Home
none WSSP3 Instructions / Assembly
Contents
1. DISCRETO nadan 1 1 2 in FNPT 1 1 4 in FNPT with adapter e Motor Type Permanent Split Capacitor with Thermal Overload Protection MOTOT DULY cocacola Continuous e Power coli SJTW 18AWG 3C 10ft NOTICE This unit is not designed to be used to pump salt water or brine Use with salt water or brine will void warranty CONSTRUCTION e Motor housing Die casting aluminum for WSSP3 Cast iron for WSSPC3 A A Thermoplastic for WSSP3 Cast iron for WSSPC3 e Impeller Reinforced thermoplastic Maximum Lift 23 ft 27 2 23 ft 7 46 5 38 6 A SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble operate or install the product If you have any questions regarding the product please call customer service at 1 800 346 7611 8 a m 5 p m EST Monday Friday WARNING e Do not pump flammable or explosive liquids such as oil gasoline kerosene ethanol etc Do not use in the presence of flammable or explosive vapors Using this pump with or near flammable liquids can cause explosion or fire resulting in serious personal injury and or property damage e Always disconnect the pump from its power source before installing inspecting maintaining or repairing e Do not stand in water when the pump is connected e Do not touch the pump housing while it is operating as the pump may be HOT and can cause serious skin burns
2. at the end of the thread 4 Place the pump in the sump make sure that nothing interferes with switch operation Notice Remove all small stones gravel mud or other debris from the sump pit before installing the pump The minimum diameter of the sump pit is 14 in for this pump The minimum depth of the pit is 16 in for this pump Construct the sump pit with tile concrete steel or plastic Check your local plumbing codes for approved materials and proper installation 5 Connect the discharge pipe to the other end of the rubber hose tighten the clamp with screwdriver Notice A rigid discharge pipe is recommended to prevent the pump from moving If a flexible discharge hose is used the pump must be secured in a manner that prevents the pump from moving If the pump is allowed to move the float switch could be restricted by the sump wall preventing the pump from turning on or off Notice After the installation of the necessary plumbing check valve and rubber hose follow the glue manufacture s instructions for safety precautions and curing time The pump is ready for operation 7 Check the pump by filling the sump with water and observe the pump s operation through one complete cycle and make sure the pump cannot move in the sump and float switch moves freely up and down WARNING The tether length distance between the float and clamp see picture above is factory pre set 4 in PLEASE DO NOT ADJUS
3. e Do not disassemble the motor housing The motor has NO repairable internal parts and disassembling may cause oil leakage or dangerous electrical wiring issues CAUTION e This pump is designed for home sump applications The pump is equipped with a 3 prong grounding type power cord The ball bearings on the motor shafts never need to be lubricated e This pump is made of high strength corrosion resistant materials It will provide trouble free service for a long time when properly installed maintained and used However inadequate electrical power to the pump dirt or blockage by ice or debris may cause the pump to fail eventually bringing about additional water damage To minimize the potential for water damage due to pump failure please carefully read the manual and follow the instructions regarding common pump problems and remedies or call one of our pump experts at 1 800 346 7611 e This pump has not been tested or approved for use in swimming pools or in salt water marine areas It is also not engineered to be run continuously as a fountain or waterfall pump Because this pump has an oil filled motor it should NOT be used in water containing fish Pump only water with this pump e For safety the pump motor has an automatic resetting thermal protector that automatically will turn off the pump if it becomes too hot Overuse of this feature will damage the pump and will void the warranty e Once the thermal prot
4. T IT FREELY to avoid any failure to pump OPERATION INSTRUCTIONS Do not handle this pump or plug in or unplug this pump with wet hands or while standing in water unless you are certain all power has been turned off to the pump Remember the pump should be connected only to a properly grounded GFCI outlet Do not handle this pump or plug in or unplug this pump with wet hands or while standing in water unless you are certain all power has been turned off to the pump Remember the pump should be connected only to a properly grounded GFCI outlet Running the pump without sufficient water will damage the pump and void the pump s warranty 1 Make certain the pump is submerged in water Running the pump dry can damage to the shaft seal 2 Plug the pump into a 115V GFCI power outlet The pump will start operating if the float switch moves over the pump top The water will be pumped out When the TROUBLESHOOTING water lowers to certain level the float switch will turns off the pump 3 The motor is equipped with an automatically resetting thermal overload protector If the motor gets too hot the overload protector will shut off the pump before it is damaged When the motor has cooled sufficiently the overload protector will reset and the motor will restart NOTICE If the overload protector stops the pump repeatedly disconnect the power from the pump and check to find the problem Low voltage a long extension cord clogg
5. WATER OWNER S MANUAL 1 3 HP SUBMERSIBLE SUMP PUMP SOURCE Model FWSSPC3 Model FWSSP3 WATER SOURCE 2053 S E 37 St Suite A Grimes lA 50111 1 800 346 7611 PREINSTALLATION CHECK Inspect this pump before it is used Occasionally pumps can be damaged during shipping If the pump or components are deformed cracked or there is an oil leak call us Toll Free at 1 800 346 7611 or e mail sales watersourceusa com Monday Friday between 8 00 a m 4 30 p m EST Do not return the pump to the store ATTEMPTING TO USE A DAMAGED PUMP can result in personal injury or death DESCRIPTION This pump is designed for home sump applications The pump is built with thermal overload protection and auto reset The pump is equipped with a 3 prong grounding type power cord The ball bearings on the motor shafts never need to be lubricated Pump only water with this pump It is also not engineered to be run continuously as a fountain or waterfall pump And also it should NOT be used in water containing fish This pump has not been tested or approved for use in swimming pools or in salt water marine areas PERFORMANCE GPM of Water Total Feet Meters of Lift 5 ft 1 5 m 10 ft 3 m 15 ft 4 6 m ene 6 1 m wss w SPECIFICATION e Power supply required 115V 60 HZ e Water temperature range Max 77 F 25 C e Individual branch circuit required 15 Amp minimum
6. ector detects that the pump has cooled to a safe temperature it will allow the pump to operate normally If the pump is plugged in it may restart unexpectedly Additional Safety Precautions 1 Know the pump applications limitations and potential hazards 2 Make certain the electrical power source is adequate for the requirements of the pump 3 ALWAYS disconnect the power to the pump before servicing 4 Release all pressure drain all water within system before servicing any component 5 Secure discharge line before starting pump An unsecured discharge line will whip possibly causing personal injury and or property damage 6 Secure the pump on a solid base to keep the pump vertical and above mud and sand during operation to maximize pumping efficiency and prevent clogging and premature pump failure 7 Check that all pipe connections are tight to minimize leaks 8 Connect the pump DIRECTLY to a grounded GFCI outlet 9 Extension cords may not deliver sufficient voltage to the pump motor Extension cords present a life threatening safety hazard if the insulation becomes damaged or the connection ends fall into water 10 Make certain the electrical circuit to the pump is protected by a 15 Amp or larger fuse or circuit breaker 11 Periodically inspect the pump and system compo nents to be sure the pump inlets are free of mud sand and debris DISCONNECT THE PUMP FROM THE POWER SUPPLY BEFORE INSPECTING 12 Do n
7. ed impeller screen blocked by debris or water that is too hot can cause motor overheating Do not disassemble the motor housing This pump has NO repairable internal parts and disassembling may cause leakage or dangerous electrical wiring conditions If you have any questions regarding the product please call customer service at 1 800 346 7611 8 a m 5 p m EST Monday Friday 3 Vote 1 3 Impeller g LS o Possible Cause Corrective Action Blown fuse Replace fuse Tripped breaker Reset breaker Plug disconnected Secure plug Corroded plug Clean plug prongs Pump does Thermal overload Unplug for 30 minutes then plug in not start or run Motor failed Call 1 800 346 7611 Float switch failed Please call us at 1 800 346 7611 for a replacement float switch or go to the store where you purchased this pump to purchase a new float switch Float switch obstructed Make sure the float switch has room to move and is not getting caught on any obstructions Make sure your pit is at least 14 in wide Pump operates Screen blocked 1 Clean screen but pumps little Impeller loose on shaft 2 Reassemble impeller See Picture above or no water Impeller broken 3 Call 1 800 346 7611 WARRANTY This product is warranted against manufacturing defects for a period of 12 months from the date of purchase Any misuse abuse or modification automatically voids this warranty Water Source LLC
8. ot handle pump or pump motor with wet hands or when standing on wet or damp surface or in water 13 Wear safety glasses at all times when working with pumps 14 Follow all electrical and safety codes particularly the National Electrical Code NEC and in the workplace the Occupational Safety and Health Act OSHA 15 This unit is designed only for use on 115 volts single phase 60 Hz and is equipped with an approved 3 conductor cord and 3 prong grounded plug DO NOT REMOVE THE GROUND PIN UNDER ANY CIRCUMSTANCES The 3 prong plug must be directly inserted into a properly installed and grounded 3 prong grounding type receptacle Do not use this pump with a 2 prong wall outlet Replace the 2 prong outlet with a properly grounded 3 prong receptacle a GFCI outlet installed in accordance with the National Electrical Code and local codes and ordinances All wiring should be performed by a qualified electrician 16 Protect the electrical cord from sharp objects hot surfaces oil and chemicals Avoid kinking the cord Do not use damaged or worn cords 1 Wrap threads of the 1 1 4 in adapter included PREPARATION with thread tape then screw the adapter into pump A outlet hand tight plus 1 turn with a wrench WARNING Always use handle to lift pump Notice If the discharge pipe you will connect is 1 1 2 in Never usepower cord to lift pump To avoid skin burns no need to screw the 1 1 4 in adapter into the pump unplug and all
9. ow time for the pump to cool after periods outlet just screw a 1 1 2 in check valve into the pump of extended use outlet directly Before beginning assembly of product make sure all parts are present Estimated Assembly Time New installation 30 minutes or longer if installing new sump pit Materials Required for Assembly not included Rubber hose 6 10 with stainless steel clamps Check valve PVC pipe PVC elbow Thread Tape PVC Purple Primer and PVC Cement Note After the installation of the necessary plumbing check valve and rubber hose follow the glue manufacturer s instructions for safety precautions and curing time The pump is ready for operation 2 Install a check valve not included into the pump The pump should rest on a level solid base or adapter if using 1 1 4 in pipe Do not suspend the pump by the discharge hose or power cord drill a 1 8 in 3 2mm hole Keep the pump inlet screen clear A Do not install pump directly on sand or dirt INSTALLATION INSTRUCTIONS Always use the handle to lift the pump Never use the power cord to lift the pump To avoid skin burns unplug the pump and allow time for it to cool after periods of extended use 3 Connect a short length 6 10 in of rubber hose to the check valve Notice For cast iron sump pump WSSPC3 if your check valve is not equipped with an air bleed hole to prevent airlocking pump drill a 1 8 in 3 2 mm hole
10. will repair or replace the pump if in its sole determination the pump failed due to defects in materials or workmanship WARRANTY EXCLUSIONS 1 Neither Water Source LLC nor the store that sold this pump shall in any event be liable for any labor or similar expenses incurred in removing or repairing this pump 2 Water Source LLC specifically disclaims any implied warranties of merchantability and fitness for a particular purpose 3 In no event shall Water Source LLC be liable for consequential incidental or special damages resulting from or related in any manner to any components or accessories 4 Water Source LLC disclaims all liability for improper installation or improper use of this product some states do not allow the exclusion or limitation of incidental or consequential damages The above limitations and exclusions may not apply to you In addition to the rights given you by this warranty you may also have other rights which vary from state to state For warranty claims DO NOT RETURN PUMP TO THE STORE Call our customer service department at 1 800 346 7611 Monday Friday 8 00 a m 5 00 p m EST Printed In China
Download Pdf Manuals