1. We recommend vents with screens 556 6 6 Access doors to the structure not considered vents 66 666 66 666 66 Clean the vents periodically DANGER Failure to follow recommended minimum venting instructions can cause gas to collect in the structure in the event of a gas leak This may result in a fire or an explosion which can cause serious bodily injury or death and damage to property WWW WEBER COM NOTES ATTENTION This product has been safety tested and is only certified for use a specific country Refer to country designation located on outer carton These parts may be gas carrying or gas burning components Please contact Weber Stephen Products Co Customer Service Department for genuine Weber Stephen Products Co replacement part s information WARNING Do not attempt to make any repair to gas carrying gas burning igniter components or structural components without contacting Weber Stephen Products Co Customer Service Department Your actions if you fail to follow this Product Warning may cause a fire an explosion or structural failure resulting in serious personal injury or death as well as damage to property WEBER STEPHEN PRODUCTS WWW weber Com 2009 The following trademarks are
2. AL WWW WEBER COM ASSEMBLY S 660 BATTERY HOUSING WIRING BLACK WIRE 4 GREEN WIRE RED WIRE om WARNING Make sure that all control knobs are turned to the OFF position before connecting the gas supply and operating the grill WWW WEBER COM ASSEMBLY Requires 3 alkaline batteries Included Use alkaline batteries only Do not mix old and new batteries or different types of batteries standard alkaline or rechargeable Note Secure wire to side panel WWW
3. ASSEMBLV gt a 2 2 At YX 4 The Weber Grill Out Handle Light has a Tilt Sensor Lid up ON Lid Closed OFF The power button a activates or deactivates the Tilt Sensor For daytime use deactivate the sensor by pressing power button a Requires 3 AAA alkaline batteries not included WWW WEBER COM 22 GAS SUPPLV BUILT IN GAS LINE LOCATIONS Note Leave an access in the island structure for gas supplv and regulator service that is not inside the grill structure Note Area should be kept clear of sharp jagged or extremely abrasive surfaces to avoid possible damage to gas supply lines Exercise caution when pulling gas lines through built in structure BUILT IN GAS LINE LOCATIONS 21 660 TOLERANCES 4 3 47 4 3 47 1 8 3 8 120 65 120 65 1 8 3 8mm 61 47 6 1 4 41 8 3 8mm 158 8 mm 158 8 mm 1 8 3 8mm 2 1 2 2 1 2 1 8 3 8mm 63 5 mm 63 5 mm 1 8 3 8mm Plan View Left 3 IB Side View Gas Inlet TYPICAL BULK PROPANE GAS SUPPLY INSTALLATION We recommend that this installation be done by a LICENSED professional GENERAL SPECIFICATIONS FOR PIPING Note Contact your local municipality for building codes regulating outdoor gas grill installations In absence of Local Codes you must conform to the latest edition of the National Fuel Gas Code ANSI
4. area of the island Ventilation openings in the sidewalls of the enclosure should only communicate with the outside of the island structure so that the gas can dissipate outside of the island structure 2 If the remote LP cylinder enclosure has four sides a top and a bottom and is intended for installation in a built in island enclosure 1 At least one ventilation opening a hole or group of holes for the purpose of ventilation needs to be on one side of the enclosure that communicates with the outside of the island structure gas leak should occur or the LP cvlinder should vent in the LP cvlinder enclosure the gas should not be allowed to vent or migrate into the empty or hollow area of the island Ventilation openings should only communicate with the outside of the island structure so that the gas can dissipate outside of the island structure The ventilation opening should be located within 5 inches 127mm of the top of the enclosure and should have a total free area of 20 square inches This relates to 1 square inch of ventilation area per pound of stored fuel 2 At least one ventilation opening a hole or group of holes for the purpose of ventilation needs to be on one side of the enclosure that communicates with the outside of the island structure at the bottom If a gas leak should occur or the LP cylinder should vent in the LP cylinder enclosure the gas should not b
5. 104 95 89 83 79 70 63 58 54 1 1 049 514 353 284 243 215 195 179 167 157 148 131 119 109 102 1 1 4 1 380 1 060 726 583 499 442 400 368 343 322 304 269 244 224 209 1 12 1 610 1 580 1 090 873 747 662 600 552 514 482 455 403 366 336 313 2 2 067 3 050 2 090 1 680 1 440 1 280 1 160 1 060 989 928 877 777 704 648 602 21 2 2 469 4 860 3 340 2 680 2 290 2 030 1 840 1 690 1 580 1 480 1 400 1 240 1 120 1 030 960 3 3 068 8 580 5 900 4 740 4 050 3 590 3 260 3 000 2 790 2 610 2 470 2 190 1 980 1 820 1 700 4 4 026 17 500 12 000 9 660 8 270 7330 6 640 6 110 5 680 5 330 5 040 4 460 4 050 3 720 3 460 2008 National Fire Protection Association Inc and International Approval Services U S Inc All Rights Reserved TEST CONNECTIONS A DANGER All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of the National Fuel Gas Code ANSI Do not use an open flame to check for gas leaks Be sure 2223 1 54 Natural Gas and Propane Installation Code CSA B149 1 or Propane there are no sparks or open flames in the area while you Storage and Handling Code B149 2 or the Standard for Recreational Vehicles ANSI A 119 2 NFPA 1192 and CSA Z240 RV Series Recreational Vehicle Code as applicable check for gas leaks This will result in a fire or explosion which can cause serious bodily injury or death and damage to property WWW WEBER COM 24 GAS SUPPLY TYPICAL 20
6. IE L ii N 000 6 WWW WEBER COM 18 ASSEMBLV WWWMEBER COM ASSEMBLV 23 la 1 i 6 6 66 6 6 600 000 WWW WEBER COM 20 ASSEMBLV WWW WEBER COM
7. LP PROPANE GAS SUPPLY INSTALLATION The remote tank enclosure kit provide with you grill shall be used for installations using a 20 Ib LP cylinder mounted in an island structure The remote tank enclosure shall house the included hose and regulator assembly and gas connections the tank bracket and the fuel scale for connecting a remote mounted LP cylinder to the Summit Built In gas grill The hose and regulator is listed as a required part of the CSA listed Summit Built In gas grill A properly installed tank enclosure meets the requirements for venting tank retention and separation of the LP cylinder from a heat source as outlined in the ANSI Standard for Outdoor Cooking Gas Appliances Z21 58 CSA 1 6 for LP enclosures You need to hire a licensed contractor or licensed plumber and they need to follow the requirements described in the ANSI Standard for Outdoor Cooking Gas Appliances Z21 58 CSA 1 6 for LP enclosures The requirements described in the Standard for Outdoor Cooking Gas Appliances Z21 58 CSA 1 6 are as follows A remote enclosure for an LP gas cylinder shall be ventilated by openings at both the upper and lower levels of the cylinder This shall be accomplished by one of the following A One side of the remote LP cylinder enclosure shall be completely open or B If the remote LP cylinder enclosure is designed to have four sides a top and a bottom ventilation is required for the remote LP cylinder enclosure
8. Lu m 0 lt WWW WEBER COM 21 2 0 lt 2777777 WWW WEBER COM 10 ASSEMBLV CAUTION Use two people to lift and install the Summit Built In frame assembly A Lift the frame assembly into the island structure opening Make sure the frame is resting level on the finished surface of the structure B Adjust the Front Vent to rest squarely on ground X d NNNNN WS A CLEARANCES 1 24 610 mm Anv Surface Grill Frame Note For a countertop treatment Recommended 19 1 mm 3 47 inch overhang Notch front edge for frame to fullv slide in WWWMEBER COM ASSEMBLY 1 4 6 35 mm Drill Bit Cun A Apply a bead of silicone sealant 1 around the perimeter and front edges of the grill that are in contact with the island structure This will prevent moisture seepage The sealant you use must have a temperature rating above 120 F 48 82 C S 660 ATTENTION Before applying any silicone sealant make sure the cookbox is flush with the front of the grill frame
9. WEBER COM 14 ASSEMBLV S 660 o 0 000 O0 ets LA 3 WWW WEBER COM ASSEMBLV 17 loo o 00 000 YOO 8 72 AN Match Holder WWW WEBER COM 16 ASSEMBLV A ATTENTION gt Before drilling holes for the S 1 M 1 4 6 35 mm sure the cookbox 5 Drill Bit is flush with the front of the grill frame WWW WEBER COM ASSEMBLV AQ QEQONONON A M 1 1111 HA HA
10. cylinder from a heat source listed in the ANSI Standard for Outdoor Cooking Gas Appliances ANSI 221 58 CSA 1 6 could be dangerous and could result in a fire or an explosion causing serious bodily injury or death and damage to property If you do not follow the DANGER statements exactly the Warranty on the Summit Built In gas grill will be voided ENCLOSURE CHART LP Tank Enclosure Any Surface Non Combustible Surface CLEARANCE FROM COMBUSTIBLE SURFACES OR STRUCTURES WARNING Clearance from the outside walls of the sides and back of the LP Tank Enclosure must be a minimum of 24 60 96cm any surface Refer to Typical Gas Supply Installation before starting installation WARNING The structure island counter tops and adjacent work areas for the LP Tank Enclosure must be built from noncombustible materials only NOTE If you have questions on what materials are considered noncombustible contact you local building supplier or fire department WWWMEBER COM PARTS LIST ASSEMBLV PARTS LIST Hose and regulator 1 Tank stand 1 Tank stand base 1 Tank Scale 1 1 4 20 nut 6 Nylon washer 12 gt 1 4 20 x 1 2 bolt 6 Cylinder glide 2 2 1 2 Flare Gasket 2 3 8 Flare Gasket 2 WWW WEBER COM 28 ASSEMBLV MOUNTING THE LP TANK BRACKET Mount the LP tank bracket to the right hand side of t
11. registered in the name of Weber Stephen Products Co an Illinois corporation located at 200 East Daniels Road Palatine Illinois 60067 U S A Australia Smokey Joe Weber Kettle Silhouettef Genesis Austria Kettle Silhouettef Smokey Joe Weber Benelux Kettle Silhouettef Smokey Joe Weber Compact Grill Configura tion Botswana Weber Canada Smokey Joe Genesis China Kettle Silhouette Denmark Kettle Silhouette Smokey Joe Weber Finland Smokey Joe France Kettle Silhouettef Smokey Joe Weber One Touch Germany Smokey Joe Weber One Touch Greece Smokey Joe Ireland Kettle Silhouette Smokey Joe Italy Smokey Joe Weber Japan Smokey Joe Weber Korea Smokey Joe Weber New Zealand Weber Smokey Joe Nigeria Weber Norway Smokey Joe Weber Portugal Weber South Africa Smokey Joe Weber Kettle Configuration Spain Smokey Joe Weber Sweden Kettle Silhouettef Smokey Joe Switzerland Kettle Silhouettef Smokey Joe Weber United Kingdom Smokey Joe Weber Weber One Touch U S A Kettle Configuration Kettle Silhouettef Smokey Joe Weber One Touch Firespice Go Anywhere U S A Kettle Configuration Kettle Silhouette Genesis Flavorizer Crossover Flamgo Performer Rapidfire Tuck N Carry Jumbo Joe Bar B Kettle Master Touch Spirit Grill Out Summit Platinum 1 800 Grill Out Ranch Matchless Flame Zimbabwe Weber Kettle Configuration Kettle Silhouette
12. 1 There should be at least two ventilation openings a hole or group of holes for the purpose of ventilation in the sidewalls of the island structure The openings should be located within 5 inches 127mm of the top of the enclosure The ventilation openings should be equally sized and spaced at a minimum of 90 degrees and be unobstructed The openings shall have a total free open area of not less than 20 square inches This relates to 1 square inch of ventilation area per pound of stored fuel capacity Ventilation openings a hole or group of holes for the purpose of ventilation should be provided at floor level The ventilation openings should have a total free area of not less than 10 square inches This relates to 1 2 square inch of ventilation area per pound of stored fuel capacity There should be at least two ventilation openings if the ventilation openings at floor level are in the sidewall The ventilation openings should be within 5 inches 127mm of the floor The ventilation openings should be of equal size and be spaced at a minimum of 90 degrees and should be unobstructed 3 The minimum size of the ventilation hole s should not be less than 1 4 inch 4 The ventilation openings in the sidewalls should not allow venting into the empty or hollow area of the island If a gas leak should occur or the LP cylinder should vent in the LP cylinder enclosure the gas should not be allowed to vent or migrate into the empty or hollow
13. BUTT pair n GAS GRILL Built In LP Gas Grill Installation Guide Tank Enclosure Installation Pg 25 5 460 5 660 43267 VOU MUST READ THIS OWNER S GUIDE A WARNING Follow all leak check procedures BEFORE OPERATING VOUR GAS GRILL carefully in this manual prior to barbecue operation Do this even if the barbecue was dealer assembled DANGER If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flames 3 Open lid 4 If odor continues keep away from the appliance and immediately call your gas THIS GAS APPLIANCE IS DESIGNED FOR supplier or your fire department OUTDOOR USE ONLY Leaking gas may cause a fire or explosion which can cause serious bodily injury or death or damage to property NOTICE TO INSTALLER These instructions must be left with the owner and the owner should keep them for future use WARNING Do not try to light this appliance without reading the Lighting Instructions section of this manual WARNING 1 Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinitv of this or anv other appliance National PROPANE GAS Association CERTIFIED 43267 US 08 06 08 LP DANGER Failure to follow the Dangers Warnings and Cautions contained in this Owner s Manual result in serious bodilv injurv or de
14. Z223 1 NFPA 54 Natural Gas and Propane Installation Code CSA B149 1 or Propane Storage and Handling Code B149 2 or the Standard for Recreational Vehicles ANSI A 119 2 NFPA 1192 and CSA Z240 RV Series Recreational Vehicle Code as applicable e This grill is designed to operate at 11 inches of water column pressure An LP in line regulator mav be necessarv for this pressure A CAUTION If young children are in the area locking valve should be considered e Pipe compound should be used which is resistant to the action of liquid propane gas when gas connections are made e The gas connections must be firmly attached to rigid permanent construction Note The information provided in this manual is general for typical installations We cannot cover all possible installation ideas We recommend prior to installation that you contact your municipality for local building codes and your local fire department for installation verification If you have any questions contact Customer Service at 1 800 446 1071 WWW WEBER COM GAS SUPPLV Table Maximum Capacitv of Metallic Pipe in Cubic Feet of Gas per Hour for Gas Pressures of 2 psi or Less and 6 2 a a Pressure Drop of 0 3 Inch Water Column Based on a 0 60 Specific Gravitv Gas Nominal Actual Length of Pipe Feet Iron Pipe ID Size Inches 10 20 30 40 50 60 70 80 90 100 125 150 175 200 Inches 1 2 622 131 90 72 62 55 50 46 42 40 38 33 30 28 26 3 4 824 273 188 151 129 114
15. ame Rail 1 Rear Panel Assembly 1 Bottom Shelf 1 PARTS LIST Left Door 1 Right Door 1 Warming Rack 1 Right Enclosure Panel 1 Left Enclosure Panel 1 Front Vent Panel 1 Rear Vent 1 Corrugated Gas Line 1 WWW WEBER COM PARTS LIST Flavorizer Bars Stainless Steel Cooking Grates Ea Collection Tray 1 Holder 1 Catch Pan 1 Disposable Drip Pans 2 Battery Housing 1 Right Front Vent Clip 1 Left Front Vent Clip 1 Rotisserie 1 Rotisserie Fork 4 Rotisserie Motor 1 Rotisserie Bracket 1 Handle 2 WWW WEBER COM Smoker 1 Smoker Bar 1 1 2 inch Bolts 20 x 1 2 inch Bolt 10 Nylon Washer 10 Hinge Pin 2 Hair Pin Cotter 2 10 32 x 1 4 inch Steel Screw 5 20 x 1 2 inch Truss Head Screw 2 10 Sheet Metal Screw 3 Flat Head Screw 2 Plastic Anchors 5 Keps Nuts 1 4 x 20 Keps Nut 2 1 inch Bolt 4 20 x 1 inch Bolt 2 Handle Hardware 4 Wire Tie 1 5 2 7 16 inch Wrench 1 6 ASSEMBLV Arrow stickers on Frame Rail 1 and Left Side Panel 2 should point toward each other shown above Door Stop Bracket 3 should be positioned as shown left WWW WEBER COM ASSEMBLY 7 WWW WEBER COM 21 2
16. ath or in a fire or an explosion causing damage to propertv A WARNINGS Do not store a spare or disconnected liquid propane cvlinder under or near the barbecue Improper assembly be dangerous Please carefully follow the assembly instructions in this manual Do not operate the Weber gas barbecue if there is a gas leak present Do not use a flame to check for gas leaks Combustible materials should never be within 24 60 96cm inches of the top bottom back or sides of your Weber gas barbecue Do not put a barbecue cover or anything flammable on or in the storage area under the barbecue Your Weber gas barbecue should never be used by children Accessible parts of the barbecue may be very hot Keep young children away while it is in use You should exercise reasonable care when operating your Weber gas barbecue It will be hot during cooking or cleaning and should never be left unattended or moved while in operation Liquid propane gas is not natural gas The conversion or attempted use of natural gas in a liquid propane unit or liquid propane gas in a natural gas unit is dangerous and will void your warranty not attempt to disconnect any gas fitting while your barbecue is in operation lt lt b b P gt lt BUILT IN CUTOUT DIMENSIONS LOCATING VOUR GRILL When determining a suitable location for your gas grill installation give attention to concerns such as exposur
17. e allowed to vent or migrate into the empty or hollow area of the island Ventilation openings should only communicate with the outside of the island structure so that the gas can dissipate outside of the island structure The ventilation opening should be located within 5 inches 127mm of the bottom of the enclosure and should have a total free area of 10 square inches This relates to 1 4 square inch of ventilation area per pound of stored fuel 3 The minimum size of the ventilation hole s should not be less than 1 4 inch 6 35mm D The remote LP cvlinder enclosure should be constructed with non combustible materials The remote LP cvlinder enclosure should isolate the LP cvlinder from the burner compartment so that it provides shielding from radiation be a flame barrier and provide protection from foreign material such as hot drippings E There should be a minimum of 2 inches 50 8mm between the ground and the floor of the remote LP cvlinder enclosure The LP cylinder valve should be readily accessible for hand operation A door on the remote LP cylinder enclosure to gain access to the LP cylinder valve is acceptable provided it is non locking and can be opened without the use of tools DANGER Use of any other hose and regulator assembly could be dangerous and may not provide adequate gas supply to the Summit Built In gas grill and could result a fire or an explosion causing serious bod
18. e to wind proximity to traffic paths and keeping any gas supply lines as short as possible Never locate the Summit gas grill in a garage breezeway shed under an unprotected overhang or other enclosed area Locate the grill and structure so there is enough room to safely evacuate the area in case of a fire CLEARANCE FROM SURFACES OR STRUCTURES WARNING Clearance from any surface or structure is 24 inches 609 6 mm from the back and sides of the grill Refer to Typical Gas Supply Installation before starting installation WARNING The structure island countertops and adjacent work areas for the built in grill installation must be built from noncombustible materials only NOTE If you have questions on what materials are considered noncombustible contact your local building materials supplier or fire department Keep any electrical supply cord and the fuel supply hose away from any heated surfaces Do not use this Weber tank enclosure kit unless all parts are in place The unit must be properly assembled according to the instructions outlined in the Assembly Instruction section of the Owner s Guide Proposition 65 Warning Handling the brass material on this product exposes you to lead a chemical known to the state of California to cause cancer birth defects or other reproductive harm Wash hands after handling this product LIQUID PROPANE GAS UNITS ONLY Use the regulator that is su
19. he enclosure opening using non corrosive hardware Mounting holes are provided on the sides and bottom of vour LP tank bracket Be sure to mount the bracket securlev to the enclosure before use MOUNTING HARDWARE NOT INCLUDED MOUNTING THE LP HOSE AND REGULATOR Securlev mount the hose and regulator bracket to the top of the built in tank enclosure using non corrosive hardware MOUNTING HARDWARE INCLUDED LP TANK ENCLOSURE GAS LINE LOCATIONS Area should be kept clear of sharp jagged or extremelv abrasive surfaces to avoid possible damage to gas supplv lines Exercise caution when pulling gas lines through built in structure WWW WEBER COM GAS SUPPLV CONNECT GAS SUPPLV 58 inch 147 32 cm corrugated gas line is supplied with the grill This line needs to pass through the gas inlet opening to the main gas supplv 1 Connect the corrugated gas line to the manifold located on the right hand side of grill under the control panel Use the 1 2 flared gasket 1 to ensure proper seal Note 1 2 flared gaskets are included in the Summit Built In tank Enclosure Kit included with vour grill The corrugated line passes through the Island Structure cavity to the hose and regulator connection inside the tank enclosure Shown in illustration 2 Uncap one flare fitting from the 90 Connection on the regulator hose located inside the ta
20. ily injury or death and damage to property DANGER Failure to build a remote LP cylinder enclosure for a 20 Ib cylinder following the requirements for ventilation cylinder retention and separation of the LP cylinder from a heat source listed in the ANSI Standard for Outdoor Cooking Gas Appliances ANSI Z21 58 CSA 1 6 could be dangerous and could result in a fire or an explosion causing serious bodily injury or death and damage to property If you do not follow the DANGER statements exactly the Warranty on the Summit Built In gas grill will be voided WWWMEBER COM BUILT IN TANK ENCLOSURE INSTRUCTIONS OPERATING A WARNING Only use the Weber Tank Enclosure Kit outdoors WARNING Turn off the gas at the LP gas supply cylinder in a well ventilated area Do not use in a garage building when the outdoor cooking gas appliance is not in use breezeway or any other enclosed area WARNING Never store an outdoor cooking gas appliance WARNING Your Weber Tank Enclosure Kit shall not be used under an unprotected combustible roof or overhang WARNING Your Weber Tank Enclosure Kit is not intended to be installed in or on recreational vehicles and or boats A WARNING Keep any electrical supply cord and the fuel indoors unless the LP cylinder is disconnected and removed from the outdoor cooking gas appliance WARNING LP Cylinders must be stored outdoors out of the reach of chi
21. ldren and must not be stored in a building supply hose away from any heated surface garage or any other enclosed area A WARNING Never store an extra spare LP cylinder under or WARNING The LP pressure regulator and hose assembly near the Weber gas barbecue supplied with the Weber Tank Enclosure Kit must be used WARNING Keep the ventilation openings of the cylinder Replacement LP pressure regulators and hoses must be enclosure free and clear of debris obtained from Weber Stephen Product Co WWW WEBER COM BUILT IN TANK ENCLOSURE INSTRUCTIONS ADANGER LOCATING VOUR LP TANK ENCLOSURE When determining a suitable location for vour LP Tank Enclosure Kit installation give Use of other hose and regulator assembly could be attention to concerns such as proximitv to traffic paths and keeping anv gas supplv dangerous and not provide adequate gas supply to Ze SE GE the SE ech 2 1 reezeway shed under an unprotected overhang or other enclosed area Locate the the Summit Built In gas grill and could result in a fire or an Tank Enclosure Kit and structure so there is enough room to safely evacuate the area in explosion causing serious bodily injury or death and damage case of a fire to property DANGER Failure to build a LP cylinder enclosure for a 20 Ib cylinder following the requirements for ventilation cylinder retention and separation of the LP
22. n unit and all other accessory units should be on site before construction begins dimensions have a tolerance of plus or minus inch 6 35 mm The grill frame rests directly on the Island Structure top finished surface Make sure this surface is level Do not support the grill from the bottom If the supporting structure is going to have an electrical outlet for a rotisserie it should be on the left side of the structure BUILT IN CUTOUT DIMENSIONS S 460 S 660 24 minimum 610 mm 24 minimum 610 mm 4 3 4 120 65 mm 4 3 4 120 65 mm 6 1 4 158 75 mm 6 1 4 158 75 mm 10 1 2 266 7 mm minimum 10 1 2 266 7 mm minimum 23 584 2 mm 23 584 2 mm 34 3 8 873 13 mm 34 3 8 873 13 mm 27 685 8 mm minimum distance from front edge of 27 685 8 mm minimum distance from front edge of the cutout for open lid clearance the cutout for open lid clearance 30 1 4 768 35 mm Built In Frame 38 1 4 971 55 mm Built In Frame Note For a countertop treatment Recommended 3 4 19 1 mm overhang Notch front edge for frame to fully slide in Gas Inlet Side Burner Opening Access for electric on left hand side Clearance from any surface or structure is at least 24 609 6mm from the back and sides of the grill or side burner WWW WEBER COM 4 Lid 1 Cookbox 1 Lid 1 Cookbox 1 Front Frame Rail 1 Rear Fr
23. nk enclosure 3 Use the 1 2 12 7 mm inch flared gasket to ensure proper seal NOTE Only use the 3 8 inch 9 53 mm flared gasket if you are installing the optional side burner 4 Connect the corrugated gas line to the 90 Connection CONNECTION CHART a B Typical tank cabinet or tank enclosure location Dae efe RRE es iv 1 2 12 7 mm Flared Gasket Cap Optional Side Burner WWWWERER COM 30 GAS SUPPLV VENTILATION A WARNING Ventillation holes must be provided in the structure at the top and bottom to provide ventilation in the event of gas leak Ventilation holes can be located in a low visibility area and should be protected by screening material to prevent rodents and insects from entering the structure Air holes will also help dry moisture Note These drawings are only a reference Cross ventilation must be incorporated in the supporting structure We recommend a minimum of 100 square inches 254 square cm of venting per side Vents should be on two sides of the structure The above drawings are for reference Location of the vents should be from the center outward Locate the vents at both the bottom of the structure and at the top of the structure The bottom vents should be as close to ground level as possible Make sure the vent area is not blocked interior supports of the structure e
24. pplied with your Weber Tank Enclosure Kit Do not attempt to disconnect the gas regulator or any gas fitting while your barbecue is in operation Adented or rusty liquid propane cylinder may be hazardous and should be checked by your liquid propane supplier Do not use a liquid propane cylinder with a damaged valve Although your liquid propane cylinder may appear to be empty gas may still be present and the cylinder should be transported and stored accordingly f you see smell or hear the hiss of escaping gas from the liquid propane cylinder 1 Move away from liquid propane cylinder 2 Do not attempt to correct the problem yourself 3 Call your fire department CLEARANCES LI 24 inches 610 mm Any Surface 2 277 inches 685 8 mm min for lid clearance Grill Frame Note For a countertop treatment Recommended 3 47 19 1 overhang Notch front edge for frame to fully slide in WWWMEBER COM BUILT IN CUTOUT DIMENSIONS 3 BUILT IN STRUCTURE CUTOUT DIMENSIONS ALL DIMENSIONS ARE TO FINISHED SURFACES EUHEISINICUTOSHIDIMENSIONS WARNING All countertop finished surfaces must be 5 4607 5 6607 s constructed of a noncombustible material 30 1 4 768 35 mm 38 1 971 55 mm 7 1 6 35mm 34 3 4 873 13 mm 343 873 13 mm n 6 35mm 237 584 2 237 584 2 114 6 35mm GENERAL CONSTRUCTION DETAILS Summit Built I