Xpelair DX180H User's Manual

image

Contents

1. e READ ALL THESE INSTRUCTIONS amp WARNINGS FULLY BEFORE COMMENCING INSTALLATION e INSTALLATIONS AND WIRING MUST CONFORM TO CURRENT IEE REGULATIONS UK LOCAL OR APPROPRIATE REGULATIONS OTHER COUNTRIES IT IS THE INSTALLER S RESPONSIBILTY TO ENSURE THAT THE APPROPRIATE BUILDING CODES OF PRACTICE ARE ADHERED TO e A QUALIFIED ELECTRICIAN MUST SUPERVISE ALL INSTALLATIONS e THESE APPLIANCES ARE INTENDED FOR CONNECTION TO FIXED WIRING e CHECK THAT THE ELECTRICAL RATING SHOWN ON THE FAN MATCHES THE MAINS SUPPLY e WARNING THESE APPLIANCES MUST BE EARTHED e SITE AWAY FROM DIRECT SOURCES OF HEAT I E GAS COOKERS OR EYE LEVEL GRILLS AND NOT WHERE AMBIENT TEMPERATURES ARE LIKELY TO EXCEED 50 C e WHEN THE FAN IS INSTALLED IN A ROOM CONTAINING A FUEL BURNING APPLIANCE PRECAUTIONS MUST BE TAKEN TO AVOID THE BACKFLOW OF GASES INTO THE ROOM FROM THE OPEN FLUE OF THE FUEL BURNING APPLIANCE e ENSURE THAT ALL RELEVANT SAFETY PRECAUTIONS CORRECT EYE PROTECTION AND PROTECTIVE CLOTHING ETC ARE TAKEN WHEN INSTALLING OPERATING AND MAINTAINING THIS FAN e IF ANY SECTION OF THE DUCTWORK IS POSITIONED HIGHER THAN THE FAN A CONDENSATION TRAP XCT100 MUST BE FITTED AS CLOSE AS POSSIBLE TO THE FAN e GENERAL GUIDANCE FOR SITING THE FAN SEE FIG G ALWAYS SITE FAN AS HIGH AS POSSIBLE e THE APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHILDREN OR INFIRM PERSONS YOUNG CHILDREN SHOULD BE SUPERVISED TO ENSURE THEY DO NOT PLAY WITH THE APPLIANC
2. E a BSI 9 Q TERED CE BS EN ISO 9001 FM11408 QAS 3284 37 INVESTOR IN PEOPLE Sicilian ces iis PREMIER DX180 RANGE Centrifugal Bathroom Fan Installation and Operating Instructions DOUBLE POLE ISOLATING SWITCH 92 DIA PREMIER DX180T FRONT VIEW HOLE FIXING FIXING HOLE DOUBLE POLE ISOLATING SWITCH PREMIER DX180H SL LAMP Saa CY IF REQUIRED ON OFF SWITCH IF REQUIRED DOUBLE POLE ISOLATING SWITCH Please leave this leaflet with the fan for the benefit of the user Leaflet No 567 2068 04A
3. What you will need e To fix these fans through a wall you will need Wall Vent Kit VK10 e To fix these fans through a glass window or panel you will need Glass Mounting Kit GMK e To fix these fans through a caling you will need Ceiling Mounting Kit XCMK e A double pole isolating switch with a minimum contact gap of 3mm e Suitably rated 3 core or 4 core cable e A ceiling or wall on off switch with built in indicator DX180T DX180H in a wall Surface mounting 1 Mark on the wall the centre of the duct holei 2 Use this centre to cut an opening through the wall 117mm with a Slight fall to the exterior 3 Fit the wall tube not supplied and mortar into place If installing in a wall flush mounting 1 Mark on the wall the centre of the duct holel and drill a pilot hole through both walls at a slight downward angle 2 Use the centre to mark a rectangular hole for the inner wall usng the dimensions A 3 Cut the rectangular hole through the inner wall 4 Go outside and cuta 117mm hole in the outer wall using the small hole as the centre 5 Measure the wall thickness Cut the wall tube not supplied so that itis 64mm less than the wall thickness If installing in a ceiling surface mounting This method requires a space above the ceiling such as a loft or attic to provide access for 100mm internal diameter ducting 1 Mark on the ceiling the centre of the duct hole avoiding ceiling joists and b
4. clips erminating the ductino Fit an outer grille to the outer wall For ceiling mounting use appropriate ancillaries Wire the electrical connections WARNING THIS APPLIANCE MUST BE EARTHED 1 Isolate the electricity supply and remove all fuses The terminal block will accept cable up to 2 5mm Use a double pole isolating switch with a minimum contact gap of 3mm in both poles Use suitably rated 3 core or 4 core cable dependant on application Remove the retaining screws of the terminal cover if still in position Wire the fan as shown inf using the cable clamp provided Check fan model to diagram Replace the terminal cover H and fasten the retaining screws See section on User adjustments if you wish to use settings other than those that have been factory set Refit the front cover fl Fig Connect the cable from the isolating switch to electrical supply wiring and re check installation 10 Refit fuses before turning on electricity supply 11 For fixed wiring circuits the protective fuse for the appliance must not exceed 5A Ww N Dr N N w o1 ID W oo For Australia Only Permanently connected to the supply and a remote switch controls operation They should be directly wired to the supply through an approved 10A wall mounted surface switch with at least 3mm clearance between contacts User adjustments Before making any adjustments isolate the fan completely from the ma
5. ducting 7 Fix the fan box J to the wall using suitable screws or to the ceiling using appropriate fasteners not supplied in a wall flush mounting The surround fi is not required Fit the ducting to the circular spigot 1 Assemble the three fan body clamps to the fan box using Suitable screws Slit the cable grommet Pass the electrical cables into the fan box through the cable inlet hole and cable grommet Ensure cable grommet is in place and a tight fit Offer the fan box up to the wall Tighten up the three screws until the fan is clamped to the inner wall The fan body clamps will rotate to an automatic stop position DO NOT OVERTIGHTEN If mounting in a ceiling flush mounting The surround fi is not required N TET 1 Insert the fan se the hole and mark four positions using the Slots in the flange Remove the fan box from ceiling and fit four suitable ceiling clips over the edge of the hole so that the clips align with the marks on the ceiling Drill 4 pilot holes into the ceiling through the hole of each clip ensuring not to damage the clip and fit the clips ensuring correct alignment Fit the ducting to the circular spigot Offer the fan box up to the ceiling Slit the cable grommet Pass the electrical cable into the fan box through the front cable inlet hole Ensure cable grommet is in place and a tight fit Using suitable screws fl F ig fix the fan box flange to the ceiling
6. ins supply check specification below to see which features apply to your fan 1 Remove the front cover and replace after adjustment Fig Premier DX180 e There are no user adjustments for this fan Premier DX180T e There are no user adjustments for this fan Premier DX180H The humidity setting is adjustable between approximately 50 and 90 relative humidity Use an electrician s screwdriver and turn screw RH Fig clockwise to increase the relative humidity setting and anti clockwise to decrease Note the fan is more sensitive at 50 RH than at 90 and is factory set at approximately 70 Using the fan Premier DX180 Operate the fan using the external on off switch Repeat to switch off Premier DX180T Operate the fan using the external on off switch Repeat to switch off When the switch is turned off the fan continues to operate for the over run timer period Fixed at approximately 20 minutes Premier DX180H Switched Operation The fan can be wired with a separate on off switch Fan operates at condensation speed when switched on When switched off the fan will continue to operate if the humidity level exceeds the set level Condensation Operation The fan operates at condensation control speed when the relative humidity exceeds the set level and turns off when the humidity drops Cleaning 1 Before cleaning isolate the fan completely from the mains supply 2 Only clean the external
7. surface of the fan using a damp lint free cloth 3 Do not use strong detergents solvents or chemical cleaners Allow fan to dry thoroughly before use 5 Apart from cleaning no other maintenance is required SS Te Front Cover Impeller Screws Terminal Cover Fan Box Circular Spigot Clamp Screws and Wall Plugs Fan Body Clamps Foam Tape 0 Surround 1 Ceiling Screws Diagram g e e OO NODU amp WN e Guarantee UK This fan is guaranteed against defects for 2 years from the date of purchase e Xpelair reserve the right to repair or replace the fan e Keep your purchase receipt e Any problems contact the address below Outside UK See International section below echnical Advice amp Service UK Xpelair have a comprehensive range of services including e Free technical advise Help Desk from Engineers on all aspects of ventilation e Free design service quotations and site surveys Outside UK See International section below Please ask for details on Tel 44 0 8709 000430 Fax 44 0 8709 000530 Also at the address below Head Office UK Sales Office and S Applied Energy Products Ltd Morley Way Peterborough PE2 9J J England Tel 44 0 1733 456789 Fax 44 0 1733 310606 Sales Spares Hotline 44 0 8709 000420 Sales Spares Faxline 44 0 8709 000520 Web http www xpelair co uk International Guarantee Contact your local distributor or Xpelair direct IMPORTANT
8. uried cables etc 2 Cuta 117mm hole using the marked centre If installing in a ceiling flush mounting For 100mm ducting 1 Mark a rectangular hole using the dimensions 2 Cutthe hole avoiding ceiling joists and buried cables etc For flat ducting e This fan can be installed within a 47mm void without the circular spigot F ig H Flat ducting adapter F DA available Preparing the fan for installation 1 Remove the front cover fi F ig 2 Fit the foam tape f around the circular spigot Fig fa 3 Remove the electrical cover M Fig The impeller can be removed to aid access if required This is a oush on pull off assembly the fan in a wall or ceiling surface mounting 1 Place the ducting into the hole and align to the required position If wall mounting ensure that the ducting slopes down and way from the fan 2 Mark the positions of the three fixing holes I in fan box Fig a 3 If wall mounting drill three holes 5 5mm diameter for wall plugs If ceiling mounting use suitable fasteners not supplied 4 Cutoutthe cable inlet hole if required in the surround and slit the cable grommet Slide the surround Ii over the fan box 5 Pass the electrical cables into the fan box through the rear cable inlet hole and re fit the cable grommet Ensure that cable grommet is in place and a tight fit 6 Offer the fan box up to the wall or ceiling Ensure the circular spigot enters the