Home
VIZIO IR-200BC User's Manual
Contents
1. Confirm that the power indicator is lit Step 4 Turn off the power of the infrared wireless microphone to be charged then insert the 2 IR 200BT rechargeable batteries into the microphone For proper battery insertion refer to the instruction manual enclosed with the infrared wireless microphone Note Charging cannot be correctly performed if the infrared wireless microphone s power switch is set to the ON position Step 5 Insert the infrared wireless microphone fully into B the charger s microphone receptacle and confirm Removing the mounting adapter that the charging indicator red is lit For the IR 200M microphone p Leave the mounting adapter attached Mounting adapter Insert the microphone into the hole in the adapter to charge For the IR 300M microphone Remove the mounting adapter to charge Refer to the figure at right Charging takes approximately 3 hours after which Pull up the adapter holding down this part the full charge indicator lights green another on the opposite side V es Step 6 Turn off the charger s power once charging is complete Notes Be sure to turn off the charger s power after charging is complete in order to save standby power The infrared wireless microphone becomes warm after charging completion however this is not a failure Hold the charger when detaching the infrared wireless microphone from the charger 6 TROUBLESHOOTING Symptom Po
2. FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required correct the interference at his own expense e Make sure to observe the following handling precautions so that a fire or personal injury does not result from leakage or explosion of the battery Be sure to use only the rechargeable battery designed for use with the infrared wireless microphone Avoid mixed use of new and old batteries batteries of different types or fully charged and discharged batteries in the same microphone Do not short disassemble heat nor put the battery into a fire Do not solder a battery directly Note correct polarity positive and negative orientation when inserting a battery in the unit Avoid locations exposed to the direct sunlight high temperature and high humidity when storing batteries The TOA IR 200BC is a dedicated battery charger for the IR 200M and IR 300M Infrared Wireless Microphones It employs a quick charging system for nickel metal hydride NiMH batteries allowing up to 2 infrared wirele
3. may result Clean it periodically In addition insert the plug in the wall outlet securely Switch off the power and unplug the power supply plug from the AC outlet for safety purposes when cleaning or leaving the unit unused for 10 days or more Doing otherwise may cause a fire or electric shock Use the dedicated AC adapter for the unit Note that the use of other adapter may cause a fire Avoid charging microphones installed with rechargeable batteries other than the dedicated IR 200BT battery Charging any other than the specified battery could result in fire or personal injury due to battery rupture When the infrared wireless microphone is not in use for 2 weeks or more be sure to take the batteries out of the microphone because battery leakage may cause a fire personal injury or contamination of environment operation 2 GENERAL DESCRIPTION FCC Compliance This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired Any modifications made to this device that are not approved by TOA Corporation may void the authority granted the user by the FCC to operate this equipment Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the
4. reached the end of its life cycle usually after about 500 charges and discharges Replace the rechargeable battery with a new one Full charge indicator does not light even 3 hours after charging has been started maximum charging time 3 hours The infrared wireless microphone s power switch may be set to ON The battery may be at the end of its life Set the infrared wireless microphone s power switch to OFF Replace the rechargeable battery with a new one Both the charging indicator red and the full charge indicator green light alternately The microphone may have been installed with a non IR 200BT rechargeable battery There may be foreign objects such as metals in the microphone receptacle The battery may be at the end of its life The infrared wireless microphone s power switch may be set to ON Use a dedicated IR 200BT rechargeable battery in the infrared wireless microphone Remove such foreign objects Replace the rechargeable battery with a new one Detach the infrared wireless microphone from the charger and set the microphone power switch to the OFF position then reinsert the microphone into the charger 7 SPECIFICATIONS Power Source AC mains 50 60 Hz Power is supplied from the enclosed AC adapter Current Consumption Max 2A Charging Time Max 3 hours Number of wireless 2 pieces microphones to be charged simultaneously Operating Tempera
5. Zu OA Y OPERATING INSTRUCTIONS BATTERY CHARGER IR 200BC g N TABLE OF CONTENTS 1 SAFETY PRECAUTIONS 2 5 CHARGING eee 5 2 GENERAL DESCRIPTION 3 6 TROUBLESHOOTING 7 3 HANDLING PRECAUTIONS 3 7 SPECIFICATIONS e 8 Accessories esesseseeeeeeenennnennen 8 4 NOMENCLATURE AND FUNCTIONS 4 Thank you for purchasing TOA s Battery Charger Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment TOA Corporation 1 SAFETY PRECAUTIONS Before installation or use be sure to carefully read all the instructions in this section for correct and safe operation Be sure to follow all the precautionary instructions in this section which contain important warnings and or cautions regarding safety After reading keep this manual handy for future reference A WARNING N CAUTION Indicates a potentially hazardous situation which if mishandled could result in death or serious personal injury Indicates a potentially hazardous situation which if mishandled could result in moderate or minor personal injury and or property damage A WARNING When Installing the Unit Do not expose the unit to rain or an environment where it may be splashed by water or other liquids as doin
6. and remove the microphone from the charger during charging as this could reduce the number of times that the IR 200BT can be effectively charged and discharged Rechargeable batteries are consumables and do not last indefinitely If the battery operating time becomes extremely short even when it has been fully charged the battery has reached the end of its life and must be replaced Be sure to replace the battery with one designated for use with the microphone IR 200BT Tip Under normal use conditions the battery can cycle through approximately 500 charges and discharges after which it will usually need to be replaced amp IR 200M optional d Mounting adapter 1 pre installed 4 Power switch e Full charge Em indicator IR 300M optional Power input terminal M p e 3 6 Charging indicator a Power switch Supplied AC adapter p Power indicator 1 2 Handling the power cord O AC adapter plug 5 O To AC wall outlet Supplied power cord Cord Bottom view of the charger J Step 1 Connect the power cord to the AC adapter then connect the AC adapter to the charger Once connected push the cord into the slot in the charger s bottom surface to prevent the AC adapter plug from accidentally slipping out of place Refer to Handling the power cord in the figure above Step 2 Insert the AC power plug into an AC wall outlet Step 3 Set the charger s power switch to ON
7. g so may result in fire or electric shock e Use the unit only with the voltage specified on the unit Using a voltage higher than that which is specified may result in fire or electric shock Do not cut kink otherwise damage nor modify the power supply cord In addition avoid using the power cord in close proximity to heaters and never place heavy objects including the unit itself on the power cord as doing so may result in fire or electric shock Avoid installing or mounting the unit in unstable locations such as on a rickety table or a slanted surface Doing so may result in the unit falling down and causing personal injury and or property damage When the Unit is in Use Should the following irregularity be found during use immediately switch off the power disconnect the power supply plug from the AC outlet and contact your nearest TOA dealer Make no further attempt to operate the unit in this condition as this may cause fire or electric shock If you detect smoke or a strange smell coming from the unit If water or any metallic object gets into the unit If the unit falls or the unit case breaks If the power supply cord is damaged exposure of the core disconnection etc To prevent a fire or electric shock never open nor remove the unit case as there are high voltage components inside the unit Refer all servicing to your nearest TOA dealer Do not place cups bowls or other containers
8. ng indicator Lights red continuously while charging is in NEAN progress 3 Power indicator Lights when the power is switched on Power input terminal EM Connect the supplied AC adapter to this terminal 4 Screwdriver inlet Insert the setting screwdriver supplied with the infrared wireless microphone into this inlet when storing it Indicator status table Charging indicator red Full charge indicator green Status Lit Unlit Charging in progress Unlit Lit Charging completed Flashing Unlit Outside the operating temperature range refer to p 7 Troubleshooting Both indicators light alternately Charging failure refer to p 7 Troubleshooting 5 CHARGING Avoid charging microphones installed with rechargeable batteries CAUTION other than the dedicated IR 200BT battery Charging any other than the specified battery could result in fire or personal injury due to battery rupture Notes Use the charger in locations where the ambient temperature range is between 0 and 40 C 32 to 104 F Charge the IR 200BT battery before using it If an infrared wireless microphone containing an IR 200BT battery has been stored for a long period of time itis recommended that the microphone be charged before use Avoid using the charger in locations subject to strong vibrations as the resulting poor electrical contact may prevent correct charging Do not frequently insert
9. of liquid or metallic objects on top of the unit If they accidentally spill into the unit this may cause a fire or electric shock Do not insert nor drop metallic objects or flammable materials inside the battery charger or its infrared microphone receptacle as this may result in fire or electric shock Do not touch a power supply plug during thunder and lightning as this may result in electric shock Stop charging if the batteries are not fully charged within 3 hours Failure to do so may cause the batteries to fire explode leak or heat A CAUTION When Installing the Unit Never plug in nor remove the power supply plug with wet hands as doing so may cause electric shock When unplugging the power supply cord be sure to grasp the power supply plug never pull on the cord itself Operating the unit with a damaged power supply cord may cause a fire or electric shock When moving the unit be sure to remove its power supply cord from the wall outlet Moving the unit with the power supply cord connected to the outlet may cause damage to the power supply cord resulting in fire or electric shock Avoid installing the unit in humid or dusty locations in locations exposed to the direct sunlight near the heaters or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use If dust accumulates on the power supply plug or in the wall AC outlet a fire
10. ss microphones to be fully charged within 3 hours 3 HANDLING PRECAUTIONS Since the supplied power cord is designed for use specifically with the IR 200BC charger do not use it with equipment other than the IR 200BC Use the IR 200BC in locations where an ambient temperature ranges from 0 to 40 C 32 to 104 F When cleaning the case be sure to first switch off the power then wipe with a dry cloth Never use benzene thinner alcohol or chemically processed towels as these may damage the charger s components and parts Clean the charging terminals on a regular basis using a dry cotton swab Dirty terminals can cause poor electrical contact and cause batteries to be charged incorrectly 4 NOMENCLATURE AND FUNCTIONS de A 1 Power switch 5 Infrared wireless microphone receptacle To turn on the power set this switch to the Use the mounting adapter when charging the position To turn off the power shift this switch IR 200M microphone back When charging the IR 300M microphone remove the mounting adapter and insert the 2 Mounting Adapter microphone directly into the receptacle factory attached to the charger Used when charging the IR 200M handheld Full charge indicator infrared wireless microphone Lights green once the battery is fully charged Remove this adapter when charging the IR 300M hands free infrared wireless microphone Refer to p 5 Charging o J Chargi
11. ture 0 to 40 C 32 to 104 F Operating Humidity 30 to 85 RH Finish Case ABS resin metallic gray 50 gloss paint Microphone receptacle section PPE resin black Dimensions 238 w x 83 h x 98 d mm 9 37 x 3 27 x 3 86 Weight 635 g or 1 4 Ib charger with the mounting adapters attached Note The design and specifications are subject to change without notice for improvement Accessories Power cord 2 m or 6 56 ft 3 aeaiiai Aa Aaina eene 1 AC adapter DC cord length 1 5 m or 4 92 ft leessen 1 Mounting adapter pre installed sseeeenenn 2 Optional products Rechargeable battery IR 200BT 2 containing 2 pieces Using the mounting adapter allows one each of the IR 200M and IR 300M to be charged in combination Height is 109 5 mm 4 31 when the mounting adapter is installed 3 Not supplied with the IR 200BC KR For the usable power supply cord and AC adapter contact your nearest TOA dealer Traceability Information for Europe EMC directive 2004 108 EC Manufacturer Authorized representative TOA Corporation TOA Electronics Europe GmbH 7 2 1 Minatojima Nakamachi Chuo ku Kobe Hyogo Suederstrasse 282 20537 Hamburg Japan i Germany PA URL http www toa jp E TOA Corporation moo BSds
12. wer indicator does not light even if the power switch is turned on Possible cause e The AC adapter is not plugged into a working AC outlet or is not plugged in correctly AC adapter plug is not connected to the charger e Make sure the AC adapter is plugged in to a working AC wall outlet correctly Connect the plug to the charger s power input terminal Charging indicator red does not light even when the infrared wireless microphone is inserted into the microphone receptacle The batteries used in the microphone may not be dedicated IR 200BT rechargeable batteries The infrared wireless microphone may not be seated correctly in the microphone receptacle For the IR 200M The mounting adapter may not be installed correctly Install the appropriate dedicated IR 200BT rechargeable battery in the microphone Make sure that the microphone is inserted fully into charger as far as it will go Install correctly the mounting adapter Inserting the infrared wireless microphone into the microphone receptacle causes the charging indicator red to flash The ambient temperature may exceed the permissible operating temperature range 0 to 40 C or 32 to 104 F preventing charging Perform charging within the operating temperature range 0 to 40 C or 32 to 104 F Full charge indicator green always lights soon The dedicated IR 200BT rechargeable battery has probably