Home
Whirlpool SC864OED User's Manual
Contents
1. Use and Care Guide If you need assistance The Whirlpool Consumer Assistance Center will answer any questions about operating or maintaining your cooktop not covered in the Installation Instructions The Whirlpool Consumer Assistance Center is open 24 hours a day 7 days a week Just dial 800 253 1301 the call is free When you call you will need the cooktop model number and serial number Both numbers can be found on the model serial rating plate located on the underside of the cooktop burner box lt gt iflpdol CORPORATION Prepared by Whirlpool Corporation Benton Harbor Michigan 49022 If you need service In the event that your Whirlpool appliance should need service call the dealer from whom you purchased the appliance or a Whirlpool authorized service company A Whirlpool authorized service company is listed in the Yellow Pages of your telephone directory under Appliances Household Major Service or Repair You can also obtain the service company s name and telephone number by dialing free within the continental United States the Whirlpool Consumer Assistance Center telephone number 1 800 253 1301 A special operator will tell you the name and number of your nearest Whirlpool authorized service company Maintain the quality built into your Whirlpool appliance call a Whirlpool authorized service company Care cleaning and maintenance If removing the cooktop is ne
2. control knob is turned to the desired setting O wa OO OO OFF Q K2 NN 14 1 2 m Check the operation of the cooktop burners Push in and turn each control knob to LITE position The flame should light within 4 seconds Do Not leave the knob in the LITE position after burner lights If burners do not light properly turn control knob to the OFF position Check that burner cap is in the proper position Check that power supply cord is plugged in and that circuit breaker or house fuse has not blown Check that the shutoff valve is in the ON position Check operation again If a burner does not light at this point contact your Whirlpool dealer for assistance 1 3 m Push in and turn each control knob to the LO or simmer setting The LO setting of each burner has been factory set to the lowest setting available to provide reliable reignition of the burner If it does not stay lit on the LO setting check LO setting as follows a Turn control to LITE until burner ignites b Quickly turn knob down to LOWEST POSITION C If burner goes out readjust valve as follows Remove the surface burner control knob Insert a flat blade screwdriver into the hollow valve stem and engage the slotted screw inside Flame size can be increased or decreased with the turn of the screw Adjust flame until you can quickly turn knob from LITE to LOWEST POSITION without extinguishing t
3. separate circuit serving only this appliance be provided Electronic ignition systems operate within wide voltage limits but proper grounding and polarity are necessary In addition to checking that the outlet provides 120 volt power and is correctly grounded the outlet must be checked by a qualified electrician to see if it is wired with correct polarity A wiring diagram is provided in the literature package Recommended grounding method For your personal safety this appliance must be grounded This appliance is equipped with a 3 prong grounding plug To minimize possible shock hazard the cord must be plugged into a mating 3 prong grounding type wall receptacle grounded in accordance with the National Electrical Code ANSI NFPA 70 latest edition and local codes and ordinances See Figure 1 If a mating wall receptacle is not available it is the personal responsibility and obligation of the customer to have a properly grounded 3 prong wall receptacle installed by a qualified electrician Sprong grounding type wall receptacle grounding prong power supply cord Figure 1 Now start With cooktop in kitchen 2 m Remove pressure regulator hardware package burner grates and caps package from shipping box Lift entire cooktop up from cutout when repositioning cooktop in countertop opening to prevent scratching countertop 3 m Insert cooktop into countertop cutout Center cooktop in cutout Ch
4. Installation Instructions IMPORTANT Read and save these instructions IMPORTANT Installer Leave Installation Instructions with the homeowner Homeowner Keep Installation Instructions for future reference Save Installation Instructions for local electrical inspector s use Note This cooktop is manufactured for use with Natural gas To convert for use with L P Propane gas requires Kit No 4173631 for use with model SC8640ED series only available from your Whirlpool dealer or authorized parts distributor Part No 3189404 Rev A 30 Sealed Burner Cooktop This cooktop is not approved for Before you start use with downdraft vent systems Proper installation is your responsibility Make sure you Check location where cooktop have everything necessary for correct installation It isthe will be installed The location responsibility of the installer to comply with the installation should be away from strong draft clearances specified on the model serial rating plate The areas such as windows doors and model serial rating plate can be found on the underside strong heating vents or fans The of the cooktop burner box Write down your cooktop cooktop should be located for model and serial numbers before installing cooktop You convenient use in the kitchen will be asked for these numbers if you need to call for service or assistance Note This cooktop is manufactured for use with Natural gas To conve
5. cessary for cleaning or maintenance shut off gas supply Disconnect the gas and electric supply Remove the mounting bracket on the right and left side of burner box After disconnecting the gas and electric supply finish removing the unit for servicing and cleaning Reinstall in reverse order and check gas connection for leaks Printed in U S A
6. eck that front edge of cooktop is parallel to front edge of countertop Check that all required clearances are met and that cooktop is properly positioned Copies of the standards listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 American Gas Association 1515 Wilson Boulevard Arlington Virginia 22209 Numbers correspond to steps Do Not overtighten screws Overtightening screws could damage cooktop surface cooktop countertop 2 1 2 clamping screw clamping bracket mountin 5 16 clamp bracket bracket screw 4 m Rotate mounting brackets away from burner box Tighten the mounting brackets to the burner box Insert the 2 1 2 clamping screws into the mounting brackets Use a screwdriver to tighten screws against the underside of countertop 5 m Install the pressure regulator with the arrow on the regulator pointing up toward unit and in a position where you can reach the access cap A WARNING Fire Hazard Do Not make connection too tight The regulator is die cast Overtightening may crack regulator resulting in a gas leak and possible fire or explosion nipple flexible metal tubing 3 8 nipple 7 mT 7 AE TTT wE 3 8 adapters manual shutoff valve pressure regulator All connections must be wrench tightened 6 m Assemble the flexible metal tubing from the gas supply pipe to the pressure regulat
7. ers j adjustable wrench tape measure ruler Gas supply requirements Observe all governing codes and ordinances A WARNING HW f Fire Hazard Cooktop must be connected to a regulated gas supply Do Not use an open flame to test for leaks from gas connections New A G A design certified flexible gas line should be used when codes permit Failure to follow these instructions could result in a fire explosion or personal injury A This installation must conform with local codes and ordinances In the absence of local codes installations must conform with American National Standard National Fuel Gas Code ANSI 2223 1 latest edition B m Input ratings shown on the serial rating plate are for elevations up to 2 000 feet For elevations above 2 000 feet ratings are reduced at a rate of 4 for each 1 000 feet above sea level C m The sealed gas cooktop is manufactured for use with NATURAL gas Conversion to L P gas can be made with Kit No 4173631 available from your Whirlpool dealer or authorized parts distributor No attempt shall be made to convert the appliance from the gas specified on the model serial rating plate for use with a different gas without consulting the servicing gas supplier Conversion must be done by a qualified service technician using only the kit number specified D Provide a gas supply line of 3 4 rigid pipe to the cooktop location A smaller size pipe on long runs
8. he flame Flame should be as small as possible without going out You have just finished installing your new Whirlpool cooktop To get the most efficient use from your new cooktop read your Whirlpool Use amp Care Guide Keep Installation Congratulations Instructions and Guide close to cooktop for easy reference The instructions will make reinstalling your Whirlpool cooktop in another home as easy as the first installation Wiring diagram THE POWER CORD ON THIS APPLIANCE IS EQUIPPED WITH A THREE PRONGE ADT ROUNDING PLUG WHICH MATES WITH STANDARD THREE PRONGED GROUNDING WALL RECEPTACLES PLUG POWER 1 4 WIDE BLADE NEUTRAL 5 6 WIDE BLADE GROUND ROUND BLADE CONNECTOR 250 TERMINALS BLK VALVE as 2 SWITCHES i SWITCHES ON VALVES eee nUe ah oe oe PLETE CIRCUIT OSED WHEN KNOB IS ESINEN DS Anae IGNITOR FROM OPF ELECTRODES t a a ae MODEL NO SC8630 SC8640 A WARNING Electrical Shock Hazard Disconnect from electric supply before servicing Replace all panels before operating 120 VAC 60 HERTZ PHASE 15 OR 20 AMP Part No 3189404 Rev A 1996 Whirlpool Corporation If cooktop does not operate Check that the circuit breaker is not tripped or house fuse blown Check that power supply cord is plugged into wall receptacle Check that gas valves are turned to the ON position A more detailed troubleshooting checklist is provided in the
9. l cooktop to countertop covered with not less than No 28 MSG sheet steel 0 015 stainless steel 0 024 aluminum or 0 020 copper 36 min clearance between the top of the cooking platform and the bottom of an unprotected wood or metal sheet TR 1 1 2 from SL fear wall See Note for minimum clearances Minimum distance to nearest combustible surface above cooktop Panel A Depth 21 Grounded electrical outlet is required See Electrical requirements Proper gas supply connection must be available See Gas supply requirements Countertop opening dimensions that are shown must be used Given dimensions provide required 0 clearance Important Observe all governing codes and ordinances Failure to meet codes and ordinances could lead to fire or electrical shock WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death Do Not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS e Do Not try to light any appliance e Do Not touch any electrical switch Do Not use any phone in your building e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions e if you cannot reach your gas supplier call the fire department Installation a
10. may result in insufficient gas supply Pipe joint compounds made for use with NATURAL and L P gas must be used E gw If local codes and ordinances permit A G A design certified flexible metal tubing is recommended for connecting this cooktop to the gas supply line Do Not kink or damage the fiexible tubing when moving the cooktop The pressure regulator has 3 8 female pipe threads You will need to determine the fittings required depending on the size of your gas supply line flexible metal tubing and shutoff valve Panel B shutoff valve open position gas supply line F The supply line shall be equipped with an approved shutoff valve This valve should be located in the same room as the cooktop and should be in a location that allows ease of opening and closing Do Not block access to shutoff valve The valve is for turning on or shutting off gas to the appliance G m f rigid pipe is used as a gas supply line a combination of pipe fittings must be used to obtain an in line connection to the cooktop All strains must be removed from the supply and fuel lines so cooktop will be level and in line H m The regulator must be checked at a minimum 1 inch water column above the set pressure The inlet pressure to the regulator should be as follows for both operation and checking the regulator setting NATURAL GAS Minimum pressure 4 Inches W C l u Line pressure testing Testing above 1 2
11. nd service must be performed by a qualified installer service agency or the gas supplier A WARNING Gh f Fire Hazard Do Not obstruct the flow of combustion and ventilation air Injury Hazard To eliminate the risk of burns or fire avoid installing cabinet storage above the cooking surface if cabinets are already installed reduce the hazard of reaching over a heated cooking surface by installing a range hood The range hood should extend a minimum of 5 inches out from the bottom front of the cabinets Reaching over a heated cooking surface could result in a serious burn or other injury A WARNING A Electrical Shock Hazard it is the customer s responsibility To contact a qualified electrical installer To assure that electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances Failure to do so could result in death or serious injury Take special care when drilling holes into the wall for electrical wiring Electrical wires may be concealed behind the wall covering Failure to do so could result in death or serious injury Copies of the standards listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 American Gas Association 1515 Wilson Boulevard Arlington Virginia 22209 Tools needed for installation t flat blade y screwdriver pli
12. or You will need to determine the fittings required depending on the size of your gas supply line flexible metal tubing and shutoff valve T m Use pipe joint compound made for use with NATURAL and L P gas to seal all gas connections If flexible metal tubing is used be certain tubing is not kinked Panel C gas supply line 8 m Open the shutoff valve in the gas supply line Wait a few minutes for gas to move through the gas line A WARNING CL Fire Hazard Do Not use an open flame to test for leaks from gas connections Checking for leaks with a flame may result in a fire or explosion 9 m Use a brush and liquid detergent to test all gas connections for leaks Bubbles around connections will indicate a leak If a leak appears shut off gas valve controls and adjust connections Then check connections again NEVER TEST FOR GAS LEAKS WITH A MATCH OR OTHER FLAME Clean all detergent solution from cooktop 1 0 m Plug the power supply cord into the grounded outlet burner cap burner base ignitor electrode gas tube opening 1 1 m Put burner caps on each burner base Place burner grates over burner bases and caps Electronic Ignition System initial lighting Cooktop burners use electronic igniters in place of standing pilots When the cooktop control knob is pushed in and turned to the LITE position the system creates a spark to light the burner This sparking Continues until the
13. psi 14 inches W C gauge The cooktop and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than 1 2 psig 3 5kPa Testing at 1 2 psi 14 inches W C gauge or lower The cooktop must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5kPa Electrical requirements A WARNING Electrical Shock Hazard Electrical ground is required on this cooktop Do Not ground to a gas pipe Do Not modify the power supply cord plug If plug will not fit the outlet have a proper outlet installed by a qualified electrician Do Not have a fuse in the neutral or grounding circuit A fuse in the neutral or grounding circuit could result in an electrical shock Do Not use an extension cord with this cooktop Check with a qualified electrician if you are not sure whether the cooktop is properly grounded Failure to follow these instructions could result in death or serious injury If codes permit and a separate grounding wire is used it is recommended that a qualified electrician determine that the grounding path is adequate A 120 volt 60 Hz AC only 15 ampere fused electrical supply is required A time delay fuse or circuit breaker is recommended It is recommended that a
14. rt for use with L P Propane gas requires Kit No 4173631 available from your Whirlpool dealer or authorized parts distributor Product Dimensions ALL OPENINGS IN THE WALL OR FLOOR WHERE THE COOKTOP IS TO BE INSTALLED MUST BE SEALED Burner box helght 2 3 4 30 min base cabinet is required If cabinet has a drawer a 3 depth clearance from the countertop to the top of the drawer or other obstruction in base cabinet is required Cabinet and Cutout Dimensions 30 min cabinet width ed Ce ee above cooktop 1 min space between adjacent cooktops Minimum distance to nearest rear combustible surface depth above cooktop N ae eee pa A 19 1 4 opening depth 18 min clearance upper cabinet to countertop 2 1 4 min space to front 28 1 4 A edge of NO opening width T E Hf l Y Recommended area for 120v grounded outlet Wall gas lino on rear cabinet opening wall 5 below countertop and centered In cabinet Centerline of La wel and unlit Important Observe all I governing codes and j ordinances N Failure to meet codes and ordinances could lead to fire or electric Centerline N N of floor N vf N XN Note 30 min when bottom of wood or metal cabinet Is protected by not less than 1 4 N flame retardant mlliboard Do Not pinch the shock power supply cord between the cooktop and cabinet Clearance Dimensions Do Not sea