Home

Troy-Bilt 6250 Watt Portable Generator User's Manual

image

Contents

1. 16 Operation cun ceases censte ss che debdeneseea ace 17 Starting the Engilia 200 350 24 ceed be RR ea big RE RR e ales 17 Connecting Electrical 0 18 Stopping the Enging RI 18 Low Oil Shutdown 18 Cold Weather 18 Don t Overload 20 21 Maintenance 5 21 Generator Maintenance 21 Fuel Valve Maintenance ooa secesie eee eens 21 Engine Maintenance 2 0 eens 22 nico LETT 25 Troubleshooting 0000 eee eee ees 26 Warranties 27 Emissions Control System 27 Generator Owner Warranty 29 30 Product lt 30 Common Service Parts 30 troybilt com Operator Safety Safety Labels The generator safety labels shown below and on the next page are placed on your portable generator to draw attention to potential safety hazards
2. Gi Y v podr a provocar quemaduras incendios 0 explosiones as como lesiones graves incluso la muerte CUANDO ANADA COMBUSTIBLE DETENGA el motor del generador y d jelo enfriar durante al menos 2 minutos antes de quitar el tap n de combustible Afloje la tapa lentamente para dejar que la presi n salga del tanque Llene el dep sito de combustible a la intemperie NO demasiado el tanque Permita al menos espacio para la expansi n del combustible Si se ha derramado combustible espere a que se evapore antes de arrancar el motor Mantenga la combustible alejada de chispas llamas abiertas pilotos calor y otras fuentes de ignici n Compruebe frecuentemente que las l neas de combustible el tanque el tap n y los accesorios no est n rotos o tengan fugas C mbielos si es necesario NO encienda un cigarrillo o fume Para evitar la formaci n de carbonilla en el circuito de combustible siempre que a ada combustible m zclelo con un estabilizador Consulte Almacenamiento No todos los combustibles son iguales Si detecta problemas de arranque o de rendimiento despu s de utilizar un combustible pruebe a cambiar de proveedor o de marca Este motor est certificado para funcionar con gasolina Su sistema de control de emisiones es EM Modificaciones del motor 1 Limpie el rea alrededor de la tapa de llenado del combustible retire la tapa 2 A ada lentamente gasolina sin plomo C al tanque
3. Luz 75 Vatios Total 3075 Vatios para 1800 Vatios de funcionar Carga m Vatios de potencia continua totales 3075 Potencia de salida adicional m s alta 1800 Salida total del generador requerida 4075 Control de la energ a Para prolongar la vida de su generador y los aparatos que conecte a l es muy importante tener cuidado cuando se le afiaden cargas el ctricas No deber haber nada conectado las tomas del generador antes de encender el motor El modo seguro y correcto de gestionar la energ a del generador es a adir las cargas secuencialmente como se indica a continuaci n 1 Sin tener nada conectado al generador encienda el motor tal como se describe en este manual 2 Conecte y encienda la primera carga preferiblemente la mayor que usted tenga 3 Permita que la salida del generador se estabilice el motor funciona suavemente y el aparato funciona adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 20 6 Repita los pasos 4 y 5 para cada carga adicional que usted tenga NUNCA afiada cargas que sobrepasen la capacidad del generador Tenga especial cuidado en contar con las cargas adicionales en la capacidad del generador como se describe arriba Gu a de Referencia de Potencia Vatios de potencia continua Vatios de potencia Herramienta o aparatoa end P de salida adicional B sicos N Bombilla de 75 v
4. oil must be at proper level for engine to start A WARNING Exhaust heat gases could ignite N combustibles structures or damage fuel 4 S EN tank causing a fire resulting in death or serious injury Contact with muffler area could cause burns resulting in serious injury DO NOT touch hot parts and AVOID hot exhaust gases Allow equipment to cool before touching Keep at least 5 feet 1 5 m of clearance on all sides of generator including overhead It is a violation of California Public Resource Code Section 4442 to use or operate the engine on any forest covered brush covered or grass covered land unless the exhaust system is equipped with a spark arrester as defined in Section 4442 maintained in effective working order Other states or federal jurisdictions may have similar laws Contact the original equipment manufacturer retailer or dealer to obtain a spark arrester designed for the exhaust system installed on this engine Replacement parts must be the same and installed in the same position as the original parts 5 Grasp recoil handle and pull slowly until slight resistance is felt Then pull rapidly one time only to start engine e If engine starts proceed to step 7 e If engine fails to start proceed to step 6 A WARNING Starter cord kickback rapid retraction J will pull hand and arm toward engine faster than you can let go which could cause broken bones fractures bruises or sprains result
5. 5 feet 1 5 m from any structure overhang trees windows doors any wall opening shrubs or vegetation over 12 inches 30 5 cm in height DO NOT place portable generator under a deck or other type of structure that may confine airflow Smoke alarm s MUST be installed and maintained indoors according to the manufacturer s instructions recommendations Carbon monoxide alarms cannot detect smoke DO NOT place portable generator in manner other than shown EXAMPLE OF LOCATION TO REDUCE THE RISK OF FIRE 4 5 ft 1 5 m Exhaust direction away from occupied spaces e 14 troybilt com Features and Controls CT Read this Operator s Manual and safety rules before operating your generator Compare the illustrations with your generator to familiarize yourself with the locations of various controls and adjustments Save this manual for future reference A Circuit Breakers AC The 120 Volt AC 20A duplex receptacles are provided with push to reset circuit breakers to protect the generator against electrical overload B Oil Fill Cap Dipstick Check and add engine oil here C Oil Drain Plug Drain engine oil here D Grounding Fastener Consult your local agency having jurisdiction for grounding requirements in your area E Spark Arrester Muffler Exhaust muffler lowers engine noise and is equipped with a spar
6. A DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home Only use OUTSIDE and or garage EVEN IF doors far away from windows and windows are open doors and vents 202997 Fire Hazard Fuel is flammable which could cause burns resulting in death or serious injury DO NOT fill fuel above baffle Always allow space for fuel expansion 319065 Fire hazard Hot exhaust and reflective exhaust gases could cause burns and fires resulting in death or serious injury Keep at least 5 ft 1 5 m clearance from any combustibles or structures including overhead 319066 A WARNING Failure to read and L follow the operator s manual all warnings and operating instructions could result in death or serious injury Poisonous Gas Hazard Engine exhaust contains carbon monoxide a poisonous gas that could kill you in minutes You CANNOT smell it see it or taste it Operate this product ONLY outside far away from windows doors and vents Install battery operated carbon monoxide alarms in home Fire Hazard Fuel and its vapors are flammable which could cause burns resulting in death or serious injury Turn engine off and let it cool at least 2 minutes before refueling Never add fuel to a hot or running generator Shock Hazard Generator voltage could cause electrical shock re
7. BRIGGSandSTRATTON COM Net power values are taken with exhaust and air cleaner installed whereas gross power values are collected without these attachments Actual gross engine power will be higher than net engine power and is affected by among other things ambient operating conditions and engine to engine variability Given the wide array of products on which engines are placed the gasoline engine may not develop the rated gross power when used in a given piece of power equipment This difference is due to a variety of factors including but not limited to the variety of engine components air cleaner exhaust charging cooling carburetor fuel pump etc application limitations ambient operating conditions temperature humidity altitude and engine to engine variability Due to manufacturing and capacity limitations Briggs amp Stratton may substitute an engine of higher rated power for this engine This generator is rated in accordance with CSA Canadian Standards Association standard C22 2 No 100 04 motors and generators and PGMA Portable Generator Manufacturers Association standard PGMA G200 Standard for Testing and Validating Performance of Portable Generators Briggs amp Stratton Power Products Group LLC P 0 Box 702 Milwaukee Wisconsin 53201 0702 U S A 30 888 611 6708 troybilt com OTROY BILT Generador portatil Manual del Operario gt Sa Este generador est clasific
8. S La cobertura no aplica a los fallos de componentes relacionados con el sistema de emisiones cubiertos por la garant a que no sean originales de B amp S ni a los fallos debidos a uso indebido negligencia o mantenimiento inadecuado conforme a las disposiciones de la pol tica de garant a de motores B amp S B amp S no ser responsable de la cobertura de la garant a de fallos de componentes relacionados con el sistema de emisiones cubiertos por la garant a provocados por el uso de componentes complementarios o modificados 28 Consulte la informaci n sobre el per odo de durabilidad de las emisiones y el ndice de aire en la etiqueta de emisiones del motor pequefio para m quinas de servicio Los motores con certificaci n de cumplimiento de la normativa sobre emisiones de motores pequefios para m quinas de servicio del California Air Resources Board CARB deben mostrar informaci n sobre el per odo de durabilidad de las emisiones y el ndice de aire Briggs amp Stratton ofrece esta informaci n al consumidor mediante etiquetas de emisiones La etiqueta de emisiones del motor contiene la informaci n de certificaci n El Per odo de Durabilidad de las Emisiones indica el n mero de horas durante las cuales el motor puede funcionar cumpliendo las normas sobre emisiones siempre que se realicen las operaciones de mantenimiento que se detallan en las instrucciones de uso y mantenimiento Se utilizan las siguientes categor as M
9. air RIGHT AWAY See a doctor You may have carbon monoxide poisoning A WARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm A WARNING Certain components in this product and related accessories contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm Wash hands after handling N WARNING Starter cord kickback rapid retraction A Will pull hand and arm toward engine faster than you let go which could cause broken bones fractures bruises or sprains resulting in serious injury When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback NEVER start or stop engine with electrical devices plugged in and turned on A WARNING Fuel and its vapors are extremely flammable and explosive which could cause LN burns fire or explosion resulting in death or Serious injury WHEN ADDING OR DRAINING FUEL Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fill or drain fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion If fuel spills wait until it evaporates before starting engine Keep fuel away from sparks open flames pilot lights heat and other ignition sources Check fuel lines tank cap and fittings
10. aire siga los pasos que se detallan a continuaci n 1 Afloje los tornillos B y quite aire la cubierta m s limpia C 2 Con cuidado quite cartucho D de base E 3 Instale limpie 0 nuevo aire la asamblea m s limpia dentro de la cubierta Desh gase del filtro viejo apropiadamente 4 Arme la cubierta m s limpia a rea en la base y apriete los tornillos Servicio del buj a Cambie la buj a ayudar a su motor a arrancar m s f cilmente y funcionar mejor 1 Limpie la zona de alrededor de la buj a 2 Retire e inspeccione la buj a 3 Compruebe la separaci n del electrodo con un calibrador de alambre y ajuste el espacio de la buj a a la medida recomendada si fuera necesario v ase Especificaciones OLLE WD 4 Cambie la bujia si los electrodos estan picados o quemados o si la porcelana est agrietada Utilice la bujias de repuesto recomendada Consulte Especificaciones 5 Instale la bujia y apriete firmemente Espa ol 23 Inspeccione el silenciador y la pantalla apagachispas Inspeccione que el silenciador no presente fisuras corrosi n u otros dafios Desmonte la pantalla apagachispas si cuenta con una y verifique que no presente da os ni obstrucci n por carb n En caso de que se necesiten piezas de recambio aseg rese de usar solamente piezas de recambio originales para el equipo A ADVERTENCIA Los gases y el calor de escape podrian inflamar los
11. amp S para motores no regulados que figura en el Manual del Operario 1 Piezas garantizadas La presente garant a cubre nicamente las piezas que se enumeran a continuaci n piezas del sistema de control de emisiones siempre que tales piezas estuvieran presentes en el B amp S motor y o B amp S suministrado sistema de combustible a Sistema de regulaci n de combustible Sistema de enriquecimiento para arranque en fr o estrangulador electr nico Carburador y piezas internas Bomba de combustible Conducto de combustible acoplamientos del conducto de combustible abrazaderas Dep sito de combustible tap n y cadena Bote de carbono b Sistema de inducci n de aire Filtro de aire Colector de admisi n Linea de purga y ventilaci n C Sistema de encendido Buj a s Sistema de encendido magn tico d Sistema catalizador Convertidor catalitico Colector de escape Sistema de inyecci n de aire o v lvula de impulso e Elementos diversos utilizados en los sistemas anteriores V lvulas y conmutadores de aspiraci n temperatura posici n y temporizados Conectores y unidades 2 Duraci n de la cobertura Durante un per odo de dos afios desde la fecha de compra original B amp S garantiza al propietario original y a todo propietario posterior que el motor est disefiado fabricado y equipado conforme a la normativa vigente adoptada por el Air Resources Board que no tiene defectos de mate
12. and let any spilled fuel evaporate before starting engine High Altitude At altitudes over 5 000 feet 1524 meters a minimum 85 octane 85 AKI 89 RON gasoline is acceptable To remain emissions compliant high altitude adjustment is required Operation without this adjustment will cause decreased performance increased fuel consumption and increased emissions See an authorized dealer for high altitude adjustment information Operation of the engine at altitudes below 2 500 feet 762 meters with the high altitude kit is not recommended System Ground The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles The system ground is connected to the AC neutral wire the neutral is bonded to the generator frame Special Requirements There may be Federal or State Occupational Safety and Health Administration OSHA regulations local codes or ordinances that apply to the intended use of the generator Please consult a qualified electrician electrical inspector or the local agency having jurisdiction n some areas generators are required to be registered with local utility companies e f the generator is used at a construction site there may be additional regulations which must be observed Connecting to a Building s Electrical System Connections for standby power to a building s electrical system must use a listed transfer equipment instal
13. apagachispas C 3 Inspeccione la pantalla y reempl cela si est rota perforada o daf ada No use pantallas defectuosas Si la pantalla no est da ada limpiela con un disolvente comercial 4 Vuelva a instalar la pantalla y la protecci n del silenciador 24 Sistema de refrigeraci n de aire Con el tiempo se pueden acumular residuos en las aletas de refrigeraci n del cilindro y pasar inadvertidos mientras no se desmonte parcialmente el motor Recomendamos que encargue la limpieza del sistema de refrigeraci n D a un distribuidor autorizado de Briggs amp Stratton siguiendo los intervalos recomendados consulte la secci n Plan de Mantenimiento en la secci n Mantenimiento Es igualmente importante que no se acumulen residuos en la parte superior del motor ni en la pantalla giratoria Consulte la secci n Limpieza Ajuste del carburador El carburador de este motor es de baja emisi n Est equipado con una v lvula de mezcla de ralent no ajustable y en algunos casos con ralent regulado Los niveles de ralent regulado y velocidad m xima se ajustan en la f brica Si es necesario modificarlos acuda a un distribuidor autorizado N PRECAUCI N Las velocidades de funcionamiento excesivamente altas podr an provocar lesiones leves Las velocidades excesivamente bajas incrementan la carga de trabajo NO intente alterar el resorte las conexiones y otras partes del regulador para incrementar
14. capacidad del amperaje y vataje del generador puede da ar al generador y los aparatos el ctricos conectados al mismo NO sobrecargar el generador V ase No sobrecargar el generador Encienda su generador y deje que el motor se estabilice antes de conectar las cargas el ctricas Conecte las cargas el ctricas en la posici n de apagado OFF luego encienda ON para su operaci n Apague OFF las cargas el ctricas y descon ctelas del generador antes de parar el generador Parada del motor 1 Desconecte todas las cargas el ctricas de los tomacorrientes del panel del generador Nunca de arranque o detenga el motor con todos los dispositivos el ctricos conectados y encendidos 2 Deje que el motor funcione sin cargas por algunos minutos para estabilizar las temperaturas internas del motor y el generador 3 Sit e el interruptor balanc n en la posici n OFF o O 18 A ADVERTENCIA El combustible y sus vapores son extremadamente inflamables y A explosivos lo que podria provocar quemaduras incendios explosiones asi como lesiones graves 0 incluso la muerte NO coloque el estrangulador en la posici n Choke Estrangulamiento para parar el motor 4 Gire la v lvula de combustible hasta la posici n Off Apagado debido a nivel bajo de aceite Si el nivel de aceite del motor cae por debajo del nivel predeterminado el interruptor de nivel de aceite detiene el motor Compruebe el nivel de aceite c
15. con el combustible y aceite recomendados Si usted tiene problemas con el montaje de su generador por favor llame a la l nea de ayuda para generadores al 888 611 6708 Si llamar para la ayuda tiene por favor el modelo la revisi n y el n mero de serie de etiqueta de identificaci n disponible Consulte la ubicaci n en la secci n Controles y caracter sticas Desembalaje del generador 1 Coloque la caja de cart n en una superficie r gida y plana 2 Abra completamente la caja de cart n cortando cada una de sus esquinas de arriba abajo 3 Saque todo el contenido de la caja de cart n a excepci n del generador 4 Mantenga el generador sobre el cart n para instalar el juego de ruedas El generador se entrega con e Manual del operario Juego de ruedas Instale el juego de ruedas AVISO Las ruedas y la patas de apoyo deben fijarse antes de a adir combustible AVISO Este juego de ruedas no ha sido dise ado para ser usado en la carretera Necesitar las herramientas para instalar estos componentes Llaves de 13 mm 2 Alicates Gafas de seguridad Instale el juego de ruedas conforme a las instrucciones siguientes 1 Dele la vuelta al generador de forma que el lado del motor quede abajo 2 Deslice el eje A a trav s del orificios el armaz n del generador 10 3 Deslice el arandela de nylon negro B por encima de eje 4 Deslice una rueda C por encima de eje AVISO Compruebe
16. de combustible D Tenga cuidado de que el nivel de combustible no rebase el l mite E Esto permite dejar el espacio adecuado para que el combustible se expanda como se muestra 3 Instale la tapa del tanque de combustible y la espera para alg n combustible rociado para evaporar Gran altitud En altitudes superiores a 1 524 metros 5 000 pies se deber utilizar gasolina con un m nimo de 85 octanos 85 AKI 89 RON Para seguir cumpliendo la normativa sobre emisiones es necesario ajustar la unidad para su uso a gran altitud De no realizarse este ajuste el rendimiento se reducir y el consumo de combustible y las emisiones aumentar n Para obtener m s informaci n sobre el ajuste para gran altitud consulte con un distribuidor cualificado de Briggs amp Stratton No se recomienda utilizar el motor a altitudes inferiores a 762 metros 2 500 pies con el juego de gran altitud Tierra del sistema El generador dispone de una conexi n a tierra del sistema que conecta los componentes del bastidor a los terminales de tierra de los enchufes hembra de salida de CA La tierra del sistema est conectada al cable de CA neutro que a su vez est conectado al bastidor del generador Requisitos especiales Es posible que haya normas u ordenanzas locales y nacionales en materia de seguridad e higiene en el trabajo aplicables al uso del generador Consulte con un electricista cualificado un inspector el ctrico o el organi
17. de los residuos acumulados Utilice un trapo h medo para limpiar las superficies exteriores AVISO Un tratamiento inadecuado de la generador podr a dafiarla y acortar su vida Util NO exponga al generador a una humedad excesiva polvo suciedad o vapores corrosivos NO inserte cualquier objeto a trav s de las ranuras de enfriamiento Puede usar un cepillo de cerdas suaves para retirar la suciedad endurecida aceite etc Puede usar una m quina aspiradora para eliminar suciedad y residuos sueltos Espa ol 2 Mantenimiento de la valvula de combustible La valvula de combustible esta equipada con un recipiente para sedimentos un filtro y una junta t rica que deben limpiarse 1 Sit e la v lvula de combustible en la posici n Off 2 Extraiga el recipiente para sedimentos A de la v lvula de combustible Retire la junta t rica B y el filtro de la v lvula C 3 Lave el recipiente para sedimentos la junta t rica y el filtro con disolvente no inflamable S quelos perfectamente 4 Sit e el filtro y la junta t rica en la v lvula de combustible Instale el recipiente para sedimentos y apri telo firmemente 5 Sit e la v lvula de combustible en la posici n On y compruebe si hay fugas En caso afirmativo sustituya la v lvula de combustible Mantenimiento del motor A ADVERTENCIA Las chispas involuntarias podr an provocar incendios electrocuci n que 4 N N pueden provo
18. de trabajo o t cnica operativa que no est espec ficamente recomendada por el fabricante debe asegurarse de que no entra ia peligro para usted ni para otras personas Tambi n debe asegurarse de que el procedimiento m todo de trabajo o t cnica operativa elegida no hace que el generador deje de ser seguro S mbolos sobre la seguridad y significados Gases T xicos Contragolpe Descarga El ctrica D Fuego Explosi n Manual del Operario Partes en Movimiento Objetos Voladores Superficie Caliente A El s mbolo de alerta de seguridad indica un posible riesgo para su integridad f sica Se utiliza una palabra de se alizaci n PELIGRO ADVERTENCIA o PRECAUCION junto con el s mbolo de alerta para designar un grado o nivel de gravedad de riesgo Se puede utilizar un s mbolo de seguridad para representar el tipo de riesgo La palabra de se alizaci n AV SO se utiliza para hacer referencia a una pr ctica no relacionada con una lesi n f sica A PELIGRO indica un riesgo que de no evitarse provocar la muerte o lesiones de gravedad A ADVERTENCIA indica un riesgo que de no evitarse podr a provocar la muerte o lesiones de gravedad A PRECAUCI N indica un riesgo que de no evitarse podr a provocar lesiones leves o moderadas AVISO hace referencia a una pr ctica no relacionada con una lesi n f sica A ADVERTENCIA Determinados componentes en este producto y los accesorios relacionados contienen sustanc
19. entre en los espacios habitados Instale alarmas para detectar mon xido de carbono operadas con bater as o enchufables con bater as de repuesto de acuerdo con las instrucciones del fabricante Las alarmas de humo no pueden detectar el gas de mon xido de carbono NO utilice este producto dentro de casas garajes s tanos entresuelos cobertizos o en otros espacios parcialmente cerrados a n si utiliza ventiladores o deja las puertas y ventanas abiertas para favorecer la ventilaci n El mon xido de carbono puede acumularse r pidamente en estos espacios y perdurar ah durante horas aun despu s de que este producto se haya apagado SIEMPRE coloque este producto en direcci n del viento y dirija el escape del motor en sentido contrario a los espacios habitados Si comienza a sentirse mal mareado o d bil cuando use este producto ap guelo y busque aire puro DE INMEDIATO Acuda a un m dico Es posible que se haya envenenado con mon xido de carbono 6 Arranque el generador como se describe en la secci n Arranque del motor y c bralo con la caja de cart n Deje un espacio m nimo de 1 5 cm 5 pies alrededor del generador incluida la parte superior de la estructura de protecci n N ADVERTENCIA Los gases y el calor de escape podr an inflamar los materiales A combustibles y las estructuras o da ar lt S el dep sito de combustible y provocar incendios as como lesiones graves o incluso la muerte El con
20. f brica relleno de aceite API SJ o m s alto 10W 30 Esto permite al generador operar en una gran variedad de condiciones clim ticas y de temperatura Antes de arrancar el motor compruebe el nivel de aceite y aseg rese de que el motor est servido tal como se describe en Mantenimiento AVISO Si intenta arrancar el motor sin comprobar que est adecuadamente servido con el aceite recomendado podr a una aver a Consultar la secci n Mantenimiento acerca del rellenado de aceite a garant a quedar anulada si se producen da os como consecuencia del incumplimiento de estas instrucciones AVISO Consulte la secci n Aceite en la secci n Mantenimiento para ver las recomendaciones relativas al aceite Compruebe que la aceite suministrada tiene la viscosidad adecuada para la temperatura ambiente actual Agregue combustible El combustible debe reunir los siguientes requisitos Gasolina sin plomo limpia y nueva Un m nimo de 87 octanos 87 AKI 91 RON Para uso a gran altitud consulte Gran altitud e Se puede usar gasolina con un contenido de hasta 10 de etanol gasohol AVISO El uso de combustibles no aprobados podr a da ar el generador y anula la garant a NO utilice gasolina no aprobada como E15 y E85 NO mezcle aceite con gasolina ni modifique el motor para hacerlo funcionar con otros combustibles N ADVERTENCIA El combustible y sus vapores son JN extremadamente inflamables y explosivos lo
21. for the exhaust system installed on this engine Replacement parts must be the same and installed in the same position as the original parts A WARNING Unintentional sparking could cause fire or Ia electric shock resulting in death or serious AA XN injury WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester DO NOT check for spark with spark plug removed WARNING Starter and other rotating parts could entangle hands hair clothing or accessories y resulting in serious injury NEVER operate generator without protective housing or covers DO NOT wear loose clothing jewelry or anything that could be caught in the starter or other rotating parts Tie up long hair and remove jewelry A CAUTION Excessively high operating speeds could result in minor injury Excessively low speeds impose a heavy load DO NOT tamper with governor spring links or other parts to increase engine speed Generator supplies correct rated frequency and voltage when running at governed speed DO NOT modify generator in any way NOTICE Exceeding generators wattage amperage capacity could damage generator and or electrical devices connected to it DO NOT exceed the generator s wattage amperage capacity See Don t Overload Generator in the Operation secti
22. fuel evaporate before starting engine Building a Cold Weather Shelter 1 Using non combustible material with a fire rating of at least one hour build a shelter that will enclose three sides and the top of the generator Make sure muffler side of generator is exposed NOTICE Contact your local building material supplier for non combustible materials with a fire rating of at least one hour NOTICE Be sure shelter can easily be repositioned for change in wind direction 2 DO NOT enclose generator any more than shown Shelter should hold enough heat created by the generator to prevent icing problem NOTICE If a wheel kit is installed on the generator enlarge shelter accordingly 3 Follow steps 3 through 8 as described previously in Creating a Temporary Cold Weather Shelter 19 Don t Overload Generator Capacity You must make sure your generator can supply enough rated running and surge starting watts for the items you will power at the same time Follow these simple steps 1 Select the items you will power at the same time 2 Total the rated running watts of these items This is the amount of power your generator must produce to keep your items running See Wattage Reference Guide 3 Estimate how many surge starting watts you will need Surge wattage is the short burst of power needed to start electric motor driven tools or appliances such as a circular saw or refrigerator Because not all motors start at
23. hoses belts connectors sensors and other emissions related assemblies Your evaporative emission control system may include parts such as carburetors fuel tanks fuel lines fuel caps valves canisters filters vapor hoses clamps connectors and other associated components Where a warrantable condition exists B amp S will repair your engine equipment at no cost to you including diagnosis parts and labor Manufacturer s Warranty Coverage Small off road engines and large spark ignited engines less than or equal to 1 0 liter and any emissions related components of the equipment are warranted for two years If any emissions related part on your engine equipment is defective the part will be repaired or replaced by B amp S Two years or for the time period listed in the respective engine or product warranty statement whichever is greater Owner s Warranty Responsibilities As the engine equipment owner you are responsible for the performance of the required maintenance listed in your owner s manual B amp S recommends that you retain all receipts covering maintenance on your engine equipment but B amp S cannot deny warranty solely for the lack of receipts or your failure to ensure the performance of all scheduled maintenance As the engine equipment owner you should however be aware that B amp S may deny you warranty coverage if your engine equipment or a part has failed due to abuse neglect improper maintenanc
24. instructions Smoke alarms cannot detect carbon monoxide gas DO NOT run this product inside homes garages basements crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even after this product has shut off ALWAYS place this product downwind and point the engine exhaust away from occupied spaces If you start to feel sick dizzy or weak while using this product shut it off and get to fresh air RIGHT AWAY See a doctor You may have carbon monoxide poisoning 6 Start generator as described in the section Starting the Engine then place carton over generator Keep at least 5 ft 1 5 m clearance on all sides of generator including overhead with shelter in place N WARNING Exhaust heat gases could ignite A HN combustibles structures or damage fuel la JN tank causing a fire resulting in death or serious injury Contact with muffler area could cause burns resulting in serious injury DO NOT touch hot parts and AVOID hot exhaust gases Allow equipment to cool before touching Keep at least 5 feet 1 5 m of clearance on all sides of generator including overhead Remove shelter when temperatures are above 40 F 4 C 7 Remove shelter when temperatures are above 40 F 4 C 8 Turn engine OFF and let cool two 2 minutes before refueling Let any spilled
25. la velocidad del motor El generador suministra la frecuencia y el voltaje nominales correctos cuando funciona a una velocidad controlada NO modifique al generador en ninguna forma troybilt com Almacenamiento El generador deber ser encendido al menos una vez cada siete d as y deber dejarlo funcionar al menos durante 30 minutos Si no puede hacer esto y debe almacenar la unidad por m s de 30 d as siga las siguientes instrucciones para preparar su unidad para almacenamiento Generador 1 Limpie el generador como est descrito en Limpieza en la secci n Mantenimiento 2 Revise que las ranuras para el aire de enfriamiento y las aperturas del generador se encuentren abiertas y despejadas Almacenamiento para periodos prolongados El combustible puede haberse echado a perder si se ha almacenado por m s de 30 d as El combustible echado a perder provoca la formaci n de residuos cidos y de carbonilla en el sistema de combustible y en los componentes b sicos del carburador Para mantener el combustible en buen estado use Briggs Stratton Advanced Formula Fuel Treatment amp Stabilizer disponible donde sea que se vendan piezas de servicio originales de Briggs amp Stratton Para motores equipados con un tap n de combustible FRESH START use Briggs Stratton FRESH START disponible en un cartucho concentrado de goteo No es necesario vaciar el motor de gasolina si se a ade estabilizador de combustibl
26. las garant as sin fecha y a las de fecha anterior al 1 de noviembre de 2012 GARANT A LIMITADA Troy Bilt es una marca registrada de MTD Products Inc bajo licencia de Briggs amp Stratton Power Products Briggs amp Stratton Power Products Group LLC reparar o sustituir sin cargo alguno cualquier componente del generador port til que presente defectos de materiales y o mano de obra Los gastos de transporte de las producto enviadas para reparar o sustituir conforme a los t rminos de esta garant a correr n a cargo del comprador El periodo de vigencia y las condiciones de esta garant a son los que se estipulan a continuaci n Para obtener servicio en garant a localice el distribuidor de servicio autorizado m s pr ximo en nuestro mapa de distribuidores en www BRIGGSandSTRATTON COM No existe ninguna otra garant a expl cita Las garant as impl citas incluidas las de comerciabilidad o idoneidad para un fin en particular se limitan a un a partir de la fecha de compra o al limite de tiempo permitido por la ley Queda excluida cualquier otra garant a impl cita Queda excluida la responsabilidad por dafios secundarios y derivados hasta el limite permitido por la ley Algunos pa ses o estados no permiten limitar la duraci n de una garant a impl cita ni excluir o limitar los dafios secundarios y derivados Por tanto es posible que las limitaciones y exclusiones mencionadas no sean aplicables en su caso Esta garant a le otorg
27. m clearance from any combustibles or structures including overhead 319066 Espafiol A WARNING Failure to read and L follow the operator s manual all warnings and operating instructions could result in death or serious injury Poisonous Gas Hazard Engine exhaust contains carbon monoxide a poisonous gas that could kill you in minutes You CANNOT smell it see it or taste it Operate this product ONLY outside far away from windows doors and vents Install battery operated carbon monoxide alarms in home Fire Hazard Fuel and its vapors are flammable which could cause burns resulting in death or serious injury Turn engine off and let it cool at least 2 minutes before refueling Never add fuel to a hot or running generator Shock Hazard Generator voltage could cause electrical shock resulting in death or serious injury Transfer switch must be used when connecting to a building s electrical system Do not run generator in rain or wet weather Burn Hazard 2 Muffler area could af cause burns Do not touch hot parts Avoid hot exhaust gases 319064 troybilt com Descripci n del equipo aH Lea atentamente este manual y familiar cese con EI el generador Conozca sus aplicaciones limitaciones y riesgos Este generador funciona en base a un motor de campo el ctrico giratorio y de corriente alterna CA F
28. modelo de motor de gasolina est indicado en una etiqueta conforme al c digo J1940 Procedimiento de valoraci n de potencia y par de torsi n para motores peque os de la Society of Automotive Engineers Sociedad de Ingenieros de Automoci n SAE y se ajusta conforme al c digo SAE J1995 Los valores de par de torsi n se obtienen a 2600 RPM para los motores con indicaci n de rpm en la etiqueta y a 3060 RPM para todos los dem s los valores de potencia se obtienen a 3600 RPM Las curvas de potencia bruta se pueden ver en www BRIGGSandSTRATTON COM Los valores de potencia neta se obtienen con el escape y filtro de aire instalados mientras que los valores de potencia bruta se obtienen sin estos elementos La potencia bruta real del motor es superior a la potencia neta del motor y depende entre otros factores de las condiciones ambientales de uso y de las variaciones entre distintos motores del mismo modelo Dada la amplia variedad de productos que utilizan nuestros motores es posible que el motor de gasolina no desarrolle la potencia bruta nominal en determinados equipos Esta diferencia se debe a los siguientes factores entre otros variedad de componentes del motor filtro de aire escape carga refrigeraci n carburador bomba de combustible etc limitaciones de la aplicaci n condiciones ambientales de uso temperatura humedad altitud y variaciones entre distintos motores de un mismo modelo Debido a limitaciones de fabricaci n y capacid
29. puerta cualquier abertura en la pared arbusto o vegetaci n que tenga m s de 12 pulgadas 30 5 cm de altura NO coloque el generador port til bajo una plataforma u otro tipo de estructura que pueda limitar el flujo de aire Las alarmas de humo SE DEBEN instalar bajo techo y su mantenimiento se debe realizar en las mismas condiciones de acuerdo con las instrucciones recomendaciones del fabricante Las alarmas de mon xido de carbono no pueden detectar el humo NO coloque el generador port til de una manera diferente a la mostrada EJEMPLO DE UBICACI N PARA REDUCIR EL RIESGO DE INCENDIOS 4 5 ft 1 5 m La direcci n del escape debe seren amp sentido contrario a los espacios habitados 14 troybilt com Controles y caracteristicas Lea este manual del operario y reglas de seguridad antes de poner en marcha su generador L Compare las ilustraciones con su generador para familiarizarse con la ubicaci n de los diversos controles y ajustes Guarde este manual para futuras consultas A Disyuntores CA Las tomas dobles de 120 V CA y 20 A disponen de disyuntores de rearme por presi n que protegen al generador contra sobrecargas el ctricas B Tapa del dep sito del aceite Llene el motor con aceite aqu Tap n de vaciado de aceite Permite vaciar el aceite del motor D Conector de tierra Consulte con el organis
30. stated above Consumer Use means personal residential household use by a retail consumer Commercial Use means all other uses including use for commercial income producing or rental purposes Once equipment has experienced commercial use it shall thereafter be considered as commercial use for purposes of this warranty Equipment used for prime power in place of utility are not applicable to this warranty NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS amp STRATTON PRODUCTS SAVE YOUR PROOF OF PURCHASE RECEIPT IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD ABOUT YOUR WARRANTY We welcome warranty repair and apologize to you for being inconvenienced Any Authorized Service Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may not be appropriate For example warranty service would not apply if equipment damage occurred because of misuse lack of routine maintenance shipping handling warehousing or improper installation Similarly the warranty is void if the manufacturing date or the serial number on the portable generator has been removed or the equipment has been altered or modified During the warranty period the Authorized Service Dealer at its option will repair or replace any part that upon examination is f
31. the same time total surge watts can be estimated by adding only the item s with the highest additional surge watts to the total rated watts from step 2 Example Tool or Appliance Watts Starting Watts Window Air 1200 1800 Conditioner Refrigerator 800 1600 Deep Freezer 500 500 Television 500 Light 75 Watts 75 3075 Total 1800 Highest Running Watts Surge Watts Total Rated Running Watts 3075 Highest Additional Surge Watts 1800 Total Generator Output Required 4875 Power Management To prolong the life of your generator and attached devices it is important to take care when adding electrical loads to your generator There should be nothing connected to the generator outlets before starting its engine The correct and safe way to manage generator power is to sequentially add loads as follows 1 With nothing connected to the generator start the engine as described in this manual 2 Plug in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load 20 NEVER add more loads than the generator capacity Take special care to consider surge loads in generator capacity as described above Rated Running Additional Surge Tool or Ap
32. to look far to find Briggs amp Stratton support and service for your generator Consult your Yellow Pages There are over 30 000 Briggs amp Stratton authorized service dealers worldwide who provide quality service You can also contact Troy Bilt Customer Service by phone at 888 611 6708 or on the Internet at www troybilt com Generator Model Number TT LLELLI Revision EN Serial Number Engine Model Number Type Number T EN Date Purchased Copyright 2013 Briggs amp Stratton Power Products Group LLC Milwaukee WI USA All rights reserved TROY BILT is a registered trademark of MTD Used under license 2 troybilt com Safe Operation Checklist Safe operation of the portable generator requires the completion of the following tasks Carbon Monoxide CO Alarm O Carbon monoxide CO alarm s in working order Smoke Alarm O Smoke alarm s in working order Generator Location O Generator placed in a Carbon Monoxide CO safe zone See Generator Location to reduce the Risk of Carbon Monoxide Poisoning O Generator placed in a fire safe zone See Generator Location to reduce the Risk of Fire O Generator located on flat and level surface Oil and Fuel O Engine has proper oil level See Verify Engine Oil Level O Fuel tank filled at or below baffle See Add Fuel O Inspect fuel lines tank cap and fittings each time before using generator DO NOT use if fuel leak or damage is found Electrical O When
33. Conexi n mal o defectuosa del 2 pero no existe salida de AC juego de cables disponsible El dispositivo conectado est 3 da ado Aver a en el generador Corto circuito en una de las cargas 1 El motor funciona bien sin carga pero funciona mal El generador esta sobrecarga cuando se le contectan cargas 3 Velocidad del motor es muy lenta Circuito del generador en corto A ow N V lvula del combustible en posici n Off Interruptor del motor poscioando 2 en OFF o O Nivel de aceite insuficiente 3 Depurador de aire sucio 4 Sin combustible 5 Combustible vieja 6 El motor no se enciende se enciende y funciona El cable de la buj a no est en 7 mal se pleno malas bujia funcionamiento Bujia defectuosa 8 Agua en la combustible 9 Sobrecebado 10 Mezcla de combustible 11 excesivamente rica La v lvula de entrada est 12 atascada est cerrada El motor ha perdido compresi n 13 El motor no funciona _ Carburador con mezcla de aire continuamente o se detiene combustible muy rica o muy pobre Contacte el distribuidor de servicio autorizado Contacte el distribuidor de servicio autorizado Gire la v lvula del combustible a la posici n On Coloque del interruptor en ON o Llene el c rter hasta el nivel correcto o sit e el generador en una superficie plana Limpie o reemplace el depurad
34. N 2 Let engine run at no load for several minutes to stabilize internal temperatures of engine and generator 3 Push engine switch to OFF 0 position N WARNING Fuel and its vapors are extremely flammable J N and explosive which could cause burns fire P N d y or explosion resulting in death or serious injury DO NOT stop engine by moving choke lever to Choke position ID 4 Move fuel valve to Off position Low Oil Shutdown If the engine oil drops below a preset level an oil switch will stop the engine Check oil level with dipstick If oil level is between ADD and FULL mark on dipstick 1 DO NOT try to restart the engine 2 Contact an Authorized Briggs amp Stratton Service Dealer 3 DO NOT operate engine until oil level is corrected If oil level is below ADD mark on dipstick 1 Add oil to bring level to FULL mark 2 Restart engine and if the engine stops again a low oil condition may still exist DO NOT try to restart the engine 3 Contact an Authorized Briggs amp Stratton Service Dealer 4 DO NOT operate engine until oil level is corrected Cold Weather Operation Under certain weather conditions temperatures below 40 F 4 C combined with high humidity your generator may experience icing of the carburetor and or the crankcase breather system To reduce this problem you need to perform the following 1 Make sure generator has clean fresh fuel 2 Open fuel valve turn valve
35. OTROY BILT Portable Generator Operator s Manual This generator is rated in accordance with CSA Canadian Standards Association standard C22 2 No 100 04 motors and generators and PGMA Portable Generator Manufacturers Association standard PGMA G200 Standard for Testing and Validating Performance of Portable Generators BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC MILWAUKEE WISCONSIN U S A Manual No 318797 Revision B Thank you for purchasing this quality built Troy Bilt generator We are pleased that you ve placed your confidence in the Troy Bilt brand When operated and maintained according to the instructions in this manual your Troy Bilt generator will provide many years of dependable service This manual contains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intended only for supplying electrical power for operating compatible electrical lighting appliances tools and motor loads and is not intended for any other purpose It is important that you read and understand these instructions thoroughly before attempting to start or operate this equipment Save these original instructions for future reference This generator requires final assembly before use Refer to the Assembly section of this manual for instructions on final assembly procedures Follow the instructions completely Where to Find Us You never have
36. a del circuito de tierra GFCI en cualquier rea bastante h meda o que sea altamente conductiva tales como terrazas de metal o trabajo hecho con acero NO toque los alambres pelados o recept culos NO use un generador con cables el ctricos que est n malgastados rotos pelados o dafiados de cualquier forma NO opere el generador bajo la lluvia NO maneje el generador o cables el ctricos mientras est parado en agua descalzo o cuando las manos y los pies est n mojados NO permita que personas descalificadas o ni os operen o sirvan al generador A ADVERTENCIA Las chispas involuntarias podr an IAN A provocar incendios o electrocuci n que G amp S pueden provocar lesiones graves la muerte CUANDO AJUSTE O HAGA REPARACIONES A SU M QUINA GENERADOR Siempre desconecte el alambre de la buj a y col quelo donde no pueda entrar en contacto con la buj a CUANDO PRUEBE LA BUJ A DEL MOTOR Utilice un comprobador de buj as homologado NO comprueba la chispa sin la buj a instalada N PRECAUCI N Las velocidades de funcionamiento excesivamente altas podr an provocar lesiones leves Las velocidades excesivamente bajas incrementan la carga de trabajo NO intente alterar el resorte las conexiones y otras partes del regulador para incrementar la velocidad del motor El generador suministra la frecuencia y el voltaje nominales correctos cuando funciona a una velocidad controlada NO modifique al generad
37. a determinados derechos legales y es posible que tenga otros derechos que pueden variar de un pa s o estado a otro PER ODO DE GARANT A Uso del consumidor 2 a ios Uso comercial 1 ano Segundo despide s lo En Australia Nuestros bienes incluyen garant as que no pueden excluirse bajo la Ley del consumidor australiana Usted tiene derecho a una sustituci n del producto o devoluci n de su dinero debido a un fallo importante y como compensaci n por cualquier otra p rdida o dafio razonablemente previsible Tambi n tiene derecho a que se reparen o reemplacen los bienes si estos no cumplen con una calidad aceptable y si el fallo no se considera un fallo importante Para recibir el servicio en garant a localice el distribuidor de servicio autorizado m s pr ximo en nuestro mapa de distribuidores en BRIGGSandSTRATTON COM o bien llame al 1300 274 447 env e un correo electr nico o escriba a salesenquires briggsandstratton com au Briggs amp Stratton Australia Pty Ltd 1 Moorebank Avenue NSW Australia 2170 El per odo de garant a comienza en la fecha de compra del primer usuario final y se prolonga durante el tiempo especificado Uso del consumidor significa uso dom stico personal por parte de un consumidor final Uso comercial significa cualquier otro uso incluidos los usos con fines comerciales de generaci n de ingresos o alquiler Una vez que el equipo se haya usado con fines comerciales se considerar como equip
38. ad Briggs amp Stratton puede sustituir un motor de una potencia nominal mayor por este motor Este generador est clasificado conforme a la norma C22 2 N 100 04 motores y generadores de la Asociaci n Canadiense de Normas Canadian Standards Association CSA y la norma PGMA G200 norma para la evaluaci n y validaci n del rendimiento de los generadores port tiles de la Asociaci n de Fabricantes de Generadores Port tiles Portable Generator Manufacturers Association PGMA Briggs amp Stratton Power Products Group LLC P 0 Box 702 Milwaukee Wisconsin 53201 0702 U S A 30 888 611 6708 troybilt com
39. ado conforme a la norma C22 2 N 100 04 motores y generadores de la Asociaci n Canadiense de Normas Canadian Standards Association CSA y la norma PGMA G200 norma para la evaluaci n y validaci n del rendimiento de los generadores port tiles de la Asociaci n de Fabricantes de Generadores Port tiles Portable Generator Manufacturers Association PGMA BRIGGS amp STARTTON POWER PRODUCTS GROUP LLC MILWAUKEE WISCONSIN U S A Muchas gracias por comprar este generador Troy Bilt de gran calidad Nos alegra que haya depositado su confianza en la marca Troy Bilt Siempre que sea utilizado de acuerdo con las instrucciones de este manual su generador Troy Bilt le proporcionar muchos afios de buen funcionamiento Este manual contiene informaci n sobre seguridad para hacerle consciente de los riesgos asociados a los generadores y mostrarle c mo evitarlos Este generador se ha disefiado exclusivamente para suministrar energ a el ctrica a cargas compatibles de iluminaci n electrodom sticos herramientas y motores No debe utilizarse para ning n otro fin Es importante leer detenidamente y comprender estas instrucciones antes de poner en marcha o utilizar el equipo Conserve este manual original para futuras consultas Este generador requiere montaje final antes de ser usado Consulte la secci n Montaje de este manual donde encontrar instrucciones para el montaje final Siga las instrucciones al pie de la letra D nde encontrarn
40. ador sobre una superficie nivelada 2 Retire la varilla de medici n y limpie la varilla de medici n Instale el varilla de medici n Quite y verifique nivel del aceite AVISO NO enrosque la varilla de nivel de aceite cuando la inserte para comprobar el nivel de aceite 3 Compruebe que el aceite hasta la marca Full D de la varilla de medici n Instale el varilla de medici n apriete firmemente Adici n de aceite del motor 1 Coloque el generador sobre una superficie nivelada 2 Compruebe el nivel de aceite tal como se indica en la secci n Comprobaci n del nivel de aceite 3 Si es necesario vierta lentamente aceite por el orificio de llenado hasta la marca Full de la varilla de medici n NO llene excesivamente AVISO El llenado de aceite en exceso podr a impedir el arranque del motor o provocar dificultades de arranque NO llene en exceso e Si el nivel de aceite est por encima de la marca FULL LLENO de la varilla vac e aceite para reducir el nivel hasta la marca FULL LLENO de la varilla 4 Instale el varilla de medici n apriete firmemente troybilt com Cambio de aceite del motor Si esta utilizando su generador bajo condiciones de extrema suciedad o polvo o en un clima demasiado caliente haga el cambio de aceite m s frecuentemente A PRECAUCI N Evite el contacto prolongado o repetido de piel con aceite usado de motor El aceite usado del motor ha sido mostrado al cancer
41. alrededor del generador incluida la parte superior Utilizar el motor en un terreno boscoso con maleza o cubierto de hierba constituye una infracci n al C digo de recursos p blicos de California a menos que el sistema de escape est equipado con una pantalla apagachispas de acuerdo a la definici n de la Secci n 4442 que se mantenga en buenas condiciones de funcionamiento En otros estados o jurisdicciones federales puede haber leyes similares en vigor P ngase en contacto con el fabricante el vendedor o el distribuidor del equipo original para obtener una pantalla apagachispas dise ada para el sistema de escape instalado en este motor Las piezas de recambio deben ser las mismas que las piezas originales y estar instaladas en la misma posici n Espa ol Conexi n de cargas el ctricas 1 Deje que el motor se estabilice y se caliente por dos minutos despu s del arranque 2 Aseg rese de que el disyuntor basculante est en la posici n ON o Encendido 3 Ench felo y encienda la carga el ctrica deseada 120 y o 240 V CA monof sico 60 Hz AVISO Si conecta aparatos a las tomas de 120 V h galo en la secuencia que se muestra a continuaci n AVISO NO conectar cargas de 240 V en las tomas el ctricas dobles NO conectar cargas trif sicas al generador NO conectar cargas de 50 Hz al generador NO SOBRECARGAR EL GENERADOR V ase No sobrecargar el generador AVISO El sobrepasar la
42. ape del generador contienen monoxido de carbono un veneno invisible e inodoro NUNCA utilice un generador Utilicelo solo en el en el interior de una casao EXTERIOR alejado de un garaje AUNQUE haya ventanas puertas y ventanas y puertas abiertas aberturas de ventilaci n En muchos estados por ley es necesario que en los hogares se cuente con una alarma A de mon xido de carbono CO en funcionamiento Instale mantenga alarmas de mon xido de carbono de bater as o enchufables con respaldo de bater a de acuerdo con las instrucciones del fabricante Una alarma de CO es un dispositivo electr nico que detecta niveles peligrosos de CO Cuando hay acumulaci n de CO la alarma alerta a los ocupantes con una luz indicadora visual centellante y una alarma Las alarmas de humo no pueden detectar el gas CO Utilice este producto NICAMENTE a la intemperie lejos de ventanas puertas y ventilaciones para reducir el riesgo de que el gas de mon xido de carbono se acumule y entre en los espacios habitados NO utilice este producto dentro de casas garajes s tanos entresuelos cobertizos o en otros espacios parcialmente cerrados a n si utiliza ventiladores o deja las puertas y ventanas abiertas para favorecer la ventilaci n El mon xido de carbono puede acumularse r pidamente en estos espacios y perdurar ah durante horas aun despu s de que este producto se haya apagado Las casas vecinas puede quedar expuesta a l
43. ar en una superficie plana y nivelada Aceite y combustible O El motor debe tener el nivel adecuado de aceite Consulte Comprobaci n del nivel de aceite del motor L1 El tanque de combustible se debe llenar hasta el deflector o por debajo de l Consulte Adici n de combustible L1 Inspeccione siempre las l neas el tanque el tap n y los accesorios de combustible antes de usar el generador NO lo use si detecta fugas de combustible o da o Sistema el ctrico O Cuando realice conexiones al sistema el ctrico de un edificio instale el equipo de transferencia indicado Consulte Conexi n al sistema el ctrico de un edificio L1 Los valores nominales de los cables el ctricos deben ser las adecuadas para las cargas deseadas Consulte Juegos de cables y tomas el ctricas O Los cables el ctricos no se deben extender a trav s de puertas ventanas orificios en techos paredes o pisos O Inspeccione los cables el ctricos perfectamente antes de usarlos NO los use si est n da ados O Es necesario entender y seguir todas las indicaciones de seguridad de los cables el ctricos etiquetados Funcionamiento O Arranque el motor Consulte Arranque del motor Espa ol Tabla de Contenido Lista de control para una operaci n segura 3 Tabla de 4 Seguridad de 5 Etiquetas de seguridad kee bee eR Re 5 Descripci n de
44. atios Congelador industrial Bomba para sumideros Refrigerador Congelador 18 pies c bicos Bomba de agua 1 3 HP Calefacci n Aire Acondicionado Aire acondicionado de ventana 10 000 BTU Ventilador de ventana Ventilador de caldera 1 2 HP Horno microondas 1000 vatios Cafetera Estufa el ctrica Elemento simple Plancha de cocina Habitaci n familiar Reproductor de DVD CD C Receptor est reo 20 Televisi n en color 27 Ordenador personal con monitor de 17 Sistema de seguridad Radio reloj AM FM Dispositivo de apertura de garage 1 2 HP Calentador de agua el ctrico 150 litros aprox 40 galones Taller Luz hal gena de cuarzo para trabajar Rociador sin aire 1 3 HP Sierra sable Taladro el ctrico 1 2 HP Sierra Radial 10 Sierra inglete 10 Cepilladora de mesa 6 Sierra de mesa Sierr de brazo radial 10 Compresor de aire 1 1 2 HP La potencia que aparece en la lista es aproximada Compruebe la herramienta o aparato el ctrico para obtener la potencia real troybilt com Mantenimiento Plan de mantenimiento Siga los intervalos de horas o de calendario los que sucedan antes Si opera en condiciones adversas sefialadas m s abajo es necesario un mantenimiento m s frecuente 1 Servicio m s a menudo bajo condiciones de suciedad o polvo Recomendaciones generales El mantenimiento peri dico mejorar e
45. car lesiones graves o la muerte CUANDO AJUSTE 0 HAGA REPARACIONES A SU M QUINA GENERADOR Siempre desconecte el alambre de la buj a y col quelo donde no pueda entrar en contacto con la buj a CUANDO PRUEBE LA BUJ A DEL MOTOR Utilice un comprobador de buj as homologado NO comprueba la chispa sin la buj a instalada Aceite Recomendaciones sobre el aceite Para obtener el mejor rendimiento recomendamos utilizar aceites certificados con garant a Briggs amp Stratton Tambi n se pueden utilizar otros aceites detergentes de alta calidad con clasificaci n de servicio SF SG SH SJ o superior NO utilice aditivos especiales Las temperaturas exteriores determinan la viscosidad adecuada del aceite para el motor Utilice el cuadro para seleccionar la mejor viscosidad para el intervalo de temperatura exterior previsto 22 oF C 104 N 40 86 masc e 30 68 u1 20 50 mau ie 10 32 0 14 HE 10 20 22 A 230 Por debajo de 4 C 40 F el uso de aceite SAE 30 provocar dificultades de arranque Por encima de 27 C 80 F el uso de aceite 10W30 puede aumentar el consumo de aceite Compruebe el nivel de aceite con mayor frecuencia Comprobaci n del nivel de aceite Compruebe el nivel de aceite antes de cada uso o cada 8 horas de funcionamiento como m nimo Rellene si es necesario 1 Coloque el gener
46. connecting to a buildings electrical system install listed transfer equipment See Connecting to a Building s Electrical System O Electrical cords are rated for intended loads See Cord Sets and Receptacles O Electrical cords do not run through doorways windows holes in ceilings walls or floors L1 Inspect electrical cords thoroughly before each use DO NOT use if damaged L1 All labeled electrical cord safeties are understood and being followed Operation L1 Start engine See Starting the Engine Table of Contents Safe Operation 3 Table of 4 Operator 5 Safety Labels CERDO RE d 5 Equipment Description liiis 7 Important Safety 7 Assembly cca kiama daa wo poe eed HR ode wie 10 Unpack hee beg 10 Install Wheel Kites os ecce Raden eem ai e eee 10 Verify Engine Oil Level 0 ccc cece RI 10 ace gp eset dead tac api Were ded dn Shetek de Sods daa des 11 System sir ertet tatc drin 11 Connecting to a Building s Electrical SysteM 11 Portable Generator Location 12 Features and 5 15 Cord Sets and Receptacles
47. d spaces DO NOT run this product inside homes garages basements crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even after this product has shut off Your neighbor s home may be exposed to the engine exhaust from your portable generator and must be considered when deciding on a location for the safe operation of your portable generator ALWAYS place this product downwind and point the engine exhaust away from occupied spaces If you start to feel sick dizzy or weak while using this product shut it off and get to fresh air RIGHT AWAY See a doctor You may have carbon monoxide poisoning 12 troybilt com EXAMPLE OF LOCATION TO REDUCE THE RISK OF CARBON MONOXIDE POISONING ONLY use outside and downwind far away from windows doors and vents Sn Exhaust direction J away from 0 occupied spaces i DO NOT OPERATE IN ANY OF THE FOLLOWING LOCATIONS Carbon Monoxide Alarm Entryway Porch Mud Room Living Area Carbon Monoxide Alarm Basement or Crawl Area Operation Location of Portable Generator to REDUCE THE RISK OF FIRE A WARNING Exhaust heat gases could ignite combustibles structures or damage fuel tank AN causing a fire resulting in death or serious injury Portable generator must be at least
48. de la piel de la causa en ciertos animales del laboratorio Completamente lavado expuso reas con el jab n y el agua MANTENER FUERA DEL ALCANCE DE LOS NINOS NO CONTAMINE CONSERVE LOS RECURSOS DEPOSITE EL ACEITE USADO EN UN PUNTO DE RECOGIDA Cambie el aceite cuando el motor siga estando caliente despu s de haber funcionado 1 Aseg rese de que la unidad est en una superficie plana 2 Desconecte el cable de la buj a de esta y col quelo donde no pueda entrar en contacto con la buj a 3 Limpie la zona de alrededor del tap n de vaciado de aceite A situado en la base del motor al otro lado del carburador 4 Quite el tap n de llenado de aceite y vac e todo el aceite en un recipiente adecuado 5 Vuelva a colocar el tap n de vaciado y apri telo bien Quite la varilla de nivel de aceite 6 Vierta lentamente unos 1 0 litros 36 onzas de aceite por el orificio Deposite el aceite recomendado hasta la marca Full de la varilla de medici n 7 Limpie la varilla de medici n cada vez nivel del aceite se verifica NO a ada aceite en exceso 8 Instale la varilla de medici n apriete firmemente 9 Limpie los residuos de aceite Servicio del depurador de aire Si se utiliza con un filtro de aire sucio el motor no funcionar correctamente y puede sufrir dafios Limpielo 0 reempl celo m s a menudo si la unidad funciona bajo condiciones de suciedad o polvo excesivo Para dar servicio al filtro de
49. der warranty will be warranted for the remaining warranty period Any warranted part that is scheduled for replacement as required maintenance in the owner s manual supplied is warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part will be repaired or replaced by B amp S at no charge to the owner Any such part repaired or replaced under warranty will be warranted for the remainder of the period prior to the first scheduled replacement point for the part Add on or modified parts that are not exempted by the Air Resources Board may not be used The use of any non exempted add on or modified parts by the owner will be grounds for disallowing a warranty claim The manufacturer will not be liable to warrant failures of warranted parts caused by the use of a non exempted add on or modified part 3 Consequential Coverage Coverage shall extend to the failure of any engine components caused by the failure of any warranted emissions parts 4 Claims and Coverage Exclusions Warranty claims shall be filed according to the provisions of the B amp S engine warranty policy Warranty coverage does not apply to failures of emissions parts that are not original equipment B amp S parts or to parts that fail due to abuse neglect or improper maintenance as set forth in the B amp S engine warranty policy B amp S is not liable for warranty cove
50. detallan a continuaci n Desgaste normal Al igual que cualquier otro aparato mec nico los equipos de uso en exteriores necesitan piezas y mantenimiento peri dicos para funcionar correctamente Esta garant a no cubre las reparaciones cuando el uso normal haya agotado la vida til de una pieza concreta del equipo Instalaci n y mantenimiento Esta garant a no cubre los equipos ni las piezas cuya instalaci n sea incorrecta o no haya sido autorizada ni aquellos que hayan sido objeto de cualquier tipo de alteraci n mal uso negligencia accidente sobrecarga exceso de velocidad o mantenimiento reparaci n 0 almacenamiento inadecuados que a nuestro juicio haya afectado negativamente a su funcionamiento y su fiabilidad La garant a tampoco cubre el mantenimiento normal como los filtres de aire los ajustes y la limpieza o la obstrucci n del sistema de combusti n debido a materias qu micas suciedad carb n cal y as sucesivamente Otras exclusiones Tambi n quedan excluidos de esta garant a el desgaste de los art culos tales como juntas t ricas filtros etc o los da os derivados de accidentes uso indebido modificaciones alteraciones servicio inadecuado congelaci n o deterioro qu mico Los accesorios tales como empezar bater as juego de cables del adaptador del generador y cubiertas para almacenamiento quedan excluidos de la garant a del producto Tambi n se excluyen los equipos usados o reacondicionados y los dest
51. dress practices not related to personal injury DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home Only use OUTSIDE and or garage EVEN IF doors far away from windows and windows are open doors and vents A WARNING POISONOUS GAS HAZARD Engine A exhaust contains carbon monoxide a poisonous IAN gas that could kill you in minutes You CANNOT smell it see it or taste it Even if you do not smell exhaust fumes you could still be exposed to carbon monoxide gas Operate this product ONLY outside far away from windows doors and vents to reduce the risk of carbon monoxide gas from accumulating and potentially being drawn towards Occupied spaces Install battery operated carbon monoxide alarms or plug in carbon monoxide alarms with battery back up according to the manufacturer s instructions Smoke alarms cannot detect carbon monoxide gas DO NOT run this product inside homes garages basements crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even after this product has shut off ALWAYS place this product downwind and point the engine exhaust away from occupied spaces If you start to feel sick dizzy or weak while using this product shut it off and get to fresh
52. e or unapproved modifications You are responsible for presenting your engine equipment to a B amp S distribution center servicing dealer or other equivalent entity as applicable as soon as a problem exists The warranty repairs should be completed in a reasonable amount of time not to exceed 30 days If you have any questions regarding your warranty rights and responsibilities you should contact B amp S at 1 800 444 7774 in USA or BRIGGSandSTRATTON COM Briggs amp Stratton Emissions Control Warranty Provisions The following are specific provisions relative to your Emissions Control Warranty Coverage It is in addition to the B amp S engine warranty for non regulated engines found in the Operator s Manual 1 Warranted Emissions Parts Coverage under this warranty extends only to the parts listed below the emissions control systems parts to the extent these parts were present on the B amp S engine and or B amp S supplied fuel system a Fuel Metering System Cold start enrichment system soft choke Carburetor and internal parts Fuel pump Fuel line fuel line fittings clamps Fuel tank cap and tether Carbon canister b Air Induction System Air cleaner ntake manifold Purge and vent line c Ignition System Spark plug s Magneto ignition system d Catalyst System Catalytic converter Exhaust manifold Air injection system or pulse valve e Miscellaneous Items Used in Above Systems Vacuum
53. e 20 Amps Use los juegos de cables que son calificados para cargas de 125 Voltios AC a 20 Amps mayores troybilt com Operando Encienda el motor Desconecte todas las cargas el ctricas del generador Use las siguientes instrucciones para encender 1 Aseg rese de que la unidad est en una superficie plana AVISO Si la unidad no se arranca y utiliza en una superficie plana se pueden producir problemas de arranque y de parada durante el funcionamiento 2 Gire la v lvula del combustible A a la posici n On 3 Mueva la palanca estranguladora B hasta la posici n Choke Estrangular IM 5 Hale la manija de retroceso en forma suave hasta que sienta resistencia Luego para arrancar el motor hacer tracci n en forma r pida una sola vez e Siel motor arranca contin e con el paso 7 e Siel motor no arranca proceda con el paso 6 A ADVERTENCIA El retroceso repliegue r pido del cable y del arrancador impedir que el usuario suelte el A cable a tiempo y tirar de su mano y brazo hacia el motor lo que podr a provocar fracturas contusiones o esguinces as como lesiones graves Cuando arranque el motor tire lentamente del cable hasta sentir una resistencia y a continuaci n tire r pidamente de l para evitar su retroceso NUNCA arranque o pare el motor cuando haya aparatos el ctricos conectados y en funcionamiento 6 Mueva la palanca de choque hasta
54. e conforme a las instrucciones Ponga en funcionamiento el motor durante 2 minutos para que el estabilizador circule por todo el sistema de combustible antes de almacenarlo A ADVERTENCIA El combustible y sus vapores A son extremadamente inflamables explosivos lo que podria quemaduras incendios o explosiones as como lesiones graves o incluso la muerte CUANDO ALMACENE 0 GUARDE EL EQUIPO CON COMBUSTIBLE EN EL TANQUE Almacene alejado de calderas estufas calentadores de agua secadoras de ropa u otros aparatos electrodom sticos que posean pilotos u otras fuentes de ignici n porque ellos pueden encender los vapores de la combustible CUANDO VAC E EL DEP SITO DETENGA el motor del generador y d jelo enfriar durante al menos 2 minutos antes de quitar el tap n de combustible Afloje la tapa lentamente para dejar que la presi n salga del tanque Vac e el dep sito de combustible a la intemperie Mantenga la combustible alejada de chispas llamas abiertas pilotos calor y otras fuentes de ignici n Compruebe frecuentemente que las l neas de combustible el tanque el tap n y los accesorios no est n rotos o tengan fugas C mbielos si es necesario NO encienda un cigarrillo o fume Si no se ha afiadido un estabilizador de combustible a la gasolina deber vaciar completamente el motor utilizando un contenedor homologado Deje funcionar el motor hasta que se agote el combustib
55. e cover on the equipment 4 Store generator in clean dry area 25 Troubleshooting One of the circuit breakers is open Engine is running but no AC Fault in generator output is available Poor connection or defective cord set Connected device is bad Short circuit in a connected load Engine speed is too slow Generator is overloaded Shorted generator circuit Engine runs well at no load but bogs down when loads are connected Engine switch set to off position 0 Fuel valve is in Off position Low oil level Dirty air cleaner Out of fuel Stale fuel Engine will not start starts and runs rough or shuts down when Spark plug wire not connected to spark running plug Bad spark plug Water in fuel Hooded Excessively rich fuel mixture Intake valve stuck open or closed Engine has lost compression Problem Cause Correction Reset circuit breaker Contact authorized service facility Check and repair Connect another device that is in good condition Disconnect shorted electrical load Contact authorized service facility See Don t Overload Generator Contact authorized service facility Set switch to on position I Turn fuel valve to On position Fill crankcase to proper level or place generator on level surface Clean or replace air cleaner 5 Fill fuel tank Drain fuel tank and carburetor fi
56. e extent permitted by law All other implied warranties are excluded Liability for incidental or consequential damages are excluded to the extent exclusion is permitted by law Some states or countries do not allow limitations on how long an implied warranty lasts and some states or countries do not allow the exclusion or limitation of incidental or consequential damages so the above limitation and exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state or country to country WARRANTY PERIOD Consumer Use 2 years Commercial Use 1 year Second year parts only n Australia Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure For warranty service find the nearest Authorized Service Dealer in our dealer locator map at BRIGGSandSTRATTON COM or by calling 1300 274 447 or by emailing or writing to salesenquires briggsandstratton com au Briggs amp Stratton Australia Pty Ltd 1 Moorebank Avenue NSW Australia 2170 The warranty period begins on the date of purchase by the first retail end user and continues for the period of time
57. e todas las medidas de seguridad de los cables el ctricos Examine los juegos de cables antes de cada uso Dispositivo de seguridad de 120 240 V 30 A Use un tap n NEMA L14 30 con este recept culo Conecte un juego de cable de 4 alambres clasificado como 250 Voltios AC a 30 Amps o mayor Usted puede usar el mismo cable de 4 alambres si planea trabajar con una carga de 120 Voltios Juego de cable de 4 alambres 240V 20V W Neutro bo Y Cargado X Cargado NEMA L14 30 4 Tierra Verde Este receptaculo le provee poder a cargas de 120 240 Voltios AC de 60 Hz fase sencilla que requieren hasta 3 125 vatios de energia a 26 0 Amperios para 120 Voltios 6 250 vatios de energ a 6 25 kW a 26 0 Amperios para 240 Voltios El enchufe est protegido por un disyuntor basculante AVISO Las tomas el ctricas pueden marcar un valor nominal mayor que la capacidad de salida del generador NUNCA intente conectar un dispositivo que requiera m s amperaje del que el generador o la toma el ctrica pueden suministrar NO sobrecargar el generador V ase Vo sobrecargar el generador 16 Tomas el ctricas dobles de 120 V CA y 20 A El generador tiene dos tomas dobles de 120 V y 20 A Cada toma est protegida contra sobrecargas por medio de disyuntores de rearme por presi n Use cada recept culo para operar 120 Voltios AC de fase sencilla de cargas de 60Hz que requieren hasta 2 400 vatios 2 4 kW a corrientes d
58. ecommended replacement spark plug See Specifications 5 Install spark plug and tighten firmly 23 Inspect Muffler and Spark Arrester The engine exhaust muffler has a spark arrester screen Inspect the muffler for cracks corrosion or other damage Remove the spark arrester and inspect for damage or carbon blockage If replacement parts are required make sure to use only original equipment replacement parts A WARNING Exhaust heat gases could ignite combustibles structures or damage fuel tank E5 causing a fire resulting in death serious injury and or property damage Contact with muffler area could cause burns resulting in serious injury DO NOT touch hot parts and AVOID hot exhaust gases Allow equipment to cool before touching Keep at least 5 feet 1 5 m of clearance on all sides of generator including overhead It is a violation of California Public Resource Code Section 4442 to use or operate the engine on any forest covered brush covered or grass covered land unless the exhaust system is equipped with a spark arrester as defined in Section 4442 maintained in effective working order Other states or federal jurisdictions may have similar laws Contact the original equipment manufacturer retailer or dealer to obtain a spark arrester designed for the exhaust system installed on this engine Replacement parts must be the same and installed in the same position as the original parts Clean and inspec
59. el generador o cables el ctricos mientras est parado en agua descalzo o cuando las manos y los pies est n mojados NO permita que personas descalificadas o ni os operen o sirvan al generador Ubicaci n del generador port til Antes de arrancar el generador port til hay dos consideraciones de seguridad que deben atenderse que tienen igual importancia respecto al envenenamiento por mon xido de carbono CO y a los incendios AVISO Cumplir con los requisitos de ubicaci n relacionados con el RIESGO DE ENVENENAMIENTO POR MON XIDO DE CARBONO podr a no cumplir con los requisitos de ubicaci n para evitar incendios Cumplir con los requisitos de ubicaci n relacionados con el RIESGO DE INCENDIOS podr a no cumplir con los requisitos de ubicaci n para evitar ENVENENAMIENTO POR MON XIDO DE CARBONO Ubicaci n de operaci n del generador port til para REDUCIR EL RIESGO DE ENVENENAMIENTO POR MONOXIDO DE CARBONO Todo equipo que quema combustible f sil como un generador port til contiene gas mon xido de carbono CO en el escape del motor un gas venenoso que podr a matarlo en minutos NO tiene olor color ni sabor Aunque no pueda oler los vapores del escape podr a estar expuesto al gas mon xido de carbono Lo siguiente debe completarse antes de arrancar el motor del generador port til 12 PELIGRO El uso de generador en un espacio interior PUEDE PROVOCAR LA MUERTE EN POCOS MINUTOS Los gases de esc
60. emaduras y lesiones graves NO toque las superficies calientes y EVITE los gases del escape a alta temperatura Permita que el equipo se enfr e antes de tocarlo Deje un espacio m nimo de 1 5 m 5 pies alrededor del generador incluida la parte superior Utilizar el motor en un terreno boscoso con maleza o cubierto de hierba constituye una infracci n al C digo de recursos p blicos de California a menos que el sistema de escape est equipado con una pantalla apagachispas de acuerdo a la definici n de la Secci n 4442 que se mantenga en buenas condiciones de funcionamiento En otros estados o jurisdicciones federales puede haber leyes similares en vigor P ngase en contacto con el fabricante el vendedor o el distribuidor del equipo original para obtener una pantalla apagachispas dise ada para el sistema de escape instalado en este motor Las piezas de recambio deben ser las mismas que las piezas originales y estar instaladas en la misma posici n A ADVERTENCIA El voltaje del generador podr a AR provocar descargas el ctricas o quemaduras que lt A pueden producir lesiones graves la muerte Utilice los equipos de transferencia indicados ideales para el uso deseado a fin de evitar la retroalimentaci n ya que se a sla el generador de las personas que trabajan con el suministro el ctrico Si utiliza el generador como sistema de reserva notif quelo a la compa a el ctrica Use un interruptor para la fall
61. emove everything from carton except generator 3 Open carton completely by cutting each corner from top to bottom 4 Leave generator on carton to install wheel kit The generator is supplied with Operator s manual Wheel kit Install Wheel Kit NOTICE Wheels and support leg must be attached prior to adding any fuel NOTICE Wheel kit is not intended for over the road use You will need the following tools to install these components e 13 mm wrenches 2 Pliers e Safety glasses Install the wheel kit as follows 1 Tip generator so that control panel end is down 2 Slide axle A through holes in generator frame LA 10 3 Slide a black nylon washer over axle 4 Slide a wheel C over axle NOTICE Be sure to install wheel with raised hub inboard 5 Slide a flat washer D over axle 6 Place an e ring E in axle groove 7 Install e ring with pliers squeezing from top of e ring to bottom of axle A CAUTION E rings could cause eye injury E rings could spring back and become airborne when installing or removing resulting in moderate injury e Always wear eye protection when installing removing e rings 8 Repeat step 3 thru 7 to secure second wheel 10 Line up holes in support leg F with holes in generator frame 11 Attach support leg using two capscrews G and two hex nuts H Tighten with 13 mm wrenches 12 Repeat s
62. enerator 16 120 Volt AC 20 Amp Duplex Receptacles The generator has two 120 Volt 20 Amp duplex receptacles Each receptacle is protected against overload by push to reset circuit breakers Use each receptacle to operate 120 Volt AC single phase 60 Hz electrical loads requiring up to 2 400 watts 2 4 kW at 20 Amps of current Use cord sets that are rated for 125 Volt AC loads at 20 Amps or greater Inspect cord sets before each use troybilt com Operation 6 Move choke lever to Half choke position and pull recoil handle twice Starting the Engine e f engine fails to start repeat steps 5 thru 7 Disconnect all electrical loads from the generator Use the 7 Slowly move choke lever to Run position 141 If following start instructions engine falters move choke lever to Half choke 1 Make sure unit is on a level surface position until engine runs smoothly and then to Run NOTICE Failure to start and operate the unit on a level position 141 surface will cause the unit not to start or shut down during NOTICE If engine floods place choke lever in Run operation position 1 1 and crank until engine starts 2 Turn the fuel valve A to the On position NOTICE f engine starts after 3 pulls but fails to run or if unit shuts down during operation make sure unit is on a level surface and check for proper oil level in crankcase This unit may be equipped with a low oil protection device If so
63. esistance of these windings Cleaning Daily or before use look around and underneath the generator for signs of oil or fuel leaks Clean accumulated debris from inside and outside the generator Keep the linkage spring and other engine controls clean Keep the area around and behind the muffler free from any combustible debris Inspect cooling air slots and openings on generator These openings must be kept clean and unobstructed Engine parts should be kept clean to reduce the risk of overheating and ignition of accumulated debris Use a damp cloth to wipe exterior surfaces clean NOTICE Improper treatment of generator could damage it and shorten its life DO NOT expose generator to excessive moisture dust dirt or corrosive vapors DO NOT insert any objects through cooling slots Use a soft bristle brush to loosen caked on dirt or oil Use a vacuum cleaner to pick up loose dirt and debris Fuel Valve Maintenance The fuel valve is equipped with a fuel sediment cup screen and o ring that need to be cleaned 1 Move fuel valve to Off position 2 Remove sediment cup A from fuel valve Remove o ring B and screen C from fuel valve 3 Wash sediment cup o ring and screen in a nonflammable solvent Dry them thoroughly 21 4 Place screen and o ring into fuel valve Install sediment cup and tighten securely 5 Move fuel valve to On position and check for leaks Replace fuel valve if t
64. frequently for cracks or leaks Replace if necessary DO NOT light a cigarette or smoke WHEN STARTING EQUIPMENT Ensure spark plug muffler fuel cap and air cleaner are in place e DO NOT crank engine with spark plug removed WHEN OPERATING EQUIPMENT DO NOT operate this product inside any building carport porch mobile equipment marine applications or enclosure DO NOT tip engine or equipment at angle which causes fuel to spill DO NOT stop engine by moving choke control to Choke position IM WHEN TRANSPORTING MOVING OR REPAIRING EQUIPMENT e Transport move repair with fuel tank EMPTY or with fuel shutoff valve OFF DO NOT tip engine or equipment at angle which causes fuel to spill Disconnect spark plug wire WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK Store away from furnaces stoves water heaters clothes dryers or other appliances that have pilot light or other ignition source because they could ignite fuel vapors A WARNING This generator does not meet U S Coast Guard Regulation 33CFR 183 and should not be used on marine applications Failure to use the appropriate U S Coast Guard approved generator could result in death or serious injury and or property damage troybilt com A WARNING Generator voltage could cause electrical A shock or burn resulting in death or serious injury K Use listed transfer equipment suitable for the intended use to prevent backfeed by isolating gene
65. hase 2 or Phase 3 emissions standards The Emissions Compliance Period referred to on the Emissions Compliance label indicates the number of operating hours for which the engine has been shown to meet Federal emissions requirements For engines less than 225 cc displacement Category C 125 hours Category B 250 hours Category A 500 hours For engines of 225 cc or more displacement Category C 250 hours Category B 500 hours Category A 1000 hours troybilt com TROY BILT PORTABLE GENERATOR OWNER WARRANTY POLICY Effective November 1 2012 replaces all undated Warranties and all Warranties dated before November 1 2012 LIMITED WARRANTY Troy Bilt is a registered trademark of MTD Products Inc and is used under license to Briggs amp Stratton Power Products Briggs amp Stratton Power Products Group LLC will repair or replace free of charge any part s of the portable generator that is defective in material or workmanship or both Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser This warranty is effective for the time periods and subject to the conditions stated below For warranty service find the nearest Authorized Service Dealer in our dealer locator map at BRIGGSandSTRATTON COM There is no other express warranty Implied warranties including those of merchantability and fitness for a particular purpose are limited to one year from purchase or to th
66. here is any leakage Engine Maintenance A WARNING Unintentional sparking could cause fire or JX electric shock resulting in death or serious dM CS injury WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester DO NOT check for spark with spark plug removed Oil Oil Recommendations We recommend the use of Briggs amp Stratton Warranty Certified oils for best performance Other high quality detergent oils are acceptable if classified for service SF SG SH SJ or higher DO NOT use special additives Outdoor temperatures determine the proper oil viscosity for the engine Use the chart to select the best viscosity for the outdoor temperature range expected oF 26 104 N 40 86 o 30 68 u al lt 20 50 mmu nun 10 32 3 BM 0 14 E E O E 10 4 e z 20 22 NW JOA 20 Below 40 F 4 C the use of SAE 30 will result in hard starting Above 80 F 27 C the use of 10W30 may cause increased oil consumption Check oil level more frequently 22 Checking Oil Level Oil level should be checked prior to each use or at least every 8 hours of operation Keep oil level maintained 1 Make sure generator is on a level surface 2 Clean area around oil fill remove oil cap dipstick and wipe dips
67. iales e iluminaci n el ctrica de 120 Voltios AC a 20 Amperios monof sica de 60 Hz No mostrado Identificaci n del motor Indica el modelo tipo y c digo del motor Tenga por favor estos prontamente disponible cuando llamar para la ayuda Etiqueta de identificaci n Proporciona el modelo revisi n y el n mero de serie de generador Tenga por favor estos prontamente disponible cu ndo llamar para la ayuda Espa ol 15 Juegos de cordones y enchufes conectores Utilice nicamente cables prolongadores de alta calidad bien aislados y conectados a tierra con las tomas del generador Examine los cables prolongadores antes de cada uso Examine los valores nominales de los cables prolongadores antes de utilizarlos Los juegos de cables prolongadores utilizados deben tener valores nominales para cargas de CA de 20 A o mayores para tomacorrientes dobles o 30 A para recept culo de seguridad Consulte los manuales del operario de dispositivos a los que se les suministra energ a para conocer las recomendaciones del fabricante La unidad incluye un disyuntor basculante bipolar para proteger la toma blocante Si el disyuntor se dispara todas las tomas se desconectan N ADVERTENCIA Los cables el ctricos da ados A Sobrecargados podr an sobrecalentarse y producir arcos y quemaduras lo que provocar a lesiones graves incluso la muerte Utilice exclusivamente cables regulados para las cargas aplicadas Respet
68. ias qu micas declaradas cancer genas causantes de malformaciones y otros defectos cong nitos por el Estado de California L vese las manos despu s de manipular estos elementos A ADVERTENCIA Elescape del motor de este producto contiene elementos qu micos reconocidos en el Estado de California por producir c ncer defectos de nacimiento u otros da os de tipo reproductivo N ADVERTENCIA El retroceso repliegue r pido del cable del arrancador impedir que el usuario suelte el A cable a tiempo y tirar de su mano y brazo hacia el motor lo que podr a provocar fracturas contusiones o esguinces as como lesiones graves Cuando arranque el motor tire lentamente del cable hasta sentir una resistencia y a continuaci n tire r pidamente de l para evitar su retroceso NUNCA arranque o pare el motor cuando haya aparatos el ctricos conectados y en funcionamiento Espa ol A PELIGRO El uso de un generador en un espacio interior PUEDE PROVOCAR LA MUERTE EN POCOS MINUTOS Los gases de escape del generador contienen monoxido de carbono un veneno invisible e inodoro NUNCA utilice un generador Util celo solo en el en el interior de una casao EXTERIOR alejado de un garaje AUNQUE haya ventanas puertas y ventanas y puertas abiertas aberturas de ventilaci n A ADVERTENCIA PELIGRO DE GAS VENENOSO Los A gases del escape del motor contienen mon xido de N carbono un gas venenoso que podr a ma
69. iento 6 Proteja la unidad de la intemperie troybilt com Creaci n de una estructura de protecci n provisional para climas fr os 1 Para estructura de protecci n provisional utilice la caja de cart n de embalaje original 2 Corte las tapas superiores y uno de los laterales largos de la caja de cart n para dejar al descubierto el lado del silenciador de la unidad Si es necesario sujete con cinta adhesiva los otros laterales de la caja de forma que queden sobre el generador como se muestra AVISO Si es necesario quite el juego de ruedas para que el cart n cubra el generador como se muestra 3 Haga los recortes necesarios para poder acceder a las tomas de la unidad 4 Coloque el lado expuesto protegido del viento y dem s agentes atmosf ricos 5 Ubique el generador como se describe en la secci n Ubicaci n del generador Evite que los gases de escape entren en un espacio cerrado a trav s de las ventanas puertas tomas de aire de ventilaci n u otras aberturas N ADVERTENCIA PELIGRO DE GAS VENENOSO Los gases del escape del motor contienen mon xido de carbono un gas venenoso que podr a matarlo 6 en minutos NO tiene olor color sabor Aun si no puede oler los vapores del escape podria estar expuesto al gas de mon xido de carbono e Utilice este producto NICAMENTE a la intemperie lejos de ventanas puertas y ventilaciones para reducir el riesgo de que el gas de mon xido de carbono se acumule y
70. imiento del 22 Almacenamiento iridia ceinen tenes deusa cee eet eee nee 25 Resoluci n de 26 Garant as 27 Garant a del sistema de control de 27 Garant a para el propietario de una 29 Especificaciones 30 Especificaciones del 30 Servicio COM N 30 troybilt com Seguridad de operario Etiquetas de seguridad Las etiquetas de seguridad de la m quina que se muestran a continuaci n y en la p gina siguiente est n colocadas en la m quina para llamar la atenci n sobre posibles riesgos de seguridad A DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home Only use OUTSIDE and or garage EVEN IF doors far away from windows and windows are open doors and vents 202997 Fire Hazard Fuel is flammable which could cause burns resulting in death or serious injury DO NOT fill fuel above baffle Always allow space for fuel expansion 319065 Fire hazard Hot exhaust and reflective exhaust gases could cause burns and fires resulting in death or serious injury Keep at least 5 ft 1 5
71. inados a demostraciones los equipos utilizados como fuente principal de energ a en lugar de un servicio p blico y los equipos sanitarios destinados al mantenimiento de las constantes vitales Esta garant a excluye los fallos debidos a hechos fortuitos y a otros acontecimientos de fuerza mayor que escapan al control del fabricante 198185S Rev D 10 5 2012 BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC MILWAUKEE WI EE UU 29 OTROY BILT Generador portatil Especificaciones del producto Vataje que 8 500 Vatios Vd thee beds odori ed a 6 250 Vatios Corriente valorada de Carga de C A 240 Voltios 26 0 Amperios 3 120 2 sii erage seta 52 0 Amperios Frecuencia Nominal 60 Hz at 3600 rpm ives Monof sica Desplazamiento 420 cc 25 63 cu in Buj a Separaci n 0 76 mm 0 030 in Capacidad de Gasolina 32 1 Litros 8 5 galones americanos Capacidad de Aceite 1 0 Litros 36 Onzas Servicio com n despide Depurador de aire 491588 5043 Botella de aceite de 100028 Botella de aceite sint tico 100074 Estabilizador de combustible 100120 o 100117 8308365 Potencia nominal El valor de potencia bruta nominal de cada
72. ing at governed speed DO NOT modify generator in any way troybilt com Storage The generator should be started at least once every seven days and allowed to run at least 30 minutes If this cannot be done and you must store the unit for more than 30 days use the following guidelines to prepare it for storage Generator Storage Clean the generator as outlined in Cleaning Check that cooling air slots and openings on generator are open and unobstructed Long Term Storage Instructions Fuel can become stale when stored over 30 days Stale fuel causes acid and gum deposits to form in the fuel system or on essential carburetor parts To keep fuel fresh use Briggs amp Stratton Advanced Formula Fuel Treatment amp Stabilizer available wherever Briggs amp Stratton genuine service parts are sold For engines equipped with a FRESH START fuel cap use Briggs amp Stratton FRESH START available in a drip concentrate cartridge There is no need to drain gasoline from the engine if a fuel stabilizer is added according to instructions Run the engine for 2 minutes to circulate the stabilizer throughout the fuel system before storage If gasoline in the engine has not been treated with a fuel stabilizer it must be drained into an approved container Run the engine until it stops from lack of fuel The use of a fuel stabilizer in the storage container is recommended to maintain freshness N WARNING Fuel and its
73. ing in serious injury When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback NEVER start or stop engine with electrical devices plugged in and turned on 17 Connecting Electrical Loads 1 Let engine stabilize and warm up for a few minutes after starting 2 Ensure main breaker is in On position 3 Plug in and turn on the desired 120 and or 240 Volt AC single phase 60 Hz electrical loads NOTICE When plugging into the 120 Volt receptacles plug items to be powered in sequence as shown below NOTICE DO NOT connect 240 Volt loads to 120 Volt duplex receptacles DO NOT connect 3 phase loads to generator DO NOT connect 50 Hz loads to generator DO NOT OVERLOAD THE GENERATOR See Don t Overload Generator NOTICE Exceeding generators wattage amperage capacity could damage generator and or electrical devices connected to it DO NOT exceed the generator s wattage amperage capacity See Don t Overload Generator in the Operation section Start generator and let engine stabilize before connecting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stopping generator 18 Stopping the Engine 1 Turn OFF and unplug all electrical loads from generator panel receptacles NEVER start or stop engine with electrical devices plugged in and turned O
74. iones de mantenimiento que se enumeran en el manual del propietario B amp S recomienda conservar todas las facturas relativas al mantenimiento del motor equipo pero B amp S no puede denegar la garant a bas ndose nicamente en la falta de facturas o en la imposibilidad por parte del propietario de asegurar la correcta realizaci n de todas las operaciones de mantenimiento Como propietario del motor equipo debe ser consciente de que B amp S puede denegar la cobertura de la garant a si el motor equipo o uno de sus componentes falla debido a un uso indebido o negligente un mantenimiento inadecuado o modificaciones no autorizadas Usted es responsable de presentar su motor equipo a un centro de distribuci n de B amp S distribuidor autorizado de servicio u otra entidad equivalente seg n corresponda en el momento en que surja un problema Las reparaciones cubiertas por la garant a se llevar n a cabo en un plazo razonable no superior a 30 d as en ning n caso En caso de preguntas sobre los derechos y responsabilidades relativos a la garant a p ngase en contacto con B amp S llamando al 1 800 444 7774 en USA o BRIGGSandSTRATTON COM Disposiciones de la garant a contra defectos del sistema de control de emisiones de Briggs amp Stratton A continuaci n se detallan las disposiciones concretas relativas a la Cobertura de la garant a contra defectos del sistema de control de emisiones Se afiaden a la garant a de motores de B
75. k arrester screen F Air Cleaner Protects engine by filtering dust and debris out of intake air G Choke Lever Used when starting a cold engine H Recoil Starter Used to start the engine manually J Engine Switch Set this switch to on I before starting engine Set switch to off 0 to shut off engine K Fuel Valve Used to turn fuel supply on and off to engine L Fuel Tank Capacity of 8 5 US gallons 32 1 1 M Main Breaker The receptacles are provided with a rocker switch main circuit breaker to protect the generator against electrical overload N 120 240 Volt AC 30 Amp Locking Receptacle May be used to supply electrical power for the operation of 120 and or 240 Volt AC 30 Amp single phase 60 Hz electrical lighting appliance tool and motor loads P 120 Volt AC 20 Amp Duplex Receptacles May be used to supply electrical power for the operation of 120 Volt AC 20 Amp single phase 60 Hz electrical lighting appliance tool and motor loads Items Not Shown Engine Identification Provides model type and code of engine Please have these readily available if calling for assistance Identification Label Provides model revision and serial number of generator Please have these readily available when calling for assistance 15 Cord Sets and Receptacles Use only high quality well insulated grounded extension cords with the generator s receptacles In
76. l equipo 6 eee RR 7 Informaci n importante de 7 Lir ae eS ees bee boon os wees 10 Desembalaje del generador 10 Instale el juego de ruedas 10 Comprobar el nivel de aceite del 11 Agregue combustible 2 0 lt lt cece eens 11 Tierra del odere RR Rer perm RR 11 Conexi n al sistema el ctrico de un edificio 12 Ubicaci n del generador port til 12 Controles y caracter sticas 15 Juegos de cordones y enchufes conectores 16 17 Enclenda el motor dda nd daa e s 17 Conexi n de cargas 18 Parada del motor ico pierda 18 Apagado debido a nivel bajo de 18 Operaci n durante un 18 No sobrecargar el 20 Mantenimiento 21 Plan de mantenimiento 21 Mantenimiento del generador 21 Mantenimiento de la v lvula de combustible 22 Manten
77. l rendimiento y prolongar la vida til del generador Acuda a un distribuidor autorizado para reparar la unidad La garant a del generador no cubre los elementos que hayan sido sujetos al abuso o negligencia del operador Para recibir el valor completo de la garant a el operador deber mantener el generador de la forma descrita en este manual Se deber n llevar a cabo algunos ajustes peri dicamente para mantener correctamente su generador Todos los ajustes de la secci n Servicio y Ajustes de este manual deber n ser hechos por lo menos una vez en cada estaci n Cumpla con los requisitos de la tabla Programa de Mantenimiento descrita anteriormente AVISO Una vez al afio deber limpiar o reemplazar la buj a y reemplazar el filtro de aire Una buj a nueva y un filtro de aire limpio garantizan una mezcla de combustible aire adecuada y ayuda a que su motor funcione mejor y tenga una vida til m s prolongada Control de emisiones Cualquier establecimiento o individuo especializado en la reparaci n de motores que no sean de automoci n puede encargarse del mantenimiento la sustituci n y la reparaci n de los dispositivos y sistemas de control de emisiones No obstante para realizar la revisi n gratuita de control de emisiones deber acudir a un distribuidor autorizado por el fabricante V ase Garant a de emisiones Mantenimiento del generador El mantenimiento del generador consiste en conservar la unidad limpia y
78. la posici n Half media y accione dos veces la manija de retroceso e Si el motor no arranca repita los pasos desde 5 hasta 7 7 Coloque la palanca de retroceso en la posici n de Run I l Si el motor vacila mueva la palanca de retroceso hasta la posici n media Half hasta que el motor marche suavemente y luego col quelo en la posici n de marcha Run 1 1 AVISO Si el motor se desborda coloque la palanca estranguladora en la posici n Run 1 1 e intente arrancarlo hasta conseguirlo AVISO Siel motor arranca despu s de tirar tres veces del arrancador pero no sigue funcionando o si la unidad se para en funcionamiento aseg rese de que la unidad est en una superficie plana y compruebe que el nivel de aceite del cig e al es correcto La unidad puede equiparse con un dispositivo de protecci n de bajo nivel de aceite En caso afirmativo el nivel del aceite debe ser adecuado para que el motor arranque N ADVERTENCIA Los gases y el calor de escape podr an inflamar los materiales combustibles y las estructuras o dafiar el dep sito de Cc CGC combustible y provocar incendios as como lesiones graves o incluso la muerte El contacto con la zona del silenciador podr a producir quemaduras y lesiones graves NO toque las superficies calientes y EVITE LOS gases del escape a alta temperatura Permita que el equipo se enfr e antes de tocarlo Deje un espacio m nimo de 1 5 m 5 pies
79. le Se recomienda utilizar un estabilizador de combustible en el contenedor de almacenamiento para mantener la gasolina en buen estado Cambio de aceite Con el motor todav a caliente drene el aceite de la caja del ciguenal Vuelva a llenarlo con el grado de aceite recomendado Vea Cambio de aceite del motor en Mantenimiento del motor Otras sugerencias para el almacenamiento 1 NO guarde combustible de una temporada a otra a menos que lo haya tratado como se indica en la secci n Almacenamiento Para Periodos Prolongados 2 Reemplace la caneca de gasolina si comienza a oxidarse El xido y o la suciedad en la gasolina le causar problemas 3 Cubra su unidad con una cubierta de protecci n adecuada que no retenga humedad A ADVERTENCIA Las fundas para almacenamiento A podr an provocar incendios y producir lesiones d N graves o incluso la muerte NO coloque una cubierta encima de un generador caliente Deje que la unidad se enfr e lo suficientemente antes de que le coloque la cubierta 4 Almacene la unidad en un rea limpia y seca Espa ol 2s Resolucion de problemas Reposicione el interruptor Revise y repare Conecte otro dispositivo que est buenas condiciones 4 Contacte el distribuidor de servicio autorizado Desconecte la carga el ctrica en corto Vea No Sobrerecarque Generador Problemo Causa Accion El interruptor de circuito est 1 abierto EI motor esta funcionando
80. led by a current licensed electrician The connection must isolate the generator power from the utility power and must comply with all applicable laws and electrical codes A WARNING Generator voltage could cause electrical A shock or burn resulting in death or serious injury Use listed transfer equipment suitable for the intended use to prevent backfeed by isolating generator from electric utility workers When using generator for backup power notify utility company Use a ground fault circuit interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator 11 Portable Generator Location Before starting the portable generator there are two equally important safety concerns regarding carbon monoxide CO poisoning and fire that must be addressed NOTICE Satisfying the RISK OF CARBON MONOXIDE POISONING location requirements may not satisfy the fire location requirements Satisfying the RISK OF FIRE location requirements may not satisfy the CARBON MONOXIDE POISONING location requirements Operation Location of P
81. ll with fresh fuel Connect wire to spark plug Replace spark plug Drain fuel tank and carburetor fill with fresh fuel Wait 5 minutes and re crank engine Contact authorized service facility Contact authorized service facility Contact authorized service facility Enalna Tacks jower 1 Load is too high 1 d 2 Dirty air filter 2 Engine hunts or falters Carburetor is running too rich or too lean Contact authorized service facility See Don t Overload Generator Replace air filter 26 troybilt com Warranties California U S EPA and Briggs amp Stratton Corporation Emissions Control Warranty Statement Your Warranty Rights And Obligations The California Air Resources Board U S EPA and Briggs amp Stratton B amp S are pleased to explain the emissions control system warranty on your Model Year 2013 2014 engine equipment In California new small off road engines and large spark ignited engines less than or equal to 1 0 liter must be designed built and equipped to meet the State s stringent anti smog standards B amp S must warrant the emissions control system on your engine equipment for the periods of time listed below provided there has been no abuse neglect or improper maintenance of your engine or equipment Your emissions control system may include parts such as the carburetor or fuel injection system ignition system and catalytic converter Also included may be
82. materiales GN combustibles y las estructuras o da ar el dep sito de combustible y provocar incendios as como lesiones graves o incluso la muerte El contacto con la zona del silenciador podr a producir quemaduras y lesiones graves NO toque las superficies calientes y EVITE los gases del escape a alta temperatura Permita que el equipo se enfr e antes de tocarlo Deje un espacio m nimo de 1 5 m 5 pies alrededor del generador incluida la parte superior Utilizar el motor en un terreno boscoso con maleza o cubierto de hierba constituye una infracci n al C digo de recursos p blicos de California a menos que el sistema de escape est equipado con una pantalla apagachispas de acuerdo a la definici n de la Secci n 4442 que se mantenga en buenas condiciones de funcionamiento En otros estados o jurisdicciones federales puede haber leyes similares en vigor P ngase en contacto con el fabricante el vendedor o el distribuidor del equipo original para obtener una pantalla apagachispas dise ada para el sistema de escape instalado en este motor Las piezas de recambio deben ser las mismas que las piezas originales y estar instaladas en la misma posici n Limpie e inspeccione el apagachispas de la siguiente manera 1 Para retirar la protecci n del silenciador A de silenciador B retire los cuatro tornillos que conectan la protecci n a la m nsula del silenciador 2 Retire los cuatro tornillos que sostienen la pantalla
83. mo responsable de la normativa vigente de conexi n a tierra E Silenciador apagachispas El silenciador disminuye el ruido del motor y est equipado con una pantalla apagachispas F Depurador de aire Filtra el aire de entrada a medida que penetra en el motor G Palanca del Cebador Usada cuando se est dando arranque a un motor fr o H Culatazo el principio Us para comenzar motor manualmente J Interruptor del Motor Deber estar en la posici n ON o En para darle arranque al motor Col quelo en la posici n OFF o O Apagado para detener un motor en funcionamiento K V lvula de combustible Permite abrir y cerrar la alimentaci n de combustible al motor L Tanque del combustible El tanque tiene una capacidad de 32 1 I 8 5 galones americanos de gasolina sin contenido de plomo M Disyuntor Basculante Un disyuntor basculante que protege el generador contra sobrecargas el ctricas N Tomacorriente con dispositivo de seguridad de 120 240 Voltios 30 Amp Puede ser utilizado para suministrar alimentaci n el ctrica para el funcionamiento de cargas del motor herramientas aparatos especiales e iluminaci n el ctrica de 120 y o 240 Voltios AC a 30 Amperios monof sica de 60 Hz P Tomacorriente dobles de 120 Voltios AC 20 Amp Pueden ser utilizados para suministrar alimentaci n el ctrica para el funcionamiento de cargas del motor herramientas aparatos espec
84. o de uso comercial a efectos de esta garant a Los equipos utilizados para suministrar energ a en sustituci n de un servicio p blico no pueden acogerse a esta garant a NO ES NECESARIO REGISTRAR LA GARANT A PARA OBTENER SERVICIO DE BRIGGS amp STRATTON PRODUCTS GUARDE SU RECIBO DE COMPRA SI NO APORTA LA PRUEBA DE LA FECHA DE COMPRA INICIAL SE UTILIZAR LA FECHA DE FABRICACI N DEL PRODUCTO PARA DETERMINAR EL PER ODO DE GARANTIA ACERCA DE LA EQUIPO GARANT A Esperamos que disfrute de nuestra garant a y le pedimos disculpas por las molestias causadas Cualquier distribuidor de servicio autorizado puede llevar a cabo reparaciones en garant a La mayor a de las reparaciones en garant a se gestionan normalmente pero algunas veces la solicitud de servicio en garant a puede no ser procedente Por ejemplo la garant a no ser v lida si el equipo presenta da os debidos al mal uso la falta de mantenimiento el transporte la manipulaci n el almacenamiento o la instalaci n inadecuados De manera similar la garant a quedar anulada si se ha borrado la fecha de fabricaci n o el n mero de serie del generador port til o si el equipo ha sido alterado o modificado Durante el per odo de garant a el distribuidor de servicio autorizado podr reparar o sustituir a su libre elecci n cualquier pieza que previa inspecci n sea defectuosa en condiciones normales de uso y servicio Esta garant a no cubre las reparaciones y equipos que se
85. oderado El motor est certificado para cumplir la normativa sobre emisiones durante 125 horas de funcionamiento real Intermedio El motor est certificado para cumplir la normativa sobre emisiones durante 250 horas de funcionamiento real Prolongado El motor est certificado para cumplir la normativa sobre emisiones durante 500 horas de funcionamiento real Por ejemplo un cortac sped con operario a pie se suele utilizar entre 20 y 25 horas al a o Por tanto el Per odo de Durabilidad de las Emisiones de un motor con clasificaci n intermedia equivaldr a a 10 12 a os Los motores Briggs amp Stratton cuentan con la certificaci n de cumplimiento de la fase 2 o fase 3 de las normativas sobre emisiones de la United States Environmental Protection Agency USEPA Agencia estadounidense de protecci n del medioambiente El per odo de cumplimiento de la normativa sobre emisiones que figura en la etiqueta de cumplimiento de emisiones indica el n mero de horas de funcionamiento durante las cuales el motor ha demostrado cumplir los requisitos federales sobre emisiones Para motores de menos de 225 cc Categor a C 125 horas Categoria B 250 horas Categoria A 500 horas Para motores de 225 cc o m s Categor a C 250 horas Categor a B 500 horas Categoria A 1000 horas troybilt com POLITICA PARA EL PROPIETARIO DE GENERADOR PORTATIL TROY BILT Fecha de entrada en vigor 1 de noviembre de 2012 sustituye a todas
86. oducto en el interior de un edificio cochera porche equipo m vil taller de aplicaciones navales o recinto NO incline el motor o el equipo de tal manera que la combustible se pueda derramar NO coloque el estrangulador en la posici n Choke Estrangulamiento para parar el motor CUANDO TRANSPORTE MOVER 0 REPARE EL EQUIPO Transporte mover o repare el equipo con el tanque de combustible vac o o con la v lvula para apagar el combustible apagada posici n OFF NO incline el motor o el equipo de tal manera que la combustible se pueda derramar Desconecte el cable de la buj a CUANDO ALMACENE 0 GUARDE EL EQUIPO CON COMBUSTIBLE EN EL TANQUE Almacene alejado de calderas estufas calentadores de agua secadoras de ropa u otros aparatos electrodom sticos que posean pilotos u otras fuentes de ignici n porque ellos pueden encender los vapores de la combustible Z ADVERTENCIA Este generador no cumple la norma 33CFR 183 del cuerpo de guardacostas de EE UU y no debe utilizarse en aplicaciones marinas El uso de un generador no homologado por cuerpo de guardacostas de EE UU puede provocar lesiones y dafios materiales troybilt com A ADVERTENCIA Los gases el calor de escape la podrian inflamar los materiales combustibles GS 2 Ny las estructuras o da ar el dep sito de combustible y provocar incendios as como lesiones graves o incluso la muerte El contacto con la zona del silenciador podr a producir qu
87. on Start generator and let engine stabilize before connecting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stopping generator NOTICE Improper treatment of generator could damage it and shorten its life Use generator only for intended uses If you have questions about intended use ask dealer or contact local service center Operate generator only on level surfaces DO NOT expose generator to excessive moisture dust dirt or corrosive vapors DO NOT insert any objects through cooling slots If connected devices overheat turn them off and disconnect them from generator Shut off generator if electrical output is lost equipment sparks smokes or emits flames unit vibrates excessively Assembly Read entire operator s manual before you attempt p y p to assemble or operate your new generator Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended fuel and oil level is verified If you have any problems with the assembly of your generator please call the generator helpline at 888 611 6708 If calling for assistance please have the model revision and serial number from the identification label available See generator Features and Controls for identification label location Unpack Generator 1 Set the carton on a rigid flat surface 2 R
88. on la varilla Si el nivel de aceite est entre las marcas ADD A adir y FULL Lleno de la varilla 1 NO intente volver a arrancar el motor 2 P ngase en contacto con un distribuidor autorizado de servicio Briggs amp Stratton 3 NO ponga a funcionar el motor sino hasta que se haya corregido el nivel de aceite Si el nivel de aceite est por debajo de la marca ADD A adir de la varilla 1 A ada aceite hasta llegar a la marca FULL Lleno 2 Ponga de nuevo en marcha el motor Si vuelve a pararse puede que siga existiendo un problema de baja presi n de aceite NO intente volver a arrancar el motor 3 P ngase en contacto con un distribuidor autorizado de servicio Briggs amp Stratton 4 NO ponga a funcionar el motor sino hasta que se haya corregido el nivel de aceite Operaci n durante un clima fr o En ciertas condiciones clim ticas temperaturas inferiores a 4 C 40 F combinadas con un alto nivel de humedad su generador puede experimentar formaci n de hielo en el carburador o el sistema de ventilaci n del c rter Para reducir este problema es necesario realizar lo siguiente 1 Aseg rese de que el generador tenga combustible nuevo y limpio 2 Abra la v lvula de combustible gire la v lvula a la posici n de abierto 3 Utilice aceite 5W 30 SAE 4 Verifique el nivel de aceite diariamente o despu s de cada ocho 8 horas de funcionamiento 5 Mantenga el generador que sigue el Plan de Mantenim
89. or de aire Ll nelo con combustible fresco Drene el tanque de gasolina ll nelo con combustible fresco Conecte el cable a la buj a Reemplace la buj a Drene el tanque de gasolina ll nelo con combustible fresco Abra por completo el cebador y haga girar el motor Contacte el distribuidor de servicio autorizado Contacte el distribuidor de servicio autorizado Contacte el distribuidor de servicio autorizado Al motor le hace falta 1 La carga es muy alta 1 potencia 2 Filtro de aire sucio 2 Vea No Sobrerecarque Generador Reemplace el filtro de aire Contacte el distribuidor de servicio autorizado 26 troybilt com Garantias Garantia de control de emisiones de California U S EPA y Briggs amp Stratton Corporation Derechos y obligaciones de la garant a California Air Resources Board U S EPA y Briggs amp Stratton B amp S le explican a continuaci n la garant a del sistema de control de emisiones de su motor equipo modelo 2013 2014 En California los nuevos motores pequefios para m quinas de servicio y los motores grandes con ignici n por buj as no superiores a 1 0 litro deben estar dise ados fabricados y equipados conforme a los exigentes est ndares de lucha contra la contaminaci n del Estado B amp S garantiza el sistema de control de emisiones de su motor equipo durante los per odos que se indican a continuaci n siempre que no haya habido uso indebido negligencia o man
90. or en ninguna forma AVISO Si se supera la capacidad de los generadores en vatios amperios se podr a da ar el generador y o los dispositivos el ctricos conectados a l NO exceda la capacidad en vatios amperios del generador Consulte No sobrecargar el generador en la secci n Operando Encienda su generador y deje que el motor se estabilice antes de conectar las cargas el ctricas Conecte las cargas el ctricas en la posici n de apagado OFF luego encienda ON para su operaci n Apague OFF las cargas el ctricas y descon ctelas del generador antes de parar el generador AVISO Un tratamiento inadecuado de la generador podr a da arla y acortar su vida til Use el generador solamente con la finalidad para el cual fue dise ado En caso de dudas sobre su uso dir jase al distribuidor Opere el generador solamente en superficies niveladas NO exponga al generador a una humedad excesiva polvo suciedad o vapores corrosivos NO inserte cualquier objeto a trav s de las ranuras de enfriamiento Silos aparatos conectados se sobre calientan ap guelos y descon ctelos del generador Apague el generador si Se pierde la salida el ctrica El equipo produce chispas humo o emite llamas La unidad vibra de una manera excesiva Espa ol Montaje Su generador requiere de ciertos procedimientos de montaje y solo estar listo para ser utilizado despu s de haberle suministrado servicio
91. ortable Generator to REDUCE THE RISK OF CARBON MONOXIDE POISONING All fossil fuel burning equipment such as a portable generator contains carbon monoxide CO gas in the engine exhaust a poisonous gas that could kill you in minutes You CANNOT smell it see it or taste it Even if you do not smell exhaust fumes you could still be exposed to carbon monoxide gas The following must be completed prior to starting the portable generator engine A DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and vents By law it is required in many states to have a Carbon Monoxide CO alarm A in operating condition in your home Install maintain battery operated carbon monoxide alarms or plug in carbon monoxide alarms with battery back up according to the manufacturer s instructions A CO alarm is an electronic device that detects hazardous levels of CO When there is a buildup of CO the alarm will alert the occupants by flashing visual indicator light and alarm Smoke alarms cannot detect CO gas SMOKE AND CARBON MONOXIDE ALARM Operate this product ONLY outside far away from windows doors and vents to reduce the risk of carbon monoxide gas from accumulating and potentially being drawn towards occupie
92. os Usted no tendr que ir muy lejos para encontrar el servicio t cnico de Briggs amp Stratton para su generador Consulte las P ginas Amarillas Hay m s de 30 000 proveedores de Briggs amp Stratton autorizados en todo el mundo proporcionando un servicio de calidad Tambi n puede ponerse en contacto con Atenci n al Cliente de Troy Bilt llamando al 888 611 6708 o por Internet en www troybilt com Generador Revision EN Motor N mero de modelo Fecha de compra I I I Copyright 2013 Briggs amp Stratton Power Products Group LLC Milwaukee WI USA Reservados todos los derechos TROY BILT es una marca registrada de MTD Usa abajo licencia 2 troybilt com Lista de control para una operaci n segura Para la operaci n segura del generador port til es necesario que se completen las siguientes tareas Alarma de mon xido de carbono CO O Las alarmas de mon xido de carbono CO deben estar en buenas condiciones de funcionamiento Alarma de humo L1 Las alarmas de humo deben estar en buenas condiciones de funcionamiento Ubicaci n del generador O El generador se debe colocar en un rea en la que no se acumule el mon xido de carbono CO Consulte Colocaci n del generador para reducir el riesgo de envenenamiento por mon xido de carbono O El generador se debe colocar en un rea a prueba de incendios Consulte Colocaci n del generador para reducir el riesgo de incendio O El generador se debe coloc
93. os gases de escape del motor de su generador port til y esto debe tomarse en cuenta al momento de decidir la ubicaci n para que el generador port til funcione de manera segura SIEMPRE coloque este producto en direcci n del viento y dirija el escape del motor en sentido contrario a los espacios habitados Si comienza a sentirse mal mareado o d bil cuando use este producto ap guelo y busque aire puro DE INMEDIATO Acuda a un m dico Es posible que se haya envenenado con mon xido de carbono troybilt com EJEMPLO DE UBICACION PARA REDUCIR EL RIESGO DE ENVENENAMIENTO POR MONOXIDO DE CARBONO selo S LO a la intemperie y en direcci n del viento lejos de ventanas puertas y ventilaciones La direcci n del escape debe seren q sentido contrario a los espacios habitados NO PONGA EL GENERADOR EN FUNCIONAMIENTO EN NINGUNA DE LAS SIGUIENTES UBICACIONES Entra Porche Recibidor Alarma de mon xido de carbono S tano o Entreplantas Espa ol 13 Ubicaci n de operaci n del generador port til para REDUCIR EL RIESGO DE INCENDIOS A ADVERTENCIA Los gases y el calor de escape podr an inflamar los materiales combustibles y las estructuras o da ar el dep sito de combustible y provocar incendios as como lesiones graves o incluso la muerte El generador port til debe estar por lo menos a 5 pies 1 5 m de cualquier estructura saliente rbol ventana
94. ound to be defective under normal use and service This warranty will not cover the following repairs and equipment Normal Wear Outdoor Power Equipment like all mechanical devices needs periodic parts and service to perform well This warranty does not cover repair when normal use has exhausted the life of a part or the equipment Installation and Maintenance This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized installation or alteration and modification misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in our judgment to adversely affect its performance and reliability This warranty also does not cover normal maintenance such as air filters adjustments fuel system cleaning and obstruction due to chemical dirt carbon lime and so forth Other Exclusions This warranty excludes wear items such as o rings filters etc or malfunctions resulting from accidents abuse modifications alterations or improper servicing or freezing or chemical deterioration Accessory parts such as starting batteries generator adapter cord sets and storage covers are excluded from the product warranty This warranty excludes used reconditioned and demonstration equipment equipment used for prime power in place of utility power equipment used in life support applications and failures due to acts of God and other force majeure events beyond the manufac
95. oved fuels could damage generator and voids warranty e DO NOT use unapproved gasoline such as E15 and E85 DO NOT mix oil in gasoline or modify engine to run on alternate fuels To protect the fuel system from gum formation mix in a fuel stabilizer when adding fuel See Storage All fuel is not the same If you experience starting or performance problems after using fuel switch to a different fuel provider or change brands This engine is certified to operate on gasoline The emission control system for this engine is EM Engine Modifications N WARNING Fuel and its vapors are extremely flammable and explosive which could cause burns fire la Ao explosion resulting in death or serious injury WHEN ADDING FUEL Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fill fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion If fuel spills wait until it evaporates before starting engine Keep fuel away from sparks open flames pilot lights heat and other ignition sources Check fuel lines tank cap and fittings frequently for cracks or leaks Replace if necessary DO NOT light a cigarette or smoke 1 Clean area around fuel fill cap remove cap 2 Slowly add unleaded gasoline A to fuel tank B Be careful not to fill above the baffle C This allows adequate space for fuel expansion as shown 3 Install fuel cap
96. per odo de garant a restante Los fallos de todo componente cubierto por la garant a que se deba sustituir como parte del plan de mantenimiento obligatorio detallado en el manual del propietario entregado quedar n cubiertos por la garant a hasta el momento en que se indique que es necesario hacer la primera sustituci n Si el componente falla antes de la fecha de la primera sustituci n ser reparado o sustituido por B amp S sin cargo alguno para el propietario Los componentes que se reparen o sustituyan en virtud de la garant a estar n cubiertos por la garant a durante el per odo de garant a hasta llegar a la fecha de la primera sustituci n No se podr n utilizar componentes complementarios o modificados no exentos por el Air Resources Board El uso de componentes complementarios o modificados no exentos por parte del propietario dar lugar a la anulaci n de la garant a El fabricante no ser responsable de los fallos de componentes cubiertos por la garant a que se deban al uso de un componente complementario o modificado no exento 3 Cobertura de da os derivados La cobertura se ampliar a los fallos de cualquier componente del motor derivados del fallo de cualquier componente relacionado con el sistema de emisiones cubierto por la garant a 4 Solicitudes y exclusiones de cobertura Las solicitudes de garant a se cumplimentar n con arreglo a las disposiciones de la pol tica de garant a de motores B amp
97. pliance Starting Watts Exwas 5 00 00 00 00 J 1800 Windowran 1 300 600 Furnace Fan Blower 1 2 HP 1300 Microwave Oven 1000 Watt 1000 Pe Coffee Maker 1500 Electric Stove Single Element ot Plate Family Room DVD CD Player VCR Stereo Receiver Color Television 27 500 Personal Computer w 17 monitor soo Security System AM FM Clock Radio 300 Electric Water Heater 40 Gallon 4000 DIY Job Site if Quartz Halogen Work Light 1000 Airless Sprayer 1 8HP 60 1200 Reciprocating Saw 960 Wattages listed are approximate only Check tool or appliance for actual wattage Li Heati troybilt com Maintenance Maintenance Schedule Follow the hourly or calendar intervals whichever occurs first More frequent service is required when operating in adverse conditions noted below Hess 1 Service more often under dirty or dusty conditions General Recommendations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subjected to operator abuse or negligence To receive full value from the warranty the operator must maintain the generator as instructed in this manual Some adjustments will need to be made periodically
98. que instala la rueda con el cubo elevado hacia el interior 5 Deslice el arandela plana D por encima de eje 6 Coloque un anillo en E E en la ranura del eje 7 Para ello apriete con unas pinzas desde la parte superior del anillo en E hacia la parte inferior del eje A ADVERTENCIA Las anillas en e podr a provocar lesiones oculares Las anillas en e podr an salir disparadas durante el montaje o el desmontaje lo que puede tener como resultado lesiones moderadas Utilice siempre protecci n ocular para montar o desmontar anillas en 8 Repita los pasos del 3 al 7 para asegurar la segunda rueda 10 Haga coincidir los orificios de la pata de apoyo F con los del armaz n del generador 11 Monte la pata de apoyo usando dos tornillos de cabeza G y dos tuercas hexagonales H Apriete con llaves de 13 mm 12 Repita los pasos del 9 y 10 para asegurar la segunda pata de apoyo 13 Vuelva a colocar el generador en la posici n normal de funcionamiento apoyado en las ruedas y patas de apoyo Fije las cubiertas a los disyuntores Se incluye un par de cubiertas de goma para que se coloquen sobre los disyuntores de rearme por presi n complementarios con fines de protecci n Coloque las cubiertas de goma J sobre cada uno de los disyuntores de rearme por presi n K y enr squelas Apriete a mano solamente troybilt com Comprobar el nivel de aceite del motor El generador sale de
99. rage of failures of emissions parts caused by the use of add on or modified parts 28 Look For Relevant Emissions Durability Period and Air Index Information On Your Small Off Road Engine Emissions Label Engines that are certified to meet the California Air Resources Board CARB small off road Emissions Standard must display information regarding the Emissions Durability Period and the Air Index Briggs amp Stratton makes this information available to the consumer on our emissions labels The engine emissions label will indicate certification information The Emissions Durability Period describes the number of hours of actual running time for which the engine is certified to be emissions compliant assuming proper maintenance in accordance with the Operating amp Maintenance Instructions The following categories are used Moderate Engine is certified to be emissions compliant for 125 hours of actual engine running time Intermediate Engine is certified to be emissions compliant for 250 hours of actual engine running time Extended Engine is certified to be emissions compliant for 500 hours of actual engine running time For example a typical walk behind lawn mower is used 20 to 25 hours per year Therefore the Emissions Durability Period of an engine with an intermediate rating would equate to 10 to 12 years Briggs amp Stratton engines are certified to meet the United States Environmental Protection Agency USEPA P
100. rain plug is located at base of engine opposite carburetor 4 Remove oil drain plug and drain oil completely into a suitable container 5 Reinstall oil drain plug and tighten securely Remove oil cap dipstick 6 Slowly pour recommended oil about 36 oz 1 0 1 into oil fill opening Pause to permit oil to settle Fill to Full mark on dipstick 7 Wipe dipstick clean each time oil level is checked DO NOT overfill 8 Reinstall oil cap dipstick Tighten cap securely 9 Wipe up any spilled oil Service Air Cleaner Your engine will not run properly and may be damaged if you run it with a dirty air cleaner Clean or replace more often if operating under dusty or dirty conditions To service the air cleaner follow these steps 1 Loosen screws B and remove air cleaner cover C 2 Carefully remove cartridge D from base E 3 Install clean or new air cleaner assembly inside cover Dispose of old filter properly 4 Assemble air cleaner cover onto base and tighten screws Service Spark Plug Changing the spark plug will help your engine to start easier and run better 1 Clean area around spark plug 2 Remove and inspect spark plug 3 Check electrode gap with wire feeler gauge and reset spark plug gap to recommended gap if necessary see Specifications Q ON 4 Replace spark plug if electrodes are pitted burned or porcelain is cracked Use the r
101. rator from electric utility workers When using generator for backup power notify utility company Use a ground fault circuit interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator A WARNING Exhaust heat gases could ignite combustibles structures or damage fuel tank la WAS La LAN casing a fire resulting in death or serious injury Contact with muffler area could cause burns resulting in serious injury DO NOT touch hot parts and AVOID hot exhaust gases Allow equipment to cool before touching Keep at least 5 feet 1 5 m of clearance on all sides of generator including overhead It is a violation of California Public Resource Code Section 4442 to use or operate the engine on any forest covered brush covered or grass covered land unless the exhaust system is equipped with a spark arrester as defined in Section 4442 maintained in effective working order Other states or federal jurisdictions may have similar laws Contact the original equipment manufacturer retailer or dealer to obtain a spark arrester designed
102. riales ni de mano de obra que provoquen el fallo de un componente cubierto y que es id ntico en todos los aspectos materiales al motor descrito en la aplicaci n de certificaci n del fabricante El per odo de garant a comienza en la fecha de adquisici n original del motor Dos afios o el per odo que se indica en la garant a del motor 0 producto correspondiente lo que sea m s prolongado Espa ol La garantia de los componentes relacionados con las emisiones es la siguiente Los fallos de todo componente cubierto por la garant a que no se deba sustituir como parte del plan de mantenimiento obligatorio detallado en el manual del propietario entregado quedar n cubiertos por la garant a durante el per odo de la garant a especificado anteriormente Si alguno de estos componentes falla durante el per odo de cobertura de la garant a deber ser reparado o sustituido por B amp S sin cargo alguno para el propietario Los componentes que se reparen 0 sustituyan en virtud de la garant a estar n cubiertos por la garant a durante el per odo de garant a restante os fallos de todo componente cubierto por la garant a que s lo se deba inspeccionar peri dicamente seg n el manual del propietario entregado quedar n cubiertos por la garant a durante el per odo de la garant a especificado anteriormente Los componentes que se reparen o sustituyan en virtud de la garant a estar n cubiertos por la garant a durante el
103. roblemas de congelaci n AVISO Sise ha montado un juego de ruedas en el generador ampl e la estructura de protecci n 3 Siga los pasos del 3 al 8 descritos en la secci n Creaci n de una estructura de protecci n provisional para climas fr os Espa ol 19 No sobrecargar el generador Capacidad Debe asegurarse de que su generador puede proveer los suficientes vatios de potencia continua vatiaje nominal y vatios de salida para los elementos que desee alimentar al mismo tiempo Siga estos sencillos pasos 1 Seleccione los elementos que quiere alimentar al mismo tiempo 2 Sume la potencia nominal de esos elementos Esa es la cantidad de energia que su generador debe producir para mantener sus elementos en funcionamiento Vea Guia de Referencia de Potencia 3 Calcule cu ntos vatios de salida necesitar La potencia de salida se refiere al corto arranque de energ a que se necesita para arrancar herramientas o dispositivos a motor como una radial o un refrigerador Como no todos los motores arrancan al mismo tiempo el total de vatios de salida puede calcularse af adiendo s lo el elemento con la potencia de salida m s alta al total de vatios de potencia continua que obtuvimos en el paso 2 Ejemplo Herramienta o Aparato El ctrico s Vatios Calificados cuando Vatios Adicionales de alto est funcionando Carga al encender Aire Acondicionado de Ventana Refrigerador Congelador industrial Televisi n
104. seca Opere y almacene la unidad en un ambiente limpio y seco donde no ser expuesta al polvo suciedad humedad o vapores corrosivos Las ranuras del aire de enfriamiento del generador no deben estar tapadas con nieve hojas o cualquier otro material extrafios Revise frecuentemente la limpieza del generador y limpielo cuando est con polvo sucio con aceite humedad o cuando otras substancias extrafias sean visibles en su superficie exterior AVISO No utilice agua u otros l quidos para limpiar el generador Los l quidos pueden penetrar en el circuito de combustible del motor y provocar p rdidas de rendimiento 0 fallos Asimismo si penetran l quidos en el generador a trav s de las ranuras del aire de refrigeraci n parte del l quido puede permanecer en los huecos y rendijas del aislamiento del devanado del rotor y del estator El l quido y la acumulaci n de suciedad en los devanados internos del generador pueden reducir la resistencia del aislamiento Limpieza Limpie a diario o antes de cada uso los residuos acumulados en el generador Mantenga limpias las conexiones los muelles y los mandos Limpie todo resto de combustible de la zona que rodea al silenciador y de detr s del mismo Inspeccione las ranuras para aire de enfriamiento y la apertura del generador Estas aperturas deber n mantenerse limpias y despejadas Mantenga limpios los componentes del generador para reducir el riesgo de sobrecalentamiento e ignici n
105. smo competente En algunas zonas es obligatorio registrar los generadores en las compa as el ctricas locales Si el generador se utiliza en una obra puede ser necesario cumplir normas y requisitos adicionales Espa ol n Conexion al sistema el ctrico de un edificio Un electricista con licencia vigente debe instalar el conectador indicado para realizar las conexiones de la alimentaci n de reserva para el sistema el ctrico del edificio La conexi n debe aislar la alimentaci n del generador de la alimentaci n de la red p blica y debe cumplir con todas las leyes y normas el ctricas vigentes ADVERTENCIA El voltaje del generador podria AR provocar descargas el ctricas o quemaduras que pueden producir lesiones graves o la muerte Utilice los equipos de transferencia indicados ideales para el uso deseado a fin de evitar la retroalimentaci n ya que se a sla el generador de las personas que trabajan con el suministro el ctrico Si utiliza el generador como sistema de reserva notif quelo a la compa a el ctrica Use un interruptor para la falla del circuito de tierra GFCI en cualquier rea bastante h meda o que sea altamente conductiva tales como terrazas de metal o trabajo hecho con acero NO toque los alambres pelados o recept culos NO use un generador con cables el ctricos que est n malgastados rotos pelados o dafiados de cualquier forma NO opere el generador bajo la lluvia NO maneje
106. spect extension cords before each use Check the ratings of all extension cords before you use them Check the operator s manuals of devices for the manufacturer s recommendations A double pole rocker switch main circuit breaker is provided to protect the locking receptacle If this circuit breaker is tripped all receptacles are disconnected N WARNING Damaged or overloaded electrical cords JN could overheat arc and burn resulting in death or y serious injury ONLY use cords rated for your loads Follow all safeties on electrical cords nspect cord sets before each use 120 240 Volt AC 30 Amp Locking Receptacle Use a NEMA L14 30 plug with this receptacle Connect a 4 wire cord set rated for 250 Volt AC loads at 30 Amps or greater You can use the same 4 wire cord if you plan to run a 120 Volt load 240V 120V Wire Cord Set W Neutral md Y Hot X Hot Ground Green This receptacle powers 120 240 Volt AC 60 Hz single phase loads requiring up to 6 250 watts of power 6 25 kW at 26 0 Amps for 240 Volts or two independent 120 Volt loads at 26 0 Amps each The outlet is protected by a two pole rocker switch circuit breaker NEMA L14 30 NOTICE Receptacles may be marked with rating value greater than generator output capacity NEVER attempt to power a device requiring more amperage than generator or receptacle can supply DO NOT overload the generator See Don t Overload G
107. sulting in death or serious injury Transfer switch must be used when connecting to a building s electrical system Do not run generator in rain or wet weather Burn Hazard 2 Muffler area could af cause burns Do not touch hot parts Avoid hot exhaust gases 319064 troybilt com Equipment Description co Read this manual carefully and become familiar E with your generator Know its applications its limitations and any hazards involved The generator is an engine driven revolving field alternating current AC generator equipped with a voltage regulator The voltage regulator is designed to automatically maintain a constant output voltage level It was designed to supply electrical power for operating compatible electrical lighting appliances tools and motor loads The generator s revolving field is driven at about 3600 rpm by a single cylinder engine NOTICE Exceeding generators wattage amperage capacity could damage generator and or electrical devices connected to it e DO NOT exceed the generator s wattage amperage capacity See Don t Overload Generator in the Operation section Every effort has been made to ensure that the information in this manual is both accurate and current However the manufacturer reserves the right to change alter or otherwise improve the generator and this documentation at any time without prior notice The Emission Control Sys
108. t the spark arrester as follows 1 To remove muffler heat shield A from muffler B remove four screws that connect guard to muffler bracket 2 Remove four screws that attach spark arrester screen C 3 Inspect screen and obtain a replacement if torn perforated or otherwise damaged DO NOT use a defective screen If screen is not damaged clean it with commercial solvent 4 Reattach screen and muffler guard 24 Clean Cooling System Over time debris may accumulate in cylinder cooling fins and cannot be observed without partial engine disassembly For this reason we recommend you have a Briggs amp Stratton authorized dealer clean the cooling system D per recommended intervals see Maintenance Schedule in the Maintenance section Equally important is to keep top of engine free from debris Also see Cleaning Carburetor Adjustment The carburetor on this engine is low emission It is equipped with a non adjustable idle mixture valve Top speed has been set at the factory If adjustment is required see a Briggs amp Stratton authorized dealer A CAUTION Excessively high operating speeds could result in minor injury Excessively low speeds impose a heavy load DO NOT tamper with governor spring links or other parts to increase engine speed Generator supplies correct rated frequency and voltage when runn
109. tacto con la zona del silenciador podr a producir quemaduras y lesiones graves NO toque las superficies calientES Y EVITE LOS GASes del escape a alta temperatura Permita que el equipo se enfr e antes de tocarlo Deje un espacio m nimo de 1 5 m 5 pies alrededor del generador incluida la parte superior Retire la protecci n cuando las temperaturas sean superiores a 4 C 40 F 7 Retire la protecci n cuando las temperaturas sean superiores a 4 C 40 F 8 Pare el motor y d jelo enfriar durante dos 2 minutos antes de repostar combustible La espera para alg n combustible rociado para evaporar Construcci n de una estructura de protecci n para climas fr os 1 Construya una estructura de protecci n capaz de contener tres laterales y la parte superior del generador Utilice para ello materiales no combustibles con una resistencia al fuego de al menos una hora Aseg rese de que el lateral del silenciador del generador quede al descubierto AVISO P ngase en contacto con su proveedor de materiales de construcci n para conseguir materiales no combustibles con una resistencia al fuego de al menos una hora AVISO Aseg rese de que la estructura de protecci n se pueda mover f cilmente para adaptarla a la direcci n del viento 2 NO encierre el generador m s de lo que se muestra en la figura La estructura de protecci n debe mantener una cantidad suficiente del calor disipado por el generador para evitar p
110. tarlo en minutos NO tiene olor color ni sabor Aun si no puede oler los vapores del escape podr a estar expuesto al gas de mon xido de carbono e Utilice este producto NICAMENTE a la intemperie lejos de ventanas puertas y ventilaciones para reducir el riesgo de que el gas de mon xido de carbono se acumule y entre en los espacios habitados Instale alarmas para detectar mon xido de carbono operadas con bater as o enchufables con bater as de repuesto de acuerdo con las instrucciones del fabricante Las alarmas de humo no pueden detectar el gas de mon xido de carbono NO utilice este producto dentro de casas garajes s tanos entresuelos cobertizos o en otros espacios parcialmente cerrados a n si utiliza ventiladores o deja las puertas y ventanas abiertas para favorecer la ventilaci n El mon xido de carbono puede acumularse r pidamente en estos espacios y perdurar ah durante horas aun despu s de que este producto se haya apagado SIEMPRE coloque este producto en direcci n del viento y dirija el escape del motor en sentido contrario a los espacios habitados Si comienza a sentirse mal mareado o d bil cuando use este producto ap guelo y busque aire puro DE INMEDIATO Acuda a un m dico Es posible que se haya envenenado con mon xido de carbono N ADVERTENCIA El arrancador y otras piezas rotativas N Podr an enredarse en las manos el pelo la ropa u A otros accesorios y provocar lesiones graves e NUNCA
111. tem for this generator is warranted for standards set by the Environmental Protection Agency and the California Air Resources Board Important Safety Information The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all inclusive If you use a procedure work method or operating technique that the manufacturer does not specifically recommend you must satisfy yourself that it is safe for you and others You must also make sure that the procedure work method or operating technique that you choose does not render the generator unsafe Safety Symbols and Meanings Toxic Fumes Kickback Electrical Shock Fire Explosion Operators Manual Moving Parts Flying Objects Hot Surface The safety alert symbol indicates a potential personal injury hazard A signal word DANGER WARNING or CAUTION is used with the alert symbol to designate a degree or level of hazard seriousness A safety symbol may be used to represent the type of hazard The signal word NOTICE is used to address practices not related to personal injury A DANGER indicates a hazard which if not avoided will result in death or serious injury N WARNING indicates a hazard which if not avoided could result in death or serious injury A CAUTION indicates a hazard which if not avoided could result in minor or moderate injury NOTICE ad
112. temperature position time sensitive valves and switches Connectors and assemblies 2 Length of Coverage For a period of two years from date of original purchase B amp S warrants to the original purchaser and each subsequent purchaser that the engine is designed built and equipped so as to conform with all applicable regulations adopted by the Air Resources Board that it is free from defects in material and workmanship that could cause the failure of a warranted part and that it is identical in all material respects to the engine described in the manufacturer s application for certification The warranty period begins on the date the engine is originally purchased Two years or for the time period listed in the respective engine or product warranty statement whichever is greater 21 The warranty on emissions related parts is as follows Any warranted part that is not scheduled for replacement as required maintenance in the owner s manual supplied is warranted for the warranty period stated above If any such part fails during the period of warranty coverage the part will be repaired or replaced by B amp S at no charge to the owner Any such part repaired or replaced under the warranty will be warranted for the remaining warranty period Any warranted part that is scheduled only for regular inspection in the owner s manual supplied is warranted for the warranty period stated above Any such part repaired or replaced un
113. tenimiento indebido del motor o equipo para m quinas de servicio Su sistema de control de emisiones puede incluir componentes como el carburador o el sistema de inyecci n de combustible el sistema de arranque y el convertidor catal tico Tambi n puede incluir mangueras correas conectores detectores y otros conjuntos relacionados con las emisiones El sistema de control de emisiones por evaporaci n puede incluir los siguientes componentes carburadores dep sitos de combustible conductos de combustible tapones de combustible v lvulas cartuchos filtros mangueras de vapor abrazaderas conectores y otros componentes asociados Si se cumplen las condiciones de la garant a B amp S reparar el motor equipo sin coste alguno incluido el diagn stico los componentes y la mano de obra Cobertura de la garant a del fabricante Los motores peque os para m quinas de servicio y los motores grandes con ignici n por buj as de 1 0 litros o menos y muchos componentes del equipo relacionados con las emisiones tienen una garant a de dos a os Si alg n componente del motor equipo relacionado con las emisiones estuviera defectuoso B amp S lo reparar o sustituir Dos afios o el per odo que se indica en la garant a del motor o producto correspondiente lo que sea m s prolongado Responsabilidades de la garant a del propietario Como propietario del motor equipo usted es responsable de llevar a cabo todas las operac
114. tep 9 and 10 to secure second support leg 13 Return generator to normal operating position resting on wheels and support legs Attach Boots to Circuit Breakers A pair of rubber boots are being supplied to place over the supplemental push to reset circuit breakers for protection Place rubber boot J over each push to reset circuit breaker K and screw on Tighten by hand only c 4 MN Verify Engine Oil Level The generator engine is shipped from the factory filled with oil API SJ or higher 10W 30 This allows for generator operation in the widest range of temperature and climate conditions Before starting the engine check oil level and ensure that engine is serviced as described in Maintenance NOTICE Any attempt to crank or start the engine before it has been properly filled with the recommended oil could result in equipment failure Refer to Maintenance for oil fill information Damage to equipment resulting from failure to follow this instruction will void warranty NOTICE See Oil in the Maintenance section to review oil recomendations Verify provided oil in engine is the correct viscosity for current ambient temperature I troybilt com Add Fuel Fuel must meet these requirements Clean fresh unleaded gasoline A minimum of 87 octane 87 AKI 91 RON For high altitude use see High Altitude Gasoline with up to 10 ethanol gasohol is acceptable NOTICE Use of unappr
115. tick with clean cloth Replace dipstick Remove and and check oil level NOTICE DO NOT screw in dipstick when checking oil level 3 Verify oil is at Full mark D on dipstick Replace and tighten oil cap dipstick Adding Engine Oil 1 Make sure generator is on a level surface 2 Check oil level as described in Checking Oil Level 3 If needed slowly pour oil into oil fill opening to the Full mark on dipstick DO NOT overfill NOTICE Overfilling with oil could cause the engine to not start or hard starting DO NOT overfill f over the FULL mark on dipstick drain oil to reduce oil level to FULL mark on dipstick 4 Replace and tighten oil cap dipstick troybilt com Changing Engine Oil If you are using your generator under extremely dirty or dusty conditions or in extremely hot weather change the oil more often A CAUTION Avoid prolonged or repeated skin contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Change the oil while the engine is still warm from running as follows 1 Make sure unit is on a level surface 2 Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug 3 Clean area around oil drain plug A The oil d
116. to properly maintain your generator All service and adjustments should be made at least once each season Follow the requirements in the Maintenance Schedule chart above NOTICE Once a year you should clean or replace the spark plug and replace the air filter A new spark plug and clean air filter assure proper fuel air mixture and help your engine run better and last longer Emissions Control Maintenance replacement or repair of the emissions control devices and systems may be performed by any non road engine repair establishment or individual However to obtain no charge emissions control service the work must be performed by a factory authorized dealer See the Emissions Warranty Generator Maintenance Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture or any corrosive vapors Cooling air slots in the generator must not become clogged with snow leaves or any other foreign material NOTICE DO NOT use water or other liquids to clean generator Liquids can enter engine fuel system causing poor performance and or failure to occur In addition if liquid enters generator through cooling air slots some of the liquid will be retained in voids and cracks of the rotor and stator winding insulation Liquid and dirt buildup on the generator internal windings will eventually decrease the insulation r
117. to open position 3 Use SAE 5W 30 oil 4 Check oil level daily or after every eight 8 hours of operation 5 Maintain generator following Maintenance Schedule in Maintenance section 6 Shelter unit from elements troybilt com Creating a Temporary Cold Weather Shelter 1 For temporary shelter the original shipping carton can be used 2 Cut off top carton flaps and one long side of carton to expose muffler side of unit If required tape up other sides of carton to fit over generator as shown NOTICE f required remove wheel kit to fit carton over generator as shown 3 Cut appropriate slots to access receptacles of unit 4 Face exposed end away from wind and elements 5 Locate generator as described in the section Generator Location Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other openings A WARNING POISONOUS GAS HAZARD Engine exhaust contains carbon monoxide a poisonous that could kill you in minutes You CANNOT smell it see it or taste it Even if you do not smell exhaust fumes you could still be exposed to carbon monoxide gas Operate this product ONLY outside far away from windows doors and vents to reduce the risk of carbon monoxide gas from accumulating and potentially being drawn towards occupied spaces Install battery operated carbon monoxide alarms or plug in carbon monoxide alarms with battery back up according to the manufacturer s
118. turers control 198185E Rev D 10 5 2012 BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC MILWAUKEE WI USA 29 OTROY BILT Portable Generator Product Specifications Starting Wattage 8 500 Watts 6 250 Watts AG VoltaiB o bd bit REO 120 240 Volts at 240 Volts oos oce 26 0 Amps at 120 VOS ed 52 0 Amps Frequency caviar be RR eed 60 Hz at 3600 rpm ULL E Single Phase 25 63 420 Spark Plug 0 030 0 76 Fuel Capacity 8 5 US Gallons 32 1 Liters Dil 36 Ounces 1 0 Liters Common Service Parts Air Cleaner eee 491588 or 5043 Engine Oil Bottle 100028 Synthetic Oil Bottle 100074 Fuel StabiliZer 100120 or 100117 Spark 83083GS Power Ratings The gross power rating for individual gasoline engine models is labeled in accordance with SAE Society of Automotive Engineers code J1940 Small Engine Power amp Torque Rating Procedure and is rated in accordance with SAE J1995 Torque values are derived at 2600 RPM for those engines with rpm called out on the label and 3060 RPM for all others horsepower values are derived at 3600 RPM The gross power curves can be viewed at www
119. ue dise ado con la finalidad de proveer energ a el ctrica para l mparas el ctricas aparatos herramientas y cargas de motor compatibles El campo giratorio del generador se mueve a unas 3 600 rpm con un motor de un uno cilindro El generador viene equipado con un regulador autom tico de tensi n que regula la tensi n de salida de manera autom tica Este toma distintos niveles de tensi n y los convierte a un nivel de tensi n de salida constante AVISO Si se supera la capacidad de los generadores en vatios amperios se podr a da ar el generador y o los dispositivos el ctricos conectados a l NO exceda la capacidad en vatios amperios del generador Consulte No sobrecargar el generador en la secci n Operando Se ha realizado el m ximo esfuerzo para reunir en este documento la informaci n m s precisa y actualizada No obstante nos reservamos el derecho de modificar alterar o mejorar de cualquier otra forma el generador en cualquier momento y sin previo aviso El Sistema de control de emisiones para este generador est garantizado para juegos est ndares por la Agencia de protecci n ambiental y el Consejo de recursos de aire de California Informaci n importante de seguridad El fabricante no puede anticipar todas las posibles circunstancias que podr an conllevar peligro Por lo tanto las advertencias de este manual as como las etiquetas y placas de la unidad no incluyen todo Si usa un procedimiento m todo
120. utilice la generador sin sus carcasas o tapas de protecci n e NO utilice ropa suelta joyas ni objetos que podr an quedar atrapados en el arrancador o en otras piezas rotativas Ate para arriba el pelo largo y quite la joyer a A ADVERTENCIA El combustible y sus vapores son 7 y extremadamente inflamables y explosivos lo QS que podr a provocar quemaduras incendios explosiones as como lesiones graves o incluso la muerte CUANDO ANADA COMBUSTIBLE 0 VAC E EL DEP SITO DETENGA el motor del generador y d jelo enfriar durante al menos 2 minutos antes de quitar el tap n de combustible Afloje la tapa lentamente para dejar que la presi n salga del tanque Llene o vac e el dep sito de combustible a la intemperie NO llene demasiado el tanque Permita al menos espacio para la expansi n del combustible Si se ha derramado combustible espere a que se evapore antes de arrancar el motor Mantenga la combustible alejada de chispas llamas abiertas pilotos calor y otras fuentes de ignici n Compruebe frecuentemente que las l neas de combustible el tanque el tap n y los accesorios no est n rotos o tengan fugas C mbielos si es necesario NO encienda un cigarrillo o fume CUANDO PONGA EN FUNCIONAMIENTO EL EQUIPO Compruebe que la buj a el silenciador el tap n del dep sito de combustible y el filtro de aire est n instalados NO arranque el motor sin la buj a instalada CUANDO OPERE EL EQUIPO NO utilice este pr
121. vapors are extremely flammable f and explosive which could cause burns fire EY CS or explosion resulting in death or serious injury WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK Store away from furnaces stoves water heaters clothes dryers or other appliances that have pilot light or other ignition source because they could ignite fuel vapors WHEN DRAINING FUEL Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Drain fuel tank outdoors Keep fuel away from sparks open flames pilot lights heat and other ignition sources Check fuel lines tank cap and fittings frequently for cracks or leaks Replace if necessary DO NOT light a cigarette or smoke Change Engine Oil While engine is still warm drain oil from crankcase Refill with recommended grade See Changing Engine Oil Other Storage Tips 1 DO NOT store fuel from one season to another unless it has been treated as described in Long Term Storage Instructions 2 Replace fuel container if it starts to rust Rust and or dirt in fuel can cause problems if it s used with this unit 3 Cover unit with a suitable protective cover that does not retain moisture A WARNING Storage covers could cause a fire IAN resulting in death or serious injury a DO NOT place a storage cover over a hot generator Let equipment cool for a sufficient time before placing th