1. Connect one end of a fiber jumper to the SC connector on this converter and the other end of the fiber jumper to the SC connector on the other 1000Base SX LX device Attach the power adapter DC jack to the converter Verify that the Power LED is on Verify that the UTP LK ACT LEDs light when cable connection is installed correctly Verify that Fiber LK ACT LED blinks to indicate network activity Troubleshooting Verify that you are using the right power adapter DC 5V 2A minimum Using a power adapter with DC output greater than 5V could result in damage to the unit and or personal injury Confirm the proper UTP Fiber cable is being used The Single Mode converter must use Single Mode fiber optic cable Installing Converters into Chassis Follow the steps below to install modular converters into the 10 space Converter Chassis pn FEP 593110 A Remove the blank bracket from the chassis by rotating screw counterclockwise Put the blank bracket aside B Open the rack mount bracket kit The kit contains two rack mount brackets and four screws C Use a screwdriver to attach the rack mount ears to both sides of the modular converter D Install the modular converter by inserting it into the chassis guides and sliding it in until it stops Press it firmly to seat the chassis power plug into the modular converter receptacle E Gently push the thumbscrews in and turn clockwise to tighten Do
2. Operating Humidity EMI Enclosure Dimensions Warranty FCC Statement IEEE 802 3 10 100 1000Base T Gigabit Ethernet IEEE 802 3 1000Base SX LX Gigabit Ethernet CSMA CD 1 10 100 1000Base T Shielded RJ 45 Jack 1 1000Base SX LX Dual SC connector 10 100 1000Base T Cat 5e or 6 up to 100m 1000Base SX Multi mode fiber 50 125um 550m 62 5 125um 550m 1000Base LX Single Mode fiber 9 125um 10Km Power Speed Link Activity copper and fiber Full Duplex copper Full Duplex collision fiber External power adapter 9V DC 700mA min 0 C to 45 C 10 90 RH FCC Class A CE Mark Metal 120mm x 85mm x 26mm L x W x H Limited Lifetime This equipment has been tested and found to comply with the limits for a class B device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a commercial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with instructions may cause harmful interference with radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s expense Introduction Congratulations on purchasing a quality UNICOM product Unicom s VELOCITY Series represents the newest most advanced generation of sign
3. Auto Negotiation Function Support Fiber parameters Fiber Core Multi Mode 62 5 125um 50 125um Single Mode 9 125um Wavelength 850nm Multi mode 1310nm Single mode Fiber Distance 550m Multi Mode Fiber 10km Single Mode Fiber Link Loss Forward Copper to Fiber lf copper port link down then media converter will forced fiber to link down Fiber to Copper f Fiber port link down the media converter will forced copper port to link down Cabling Twisted pair segments can be Unshielded Twisted Pair UTP or Shielded Twisted Pair STP cabling The cable must comply with the IEEE 802 3 10 100 1000Base T standard for Category 5e 6 The cable between the converter and the link partner switch hub workstation etc must be 100 meters 328 ft or less in length Fiber segments using Single Mode connectors must use 9 125um Single Mode fiber cable The maximum link distance in full duplex operation is 10 Kilometers 6 2 miles The maximum link distance in half duplex operation is 412 meters 1352 ft The maximum distance of fiber segments using Multi Mode connectors measures 550 meters 1804 ft with 50 125um or 62 5 125um Multi Mode fiber cable Network Connection A Select the appropriate length Category 5e or 6 twisted pair cable Connect one end of the twisted pair cable to the RJ 45 connector on the converter and the other end of twisted pair cable to the RJ 45 connector on any 10 100 1000Base T device
4. A Network Systems Solution U INI ICOM For full coverage of your warranty be sure to register your product using the enclosed registration card 10 100 1000Base T 1000Base SX LX Gigabit Ethernet Converter GEP 5300TF C 1000Base T SX SC MM 550m GEP 5400TF C 1000Base T LX SC SM 10km Rev 2 0 A Network Systems Solution U NI ICOM 908 Canada Court City of Industry CA 91748 U S A Phone 626 964 7873 or 800 346 6668 Fax 626 964 7880 www unicomlink com e mail info unicomlink com Auto MDI MDIX User s MANUAL UNICOM 2009 UNICOM and A Network Systems Solution are trademarks of UNICOM Electric Inc All rights reserved Specifications subject to change without notice Rev 06 09 Package Contents Package contents include the following mM 10 100 1000Base T to 1000Base SX LX Converter Multi Mode or Single Mode m DC Power Adapter m User s Manual m Rack Mount Brackets Warranty card not shown Gigabit User s Manual Power Adapter Rack Mount Converter Brackets Multi Mode or Single Mode IMPORTANT If any piece is missing or damaged please contact your local dealer or reseller for service For Your Records Product Name Serial Number Date of Purchase Purchased from Notes 10 Product Specifications Standard Compliance Protocol Interface Cable distance LED Indicators Power Supply Operating Temperature
5. al conversion technology Unicom s Giga Fiber Converter is a cost effective solution for the conversion of 10 100 1000Base T Auto MDI MDIX and pure 1000 Base T to 1000Base SX LX cabling It can be slotted into a multi converter chassis that enhances your network flexibility It can also be used as a stand alone converter The Giga Fiber Converter will allow you to extend the cabling distance of your 10 100 1000Base T Auto MDI MDIX or pure 1000 Base T network up to 550m for multi mode fiber or 10 kilometers for single mode fiber This Converter uses the most popular fiber cabling connectors SC multi mode fiber connector and SC single mode fiber connector The Modular Giga Fiber Converters provides one Fiber connector for fiber optic cable and one Ethernet RJ 45 port Auto MDI MDIX for 10 100 1000Base T copper cable or pure 1000 Base T copper cable connections There are DIP switches to set the operation mode for UTP Fiber ports and link lost forwarding function Key Features Standards LED Indicators Connector IEEE 802 3 1OBASE T IEEE 802 3u LOOBASE TX IEEE 802 3ab 1000BaseT IEEE 802 3z 1000BaseSX LX standards IEEE 802 3x Flow Control and Back pressure Power Green UTP SPD 1000Mbps 100Mbps 10Mbps Lnk Act UTP FIBER FDX UTP Full Duplex mode Half Duplex or Link down FIBER Full Duplex mode Link down Fiber Duplex SC RJ 45 Socket CAT 5e 10 100 1000Mbps Twisted Pair cable Auto MDI MDI X and
6. er mode OFF the converter function is the same as a Switch Hub Note 1 Do not change the DIP switch setting when the copper or fiber port is transmitting or receiving data It may cause data error 2 Power off then power on when changing the DIP switch setting
7. ese LEDs tep status color Descrition PWR On Green e The converter is supplied with suitable power e Current UTP Speed is LOOOMbps Bee e Current UTP Speed is LOOMbps Current UTP Speed is 10Mbps LK ACT e Unit is connected with a link UTP e Unit is transmitting data e No device attached LK ACT e Unit is connected with a link Fiber e Unit is transmitting data e No device attached FDX COL e The UTP port is in fullduplex mode Fiber e No device attached DIP Switch Description The DIP switch is used to configure operation mode for LLF Link Lost Forwarding and operation mode for Copper Fiber port The default value of Dipswitch is OFF 10 100 1000Base T to 1000Base FX converter module 1 Off LLF enabled On LLF disabled Off Switch Coverter Mode On Pure Converter Mode Off Reserved On Reserved Link Lost Forwarding When LLF is enabled it will allow copper port link failure to be reported to the Fiber side and will also allow Fiber link failure to be reported to the copper side Therefore a link loss forward feature is provided on both copper and Fiber sides Pure Converter mode When Pure Converter mode is enabled ON the switch operates with the minimum latency The transmission flow does not wait until an entire frame is ready but instead forwards the received data immediately after being received The TP should be forced at 1000M in this application When the DIP Switch is in Switch Convert
8. not over tighten Hardware Description The Front Panel The Front Panel of the 10 100 1000T to 1000SX LX converters consists of one RJ 45 Port Auto MDI MDIX one fiber 1000Base SX LX Port and 6 LED Indicators SPD LK ACT FDX Fiber LK ACT FDX COL and PWR 10 100 1000T SPD PWR 100Base SX Auto MDI MDIX Encae Multi Mode GEP 5300TF C 550m 10 100 1000T PWR 1000Base LX SPD O O n1 EaR kefe Auto MDI MDIX Pouca Single Mode GEP 5400TF C 10km Ports e Copper Port RJ 45 Port Auto MDI MDIX the Ethernet RJ 45 will features Auto Sensing for 10 100 1000Base T connections and Auto MDI MDIX which is basically an auto crossover feature This means you can connect to another Switch or workstation without changing to a crossover cable e Fiber Port This port is for the 1000Base SX LX connection and is available in the SC format in Multi and Single mode This fiber port does not support auto negotiation The Rear Panel DC IN O The rear panel contains a power socket This power socket accepts DC9V voltage and minimum 0O 7A supplied current LED Indicators There are six diagnostic LEDs located on the front panel of these converters The LEDs provide real time information on system status The indicators include SPD LK ACT FDX Fiber LK ACT FDX COL and PWR The following table provides describes th

Download Pdf Manuals

image

Related Search

Related Contents

OnTOP for Series 90-70 Online Troubleshooting and Operator  Eagle EHCN1 Instructions / Assembly  Mackie SWA1501 User's Manual  FSE en visite 1/2007  Gravador de Vídeo Digital Divar MR  Density.m4l.v2 user manual  Ihr - Gericom  User Guide - Primary ICT  Readiris User`s Manual  Netgear WG121 User's Manual  