicinity of this the gas supply fails to shut off or any other appliance If such flammables must be used open doors and windows fo
2. sure the unit is OFF and the electrical power supply has been disconnected NOT scrub the appliance with a brush Use only mild soapy water other cleaners may damage the surface of the water heater DO NOT remove any label including the rating plate while cleaning or servicing DO NOT splash water on the remote controls when cleaning DANGER Shock Hazard Make sure the electrical power to the water heater is off to avoid potential serious injury or damage to components DANGER Combustible materials such as clothing cleaning materials or flammable liquids etc must not be placed against or next to the water heater Vacation and Extended Shut Down If the water heater is to remain idle for an extended period of time the power and water to the appliance should be turned off The water heater and piping should be drained if they might be subjected to freezing temperatures After a long shut down period the water heater s operation and controls should be checked by qualified service personnel Anti Freezing While the Anti Freezers will help to protect from cold temperatures they will in no way guarantee protection from freeze damage DO NOT rely on the Anti Freezers to fully protect the unit from freezing take all precautions to prevent cold damage Freezing anywhere in the plumbing system can result in damage to the NOTICE The water heater such as a rupture in your Heat Exchanger All pipes
3. ELLO TEMP THE FUTURE OF EFFICIENCY ECCOTEMP TANKLESS WATER HEATERS 7 E A Fm ECCOTEMP 45 H RESIDENTIAL OUTDOOR GAS TANKLESS WAIER HEATER USE amp CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE INSTALLER PHONE 866 356 1992 EMAIL SUPPORT ECCOTEMP COM ADDRESS 315 A INDUSTRIAL RD SUMMERVILLE SC 29483 9 gt PRODUCT SUPPORT ECCOTEMP COM HELP DESK SHOP ONLINE ECCOTEMP COM PRODUCT STORE LOCATOR ECCOTEMP COM LOCATOR 3 ELLO TEMP THE FUTURE OF EFFICIENCY WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier CERTIFIED Use amp Care Manual With Installation Instructions for th
4. ed 12 Remote Control 13 14 Electrical Connection 15 Typical Installation 16 Pipe Insulation 8 17 Installation Checklist 18 Operating Instructions Start UTETE o es 2 155218 Water 21 Temperature Memory 21 Care and Cleaning Maintenance 22222 Housekeeping 22723 Extended Shut Down 23 23 24 Troubleshooting Tips Before vou Cal eos 25 Error Code Guide 2 22 26 FOR YOUR RECORDS Write the model and serial numbers here You can find them on a label on the appliance and or packaging Staple sales slip or canceled check here Proof of the original purchase date is needed to obtain service under the warranty READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your water heater properly A little preventive care on your part can save you time and money over the life of your water heater You ll find many answers to common problems in the Troubleshooting Guide If you review the chart of Troubleshooting Tips first you may not need to call for service READ THE SAFETY INFORMATION Your safety and the safety of others are very important There are many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol Recognize th
5. Intake Inside Corner Electric Meter Qs 18 10 feet from any forced air inlet to the building Any fresh or make up air inlet such as for dryer or furnace area B 2 ee ee is considered to be a forced air inlet Eighteen 18 inches from an inside corner formed by two exterior walls Additional Considerations DO install vent terminal under any patio or deck To help prevent moisture from freezing on walls and under eaves do not locate vent terminal on the side of a building with prevailing winter winds If soffit vent is too close block off and install new vent at another location DO locate vent terminal too close to shrubbery as flue gases may damage them Inside window etc starting Corner 6 Caulk Zone withing oa Caulk all cracks seams and joints within six 6 feet of vent terminal EES Gee GREASE Uere Tubus All painted surfaces should be primed to lessen the chance of physical damage Painted surfaces will require maintenance AX WARNING Moisture the flue gas will condense as it leaves the vent terminal In cold weather this condensate can freeze on the exterior wall under the eaves and on surrounding objects Some discoloration to the exterior of the building is to be expected However improper location or installation can result in severe damage to the structure or exterior f
6. The branch gas supply line to the water heater should be clean black steel pipe or other approved gas piping material A ground joint union or ANSI design certified semi rigid or flexible gas appliance connector should be installed in the gas line close to the water heater The National Fuel Gas Code NFGC mandates a manual gas shut off valve See NFGC for complete instructions If flexible connectors are used the maximum length shall not exceed 36 If lever type gas shut offs are used they shall be T Handle type Compound used on the threaded joints of the gas piping must be of the type resistant to the action of LP gas Use compound sparingly on male threads only A sediment trap should be installed at the bottom of the gas line Do not use excessive force over 31 5 ft lbs in tightening the pipe particularly if pipe tape compound is used as the unit may be damaged The inlet gas pressure to the water heater must not exceed 10 5 w c for natural or 14 w c for LP gas For purposes of input adjustment the minimum inlet gas pressure with main burner on is shown on the water heater rating plate If high or low gas pressures are present contact your gas supplier for correction 1 Product Support Eccotemp com help desk Shop Online Eccotemp com products Store Locator Eccotemp com locator ee Relief Valve A new pressure relief valve complying with the Standard for relief V
7. Under this Warranty Eccotemp Systems will only provide replacement parts as described in the Limited Warranty Period The Owner will be responsible for any cost incurred including labor costs for servicing the unit shipping delivery and handling of the replacement part cost for permits or materials necessary for the repair or incidental costs resulting from damage external to the unit resulting from the failure NOTWITHSTANDING ANYTHING IN THIS WARRANTY TO THE CONTRARY EXCEPT FOR ECCOTEMP SYSTEMS AFFIRMATIVE OBLIGATIONS EXPRESSLY SET FORTH IN THIS WARRANTY ECCOTEMP SYSTEMS DISCLAIMS ANY AND ALL WARRANTIES EITHER EXRESS OR IMPLIED REGARDING THE PRODUCT AND ITS FUNCTIONALIT Y PERFORMANCE MERCHANTABILITY FITNESS FOR PARTICULAR PURPOSE OR INTELLECTUAL PROPERTY RIGHTS ECCOTEMP SYSTEMS DISCLAIMS ALL OTHER OBLIGATIONS OR LIABILITIES ON 5 PART AND NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR ECCOTEMP SYSTEMS AN OTHER LIABILITIES IN CONNECTION WITH THE PERFORMANCE OF THE PRODUCT THIS WARRANTY ONLY COVERS REPLACEMENT PARTS AND DOES NOT COVER COST OF LABOR OR SERVICES UNDER ANY CIRCUMSTANCES This warranty only applies to the 50 states of the U S A and Territories of Canada Eccotemp Systems shall not be liable for any claim or demand against Eccotemp Systems by any other part for damages of any kind including but not limited to incidental and consequential damages arising out of the subject matter of this Agreement Some Sta
8. carefully followed The manufacturer s warranty does not cover any damage or defect caused by installation attachment or use of any type of energy saving Pipe Installation Inlet Pipe and Outlet Pipe Installation Use pressure resistant pipe to connect the inlet and outlet water pipes of the water heater and the local water pipe Make sure to place the rubber ring Before connecting the inlet water pipe flush the inside of the pipe Outlet Water Pipe Drain Valve nlet Water Pipe pamm Nut M Nut Hot Water Pipe Cold Water Pipe During Installation of this water heater Do s or other unapproved devices other than those authorized by the manufacturer into onto or in conjunction with the water heater The use of unauthorized energy saving devices may shorten the life of the water heater and may endanger life and property The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized devices Hot and Cold Pipe Insulation Installation For increased energy efficiency use pipe insulation Please install the insulation according to the illustrations above making sure to insulate all the way to the top Do not cover any drain or pressure valve s Check Valve Ex jor Backflow Preventer ces Gas Inlet nlet Pipe t Hot Water Cold Water NOTICE The hot and cold pipes should be insulated as shown help to provide
9. draining the water heater can cause serious damage to the water heater as well as personal injury including scalding Expansion Tank If Needed e To Hot Water Tec Pressure Check Valve Relief Valve I ea Backflow Pr venter t Manual e B App iance Valve ten B Shut off ee ae I Supplied S Line dp To Suitable Drain Below are instructions for draining water out of the water heater 1 Turn off the switch on the remote control 2 Close the gas shut off valve s 3 Close the water shut off valve 4 Turn the on off switch to the OFF position and disconnect breaker at least 10 seconds after step 1 5 Open drain valve 6 Open all hot water faucets Before proceeding to the next step make sure that COLD water is coming out of all hot water faucets 7 To put the water heater back into operation after draining follow the steps below 8 Reinstall the water filter Close the hot water outlet drain valve 9 Open the water shut off valve and close again after making sure that water comes out from hot water faucets This step is to remove air from the water lines 10 Reconnect the breaker and turn the on off switch to the ON position fully open the gas shut off valve and the water shut off valve NOTICE The water heater may not operate unless the above procedure is followed correctly 3 Product Support Eccotemp com help desk
10. in the hot outlet piping of the water heater to make certain the valve operates freely Allow several gallons to flush through the discharge line to an open drain Rapid closing of faucets or solenoid valves in automatic water using appliances can cause a banging noise heard in a water pipe Strategically located risers in the water pipe system or water hammer arresting devices can be used to minimize the problem Inspect the area around the water heater to ensure a safe operating environment Keep appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids Ensure the unit has not been damaged If damage or denting is present contact a service personnel to verify proper operation Check for any abnormal sounds during normal operation of the water heater All piping should be checked for gas and or water leaks Refer to page 12 of this manual for instructions on leak testing The air intake and cold water supply filters should be cleaned monthly Refer to the Housekeeping section for further information DO NOT operate the water heater if you feel something is wrong with the unit DO NOT allow children to operate or otherwise handle the unit NOTICE If the pressure relief valve on the hot water heater discharges periodically this may be due to a problem in the water system Contact the water supplier or your plumbing contractor on how to correct this DO NOT pl
11. must be anti freezing device works for the water heater unit only adequately protected from freezing Units with Anti Freezers have an automatic heating device and will help to avoid freeze damage but the power must be kept on Freezing will occur and not for the with no power In very cold areas and when the temperature is under 32 F or inlet and outlet in event of an ice storm freezing will occur as the heating power limit is water pipes exceeded If these conditions take place please follow the procedures explained below Draining Procedure When the temperature falls below 32 F water in your plumbing system or water heater can turn to ice and then expand causing damage to the water heater This damage is not covered under your manufacturer s warranty If these conditions are anticipated please drain the water heater as follows to help but not guarantee from freezing 1 Shut off the main gas valve and power 2 Shut off the inlet water valve 3 Open all faucets 4 Take off the drain valve and allow water to drain for 3 minutes or until the unit is empty 5 Making sure all water is out replace the drain valve and shut off the faucets 1 Product Support Eccotemp com help desk Shop Online Eccotemp com products Store Locator Eccotemp com locator ERREUR Care and cleaning of the water heater Draining the Water Heater Flue Terminal WARNING Failure to follow these instructions while
12. the following are determined to be a contributing factor by Eccotemp to the failure of the product Abuse misuse alteration neglect or misapplication Improper dangerous destructive maintenance procedures or inadequate maintenance Damages caused by services performed by servicers other than Eccotemp Systems Installation in a corrosive or otherwise destructive environment Damage as a result of freezing within the unit or surrounding piping Scale buildup Incorrect gas or water pressure Acts of force Majeure Damage as a result of use with non portable untreated or poorly treated well water or water with high PH levels or hardness levels in excess of 12 grains per gallon 200 1 10 Incorrect sizing for the application Products with original serial numbers that have been removed or altered and cannot be readily determined 12 Acts of God including but not limited to fire flood or nature disaster 0110 This Product is not to be used as a pool or spa heater In the event of an Eccotemp Systems recognized defect malfunction or failure to conform to this Warranty and based upon Eccotemp approval of warranty claim Eccotemp Systems at its sole and absolute discretion will settle the warrant claim of such defect malfunction or failure to conform to this Warranty In order to make a claim under this Warranty The Owner must notify Eccotemp of the failure of the Product to conform to this Warranty
13. the hot water outlet as shown on the water heater If reversed the water heater will not function ect fD lt Installation of unions or flexible copper connections are recommended on the HOT and COLD water lines so that the water heater may disconnect easily for servicing if necessary Install a Check Valve between the water heater and the water shutoff valve See illustration to the top left In regards to the HOT WATER OUTLET Connections between the water heater and point s of use should be as short and direct as possible Drain Valve DO NOT use lead or non approved plastic pipe NOTICE The flow rate of hot water may vary when more than two faucets appliances fixtures etc are being used simultaneously NOTICE The pipes MUST be completely drainable If the hot water faucets are located at a point higher than the water heater place a drain valve at the lowest point see illustration to the bottom left Gas Supply WARNING Do not attempt to convert this water heater for use with a different type of gas other than the type shown on the rating plate Such conversion could result in hazardous operating conditions Please have a Manual Gas Appliance Shut off Supplied Sediment Trap Cap professional connect the gas pipe A Manual Gas Appliance Shutoff Valve must be installed at the gas connection of the water heater at the time of installation see diagram to the left
14. ON OFF switch must be provided and If local codes require hardwiring see installed for the incoming 120 VAC power instructions for Hardwiring the Electrical Wire the water heater exactly as shown Serene below A wiring diagram is also found inside A WARNING Shock hazard line voltage is of the cover panel present Before servicing the water heater turn A green screw is provided in the junction off the electrical power to the water heater at the main disconnect or circuit breaker Failure to do so could result in severe personal injury or death Connect the live wire to black leg wire and the neutral wire to the white neutral wire box for grounding connection A CAUTION Label all wires prior to disconnection when servicing controls Wiring errors Can cause improper and dangerous Electric Wiring Diagram operation Verify correct operation after servicing Ground wire eo Power cord Panel Display or Anti freezer for certain models a 4 0000000 ee eee ix ET Ignition L Device T Tm gez 1 00 aU any 1 me A Proportion valve E8 B Proportion valve Heat exchanger protection device Water valve Temp sensor Temp sensor of water inlet of water outlet Water flow sensor 4 Product Support Eccotemp com help desk EE Shop Online Eccotemp com products Store Locator Eccotemp com locator ERREUR Installing the wate
15. P SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Limited Warranty Period This Warranty is extended by Eccotemp Systems to the Owner This warranty takes effect on the date of installation of the Product or 30 days after the date of purchase whichever occurs first and is effective until the specified anniversary of such date as follows 1 Limited Five Year replacement years 1 through 5 of defective parts other than the heat exchanger Labor not included 2 Limited additional Ten Year replacement years 1 through 10 on the heat exchanger when the Product is used in a single family dwelling Labor not included 3 Limited additional Two Year replacement years 1 through 2 on the heat exchanger when the Product is used for commercial capacity if it is used in other than a single family dwelling or if the Product is supplied with pre heated or circulated water labor not included 1 Total Ten Year Years 1 through 10 or 6 500 operational burn hours recorded by the water heater whichever occurs first Item Period of Coverage Heat Exchanger 10 years All other parts 5 years Coverage s are void if the unit is used in a hot water circulation loop in series with a circulation system or where an on demand recirculation system is not incorporated Owner is responsible for all other costs incidental to repair such as labor shipping delivery and permits Proof of purchase required Products repaired will be covered und
16. Shop Online Eccotemp com products o Store Locator Eccotemp com locator Before You Call For Service Troubleshooting Tips Save time and money Review the charts on the following pages first and you may not need to call for service This water heater incorporates a variety of shut off devices that prevents the operation of the water heater down if undesirable combustion conditions occur Such as the presence of a blockage of the combustion air vent insufficient gas or pressure which can impact the safe operation of the water heater Please contact a Qualified Service Technician if this occurs Possible Cause What To Do aa Check shutoff valve and open fully Not enoughor fully opened no hot water Hot water faucet is not Open hot water faucet completely The main burner goes off when incomin fully opened 5 5 water volume is inadequate Water piping is frozen Allow piping to thaw No electricity or water Check that proper power is being supplied supply is cut off and or water supply is adequate Unit is not ON Turn the unit ON by the button on the remote control ie ey Increase the temperature setting be set too low lonis Check replace if necessary if applicable Error code displayed See instructions for Error Code and if remote control panel required contact a dealer for service Increase the temperature setting Water not set too
17. additional freeze protection DO check inlet gas pressure to ensure that it is within the range specified on the rating plate DO provide adequate air for combustion and ventilation as discussed in the Use amp Care Manual and the National Gas Code CAN CGA B 149 in Canada DO maintain proper clearances to combustibles as specified by applicable code DO ensure that the flue terminal location complies with the guidelines found in the Use amp Care Manual and National Fuel Gas Code CAN CGA B 149 in Canada Dont s DON T block or restrict Air Intake Opening located on the back side of the water heater DON T remove the front cover unless absolutely necessary This should only be done after being examined by a qualified service technician DON T install this product where standing water may occur 1 Product Support Eccotemp com help desk Ba Shop Online Eccotemp com products Store Locator Eccotemp com locator eo Installing the water heater Installation Check List A Water Heater Location Installed OUTDOORS Close to area of mostly used outlet Protected from freezing temperatures Proper clearance from combustible surfaces observed fresh air supply for proper operation of water heater Air supply free of corrosive elements and flammable vapors Provisions made to protect area from water damage Sufficient room to service heater Combustible mater
18. alves and Automatic Gas Shut Off Devices for Hot Water Supply Systems ANSI Z21 22 must be installed at the hot water outlet connection of the water heater at the time of installation Local codes shall govern the installation of relief valves For safe operation of the water heater be sure that The pressure rating of the relief valve must not exceed 150 psi the maximum working pressure of the water heater as marked on the rating plate The BTUH rating of the relief valve must equal or exceed the BTUH input of the water heater as marked on its rating plate No valve of any type should be installed between the relief valve and the water heater Hot Water Valve mE Supply Discharge from the relief valve should be piped to a suitable drain to eliminate potential water damage Piping used should of type approved for the distribution of Line to suitable drain hot water Hot and cold water lines should be insulated up to the water heater NOTICE The above illustrates a pressure only relief valve The discharge line must be NO SMALLER than the outlet If local codes require a of the valve and must pitch downward to allow complete combination temperature drainage by gravity of the relief valve and discharge line and pressure relief valve be installed an extension piece The end of the discharge line should not be threaded or may be needed concealed and should be protected from freezing No val
19. cald injury Contact a licensed plumber or the local plumbing authority for further information NOTICE The factory recommended operating temperatures are between 90 F and 140 F 4 Product Support Eccotemp com help desk Shop Online Eccotemp com products Q Store Locator Eccotemp com locator ERROREM DANGER NATURAL GAS AND LIQUEFIED PETROLEUM MODELS Both LP and natural gas have an odorant added to aid in detecting a gas leak Some people may not physically be able to smell or recognize this odorant If you are unsure or unfamiliar with the smell of LP or natural gas ask the gas supplier Other conditions such as odorant fade which causes the odorant to diminish in intensity can also hide or camouflage a gas leak Always check with commercial leak detector or soapy water Gas detectors are recommended in LP and natural gas applications and their installation should be in accordance with the detector manufacturer s recommendations and or local laws rules regulations or customs Water heaters utilizing LP gas are different from natural gas models natural gas water heater will not function safely on LP gas and vice versa No attempt should ever be made to convert the water heater from natural gas to LP gas To avoid possible equipment damage personal injury or fire do not connect the water heater to a fuel type not in accordance with the unit data plate propane for propane units and natu
20. duct Support Eccotemp com help desk Shop Online Eccotemp com products Store Locator Eccotemp com locator ERREUR Leak Testing WARNING Never use an open flame to test for gas leaks as property damage personal injury or death could result The water heater and its gas connections must be leak tested at normal operating pressures before it is placed in operation Turn on the gas shut off valve s to the water heater Use a commercial leak detector or soapy water solution to test for leaks at all connections and fittings Bubbles indicate a gas leak that must be corrected The factory connections should also be leak tested after the water heater is placed in operation High Altitude Ratings of gas appliances are based on sea level operation and need not be changed for installations at elevations up to 2 000 feet Unit not recommended for elevations in excess of 2 000 feet Installing the water heater Flue Terminal Location The location of the vent terminal depends on the following minimum clearances and considerations see illustration Twelve 12 inches above grade level and above normal snow levels Four 4 feet below or four 4 feet horizontally from any door window soffit under eave vent or gravity air inlet to the building or other appliances or from gas or electric meters Do not locate vent above walkways doors windows air inlets gas or electric Fresh Air meters or other equipment
21. e power socket connecting the water heater should be properly grounded ville 5 29483 E The water heater must be located so it is not subject to physical damage for example by moving vehicles area flooding etc The water heater must be installed vertically with the water gas and power connections on the underside pointing toward the ground Failure to properly install the water heater outdoors as outlined in this manual can result in unsafe operation Hot and cold water lines should be insulated to conserve water and energy DO NOT install water heater where subject to vibrations DO NOT install the water heater in Recreational Vehicles Mobile Homes Boats and other Watercraft DO NOT install the water heater near vents for heating or cooling A minimum of 4 feet should be maintained If the clearances stated on the Instruction Warning Label located on the front panel of the heater differ install the water heater according to the clearances stated on the label WARNING Combustible construction refers to adjacent walls and ceilings and should not be confused with combustible or flammable products and materials Combustible and or flammable products and materials should never be stored in the vicinity of this or any gas appliance 4 Product Support Eccotemp com help desk EE Shop Online Eccotemp com products Store Locator Eccotemp com locator ERROREM ERREUR Ins
22. e Installer Residential Outdoor Gas 140 00 BTU Max Input 6 8 Tankless Water Heater WARNING This water heater may not be suitable for use in manufactured mobile homes Please check local code restrictions pertaining to permanent fixed installations in manufactured homes in your area The purpose of this manual is twofold one to provide the installer with the basic directions and recommendations for the proper installation and adjustment of the water heater and two to the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater This manual also includes a parts list It is imperative that all persons who are expected to install operate or adjust this water heater read the instructions carefully so they may understand how to perform these operations If you don t understand these instructions or any terms within it seek professional advice Any questions regarding the operation maintenance service or warranty of this water heater should be directed to the seller from whom it was purchased If additional information is required refer to the section on If You Need Service Do not destroy this manual Please read carefully and keep in a safe place for future reference Recognize this symbol as an indication of Important Safety Information California Proposition 65 Warning This product contains chemicals known to the State of Californ
23. e measurement should corrosive chemicals sand dirt or be calculated by the distance between the other contaminates water inlet of the water heater ground With inlet water temperatures level to the hot water faucet upper floor level above 32 F but not exceeding 120 F Free of lime and scale deposits DO NOT reverse hot and cold water connections The water heater will not operate Well water systems should be set at a range of 50 60 psi 41 Product Support Eccotemp com help desk EE Shop Online Eccotemp com products o Store Locator Eccotemp com locator ville 5 29483 9 Water Supply Connections Continued Water Filter If a water heater is installed in a closed water supply system such as one having a backflow preventer in the cold water supply line means shall be provided to control thermal expansion Contact the water supplier or local plumbing inspector on how to control this situation Install a shutoff valve near the inlet of the water heater for service and draining purposes Water Filter a Water Inlet Before connecting the water supply pipe to the water heater open the shutoff valve clean out sand debris air caulking material eck Valve or Backflow Preventer etc inside the pipe Connect to the water inlet then check water flow Close the shutoff valve and clean the water filter Be sure to connect the water inlet and
24. er this Limited Warranty for the remainder of term of the original purchase Shipping Related Costs Within the first 30 days of purchase Eccotemp will cover all ground shipping costs for warranty related issues excluding AK Canada and any location outside of the continental US After the first 30 days of purchase Eccotemp will cover all ground non expedited shipping costs to the customer for warranty related issues excluding Canada and any location outside of the continental US After the first 30 days of purchase the customer is responsible for all shipping to Eccotemp regardless of reason or circumstance The method for warranty related shipping will be Ground equivalent with the provider of Eccotemp s choosing AK HI Canada and any location outside of the continental US will be responsible for all shipping costs regardless of reason or circumstance All shipments of any type of product coming to Eccotemp for any reason must have an RGA for any repairs to be made Please contact Eccotemp to obtain an RGA number prior to shipping anything to Eccotemp Failure to do so could result in loss of product Eccotemp will not be responsible for replacement due to loss or damage if these steps are not properly followed Exclusions Please refer to the Installation Manual and Use amp Care Manual supplied with your new Eccotemp Systems product This Limited Warranty becomes null and void if any of
25. h on the remote control and call the call the customer service assistance customer assistance number number in the If You Need Service Code Error Description Possible Cause What To Do Junction port loose The gas valve is not opened or fully opened Water shut off valve is not open Junction port loose dida NO Electric circuit problem Call for Service water coming in Over heating protection By Call for Service over heating controller problem with sensor problem with sensor s plug or socket none of the above Check and open gas fully Check and open water valve Call for Service replace the sensor fix it Cold water temperature replace the computer board Gas pressure is too high Water shutoff valve is not fully opened The temperature is set too low Check shut off valve and open fully Increase temperature setting open circuit of the valve short connect the valve replace the circuit of the valve none of valve replace the computer the above board vent pipe block vent pipe is blocked clean the pipe CAUTION For your safety DO NOT attempt repair of gas piping remote control burners Vent connectors or other safety devices Refer repairs to qualified service personnel CAUTION Make certain power to water heater is OFF before removing protective cover FOR ANY REASON CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can ca
26. holes of control with the holes in the wall and fasten them with wood thread screws See illustration below 2 4 2 00 24 Base of control Wood thread screw 3 Replace the front cover on the remote control 3 Replace the front cover on the remote control 1 Product Support Eccotemp com help desk ms Shop Online Eccotemp com products Store Locator Eccotemp com locator ERROREM AX WARNING Field wiring connections and electri cal grounding must comply with local codes or in the absence of local codes with the la test edition of the National Electrical Code ANSI NFPA 70 or in Canada Canadi an Electrical Code CSA C22 1Part1 Electrical Connection HARDWIRING THE ELE CTRICAL CONNECTIONS POWER CORD Wiring should be carried out by a qualified The electric power supply requirement for electrician in accordance with local codes this water heater is 120 VAC 60HZ 2 Amps The water heater requires 120 VAC 60Hz The water heater comes with a three 3 pin and should be properly grounded power supply cord Use only a power outlet with a ground terminal DO NOT connect grounding wire to water pipes gas pipes telephone cables The installation of an electric leakage lightning conductor circuits and to breaker is recommended GFCI grounding circuit of other equipment that Keep any excess of the power supply cord carry a ground fault interrupter on the outside of the water heater An
27. ia to cause cancer birth defects or other reproductive harm WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Improper installation adjustment alteration DO NOT try to light any appliance service or maintenance can cause property DO NOT touch any electrical switch damage personal injury or death Refer to this manual Installation and service must be performed by a qualified installer service Immediately call your gas supplier from agency or the gas supplier a neighbor s phone Follow the gas supplier s instructions do not use any phone in your building DO NOT store or use gasoline or other flammable vapors or liquids or other combustible materials in the vicinity of this or any other appliance To do so may result in an explosion or fire DO return to your home until authorized by the gas supplier or fire department f you cannot reach your gas supplier call the fire department 4 Product Support Eccotemp com help desk EE Shop Online Eccotemp com products Store Locator Eccotemp com locator Safety Information Safety Precautions 3 6 LP Gas Moses cr 5 Installation Instructions Location 125 Water Connections ER Gas SUP dE 10 Relief 11 Beak Testing 12 bien Atbibtde 12
28. ials such as clothing cleaning materials rags etc clear of the heater and vent piping Water heater is properly attached to the wall B Water Supply Water supply has sufficient pressure Air purged from water heater and piping Water connections tight and free of leaks Water filter is clean and in place Materials used as instructed in this manual Water pipes are insulated C Gas Supply Gas type matches rating plate supply pressure is sufficient for the water heater Gas line equipped with shut off valve union and sediment trap Approved pipe joint compound used Commercial leak detector or soap and water solution used to check all connections and fittings for possible gas leak Gas Company inspected installation if required D Relief Valve Pressure Relief Valve properly installed and discharge line run to open drain Discharge line protected from freezing E Electrical Wiring Voltage matches rating plate Water heater is properly grounded Wiring meets all local codes GFCI Protection where required 1 Product Support Eccotemp com help desk ms Shop Online Eccotemp com products Store Locator Eccotemp com locator Lighting the Water Heater Before operating this water heater be sure to read and follow the instructions on the label pictured below and all other labels on the water heater as well as the warning
29. inish of the building Code requirements are subject to change and may vary by location 3 Product Support Eccotemp com help desk Shop Online Eccotemp com products Store Locator Eccotemp com locator ville SC 29483 AX WARNING Field wiring connections and electrical grounding must comply with local codes or in the absence of local codes with the latest edition of the National Electrical Code ANSI NFPA 70 or in Canada Canadian Electrical Code CSA C22 1 Part 1 Remote Control Installation The following are considerations for determining the location of the remote control s DO NOT install any remote control outdoors Avoid areas where the remote control s Place remote control s out of children s reach subjected to oil and or steam from The remote control s be installed in convenient locations such as the kitchen Laundry room or utility room Avoid areas where chemical agents such as thinner benzine and alkaline are used The included remote control can be placed in convenient location in bathroom however The MAXIMUM distance between the water AVOID areas where water may come into heater and the remote control s installation contact with the control s location is limited to feet Avoid areas where the remote control s No other manufacturer s controls are may be exposed to heat e g stove ranges or suitable for use with this wate
30. is appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS STOP Read the safety information above on this label Turn off all electric power to the appliance GAS SHUT OFF YAINN Set the thermostat to lowest setting VALNE 0 DONOT attempt to light the burner by hand OPEN CLOSE Turn the Gas Shut off Valve located on the outside of the unit clockwise to the OFF position Turn off all electrical power to the appliance 7 Wait five 5 minutes to clear out any gas If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step Turn the Gas Shutoff Valve located on outside of the unit counterclockwise to the ON position Turn on electric power to the appliance Set thermostat to desired setting If the appliance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier TO TURN OFF GAS TO APPLIANCE Turn off all electric power to the appliance if service is to be performed Turn the Gas Shut off Valve located on the outside of the unit clockwise to the OFF position 4 Product Support Eccotemp com help desk Shop Online Eccotemp com products Store Locator Eccotemp com locator OAC ium A e
31. is symbol as an indication of Important Safety Information This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER WARNING CAUTION or NOTICE These words mean DANGER An imminently hazardous situation that will result in death or serious injury A WARNING A potentially hazardous situation that could result in death or serious injury and or damage to property CAUTION potentially hazardous situation that may result in minor or moderate injury NOTICE Attention is called to observe a specified procedure or maintain a specific condition 4 Product Support Eccotemp com help desk Shop Online Eccotemp com products Q Store Locator Eccotemp com locator 5 29483 IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING Be sure to read and understand the entire Use and Care Manual before attempting to install or operate this water heater It may save you time and money Pay particular attention to the Safety Instructions Failure to follow these warnings could result in serious bodily injury or death Should you have problems understanding the instructions in this manual or have any questions STOP and get help from a qualified service technician or the local gas utility DANGER PROPERLY INSTALL WATER HEATER Failure to properly install
32. liance Pressure 4 hated gt Remote Control Shut Off Relief Valve a D np Use amp Care Exposive Screw x 2 pcs Wood Screw 4pcs Washer x 2pcs Manual 3 Product Support Eccotemp com help desk Shop Online Eccotemp com products Store Locator Eccotemp com locator vile sc294833 E Mounting the Water Heater 5 6 Make sure the location of the appliance allows for easy access and operation In case of dry wall or concrete wall use dry wall anchors or lag bolts The water heater requires 120 VAC 60Hz Have a receptacle with ground terminal near the water heater The length of the power supply cord is 5 feet Installation Drill the holes as per the sizes in the figure to the left put 2 Holes expansion screws into the top holes and 2 rubber screws into the bottom holes 4 0 4 deep Hang up the water heater unit tighten the expansion screws and put 2 wood thread screws into the bottom holes CAUTION Reinforcement of the wall is required in case the wall is not strong enough to hold the appliance Water Supply Connections When the water is supplied from a water supply tank the height of the tank and the Plumbing should be carried out by a qualified diameter of the pipes and their relation to plumber in accordance with local codes water pressure should be taken into consideration Gravity water pressure is Use approved plumbing materials and tools
33. low not enough one Check and open the gas valve fully The temperature is set Water too hot 00 high Water shutoff valve is not fully opened Small amount of water Allow more water to flow has been heated Water filter is clogged Clean the filter with a tooth brush Decrease the temperature setting Check shutoff valve and open fully Fan continues to rotate after hot water faucet is closed This function is to purge unburned gas 10 15 seconds Normal operation There is no need to call for service Check for error code 3 Product Support Eccotemp com help desk Shop Online Eccotemp com products Q Store Locator Eccotemp com locator ville SC 29483 2 EU IH Error Code Guide When an error code is displayed If the error code remains shown Close the hot water faucet turn off the Close the hot water faucet and turn off the switch on the remote control switch on the remote control Wait for about 5 minutes before turning the Take the proper action shown below and switch on again attempt operation of the appliance again Open the hot water faucet f the error code is still shown tU Turn off the hot water faucet and turn off NOTICE If an error code other than those liste below is displayed immediately turn off the hot EIS a water faucet take note of the error code turn Take note of the error code displayed and off the switc
34. mp com help desk EE Shop Online Eccotemp com products Store Locator Eccotemp com locator ERREUR IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damage personal injury or loss of life FOR INSTALLATIONS N THE STATE OF CALIFORNIA California Law requires that residential water heaters must be braced anchored or strapped to resist falling or horizontal displacement due to earthquake motions For residential water heaters up to 52 gallon capacity a brochure with generic earthquake bracing instructions can be obtained from Office of the State Architect 400 P Street Sacramento CA 95814 or you may call 916 445 8100 or ask a water heater dealer However applicable local codes shall govern installation For residential water heaters of a capacity greater than 52 gallons or tankless style consult the local building jurisdiction code for acceptable bracing procedures T SAFETY PRECAUTIONS Have the installer show you the location of the gas shut off valve and how to shut it off if necessary Turn off the manual shut off valve if the water heater has been subjected to overheating fire flood physical damage or if the gas supply fails to shut off Read this manual entirely before installing or operating the water heater Use this appliance only f
35. mpany Please don t attempt installation by yourself Improper installation may cause failure or dangerous conditions such as gas leaking or explosion This water heater is an outdoor model and must be mounted on a vertical wall It must not be installed indoors or in a confined space The water heater should be installed close to the most frequently used outlet and its position chosen with safety and service in mind Make sure people particularly children disabled and elderly will not touch the hot water outlet or the flue terminal The flue terminal and air inlet must be clear of obstruction and shrubbery If installed in a public corridor please assure that the surrounding area is free of debris obstruction and flammable materials The unit must be installed on a fire retardant area and must be away from all flammable materials Clearance should be 1 75 ft to the left and right side of flammable materials and 6 75 ft to the front The unit should be installed in open area where strong currents are not prevalent This unit is of high power and will consume a lot of oxygen when working so the installation area must be well ventilated and air in and out of the area has no blockage The outdoor unit should not be installed in a corridor with rooms on the both sides or in the closed corridor Take measures to avoid direct wind rain and snow The installation area should be constructed of fire retardant materials Th
36. nds 150 F About 1 1 2 seconds 55 F About 1 second Table courtesy of Shriners Burn Institute HOT The chart shown above may be used as a guide Ny in determining the proper water temperature for your home pancer Households with small children disabled or elderly persons may require a 120 F or lower temperature setting to prevent contact with HOT water Maximum water temperature occurs while Water temperature over 125 F can cause severe burns burner is on To find water temperature being instantly or death from scalds Children disabled and elderly delivered turn on a hot water faucet and place a are at highest risk of being scalded See instruction manual before setting temperature at water heater Feel water thermometer in the water stream and read the before bathing or showering Temperature limiting valves are thermometer The temperature of the water at the outlet of the water heater can be regulated by setting the temperature on Remote Control The remote control was set at 110 F before it was shipped from the factory The illustration to the bottom left illustrates the Remote Control and how to adjust the water temperature O NOTICE When this water heater is supplying O O gm general purpose hot water requirements for use by individuals a thermostatically controlled mixing valve for reducing point of use water temperature is recommended to reduce the risk of s
37. on the MAIN control cannot be changed The BATH control s will always have PRIORITY over the MAIN control 2e Product Support Eccotemp com help desk EE Shop Online Eccotemp com products Store Locator Eccotemp com locator vile 5 29483 B O 9 Care and cleaning of the water heater Routine Preventative Maintenance DANGER Before manually operating the relief valve make certain no one will be exposed to the danger of the hot water released by the valve The water may be hot enough to create a scald hazard The water should be released into a suitable drain to prevent injury or property damage Ad DANGER Hotter water increases the potential for Hot Water Scalds Ad DANGER Failure to perform the recommended Routine Preventative Maintenance can harm the proper operation of this water heater which can cause carbon monoxide dangers excessive hot water temperatures and other potentially hazardous conditions Properly maintained your water heater will provide years of dependable trouble free service It is recommended that a periodic inspection of the burner relief valve water filter and venting system should be made by service personnel qualified in gas appliance repair It is suggested that a routine preventive maintenance program be established and followed by the user At least once a year lift and release the lever handle on the pressure relief valve located
38. only To conserve energy and to prevent freezing insulate both cold and hot water supply lines NOTICE If the water flow resistance of a DO NOT cover the drain valves shower head is too high the burner in the water heater will fail to ignite Keep the To ensure proper operation of the water shower head clean from debris that could heater the following water pressure cause additional pressure drop guidelines should be followed NOTICE If using mixing valves on the outlet Operation of the water heater requires the choose one which prevents cold water minimum water pressure of 14 psi and a pressure from overcoming hot water line minimum water flow rate of 0 75 gpm pressure Additional water pressure is required for IMPORTANT Do not apply heat to the HOT long pipe runs and outlet fitting s water or COLD water connections Any heat applied pressure drops to the water supply fittings will permanently T damage the internal components of the water o maintain proper performance ensure sufficient water supply pressure The Required Water Pressure Min Operating Water Pressure 14 psi Pipe Pressure Loss Faucet and Shower Pressure Loss CAUTION This water heater must Safety Margin more than 5 psi only be used with the following water To supply hot water to upper floors system conditions additional water pressure 0 44 psi ft With clean potable water free of must be ensured Th
39. or its intended purpose as described in this Use and Care Manual Be sure your appliance is properly installed in accordance with local codes and the provided installation instructions Part of your water heater unless it is specifically recommended in this manual All other servicing should be referred to a qualified technician READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY SAVE THESE INSTRUCTIONS This water heater must be installed in accordance with these instructions local codes utility company requirements and or in the absence of local codes use the latest edition of the American National Standard National Fuel Gas Code A copy can be purchased from either the American Gas Association 400 North Capitol Street Northwest Washington DC 20001 as ANSI standard Z223 1 or National Fire Protection Association 1 Batterymarch Park Quincy MA 02268 as NFPA 54 In Canada the latest edition of the B149 1 Natural Gas and Propane Installation and the Canadian Electrical Code C22 TPartl in the absence of local codes 1 Product Support Eccotemp com help desk ms Shop Online Eccotemp com products Store Locator Eccotemp com locator Installing the water heater Location This water heater is for OUTDOOR installation ONLY Make sure before installation that the gas type you will use is the same type on the data plate The water heater unit should be installed by professionals from your local gas co
40. r ventilation and all gas burning appliances in the vicinity should be shut off including their pilot lights to avoid vapors lighting DO NOT turn on water heater unless water and gas supplies are fully opened DO NOT turn on water heater if cold water supply shut off valve is closed NOTICE Flammable vapors can be drawn by air currents from surrounding areas to the water heater DO NOT allow combustible materials such as newspaper rags or mops to accumulate near water heater 2 Product Support Eccotemp com help desk ms Shop Online Eccotemp com products Store Locator Eccotemp com locator ERROREM Water Temperature Setting DANGER There is hot water scald potential if the temperature is set too high Households with small children disabled or elderly persons may require 120 F or lower temperature setting to prevent contact with HOT water Water Temperature Time To Produce a Serious Burn 120 F More than 5 minutes 125 1 1 2to 2 minutes 130 F About 30 seconds T35 F About 10 seconds 140 F Less than 5 seconds 145 F Less than 3 seconds 150 F About 1 1 2 seconds 155 About 1 second Table courtesy of Shriners Burn Institute Set Temperature Memory Output temperature of water is regulated by setting the temperature on the front of the remote control Safety factors should be considered when selecting the water temperature setting of the water heater s remote cont
41. r heater DO NOT attempt to disassemble the remote control Remote control Connection Installation and Set For Panel Control Remote Control and Remote Control units Panel Control Remote Control and Remote Control units will work with either one or two remote controls If two remotes are desired a wire connector will need to be provided To connect the remote control 1 For one control Plug the aviation joint into the socket directly on the water heater see illustration below Socket on the water heater Remote control Aviation joint 2 For two controls First cut off the aviation joints on the two controllers plug one into the socket on the water heater length is dependent on your requirements and throw away the other Then connect the wires of the aviation joint to the inlet wire of the connector and connect the two remote control to the outlet wires of connector 4 Product Support Eccotemp com help desk EE Shop Online Eccotemp com products Store Locator Eccotemp com locator Installation of Remote Control 1 Remove the front cover of the Remote Control See illustration below z d 0 a e 5 7 Remote control Front cover o Control base 2 Atinstallation site mark and screw two holes with 0 24 with 1 2 depth Insert 2 rubber screws into the holes Place the remote control against the wall align the
42. r heater Typical Installation Some Items May Not Apply Temperature Control Smoke Outlet Smoke Collector Anti Freezer Thermostat Anti Freezer Flame Sensor Pin Heat Exchanger Protection Device Ignition Pin A Heat Exchanger Ignition Pin B Back Cover Burner Assembly Igniter Fan Cold Water Temperature Sensor Auto Water Flow Adjustment Device Gas Valve Assembl Computer Board Hi Bee rp Gas Inlet 4C CDDDDBA w AP Water Outlet 4 ae Water Inlet Smoke outlet Connect port of remote control Water inlet Gas inlet Front cover NOTICE The National Fuel Gas Code NFGC mandates a manual gas shut off valve See NFGC for complete instructions Local codes or plumbing authority requirements may vary from the instructions or diagrams provided and take precedent over these instructions 1 Product Support Eccotemp com help desk Shop Online Eccotemp com products Q Store Locator Eccotemp com locator Insulation blankets available to the general public for external use on gas water heaters are not necessary The purpose of an A insulation blanket is to reduce the WARNING If standby heat loss encountered with ee ee storage tank heaters This water external application of insulation blanket kits heater does not store water making the manufacturer s an insulation blanket unnecessary instructions included with the kit must be
43. r rooms to the main burner flame by air currents Vapors Keep flammable products 1 Far away from heater 2 In approved containers 3 Tightly closed 4 Out of children s reach Installation Do not Install water heater where flammable products will be stored or used unless the main burner flame Is at least 18 above the floor This will reduce but not eliminate the risk of vapors being ignited by the main burner flame Read and follow water heater warnings and Instructions If owners manual is missing contact the retailer or manufacturer Lig Product Support Eccotemp com help desk m Shop Online Eccotemp com products Store Locator Eccotemp com locator sc2s4e3 OG IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING DANGER WATER TEMPERATURE SETTING Safety and energy conservation are factors to be considered when selecting the water temperature setting Water temperatures above 125 F can cause severe burns or death from scalding The thermostat is adjusted to its lowest temperature position when shipped from the factory Be sure to read and follow the warnings outlined on the label pictured below Time Temperature Relationship in Scalds N DANGER ater Temperature Time To Produce a Serious Burn 120 F More than 5 minutes 125 1 1 2to 2 minutes BUF About 30 seconds D5 About 10 seconds 140 F Less than 5 seconds 145 F Less than 3 seco
44. ral gas for natural gas units These units are not certified for any other fuel type LP appliances should not be installed below grade for example in a basement if such installation is prohibited by federal state and or local laws rules regulations or customs Propane or LP gas must be used with great caution It is heavier than air and will collect first in Lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to look and smell for gas leaks Use a soapy solution to check all gas fittings and connections Bubbling at a connection indicates a leak that must be corrected When smelling to detect a gas leak be sure to sniff near the floor also recommended that more than one method such as soapy solution gas detectors etc be used to detect leaks in gas applications Notice If a gas leak is present or suspected DO NOT attempt to find the cause yourself DO NOT try to light any appliance DO touch any electrical switch DO NOT use any phone in your building Leave the house immediately and make sure your family and pets leave also Leave the doors open for ventilation and contact the gas supplier a qualified service agency or the fire department Stay away from the house or building until the service call has been made the leak is corrected and a qualified agency has determined the area to be safe 4 Product Support Eccote
45. ress and hold UP or DOWN to raise or lower the temperature continuously When the unit is in use the set temperature can increase to 122 F but there is no limit to temperature decrease To increase the temperature more than 122 F the water will need to be shut off first NOTICE If inlet water temperature is high and set temperature is low the actual temperature might be higher than the set temperature and vice versa The display will read the set temperature if the water heater is not in use or there is no water flow If the water heater is in use or has water flow the display will read the actual temperature To view the set temperature in this condition press UP or DOWN and the set temperature will flash for 3 seconds The hottest temperature water will be at the hot water faucet closest to the water heater Always remember to test the water temperature with your hand before use and remember that hotter water increases the risk of scald injury Always supervise young children or others who are incapacitated f the water heater has been subjected to fire flood or physical damage turn off the manual gas shut off valve s and do not operate the water heater again until it has been checked by qualified personnel AX WARNING Should overheating occur or the gas supply fail to shut off turn off the manual gas control valve to the appliance AX NOTICE If the BATH control ls turned on the temperature setting
46. rol The remote control was set at TIO F before the water heater was shipped from the factory This is the recommended starting point Water temperatures above 120 F can cause severe burns or death from scalding The thermostat is adjusted to its lowest temperature position when shipped from the factory Be sure to read and follow the warnings outlined in this manual and on the label located on the water heater Mixing valves are available for reducing point of use water temperature by mixing hot and cold water in branch water lines Procedures for adjusting the thermostat for energy efficient operation at the minimum water temperature setting consistent with the consumer s needs Contact a licensed plumber or the local plumbing authority for further information See page 4 for details 1 This model can memorize and save the last set temperature the remote control with priority 2 If no remote control has priority the set temperature of the unit will be the same as the set temperature of the remote control which starts the water heater This water heater contains an electronically controlled thermostat From the factory the temperature range is between 90 F and 140 The remote control is factory preset to 10 F Toturn the remote control ON or OFF press the POWER button for more than 3 seconds To adjust the temperature to a required setting in priority mode press the UP or DOWN temperature button P
47. s printed in this manual Failure to do so can result in unsafe operation of the water heater resulting in property damage personal injury or death Should you have any problems reading or following the instructions in this manual STOP and get help from a qualified person WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life This appliance does not have a pilot It is equipped with an ignition device which automatically lights the burner Do not try to light the burner by hand BEFORE OPERATING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor Test all connections with a commercial leak detector or soapy water WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electric switch DO NOT use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions you cannot reach your gas supplier or fire department DO NOT return to your home until authorized by the gas supplier or fire department Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion DO NOT use th
48. talling the water heater Proper operation of the water heater requires air for combustion and ventilation Provisions for combustion and ventilation air must comply with referenced codes and standards Combustion and Ventilation Air This water heater is for OUTDOOR installation ONLY It must NOT be installed indoors or in a confined space Corrosive Atmospheres The air in beauty shops dry cleaning establishments photo processing labs and storage areas for liquid and powdered bleaches or swimming pool chemicals often contain such halogenated hydrocarbons NOTICE The water heater An air supply containing halogenated hydrocarbons may be safe should not be installed near to breathe but when it passes through a gas flame corrosive an air supply containing elements are released that will shorten the life of any gas halogenated hydrocarbons burning appliance Propellants from common spray cans or gas leaks from A C and refrigeration equipment are highly corrosive after passing through a flame The water heater warranty is voided when failure of the heater is due to operation in a corrosive atmosphere Inspect Shipment Inspect the water heater for possible damage Check the markings on the rating plate of the water heater to be certain the type of gas supplied corresponds to the water heater requirements Verify all included parts are present see below lur Care Manual Tankless Water Heater aaa men cum Gas App
49. tes do not allow exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights You may also have other rights that vary from State to State ELLO TEMP THE FUTURE OF EFFICIENCY PHONE 866 356 1992 EMAIL SUPPORT ECCOTEMP COM ADDRESS 315 A INDUSTRIAL RD SUMMERVILLE SC 29483 9 S PRODUCT SUPPORT ECCOTEMP COM HELP DESK SHOP ONLINE ECCOTEMP COM PRODUCT STORE LOCATOR ECCOTEMP COM LOCATOR n
50. the water heater outdoors as outlined in the Installation Instructions in this manual can result in unsafe operation of the water heater To avoid the risk of fire explosion or asphyxiation from carbon monoxide never operate this water heater unless it is installed properly and has an adequate air supply for proper operation Be sure to inspect the flue terminal for proper installation at initial start up and at least annually thereafter Refer to the Care and Cleaning section of this manual for more information regarding flue terminal inspection WARNING Gasoline as well as other flammable materials and liquids adhesives solvents paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combustible materials any where near or in the vicinity of a water heater or any other appliance Be sure to read and follow the labels on the water heater as well as the warnings printed Flammable Vapor Vapors from flammable Water heater has a main burner flame liquids will explode and catch fire The main burner flame causing death or severe burns 1 Can come on at any time and Do not use or store flammable products 2 Will ignite flammable vapors such as gasoline solvents or adhesives In the same room or area near the water heater 1 Cannot be seen 2 Are heavier than air 3 Go along way on the floor 4 Can be carried from othe
51. ug the relief valve outlet NOTICE After inspection maintenance and or cleaning ensure proper operation by turning on a hot water faucet Housekeeping HOW TO CLEAN THE WATER FILTER 1 Make sure the unit is OFF and the electrical power supply has been disconnected 2 Turn the water supply OFF to the heater 3 Unscrew the water filter and slide the filter out 4 DO NOT tap the filter as it may deform and or damage the filter 5 To remove severe dust use a soft brush and wash with running water 6 Return the filter to the water heater and screw in the filter water filter 7 Turn the electrical power supply and cold water supply ON to the water heater 15 Product Support Eccotemp com help desk Shop Online Eccotemp com products Store Locator Eccotemp com locator Housekeeping continued Before performing any Housekeeping tasks to this water heater be sure to turn the unit off and disconnect the power supply Vacuum around the water heater for dust dirt and lint on a regular basis Clean the water heater and remote control by using a damp soft cloth with a few drops of mild detergent and gently wiping the surfaces of the unit Wipe any remaining moisture with a dry soft cloth To ensure sufficient ventilation and combustion air supply proper clearances must be maintained The water filters should be cleaned on a monthly basis CLEANING THE WATER HEATER AND REMO TE CONTROL S
52. use improper and dangerous operation VERIFY PROPER OPERATION AFTER SERVICING 2 Product Support Eccotemp com help desk Shop Online Eccotemp com products Store Locator Eccotemp com locator Eccotemp Systems LLC Limited Warranty Information Model s 45HI LP 45HI NG 45H LP 45H NG Eccotemp hereby warrants this product to be free of material defects in materials and workmanship when installed and operated according to Eccotemp s installation and operating instructions This Limited Warranty extends to the original purchaser and subsequent owners but only while the product remains as the site of the original installation This Limited Warranty terminates if moved or reinstalled at a new location There are no warranties express or implied made or given other than contained in this Limited Warranty No agent employee or representative of Eccotemp has any authority to bind Eccotemp to any representation or warranty concerning the Product not contained in this Limited Warranty Eccotemp reserves the right and authority to change modify or alter this warranty at any given time Except as expressly set forth herein THERE ARE NO REPRESENTATIONS OR WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION 5 TO MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ANY GOODS SOLD HEREUNDER BUYER S EXCLUSIVE REMEDY IS LIMITED TO REPAIR OR REPLACEMENT OF THE GOODS SOLD AT ECCOTEMP S DISCRETION ECCOTEM
53. ve of any type restriction or reducer coupling should be installed in discharge line NOTICE Local codes govern the installation of relief valves If local codes require that a temperature and pressure relief valve should be installed the manufacturer recommends a type 40XL Watts T amp P relief valve or an equivalent model be used NOTICE Manual operation of relief valves should be performed at least once a year Turn off the electrical power and gas shutoff valve Lift and release lever on the relief valve and check the manual operation of the relief valve You should take precaution to avoid contact with the hot water coming out of the relief valve and to prevent water damage NOTICE If the relief valve on the system discharges periodically this may be due to thermal expansion in a closed water supply system Contact the water supplier or local plumbing inspector on how to correct theis situation Do not plug the relief valve Pressure Testing the Gas Supply System WARNING Install a gas pressure regulator in the gas supply line which does not exceed the maximum supply pressure DO NOT use an industrial type gas regulator Failure to isolate heater during pressure test can damage internal components voiding warranty The water heater must be isolated from the gas piping system by closing the manual gas shut off valve during any pressure testing of the gas supply piping at pressures equal to or less than 1 2 psi 14 w c 41 Pro

Download Pdf Manuals

image

Related Search

Related Contents

Page 1 > Spec1ñcatlons @i _ o .l Alim-nutons 12 .24 vocrwtc q. ` `  CP-13-06.2 9060 Classic Service Manual Model    T'nB TSGREEN07 mouse pad  Hsqldb User Guide    EFM104HR Wireless Modem Module User`s Manual  ../0905_20051215.display  Case Logic Attaché witch accessory pocket for 13” laptop  Hoja técnica  