WhisperKool EXTREME 5000TIR User's Manual

image

Contents

1. Non Flush Installation Flush Installation Page 19 LIQUID MEASURING THERMOSTAT SYSTEM The WhisperKOOL Series cooling units come equipped with a liquid temperature measuring thermostat system This system incorporates the following advantages 1 Self Calibrating Probe The probe contains a sensor chip which actually communicates back and forth to the thermostat This results in a consistent temperature setting and accuracy Do not remove the tip from the probe 2 Heavy duty Circuitry The circuitry within this new unit has been upgraded to resist power surges which play havoc on electrical components This improvement will ensure years of trouble free use However for the highest reliability we recommend that the customer install a surge protector for the unit itself Measuring liquid temperature has a few unique advantages 1 Wine temperature is kept in a very precise controlled environment This assures a consistent temperature 2 By measuring the liquid temperature rather than air the unit will operate 75 80 of the time To Use the thermostat 1 Locate an empty wine bottle 2 Fill 3 4 full with room temperature tap water 3 Place bottle probe securely into bottle 4 Place bottle with probe level and to the side of the unit in your wine cellar It is recommended that it is placed in a central location of your wine cellar Avoid pulling too much on the probe cord It may become disconnected r
2. 6 This limited warranty is void ifthe factory applied serial number has been altered or removed from the Product 7 Removing the rivets from the Product s unit housing without prior authorization from WhisperKOOL voids this limited warranty 8 The End User must first contact WhisperKOOL Customer Service by telephone at 1 800 343 9463 prior to attempting service on any Product still under the limited warranty else the limited warranty is voided 9 THE REPAIR OR REPLACEMENT OF THE PRODUCT AS PROVIDED UNDER THIS LIMITED WARRANTY IS THE EXCLUSIVE REMEDY OF YOU THE END USER AS WELL AS ANYONE ELSE IN THE CHAIN OF TITLE OF THE PRODUCT DOES NOT START A NEW LIMITED WARRANTY TIME PERIOD AND IS IN LEIU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED WITH REGARD TO THE PRODUCT IN NO EVENT SHALL WHISPERKOOL BE LIABLE FOR INCIDENTAL CONSEQUENTIAL SPECIAL OR CONTINGENT DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY EXPRESSLY DISCLAIMED Some states do not allow the exclusion or limitation of incidental or consequential damages or allow limitations on how long an implied warranty lasts so the above limitations or exclusions may not apply to you This limited warranty gives you specific legal rights and you may have other rights which vary from state to state 10 Failure of the End User to comply with all of the Product Installation Requ
3. cut out Frame the hole with two by four supports Page 14 PT EXPL5000 060311 INSTALLATION TEST THE UNIT PRIOR TO INSTALLATION To prepare it for testing before installation in wall e Unit needs to be in the upright position for 24 hours before starting Remove unit from box Place unit on tabletop e Plug in unit to electrical outlet Plug in bottle sensor e Turn on to test Should be 10 F 15 F across coils approx 20 30 minutes e Turn off after test e Remove bottle sensor Electrical Needs The WhisperKOOL Extreme System requires a dedicated 115 volt 20 amp circuit The unit draws a large amount of amps at initial start up By designating a dedicated circuit breaker you will guarantee the unit has enough power to run effectively Contact an electrician for assistance with the installation of this dedicated electrical circuit 1 Match the electrical outlet to the plug provided on the WhisperKOOL unit 2 Provide a dedicated circuit and wiring for the unit 3 Provide a weatherproof plug for units connected outside Electrical Inlets The unit is equipped with two power inlets One is located on the right side of the unit inside the cellar the other is located on the rear of the unit outside of the cellar Use the selector switch located on the right side of the unit to select which power inlet you would like to utilize Meaning if you would like to plug the unit into a socket outside of the cellar set the selector s
4. duties levies or fees imposed on WhisperKOOL or Purchaser by any taxing authority related to Purchaser s order Payment for a WhisperKOOL Product must be made in lawful money of the United States of America in immediately available funds WhisperKOOL accepts all major credit cards WhisperKOOL may change payment terms for unfilled orders if in WhisperKOOL s reasonable opinion Purchaser s financial condition previous payment record or relationship with WhisperKOOL merits such change All Purchaser orders whether written or verbal are governed by these Terms and Conditions and are subject to acceptance by WhisperKOOL Any term or condition which may be included on any Purchaser s purchase order or in any form of communication whether verbal or in writing from any Purchaser to WhisperKOOL that is not identical with these Terms and Conditions is hereby expressly objected to and rejected by WhisperKOOL and shall NOT become a part of the contract of sale of any Product WhisperKOOLs failure to object to any such conflicting term and or condition of sale contained in any communication including a purchase order from a Purchaser shall not be considered as acceptance of such term and or condition or as a waiver of these Terms and Conditions The only language in which WhisperKOOL states these Terms and Conditions is English WhisperKOOL reserves the right in its sole discretion to change these Terms and Conditions at any time for any reason without
5. fungal growth that cause unpleasant odors and indoor air quality problems If mold is found remove it immediately and sanitize that portion of the unit Page 10 PT EXPL5000 060311 Mounting the Unit The unit must be mounted within 18 of the top of the room in order to achieve sufficient cool ing Asthe room cools down the warm air will rise to the ceiling Mounting the WhisperKOOL high in the room will create a consistently cool environment by capturing the warm air and replacing it with cool air Mounting the unit low in the room will result in a temperature variation in the room due to the unit s inability to draw warm air from the ceiling of the cellar to the unit itself and cold air settling to the floor Door and Door Seal An exterior grade 1 3 4 door must be installed as a cellar door It is very important that weather stripping is attached to all 4 sides of the doorjam A bottom sweep or threshold is also required The door must have a very good seal to keep the cool cel lar air from escaping out of the cellar One of the most common problems with cool ing units running continually is due to the door not sealing properly In cases where glass doors are used and the room size is close to the recommended unit size the 6 next larger size WhisperKOOL should be amp used This will compensate for the insula tion loss due to the lower insulating rating of glass NF ExhaustRoom _ 77 Wine Cella
6. notice WhisperKOOL shall not be liable to Purchaser for any delay of delivery of a Product caused by Force Majeure or any other cause beyond WhisperKOOL control 2 WHISPERKOOL PRODUCT LIMITED WARRANTY A Two 2 Year Limited Warranty For the period of TWO 2 YEARS the Limited Warranty Period from the date of original sale of a Product by WhisperKOOL if a WhisperKOOL Product is found to be defective in material or workmanship after undergoing WhisperKOOL s customer service troubleshooting then subject to the WhisperKOOL Product Limited Warranty Limitations and Exclusions as well as the other Terms and Conditions stated herein WhisperKOOL will do the following as appropriate for the end user End User who has installed and is actually using the Product with regard to LABOR PARTS and FREIGHT 1 LABOR repair or replace at WhisperKOOL s sole option the Product at no charge to the End User and 2 PARTS supply at no charge to the End User new or rebuilt replacement parts for the Product in exchange for the return of defective parts and 3 FREIGHT cover normal ground freight charges for parts and in the event the Product is not repairable in the field cover normal ground freight charges within the continental United States for the repair or replacement of the Product B Five 5 Year Compressor Limited Warranty The two 2 year limited warranty period stated in Section 2 a above is extended for an addition
7. representative will be able to assist you with your questions and warranty information more effectively if you provide them with the following e The model and serial number of your WhisperKOOL Series Unit e Location of unit and installation details such as ventilation ducting construction of your wine cellar and room size Contact WhisperKOOL Customer Service 1738 E Alpine Avenue Stockton CA 95205 www whisperkool com Email support whisperkool com Phone 209 466 9463 US Toll Free 800 343 9463 Fax 209 466 4606 ACCESSORIES FOR COOLING UNITS WhisperKOOL offers accessories to enhance and customize your Extreme wine cooling unit Platinum Extreme Exterior Grille Protects the Platinum Extreme systems from the weather elements when placed on the exhaust side e Small Exterior Grille used for Platinum Extreme 5000ti amp 5000tiR Condensate Pump Kit The condensate pump kit is designed as an automatic condensate removal pump for water dripping out of our cooling units drain line The pump is controlled by a float switch mechanism that turns the pump on when approximately 2 1 4 of water collects in the tank and automatically switches off when the tank drains to approximately 1 1 4 The condensate pump kit allows the excess condensate to be pumped up to 20ft away from the unit Extreme Ducting Plenum Ducting Plenum can be used with the Platinum Extreme 4000 5000ti 5000tiR or 8000ti This plenum allows either side
8. to 6 hours but can be changed between 0 23 5 hours Con Cof Compressor On time Con and Off time Cof with a Probe 1 failure Alarm These parameters are set at Con 40 min Cof 10 min In the event that there is a Probe 1 failure Alarm the compressor refrigeration system automatically starts a predetermined ON OFF cycle which is controlled by the Con and the Cof parameters The customer can adjust these parameters to maintain the desired Bottle temperature Alarm Codes message Jen Bottle Probe is Unplugged Attach Bottle Probe to Unit Faulty Bottle Probe Connection 1 Check Bottle Probe attachment at circular connector 2 Check Bottle Probe connection at green terminal block on back of controller Defective Bottle Probe Replace the Bottle Probe Faulty Evaporator Probe Check Evaporator Probe connection at green terminal block on Connection back of controller Defective Evaporator Probe Replace the Evaporator Probe Defective Bottle Probe Replace the Bottle Probe The Bottle Probe is sensing a Allow the room to warm up which will increase the temperature temperature of 4 below the set of the wine point Defective Bottle Probe Replace the Bottle Probe The keypad is locked Hold Up and Down buttons for 3 to 5 seconds to disable PON should appear Page 31 REMOTE WIRE SCHEMATIC XW260K x a weld To Remote keyboard 1 3 r Buwweibord 104 Front Rea
9. 5000ti EXTREME OWNER S MANUAL FOR 5000ti 5000tiR Whisper KOOL The Coolest Thing In Wine Stor Copyright O 2011 WhisperKOOL All rights reserved This manual the product design and the design concepts are copyrighted by WhisperKOOL with all rights reserved Your rights with regard to the hardware and manual are subject to the restrictions and limitations imposed by the copyright laws of the United States of America Under copyright laws this manual may not be copied reproduced translated transmit ted or reduced to any printed or electronic medium or to any machine readable form for any purpose in whole or in part without the written consent of WhisperKOOL Every effort has been made to ensure that the information in this manual is accurate WhisperKOOL is not responsible for printing or clerical errors WhisperKOOL reserves the right to make corrections or improvements to the information provided and to the related hard ware at any time without notice Vinoth que and WhisperKOOL are registered trademarks and ECE is a trademark of WhisperKOOL All rights reserved Mention of third party products is for informational purposes only and constitutes neither an endorsement nor a recom mendation WhisperKOOL assumes no liability with regard to the performance or use of these products 6 03 11 PT EXPL5000 060311 TABLE OF CONTENTS WhisperKOOL Extreme Series Quick Reference Guide 4 Controller Quick Reference G
10. DITIONAL TERMS AND CONDITIONS a Return Policy All return inquiries must be made within thirty 30 calendar days of the original purchase of a Product and are subject to a twenty five percent 25 restocking fee Shipping costs are not refundable and the Purchaser is responsible for all return shipping costs including customs fees and duties if applicable b WhisperKOOL retains a security interest in each Product until payment in full c Every provision of these Terms and Conditions shall be construed to the extent possible so as to be valid and enforceable If any provision of these Terms and Conditions is held by a court of competent jurisdiction to be invalid illegal or otherwise unenforceable such provision will to the extent so held be deemed severed from the contract of sale between Purchaser and WhisperKOOL and all of the other non severed provisions will remain in full force and effect d The laws of the State of California without regard for conflicts of law shall govern the construction and enforcement of the these Terms and Conditions except that these Terms and Conditions shall be interpreted as through drafted jointly by WhisperKOOL and Purchaser Any dispute will be resolved by the courts in the County of San Joaquin State of California and all parties WhisperKOOL Purchaser and End User hereby irrevocably submit to the personal jurisdiction of such courts for that purpose No waiver by WhisperKOOL of any breach or d
11. For your convenience the Whisperkool unit has two power inlets one on the side of the unit and the other on the back Use the selector switch located on the right side of the unit to select the inlet you would like to use 5 The unit is designed to gently cool down the temperature of the cellar over time by cycling cooler and cooler air throughout Test the unit prior to installation Operate unit for twenty minutes While the unit is running and working properly the air discharged from the front should be 10 15 F cooler than the air in the room This means that in an environment where the air is 80 F the unit will discharge air that is 65 70 F 6 It is REQUIRED to install a drain line to remove excess condensation from the unit 7 The WhisperKOOL unit is intended for use in properly designed and constructed wine cellars Hire a professional wine storage consultant with a valid contractor s license to build your wine cellar Refer to the How to Build a Wine Cellar video available on the Whisperkool website at www whisperkool com 8 Install the foam strips along the inside edge of the unit s flange to assure a proper seal against the wall Never try to open the WhisperKool unit repair it yourself or use a service company without WhisperKool s authorization This will void your warranty If you encounter a problem with your WhisperKool unit please refer to the Troubleshooting Guide on pages 34 35 If you have any further quest
12. L Extreme Series Owner s Manual Registration Warranty Card Accessory Kit Two e Power Cord e Mounting Bracket Insulation Foam 14 1 4 2 Mounting Bracket Insulation Foam 15 34 2 Bottle Temperature Probe Standard Unit Accessory Kit Three e 13 Standard Screws 9 1 2 Self Tapping Screws 9 e 1 2 x 1 2 Barbx MNPT Fitting e Drain Line tube 1 e Connection T 1 Please leave the WhisperKOOL unit in its original box until you are ready for installation This will allow you to move the product safely without damaging it When you are ready to remove the product from the box refer to page 15 for installation instructions Note Save your box and all packaging materials They provide the only safe means of transporting shipping the unit Page 8 PT EXPL5000 060311 QUICK START GUIDE This guide is meant to serve as a quick reference for installation of the WhisperKOOL unit The remainder of this Owner s Manual will provide more detailed information and instructions Upon receiving the WhisperKOOL unit 1 Inspect the unit before installation If damage is found please contact your distributor or WhisperKOOL Customer Service at 1 800 343 9463 ext 799 2 The unit should remain in an upright position for 24 hours prior to operation 3 The WhisperKOOL unit requires a dedicated 120 volt 20 amp circuit Use a surge protector with the WhisperKOOL unit Do not use a GFI Ground Fault Interrupter line 4
13. al three 3 year period with regard to a WhisperKOOL Product s compressor only Labor freight and parts ancillary to the compressor remain subject to the two 2 year limited warranty C Product Warranty Limitations and Exclusions 1 This limited warranty does not cover cosmetic damage caused during installation damage due to acts of God commercial use accident misuse abuse negligence or modification to any part of the Product Delivery and installation of the Product any additional parts required as well as removal of the Product if warranty work is required are all at the sole cost risk and obligation of the End User 2 This limited warranty does not cover damage due to improper installation or operation or lack of proper maintenance of the Product connection of the Product to improper voltage supply or attempted repair of the Product by anyone other Page 37 than a technician approved by WhisperKOOL to service the Product 3 This limited warranty does not cover any Product sold AS IS or WITH ALL FAULTS 4 This limited warranty is valid only in the continental United States Alaska and Hawaii Sales elsewhere including Puerto Rico are excluded from this warranty 5 Proof of purchase of the Product in the form of a bill of sale or receipted invoice which is evidence that the Product is within the Limited Warranty Period must be presented by the End User to WhisperKOOL in order to obtain limited warranty service
14. ance from the ceiling and top of the unit is no more than 18 One or more of the fans is not turning on Call Customer Service at 800 343 9463 Compressor is not turning on Call Customer Service at 800 343 9463 Compressor keeps cycling on overload Make sure all fans are working and there are no airflow obstruction Poor seal around door Make sure there are no air gaps around the door If door seal is damaged replace it Controller set too high Lower the set point Evaporator coil is frosted or iced up Page 34 Observe ice formation pattern If only part way up the coil face unit could be low on refrigerant If so call Customer Service at 800 343 9463 PT EXPL5000 060311 TROUBLESHOOTING GUIDE Possible Cause Solution Unit is not level Unit should be level in wall to prevent leaking Drain line clogged or kinked Check drain line to make sure water can flow freely Drain is clogged preventing water form escaping Disconnect drain and clear out open access door and check drain for blockage Drain line does not have a downward slope Fix Drain line so there is a downward slope from the unit to the drain Coil is iced causing drain pan ice and water overflowing Melt ice with blow drier Soak up with a towel Possible Cause Solution Lack of air flow Make sure fan is unobstructed clean evaporator if necessary Compressor not running Call Customer Service at 800 343 9463 Uni
15. best components and closely controlling our manufacturing processes we can assure the highest quality lowest defect manufacturing rates in the industry Page 3 WHISPERKOOL Series QUICK REFERENCE GUIDE Front Side View Bottle Probe O Controller Probe Input a H Extreme 5000 t WhisperKOOL O A En S Control Panel see page 15 for details Speed Control Front Grille Rear View n HE mt ne C MH Eo we HH HH HH HM E HHQH IH IHH HHIH IHH MH E p DH HH Posterior Grille HH LHH HH HH HH na eel ie ni i H LAN HH tH el DHH HH HH Rear Power Option J Drain Port I Page 4 PT EXPL5000 060311 QUICK CONTROLLER REFERENCE GUIDE Standard Controller Layout XR70CX If your unit is installed through the wall and does not have a remote keypad you will have the XR70CX Controller Note The 1 or 3 5 qualifies the amount of time in seconds that the button must be pushed to activate the feature Refer to page 25 27 for complete instructions Energy Saving Evaporator and Condenser Fan Button 1 Hi Bottle Temp History amp Scroll Button 1 Push to see the max stored temperature In programming mode use to browse the parameter codes or increase the display value Hold for 3 seconds to start fast freezing cyc
16. ct The End User is responsible for all risks and costs of removing the Product if limited warranty work is required f The Product cannot operate at its optimum capacity if airflow is constricted by ducting or venting the exhaust side of the Product into a location with inadequate ventilation 4 MAINTENANCE REQUIREMENTS It is the End User s responsibility to clean off any accumulated dust lint or other debris from the front and rear intake grills failure to do this on a regular basis will restrict the airflow and may affect the Product s ability to function properly Periodically cleaning the Product s vents will help assure maximum cooling efficiency The drain tube must also be checked and kept clean and free of debris and mold to maintain proper performance Mold is a natural living organism in the environment It exists in the air in the form of microscopic spores that move in and out of buildings through doors windows vents HVAC systems and anywhere else that air enters Once it is discovered mold must be addressed quickly and appropriately Delayed or improper treatment of mold issues can result in costly and reoccurring repairs If the End User suspects a mold problem it is always best to hire a qualified and experienced mold remediation specialist 5 ADDITIONAL END USER RESPONSIBILITIES The following items are not covered under any warranty and are the sole responsibility of the End User a End Users should satisfy themselves
17. ds and the CPC logo will be displayed on the digital display The CPC feature can be terminated by pressing the Up button for 3 5 seconds or the feature will self terminate after 6 hrs 1 The CPC Feature may be used to Pre Chill the Cellar prior to loading it with Warm Product The feature will shift the Set Point down to a lower setting of 52 F for the next 6 hours After the 6 hour time period the Set Point will automatically return to the original Set Point The CPC feature can be conveniently adjusted to the customer s specific needs by accessing the Customer Preference Select Mode CPSM See Customer Preference Select Mode Instructions Page 29 Set Button CPSM Mode Page 30 Press the Set button once and it will display the Set Point After approximately 5 seconds the display will return to normal operation and display the Bottle Probe temperature Press the Set button once and it will display the Set Point Press the up and down arrows to change the set point Press the Set button again and the numbers will blink confirming the change in Set Point Press and hold the Set button during the display of the Hi Low Temperature Data History hold button unit rst blinks on display and it will erase the past recorded data file and start recording from the current time and temperature Press the Set and the Down Arrow buttons simultaneously for 3 5 seconds and y
18. e original Set Point The CPC feature can be conveniently adjusted to the customer s specific needs by accessing the Customer Preference Select Mode CPSM See Customer Preference Select Mode Instructions Page 25 Energy Reduction ER Set Button CPSM Mode Page 26 The ER feature can be used to save energy and aids in extending the life of the sys tem The ER button is located at the top L H side of the control The ER feature is acti vated by pressing the ER button one time and the ER logo will appear on the digital display The purpose of the ER feature is to reduce energy cost by shifting the Set Point up by 4 degrees which will allow the cooling system to run for shorter periods of time resulting in a reduction in energy cost The ER feature allows for Energy Savings at any time During periods of high ambi ent temperatures vacations or business travel To deactivate the ER feature press the ER button one time and the ER logo will turn off The ER feature can be conveniently adjusted to the customer s specific needs by accessing the Customer Preference Select Mode CPSM See Customer Preference Select Mode Instructions Press the Set button once and it will display the Set Point After approximately 5 seconds the display will return to normal operation and display the Bottle Probe temperature Standard Controller Press and hold the Set button for 3 5 second
19. efault of the contract of sale including these Terms and Conditions concerning a Product will be deemed to be a waiver of any preceding or subsequent breach or default 9 Questions or Additional Information Ifyou have any questions regarding these Terms and Conditions or wish to obtain additional information contact us via phone at 1 800 343 9463 or please send a letter via U S Mail to WhisperKOOL 1738 E Alpine Ave Stockton CA 95205 supportewhisperkool com Model Extreme Serial Number A Installed by Date Page 39 WhisperKOOL WhisperKOOL 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www whisperkool com
20. el can be installed or mounted sepa rately from the cooling unit itself remotely using the supplied cable This option provides unique flexibility for installing the Extreme Series cooling unit in your wine cellar The remote option must be specified when the unit is ordered Note Remote Control is generally standard with a Ducted Unit Ducting and Ventilation Options The ventilation system is ideal for ducting The option al collars fit standard ventilation ducting allowing the installer to vent air to and from the unit for optimum performance please see specifications for details PT EXPL5000 060311 STANDARD CONTROLLER FUNCTIONS XR70CX If your unit is installed through the wall and does not have a remote keypad you will have the XR70CX Controller Energy High Temp Pre Chill Reduction 9 p Low Temp Display N OFF Set Point ON O TEMPERATURE Button Normal Functions ON OFF The ON OFF button allows the customer the convenience of turning the refrigera tion system ON or OFF from the control panel This feature does not disconnect power from the unit In order for the power to be shut off from the unit the power cord must be unplugged from the wall receptacle Press the ON OFF button once for button application Up and Down Use these buttons to scroll up or down the CPSM Customer Preference Selection Arrows Mode menu Displays the Highest and Lowest temperature sensed by the Bottle Probe This feat
21. ently to 55 F as long as the ambient temperature of the area that it is exhausting to does not exceed 110 F Therefore you want to exhaust the unit in a room which will not exceed 110 F Otherwise the unit will not have the capacity to keep the wine at a desirable 55 F Back Exhaust Room Front Wine Cellar Exhaust Fan WhisperKOOL side view Air Intake Cellar Wall How to Build a Wine Cellar Instructional Video WhisperKOOL has a construction tutorial available on line at our website www whisperkool com This tutorial will walk you through the steps of constructing a properly built wine cellar and the installation of our WhisperKOOL product line Page 12 PT EXPL5000 060311 Sizing the Unit to the Room Cellar Volume AMP s AMP s Product Dimensions cubic feet starting running WxHxD 5000ti tiR 1000 high 14 25 x 16 x 28 5000ti tiR 1000 med 14 25 x 16 x 28 5000ti tiR 1000 low 14 25 x 16 x 28 Cutting the Hole for the WhisperKOOL Unit Level Tools Needed Hammer Locate the desired installation location Using a stud finder locate the studs on either side of the center point and mark them with vertical lines Using a level and a pencil mark a horizontal line on the wall between the two studs approximately 1 1 2 or as close as possible if more than 1 1 2 from the ceiling Using a ruler or measuring tape measure 16 1 4 down and mark another horiz
22. esulting in non operation of the unit Note The thermostat can be set between 50 F and 67 F Remember The WhisperKOOL System is based on the temperature of the water Do not be misled by thermostats reading air temperature The air temperature in the cellar will be cooler than the liquid temperature of the wine while it is coming to optimum balanced temperature Fill an empty bottle with room temperature water then insert the probe Page 20 PT EXPL5000 060311 REMOTE CONTROLLER INSTALLATION AND CONFIGURATION The WhisperKOOL Extreme Series can be configured with a remote controller system If you have a unit with a remote controller please review this section The controller can be installed up to 50 feet away from the cooling unit or up to 300 feet away with the extend ed connection wire To install the remote controller remove the mounting bracket and secure the bracket to the wall in the desired location Reattach the controller to the bracket ug ET e 7 D Mounting Bracket Attach the connection wire as shown below with the red wire in the upper connection slot and the black wire in the lower slot Red Wire Black Wire Page 21 Connection wire in Side Mount configuration Connection wire in Rear Mount configuration Below is an illustration of one possible way to configure the remote controller in a wine cellar Cooling Unit Remote Controller Pa
23. f 15 and a minimum of 0 After any adjustment to Humidity Enhancement you should wait a minimum of three days before making any additional adjustments This will allow the cellar suf ficient time to acclimate to the new setting Fof Humidity Management Enhancement This parameter is normally set at 15 This parameter should not be adjusted as it simply provides an OFF cycle time for the fan during the compressor OFF cycle However the parameter is located within the CPSM as a convenience to the customer should it need to be adjusted PT EXPL5000 060311 CCS Cellar Pre Chill Set Point This parameter is set at 52 but can be adjusted to a set point between 50 67 CCT Cellar Pre Chill Duration This parameter is set to 6 hours but can be changed between 0 23 5 hours Con Cof Compressor On time Con and Off time Cof with a Probe 1 failure Alarm These parameters are set at Con 40 min Cof 10 min In the event that there is a Probe 1 failure Alarm the compressor refrigeration system automatically starts a predetermined ON OFF cycle which is controlled by the Con and the Cof parameters The customer can adjust these parameters to maintain the desired Bottle temperature Hes Differential for Energy Reduction This parameter is set at 4 above the set point dur ing the Energy Reduction mode A decrease in this setting will decrease the set point and an increase in this feature will increase the set point AUX
24. ge 22 PT EXPL5000 060311 MULTI SPEED CONTROL Designed for wine cellars from up to 1000 cubic feet the Extreme 5000ti features multi speed fans with a high setting for maximum performance in high temperature 110 F environments and a low setting for super quiet operation Fan Speed Selector Switch Low Med High The cooling unit fans operate on 3 speed settings Low Medium and High For optimum sound and energy efficiency select the lowest fan speed that will maintain the desired cellar temperature High speed is recommended for initial cellar cool down extreme temperature conditions and ducted installations PRR EE EEE HHH ES Extreme 5000 i WhisperKOOL RARE Og OR EEES SG RR 090905020202020200020200020 20200000 20 Page 23 SYSTEM OPERATION Standard and Remote Controllers Initial Start Up When power is applied to the unit the control will briefly display all symbols and the Compressor sym bol will be displayed if unit is calling for cooling There may be a brief delay prior to the evaporator and condenser fans turning on as the fans will not turn on until the sensors reach their perspective start tempera tures below 120 F for the evaporator and condenser When the evaporator and condenser fans are activat ed the FAN symbol will turn on Normal System Cycle After the bottle probe has reached the set point all units are shipped w
25. indicates that the evaporator temperature is below 26 Alarm Codes message cause n CS Bottle Probe is Unplugged Attach Bottle Probe to Unit Faulty Bottle Probe Connection 1 Check Bottle Probe attachment at circular connector 2 Check Bottle Probe connection at green terminal block on back of controller Defective Bottle Probe Replace the Bottle Probe Faulty Evaporator Probe Check Evaporator Probe connection at green terminal block on Connection back of controller Defective Evaporator Probe Replace the Evaporator Probe Defective Bottle Probe Replace the Bottle Probe The Bottle Probe is sensing a Allow the room to warm up which will increase the temperature temperature of 4 below the set of the wine point Defective Bottle Probe Replace the Bottle Probe The keypad is locked Hold Up and Down buttons for 3 to 5 seconds to disable PON should appear Page 27 STANDARD WIRE SCHEMATIC XR70CX Front Rear Receptacle Receptacle 15 Amp Circuit Breaker Crankcase Heater Line El 9 10 11 12 8A 120v AN Hot Key IV probe TTL or X REP PT EXPL5000 060311 Page 28 REMOTE CONTROLLER FUNCTIONS XW260K If your unit has a remote keypad then you will have the XW260K controller High Temp Pre Chill Low Temp Display Set Point ON OFF DIXELL TEMPERATURE ON OFF The ON OFF button allows the customer the convenience of turning the refrigera tion sys
26. ions concerns or need assistance please contact WhisperKool Customer Service at 1 800 343 9463 ext 799 Please be sure all testing has been completed prior to contacting Customer Service Please have your results ready for your representative Page 9 PREPARING THE WINE CELLAR The performance and life of your WhisperKOOL unit are contingent upon the steps you take in preparing the wine cellar Note Improperly preparing your enclosure or incorrectly installing your WhisperKOOL unit may cause unit fail ure leaking of condensation and other negative side effects IT IS HIGHLY RECOMMENDED THAT YOU OBTAIN THE ASSISTANCE OF A WINE STORAGE PROFESSIONAL Wine storage professionals work with licensed contractors refrigeration technicians and racking companies to build well insulated beautiful and protective wine cellars WhisperKOOL has put together some useful tips to assist in the installation process Our recommendations are meant to act as a guide in the process of building a proper enclosure Your intended location may have specific needs that we do not address Wall amp Ceiling Framing Build wine cellar walls using standard 2x4 or 2x6 construction methods and ceiling joists following the guide lines of local and state codes in your area As a general rule the thicker the walls and the higher the insulation value in your cellar the better it will be at maintaining a consistent temperature Insulation Insulation is REQUIRED wi
27. irements Maintenance Requirements and End User Requirements may at WhisperKOOL sole discretion void this limited warranty 11 No one has any authority to add to or vary the limited warranty on this Product 3 PRODUCT INSTALLATION REQUIREMENTS a Prior to installing a WhisperKOOL Product the End User must read the WhisperKOOL Owner s Manual and thereafter the End User must follow the required installation use and maintenance procedures set forth by WhisperKOOL in WhisperKOOL s Owner s Manual The Owner s Manual is shipped with each Product and if another copy is needed replacement copies can be downloaded from WhisperKOOL s website www whisperkool com or by contacting WhisperKOOL directly for a new copy of the Owner s Manual b Itis highly recommended that the End User obtain the assistance of a wine storage professional c Failing to address all of the variables associated with proper installation will cause the Product to operate incorrectly and limit both the Product s ability to cool and the longevity of the Product itself d The limited warranty card should be completed and promptly returned by the End User to WhisperKOOL to ensure limited warranty registration and confirmation of date of purchase e The End User is responsible for all risks and costs of installation of the Product including but not limited to all labor costs as well as cost of any additional parts required for the proper and complete installation of the Produ
28. ith the set point of 55 and a differential of 1 F the unit will turn off The Whis perKOOL Humidity Management WHM is an adjust able feature which allows the customer the conve nience of managing the humidity enhancement of their wine cellar The WHM is one of the many Cus tomer Preference Selection features which allow the customer the ability to fine tune the controls Feature is off from the factory but can be turned on with the FON parameter Anti Short Cycle The Anti Short Cycle ensures that the compressor will remain off for a period of 3 minutes after the unit has reached the set point to allow the pressure in the refrigeration system to equalize prior to starting the compressor Defrost Cycle The Defrost Cycle is a precautionary measure as icing or frosting of the coil does not occur during normal operation The system will go through a defrost cycle when the evaporator temperature reaches 26 Dur ing the defrost cycle the indoor fan will provide air flow across the indoor coil which will evaporate any frost accumulation Page 24 Bottle Probe Failure Protection In the event that a bottle probe should fail the APST Advance Product Safety Technology will automati cally transition the Refrigeration Compressor cycles to a pre determined time series based on detailed laboratory testing which will ensure that the product is kept within the safe range Remote Control Panel optional The control pan
29. ld not be covered in case the unit needs to be removed for servicing 2x4 Upper Support Wall Stud A Mounting Flange Back of unit 2x4 Lower Support S 9 Di i Drain Port J Electrical Outlet Location of Supply and Return Grilles Locate the supply and return grilles inside the cellar to create an airflow pattern that maximizes air circulation in the room Avoid short circulation of the air Do not e Install through the wall return air grilles at floor level as they will collect dust from the floor Mount the unit lower than 18 from the ceiling e Locate the supply or return air grille where it is blocked by bottles boxes or cases Liquid Measuring Thermostat System To assure a consistent temperature place bottle probe approximately 3 feet away from the air output and not in the flow of the air Page 17 Condensation Drain Line Tube The condensation drain line tube is used to remove excess condensation from the unit to a proper discharge location It is important that the drain line tube is properly connected and used to prevent leakage and other problems associated with excess condensation Failure to use the condensation drain line tube will void the warranty on the unit Drain Line All units come with a drain line for additional removal of excessive condensate It is mandatory to install the drain line attachment During operation the cooling uni
30. le Cellar Pre Chill Button 3 5 Set Button View Set Point 1 Change Set Point 3 5 mo Low Bottle Temp History amp Scroll SET Down CPSM 10 15 a Button 1 Reset Hi amp Lo Button 3 5 Push to see the min stored temperature Display and modify set point In In programming mode use to browse the programming mode it selects a PA codes or decrease parameter confirms an opera the displayed value es Control ON OFF Button ligaltayedio RESET Evap Coil is 26 turns off Turns the Cooling Unit when coil reaches 40 ON OFF Remote Controller Layout XW260K If your unit has a remote keypad then you will have the XW260K controller Note The 1 or 3 5 qualifies the amount of time in seconds that the button must be pushed to activate the feature Refer to page 29 31 for complete instructions Evaporator and Condenser Fan Hi Bottle Temp History amp Scroll Button 1 SLET ere Button 3 5 ush to see the max stored temperature Set Button In programming mode use to browse the View Set Point 1 EG parameter codes or increase the display Change Set Point 3 5 value Hold for 3 seconds to start fast SET Down CPSM 3 5 J ENI AYE Reset Hi amp Lo Button 3 5 Display and modify set point In programming mode it selects a parameter confirms an opera tion Hold for 3 seconds when the min or max temperature is displayed to RESET DIXELL Low Bottle Temp History amp Scroll B
31. les on the mounting bracket with the half shears on the unit depending on the desired mounting location secure using the 1 2 self tapping screws provided Refer to the illustration below for the location of the half shears 7 1 ee 2 Retrofit your current WhisperKOOL cooling unit 3 4 e Back of unit QQ e Front of unit Applying Insulation Tape Locate the four precut pieces of black foam tape included with the system There should be two larger pieces and two smaller pieces Once you have at tached the flange pieces to the unit peel back the white paper adhesive covering and place on the corresponding size of flange The large pieces are applied to the side and the smaller pieces to the top and bottom This foam creates a tight seal between the flange and the wall Page 16 PT EXPL5000 060311 Placement of Unit Slide the unit from the outside wall into your wine cellar with the outer flange flush to the wall Secure the flange to the wall through the pre drilled holes The screws should penetrate the studs as well as the upper and lower supports to provide adequate support for the WhisperKOOL system see illustration Seal all cracks and gaps around the WhisperKOOL Extreme unit with an air tight sealant or caulking to prevent air leakage Note If you use decorative molding it should be attached to the walls and never to the cooling unit itself Note The screws to the flange shou
32. of the unit to be ducted Duct the cold air through a vent into the cellar duct the hot exhaust air out of the home This plenum allows for total installation flexibility Accessories can be purchase at www whisperkool com Page 36 PT EXPL5000 060311 INSTALLATION TERMS AND CONDITIONS WhisperKOOL Cooling System WHISPERKOOL PRODUCT BASE TERMS WhisperKOOL Corporation WhisperKOOL is in the business of manufacturing and selling wine cabinets cooling units and related goods each such wine cabinet cooling unit and related good is referred to herein as a Product As used herein the term WhisperKOOL includes any Product sold under the names WhisperKOOL Vinotheque and CellarCool Purchaser means the original purchaser of a WhisperKOOL Product End User means the consumer who has installed and is actually using a WhisperKOOL Product Every sale of a Product from WhisperKOOL to a Purchaser is made subject to these Terms and Conditions of Sale Terms and Conditions Product prices are specified in the WhisperKOOL published price list that is current at the time WhisperKOOL receives Purchaser s particular order Prices are subject to change at any time prior to WhisperKOOL s acceptance of Purchaser s particular order No contract of sale exists until WhisperKOOL has accepted Purchaser s order and provided Purchaser with a written acknowledgment of Purchaser s order Prices are exclusive of and Purchaser shall pay all taxes
33. ontal line parallel to the first one Mark the horizontal lines with a level Using a saw cut along the uppermost horizontal line until your saw reaches the stud Turn the saw around inserting it into the cut you have just made and cut toward the opposite stud so that you have a clean hori zontal cut between the two studs Be careful not to cut into the studs themselves Now make the second horizontal cut from stud to stud on the line 16 1 4 below the first cut Page 13 Once the horizontal lines have been cut make verti N cal cuts using the inside edge of the studs as a guide Once you have made both vertical cuts you should have a rectangular hole in the sheetrock Now you have to make the same hole on the other side of the wall Since you already have one hole this is an easy process Using a nail mark all four corners of the first hole by making nail holes through the sheetrock Then on the other side of the wall connect the holes with a pencil mark and cut Sheetrock alone cannot support the weight of a 96 pound or more cooling system Therefore it is necessary to frame the hole that you have just cut with upper and lower supports Using two 2x4s at 14 5 in length and eight 6d nails secure the upper and lower supports to the right and left studs just inside the sheetrock Make sure that the internal height remains at 16 1 4 so that the Whis perKOOL system will fit snugly through the framed
34. ou will access the Customer Preference Selection Mode CPSM The CPSM allows the customer to Fine Tune the Control Operating System to their applicable choice Press the Set and the Down Arrow buttons simultaneously for 3 5 seconds and you will access the Customer Preference Selection Mode CPSM The CPSM allows the customer to Fine Tune the Control Operating System to their applicable choice The following CPSM options are available for adjustment Fon Humidity Management Enhancement This parameter is normally set at 0 which should provide adequate relative humidity for the cellar An increase in this parameter will increase the Humidity Enhancement RH and a decrease in the parameter will decrease Humidity Enhancement RH Adjustments should be made in increments of 5 with a maximum of 15 and a minimum of 0 After any adjustment to Humidity Enhancement you should wait a minimum of three days before making any additional adjustments This will allow the cellar suf ficient time to acclimate to the new setting Fof Humidity Management Enhancement This parameter is normally set at 15 This parameter should not be adjusted as it simply provides an OFF cycle time for the fan during the compressor OFF cycle However the parameter is located within the CPSM as a convenience to the customer should it need to be adjusted PT EXPL5000 060311 CCT Cellar Pre Chill Duration This parameter is set
35. r Unobstructed Airflow Unobstructed airflow to and from the unit is a critical factor in the unit s overall performance Make sure there is a three foot clearance in the front of the unit as fans blow straight out and should not be obstructed by racking This will assure that the unit can move the air around in an efficient manner Avoid the attempt to camou flage the unit by installing racking in front of the unit This will restrict airflow and thus the unit s ability to work efficiently Exhaust Front of Unit Page 11 Ventilation The necessity of dissipating heat away from the unit is critical to the unit s performance and cannot be over stated As the unit operates and cools a greater amount of heat is generated on the exhaust side of the unit Adequate ventilation is required in order to dissipate heat away from the unit If ventilation is inadequate the exhaust will heat up the area or room and adversely affect the unit s ability to cool In some cases it may be ad visable to install a vent fan to dissipate heat within the exhaust area on the backside of the unit However you must have a fresh air inlet as well If your unit requires ducting please contact WhisperKOOL Customer Service to obtain a specially designed ducting accessory kit for the unit Using any other ducting system will void the warranty Ambient Temperature Factor The cooling system has the ability to cool a wine cellar effici
36. r A Receptacle Receptacle O ETO O L O 15 Amp Circuit Breaker BRAN Evap WHITE RED Fan GREY BLACK a d oe es 2 10 J 30 Crankcase Heater BLUE PT EXPL5000 060311 Page 32 MAINTENANCE SCHEDULE Monthly 1 Check filters 2 Check for unusual noise or vibration 3 Check the drainline to see if it is above the waterline if draining into a vessel Quarterly Clean filters 1 Remove grille ducting on both ends of unit 2 Remove the filter covering the coil 3 Wash with warm water 4 Dry off filter by shaking excess water from filter 5 Open access door and add chlorine tablets to drip tray Annually 1 Replace filters if worn or plugged beyond cleaning 2 Use a vacuum with brush attachment to clean coils Be careful not to crush coil fins when cleaning 3 Inspect for corrosion 4 Check wiring connections and integrity of cords 5 Examine duct work for cracks or possible leaks 6 Pour a 50 50 bleach solution into the drainline every spring Page 33 TROUBLESHOOTING GUIDE Possible Cause Solution oS Evaporator filter and or coil are dirty Clean filter and coil with a vacuum If coil is very dirty use a small hand spray with a small amount of liquid dish washer detergent Spray coil let set for 5 min then flush with fresh water There is something blocking the supply and or return air Remove blockage The evaporator fan is not turning on Call a service tech to t
37. roubleshoot The temperature of the room the unit is exhausting to has dropped below 45 Raise the temperature of the exhaust room The unit has not gone through its defrost sequence yet Check for ice in the depth of the coil Melt with blow drier until coil is warm to the touch Soak up water with a towel If unit continues to ice Possible Cause Observe ice formation pattern If only part way up the coil face unit could be low on refrigerant If so call Customer Service at 800 343 9463 Solution Unit is not plugged in Make sure the unit is plugged into an outlet Power switch not on Turn unit on by pressing the power button on the control No power to outlet Line voltage is incorrect rating for unit Possible Cause Reset circuit breaker on unit by pushing reset button located on right side of unit next to the plug outlet Check line voltage to make sure there is 110v 120v Lower set point Lower set point See page 15 for correct switch position Call Customer Service at 800 343 9463 Solution The temperature or the room unit is exhausting to has exceeded 110 Intake temperature needs to drop below 110 The unit is undersized for the cellar Order correct size unit There is something blocking the supply and or return air on evaporator or condenser side of the unit Remove air flow obstruction Unit is mounted too low in the cellar Re Locate unit so the dist
38. s 35dBA UNIT SPECIFICATION Model 5000ti amp 5000tiR Cellar Size 1000 cu ft Dimensions 14 25 W x 16 H x 28 D Weight 96 Ibs AMPS running 9 dBA 54 low 60 med 68 high Installation Through the Wall partially ducted fully ducted Thermostat Standard Unit Dixell XR70CX Remote Version Dixell XW260K 55 temperature differential Temp Del er Emp Pelle maintains proper cellar temperature when exhaust environment does not exceed 110 F Can be done if the outside temperature does not exceed 110 F the external grille Outside Venting i cover is required Ducting Options Unit can be fully ducted Warranty 2 year parts and labor 5 year compressor Page 6 PT EXPL5000 060311 INTRODUCTION Customer Service Thank you for purchasing a WhisperKOOL Extreme Series cooling unit We strive to provide the highest quality prod ucts and the best possible customer service If you have any questions about your WhisperKOOL unit please call us at 1 800 343 9463 Using the Manual This User s Manual is intended to assist in the proper installation and maintenance of the WhisperKOOL Extreme cooling system In order to ensure the longevity of your cooling unit the equipment should be installed properly and have a proper care and maintenance schedule Please read and review this manual carefully and keep it for future reference What Is the WhisperKOOL Extreme Series Cooling System The WhisperKOOL E
39. s until the set point is displayed and the F symbol starts blinking Next press the UP or Down arrows to change the Set Point Next press the Set button once and the Set Point numbers and the F on the display will blink to confirm the new Set Point setting Press and hold the Set button during the display of the Hi Low Temperature Data History hold button unit rst blinks on display and it will erase the past recorded data file and start recording from the current time and temperature Press the Set and the Down Arrow buttons simultaneously for 10 15 seconds and you will access the Customer Preference Selection Mode CPSM The CPSM allows the customer to Fine Tune the Control Operating System to their applicable choice Press the Set and the Down Arrow buttons simultaneously for 10 15 seconds and you will access the Customer Preference Selection Mode CPSM The CPSM allows the customer to Fine Tune the Control Operating System to their applicable choice The following CPSM options are available for adjustment Fon Humidity Management Enhancement This parameter is normally set at 0 which should provide adequate relative humidity for the cellar An increase in this parameter will increase the Humidity Enhancement RH and a decrease in the parameter will decrease Humidity Enhancement RH Adjustments should be made in increments of 5 with a maximum o
40. stomer Warranty Registration PLEASE COMPLETE AND RETURN THE WARRANTY CARD UPON RECEIPT OF THE UNIT By completing the Product Registration Card you will be confirmed in our customer database ensuring that your information is on file to help you obtain efficient warranty service Please refer to pages 37 39 for complete terms and conditions warranty guidelines and policy for your Whis perKOOL Extreme Series cooling unit Receiving and Inspecting the Unit e Lift only at the designated handhold locations on the shipping container or fully support the unit from underneath A shipment may include one or more boxes containing accessories Before opening the container inspect the packaging for any obvious signs of damage or mishandling Write any discrepancy or visual damage on the Bill of Lading before signing Place the box containing the WhisperKOOL unit on a tabletop to prepare it for testing prior to installing e Sit upright for 24 hours Note WhisperKOOL Extreme units are manufactured in the USA and tested prior to shipment Review the Packing Slip to Verify Contents e Check the model number to ensure it is correct e Check that all factory options ordered are listed If any items listed on the packing slip do not match your order information contact WhisperKOOL Customer Service immediately Check the Box for the following contents Mounting Bracket 14 14 2 Mounting Bracket 15 34 2 Accessory Kit One e WhisperKOO
41. t undersized Call Customer Service at 800 343 9463 Compressor is overheated Shut unit off for 1 hour to allow compressor to cool Turn back on and check for cooler air flow out If compressor runs check for and clean condenser coil as possible cause of compressor overheating If problem repeats call cus tomer service Possible Cause Compressor and or starting components faulty Call Customer Service at 800 343 9463 Compressor may have overheated Shut unit off for 1 hour to allow compressor to cool Turn back on and check for cooler air flow out If compressor runs check for and clean condenser coil as possible cause of compressor overheating If problem repeats call cus tomer service Possible Cause Solution Faulty fan motor Call Customer Service at 800 343 9463 Faulty fan relay Call Customer Service at 800 343 9463 Possible Cause Solution Evaporator blows on bottle probe Move bottle probe to a more central location Unit low on refrigerant charge Call Customer Service at 800 343 9463 Condensing fan motor capacitor faulty Call Customer Service at 800 343 9463 Compressor and or starting components faulty Call Customer Service at 800 343 9463 Possible Cause Solution Not enough moisture Raise the Fon setting to increase the humidity level Page 35 TECHNICAL ASSISTANCE WhisperKOOL Customer Service is available Monday through Friday from 8 00 a m to 4 00 p m Pacific Time The customer service
42. t will strip excess water from the air in order to maintain the proper level of humidity within the cellar However in extreme humidity additional condensate will be removed Thus the drain line will prevent overflow and leaking by allowing for discharge of the additional condensate Drain Li y LEMS AN Failure to install the drain line voids warranty o C e T Fitting To prevent mold from growing allow the drainline to hang above the water line WRONG Drainline is under water Page 18 PT EXPL5000 060311 INSTALLATION OPTIONS Exterior Grille Installation The exterior grille is required on all installations where the condenser side of the unit is exposed to the outside of the dwelling i e rain and weather STEP 1 Now determine at what depth the unit will be installed e Foranon flush installation i e holes location 42 WhisperKOOL retrofit or 1 Middle Wall or 3 place the grille on the condenser end and line up the holes on the grille with the holes on unit location 4 Use the 8 self tapping screws provided to fasten the grille to the unit e Fora flush installation place the grille on the condenser side and then place the mounting bracket over the grille sides stacking them Align the holes and fasten with the 8 self tapping screws provided Itis required to use self tapping screws provided Do not drill screws into unit
43. tem ON or OFF from the control panel This feature does not disconnect power from the unit In order for the power to be shut off from the unit the power cord must be unplugged from the wall receptacle Press the ON OFF button once for button application Up and Down Use these buttons to scroll up or down the CPSM Customer Preference Selection Arrows Mode menu Displays the Highest and Lowest temperature sensed by the Bottle Probe This feature allows the customer instant access to the recorded data applicable to the Bottle Probe Temperatures it can be easily reset to reflect current temperatures Press the UP arrow or the Down arrow once and the Highest or Lowest Tempera ture Hi Lo sensed by the Bottle Probe will be displayed To reset the Hi Lo press and hold the Set button when the Hi Lo value is displayed on the Digital Display continue to hold the Set button until rst appears on the digital display and then blinks This will erase the past recorded Temperature Data History and start recording from the current time and temperature forward Tem peratures displayed would reflect Bottle Probe Temperatures from that point in time and beyond The Hi Lo feature should be reset at initial Start Up and after the Cellar or Cabinet has obtained normal operating temperatures which is generally 55 F Cellar PreChill CPC The CPC Feature is activated by pressing the Up button for 3 5 secon
44. th the use of the WhisperKOOL product Standard fiberglass or rigid foam insulation is normally used in cellar construction or in some cases blown in insulation is used It is very important that all walls and ceilings are insulated to keep the cellar temperature as consistent as possible during the summer and winter months The R value or quality of insulation is determined by the rate at which heat passes through the insulation The higher the R value the more resistant the insulation is to conducting heat Using higher R values in insulation will lower your operating costs and unit run time Vapor Barrier Vapor Barrier is REQUIRED to prevent the intrusion of water vapor so that the cellar can be kept at the correct temperature and humidity 6 mm plastic sheeting recommended should be applied to the warm side of the cellar walls The vapor barrier must also be applied to the outside walls and ceiling Ifit is impossible to reach the outside then the plastic must be applied from within the cellar The most common method is to wrap the entire interior leaving the plastic loose in the stud cavity so the insulation can be placed between each stud All of the walls and ceiling must be wrapped in plastic for a complete vapor barrier In areas of high humidity such as Southern and Gulf States the vapor barrier will prevent infiltration of warm moist air The moist air can cause mold to form and standing water in drain pans promote microbial and
45. that the Product they are purchasing is suitable for their particular needs and requirements and thus no responsibility will be placed with WhisperKOOL for the End User s decisions in this regard Page 38 PT EXPL5000 060311 b It is the End User s responsibility to secure safe haven storage for ANY AND ALL items that are being kept and stored in the End User s wine cellar including any Product WhisperKOOL takes no responsibility for the safety and preservation of the aforementioned items in the event that the environment becomes unsuitable to maintain a proper storage environment 6 SALES AND USE TAX WhisperKOOL only collects California sales tax for orders shipped within the State of California WhisperKOOL does not collect sales tax for orders shipped to other states However the Purchaser and the End User may be liable to the taxing authority in their state for sales tax and or use tax on the Product The Purchaser and the End User should each check with their state s taxing authority for sales and use tax regulations 7 CUSTOMER SERVICE AND TROUBLESHOOTING WhisperKOOL s customer service department is available to answer and questions or inquiries for End Users regarding a WhisperKOOL Product as well as to assist in performing basic troubleshooting Monday through Friday from 8 00 a m to 4 00 p m PST at telephone number 1 800 343 9463 WhisperKOOL Corporation is located at 1738 East Alpine Avenue Stockton California 95205 8 AD
46. uide oooooooomommmomo 5 Fan Speed Reference anananananunnnannenenenenenenenene 6 INEFOGUCUION cit AA A A ds 7 Receiving amp Inspecting The Unit c c ccc ccc cecs 8 Quick Start Guide css sessar 244 240 eee eas bees eae 9 Preparing the Wine Cellar o oooooooommmocrrm carcs 10 Installation ci ai ae Oe oe 15 Through The Wall Installation ooooooooomo 16 Installation Options cece cece ccc cece ence ences 19 Liquid Measuring Thermostat SystemM 20 Remote Controller 0 cece cece cece cence ence ence ences 21 Multi Speed Control 0 ce cece cece cence ence e een en ees 23 System Operation Standard and Remote 24 Standard Control Functions 0 cece cece eee cece ees 25 Standard Wire Schematic 0 cece eee eee nee e eee ees 28 Remote Controller Functions 0c cece eee eee ences 29 Remote Wire Schematic ccc ccc cece e eee e tence ences 32 Maintenance SchedUle cece cece een e eee ees 33 Troubleshooting Guide ccc ccc ccc ccacae aers 34 Technical Assistance Qo c occcecrcerre 36 Accessories for Cooling Unit ca ccc e cese ce cae 36 Installation Terms and Conditions 37 We manufacture test and certify 100 of our wine cooling units in the USA By sourcing the
47. ure allows the customer instant access to the recorded data applicable to the Bottle Probe Temperatures it can be easily reset to reflect current temperatures Press the UP arrow or the Down arrow once and the Highest or Lowest Tempera ture Hi Lo sensed by the Bottle Probe will be displayed To reset the Hi Lo press and hold the Set button when the Hi Lo value is displayed on the Digital Display continue to hold the Set button until rst appears on the digital display and then blinks This will erase the past recorded Temperature Data History and start recording from the current time and temperature forward Tem peratures displayed would reflect Bottle Probe Temperatures from that point in time and beyond The Hi Lo feature should be reset at initial Start Up and after the Cellar or Cabinet has obtained normal operating temperatures which is generally 55 F Cellar PreChill CPC The CPC Feature is activated by pressing the Up button for 3 5 seconds and the CPC logo will be displayed on the digital display The CPC feature can be terminated by pressing the Up button for 3 5 seconds or the feature will self terminate after 6 hrs 1 The CPC Feature may be used to Pre Chill the Cellar prior to loading it with Warm Product The feature will shift the Set Point down to a lower setting of 52 F for the next 6 hours After the 6 hour time period the Set Point will automatically return to th
48. utton 1 Push to see the min stored temperature In programming mode use to browse the parameter codes or decrease ALARM Pre Chill Display thedispiayed value Control ON OFF Button Turns the Cooling Unit ON OFF Page 5 FAN SPEED REFERENCE Extreme 5000ti or 5000tiR Your fan speed selection will depend on the amount of heat that needs to be removed from the cellar as well as the application of the unit Thru the Wall Installation or Ducted If the unit is going to be ducted you would need to use the highest fan speed The higher fan speed is designed to support the reduction in airflow created by the ductwork For the thru the wall application the fan speed selection will depend on the cellar size insula tion factor door seal and desired wine temperature When initially installing the unit set the fan speed to the highest setting for a quick chill down Once the temperature of the cellar reaches the desired temperature you may be able to select a lower fan speed to handle the normal load In the event the temperature outside goes above 90 degrees when exhausting to the outside you may need to select the higher fan speed DBA Evaporator Condenser 51 51 Medium High To get a feeling for decibels a food blender at 3ft is 90 dBA garbage disposal at 3ft is 85 dBA vacuum cleaner at 10ft is 75 dBA normal speech at 3ft is 79 dBA dishwasher in the next room is 55dBA Quiet night i
49. witch to rear if you would like to plug the unit into a socket inside of the cellar set the selector switch to the front position When placed in either position power can only enter the unit utilizing the power inlet you ve selected Plug your WhisperKOOL unit into a surge protector or power conditioner As with any sensitive electrical equip ment the WhisperKOOL electrical equipment may be damaged by power surges and spikes Power surges and spikes are not covered in the WhisperKOOL Extreme warranty WE RECOMMEND THAT YOU DO NOT USE A GROUND FAULT INTERRUPTER GFI WITH THIS PRODUCT In case the unit should lose power press the reset button and attempt to turn the unit back on Check the home main circuit breaker If the unit does not respond properly refer to the Troubleshooting section on page 34 Manual Reset Front Rear Power Switch Front Power Inlet Page 15 THROUGH THE WALL INSTALLATION without ductwork Mounting Bracket Installation There are four individual mounting brackets one for each side of the unit There will be two long brackets and two short brackets upon receiving the unit these brackets will be located on top of the packaging foam on top of the unit These brackets are designed to mount toward the rear of the unit and mount to the exterior side of the cellar wall On each panel of the unit there are two half shears for each bracket and four different locations for mounting the brackets Align the ho
50. xtreme Series system is a specialized refrigeration unit designed for one purpose only to main tain the optimal temperature and humidity levels conducive to the proper storage and aging of fine wines It is a self contained cooling unit designed to be used as a forced air through the wall unit or as a remote mount unit with external ductwork connections How Does the WhisperKOOL Extreme Series Work The WhisperKOOL Extreme Series cooling system is especially designed for the use and application to maintain opti mal conditions for wine storage and aging The system is fully self contained and can be installed as a Thru The Wall application or the unit is capable of an even more flexible Ducted application which allows the unit to be placed in an indoor remote site resulting in a quiet airflow The standard Through the Wall and ducted units are temperature controlled via a bottle probe and the ducted system comes standard with a remote key board that can be located up to 50 ft from the cooling system Note Remote Unit comes standard with a 50 ft bottle probe and 50 ft of cable for the remote keypad additional lengths are optional Temperature Setting The WhisperKOOL Extreme unit can be set at any temperature within the acceptable wine aging range of 50 F to 67 F It is designed to cool up to 55 F cooler than the ambient temperature of the space to which it is exhausting Page 7 RECEIVING amp INSPECTING THE UNIT Cu