1. LED is not illuminated amp Red LED is Low Pressure Switch has tripped allow for Auto Reset illuminated Low Pressure Switch will not Auto Rest Red LED Low Refridgerant Charge Contact Local Dealer remains illuminated Fog will not remain on ground Ensure the use of Ultratec Special Effects Fluid Check digital temperature display reading for coil temperature Check Green and Red LED see above Green LED goes out when unit is operating and Check Power Source for sufficient voltage Do NOT use Red LED doesn t illuminate extension cords Condensation on floor Floor seems slippery 4 Too much fog going through LSX 5 Fog machine nozzel is too close to LSX 6 Reduce fog output or duration Recommended Fluids Molecular Fog Fluid A faster dissipation versus the Director s Choice Fog Fluid This thick clean white fog is an optimal solution for a dense low lying fog effect when chilled with the LSG or LSX machines Maintenance Fluid EZ Kleen Preventative Maintenance Fluid Using EZ Kleen preventative maintenance fluid on a regular basis ensures longer life for the heat exchanger in Ultratec fog machines by reducing blockage All of our Fog Fluids are water based Damage will occur if Haze Fluid is used ultratec 6 www ultratecfx com special effects inc Warranty Warranty All warranty is for one year parts and labour unless specified or manufacturer defect only Abuse or Poo
2. inc Technical Specifications Model Part Number Length Width Height Net Weight Power Rating Fluid LSX Low Smoke Converter CLF 2930 120 volt CLF 2915 240 volt 59in 150cm 29 5in 75cm 28in 71cm 150lbs 68kg 120 Volt A C 50 60 Hz 12 Amps 240 Volt A C 50 60 Hz 6 Amps Ultratec Special Effects Water Base Fog Fluid Technical Drawings 4 www ultratecfx com ultratec special effects inc Operating Procedure 1 During use this machine generates condensation After use the LSX should be drained via the drain valve CAUTION This may cause the floor to become very slippery This may also inhibit the performance of the LSX unit 2 This unit requires a 15 amp circuit to run properly The use of any extension cords or shared circuit is strongly not recommended 3 It is essential that Ultratec Special Effects s Genuine Molecular Fluid is used in the Fog Machine to achieve optimum effect 4 The LSX unit is controlled by a user friendly panel When the system switch is in the On position and illuminated power is established to the LSX unit A green led is provided to indicate the compressor is operating 5 An Automatic Reset Low Pressure Switch is provided as protection against compressor damage If the Low Pressure Switch has been activated the Red LED will illuminate the Green LED will not be illuminated 6 The Variable Fan Control regulates F
3. LSX Low Smoke Converter Operator s Manual ultratec ae special effects inc VER 30 10 10 Table of Contents Tat cole 0 eto nce 3 Warning ahnen 3 Important Safety Instructions eennennn 3 Safety Precautions eeneeenmnennnen 3 Technical Specifications eeenene 4 Technical Drawings 20 222042n0nnnnsnnnnnnnnnnnnnnnenennenn nn 4 Operating Procedure nennenneenen 5 Control Panel Operations een 5 Before Requesting Service emnnnenn 6 Recommended Fluids eenennnen 6 Maintenance Fluid 6 Warranty nennen kann 7 Contact Information een 7 Note Please read entire manual before operating the LSX a 2 www ultratecfx com ultratec special effects inc Introduction Congratulations on your purchase of a Ultratec Special Effects LSX MKII Low Smoke Convertor With basic care your LSX will provide years of trouble free performance The LSX is a product of many years of research and development resulting in a machine with many fine features and exceptional reliability This manual contains detailed information on the operation of your LSX Please take a few moments to read it over carefully before use and keep it handy for your reference Warning I
4. er to the Product Manual for proper use Contact Information Head Office Canadian Shipping Address USA Shipping Address Ultratec Special Effects Inc For All Canadian Repairs For All USA Repairs 1960 Blue Heron Drive Ultratec Special Effects Inc Ultratec Special Effects Inc London Ontario N6H 5L9 1960 Blue Heron Drive 640 Gadson St London Ontario N6H 5L9 Groveland Florida 34736 Direct 519 659 7972 Toll Free 866 534 5557 Please remember to include the RA Number on all items being shipped for Fax 519 659 7713 repairs To get an RA Number visit www ultratecfx com and click on the Service tab and then click on Master Service Tracker or contact service at 519 951 3357 866 534 5557 ultratec www ultratecfx com 7 special effects inc
5. mportant Safety Instructions 1 Do not touch place hands or expose skin within 20 50 cm of the discharge nozzle 2 Do not remove the outer case 3 Persons suffering from asthma or allergenic sensitivity may experience irritation discomfort or allergic symptoms when exposed to fog effects 4 Ensure that this unit is grounded at all times Failure to do so may result in serious injury 5 Use Ultratec Special Effects fluid ONLY Safety Precautions 1 Ensure that any operation of the machine is supervised by suitably trained and authorized personnel Do not modify the machine or use a machine which has been damaged in any way Allow sufficient air circulation around the machine at all times Protect the machine from direct weather effects and wet locations Only use fluids manufactured by Ultratec Special Effects Do not continue to produce fog when visibility is reduced to 20 50cm or below NO Ww A WU N Avoid directing fog output continuously at people structures or objects within close proximity of the discharge nozzle ee Ensure that adequate exhausting arrangements are available in the event of an emergency 9 Do not place hands or exposed skin within the first 20 50 cm of the discharge nozzle at any time during fog production 10 Fog effects can trigger smoke alarms and detectors Please take suitable precautions to prevent false alarms ultratec www ultratecfx com 3 special effects
6. og Density Output Some experimenting will produce various effects An OFF position is provided on this control It is not recommended that this control be left in the off position as this will eventually result in activation of the Low Pressure Switch and cause a freeze up condition Control Panel Operations 1 Fan Knob this controls the speed of the lower fan Turning clockwise reduces the speed Off is at the counter clockwise end Note It is not recommended to leave the control left in the Off position or in a very low setting the low pressure switch may activate turning off the compressor 2 Low Pressure Light when lit indicates that Low Pressure Protection has been activated The Low Pressure Switch will automatically reset but may take 2 3 cycles to start unless a leak has occurred in the system 3 Compressor Light compressor is operating normal when lit 4 Power Switch power is on when lit Note A cooler ambient temperature may result in activation of Low Pressure Switch within a short period of time after initial start up To remedy this problem the unit can be stored in a warm location a load can be put on the cooling chamber by introducing warm fog into the unit just after start up or by simply covering the top of the unit to stop air flow gt t ultratec www ultratecfx com 5 special effects inc Before Requesting Service If LSX will not Power Up Check Power source and connections Green
7. r Maintenance will not be covered under warranty Ultratec Special Effects Fluids must always be used Use of any non Ultratec Special Effects Fluids will void all warranties Accept no substitutions as there are no exceptions to this rule Proof of Purchase or Proof of Sale must always accompany any warranty returns An RA return authorization number must be noted on the outside of the box being returned to our facilities Any packages without a clearly marked RA number will not be accepted by our receiving department Freight on warranty items are freight prepaid to our facility and we will prepay freight back to your facility after repair by the most economical means available Should you require the item express returned then you are responsible for any difference in freight cost Return Policy Return of any product must be done within 30 days of purchase The package must be returned freight prepaid and the RA number clearly marked on the outside of the box Minimum restocking fee is 25 Once our facility has received the product a technical assessment will be completed to determine if an additional restocking fee needs to be issued Only credits are issued to the dealers account Any product not returned within 30 days is considered purchased Ultratec Special Effects Inc considers all of it s product to be safe for use in the application it was intended Ultratec Special Effects takes no responsibility for misuse or incorrect use Always ref