Broan 103123 Instructions / Assembly

image

Contents

1. black to black white to white and green or bare wire to box with green ground screw provided Reinstall wiring box cover INSTALLER Leave this manual with the homeowner 5 Install ductwork Position the ductwork according to dimensions shown in appropriate illustration below Tape all joints MODEL 634 OR 644 ROOF CAP P MODEL 401 3 1 4 x 10 DUCT 3 3 8 MODEL 428 3 1 4 x 10 ELBOW MODEL 401 3 1 4 x 10 DUCT 3 3 8 HORIZONTAL DUCTING Broan NuTone LLC Hartford Wisconsin www broan com SERVICE PARTS Model 103123 Wood Hood Rough In Kit 6 KEY PART NO NUMBER DESCRIPTION 1 97007473 Rough In Plate 2 98003370 Wiring Box Cover 3 99150415 8B Sheet Metal Screw 4 99150471 10 32 x 1 2 Green Ground Screw 2 Required 5 99400052 Strain Relief Bushing 6 99440033 Power Cord 7 99150418 10AB x 1 Slotted Pan Head Sheet Metal Screw 4 Required Standard Hardware May be purchased locally WARRANTY BROAN ONE YEAR LIMITED WARRANTY Broan Mfg Co Inc warrants that its products will be free from defects in materials or workmanship for a period of one year from the date of original purchase During this one year period Broan will repair or replace at its option any product or part which is found to be defective under normal use and service without charge Broan s obligation to repair or replace at Broan s option shall be the purchaser
2. BROAN MODEL 103123 WOOD HOOD ROUGH IN KIT lt READ AND SAVE THESE INSTRUCTIONS WARNING Podati nr i SS TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent waming device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those Aite y the national Fite Protection Association NFPA and the n jeating igeration and Air Conditioning Engineers ASHRAE and the local codo authortes oiia k en cutting or drilling into wall or ceiling do not damage electrical wi other hidden utilities 9 g ee 6 Ducted fans must always be vented to the outdoors 7 To reduce the ris
3. k of fire use only metal ductwork 8 This unit must be grounded TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE Keep fan fitters and grease laden surfaces clean Always turn hood ON when cooking at high heat Use high range settings on range only when necessary Heat oii slowly on low to medium setting Don t leave range unattended when cooking Always use cookware and utensils appropriate for the type and amount of food being prepared oe opm The Wood Hood rough in kit consists of a plate with an electrical outlet box power cord and mounting hardware It locates the ductwork and electrical wiring for the hood It does not support the weight of the Wood Hood or Wood Hood Kit 1 Plan ducting Choose either VERTICAL or HORIZONTAL ducting for the hood Refer to the appropriate illustration WARNING ee E TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF ARANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then tum off the bumer BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be bumed 3 DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result 4 Use an extinguisher ONLY if A You know you havea Class ABC extinguisher and you already know how to operate it B The fire is small and contained in
4. o Inc Hartford Wisconsin 53027 Telephone 414 673 4340 or in California notify Broan Mfg Co Inc La Mirada California 90638 Telephone 213 926 0595 giving the model number part identification and nature of any defect in the product or part At the time of requesting warranty service evidence of the original purchase date must be presented Broan NuTone LLC_ Hartford Wisconsin www broan com 800 558 1711 800 558 1711 99040920F
5. s sole and exclusive remedy under this warranty THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES FILTERS DUCTS ROOF CAPS WALL CAPS AND OTHER ACCESSORIES FOR DUCTING This warranty does not include normal maintenance and service and does not apply to any products or parts which have been subject to misuse negligence accident improper maintenance or repair by others than Broan faulty installation or installation contrary to recommended installation instructions THERE IS NO OTHER EXPRESS WARRANTY BROAN HEREBY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT PERMITTED BY LAW The duration of any implied warranty which cannotbe disclaimed is limited to the one year period as specified in the express warranty Some states do not allow limitation on how long an Implied warranty lasts so the above limitation may not apply to you BROAN SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF ORIN CONNECTION WITH PRODUCT USE OR PERFORMANCE EXCEPT AS MAY OTHERWISE BE ACCORDED BY LAW Some states do not allow the exclusion of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties For service notify Broan Mfg C
6. the area where it started C The fire department is being called D You can fight the fire with your back to an exit Based on Kitchen Firesafety Tips published by NFPA CAUTION T For general ventilating use onty Do not use to exhaust hazardous or explosive materiais and vapors 2 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 3 This product is equipped with a thermostat which may start fan automatically To reduce the risk of injury switch power off at service panel and lock service panel to Prevent power from being switched on accidentally 4 Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated The motor will restart when it cools down If the motor continues to shut off and restart have the hood serviced 5 For best capture of cooking impurities your range hood should be mounted 18 24 above the cooking surface 6 Please read specification label on product for further information and requirements HORIZONTAL DUCTING 2 Add spacer Center rough in plate and space it away from framing with material the same thickness as drywall to be used 3 Mount plate 7 Fasten rough in plate securely to framing with four screws provided Follow dimensions shown 4 Connect wiring Run electrical wiring to installation location and fasten to wiring box Make electrical connections Connect