Home

Ella 93057 Use and Care Manual

image

Contents

1. Diverter N Rubber Gasket _ Tub 1 Shell _ _ os US C ai EE A B gt ci A EST OOO oOo II Rubber Wosher g AY Spout Water Line To Install the supplied spout first place the rubber gasket on the bottom of the spout and make sure it is properly seated in its groove Put the spout in through the hole in the tub shell shown in the drawing above Install the rubber washer and then the brass mounting nut Locate the water line from the spout diverter and connect if to the threading on the bottom of the spout Tighten all fittings and check for leaks NOTE Rubber gasket only comes with the Elite Royal and Petite models Spout must be tightened down prior to installation of tub WARNING Do not over tighten the water supply line To tighten properly it should be hand tight plus about a half a turn www ellasbubbles com Page 15 02 14 Installation of Deck Mount Grab Bar QI IC by ella s bubbles Parts List Chrome grab bar x 1 Escutcheon x 2 Rubber washers x 4 Metal washers x 2 Bolts x 2 Grab Bar HM yo Ce Rubber Tub Shell Washer Ce Ceo Rubber Ce Washer Seta Wosher cot To install the supplied grab bar first locate all the parts needed for installation See drawing shown above Ready the bolt assembly by first placing a metal washer onto the bolt followed by a rubber washer Feed the bolt up through the tub shell and place another rubber washer over the extruded bolt
2. Do not turn on the Hydro jets without water reaching the waterline The waterline is the point where all jets are covered with water DANGER Temperature in excess of 100 4 Fahrenheit 38 Celsius may be harmful to your health Check and adjust the temperature before use Consult your physician before using your Ella Walk in Bath if you have a heart condition or other health issues People using medications herbal remedies sleep aids and or having adverse medical history should consult a physician before using this product Pregnant women should NOT use this product before consulting their physician Avoid the use of alcohol drugs or other medications while using your walk in bath Be aware hyperthermia is a risk when raising body temperature Do no keep body submerged in heated bath for extended periods of time The symptoms of hyperthermia include an increase in body temperature which can cause dizziness lethargy drowsiness and fainting Avoid using the heated bath after strenuous activity Exercise caution while entering and exiting your Ella Walk in Bath www ellasbubbles com Page 3 02 14 Important Safety Instructions Continued QI IC by ella s bubbles WARNING To prevent stripping the PVC threads ONLY hand tighten the drain elbow DO NOT tighten with tools www ellasbubbles com Page 4 02 14 C IC Before Installation by ella s bubbles Protecting the Bath Cover and protect the bath shell and fixtures from
3. all four corners Finish the installation with baseboard VLMLV Panel On Panel Off Lowered Threshold Baseboard On not supplied NOTE Any alterations or installed additions are the responsibility of the installer Ella Accessible Bathrooms is not responsible for any damage to the unit or for water damage which could occur due to improper installation www ellasbubbles com Page 18 02 14 C Operating Instructions by ella s bubbles 1 Thermostatic Control Valve Before turning on the water please adjust the thermostatic control valve to the desired water temperature To raise the temperature above the preset 100 4 Fahrenheit press and hold in the button handle while turning For hotter water turn counterclockwise Conversely turn the valve clockwise for colder water The thermostatic control valve is pre set to 100 4 Fahrenheit for your safety Button Handle Round Knob O H x The button knob stops here at 100 4 Fahrenheit To adjust to a hotter temperature past 100 4 F press the button knob in while turning the handle counter clockwise 2 Using the Door Entering the walk in bath the door con be closed and locked with the handle from q seated or standing position Do not apply any body weight on the door when entering or exiting the walk in bath The door hinges are well built and are very durable however leaning on or applying weight on the door may damage and mis align the door and create leaks Such dam
4. followed by the escutcheon You may start the threading into the grab bar to hold the assembly loosely in position and then repeat the process for the second bolt Once the entire assembly is in place tighten the bolts with the suoplied Allen wrench WARNING Under no circumstances install the grab bar without the large metal washer underneath the tub shell Doing so will leave the tub shell vulnerable to cracking and void the warranty www ellasbubbles com Page 16 02 14 QI Installing Extension Kits by ella s bubbles Deluxe Dimensions 5 W x 29 1 2 L x 37 H L Stainless Steel Brackets Qty 3 Elite Dimensions 7 W x 29 3 4 L x 37 3 4 H L Acrylic Bracket Qty 1 Royal Dimensions 7 W x 31 3 4 L x 37 3 4 H VAVO Bolero Qty 7 Petite Dimensions 7 W x 27 2 4 L x 37 3 4 H RA riore OO N Qty 7 lv U I H Qty 1 NE Qty 9 0 29 Qty 7 Medium Woshers Qty 14 Small Wm gers Qty 14 Plastic Vg ger Qty 1 Plastic Capt QY 1 holes than mounting screws to allow for final adjustment to the panel mi 4 Mount extension with 7 P E Nu 1 Install 3 extension support brackets provide
5. that the door be kept open when not in use to increase the lifetime of the door seal and maintain its flexibility www ellasbubbles com Page 8 02 14 C IC Hydro Massage System Diagram by ella s bubbles Main Control Box SOUIJIMS IV Line Load N L1 N L1 N LT N LT Fuse Jewod OG l On Off Push Control 110v A C Circuit Breaker Panel 1 5 KW In Line Water Heater To Seat Area Out Hyrdro Jets 3 Da m Electrical Switch ee N d a A IE Return In EE ee saa CIHILA HTH Hydro Pump www ellasbubbles com Page 9 02 14 Air Massage System Diagram QI IC by ella s bubbles On Off Push Control Overflow Valve N To Air Jets NN N Air Tube AC Power from Main Control Box NOTE Make sure to keep airway splitter in highest position possible www ellasbubbles com Page 10 02 14 CI Q LED Chromatherapy System Diagram by ella s bubbles On Off Push Control LED Bulb Cluster Nylon Air Hose Ground SOUDJIMS JI Line Load N L1 N L1 N L1 N L1 J 1 JOMOd OG AT www ellasbubbles com Page 11 02 14 Ozone Generator System Diagram QI IC by ella s bubbles Hydro Massag
6. AA EE EE VER EE 15 installation BMS CK MOUNT Craba AN al 16 Installing Exter AA EE EE nennen nennt 17 ea ele siel OV EE EE ER EE OE EE EE EE OE 18 C Jio Ve EE m EE EE RE OE OE N 19 21 CIS SSS 1 s est mE mm 22 ACTOR l or piena ia 23 Valdaso A ge das EO EE OE EE DO ON 24 25 www ellasbubbles com 02 14 IC Unpack and Inspect by ella s bubbles NOTE Returns are only accepted in original packaging used for shipping Use caution so as not to damage cardboard crate or its wooden pallet Do not dispose of shipping material until installation is complete Please visit our website www ellasbubbles com for complete details of return exchange policy www ellasbubbles com Page 02 14 Move your Ella Walk in Bath C Q by ella s bubbles Remove all four 4 access panels before moving the tub eTake off the screw caps e Unscrew the screws with a Philips head screwdriver Remove the end access panel Large Access Panel 1 Small Access Panel 2 End Access Panel 4 White Screw Caps Toe Kick Access 3 Screw Washer Cap Access to parts Option to lower the Threshold WARNING Do not carry the walk in tub by the panels Be careful when carrying the tub avoid front panel contact with the floor or stairs to prevent damages Make sure no loose parts are hanging down Remove all four 4 access panels before carrying the tub to prevent them from falling out and breaking Slide
7. CIO by ella s bubbles 93057 L 93058 R 93057 LNF 93058 RNF 93107 L 93108 R Deluxe Dual Massage Deluxe Dual No Faucet Elite Dual Massage 93117 L 93118 R 93117 LNF 93118 RNF Massage Royal Dual No Faucet Royal Dual wer Jp Je 1 lt gt _ ui C71 Q Oo I I o O lt d Nam E I v ELLA MASSAGE WAL x Si 9 ED 4 O ve EET Et e 2 OWNER o Er aa P 9 o Y o o Oo na xs k up C IC Table of Contents by ella s bubbles Ugo de sed ike se AE EE OO E MOVE your Ella Walk in BOT CMT RE oe de ee Ge ee eo ee de De se os eg ke Ge wie ge ee GED 2 Important Safety SR e TT iis 3 4 Re lli qO el OO e m 5 Drain and Plumbing BW WERN Preparing IHERSUDSIIOOD sea eise et eee ha SSI IGS FEES did VERINdIGF E o o S E Sm 8 Koa s ie KEET EN bienni 8 Hydro Massage System Di mm ANA 9 Air Massage System Diagram Sb WSER A 10 LED Chromqotherqsgwsisssso DioorOga RN iii 11 Ozone Genefsyer System Diaci WNNR Leere nennen ne nnn rns 12 Ella Walk iggBath Electrical em Diagram SER W f W 13 eier OON ic AN TX 14 l O I E e M
8. NW G37 IOHUOD usnd HO UO by ella s bubbles CIO 02 14 Page 13 www ellasbubbles com Water Supply Lines QI Q by ella s bubbles Ella Dual Massage Walk in Baths with the Standard Ella Faucet Thermostatic Control Valve include two 4 ft long 1 2 P S connection flexible water supply lines Please note The 5 Piece Fast Fill Roman and 5 Piece Traditional Roman Fauce Sets do not include the I P S connection flexible water supply lines Pull Out Hand Shower Ozone ON OFF Air Flow Control Dial Thermostatic gt Control Valve Hand Shower w S Air Pump ON OFF Spout Diverter LED ON OFF Hydro Pump ON OFF 5 Hand Shower Pull Out Hose J 2 Z LED Fixture and Bulb A j bulb can be replaced from here Small Front Access Panel T 1e Cold Water Line 4 Long 1 2 Flexible Stainless b Steel Braided Hose with 1 2 NS a I P S Connector to Shut Off Valves AE Hot Water Line This side covered with end access panel for 2 wall installation option NOTE It is recommended that shut off valves are installed behind the opening and in reach from the small access panel www ellasbubbles com Page 14 02 14 IC Installation of Spout by ella s bubbles ALWAYS INSTALL SPOUT BEFORE THE WALK IN BATH IS IN PLACE Parts List Rubber gasket x 1 Rubber washer x 1 Brass mounting nut x 1 SPOUT Thermostatic Control Valve Spout Spout 7
9. On Brackets Deck Frame End Access Panel I gt eeeeubececeus Access Panel Screw On Support Brackets WARNING Lift and carry the tub only by the frame Protect the bottom of the tub to avoid breaking the air jets positioned on the bottom of the tub www ellasbubbles com Page 2 02 14 e C Important Safety Instructions by ella s bubbles WARNING Read through the entire manual completely before beginning installation Contract a licensed plumber and electrician for installation Be sure you and your contractor are aware and follow all local plumbing and electrical codes Your Ella Walk in Bath is not intended for outdoor use Install the tub in accordance with the instructions in the manual Use ONLY the parts and accessories provided or as recommended by the manufacturer CAUTION When using this product basic precautions should always be followed Read and follow all instructions pertaining to risk of fire electric shock and injury Make sure and have your licensed electrician test all connections to the dedicated line including the GFCI Risk of electric shock Do not permit electric appliances within 3 feet 1 5m of the tub i e hair dryers lamps phones radios televisions etc To reduce the risk of injury do not permit children or persons with disabilities to use this product unless they are supervised by an able bodied adult at all times Never drop or insert any objects into any openings
10. age to the pump or injury may OCCUF www ellasbubbles com DO NOT USE the following on your ACRYLIC Bath System The use of the following chemicals will cause a dull surface or chemical cracks The use of these products will VOID YOUR WARRANTY Any product containing ammonia Dow scrubbing bubbles Abrasive Cleaners Ajax Comet Fantistik Soft Scrub Mr Clean Nail Polish Remover Scouring Pads Ammonia Tough Act Powder or Crystal Drain Cleaners Greenworks Bathroom Cleaner Scrub Free w Bleach Seventh generation bathroom cleaner regular Magic Eraser Page 22 02 14 CIO by ella s bubbles Ella Acrylic Walk In Bath Warranty Information This limited lifetime warranty is extended to the first purchaser to be free from defects in workmanship and material under normal use and conditions from the date of the original purchase This warranty is nontransferable and applies only to the original owner and to the original installation place address only and does not extend to products previously used as display models or products that have been modified or repaired by anyone else but Ella s Bubbles The warranty is void if the ownership or original installation location is changed tub is relocated This warranty relates to all fittings and components included with the tub from the manufacturer The bathtub shell frame door seal and finish are covered by limited lifetime warranty The door is covered by a limited life
11. ages are not covered by the warranty 3 Using the Diverter Valves Close the door and fill up the bathtub with water by moving the faucet diverter handle in to the ON position The faucet and hand shower may be used individually or at the same time For both the faucet and the hand shower ON OFF 4 Using the Pull out Hand Held Shower To use the pullout hand held shower turn its diverter handle to the ON position The hand held shower is equipped with a 5 ft long retractable flex hose The pressure of the shower can be adjusted by turning the round shower head of the hand unit NOTE All Deluxe and Companion models have a protective lid Remove lid before using your hand held shower head WARNING Do NOT attach the hand held shower to the wall This may cause water to leak behind your walk in tub www ellasbubbles com Page 19 02 14 Operating Instructions Continued QI by ella s bubbles 5 Using the Hydro Massage To activate and deactivate the hydro massage pump push the on off the control button Page 9 There are two types of hydro jets in your walk in bath adjustable and non adjustable types Simply push on the head of an adjustable jet and turn the head in the desired position The in line water heater will activate with the Hydro pump An air flow rate control dial can be found over the shoulder of the seating area Turning the knob clockwise will reduce the amount of air introduced into the hydro system Adj
12. ate If the sub floor does not support the total weight of the bath bather and the water it can result in warping of the shell misalignment of the door and or create leaks and damages to the building structure www ellasbubbles com Page 7 02 14 Service Access and Ventilation QI IC by ella s bubbles It is the responsibility of the installer or owner to provide access for service required per code Ella is not responsible for any costs related to obtaining access for repair The owner shall assume responsibility for such costs and if appropriate must seek recovery from the installer Do not insulate around the tub equipment The tub frame and all parts have been engineered to provide the proper ventilation Any obstructions may cause the pumps or other electrical components to overheat Door Seal Please keep in mind that the door has been closed for an extended period of time throughout shipping and the bathtub has been stored in various temperatures It is possible for the silicone seal to stick to the frame when stored for extended periods of time When the bathtub is received the door seal should be checked for deformations from shipping and re formed and adjusted where necessary To restore the door seal the seal must be released and allowed to relax with the door open This is done by squeezing the seal with your finger tips and pulling it away from the door frame to regain its flexibility and original form It is recommended
13. be sent via certified mail to Ella s Bubbles LLC 2101 S Carpenter Street Chicago IL 60608 Email info ellasbubbles com The Manufacturer will not be responsible for any water damage to structures or property for any reason including but not limited to manufacturer defect or improper installation Manufacturer will assume no responsibility for the loss of the system inconvenience due to loss damage to real or personal property or any other consequential damage Manufacturer will not be liable for any incidental expenses or material charges in connection with removal or replacement of the purchased part or any part or parts of the system This warranty shall not apply to any type of failure resulting from negligence abuse misuse misapplication improper installation alteration or modification chemical corrosion or improper maintenance There will be a charge for replacement parts or replacement of the entire electrical unit of the defective unit is returned for any of the reasons listed above Ella s Bubbles reserves the sole authori ty to make any type of warranties or representations concerning its products and will not be responsible for any warranties or representations made by any outside source including dealers retailers distributors or contractors Ella s Bubbles does not warrant the installation of any of our products Items include all plumbing or electrical related connections improper or negligent installation of the product A
14. below to submit Via mail Ella s Bubbles LLC Warranty Department 2101 S Carpenter St Chicago IL 60608 Via fax 1 312 666 3551 Via email warranty ellasbubbles com www ellasbubbles com Page 25 02 14
15. e Air Flow Rate Dial On Off O N Push Control Z Ozone m To Hydro Jets E v SSUSHMS dv Nylon Air Tube N L1 N L1 N L1 omod DO c Circuit Breaker Panel www ellasoubbles com Page 12 02 14 UOJIMS 09442913 D IDAIIOV ANY UI UNI Rig den La WNd A _ OJpAH EN sje IV OL IT lt S A PU jer CUDIAH Sef OIDAH JV HO pay poso S DAI JOO J IIDM O1 i S 1 JD H JOLOM qnl I dC C EE EN JV UOIAN SUIT UI MY S I Q0 000 AOLI egn Jy UOJAN ITIFIFIFI N RSA Eee AV r l I A DA AO H AO SS NI KN d 7 j duuy o uouounf ES 109 499 OJIU usn u IOHUOD USNd HO UO OJJUOD USNd HO UO JO OJQUBD SUOZO Tn T gt rm SEN eui peipoipep M SBOHOA O AZI lt hop D xog IDOuIO 3 esnoH C O 9 O E D d N gt Y pg O LLI A d O N x O 9 LLI AC SAM E ETT BDIIOA O N 11 N 17 N m pooj eun 12v DC Power Ni auro is eqn Jv UOIAN Air Switches N NEP xog OJJUO 2 UIDW NN edid JIV ESE oO n eun ging 446 EN SUOZO e iis JO1JUOD CIPAH HO UO AdpJeujouJoJu 2 JOJOONI
16. f the tub has been properly grounded Door Seal has been cleaned with rubbing alcohol to remove any dust or debris left over from construction _ Temperature Control Valve operated on both hot and cold settings _ Both diverters function properly Hand Shower functions on all settings without leaking _ All supply lines have been checked for leaks while both diverters are on Drains open and close properly and the locking nut has been tightened on both stoppers Door seal is water tight after tub has been filled for a minimum of 20 minutes After running for a minimum of 20 Minutes both the Hydro and Air Pumps are functioning properly and all connections to The pumps and jets are water tight Chromatherapy Light and the Ozone Sterilization are working properly When the Ozone is on by itself it will make a light humming noise All drain fittings have been checked for leaks while the tub is draining Unit is installed with access to both plumbing and electrical connections www ellasbubbles com Page 24 02 14 QI Warranty Activation Form by ella s bubbles OWNER S INFORMATION Name Address City State Zip Telephone Email Date Signature Model Serial Number Purchase Date Purchase Price Place of Purchase Contact Name Phone Number Copy of sales receipt must be included with warranty activation forms To activate manufacturer s warranty please complete both pages and use one of the options
17. il the source of the problem has been identified and corrected www ellasbubbles com Page 5 02 14 Drain and Plumbing gt IC by ella s bubbles Make sure that the drain rough in has been placed at the proper location The specifications and drawings shown below and on page 7 are for the Ella Deluxe each model comes with separate specifications please refer each model s specification The dual drain can be connected with a T or Y connection into existing house drain Proper materials must be used based on local plumbing code requirements NOTE Flexible drains are not permitted in some areas The customer and their contractor are responsible for using the appropriate solution to meet the current local construction and plumbing code requirements NOTE Deluxe Model Shown Drain Elbow Options Specifications vary by model please refer to the drawing that matches the model being installed Two Drain Openers with Overflows Front lt U Two 2 Drains I L nr ns Y i lt BM EE i y To P Tra ces lt Y Bel i 2 1 4 Threaded Connection of 2 Drain for Ella s Elbow Drain SIOW HOOI Elbow or Drain Pipe Connection 2 5 16 2 3 16 gt lt 2 3 8 2 5 8 lt Disclaimer In an effort to continually improve our product specifications and configurations are subject to change without notice Before ordering or installing consider futu
18. ill Unlock the door by using the door handle Fully open the door first Then stand up and exit your Ella Walk in Bath NOTE It is recommended to leave the door fully open when not in use to keep the door seal fresh and promote a longer lifetime for the door seal www ellasbubbles com Page 21 02 14 Cleaning and Maintenan CIO by ella s bubbles Ce Recommended Acrylic Cleaners Use only cleaning products whose labels state that they are SAFE for ACRYLIC Always test products on a small are of skirt before applying to complete bath area White Vinegar amp Water Recommended ZEP Professional strength shower tub amp tile cleaner Dawn dish detergent Rubbermaid commercial strength shower tub amp tile cleaner Home Depot HDX shower tub amp tile cleaner Scrub free original soap scum remover Kaboom shower tub amp tile cleaner with oxy clean Simple green all purpose cleaners any scent Simple green lime scale remover Simple green natural bathroom cleaner All tilex products All Pine Sol Products All Fragranzia Products Monthly Maintenance It is recommended that once a month the tub is flushed As well with every month of normal use clean out the pumps inlet cover shown right by unscrewing the cover counter clockwise and removing any hair and debris from the cover and housing Remount the cover in place Never operate the system with the cover off as the pump creates a strong suction and dam
19. lteration made of or alterations or modifications made to the system may cause the product or the system to malfunction Such problems are not covered by warranty TO THE EXTENT PERMITTED BY LAW ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTIC ULAR PURPOSE ARE HEREBY DISCLAIMED Ella s Bubbles and seller hereby disclaim any liability for special incidental or consequential damages Some states provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of special incidental or consequential damages so these limitations and exclusions may not apply to you This warranty gives you specific legal rights You may have other rights which vary from state province to state province May 2013 TOLL FREE 800 480 6850 QI Warranty Activation Form by ella s bubbles INSTALLER S INFORMATION Name Address City State Zip Telephone Email Date 4 0 Signature Upon completing the installation of an Ella Walk In Bath the following Warranty Activation Form must be completed signed by both the customer and installer and returned to Ella s Bubbles LLC In order for the Warranty to be activated faxed scanned or emailed or hard copy mailed To be initialed by the installer s Tub is level in all directions and all support legs are touching the ground Tub is installed on a dedicated 30 Amp GFCI protected circuit using 10 gauge wire Frame o
20. re access to essential equipment www ellasbubbles com Page 02 14 gt IC Preparing the Sub floor by ella s bubbles Prepare the sub floor for the drain and ensure that the area is level The supporting sub floor must be able to support the total weight of the bathtub bather and water Use a level and make sure that the sub floor below the tub is leveled If the floor is not perfectly level adjust the appropriate leveling legs to re align the tub to perfect level It is important that all of the leveling legs are completely supporting the tub touching the floor with equal weight distribution and the tub is leveled for the door seal to work properly If the tub is not perfectly leveled it could result in water leakage and void the warranty Make sure all 8 legs are level RIA ON Black Nu Disclaimer In an effort to continually improve our product specifications and configurations are subject to change without notice Before ordering or installing consider future access to essential equipment Adjustable Height Leg VAY i NOTE Drawing above shows frame layout for Deluxe walk in bath The Companion Elite Petite and Royal frame and drain layouts may very Please reference appropriate specification drawings for proper drain locations Adjust the legs and lower the bath to within 1 16th of an inch above the floor or tile Seal with white silicone or caulking if appropri
21. s in the kit 7 2 Clamp in place the extension panel to the walk in tub shell lining up the facade of top and front 3 Pre drill 3 8 slightly wider E screws washers and bolts 5 Apply Silicone or white caulking as needed 3 amp 4 The extension kit can be installed as needed Opening can be filled as desired www ellasbubbles com Page 17 02 14 Finishing Installation gt by ella s bubbles After all of the water and electrical testing is completed and all fixtures are checked the tub can be installed to the surrounding wall or walls Ella Walk in Baths come with low rise tile lange which allows for two or one wall installations The extension panel of the bathtub can be installed as needed for 60 openings Drywall Drywall Glue Glue Tile Tile RF 5 8 Tub Lip 5 8 Tub Lip Caulking 5 8 Tub Lip Caulking The tub can be finished and filed over as shown in Images Caulking must be applied to joints as needed after the bathtub is installed Threshold Lowering Option Lowering the threshold is an option that can be chosen during installation Because your Ella Walk in Bath is set up for easy installation lowering the threshold requires the drain option to be set up below the floor Page 6 To lower the Walk in Bath threshold First remove the toe kick panel to expose the adjustable leg supports Adjust the height of the tub while keeping the Walk in Bath plumb level on
22. scratches or other damages during the installation and tests Remove the access panels when moving the Walk in Bath and always lift The bathtub from the frame Page 2 Water Test Fill tub for a minimum of 20 minutes to test that the Hydro and Air Pumps are functioning properly before final in wall installation to avoid unnecessary repairs or removal Electrical The unit MUST be connected to a circuit protected by a ground fault circuit interrupter GFCI provided and installed by a licensed electrician and tested periodically refer to instructions provided by GFCI manufacturer A separate 120 Volt and 30 Amp GFCI breaker is required A dedicated line must be run from a breaker to the unit s electrical junction box following your local building and electrical codes Usually the black brown two wire is live hot The blue white wire in the middle is neutral and the green wire bottom is the ground wire A licensed electrician for your area is required to install and test the electrical installation process DO NOT use any kind of extension cords to power the unit Operating the pumps without first filling the bath to above the jets can cause permanent damage to your equipment Push the GFCI Test button into reset mode If the GFCI fails to operate in This manner there is a ground current flow or a device malfunction indicating the possibility of electrical shock If this occurs turn OFF the power and do not use the bathtub unt
23. time warranty under normal use and conditions All supporting equipment motors pumps fixtures electronic controls faucet waste overflow and all plated finishes are covered by a limited five 5 year warranty This warranty is nontransferable and applies only to the original owner The finish warranty does not apply to fading cracking delaminating or blistering due to excessive wear sun fading or scouring due to cleaning This warranty shall not apply to any failure resulting from negligence abuse misuse misapplication alteration or modification or improper maintenance The door warranty is valid only if the alignment of the door is not changed by applying pressure or user s weight hold user s weight to the door or by wrong installation The door is designed to hold its own weight and not designed to hold user s weight Should service be required for any reason of any defect or malfunction of the product during the first five years Ella s Bubbles will ship the part to the original customer s address without charge subject to verification of the defect or malfunction Ella s Bubbles will not be liable for any incidental expenses or material charges in connection with removal or replace ment of the product or parts Delivery time is based on parts availability and location Normally parts are sent out immediately Emailed or mailed photos of defective product and description of the problem is required All mailing notification must
24. ust according to personal preference 6 Using the Air Massage To activate and deactivate the air massage pump push the on off control button Page 10 Notice when adding cool air into the bath water it can lower the water temperature 7 Using the Ozone Sterilization To activate and deactivate the ozone sterilization push the on off control button Page 12 Use the ozone as desired NOTE When the other pumps air and hydro are off and the Ozone generator is left on you will be able to hear the buzzing of the Ozone generator this is normal and only needs to be turned off www ellasbubbles com Page 20 02 14 QI IC Operating Instructions Continued by ella s bubbles 8 Using the LED system The LED Chromatherapy light system may be controlled manually Push the on off control button Page 11 Pull Out Ozone ON OFF Hand Shower Thermostatic gt Control Valve Hand Shower N Diverter N Spout q Diverter Air Flow Control Dial Air Pump ON OFF LED ON OFF Hydro Pump ON OFF 9 Draining the Walk in Bath To drain your Ella Walk in Bath Begin by turning OFF the massage systems Open each of the drains by turning the drain openers clockwise from a down position upward one half turn until fully open Remain in the tub until the water has dropped below the door sill 10 Exiting the Bath Getting out of your Ella Walk in Bath is as easy as getting in to it Wait for the water to drain below the door s

Download Pdf Manuals

image

Related Search

Related Contents

69-ComHRV-F    HPWH Service Handbook (321549  Manuale Uso e Installazione MOTORI TORQUE  Philips T22 E14 User's Manual  User Manual - State of New Jersey Department of Education  ß Hommel Hercules ß ß - HHW Hommel Hercules Werkzeughandel  取扱説明書 - 株式会社中日電子  スライド タイトルなし  80E02 User Manual  

Copyright © All rights reserved.
Failed to retrieve file