Home
Little GIANT 506055 Instructions / Assembly
Contents
1. 1 888 572 9933 Para la ayuda t cnica por favor p ngase en contacto 1 888 956 0000 www LittleGiantPump com CustomerService WTS fele com Form 993801 09 24 2009 2007 Franklin Electric Co Inc Little Giant is a registered trademark of Franklin Electric Co Inc
2. NOT INCLUDED he 2 VENT PIPE FILTER ACCESS COVER WITH O RING COVER O RING 8 FT POWER CORD 8 FT POWER CORD CORD GROMMET INCLUDED Pump Sediment or lint can clog pump and cause improper operation If necessary remove pump and pull off the pressed in screen Clean using a mild detergent and water and reinstall Plastic pump base may also be removed to clean around impeller and inside base Remove the six base screws and clean base using a mild detergent and water Do not remove impeller When reinstalling base be sure seal ring is seated properly in groove and torque screws to 10 15 in lbs See pump manual for other information For any other pump repair return the pump to a Little Giant authorized service center 1 1 2 CHECK VALVE 1 1 2 UNION 1 1 2 DISCHARGE PIPE BASIN COVER BASIN 1 1 2 DISCHARGE PIPE 3 8 DIA BLEED HOLE IN DISCHARGE PIPE LITTLE GIANT PUMP MODEL 6 CIA 10 63 DIA 13 88 DIA 1 1 2 CHECK VALVE 1 1 2 UNION 1 1 2 DISCHARGE PIPE BASIN COVER BASIN L 1 1 2 DISCHARGE PIPE 56 3 8 DIA BLEED HOLE IN DISCHARGE PIPE LITTLE GIANT PUMP MODEL 6 CIA AANEEN EEEEEEEN Y A ITEMS NOT INCLUDED WITH WRS 6 BASIN KIT 13 88 DIA Figure 2 REPLACEMENT PARTS ITEM DESCRIPTION Screw 1 4 20 x 1 2 5 Discharge pipe Pump 6 CIA 118V Cord grommet Intake scr
3. then close off tube with thumb plug into wall outlet f pump works proceed to check switch if not fault is in pump or power supply Le moteur de la pompe ne s arr te pas Remarque avant de contr ler le fonctionnement automatique v rifier que la pompe fonctionne en manuel Pour cela faire un vide dans le tube de purge pr s de la prise fermer ensuite le tuyau avec le pouce et brancher dans la prise murale Si la pompe fonctionne v rifier le commutateur si elle ne fonctionne pas c est la faute de la pompe ou du bloc d alimentation La bomba no se apaga Nota antes de buscar aver as en el control autom tico verifique si la bomba funciona con control manual Para hacer esto descon ctela de la l nea del enchufe del interruptor accionado por el flo tador Conecte el cable el ctrico de la bomba a una toma en la pared Si la bomba funciona proceda a inspeccionar el inter ruptor si no la falla est en la bomba o el suministro de electricidad Pump runs but does not discharge liquid La pompe fonctionne mais il n y a pas d coulement de liquide La bomba fun ciona pero no descarga l quido Pump does not deliver rated capacity La pompe ne pompe pas le volume normal e La bomba no impele a su capacidad nor mal PROBABLE CAUSES CAUSES PROBABLES CAUSAS PROBABLES Diaphragm switch C est le commutateur de diaphrag me Interruptor del diafragma Weak or hardened rubber diaphragm Le caou
4. CONSEQUENTIAL OR SPECIAL DAMAGES SUCH AS BUT NOT LIMITED TO DAMAGE TO OR LOSS OF OTHER PROPERTY OR EQUIPMENT LOSS OF USE OF EQUIPMENT FACILITIES OR SERVICE LOSS OF PROFIT OR SALES COST OF PURCHASES OR REPLACEMENT GOODS CLAIMS OF CUSTOMERS OF THE PURCHASER FAILURE TO WARN AND OR INSTRUCT LOSS OF OTHER PRODUCTS OR COSTS OF ENVIRONMENTAL REMEDIATION OR DIMINUTION IN PROPERTY VALUE THE REMEDIES OF THE PURCHASER SET FORTH HEREIN ARE EXCLUSIVE AND THE LIABILITY OF THE COMPANY SHALL NOT EXCEPT AS EXPRESSLY PROVIDED HEREIN EXCEED THE PRICE OF THE PRODUCTS UPON WHICH SUCH LIABILITY IS BASED DAMAGES AS SET FORTH IN THIS PARAGRAPH SHALL BE REASONABLY MITIGATED TO THE EXTENT POSSIBLE THIS PARAGRAPH SHALL ALSO APPLY TO ALL DAMAGES RESULTING FROM CONDITIONS SET FORTH IN SECTION Ill ABOVE AND 1 DEFECTS IN PRODUCT PROTOTYPES OR REPLACEMENT PART PROTOTYPES THAT HAVE NOT BEEN PUT INTO PRODUCTION CIRCULATED AND SOLD BY THE COMPANY AND OR 2 DEFECTS THAT WERE NOT FOUND AT THE TIME OF SALE DUE TO SCIENTIFIC AND TECHNOLOGICAL REASONS This Limited Warranty gives you specific legal rights You may have other rights which vary according to the applicable laws and regulations Where any term of this warranty is prohibited by such laws it shall be null and void but the remainder of this warranty shall remain in full force and effect DISCLAIMER Any oral statements about the product made by the seller the Company the representatives or any other parties
5. 3 Any product that has been subject to misuse misapplication neglect alteration accident abuse tampering acts of God including lightning acts of terrorism acts of war fire improper storage or installation improper use improper maintenance or repair damage or casualty or to an excess of the recommended maximums as set forth in the product instructions Any product that is operated with any accessory equipment component or part not specifically approved by the Company 5 Use of replacement parts not sold by the Company the unauthorized addition of non Company products to other Company products and the unauthorized alteration of Company products 6 Products damaged by normal wear and tear normal maintenance services and the parts used in connection with such service or any other conditions beyond the control of the Company 7 Any product that has been used for purposes other than those for which it was designed and manufactured 8 Any use of the product where installation instructions and or instructions for use were not followed 9 Products connected to voltage other than indicated on nameplate 10 Products where the pump was exposed to any of the following sand gravel cement grease plaster mud tar hydrocarbons hydrocarbon derivatives oil gasoline solvents etc or other abrasive or corrosive substances 11 Products in which the pump has been used to pump or circulate anything other than fresh water at room t
6. Durant le fonctionnement normal du syst me la pompe puisard est immerg e donc invisible De plus pendant les orages il pourrait y avoir de l eau autour de la pompe C est pourquoi il faut faire attention si on travaille pr s de celle ci L alimentation lectrique doit tre coup e avant de toucher la pompe de la r parer ou d en faire l entretien Afin de r duire le risque d lectrocution faire preuve d une grande prudence pendant le remplacement desfusibles Ne pas avoir les pieds dans l eau pendant le remplacement des fusibles et ne pas ins rer le doigt dans les culots de fusibles Ne pas faire fonctionner la pompe dans un puisard sec Une temp rature lev e la surface de la pompe r sultera d une telle utilisation et pourrait causer des br lures ainsi que de graves dommages la pompe Ne pas lubrifier le moteur Le bo tier de la pompe est scell De l huile di lectrique de haute qualit sans eau a t mise dans le bo tier en usine L utilisation d un autre type d huile pourrait causer FOR AUTOMATIC PUMPS PROPER PLUG INSTALLATION IS VENT TUBE DOWN Figure 1 un choc lectrique grave ou gravement endommager la pompe ou les deux Le bo tier du moteur de cette pompe est rempli d une huile di lectrique pour un transfert de chaleur optimal et une lubrification durable des paliers L utilisation d un autre type d huile pourrait causer des dommages et annuler la garantie Ce lubrifiant es
7. ET L ACHETEUR CONVIENT QU IL NE DISPOSE D AUCUN AUTRE RECOURS L acheteur doit s assurer que la pompe convient l usage projet il assume aussi tout risque et toute responsabilit relativement cet usage Certaines juridictions ne permettent pas la limitation de la dur e d une garantie ou l exclusion ou la limitation de responsabilit pour des dommages indirects ou accessoires Par cons quent il est possible que la limitation ou l exclusion indiqu e pr c demment puisse ne pas tre applicable Cette garantie vous donne des droits particuliers et peut tre d autres d pendamment des juridictions en vigueur Le code national de l lectricit et autres codes semblables d autres pays exigent l installation d un interrupteur avec mise la terre GFI sur le circuit d alimentation de la fontaine pour toute installation dont la tension est sup rieure 15 volts Nous offrons de tels interrupteurs avec diff rentes longueurs de fil et nous recommandons que chaque pompe soit reli e un interrupteur de ce type GARANTIA LIMITADA El producto que Little Giant le ofrece est garantizado a estar en perfectas condiciones al momento de salir de la f brica El producto est garantizado contra materiales y fabricaci n defectuosa por un per odo de 24 meses a partir de la fecha de compra o 30 meses a partir de la fecha de fabricaci n lo que ocurra primero En ausencia de otra prueba apropiada de la fecha de compra la fecha de vigen
8. Remove pump and clean basin using a mild detergent and water Reassemble in reverse order Torque screws item 21 18 20 in lbs 3 If pump alignment plate is removed it must be reinstalled per plate alignment diagram Figure 1 4 Sediment or lint can clog pump and cause improper operation If necessary remove pump and pull off the pressed in screen clean using a mild detergent and water and reinstall Plastic pump base may also be removed to clean around impeller and inside base Remove the six base screws and clean base using a mild detergent and water Do not remove impeller When reinstalling base be sure seal ring is seated properly in groove and torque screws to 12 17 in lbs See pump manual for other information For any other pump repair return the pump to a Little Giant authorized service center 5 This unit is permanently lubricated Oiling is not required Do not in any case open the sealed portion of the unit or remove housing screws 6 Remove screws item 4 that hold base to volute and clean impeller and volute passage Do not use strong solvents on impeller 7 Be sure impeller turns freely after cleaning WARNING DO NOT REMOVE IMPELLER REMOVAL OF IMPELLER REQUIRES SPECIAL TOOLS AND IS TO BE DONE ONLY BY AN AUTHORIZED SERVICE CENTER 8 When reinstalling base be sure seal ring is seated properly in groove and torque screws item 4 to 10 15 in lbs 9 DO NOT REMOVE MOTOR HOUSING COVER WARRANTY IS VOID IF MO
9. and workmanship for a period of 24 months from date of purchase or 30 months from date of manufacture whichever occurs first In the absence of other suitable proof of the purchase date the effective date of this warranty will be based upon the date of manufacture plus two years Any product that should fail for either of the above two reasons and is still within the warranty period will be repaired or replaced at the option of Little Giant as the sole remedy of buyer For our customers in the CONTINENTAL UNITED STATES Please return the defective unit postage paid to the factory at 301 N MacArthur Oklahoma City OK 73127 6616 All defective product returned under warranty will be fully inspected to determine the cause of failure before warranty is approved For our customers located elsewhere it is not economical due to duties and freight to return the pump to the factory for inspection Please return the defective unit to any authorized distributor or dealer with a brief written explanation of the problem If there are no apparent signs of customer abuse unit will be repaired or replaced If dispute arises over replacement of the pump the distributor or dealer is to segregate such items and hold for inspection by a representative of Little Giant or notify factory with details of the problem for factory disposition and settlement of warranty claim DISCLAIMER THE FOREGOING WARRANTY IS AN EXCLUSIVE WARRANTY IN LIEU OF ANY OTHER EXPRESS W
10. avez achet a t soigneusement fabriqu avec des mat riaux de la plus haute qualit et a t concu pour durer longtemps et offrir un service fiable Les produits sont soigneusement test s inspect s et emball s afin d en assurer la s curit de fonctionnement et une livraison en bonne condition V rifier attentivement le produit afin de vous assurer qu il n a pas t endommag pendant le transport S il est endommag veuillez contacter l entreprise qui vous l a vendu Si une r paration ou un remplacement est requis elle vous pr tera assistance LIRE ATTENTIVEMENT CES DIRECTIVES AVANT DE PROC DER A L INSTALLATION L UTILISATION OU L ENTRETIEN DU PRODUIT SE FAMILIARISER AVEC LES APPLICATIONS LES LIMITES ET LES RISQUES POTENTIELS DU PRODUIT ASSURER SA PROPRE PROTECTION ET CELLE DES AUTRES EN SUIVANT TOUTES LES R GLES DE S CURIT LE NON RESPECT DE CES DIRECTIVES PEUT ENTRA NER DES BLESSURES ET OU DES DOMMAGES MAT RIELS DIRECTIVES DE S CURIT W Ma AAVERISSEMENTA MISE EN GARDE afin de r duire le risque de choc lectrique d brancher la pompe avant d en faire l entretien Bien lire les instructions du guide de s curit Le non respect des consignes de s curit peut causer de graves blessures ou des dommages la propri t ou les deux V rifier les codes du b timent et de l lectricit avant l installation Celle ci doit tre conforme aux r glements contenus dans ces codes
11. de purge de aspiraci n ocluidos Despeje el tubo de aspiraci n de cualquier obstrucci n la pompe fonctionne en manuel Pour cela faire un vide dans le tube de purge pr s de la prise fermer ensuite le tuyau avec le pouce et brancher dans la prse murale Sila pompe Dirt or sediment lodged between retainer ring and rubber Clean area around rubber diaphragm Nettoyer le contour fonctionne v rifier le commutateur si elle ne fonctionnel 5 A FA A diaphragm causing contacts to remain closed Boue ou de caoutchouc du diaphragme Limpie el rea que rodea el r sidus log s entre le jonc et le caoutchouc du diaphragme diafragme de caucho emp chent les contacts de s ouvrir El sucio o sedimento pas c est la faute de la pompe ou du bloc d alimentation La bomba no se apaga Nota antes de buscar aver as en el atrapado entre el anillo de retenci n y el diafragma de caucho causa que los contactos permanezcan cerrados control autom tico verifique si la bomba funciona con control manual Para hacer esto descon ctela de la l nea del enchufe del interruptor accionado por el flotador Conecte el cable el ctrico de la bomba a una toma en la pared Si la bomba funciona proceda a inspeccionar el interruptor si no la falla est en la bomba o el suministro de electricidad Pump is air locked Poche d air dans la pompe Burbujas de aire en la bomba Shut power off for approximately 1 minute then restart Repeat sever
12. do not constitute warranties shall not be relied upon by the user and are not part of the contract for sale Seller s and the Company s only obligation and buyer s only remedy shall be the replacement and or repair by the Company of the product as described above Before using the user shall determine the suitability of the product for his intended use and user assumes all risk and liability whatsoever in connection therewith GARANTIE LIMIT E LA PRESENTE GARANTIE ENONCE LA SEULE OBLIGATION DE LA SOCIETE ET LE RECOURS EXCLUSIF DE L ACHETEUR POUR UN PRODUIT D FECTUEUX Franklin Electric Company Inc et ses filiales ci apr s la Soci t garantit que les produits accompagn s de cette garantie sont exempts de d fauts de mat riaux ou de fabrication de la Soci t existant au moment de la vente par la Soci t et qui se produisent ou existent pendant la p riode de garantie applicable Tout distributeur sous distributeur destinataire utilisateur final et ou consommateur en acceptant la r ception des produits convient que le distributeur sous distributeur destinataire utilisateur final et ou consommateur accepte express ment d tre li par les termes de la garantie qui y sont nonc s P RIODE DE GARANTIE APPLICABLE Les produits accompagn s par cette garantie doivent tre couverts par cette Garantie Limit e pour une p riode de 24 mois compter de la date d achat originale par le consommateur En l absence de pr
13. et la responsabilit dans n importe quel cadre avec lequel le produit sera associ GARANT A LIMITADA ESTA GARANT A ESTIPULA LA NICA OBLIGACI N DE LA COMPA A Y EL NICO RECURSO QUE TENDR EL COMPRADOR ANTE UN PRODUCTO DEFECTUOSO Franklin Electric Company Inc y sus subsidiarias en adelante la Compa a garantizan que los productos que est n acompa ados por esta garant a se encuentran libres de defectos de material o mano de obra de la Compa a que existan al momento de la venta por parte de la Compa a y que ocurran o aparezcan dentro del per odo de validez de la garant a Cualquier distribuidor subdistribuidor receptor usuario final o consumidor acuerdan que al aceptar el recibo del producto el distribuidor subdistribuidor receptor usuario final y o consumidor impl citamente aceptan que est n obligados a los t rminos de la garant a que aqu se establecen I PER ODO DE GARANT A APLICABLE Los productos que est n acompa ados por esta garant a ser n cubiertos por esta Garant a Limitada por un per odo de 24 meses desde la fecha original de compra por parte del consumidor Ante la falta de pruebas adecuadas respecto de la fecha de compra el per odo de garant a de este producto entrar en vigencia a partir de su fecha de fabricaci n 4 Il INSTRUCCIONES APLICABLES A ESTA GARANT A LIMITADA Los consumidores que deseen presentar un reclamo de garant a deber n devolver los productos acompa ados p
14. obstruction du bassin par des d bris les odeurs et les risques d accidents corporels TYPICAL INSTALLATION Separate protected and grounded service outlet 4 ft from floor min INSTALLATION TYPE Prise de courant de mise la terre INSTALACION TIPICA protection s par e une distance minimale de 1 2 m du sol Tomacorrientes de servicio conectado atierra y protegido separado por lo menos a 1 2 m del suelo Discharge pipe no smaller than pump outlet La canalisation de refoulement doit tre plus petite que la sortie de pompe Tubo de descarga que no sea m s wip pequeno que la salida de la bomba Check valve Sump Cover alce Clapet de retenue G de puisard Verifique v lvula o Cubierta del N o sumidero SK 1 NES nn SN D 1 2 m min Eos ANN Min 1 2 m Pat 34 Union or Hose NS y om Connection DAS AS Branchement du tuyau 3 16 Dia Bleed INNS NS 34 Uni n o conexi n de Hole in Discharge Pipe lt x 2 7 manguera Trou de d gagement 0 15 diam 0 48 cm po sur le tuyau d coulement Agujero de purgado d di metro 5 en la tuber a BOOS de descarga Sump Pit 18 Min Dia X 24 Deep Bassin du puisard diam 45 7 cm min X prof 61 0 cm Foso sumidero de 457 2 mm de di metro minimo x 609 6 mm de profundidad 7 10 on level 17 8 cm 25 4 cm niveau 1 4 off level 1778mma2540mm 2 5 cm a 10 2 cm hors niveau Typical poured concrete bottom en el nivel 25 4 mm a 101 6 mm Fond e
15. rement attentif au moment de commander des pi ces Toujours donner le num ro de catalogue de votre pompe lors de la commande de pi ces Votre nouvelle pompe Little Giant a t fabriqu e avec les meilleurs mat riaux et avec le plus grand soin Elle a t con ue pour foncionner bien et longtemps Les pompes Little Giant sont soigneusement emball es et test es pour assurer une livraison et un fonctionnement sans probl mes Lorsque vous recevez votre pompe examinez la attentivement pour vous assurer qu il n y a pas eu de pi ce cass e ou endommag e pendant l acheminement S il y a eu des d gats prenez en note et signalez le au magasin o vous avez achet la pompe Ils vous aideront pour le remplacement ou la r paration si n cessaire Cette pompe est con ue pour pomper de l eau NE POMPEZ PAS de produit chimique de solvant d eau sal e ou de liquides pais tels que des huiles ou de la graisse BIEN LIRE LES INSTRUCTIONS AVANT D INSTALLER DE FAIRE FONCTIONNER OU D ENTRETENIR LA POMPE LITTLE GIANT IL FAUT CONNA TRE L APPLICATION LES LIMITESET LES DANGERS POTENTIELS DE LA POMPE PROT GEZ VOUS ET LES AUTRES EN RESPECTANT TOUTES LES NORMES DE S CURIT LE NON RESPECT DES INSTRUCTIONS PEUT CAUSER DES ATTEINTES AUX PERSONNES OU LA PROPRI T GARDER LE PR SENT DOCUMENT POUR R F RENCE ULT RIEURE Position the alignment plate inside the basin as shown This will position the mounting holes properly when inst
16. un circuito de ramal independiente No utilice cables de extensi n No corte el enchufe del cable Si se corta el enchufe o se acorta el cable la garanti ser nula Si el cable viene dotado de hilos conductores forrados como ocurre en los modelos de 230 voltios cerci rese de que los hilos conductores se encuentren conectados correctamente a una fuente de electricidad El hilo verde o amarillo es el de puesta a tierra el hilo azul o blanco y el marr n o negro son hilos con corriente CONSULTE LAS ILUSTRACIONES DE LA HOJA DE INSTRUCCIONES PARA MONTAR Y DESMONTAR CORRECTAMENTE SU BOMBA LITTLE GIANT Verifique los c digos locales de construcci n y el ctricos antes de la instalaci n La instalaci n debe estar de acuerdo con los reglamentos as como con el C digo El ctrico Nacional National Electrical Code NEC m s reciente Enchufe a un recept culo conectado a tierra con el tubo del respiradero indicando hacia abajo Este debe mantenerse sin obstrucciones para el funcionamiento apropiado de la bomba Si la bomba se instala en un s tano la conexi n de enchufe debe estar a cuatro pies o m s por encima del nivel del piso especialmente si el s tano se inunda Aseg rese de que las conexiones el ctricas no puedan ser alcanzadas por la subida de las aguas En ninguna circunstancia debe estar ubicado el tomacorriente donde el agua lo pueda inundar o sumergir FUNCIONAMIENTO Determine la ubicaci n apropiada para la unid
17. un colector de aguas lluvias seg n las normas locales de ca er as El tubo de descarga debe ser lo m s corto posible y tener el menor n mero posible de codos El tubo de descarga deber tener el mismo di metro de la descarga para reducir las p rdidas por fricci n de los tubos Un tubo m s peque o restringir el rendimiento y disminuir la capacidad de la bomba La bomba de sumidero est dotada de un a descarga de rosca hembra de 1 pulgada y media y un casquillo reductor FNPT de una pulgada y cuarto 3 Coloque siempre una uni n en el tubo de descarga exactamente encima del fondo del sumidero para permitir el retiro f cil de la bomba con el fin limpiarla o repararla 4 En situaciones en las cuales la tuber a es larga la descarga vertical se encuentra a m s de 7 u 8 pies o se ha suministrado un peque o foso se recomienda el uso de una v lvula de retenci n para evitar el reflujo del agua al sumidero Cuando se utilice una v lvula de retenci n perf rese un agujero de descompresi n de un di metro de 1 8 3 16 de pulgada en el tubo de descarga Este agujero deber encontrarse debajo de la l nea de la superficie del suelo entre la descarga de la bomba y la v lvula de retenci n A menos que se proporcione tal agujero de descompresi n la bomba podr a llenarse de burbujas de aire y no bombear el agua aunque s funcionar 5 Una con cinta adhesiva de electricista el cable de alimentaci n de corrient
18. vil conectada Saque la bomba y limpiela Pump is air locked Pr sence d une poche d air dans lalSee corrective action above Voir ci dessus la solution Rem tase a la soluci n anterior pompe La bomba est llena de burbujas de aire Pump does not deliver rated capacity La pompe ne pompelLift too high for pump Aspiration trop puissante pour la Check rated pump performance V rifier les caract ristiques pas le volume normal La bomba no impele a su capacidad pompe Altura de impulsi n excesiva para la bomba techniques de la pompe Verifique el rendimiento normal de la bomba Low voltage speed too slow Voltage et vitesse pas assez Check for proper supply voltage to make certain it corresponds i e Voltaje demasiado bajo velocidad demasiado to nameplate voltage S assurer que le voltage correspond bien celui mentionn sur la plaque Verifique que el suministro de electricidad sea adecuado para cerciorarse de que corresponde al voltaje indicado en la placa del fabricante Impeller or discharge pipe is clogged Obstruction de la roue Pull pump and clean Check pipe for scale or corrosion aubes ou du tuyau d coulement La rueda m vil en el tubo Tirer la pompe pour la nettoyer V rifier la pr sence de de descarga est oclu da d p ts ou de corrosion dans les tuyaux Saque la bomba y l mpiela Inspeccione el tubo en busca de capas de xido o corrosi n Impeller wear due to abrasives
19. 7 Limpie la rejilla de la toma utilizando un detergente ligero y agua Examine el anillo anular tipo O y si est deformado reempl celo con uno nuevo Vea Listado de piezas de repuesto Dep sito Se puede acumular sedimento en el dep sito y ello causa que la bomba funcione mal Quite 10 tornillos de 1 4 20 de la cubierta Saque la arandela aislante y afloje los cables para que tengan holgura y luego saque la cubierta Saque la bomba y limpie el dep sito con un detergente suave y agua Vuelva a armar en orden inverso Apriete los tornillos con una torsi n de 21 a 23 cm Kg Si se saca la placa de alineaci n de la bomba debe volver a instalarse seg n el diagrama de alineaci n de la bomba Bomba El sedimento o las hilachas pueden tapar la bomba y causar que funcione mal Si es necesario saque la bomba y quite la rejilla instalada a presi n l mpielo con un detergente suave y agua y instale de nuevo La base pl stica de la bomba tambi n puede sacarse para limpiar alrededor del impulsor y dentro de la base Saque los seis tornillos de la base y limpie la base con un detergente suave y agua No saque el impulsor Cuando instale de nuevo la base aseg rese que el anillo de sellado est apropiadamente asentado en la ranura y apriete los tornillos con una torsi n de 12 a 17 cm Kg Vea el manual de la bomba para obtener informaci n adicional Para cualquier otro tipo de reparaci n de la bomba env e la bomba a un centro de servicio
20. 8 Toute utilisation du produit pour laquelle les instructions d installation et ou les instructions d utilisation n ont pas t suivies 9 Les produits branch s une tension autre que celle indiqu e sur la plaque signal tique 10 Les produits dont la pompe a t expos e l un des suivants sable gravier ciment graisse pl tre boue goudron hydrocarbures d riv s d hydrocarbures huile essence solvants etc ou d autres substances abrasives ou corrosives 11 Les produits dans lesquels la pompe a t utilis e pour pomper ou faire circuler des liquides autres que de l eau douce temp rature ambiante 12 Des produits dans lesquels la pompe a t autoris e fonctionner sec alimentation en liquide coup e 13 Les produits dans lesquels la carcasse de moteur scell e a t ouverte ou le produit a t autrement d mont par le client 14 Les produits dans lesquels le cordon a t coup une longueur de moins de trois pieds La Soci t se r serve le droit tout moment et de temps autre d apporter des changements la conception et ou des am liorations ses produits sans pour autant imposer une quelconque obligation sur elle m me d apporter des modifications ou des am liorations correspondantes dans ou sur ses produits d j fabriqu s et ou d j vendus La Soci t se r serve galement le droit de remplacer des pi ces ou des composants d une qualit sensiblement gale dans tou
21. ARRANTIES ANY IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT EITHER APPLIES TO A PUMP SHALL BE LIMITED IN DURATION TO THE PERIODS OF THE EXPRESS WARRANTIES GIVEN ABOVE Warranty will be VOID if any of the following conditions are found 1 Sealed motor housing opened Product connected to voltage other than indicated on nameplate Cord cut off to a length less than three feet Pump allowed to operate dry fluid supply cut off Pump used to circulate anything other than fresh water at approximately room temperature 6 Product abuse by customer Any oral statements about the product made by the seller the manufacturer the representatives or any other parties do not constitute warranties shall not be relied upon by the user and are not part of the contract for sale Seller s and manufacturer s only obligation and buyer s only remedy shall be the replacement and or repair by the manufacturer of the product as described above NEITHER SELLER NOR THE MANUFACTURER SHALL BE LIABLE FOR ANY INJURY LOSS OR DAMAGE DIRECT INCIDENTAL OR CONSEQUENTIAL INCLUDING BUT NOT LIMITED TO INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR LOST PROFITS LOST SALES INJURY TO PERSON OR PROPERTY OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL LOSS ARISING OUT OF THE USE OR THE INABILITY TO USE THE PRODUCT AND THE USER AGREES THAT NO OTHER REMEDY SHALL BE AVAILABLE TO IT Bef
22. ATE OR SERVICE YOUR PRODUCT KNOW THE PRODUCT S APPLICATION LIMITATIONS AND POTENTIAL HAZARDS PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE DESCRIPTION This unit is designed to pump wastewater from laundry trays washing machines sinks or dehumidifiers It is not designed to pump raw sewage fluids other than water or fluids with solids Inlet screen will remove many solids over 1 8 diameter but large amounts of solids can clog screen and result in pump failure Maximum fluid temperature is 125 F Unit is designed to fit under most sinks so in many cases it is not necessary to recess the unit into the floor ITEMS TO PURCHASE NOTE Some state or local codes require all electrical and or plumbing connections to be made by a licensed contractor It is the customer s responsibility to determine codes involved and to comply with these codes If user can install unit items to purchase are 1 Inlet piping with trap and union Basin cover has 1 1 2 FNPT fitting 2 Discharge piping with swing check valve and union Basin cover has 1 1 2 FNPT fitting 3 Vent piping Basin cover has 2 FNPT fitting SAFETY GUIDELINES E 1 CAUTION To reduce the risk of electric shock pull plug before servicing this pump 2 Read all instructions and safety guidelines thoroughly Failure to follow the gui
23. CI N para reducir el riesgo de choque el ctrico desconecte la unidad de la toma de corriente antes de brindar servicio a esta bomba Lea todo el instructivo el no seguir estas recomendaciones puede causar serios da os a la persona y al equipo Consulte los c digos el ctrico y de construcci n locales antes de la instalaci n La instalaci n deber hacerse de acuerdo con sus reglamentaciones Durante el funcionamiento normal la bomba de sumidero est inmersa en agua Adem s durante las tormentas puede haber agua en el rea circundante de la bomba Se debe observar precauci n para prevenir lesiones personales al trabajar cerca de la bomba Desconecte el cord n de alimentaci n el ctrica antes de tocar brindar mantenimiento o reparar la bomba Para disminuir el riesgo de choques el ctricos posiblemente fatales tenga sumo cuidado al cambiar los fusibles No pise agua mientras cambia los fusibles ni introduzca el dedo en el recept culo del fusible No haga funcionar la bomba en un sumidero seco Si hace funcionar a la bomba en un sumidero seco la temperatura de la superficie de la bomba acender hasta niveles elevados Estos niveles elevados podr an causar quemaduras de la piel si se toca la bomba y adem s causar n da os graves a su bomba No engrase el motor La caja de la bomba est sellada Desde la f brica se ha colocado un aceite diel ctrico de alto grado y repelente al agua dentro de la carcasa del motor El
24. ESPONSABILITE REPOSE LES DOMMAGES COMME ENONCES DANS CE PARAGRAPHE DOIVENT ETRE RAISONNABLEMENT ATTENUES DANS LA MESURE DU POSSIBLE CE PARAGRAPHE S APPLIQUERA EGALEMENT A TOUS LES DOMMAGES RESULTANT DES CONDITIONS ENONCEES DANS LA SECTION III CI DESSUS ET 1 AUX DEFAUTS DANS LES PROTOTYPES DE PRODUIT OU LES PROTOTYPES DE PIECE DE RECHANGE QUI N ONT PAS ETE MIS EN PRODUCTION DISTRIBUES ET VENDUS PAR LA SOCIETE ET OU 2 AUX DEFAUTS QUI N ONT PAS T TROUV S AU MOMENT DE LA VENTE POUR DES RAISONS SCIENTIFIQUES ET TECHNOLOGIQUES Cette Garantie Limit e vous donne des droits l gaux sp cifiques Vous pouvez avoir d autres droits qui varient selon les lois et r glements applicables Si toute stipulation de cette garantie est interdite par ces lois elle sera nulle et sans effet mais le reste de la pr sente garantie demeurera en vigueur AVIS DE NON RESPONSABILITE Les d clarations orales concemant le produit effectu e par le vendeur la Soci t les repr sentants ou toutes autres parties ne constituent pas une garantie L utilisateur ne doit pas sy fier et elles ne font pas partie du contrat de vente La seule obligation du vendeur et de la Soci t et l unique recours de l acheteur est le remplacement et ou la r paration du produit par la Soci t selon les modalit s d crites pr c demment Avant l utilisation l utilisateur doit d terminer l aptitude du produit pour son utilisation pr vue et l utilisateur assume tous les risques
25. Little GIANT Franklin Electric Co Inc Oklahoma City OK 1 800 701 7894 Fax 1 405 228 1561 www LittleGiantPump com customerservice lgpc com This instruction sheet will provide you with information required to safely own and operate your Little Giant WRSC 6 kit This unit is designed to pump wastewater from laundry trays washing machines sinks or dehumidifiers It is not designed to pump raw sewage fluids other than water or fluids with solids The inlet screen will remove many solids over 1 8 diameter but large amounts of solids can clog screen and result in pump failure Maximum fluid temperature is 125 F Unit is designed to fit under most sinks so in many cases it is not necessary to recess the unit into the floor WRSC 6 This instruction sheet covers the standard models in this pump series This form is applicable to other models in this series not listed by catalog number in the replacement parts list section of this pamphlet If the catalog number of your pump is not listed in the replacement parts section then exercise caution when ordering replacement parts Always give the catalog number of your pump when ordering replacement parts The Little Giant unit you have purchased is of the highest quality workmanship and material It has been engineered to give you long and reliable service Little Giant pumps are carefully packaged inspected and tested to ensure safe operation and delivery When you receive your pump
26. N EL PER ODO DE TIEMPO ESTABLECIDOS ANTERIORMENTE CONSTITUIR EL CUMPLIMIENTO DE TODA LA RESPONSABILIDAD DE LA COMPA A CON EL COMPRADOR YA SEA BASADO EN EL CONTRATO NEGLIGENCIA O DE OTRO MODO LA COMPAN A NO SER RESPONSABLE POR LOS DA OS ACCIDENTALES CONSEQUENTES O ESPECIALES TALES COMO PERO NO LIMITADOS A DA OS A O P RDIDA DE OTRA PROPIEDAD O EQUIPO P RDIDAS DE USO DEL EQUIPO PRESTACI N O SERVICIO P RDIDA DE GANANCIA O VENTAS COSTO DE COMPRAS O REMPLAZO DE BIENES RECLAMOS DE CLIENTES DEL COMPRADOR FALLA PARA ADVERTIR Y O INSTRUIR P RDIDA DE OTROS PRODUCTOS COSTOS DE REMEDIACI N AMBIENTAL O DISMINUCI N EN EL VALOR DE LA PROPIEDAD LOS RECURSOS DEL COMPRADOR AQU ESTABLECIDOS SON EXCLUSIVOS Y LA RESPONSABILIDAD DE LA COMPA A NO DEBE COMO EXPRESAMENTE CONSTAN AQU EXCEDER EL PRECIO DEL PRODUCTO EN EL QUE DICHA RESPONSABILIDAD SE BASA LOS DA OS QUE SE ESTABLECEN EN ESTE P RRAFO SER N RAZONABLEMENTE MITIGADOS HASTA DONDE SEA POSIBLE ESTE P RRAFO DEBE TAMBIEN APLICARSE A TODOS LOS DA OS QUE RESULTEN DE LAS CONDICIONES ESTABLECIDAS ANTERIORMENTE EN LA SECCI N III Y 1 DEFECTOS EN PROTOTIPOS DE PRODUCTOS O PROTOTIPOS DE PIEZAS DE RESPUESTO QUE NO HAYAN SIDO PRODUCIDAS PUESTAS EN CIRCULACI N O VENDIDAS POR LA COMPA A Y O 2 DEFECTOS QUE NO FUERON ENCONTRADOS AL MOMENTO DE LA VENTA DEBIDO A RAZONES CIENT FICAS O TECNOL GICAS Esta Garant a Limitada le otorga derechos legales espec ficos Tambi n pueden exi
27. PERO SIN LIMITARSE A DA OS INCIDENTALES O CONSECUENTES DEBIDO A GANANCIAS PERDIDAS VENTAS PERDIDAS DA OS A PERSONAS O PROPIEDADES O CUALQUIER OTRA PERDIDA INCIDENTAL O CONSECUENTE QUE RESULTE DEL USO O DE LA IMPOSIBILIDAD DEL USO DEL PRODUCTO Y EL COMPRADOR ACUERDA QUE NO EXISTE OTRO REMEDIO DISPONIBLE PARA EL Antes de usar el usuario debe determinar si el producto se adapta al uso deseado y el usuario asume todos los riesgos y responsabilidades en relaci n a ello Algunos estados y pa ses no permiten limitaciones sobre la duraci n de una garant a impl cita o la exclusi n o limitaci n de da os incidentales o consecuentes de manera que las limitaciones o exclusiones anteriores podr an no tener aplicaci n en su caso Esta garant a le da derechos legales espec ficos y usted podr a disponer tambi n de otros derechos que var an de un estado a otro y de un pa s a otro El C digo El ctrico Nacional en los Estados Unidos y c digos similares en otros pa ses requieren un Interruptor de circuito de falla de conexi n a tierra GFCI para ser instalado en el circuito secundario que suministra equipo de fuente calibrado por encima de 15 voltios En el almac n se encuentran GFCI de 115 voltios con varias longitudes de cable y recomendamos que cada bomba sea usada con un GFCI For parts or repair please contact For technical assistance please contact Pour des parties ou la r paration entrez s il vous pla t en co
28. RAIT DU COUVERCLE DU BO TIER DU MOTEUR DE LA TURBINE OU DES JOINTS ANNULE LA GARANTIE TOUTE R PARATION DU MOTEUR DOIT TRE EFFECTU E UN CENTRE DE SERVICE AUTORIS LITTLE GIANT 10 Assurez vous que le cordon d alimentation est en bon tat et ne pr sente ni entaille ni coupure GO ESPA OL Esta hoja de instrucciones le proporcionar la informaci n requerida para que pueda ser propietario de y poner en funcionamiento con seguridad las WRSC 6 Little Giant Esta unidad est dise ada para bombear aguas residuales de bandejas de lavander a lavadoras lavaplatos o deshumidificadores La unidad no est dise ada para bombear aguas residuales no tratadas fluidos que no sean agua o fluidos con s lidos La rejilla de la toma eliminar muchos s lidos con un di metro de m s de 1 8 pero grandes cantidades de s lidos pueden obstruir la rejilla y causar la falla de la bomba La temperatura m xima del fluido es 125 F La unidad est dise ada para instalarse bajo la mayor a de los lavaplatos de manera que en muchos casos no es necesario empotrar la unidad en el piso Esta hoja de instrucciones cubre los modelos est ndar en esa serie de bombas Este formulario es aplicable a otros modelos en esta serie que no aparecen listados por n mero de cat logo en la secci n de piezas de repuesto de este folleto Si el n mero de cat logo de su bomba no est listado en esa secci n de piezas de repuesto se debe entonces tomar pr
29. RTURE PR CIS E CI DEVANT La pr sente garantie sera ANNUL E si 1 Le bo tier scell du moteur a t ouvert 2 Le branchement une tension autre que celle indiqu e sur la plaque du fabricant a t effectu 3 Le fil d alimentation a t coup une longueur inf rieure 0 91 m trois pieds 4 La pompe a tourn a vide l alimentation en liquide a t coup e 5 La pompe a t utilis e pour faire circuler des liquides autres que de l eau fra che des huiles l g res ou d autres liquides non corrosifs et ce la temp rature ambiante 6 La pompe a t mal utilis e Toute d claration sur la pompe faite oralement par le vendeur le fabricant le repr sentant ou par toute autre partie ne constitue pas une garantie et par cons quent ne peut servir l utilisateur De plus une telle d claration ne peut en aucun cas faire partie du contrat de vente L unique obligation du vendeur et du fabricant et unique recours de l acheteur est le remplacement ou la r paration de la pompe selon les modalit s d crites pr c demment NI LE VENDEUR NI LE FABRICANT NE PEUVENT TRE TENUS RESPONSABLES DE TOUTE BLESSURE TOUTE PERTE OU TOUT DOMMAGE DIRECT INDIRECT OU ACCESSOIRE INCLUANT MAIS NON EXCLUSIVEMENT LES VENTES OU PROFITS PERDUS LES ATTEINTES AUX PERSONNES OU LA PROPRI T OU TOUTE AUTRE PERTE INDIRECTE OU ACCESSOIRE R SULTANT DE L UTILISATION OU DE L INCAPACIT D UTILISATION DE LA POMPE
30. TOR HOUSING COVER IMPELLER OR SEALS HAVE BEEN REMOVED ANY REPAIR ON MOTOR MUST BE DONE BY AN AUTHORIZED LITTLE GIANT SERVICE CENTER 10 Be certain power cord is in good condition with no nicks or cuts Figure 1 PLATE ALIGNMENT DIAGRAM DIAGRAMME DE L ALIGNEMENT DE LA PLAQUE DIAGRAMA DE ALINEACION DE LA PLACA G FRANCAIS Cette liste de directives vous fournit les renseignements n cessaires pour utiliser une WRSC 6 Little Giant en toute s curit Cette pompe est con ue pour pomper les eaux us es des bacs a linge sale des machines a laver des viers ou des d shumidificateurs Elle n est pas congue pour pomper des eaux d gout des liquides autres que de l eau ou des liquides comportant des solides L cran d entr e retiendra beaucoup de particules d passant 1 8 po de diam tre toutefois une grande quantit de mati res solides peut bloquer l cran et causer une panne de la pompe La temp rature du liquide ne doit pas d passer 125 F La pompe est con ue pour aller sous la majorit des viers il est donc dans la plupart des cas inutile de l encastrer dans le plancher La pr sente feuille d instructions d crit les mod les standard de cette s rie de pompe Ce document s applique galement d autres mod les de cette s rie qui ne sont pas indiqu s par leur num ro de catalogue dans la section des pi ces de remplacement du pr sent document Si tel tait le cas avec votre pompe il faudra tre particuli
31. UIER OTRA GARANTIA EXPRESA CUALQUIER 7 GARANTIA IMPLICADA INCLUYENDO PERO NO LIMITADO A CUALQUIER GARANTIA IMPLICADA DE COMERCIALIZACION O APTITUD PARA PROPOSITO PARTICULAR EN LA MEDIDA EN QUE SE PUEDA APLICAR A UNA BOMBA QUEDARA LIMITADA EN DURACION A LOS PERIODOS DE GARANTIAS PROPORCIONADOS ANTERIORMENTE La garant a ser declarada NULA si se encuentran cualesquiera de las siguientes condiciones 1 El alojamiento sellado del motor abierto 2 El producto conectado a un voltaje que no es el indicado en la placa principal 3 El cable cortado a menos de tres pies 0 91 m 4 Se permiti que la bomba opere en seco env o de fluido cortado 5 La bomba empleada para hacer circular cualquier otra sustancia que no sea agua fresca aceites livianos u otros l quidos livianos aproximadamente a temperatura ambiente 6 Abuso del producto por parte del cliente Cualquier declaraci n oral acerca del producto hecha por el vendedor fabricante representantes o cualquiera de las partes no constituyen garant as el usuario no debe confiarse de ellas y no forman parte del contrato de compra venta La nica obligaci n del vendedor y del fabricante y el nico remedio para el comprador ser la reposici n y o reparaci n del producto por parte del fabricante bajo las condiciones descritas anteriormente NI EL VENDEDOR NI EL FABRICANTE SE HACEN RESPONSABLES DE NINGUNA LESION PERDIDA O DA O DIRECTO INCIDENTAL O CONSECUENTE INCLUYENDO
32. Usure de la roue aubes due Replace worn impeller Remplacer la roue aubes us e aux abrasifs Desgaste de la rueda m vil debido a abrasivos Cambie la rueda m vil gastada Pump cycles continually La pompe recommence son No check valve in long discharge pipe allowing liquid to drain Install a check valve in discharge line Installer une soupape cycle sans s arr ter La bomba se enciende y apagalback into sump Absence de soupape d arr t dans le grand d arr t sur le tuyau d coulement Instale una v lvula de continuamente tuyau d coulement ainsi permettant l coulement du liquide retenci n en la tuber a de descarga dans le puisard de r ception Falta la v lvula de retenci n en el tubo de descarga largo lo cual permite que el l quido refluya a la sumidero Check valve leaking Fuite la soupape d arr t e Escape en Inspect check valve for correct operation V rifier la soupape la v lvula de retenci n d arr t pour obtenir un bon fonctionnement Verifique que la v lvula de retenci n funcione correctamente Sump pit too small for inflow Le puisard est trop petit pour Install larger sump pit Installer un puisard plus grand l affluence El sumidero es muy peque o para el flujo que entra Provea un pozo de sumidero m s grande LIMITED WARRANTY Your Little Giant product is guaranteed to be in perfect condition when it leaves our factory lt is warranted against defective materials
33. aci n descuido alteraci n accidente abuso modificaci n actos de Dios rayos incluidos actos de terrorismo actos de guerra incendios almacenamiento e instalaci n inadecuados uso inadecuado mantenimiento o reparaci n inadecuados da o o siniestro en exceso de las m ximas recomendadas que se establecen en las instrucciones del producto Cualquier producto que sea operado con cualquier accesorio equipo componente o pieza que no est espec ficamente aprobada por la Compa a El uso de piezas de repuesto que no sean vendidas por la Compa a la adici n no autorizada de productos que no sean de la Compa a a productos de la Compa a y la alteraci n no autorizada de productos de la Compa a Los productos da ados por el desgaste normal mantenimiento normal y las piezas utilizadas en conexi n con dicho servicio o cualquier otras condiciones m s all del control de la Compa a Cualquier producto que haya sido utilizado para otros prop sitos m s all de aquellos para los cuales fue dise ado y fabricado Cualquier uso del producto en el cual las instrucciones de instalaci n y o las instrucciones para el uso no hayan sido seguidas Productos conectados a otro voltaje que el indicado en la placa de identificaci n Productos en los cuales la bomba fue expuesta a cualquiera de los siguientes arena grava cemento grasa yeso barro brea hidrocarburos derivados de los hidrocarburos aceite gasolina solventes
34. ad Ub quela de forma tal que la toma de entrada est alimentada por gravedad La unidad no extraer agua desde un nivel m s bajo Coloque y nivele el dep sito Mant ngalo alejado de cualquier art culo que pueda perforarlo La posici n seleccionada debe ser conveniente para las tuber as de entrada descarga del respiradero y alimentaci n el ctrica Instale la tuber a de entrada Usar el adaptador de descarga apropiado al mecanismo de sujeci n de la tapa del dep sito Utilice un sif n tipo P y una uni n a continuaci n del dep sito Use un compuesto de unir tuber as y apriete a mano solamente los accesorios pl sticos No disminuya el tama o de la tuber a por debajo de 1 1 2 Se provee un adaptador liso de 1 1 2 MNPT x 2 si se requiere entrada de 2 Consulte Instalaci n t pica Instale la tuber a de descarga Usar el adaptador de descarga apropiado al mecanismo de sujeci n de la tapa del dep sito Use una v lvula de retenci n m vil a no m s de 3 de la tapa del dep sito y la uni n Aseg rese que la v lvula de retenci n est instalada en la direcci n correcta del fluido Si sta se instala contrariamente no correr agua hacia afuera de la unidad Aseg rese que la tuber a de la descarga est sellada con un compuesto de unir tuber as y que la altura de elevaci n de la bomba no se excede Apriete a mano solamente los accesorios pl sticos Se provee un adaptador liso de 1 1 2 MNPT x 2 si se requie
35. al times to clear air from pump If system includes a check valve a 3 16 hole should be drilled in discharge pipe approximately 2 above discharge connections Couper le courant pendant 1 minute environ puis recommencer R p ter cette op ration plusieurs fois pour vacuer l air de la pompe If system includes a check valve a 3 16 hole should be drilled in discharge pipe approximately 2 above discharge connections Desconecte la electricidad durante un minuto aproximadamente Luego vu lvala a conectar Repita varias veces para purgar el aire de la bomba Si el sistema tiene un v lvula de retenci n debe perforarse un orificio de ventilaci n en el tubo de descarga aproximadamente 2 pulgadas por encima de las conexiones de descarga Liquid inflow matches pump capacity Afflux de liquide correspondant au volume de la pompe El caudal que entra es igual a la capacidad de la bomba Defective switch Commutateur d fectueux Interruptor defectuoso Larger pump required Une pompe plus puissante est n cessaire Se requiere una bomba mayor Disconnect switch check w ohmmeter Open infinitive resistance closed zero D brancher le commutateur v rifier avec un ohmm tre Ouvert r sistance infinitive ferm z ro Desconecte el interruptor e inspecci nelo con el ohm metro abierto resistencia infinita cerrado cero Loose connection in level control wiring e Connexion des fils lectriques du ni
36. alling the basin cover Any other position will prevent assembly of cover Placer la plaque de l alignement l int rieur du r servoir tel qu illustr Ainsi les trous de montage seront correctement align s au moment de la pose du couvercle du r servoir Tout autre positionnement de la plaque ne permettra pas la pose du couvercle Coloque la placa de alineacion dentro del dep sito como se ilustra Esto permitir la alineaci n apropiada de los agujeros de montaje cuando instale la cubierta del dep sito Cualquier otra posici n no permitir armar la cubierta Ensure mounting hole 1 lines up with locating rib 2 on inside of basin Le trou de montage 1 s aligne avec une nervure 2 de positionnement situ e l int rieur du r servoir Los agujeros de montaje 1 se alinean con un saliente de ubicaci n 2 dentro del dep sito DIRECTIVES DE S CURIT a A AVERTISEMENTA Votre pompe demandera tr s peu d entretien Si pour une raison quelconque elle ne peut pas fonctionner suivez les instructions ci dessous Ne pas utiliser pour pomper des liquides explosifs ou inflammables essence huile k ros ne etc No se use en ambientes explosivos o lugares epligrosos segun la clasificacion del Codigo Electrico Nacional NEC y la norma NFPA7O Del Instituto Nacional Norteamericano De Normas Utiliser avec des liquides compatibles avec les mat riaux de la pompe Ne pas manipuler la pompe les mains humid
37. anical vent will cause improper operation of the auto matic switch 5 Test unit Connect power cord to electrical supply as stated in ELECTRICAL CONNECTIONS section Secure power cord to piping with ties or tape Fill unit with water through inlet Pump should turn on with 7 10 of water in tank and turn off when 1 3 of water is left in tank MAINTENANCE WARNING Before performing any maintenance shut off water inlet and disconnect power cord from supply outlet Pump may become hot during operation Allow pump to cool before servicing Basin Screen Remove 4 1 4 20 screen cover plate screws plastic cover plate seal ring and screen Clean inlet screen using a mild detergent and water Examine O ring and if deformed replace with new O ring See replacement parts table Basin Sediment may build up in basin causing pump to oper ate improperly Remove 10 1 4 20 screws from cover Remove cord grommet and loosen cords to allow slack and then remove cover Remove pump and clean basin using a mild detergent and water Reassemble in reverse order Torque screws 18 20 in lbs If pump alignment plate is removed it must be reinstalled per pump alignment diagram Figure 1 Typical Installation CORD GROMMET INCLUDED 2 VENT PIPE FILTER ACCESS COVER WITH O RING FILTER al mn COLES i N ll e UNION 1 1 2 INTAKE COVER O RING LITTLE GIANT PUMP MODEL 6 CIA _
38. ant une distance ne d passant pas 8 cm 3 po du couvercle du r servoir et d un raccord union S assurer que le clapet est install dans le bon sens s il est install l envers l eau ne pourra pas tre refoul e par la pompe S assurer aussi que la conduite de sortie est scell e avec de la p te joints et que la hauteur statique de refoulement de la pompe n a pas t d pass e Ne serrer les raccords de plastique qu la main A 1 1 2 MNPT x 2 Un adaptateur de tube par glissement est fourni si un refoulement de 2 est requis 4 Faire le raccordement du tuyau d a ration l aide de la carte appropri e plumb d charge raccord de couverture du bassin Utiliser de la p te joints sur les filets et ne serrer les raccords de plastique qu la main Le r servoir doit tre a r conform ment aux normes nationales et provinciales A 2 MNPT x 1 1 2 Un adaptateur de tube par glissement est fourni si un vent de 1 1 2 est requis CET APPAREIL NE FONCTIONNERA PAS SANS UNE A RATION AD QUATE MISE EN GARDE Ne pas utiliser d a ration m canique avec ce produit un tel dispositif causerait un mauvais fonctionnement de l interrupteur automatique 5 Tester la pompe Brancher le cordon d alimentation une fiche lectrique comme cela est indiqu la section Branchements lectriques Fixer le cordon d alimentation au tuyau avec des attaches ou du ruban adh sif Remplir le r servoir d eau par l entr e La
39. antPump com CustomerService WTS fele com Form 993167 01 2012 Rev 001 2012 Franklin Electric Co Inc Little Giant is a registered trademark of Franklin Electric Co Inc Litie GIANT BiG jonne Franklin Electric Co Inc SU BM ERSI BLE o 57 2010 PUMP Eo o 6 CIA CustomerService WTS fele com 4 INTRODUCTION This instruction sheet provides you with the information required to safely own and operate your product Retain these instructions for future reference The product you have purchased is of the highest quality workmanship and material and has been engineered to give you long and reliable service This product has been carefully tested inspected and packaged to ensure safe delivery and operation Please examine your item s carefully to ensure that no damage occurred during shipment If damage has occurred please contact the place of purchase They will assist you in replacement or repair if required READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL OPERATE OR SERVICE YOUR PRODUCT KNOW THE PRODUCT S APPLICATION LIMITATIONS AND POTENTIAL HAZARDS PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE SAFETY GUIDELINES WARNING To reduce the risk of electrical shock remove the plug from the outlet before servicing this pump Read all instructions and safety guidelines thoroughly Fa
40. ate the warranty period of this product will begin to run on the product s date of manufacture Il INSTRUCTIONS APPLICABLE TO THIS LIMITED WARRANTY 1 Consumers wishing to submit a warranty claim must return the products accompanied by this warranty to the point of purchase for warranty consideration 2 Upon discovery of a defect any personal injury property damage or any other type of resulting damage if applicable shall be reasonably mitigated to the extent possible 3 At its discretion the Company may inspect products either at its facilities or in the field and after determination of a warranty claim will at its option repair or replace defective parts Repaired or replaced parts will be returned freight prepaid by the Company 4 This warranty policy does not cover any labor or shipping charges The Company shall not be liable for any costs or charges attributable to any product testing maintenance installation repair or removal or for any tools supplies or equipment needed to install repair or remove any product Ill LIMITATIONS APPLICABLE TO THIS LIMITED WARRANTY THIS WARRANTY DOES NOT APPLY TO ANY OF THE FOLLOWING 1 Brushes impeller or cam on models with brush type motors and or flex vane impellers 2 Any product that is not installed applied maintained and used in accordance with the Company s published instructions applicable codes applicable ordinances and or with generally accepted industry standards
41. autorizado por Little Giant Esta unidad se encuentra lubricada permanentemente No se requiere lubricaci n Jam s en ning n caso abra la parte de la unidad que est sellada o retire los tornillos de la caja Quite los tornillos art culo 4 que sostienen la base de la voluta y limpie el impulsor y el pasaje de la voluta No use solventes fuertes en el impulsor Aseg rese de que el impulsor gire libremente antes de limpiarlo ADVERTENCIA NO QUITE EL IMPULSOR PARA QUITAR EL IMPULSOR SE REQUIEREN HERRAMIENTAS ESPECIALES Y ESTO DEBE HACERSE SOLO EN UN CENTRO DE SERVICIO AUTORIZADO Cuando instale de nuevo la base aseg rese que el anillo de sellado est apropiadamente asentado en la ranura y apriete los tornillos con una torsi n de 12 a 17 cm Kg NO QUITE LA CUBIERTA DE LA CAJA DEL MOTOR LA GARANTIA ES NULA SI SE QUITA LA CUBIERTA DE LA CAJA DEL MOTOR EL IMPULSOR O LOS OBTURADORES CUALQUIER REPARACION DEL MOTOR DEBE HACERSE EN UN CENTRO DE SERVICIO AUTORIZADO DE LITTLE GIANT Aseg rese de que el cable de potencia est en buenas condiciones y que no tenga cortes o rasgaduras TROUBLESHOOTING INFORMATION INFORMATION SUR LA REL VE DES D RANGEMENTS INFORMACION DE INVESTIGACION DE AVERIAS PROBLEM FONCTIONNEMENT DEFECTEUX PROBLEMA Pump will not shut off Note Before trouble shooting automatic control check to see that pump operates on manual control To do this create slight vacuum on breather tube near plug
42. cia de esta garant a se basar en la fecha de manufactura m s dos a os Cualquier producto que falle por alguna de las dos razones anteriores y que est dentro del per odo de garant a ser reparado o reemplazado a opci n de Proven y ste ser el nico remedio del comprador Para nuestros clientes en los ESTADOS UNIDOS CONTINENTALES Por favor devolver la unidad defectuosa con el porte pagado a la f brica en 301 North MacArthur Blvd Oklahoma City OK 73127 6616 Todo producto defectuoso devuelto bajo la garant a ser cuidadosamente inspeccionado para determinar la causa de la falla antes de aprobar la garant a Para nuestros clientes ubicados en otros lugares no es econ mico devolver la bomba a la f brica para que sta sea inspeccionada debido a los impuestos y al flete Por favor devuelva la unidad defectuosa a cualquier distribuidor o vendedor autorizado con una breve explicaci n por escrito del problema Si no existen se as aparentes de abuso por parte del cliente la unidad ser reemplazada o reparada Si se produce una disputa sobre el reemplazo de la bomba el distribuidor o vendedor debe separar los art culos y retenerlos para que sean inspeccionados por un representante de Little Giant o avisarle a la f brica de los detalles del problema para que la f brica disponga de las acciones necesarias y resuelva el reclamo de la garant a DESAUTORIZACION LA GARANTIA ANTERIOR ES UNA GARANTIA EXCLUSIVA EN LUGAR DE CUALQ
43. ctada Pump is air locked Pr sence d une poche d air dans la pompe La bomba est llena de burbujas de aire Lift too high for pump Aspiration trop puissante pour la pompe Altura de impulsi n excesiva para la bomba Low voltage speed too slow Voltage et vitesse pas assez puissants Voltaje demasiado bajo velocidad demasiado baja Impeller or discharge pipe is clogged Obstruction de la roue aubes ou du tuyau d coulement La rueda m vil en el tubo de descarga est oclu da Impeller wear due to abrasives Usure de la roue aubes due aux abrasifs Desgaste de la rueda m vil debido a abrasivos CORRECTIVE ACTIONS SOLUTIONS SOLUCION Replace switch e Remplacer le commutateur Cambie el interruptor Replace rubber diaphragm Remplacer le caoutchouc du diaphragme Cambie el diafragma de caucho Clear vent tube of any obstructions Nettoyer le tuyau de purge Despeje el tubo de aspiraci n de cualquier obstrucci n Clean area around rubber diaphragm Nettoyer le contour de caoutchouc du dia phragme Limpie el rea que rodea el diafragme de caucho Shut power off for approximately 1 minute then restart Repeat several times to clear air from pump If system includes a check valve a 3 16 hole should be drilled in dis charge pipe approximately 2 above discharge connections Couper le courant pen dant 1 minute environ puis recommencer R p ter cette op ration plus
44. ded All fixtures connected to the WRS 6 Basin Kit must be vented according to state and local codes 1 Determine proper location for unit Locate unit so that inlet is gravity fed Unit will not draw water up from a lower level Position and level basin Keep basin away from any item that could puncture basin Position selected should be convenient to inlet discharge and vent piping and electrical supply 2 Plumb inlet Using 1 1 2 threaded pipe plumb inlet to basin cover fitting Use a P trap and a union next to the basin Use pipe joint compound and hand tighten only on plastic fittings Do not reduce below 1 1 2 piping 3 Plumb discharge Using 1 1 2 threaded pipe plumb discharge to basin cover fitting Use a swing check valve no more than 3 from top of basin cover and a union Be sure check valve is installed in proper flow direction If check valve is installed backwards no water will flow out of unit Be sure discharge piping is sealed with pipe joint compound and that lift height of pump is not exceeded Hand tighten only on plastic fittings 4 Plumb vent Plumb vent using 2 threaded pipe to fitting in basin cover Use pipe joint compound on threads and hand tighten only on plastic fittings The basin must be vented in accordance with state and local codes The vent is essential for proper switch operation and must not be omitted or restricted CAUTION Do not use a mechanical vent with this product A mech
45. delines and the instructions could result in serious bodily injury and or property damage 3 Check local electrical and building codes before installation The installation must be in accordance with these regulations 4 During normal operation the pump is immersed in water Use caution to prevent bodily injury when working near the pump a Remove plug from the receptacle prior to touching servic ing or repairing the pump b To minimize possible fatal electrical shock hazard use extreme care when changing fuses Do not stand in water while changing fuses or insert your finger into fuse socket ELECTRICAL CONNECTIONS All wiring must meet local codes and a licensed electrical contractor is recommended The pump is supplied with a 3 prong vented plug Plugs must be plugged into a grounded receptacle and vent tube must remain unobstructed for proper pump operation Pump should be on a separate circuit with fuse or circuit breaker and ground fault circuit interrupter GFCI Be sure electrical supply matches pump nameplate data Do not use extension cord If installed in basement plug connection should be 4 or more above floor especially if basement floods Be sure electrical connections cannot be reached by rising water Under no circumstances should outlet box or receptacle be located where it may become flooded or submerged by water INSTALLATION All plumbing must meet local codes A licensed plumbing con tractor is recommen
46. durante el ensamblado de la unidad y al completar la instalacion El no hacerlo asi puede causar la ruptura de la tuberia el fallo de la bomba el fallo de los cojinetes del motor etc El motor de la bomba est equipado con un protector t rmico de reposici n autom tica y puede reposicionarse inesperadamente El accionamiento del protector es una indicaci n de sobrecarga del motor debida a un voltaje demasiado alto o bajo un cableado inadecuado conexiones de motor incorrectas o un motor o bomba defectuosos Si la bomba es una bomba llena de aceite la caja del motor viene de f brica llena de un lubricante diel ctrico para proporcionar una termotransferencia ptima del motor y una lubricaci n permanente de los cojinetes El uso de cualquier otro lubricante podr a causar aver as y anular la garant a Este lubricante no es t xico no obstante si escapa de la caja del motor puede quitarse r pidamente de la superficie del agua colocando sobre ella toallas de papel u otro material absorbente para embeberlo con el fin de no perturbar la vida acu tica CONEXIONES ELECTRICAS Consulte el r tulo de la bomba para conocer el voltaje adecuado que se requiere No la conecte a un voltaje distinto del indicado Si la bomba est dotada de un enchufe el ctrico de tres dientes el tercer diente es para ponerla a tierra con el fin de prevenir el peligro de posibles choques el ctricos NO QUITE el tercer diente del enchufe Se recomienda
47. e a la tuber a de descarga Esto proteger al cable contra da os y evitar que la bomba sea sacada del sumidero por su cable de alimentaci n de corriente 6 La instalacion correcta del tapon es con el tubo de aspiracion hacia abajo Figure 1 7 PRUEBE LA BOMBA DESPUES DE HABER HECHO TODAS LAS CONEXIONES Haga correr agua en el sumidero No trate de hacer funcionar la bomba sin agua esto da ar los obturadores y los cojinetes y podr a producir una aver a permanente a la bomba Llene el sumidero al nivel normal de funcionamiento y permita que la bomba saque el agua hasta alcanzar el nivel normal de detenci n Rem tase a la figura 2 8 Coloque la tapa sobre el sumidero Esta tapa evitar que los residuos s lidos llenen el fondo evitar los olores y proteger contra las lesiones accidentales REPLACEMENT PARTS vn fan Description Qty 1 108101 Handle pump 1 2 928004 Seal ring 1 3 108029 Pump base air bleed blue 1 4 909021 Screw washer 10 24 x 1 2 5 5 108082 Screen intake 1 6 928028 Seal ring 1 7 108049 Housing assembly automatic 8 1 8 108202 Bracket switch 1 9 951961 Lead wire assembly 1 10 924001 O ring 2 11 950323 Switch miniature 1 12 599026 AD 6 reducer adaptor 1 13 902404 Screw tap 8 18 x 3 8 1 14 108125 Diaphragm 1 15 108055 Co
48. e les deux autres bleu ou blanc sont sous tension LIRE ATTENTIVEMENT LE MODE D EMPLOI AVANT LE MONTAGE OU LE DEMONTAGE DE LA POMPE LITTLE GIANT V rifiez la r glementation locale en mati re d lectricit et de b timent avant de proc der l installation L installation doit respecter cette r glementation ainsi que le Code national de l lectricit le plus r cent S assurer que le tuyau de ventilation est dirig vers le bas et raccorder une prise mise la terre Pour que la pompe fonctionne bien le tuyau ne doit pas tre obstru Si la pompe est install e dans un sous sol la connexion lectrique doit se faire au moins quatre pieds du niveau du sol particuli rement si le sous sol risque d tre inond S assurer que l eau ne peut atteindre le niveau des connexions Le bo tier ou la prise de courant ne devrait jamais se trouver endroit o il pourrait tre submerg TYPICAL INSTALLATION INSTALLATION TYPE e L z S INSTALACION TIPICA Power cord Cordon de secteur Cable el ctrico Cr OQ Check valve la Clapet anti retour V lvula de Retenci n B i
49. e water surface to soak it up so aquatic life is undisturbed WARNING RISK OF ELECTRIC SHOCK This pump is supplied with a grounding conductor and grounding type attachment plug To reduce the risk of electric shock be certain that it is connected only to a properly grounded grounding type receptacle ELECTRICAL CONNECTIONS This pump is supplied with a 3 prong electrical plug The third prong is to ground the pump to prevent possible electric shock hazard Do not remove the third prong from the plug A separate branch electrical circuit is recommended Do not use an extension cord INSTALLATION 1 Clean any debris from sump pit and set pump in center of pit A solid bottom will prevent clogging of the pump from sand and dirt 2 Connect discharge piping and run it to the nearest sewer or surface outlet Use pipe joint compound at all connections These pumps can be piped to discharge into the house drainage system to a dry well splash block or to a storm drain depending on local plumbing codes The discharge pipe should be as short as possible and contain as few elbows as possible The discharge pipe should be the same diameter as the discharge size to reduce pipe friction losses Smaller pipe will restrict capacity and reduce pump performance This pump comes with 11 2 female thread discharge and 11 FNPT reducing bushing 3 Always install a union in the discharge line just above the sump pit to allow for easy remova
50. ecauciones cuando se hace el pedido de piezas de repuesto Cuando pida piezas de repuesto d siempre el n mero de cat logo de su bomba La unidad Little Giant que usted ha adquirido posee la m s alta calidad de fabricaci n y materiales Ha sido dise ada para brindarle una larga vida de servicio sin problemas Las bombas Little Giant se envasan cuidadosamente registradas y probadas para asegurar la entrega y operaci n segura Cuando usted recibe su bomba examina lo cuidadosamente para determinar que no hay roto o da ado partes que pueden haber ocurrido durante el embarque Si el da o ha ocurrido hecho anotaci n y notificado la firma que usted compr la bomba desde Ellos ayudar n usted en el reemplazo o la reparaci n si requiri LEA DETENIDAMENTE LAS INSTRUCCIONES ANTES DE INTENTAR INSTALAR OPERAR O DAR MANTENIMIENTO A LA BOMBA LITTLE GIANT CONOZCA LAS LIMITACIONES APLICACIONES Y LOS PELIGROS POTENCIALES DE LA BOMBA PROTEJASE A SI MISMO Y A LOS DEMAS CUMPLIENDO TODAS LAS RECOMENDACIONES DE SEGURIDAD EL INCUMPLIMIENTO DE LAS INSTRUCCIONES PODRIA RESULTAR EN LESIONES PERSONALES Y O DA OS MATERIALES CONSERVE LAS INSTRUCCIONES PARA REFERENCIAS FUTURAS REGLAMENTO DE SEGURIDAD Gh M ADVERTENCIA 1 Asegurese de que la unidad este desconectada de la fuenta de alimentacion electrica antes de intentar prestar servicio a la unidad o quitar cualquier componente de ella 2 No use la unidad para bombear liquido
51. een O Ring Buna N 2 339 Cover plate screen Alignment plate O Ring Buna N 2 131 Figure 3 En MOUNTING HOLE LINES UP_WITH LOCATING RIB ON THE INSIDE OF THE BASIN PLATE ALIGNMENT DIAGRAM POSITION THE PUMP LOCATING PLATE INSIDE THE BASIN AS SHOWN THIS WILL ALLOW PROPER ALIGNMENT OF MOUNTING HOLES WHEN INSTALLING THE BASIN COVER ANY OTHER POSITION WILL NOT ALLOW ASSEMBLY OF COVER SPECIFICATIONS MODEL No VoLTS HERTZ watts 5 157 SHUTOFF CFT le 15 9 Oo o n 78 WRS 6 115 2750 1750 7 8 FOR TROUBLESHOOTING INFORMATION SEE PUMP OWNERS MANUAL INCLUDED WITH WRS 6 BASIN KIT ONE YEAR LIMITED WARRANTY For one year from date of purchase Little Giant will repair this unit if defective in material or workmanship Warranty service is available by returning the unit pre paid to the factory For further details please consult the warranty statement on carton This warranty gives you specific legal rights and you may also have other rights which vary from state to state For parts or repair please contact 1 888 572 9933 For technical assistance please contact 1 888 956 0000 Pour des parties ou la r paration entrez s il vous pla t en contact 1 888 572 9933 Pour l aide technique entrez s il vous plait en contact 1 888 956 0000 Para partes o la reparaci n por favor p ngase en contacto
52. emperature 12 Products in which the pump was allowed to operate dry fluid supply cut off 13 Products in which the sealed motor housing has been opened or the product has been otherwise dismantled by customer 14 Products in which the cord has been cut to a length of less than three feet The Company reserves the right at any time and from time to time to make changes in the design and or improvements upon its product without thereby imposing any obligation upon itself to make corresponding changes or improvements in or upon its products already manufactured and or previously sold The Company further reserves the right to substitute parts or components of substantially equal quality in any warranty service required by operation of this Limited Warranty This written Limited Warranty is the entire warranty authorized and offered by the Company There are no warranties or representations beyond those expressed in this document THIS WARRANTY AND REMEDY IS IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND OR FITNESS FOR A PARTICULAR PURPOSE WHICH ARE HEREBY SPECIFICALLY DISCLAIMED AND EXPRESSLY EXCLUDED CORRECTION OF NON CONFORMITIES IN THE MANNER AND FOR THE PERIOD OF TIME AS SET FORTH ABOVE SHALL CONSTITUTE FULFILLMENT OF ALL LIABILITY OF THE COMPANY TO THE PURCHASER WHETHER BASED ON CONTRACT NEGLIGENCE OR OTHERWISE T THE COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL
53. es les pieds pos sur une surface mouill e ou humide ou les pieds dans l eau N utilisez pas le cordon d alimentation pour sortir la pompe de l eau alors que la pompe fonctionne ou qu elle est reli e une source d alimentation Votre pompe vient avec un fil de mise a la terre et ou une prise a trois branches Afin de r duire le rusque de choc lectrique s assurer que la pompe est branch e a une prise correctement mise a la terre Le Code national de l lectricit exige qu un interrupteur de mise la terre GFI soit install sur le circuit d installation d une fontaine d une piscine etc L utilisation d un ou de plusieurs syst mes auxiliaires et ou d un syst me d alarme est recommand e pour toute installation potentiellement dangereuse fuite ou d fectuosit caus es par une coupure de courant un blocage du circuit de refoulement ou pour toute autre raison pour les personnes ou la propri t Immobiliser la pompe et les tuyaux lors de l installation et de l utilisation afin d viter tout risque de dommages aux tuyaux la pompe aux roulements bille du moteur etc Le moteur de la pompe est pourvu d un dispositif de protection thermique d marrage automatique elle peut red marrer tout moment Le d clenchement du dispositif de protection indique une surchauffe du moteur provoqu e par un voltage excessif ou insuffisant un c blage non appropri des erreurs de raccordement du moteur une d fail
54. etc u otras sustancias abrasivas o corrosivas Productos en los cuales la bomba fue utilizada para bombear o circular otra cosa aparte de agua potable a temperatura ambiente Productos en los cuales la bomba fue habilitada para operar en seco sin suministros de fluidos Productos en los cuales la carcasa sellada del motor fue abierta o el producto fue de otro modo desmantelado por el cliente Productos en los cuales la longitud del cable fue cortada a una medida menor a 3 pies La Compa a se reserva el derecho de en cualquier momento y ocasionalmente introducir cambios en el dise o y o mejoras en sus productos sin que esto imponga ninguna obligaci n de introducir los cambios o mejoras correspondientes en los productos ya fabricados y o previamente vendidos La Compa a se reserva adem s el derecho de sustituir piezas o componentes de calidad equivalente en cualquier servicio de garant a requerido por operaci n de esta Garant a Limitada Esta Garant a Limitada escrita es la totalidad de la garant a autorizada y ofrecida por la Compa a No existen garant as y representaciones m s all de aquellas expresadas en este documento ESTA GARANT A Y RECURSO EST N POR ENCIMA DE TODAS LAS OTRAS GARANT AS Y RECURSOS QUE SE INCLUYEN SIN LIMITACI N GARANT AS DE MERCANTIBILIDAD Y O ADECUACI N PARA UNA FINALIDAD ESPEC FICA QUE SON AQU EXPL CITAMENTE NEGADAS Y EXPRESAMENTE EXCLU DAS LA CORRECI N DE DISCONFORMIDAD DE LA MANERA Y E
55. euves concr tes de la date d achat la p riode de garantie de ce produit commencera partir de la date de fabrication du produit Il INSTRUCTIONS APPLICABLES A CETTE GARANTIE LIMIT E 1 Les consommateurs qui souhaitent soumettre une r clamation de garantie doivent retourner les produits avec cette garantie au point de vente pour consid ration de garantie 2 En cas de d couverte d un d faut une l sion corporelle un dommage mat riel ou tout autre type de dommages en r sultant le cas ch ant doivent tre raisonnablement att nu s dans la mesure du possible 3 sa discr tion la Soci t peut inspecter les produits soit ses installations soit au site et apr s d termination d une r clamation de garantie sa discr tion fera r parer ou remplacer les pi ces d fectueuses Les pi ces r par es ou remplac es seront retourn es avec frais de transport pr pay s par la Soci t 4 Cette politique de garantie ne couvre pas les frais de main d oeuvre ou d exp dition La Soci t ne sera pas responsable des co ts ou des frais imputables tout essai entretien installation r paration ou enl vement de produit ou pour tout outil fourniture ou quipement n cessaire pour installer r parer ou enlever tout produit Il LIMITATIONS APPLICABLES CETTE GARANTIE LIMIT E CETTE GARANTIE NE S APPLIQUE PAS AUX SUIVANTS 1 Balais impulseur ou came sur des mod les avec des moteurs de type balais et ou des impulse
56. examine it carefully to determine that there are no broken or damaged parts that may have occurred during shipment If damage has occurred make notation and notify the firm where you purchased the pump They will assist you in replacement or repair if required READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL OPERATE OR SERVICE THE LITTLE GIANT PUMP KNOW THE PUMP APPLICATION LIMITATIONS AND POTENTIAL HAZARDS PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONALINJURY AND OR PROPERTY DAMAGE RETAIN INSTRUCTIONS FOR FUTURE REFERENCE SAFETY GUIDELINES 1 Make certain that the unit is disconnected from the power source before attempting to service or remove any component 2 Do not use to pump flammable or explosive fluids such as gasoline fuel oil kerosene etc Do not use in explosive atmospheres or hazardous locations as classified by NEC ANSI NFPA70 Pump should be used with liquids compatible with pump component materials 3 Do not handle the pump with wet hands or when standing on a wet or damp surface or in water 4 Do nat pull the pump out of the water by the power cord when the pump is operating or connected to power source 5 This pump is supplied with a grounding conductor and or grounding type attachment plug To reduce the risk of electrical shock be certain that it is connected to a properly grounded grounding type receptacle 6 T
57. he National Electric Code requires a ground fault circuit interrupter GFCI be installed in the branch circuit supplying fountain equipment pools etc 7 In any installations where property damage and or personal injury might result from an inoperative or leaking pump due to power outages discharge line blockage or any other reason a backup system s and or alarm should be used 8 Support pump and piping during assembly and when installed Failure to do so may cause piping to break pump to fail motor bearing failures etc The pump motor is equipped with an automatic resetting thermal protector and may restart unexpectedly Protector tripping is an indication of motor overloading as a result of excessively high or low voltage inadequate wiring incorrect motor connections or a defective motor or pump pump is an oil filled pump the motor housing is filled with a dielectric lubricant at the factory for optimum motor heat transfer and lifetime lubrication of the bearings Use of any other lubricant could cause damage and void the warranty This lubricant is non toxic however if it escapes the motor housing it should be removed from the surface quickly by placing newspapers or other absorbent material on the water surface to soak it up so aquatic life is undisturbed ELECTRICAL CONNECTIONS AWARNINGA Check the pump label for proper voltage required Do not connect to voltage other than that shown If pump is suppl
58. ied with a 3 prong electrical plug the third prong is to ground the pump to prevent possible electrical shock hazard DO NOT REMOVE the third prong from the plug A separate branch circuit is recommended Do not use an extension cord Do not cut plug from the cord If the plug is cut or the cord is shortened then this action will void the warranty If the cord is equipped with stripped lead wires such as on 230 V models be sure that the lead wires are connected to a power source correctly The green yellow wire is the ground The blue or white and the brown or black are live CONSULT INSTRUCTION SHEET ILLUSTRATIONS FOR PROPER ASSEMBLY AND DISASSEMBLY OF YOUR LITTLE GIANT PUMP Check local electrical and building codes before installation The installation must be in accordance with their regulations as well as the most recent National Electrical Code NEC Plug into a grounded receptacle with vent tube pointed down Vent tube must remain unobstructed for proper pump operation If installed in basement plug connection should be four feet or more above floor especially if basement floods Be sure electrical connections cannot be reached by rising water Under no circumstances should outlet box or receptacle be located where it may become flooded or submerged by water OPERATION Determine proper location for unit Unit should be located so that inlet is gravity fed Unit will not draw water up from a lower level Position and le
59. ieurs fois pour vacuer l air de la pompe S il y a une soupape d arr t percer un trou de 3 16 po dans letuyau d coulement environ 2 po au dessus des connexions d coulement Desconecte la electricidad durante un minuto aproximadamente Luego vu lvala a conectar Repita varias veces para purgar el aire de la bomba Si el sistema tiene un v lvula de retenci n debe perforarse un orificio de ventilaci n en el tubo de descarga aproximadamente 2 pulgadas por encima de las conexiones de descarga Larger pump required e Une pompe plus puissante est n cessaire Se requiere una bomba mayor Disconnect switch check w ohmmeter Open infinitive resistance closed zero D brancher le commutateur v rifier avec un ohmm tre Ouvert r sistance infinitive ferm z ro Desconecte el interruptor e inspecci nelo con el ohmimetro abierto resisten cia infinita cerrado cero Check control wiring V rifier le circuit lectrique Inspeccione los cables del regu lador Check flow indicating arrow on check valve body to insure it is installed properly V rifier la fl che indiquant l coulement pour s assurer que la soupape d arr t est bien mont e Inspeccione la flecha indicadora del flujo en el cuerpo de la v lvula de reten ci n para cerciorase de que se encuentre instalada correctamente Remove check valve and inspect for proper operation D monter et v rifier la soupape d arr t pour un bon fonctionneme
60. ilure to follow the guidelines and the instructions could result in serious injury and or property damage Check local electrical and building codes before installation The installation must be in accordance with their regulations During normal operation the pump is immersed in water Also during rain storms water may be present in the surrounding area of the pump Use caution to prevent bodily injury when working near the pump Remove the plug from the outlet before touching servicing or repairing the pump To minimize possible fatal electrical shock hazard use extreme care when changing fuses Do not stand in water while changing fuses or insert your finger into fuse socket Do not operate the pump in a dry basin This will cause the pump to become extremely hot causing burns if touched and or damage to the pump Do not oil the motor The pump housing is sealed A high grade dielectric oil devoid of water has been put into the motor housing at the factory Use of other oil could cause serious electric shock and or permanent damage to the pump This pump s motor housing is filled with a dielectric lubricant at the factory for optimum motor heat transfer and lifetime lubrication of the bearings Use of any other lubricant could cause damage and void the warranty This lubricant is non toxic however if it escapes the motor housing it should be removed from the surface quickly by placing newspapers or other absorbent material on th
61. l of the pump for cleaning or repair 4 In situations where the piping is long the vertical discharge is above 7 or 8 feet or a small pit has been provided use of a check valve is recommended to prevent backflow of water into the sump When a check valve is used drill a relief hole 1 8 or 3 16 diameter in the discharge pipe This hole should be located below the floor line between the pump discharge and the check valve Unless such a relief hole is provided the pump could air lock and will not pump water even though it will run 5 Tape pump and switch cords to discharge line with electrician s tape This will protect the cords from damage and will prevent power cords from interfering with float 6 Connect the power cord to an outlet vent tube down Figure 1 7 TEST THE PUMP AFTER ALL CONNECTIONS HAVE BEEN MADE Run water into sump Do not attempt to operate the pump without water this will damage the seals and bearings and could result in permanent damage to the pump Fill sump to normal ON level and allow pump to remove water to the normal OFF level Figure 2 8 Place cover over sump This cover will prevent solid debris from filling the pit prevent odors and guard against accidental injury INTRODUCTION Cette feuille d instructions vous fournit les informations n cessaires pour entretenir et faire fonctionner votre produit Conserver ces directives afin de pouvoir les consulter plus tard Le produit que vous
62. lance du moteur ou une d faillance de la pompe 10 Si la pompe est remplie d huile le carter est rempli d huile di lectrique servant de caloporteur pour la chaleur engendr e par le moteur et de lubrifiant pour les paliers L emploi d un autre lubrifiant quel qu il soit pourrait endommager l appareil et annuler la garantie Bien que cette huile ne soit pas toxique en cas de fuite enlever rapidement l aide de journaux pos s rapidement la surface de l eau pour que la vie aquatique ne soit pas perturb e CONNEXIONS LECTRIQUES A AVERTISSEMENTA Consulter l tiquette de la pompe pour conna tre la tension appropri e Ne pas raccorder une source autre que la tension sp cif e Si la pompe est quip e d une fiche d aiimentation lectrique trois broches la troisi me est destin e raccorder la pompe la terre pour liminer les risques d lectrocution NE PAS ENLEVER cette troisi me broche du cordon d alimentation Un circuit de branche s par est recommand Ne pas utiliser un prolongateur Ne pas couper la fiche du cordon Couper la fiche ou raccourcir le cordon entraineral annulation de la garantie Si le cordon est muni de conducteurs codes l aide de rayures comme pour les mod les en 230 volts s assurer que ces fils sont correctement raccord s la source d alimentation lectrique Ainsi le fil vert jaune est pr vu pour le retour la terre alors qu
63. n 22 6 em Intake Prise Toma Cover O Ring ann nt Couvercle avec joints toriques CL La ecipiente Cubierta O Ring 7 A LO16 Pump Pompe Bomba f Items not included with WRSC 6 basin kit 10 63 DIA Articles non inclus avec WRSC 6 bassin agna M2 E Art culos no incluidos con WRSC 6 recipiente 27 cm 14 50 DIA 36 8 cm Figure 2 FONCTIONNEMENT 1 Installer la pompe un endroit ad quat Elle devrait tre plac e de mani re ce que l entr e soit aliment e par gravit car elle ne peut aspirer l eau se trouvant un niveau inf rieur Installer le r servoir et le mettre de niveau loigner du r servoir tout objet qui pourrait le perforer L emplacement choisi pour la pompe doit convenir l entr e et la sortie aux tuyaux d a ration et aux fils lectriques 2 Faire le raccordement de l entr e l aide de la carte appropri e plumb d charge raccord de couverture du bassin Utiliser un siphon en P et un raccord union proximit du r servoir Utiliser de la p te joints et ne serrer les raccords de plastique qu la main Ne pas utiliser des tuyaux dont le diam tre est inf rieur 1 Y po A 1 1 2 MNPT x 2 Un adaptateur de tube par glissement est fourni si une entr e de 2 est requise Voir Installation typique 3 Faire le raccordement de la sortie l aide de la carte appropri e plumb d charge raccord de couverture du bassin Utiliser un clapet de non retour batt
64. n b ton coul typique fuera del nivel Fondo tipico de concreto colado en sitio Power Cord Taped to Pipe Fil d alimentation coll au tuyau avec un ruban Cord n el ctrico sujeto a la tuber a con cinta adhesiva Figure 2 Typical Installation INTRODUCCI N Esta hoja de instrucciones le proporciona la informaci n requerida para tener y operar de forma segura su producto Guarde las instrucciones para referencia futura El producto que ha adquirido se fabrica utilizando mano de obra y materiales de la m s alta calidad y ha sido dise ado para prestarle un servicio duradero y confiable Los productos son cuidadosamente probados inspeccionados y empacados para garantizarle una entrega y operaci n seguras Examine su unidad cuidadosamente para asegurarse de que no haya ocurrido ning n da o durante el transporte Si se ha presentado alg n da o comun quese con el lugar de compra Deber n darle asistencia para obtener la reparaci n o reemplazo si se requiere LEA ESTAS INSTRUCCIONES CUIDADOSAMENTE ANTES DE INTENTAR INSTALAR HACER FUNCIONAR O PRESTAR SERVICIO T CNICO A SU PRODUCTO CONOZCA CU LES SON LAS APLICACIONES LIMITACIONES Y PELIGROS POTENCIALES DE LA UNIDAD PROTEJA A TERCEROS Y PROT JASE A USTED MISMO SIGUIENDO TODA LA INFORMACI N DE SEGURIDAD LA FALTA DE CUMPLIMIENTO DE ESTAS INSTRUCCIONES PUEDE PRODUCIR LESIONES PERSONALES Y O DA OS A LA PROPIEDAD REGLAMENTO DE SEGURIDAD AMADVERTENCIALA PRECAU
65. nt Quite la v lvula de retenci n y verifique que funcione debidamente Check rating table V rifier le tableau d valuation Estudie la tabla de capacidad Pull pump and clean Tirer la pompe pour la nettoyer Saque la bomba y limpiela See corrective action above Voir ci dessus la solution Rem tase a la soluci n anterior Check rated pump performance V rifier les caract ristiques techniques de la pompe e Verifique el rendimiento normal de la bomba Check for proper supply voltage to make certain it corresponds to nameplate voltage S assurer que le voltage correspond bien celui mentionn sur la plaque Verifique que el suministro de electricidad sea adecuado para cerciorarse de que corresponde al voltaje indicado en la placa del fabricante Pull pump and clean Check pipe for scale or corrosion Tirer la pompe pour la net toyer V rifier la pr sence de d p ts ou de corrosion dans les tuyaux Saque la bomba y l mpiela Inspeccione el tubo en busca de capas de xido o corrosi n Replace worn impeller Remplacer la roue aubes us e Cambie la rueda m vil gastada PLATE ALIGNMENT DIAGRAM 29 Mounting hole lines up with a locating rib on the inside of the basin Le trou de montage s aligne avec une nervure de positionnement situ e l int rieur du r servoir Los agujeros de montaje se alinean con un
66. ntact Pour l aide technique entrez s il vous pla t en contact Para partes o la reparaci n por favor p ngase en contacto Para la ayuda t cnica por favor p ngase en contacto A A 1 888 572 9933 o a 1 888 956 0000 a 1 888 572 9933 1 888 956 0000 alarde 1 888 572 9933 1 888 956 0000 www LittleGiantPump com CustomerService WTS fele com Form 993707 09 29 2009 2009 Franklin Electric Co Inc Little Giant is a registered trademark of Franklin Electric Co Inc Little GIANT WRS 6 Wastewater Removal System with 6 CIA Pump Franklin Electric Co Inc P O Box 12010 Oklahoma City OK 73157 2010 405 947 2511 Fax 405 947 8720 www LittleGiantPump com CustomerService WTS fele com INTRODUCTION This instruction sheet provides you with the information required to safely own and operate your product Retain these instructions for future reference The product you have purchased is of the highest quality work manship and material and has been engineered to give you long and reliable service This product has been carefully tested inspected and packaged to ensure safe delivery and operation Please examine your item s carefully to ensure that no damage occurred during shipment If damage has occurred please con tact the place of purchase They will assist you in replacement or repair if required READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL OPER
67. on Rejilla toma 6 028028 Seal ring Anneau d tanch it Anillo de estancamiento 1 Housing assemby automatic 8 115v Carter ensemble turbine 108051 Automatique 2 4 m 115 V Cubierta ensamblaje de impulsor autom tico Lead wire assembly Assemblage fils plumb s Conjunto de hilos 951961 conductores O ring Buna N 2 007 Joint torique Buna N 2 007 Junta t rica thai Buna N 2 007 Switch miniature Commutateur miniature Interruptor miniature Screw machine 10 24 x 1 4 Vis m canique 10 24 x 1 4 Tornillo para metales de 10 24 x 1 4 de pulgada Screw tap 8 18 x 3 8 Vis taraud e N 8 18 x 3 8 Tornillo rosca macho 8 18 x 3 8 de pulgada 108125 Diaphragm Diaphragme Diafragna Cover automatic switch housing Couvercle bo tier du contacteur 15 108055 a i 4 E e automatique Cubierta de la caja del interruptor autom tico 16 909027 Screw washer 10 24 x 1 3 4 Vis rondelle N 10 24 x 1 3 4 e Tornillo y arandela de 10 24 x 1 3 4 de pulgada Washer 10 lock Rondelle verrouillage 10 Arandela de seguridad 921023 10 O ring Buna N 2 131 Joint torique Buna N 2 131 Junta t rica Cover late screen Couvercle plaque grille Cubierta de placa rejilla Basin cover R servoir couvercle Dep sito cubierta Screw 1 4 20 x 1 2 Vis 1 4 20 x 1 2 Tornillo 1 4 20 x 1 2 Basin R servoir Dep sito Discharge pipe Refoulement tu
68. or esta garant a al punto de compra para consideraci n de la garant a Ante el descubrimiento de un defecto cualquier lesi n personal da o a la propiedad o cualquier otro tipo de da o que resulte si aplica ser razonablemente mitigado hasta donde sea posible A su criterio la Compa a puede inspeccionar los productos ya sea en sus instalaciones o en el rea y luego de la determinaci n del reclamo de garant a reparar o cambiar las piezas defectuosas a su criterio Las piezas que fueron reparadas o cambiadas ser n devueltas por medio de un flete prepago por parte de la Compa a Esta garant a no cubre ning n cargo por mano de obra o transporte La Compa a no se responsabilizar por ning n costo o cargo que est relacionado a cualquier prueba del producto su mantenimiento instalaci n reparaci n o remoci n o de cualquier herramienta suministro o equipo que sea necesario para instalar reparar o remover alg n producto 41 12 13 14 Ill LIMITACIONES APLICABLES A ESTA GARANT A LIMITADA ESTA GARANT A NO APLICA A NINGUNO DE LOS SIGUIENTES CASOS Cepillos turbina o leva en modelos con motor de cepillo y o turbinas con aleta flexible Cualquier producto que no se instale aplique mantenga y utilice seg n las instrucciones publicadas de la Compa a c digos aplicables ordenanzas aplicables y o est ndares industriales generalmente aceptados Cualquier producto que haya sufrido uso indebido mala aplic
69. ore using the user shall determine the suitability of the product for the intended use and user assumes all risk and liability whatsoever in connection therewith Some states and countries do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state and country to country The National Electric Code in the USA and similar codes in other countries require a Ground Fault Circuit Interrupter GFCI to be installed in the branch circuit supplying fountain equipment rated above 15 volts 115 volt GFCI s with various cord lengths are in stock and we recommend each pump be used with a GFCI PLN GARANTIE LIMITEE La pr sente garantit que votre pompe Little Giant est en parfaite condition sa sortie de lusine La pompe est garantie contre tout d faut de mat riau ou de fabrication pendant une p riode de 24 mois partir de la date d achat ou 30 mois partir de la date de fabrication selon le premier terme atteint Si aucune preuve acceptable de la date d achat originale la dur e de cette garantie sera de deux ans compter de la date de fabrication Tout produit encore garanti qui serait d fectueux pour l une des deux raisons sus mentionn es sera r par ou remplac la discr tion d
70. pompe doit se mettre en marche lorsque le niveau d eau dans le r servoir est de 10 18 cm 4 7 po et s arr ter lorsqu il est 3 8 cm 1 3 po Voir le Guide de d pannage de la pompe si des probl mes surviennent DIRECTIVES D ENTRETIEN A AVERTISSEMENTA VOTRE POMPE DEMANDERA TR S PEU D ENTRETIEN SI POUR UNE RAISON QUELCONQUE ELLE NE PEUT PAS FONCTIONNER SUIVEZ LES INSTRUCTIONS CI DESSOUS 1 Pour nettoyer le filtre d arriv e retirer les 4 vis du couvercle de la grille d entr e article 21 le couvercle article 19 anneau du joint article 28 et la grille d entr e article 27 Utiliser un d tergent doux et de l eau pour nettoyer la grille d entr e V rifier le joint torique s il est d form le remplacer Consulter la liste des pi ces de replacement 2 R servoir Des s diments peuvent s accumuler dans le r servoir et causer un mauvais fonctionnement de la pompe Enlever les 10 vis 1 4 20 du couvercle retirer le passe fil donner du jeu aux fils et retirer le couvercle Retirer la pompe et nettoyer le r servoir l aide d eau et d un d tergent doux R assembler Serrer les vis avec un couple de 21 23 cm kg 3 Si la plaque d alignement de la pompe a t enlev e elle doit tre r install e selon le diagramme d alignement de la pompe 4 Pompe Des s diments ou d autres d bris peuvent bloquer la pompe et causer son mauvais fonctionnement Si n cessaire retirer la pompe de l in
71. r cord to electrical supply as stated in ELECTRICAL CONNECTIONS Secure power cord to piping with ties or tape Fill unit with water through inlet Pump should turn on with 4 to 7 10 2 17 8 cm of water in tank and turn off when 11 2 to 31 2 3 8 cm of water is left in tank See Pump Troubleshooting Guide if problems occur SPECIFICATIONS CARACTERISTIQUES TECHNIQUES ESPECIFICACIONES Catalog No Amps Gallons per hour GPH at ht Shutoff FT Reference Amp res Litres par huere Hauteur Model No Catalogue Volts Hertz Amperios Watts Litros por hora d bit nul Mod le No Cataloga Volts Hertz Watts A V lvula PSI N de Modelo N mero Voltios Hertz s R Watts 5 10 15 Cerrda Kg cm2 WRSC 6 506065 115 60 13 9 720 2750 1750 750 18 7 8 WRSC 6 506066 230 50 T 5 720 2580 1050 12 5 2 SERVICE INSTRUCTIONS MAKE CERTAIN THE UNIT IS DISCONNECTED FROM THE POWER SOURCE BEFORE ATTEMPTING TO SERVICE OR REMOVE ANY COMPONENT 1 To clean inlet filter remove the 4 cover plate screws 21 cover plate 19 seal ring item 28 and screen item 27 Clean inlet screen using a mild detergent and water Examine o ring and if deformed replace with new o ring See replacement parts list 2 Sediment may build up in basin causing pump to operate improperly Remove 10 1 4 20 screws item 21 from cover Remove cord grommet and loosen cords to allow slack and then remove cover
72. re descarga de 2 Usar el adaptador de descarga apropiado al mecanismo de sujeci n de la tapa del dep sito Use un compuesto de unir tuber as en las roscas y apriete a mano solamente los accesorios pl sticos El dep sito debe estar ventilado en conformidad con los c digos estatales y locales Se provee un adaptador liso de 2 MNPT x 1 1 2 si se requiere ventilaci n de 1 1 2 ESTA UNIDAD NO OPERAR SIN UN RESPIRADERO ADECUADO CUIDADO No use un respiradero mec nico con este producto ya que producir un funcionamiento incorrecto del interruptor autom tico Pruebe la unidad Conecte el cord n el ctrico a la alimentaci n como se indica en Conexiones el ctricas ELECTRICAL CONNECTIONS Asegure el cord n el ctrico a la tuber a con ataduras o cinta adhesiva Llene la unidad con agua a trav s de la toma de entrada La bomba debe encenderse cuando hay de 4 a 7 de agua en el dep sito y apagarse cuando en ste queden de 1 1 2 a 3 1 2 de agua Ver a bomba Troubleshooting Guide si se producen problemas INSTRUCCIONES DE SERVICIO ASEGURESE DE QUE LA UNIDAD ESTE DESCONECTADA DE LA FUENTA DE ALIMENTACION ELECTRICA ANTES DE INTENTAR PRESTAR SERVICIO A LA UNIDAD O QUITAR CUALQUIER COMPONENTE DE ELLA f 10 Para limpiar el filtro de la toma de entrada quite los cuatro 4 tornillos de la cubierta de la cobertura tem 21 la cubierta de la cobertura item 19 anillo de cierre item 28 y la rejilla item 2
73. s inflamables ni explosivos tales como gasolina fueloil queroseno etc NO SE USE EN AMBIENTES EXPLOSIVOS O LUGARES EPLIGROSOS SEGUN LA CLASIFICACION DEL CODIGO ELECTRICO NACIONAL NEC Y LA NORMA NFPA7O DEL INSTITUTO NACIONAL NORTEAMERICANO DE NORMAS La bomba se debe usar con liquidos compatibles con los materiales de los componente de la bomba 3 No manipule la bomba con las manos mojadas ni mientras se encuentre en una superficie mojada o hu meda o entre el agua 4 No saque la bomba del agua tirando del cable de potencia cuando la bomba est en funcionamiento o cuando est conectada a la fuente de potencia 5 Esta bomba se suministra con un conductor a tierra y o un enchufe de conexion de tipo de conexion a tierra Para reducir el riesgo de descarga electrica asegurese de conectar la unidad a un receptaculo del tipo polarizado y adecuadamente conectado a tierra 10 El C digo El ctrico Nacional National Electric Code requiere la instalaci n de un interruptor de circuito por falla a tierra GFCI en el ramal del circuito que suministra la corriente a fuentes piscinas etc En cualquier instalacion donde puedan ocurrir da os materiales y o lesiones personales que resulten del funcionamiento inadecuado o de fugas en la bomba a causa de fallos en la alimentacion electrica bloqueo de la linea de la descarga o cualquier otra razon se debera usar uno o varios sistemas de respaldo y o alarmas Apoye la bomba y la tuberia
74. saliente de ubicaci n dentro del dep sito Position the pump locating plate inside the basin as shown This will allow proper alignment of mounting holes when installing the basin cover Any other position will not allow assembly of cover Placer la plaque l int rieur du r servoir tel qu illustr Ainsi les trous de montage seront correctement align s au moment de la pose du couvercle du r servoir Tout autre positionnement de la plaque ne permettra pas la pose du couvercle Coloque la bomba poniendo la placa dentro del dep sito como se ilustra Esto permitir la alineaci n apropiada de los agujeros de montaje A LO16 cuando instale la cubierta del dep sito Cualquier otra posici n no permitir armar la cubierta AUTOMATIC PUMP MODELS MODELES DE POMPES AUTOMATIQUES MODELOS DE BOMBA AUTOMATICA BLACK OR BROWN NOIR OU MARRON NEGRO O CAFE BLACK NOIR NEGRO WHITE OR BLUE BLANC OU BLEU BLANCO O AZUL 5 GREEN OR GREEN YELLOW VERT OU VERT ET JAUNE VERDE O VERDE AMARILLENTO REPLACEMENT PARTS LIST PART ITEM NO NO DESCRIPTION QTY 108101 Handle pump Poign e pompe Manivela bomba 928004 Seal ring Anneau d tanch it Anillo de estancamiento 1 Pump base manual blue Pompe manuel de base bleue Bomba manual de base azul Screw washer 10 24 x 1 2 Vis rondelle N 10 24 x 1 2 e Tornillo y arandela de 10 24 x 1 2 de pulgada Screen intake Filtre d admissi
75. stallation retirer l cran nettoyer l aide d un d tergent doux et r installer La base de plastique de la pompe peut aussi tre enlev e afin de nettoyer le contour de la turbine et l int rieur de la base Enlever les six vis de la base et nettoyer cette derni re avec un d tergent doux Ne pas retirer la turbine Au moment de la r installation de la base s assurer que l anneau d tanch it se trouve dans la rainure Resserrer les vis avec un couple de 12 17 cm kg Consulter le manuel de la pompe pour d autres renseignements Pour toute autre r paration exp dier la pompe un Centre de service autoris Little Giant 5 Cette unit est lubrifi e en permanence Il n est pas n cessaire de la graisser N ouvrez jamais la partie scell e de l unit et n enlevez jamais les vis du bo tier 6 Retirez les vis pi ce 4 qui relient la base la volute puis nettoyez la turbine et le passage de la volute N utilisez aucun solvant puissant sur la turbine 7 Veillez ce que la turbine tourne librement une fois le nettoyage termin AVERTISSEMENT LAISSEZ LA TURBINE EN PLACE LE RETRAIT DE LA TURBINE N CESSITE DES OUTILS SP CIAUX ET NE PEUT TRE EFFECTU QU UN CENTRE DE SERVICE AUTORIS 8 Au moment de la r installation de la base s assurer que l anneau d tanch it se trouve dans la rainure Resserrer les vis avec un couple de 12 17 cm kg 9 LAISSER LE COUVERCLE DU BO TIER DU MOTEUR EN PLACE LE RET
76. stir otros derechos que pueden variar seg n las leyes y regulaciones aplicables Cuando cualquiera de los t rminos de esta garant a est prohibido por dichas leyes deben considerarse nulos e inv lidos pero el resto de esta garant a continuar con plena vigencia y efecto DESCARGO DE RESPONSABILIDAD Cualquier declaraci n oral sobre el producto hecha por el vendedor la Compa a los representantes o cualquier otra parte no constituye garant as no deber ser considerada v lida por el usuario y no son parte del contrato de venta La nica obligaci n del vendedor y la Compa a y el nico recurso del comprador ser n el remplazo o la reparaci n del producto por parte de la Compa a como fue descripto anteriormente Antes de su uso el usuario deber determinar si el producto es adecuado para el uso que se le intenta dar y el usuario asume todo el riesgo y la responsabilidad cualesquiera que fueren en conexi n con el mismo For parts or repair please contact For technical assistance please contact 1 888 572 9933 1 888 956 0000 Pour des parties ou la r paration entrez s il vous pla t en contact 1 888 572 9933 Pour l aide technique entrez s il vous pla t en contact 1 888 956 0000 Para partes o la reparaci n por favor p ngase en contacto 1 888 572 9933 Para la ayuda t cnica por favor p ngase en contacto 1 888 956 0000 www LittleGi
77. t non toxique toutefois s il devait s en chapper du bo tier retirez le de la surface en pla ant du papier journal ou un autre mat riau absorbant la surface de l eau Ainsi l environnement aquatique ne sera pas affect CONNEXIONS LECTRIQUES li AAVERTISEMENTA La pompe est quip e d une prise lectrique trois broches Pour viter les risques d lectrocution la troisi me broche relie la pompe la terre Ne pas retirer la troisi me broche de la prise Un circuit de d rivation s par est recommand Ne pas utiliser de prolongateur INSTALLATION A 4 A AVERTISEMENTA 1 Nettoyer tous les d bris qui pourraient boucher le bassin de r ception et placer la pompe au centre Un font solide vitera obstruction le sable ou la poussi re 2 Conecter le tuyau d coulement et amener jusqu un gout ou une rigole Pour toutes les connexions utiliser un mat riau d tanch it Selon les r gles locales de plumberie le bassin de r ception peut tre reli au syst me d coulement de la maison un puits ass ch un stoppeur d arroseur o un gout Le tuyau d coulement doit tre le plus court et le moins coud possible Afin de r duire les risques de perte par friction son diam tre doit tre le m me que celui de coulement Un tuyau trop petit limitera tanch it et r duira le fonctionnement La pompe est quip e d coulement filetage tayau femelle de 1 po e
78. t pipe 2 MNPT d for bi if it vent q D CIDE pee Basin vent pipe 2 required for basin cover if present vent is 1 1 2 Use a 1 1 2 slip adapter Tuyau de refoulement Un vent de 2 est requis pour ce couvert de bassin Si votre Tuberia de descarga vent est de 1 1 2 utiliser un adaptater de 1 1 2 Se re aus para on de cien bag MNPT Union para la tapa del reipiente Si la ventilaci n es de 1 1 2 s lo un adaptador liso de 1 1 2 p k Raccord ni n p 1 2 sio x 2 MNPT adaptor is provided if 4 1 2 vent i required Not included cas d un event de 1 1 2 un adaptateur a glissement de 1 1 2 x 2 0 gt mae Ma S MNPT est fourni Articles no compris Incluye un adaptador liso de 1 1 2 x 2 MNPT para ventilaci n de 1 1 2 No incluido TE Caine a 2 slip X 1 1 2 MNPT adapter provided Use if required Cubierta de acceso al filtro con O Ring qe E a 2 7 i it MrT esol late luye u i x1 Inlet of basin is 1 1 2 FNPT Admission du bassin de 1 1 2 FNPT Discharge of basin 1 1 2 FNPT La entrada del recipiente es 1 1 2 FNPT Filter Refoulement du bassin de 1 1 2 FNPT 2 slip x 1 1 2 MNPT adapter provided Use if required Filt La descarga del recipients es 1 1 2 FNPT Un adaptateur glissement de 2 x 1 1 2 MNPT iltre est fourni Filtro Incluye un adaptador liso de 2 x 1 1 2 MNPT por si es requerido Basin cover ji Couvercle du bassin y Tapa del Recipiente Union Raccord fi a 8 90 SZ Uni n hi o
79. t raccord de r duction FMPT de 1 po 3 L installation d un raccord au tuyau d coulement juste au dessus du bassin de r ception permettra le d montage pour le nettoyage ou une r paration ventuelle 4 Afin d viter le refoulement vers le bassin de r ception l utilisation d une soupape d arr t est recommand e si le tuyau est trop long l coulement vertical est au dessus de 7 8 pieds ou si la fosse pr vue est petite Dans ce cas percer dans le tuyau d coulement un trou de d gagement d un diam tre de 1 8 po 3 16 po en dessous du sol entre l coulement de la pompe et la soupape d arr t pour viter qu un bouchon d air se produise qui emp cherait l appareil de pomper m me s il fonctionnait normalement 5 Fixer avec du ruban lectrique le fil d alimentation la conduite de sortie Ainsi le fil ne sera pas endommag et ne risquera pas de d placer la pompe 6 Le bouchon doit tre install avec le tuyau de vent en bas Figure 1 7 ESSAYER LA POMPE UNE FOIS TOUTES LES CONNEXIONS FAITES Laisser d eau au bassin de r ception Afin d viter une d t rioration d finitive de la pompe ou des joints d tanch it et des supports ne pas la faire fonctionner vide Remplir le bassin de r ception jusqu au niveau marqu On et laisser la pompe pomper jusqu au niveau normal marqu Off voir sch ma 2 8 Poser le couvercle sur le bassin de r ception Le couvercle vitera
80. t service de garantie exig par l ex cution de cette Garantie Limit e Cette Garantie Limit e crite est l enti re garantie autoris e et offerte par la Soci t Il n existe aucune garantie ou repr sentations autres que celles exprim es dans ce document CETTE GARANTIE ET CE RECOURS SONT EN LIEU ET PLACE DE TOUTES LES AUTRES GARANTIES ET RECOURS Y COMPRIS SANS S Y LIMITER AUX GARANTIES DE VALEUR MARCHANDE ET OU D ADAPTATION A UN USAGE PARTICULIER QUI SONT ICI SPECIFIQUEMENT REJETES ET EXPRESSEMENT EXCLUS LA CORRECTION DES NON CONFORMITES DE LA FACON ET POUR LA P RIODE DE TEMPS COMME ENONCEES CI DESSUS CONSTITUE LA REALISATION DE TOUTE LA RESPONSABILITE DE LA SOCIETE ENVERS L ACHETEUR QUE CELA SOIT SUR LA BASE D UN CONTRAT D UNE NEGLIGENCE OU AUTRE LA SOCIETE NE SERA PAS RESPONSABLE DES DOMMAGES DIRECTS INDIRECTS OU SP CIAUX COMME MAIS SANS SY LIMITER DOMMAGES A OU PERTES D AUTRES BIENS OU EQUIPEMENTS PERTE D UTILISATION D EQUIPEMENT INSTALLATIONS OU SERVICES PERTE DE B N FICES OU DE VENTES COUT D ACHATS OU DE PRODUITS DE RECHANGE RECLAMATIONS DES CLIENTS DE L ACHETEUR OMISSION D AVERTIR ET OU DE NOTIFIER PERTE D AUTRES PRODUITS OU COUTS D ASSAINISSEMENT DE L ENVIRONNEMENT OU DIMINUTION DE LA VALEUR DE LA PROPRIETE LE RECOURS DE L ACHETEUR ENONCE DANS LE PRESENT DOCUMENT EST EXCLUSIF ET LA RESPONSABILIT DE LA SOCIETE NE PEUT EXCEDER SAUF STIPULATION CONTRAIRE EXPRESSE LE PRIX DES PRODUITS SUR LESQUELS CETTE R
81. tchouc du diaphragme est faible ou durci Diafragma de caucho debilitado o endurecido Plugged vent tube Le tuyau de purge est branch e Tubos de aspiraci n ocluidos Dirt or sediment lodged between retainer ring and rubber diaphragm causing contacts to remain closed Boue ou r sidus log s entre le jonc et le caoutchouc du dia phragme emp chent les contacts de s ouvrir El sucio o sedimento atrapado entre el anillo de retenci n y el diafragma de caucho causa que los contactos permane zcan cerrados Pump is air locked Poche d air dans la pompe Burbujas de aire en la bomba Liquid inflow matches pump capacity Afflux de liquide correspondant au volume de la pompe El caudal que entra es igual a la capacidad de la bomba Defective switch Commutateur d fectueux Interruptor defectuoso Loose connection in level control wiring Connexion des fils lectriques du niveau de contr le distendue Conexiones flojas en los cables del regulador de nivel Check valve installed backwards Montage l envers de la soupape d arr t V lvula de retenci n montada al rev s Check valve stuck or plugged Soupape d arr t bloqu e ou obstru e V lvula de retenci n atorada u ocluida Lift too high for pump Aspiration trop puissante pour la pompe Altura de impulsi n excesiva para la bomba Inlet to impeller plugged Arriv e de la roue aubes obstru e Toma de la rueda m vil cone
82. u fabricant L acheteur maura pas d autre recours Pour nos clients aux TATS UNIS territoire continental seulement Veuillez retourner l article d fectueux suffisamment affranchi lusine l adresse suivante 301 North MacArthur Blvd Oklahoma City OK 73127 6616 Tous les produits garantis retourn s feront l objet d une inspection d taill e afin de d terminer si la d fectuosit est couverte par la garantie Pour les clients l ext rieur des tats Unis tant donn les frais de douane et de transport il n est pas conomique de retourner la pompe l usine pour inspection Exp dier la pompe ainsi qu une br ve description du probl me tout distributeur ou d taillant autoris Si elle ne pr sente aucun signe apparent d une mauvaise utilisation elle sera remplac e ou r par e S il y a conflit sur la n cessit de remplacer la pompe le distributeur ou le d taillant devra garder celle ci et soit la fera inspecter par un repr sentant de Little Giant soit avisera l usine du probl me afin de conna tre la d cision de celle ci et le r glement de la r clamation D N GATION LA GARANTIE NONC E DANS LES PR SENTES EST EXCLUSIVE ET REMPLACE TOUTE AUTRE GARANTIE EXPRESSE OU IMPLICITE CELA COMPORTE MAIS NON EXCLUSIVEMENT TOUTE GARANTIE IMPLICITE D APTITUDE LA COMMERCIALISATION OU D APTITUDE PARTICULI RE POUVANT S APPLIQUER UNE POMPE PROVEN DE PLUS ELLE NE S APPLIQUE QUE DURANT LA P RIODE DE COUVE
83. urs flex vane palette flex 2 Tout produit qui n est pas install appliqu entretenu et utilis conform ment aux instructions publi es par la Soci t aux codes et r glements applicables en vigueur et ou aux normes g n ralement accept es de l industrie 8 Tout produit qui a fait l objet d une utilisation anormale d une mauvaise application de n gligence d alt ration d accident d abus de modification d actes de Dieu y compris la foudre d actes de terrorisme d actes de guerre d incendie d un mauvais entreposage ou installation d une mauvaise utilisation d un mauvais entretien ou d une mauvaise r paration de dommages ou pertes ou d une utilisation au del des maximums recommand s comme nonc s dans les instructions du produit 4 Tout produit qui est utilis avec un accessoire mat riel composant ou pi ce non express ment agr s par la Soci t 5 L utilisation de pi ces de rechange non vendues par la Soci t l addition non autoris e de produits ne provenant pas de la Soci t d autres produits de la Soci t et la modification non autoris e des produits de la Soci t 6 Les produits endommag s par l usure normale les services habituels d entretien et les pi ces utilis es dans le cadre de ces services ou toute autre condition hors du contr le de la Soci t 7 Nimporte quel produit qui a t utilis des fins autres que celles pour lesquelles il a t con u et fabriqu
84. uso de otro tipo de aceite podr a causar da os el ctricos graves y o da os permanentes a la bomba La caja del motor de esta bomba ha sido llenada con un lubricante diel ctrico en la f brica para lograr una transterencia decalor ptima y la lubricaci n permanente de los cojinetes El uso de cualquier otro lubricante podr a causar da os y anular la garant a Este lubricante no es t xico sin embargo si se derrama de la caja del motor se debe recoger de la superficie r pidamente colocando peri dicos u otro material absorbente en la superficie del agua para limpiarlo a fin de no perturbar la vida acu tica CONEXIONES ELECTRICAS AMADVERTENCIALAA Su bomba est dotada de un enchufe el ctrico de tres dientes El tercer diente es para ponderla a tierra con el fin de evitar el riesgo de posibles choques el ctricos No quite el tercer diente del enchufe Se recomienda un circuito de ramal independiente No utilice cables de extensi n INSTALACION AlADVERTENCIAA 1 Limpie cualquier residuo del fondo del sumidero y coloque la bomba en el centro de ste Un fondo duro evitar que la bomba se obstruya con arena y tierra 2 Conecte la tuber a de descarga y ll vela a la alcantarilla o desague m s pr ximo Utilice el compuesto para empalmes de tubos en todos los empalmes Las bombas de sumidero pueden dotarse de tubos para que evac en en el sistema de drenaje de la casa en un dique seco un canal de desag e o
85. veau de contr le distendue Conexiones flojas en los cables del regulador de nivel Check control wiring V rifier le circuit lectrique e Inspeccione los cables del regulador Pump runs but does not discharge liquid e La pompelCheck valve installed backwards Montage l envers de la fonctionne mais il ny a pas d coulement de liquide La soupape d arr t V lvula de retenci n montada al rev s bomba funciona pero no descarga l quido Check flow indicating arrow on check valve body to insure it is installed properly V rifier la fl che indiquant l coulement pour s assurer que la soupape d arr t est bien mont e Inspeccione la flecha indicadora del flujo en el cuerpo de la v lvula de retenci n para cerciorase de que se encuentre instalada correctamente Check valve stuck or plugged Soupape d arr t bloqu e ou Remove check valve and inspect for proper operation obstru e V lvula de retenci n atorada u oclu da e D monter et v rifier la soupape d arr t pour un bon fonctionnement Quite la v lvula de retenci n y verifique que funcione debidamente Lift too high for pump Aspiration trop puissante pour la Check rating table V rifier le tableau d valuation Estudie pompe Altura de impulsi n excesiva para la bomba la tabla de capacidad Inlet to impeller plugged Arriv e de la roue aubes obstru e Pull pump and clean Tirer la pompe pour la nettoyer e e Toma de la rueda m
86. vel basin Keep basin away from any item that could puncture basin Position selected should be convenient to inlet discharge and vent piping and electrical supply Plumb inlet Using proper adapter plumb discharge to basin cover fitting Use a P trap and a union next to the basin Use pipe joint compound and hand tighten only on plastic fittings A 1 1 2 MNPT x 2 slip pipe adapter is provided if a 2 inlet is required See Typical Installation Plumb discharge Using proper adapter plumb discharge to basin cover fitting Use a swing check valve as close as possible to top of basin cover and union Be sure check valve is installed in proper flow direction If check valve is installed backwards no water will flow out of unit Be sure discharge piping is sealed with pipe joint compound and that lift height of pump is not exceeded Hand tighten only on plastic fitting A 1 1 2 MNPT x 2 slip pipe adapter is provided if a 2 discharge is required Plumb vent Plumb vent using 2 threaded pipe to fitting in basin cover Use pipe joint compound on threads and hand tighten only on plastic fittings The basin must be vented in accordance with state and local codes A 2 MNPT x 1 1 2 Slip pipe adapter is provided if a 1 1 2 vent is required THIS UNIT WILL NOT OPERATE WITHOUT PROPER VENTING CAUTION Do not use a mechanical vent with this product A mechanical vent will cause improper operation of the automatic switch Test Unit Connect powe
87. ver automatic switch housing 1 16 909027 Screw washer 10 24 x 1 3 4 4 17 921023 Washer 10 lock 1 18 901529 Screw machine 10 24 x 1 4 1 Q O BLACK OR BROWN BLACK 16 WHITE OR BLUE GREEN OR GREEN YELLOW Figure 3 Replacement Parts TROUBLESHOOTING INFORMATION INFORMATION SUR LA REL VE DES D RANGEMENTS INFORMACION DE INVESTIGACION DE AVERIAS PROBLEM FONCTIONNEMENT D FECTEUX PROBABLE CAUSES CAUSES PROBABLES CORRECTIVE ACTION SOLUTIONS PROBLEMA CAUSAS PROBABLES SOLUCION Pump will not shut off Note Before trouble shooting automatic Diaphragm switch C est le commutateur de diaphragme Replace switch Remplacer le commutateur Cambie el control check to see that pump operates on manual control Interruptor del diafragma interruptor To do this create slight vacuum on breather tube near plug then close off tube with thumb plug into wall outlet If pump Weak or hardened rubber diaphragm Le caoutchouc du Replace rubber diaphragm Remplacer le caoutchouc du works proceed to check switch if not fault is in pump or power diaphragme est faible ou durci Diafragma de caucho diaphragme Cambie el diafragma de caucho supply Le moteur de la pompe ne s arr te pas Remarque debilitado o endurecido avant de contr ler le fonctionnement automatique v rifier que 7 a q Plugged vent tube Le tuyau de purge est branch Tubos Clear vent tube of any obstructions Nettoyer le tuyau
88. yau Descarga tubo sid Pump 6 CIA ML 115 v Pompe 6 CIA ML 115 v Bomba 6 CIA ML 506161 ramp 6 CIA ML 230 v Pompe 6 CIA ML 230 v Bomba 6 CIA ML 925016 Cord grommet Passe fil Arandela aislante de cord n 113131 Intake screen D admission filtre Toma rejilla O ring Buna N 2 339 Joint torique Buna N 2 339 Junta t rica 77058 Buna N 2 339 Alignment plate See page 1 Plaque d alignement Montr sur la page 29 113135 a E ie 1 1 Plato de alineaci n Mostrado en la p gina 1 LIMITED WARRANTY THIS WARRANTY SETS FORTH THE COMPANY S SOLE OBLIGATION AND PURCHASER S EXCLUSIVE REMEDY FOR DEFECTIVE PRODUCT Franklin Electric Company Inc and its subsidiaries hereafter the Company warrants that the products accompanied by this warranty are free from defects in materials or workmanship of the Company that exist at the time of sale by the Company and which occur or exist within the applicable warranty period Any distributor sub distributor recipient end user and or consumer agrees that by accepting the receipt of the products the distributor sub distributor recipient end user and or consumer expressly agrees to be bound by the terms of the warranty set forth herein APPLICABLE WARRANTY PERIOD The products accompanied by this warranty shall be covered by this Limited Warranty for a period of 24 months from the date of original purchase by the consumer In the absence of suitable proof of purchase d
Download Pdf Manuals