1. Hex Nut _ e Install Wheel Kit NOTE Wheel kit is not intended for over the road use You will need the following tools to install these components 1 2 or I3mm wrench Socket wrench with a 1 2 or 13mm socket Pliers Refer to Figure and install the wheel kit as follows Tip generator so that engine end is up 2 Slide axle through both mounting brackets 3 Place a wheel on each side with air valve facing out 4 Place a washer on axle and then place an e ring in axle groove 5 Install e ring with pliers squeezing from top of e ring to bottom of axle 6 Repeat step 3 through 5 to secure second wheel Flat Washer Tip generator so that engine side is down Line up holes in support leg with holes in generator frame 9 Attach support leg using two short M8 x 6mm cap screws and two locking hex nuts Tighten with a 1 2 or 13mm socket and wrench 10 On support leg end of generator slide handle onto center of top of frame Il Attach handle using two long M8 x 45mm cap screws and two locking hex nuts Tighten with a 1 2 or 13mm socket and wrench 12 Return generator to normal operating position resting on wheels and support leg 13 Check that tires are inflated to value marked on tire or within 15 and 40 psi BEFORE STARTING THE ENGINE Add Engine Oil Move generator to a flat level surface Refer to engine owner s manual and follow oil recommendations an
2. DO NOT connect 240 Volt loads to the 120 Volt duplex receptacles DO NOT connect 3 phase loads to the generator DO NOT connect 50 Hz loads to the generator DO NOT OVERLOAD GENERATOR See Don t Overload Generator Stopping the Engine Unplug all electrical loads from generator panel receptacles NEVER start or stop engine with electrical devices plugged in and turned ON 2 Let engine run at no load for several minutes to stabilize internal temperatures of engine and generator 3 Turn engine off according to engine owner s manual 4 Turn red fuel valve to Off position Section 4 Operation RECEPTACLES Receptacles may be marked with rating value greater than generator output capacity NEVER attempt to power a device requiring more amperage than generator or receptacle can supply DO NOT overload the generator See Don t Overload Generator 120 240 Volt AC 30 Amp Locking Receptacle Use a NEMA L14 30 plug with this receptacle Connect a 4 wire cord set rated for 250 Volt AC loads at 30 Amps or greater Figure 5 You can use the same 4 wire cord if you plan to run a 120 Volt load Figure 5 120 240 Volt AC 30 Amp Receptacle 4 Wire Cord Set 240V 120V 94 120V W Neutral DIM vt NEMA L14 30 X Hot Ground Green This receptacle powers 120 240 Volt AC 60 Hz single phase loads requiring up to 5 550 w
3. Section 4 Operation 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load NEVER add more loads than the generator capacity Take special care to consider surge loads in generator capacity as described above Figure 8 Wattage Reference Chart Additional Surge Starting Watts Rated Running Watts Tool or Appliance Essentials Light Bulb 75 watt 75 Deep Freezer 500 500 Sump Pump 800 1200 Refrigerator Freezer 18 Cu Ft 800 1600 Water Well Pump 1 3 HP 1000 2000 Heating Cooling Window AC 10 000 BTU 1200 1800 Window Fan 300 600 Furnace Fan Blower 1 2 HP 800 Kitchen Microwave Oven 1000 Watt 1000 Coffee Maker 1500 Electric Stove Single Element 1500 Hot Plate 2500 Family Room DVD CD Player 100 VCR 100 Stereo Receiver 450 Color Television 27 500 Personal Computer w 7 monitor 800 Other Security System 180 AM FM Clock Radio 300 Garage Door Opener 1 2 HP 480 Electric Water Heater 40 Gallon 4000 DIY Job Site Quartz Halogen Work Light 1000 Airless Sprayer 1 3 HP 600 Reciprocating Saw 960 Electric Drill 1 2 HP 1000 Circular Saw 7 1 4 1500 Miter Saw 10 1800 Table Planer 6 1800 Table Saw Radial Arm Saw 10 2000 Air Compressor 1 2 HP 2500 Wattages listed are approximate only Ch
4. Tanque del Combustible El tanque tiene una capacidad de 5 galones americanos de gasolina sin contenido de plomo Tomacorriente Dobles de 120 Voltios AC 20 Amp Pueden ser utilizados para suministrar alimentaci n el ctrica para el funcionamiento de cargas del motor herramientas aparatos especiales e iluminaci n el ctrica de 120 Voltios AC a 20 Amperios monof sica de 60 Hz Tomacorriente con Dispositivo de Seguridad de 120 240 Voltios 30 Amp Puede ser utilizado para suministrar alimentaci n el ctrica para el funcionamiento de cargas del motor herramientas aparatos especiales e iluminaci n el ctrica de 120 y o 240 Voltios AC a 30 Amperios monof sica de 60 Hz Tuerca Mariposa para Conexi n a Tierra Si requiri consulte con un electricista cualificado un inspector el ctrico o el organismo competente Montaje MONTAJE Su generador requiere de ciertos procedimientos de montaje y solo estar listo para ser utilizado despu s de haberle suministrado servicio con el combustible y aceite recomendados Si usted tiene problemas con el montaje de su generador por favor llame a la l nea de ayuda para generadores al 1 888 611 6708 Para Retirar El Generador De La Caja l Coloque la caja de cart n en una superficie r gida y plana 2 Saque todo el contenido de la caja de cart n a excepci n del generador 3 Abra completamente la caja de cart n cortando cada una de sus esquinas de arriba a
5. 18 pies 800 1600 circulares o refrigeradores Debido a que no todos los c bicos motores se encienden al mismo momento el vataje total de carga se puede estimar al a adir solamente el los aparato s Bomba de aguas 1 3 B 1000 2000 con el vataje adicional m s alto al total del vataje calificado Calefacci n enfriamiento obtenido en el paso 2 Aire Acond de ventana 10 000 BTU 1200 1800 Ventilador de ventana 300 600 Ejemplo Calefactor de caldera 1 2 HP 800 H Vatios Calificados Vatios Adicionales d Cocina erramienta a cuando est ates ACCIONA esoe Horno de microondas 1 000 Vatios 1000 Aparato El ctrico funcionando Carga al encender Cafetera 1500 Aire Acondicionado 1200 1800 Cocina el ctrica Elemento simple 1500 de Ventana Calientaplatos 2500 Refrigerador 800 1600 Habitaci n Familiar Congelador industrial 500 500 Tocador de DVD CD 100 Televisi n 500 VCR 100 Luz 75 Vatios 75 Receptor est reo 450 Total 3075 1800 Vatios de Televisor a color 27 pulg 500 Vatios para funcionar Carga mas alto Computadora personal con monitor de 800 Vataje Total Calificado cuando est funcionando 3075 Vataje de Carga Adicional mas alto 1800 Salida Total Requerida del Generador 4875 Control de la Energia Para prolongar la vida de su generador y los aparatos que est n conectados al mismo es muy importante cuidarlo cuando se le af aden cargas el ctricas Nada deber a estar conectado a los tomacorrientes de
6. NOTA Este motor est certificado para funcionar con gasolina Sistema de control de emisiones de gases de escape EM Modificaciones del motor ADVERTENCIA A Ch La combustible y sus vapores son extremadamente inflamables y explosivos El fuego o una explosi n pueden causar quemaduras M severas e inclusive la muerte CUANDO A ADA COMBUSTIBLE Apague el generador posici n OFF y d jelo enfriar al menos por 2 minutos antes de remover la tapa de la combustible Afloje la tapa lentamente para dejar que la presi n salga del tanque Llene el dep sito de combustible a la intemperie NO llene demasiado el tanque Permita al menos espacio para la expansi n del combustible Mantenga la combustible alejada de chispas llamas abiertas pilotos calor y otras fuentes de ignici n NO encienda un cigarrillo o fume l Utilice combustible normal sin plomo limpia y nueva con un m nimo de 85 octanos NO utilice combustible que contenga metanol ni mezcle aceite con combustible 2 Limpie el rea alrededor de la tapa de llenado del combustible retire la tapa 3 Agregue lentamente combustible regular SIN PLOMO al tanque de combustible Use un embudo para evitar que se derrame Llene el tanque lentamente hasta aproximadamente 1 5 por debajo de la parte la cima del cuello del tubo de llenado Figura 11 Figura Espacio de Combustible 4 Instale la tapa del tanque de combustible y limpie la combustible que
7. TROUBLESHOOTING Problem Cause Solution Circuit breaker is open Reset circuit breaker A Poor connection or defective cord set 2 Check and repair No AC output is available 2 S but engine is running Connected device is bad 3 Connect another device that is in good condition Fault in generator Contact Authorized Service Facility Short circuit in a connected load Disconnect shorted electrical load When loads are Generator is overloaded See Don t Overload Generator connected engine runs good but bogs down Engine speed is too slow Contact Authorized Service Facility Shorted generator circuit Contact Authorized Service Facility Engine shuts down during Out of gasoline Fill fuel tank operation Engine lacks power Load is too high See Don t Overload Generator TROY BILT OWNER WARRANTY POLICY Effective November 2004 LIMITED WARRANTY Troy Bilt is a registered trademark of Troy Bilt LLC and is used under license to Briggs amp Stratton Power Products Briggs amp Stratton Power Products will repair or replace free of charge any part or parts of the equipment that are defective in material or workmanship or both Transportation charges on parts submitted for repair or replacement under this warranty must be borne by purchaser This warranty is effective for the time periods and subject to the conditions provided for in this policy For warranty service find your neares
8. carb n o cal etc Otras exclusiones Tambi n se encuentran excluidos de est garant a el desgaste de los art culos tales como conectadores medidores de aceite correas anillos O filtros empaque de la bomba etc las bombas que se hagan funcionar o trabajar sin agua o da os y malfuncionamientos que resulten de accidentes abusos modificaciones alteraciones un servicio inadecuado congelamiento o deterioro qu mico Los accesorios tales como pistolas mangueras varillas y boquillas est n excluidos de la garant a del producto Esta garant a excluye los fallos debidos a hechos fortuitos y a otros acontecimientos de fuerza mayor que escapan al control del fabricante Tambi n se excluye el equipo usado reacondicionado y destinado a demostraciones el equipo utilizado como fuente principal de energ a en lugar del servicio de la compa a proveedora de electricidad y el equipo destinado a aplicaciones utilizadas para mantener la vida BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A
9. v lida si el dafio al equipo ocurri debido al mal uso falta de mantenimiento adecuado manejo env o almacenamiento o una instalaci n inadecuada De manera similar la garant a queda anulada si se ha borrado la fecha de fabricaci n o el n mero de serie del equipo o si el equipo ha sido alterado o modificado Durante el per odo de la garant a el Comerciante Autorizado del Servicio hace en es la opci n la reparaci n o reemplaza cualquier parte eso sobre el examen se encuentran para ser defectuoso bajo el uso y el servicio normales Esta garant a no cubrir las reparaciones y el equipo siguientes Desgaste normal Equipo el ctrico al aire libre como todos los aparatos mec nicos necesita partes servicio y reemplazo peri dicamente para que funcione bien Esta garant a no cubre la reparaci n cuando el uso normal ha acabado con la vida de una parte en particular o del equipo e Instalaci n y mantenimiento Esta garant a no se aplica al equipo o parte que ha estado sujeta a una instalaci n inadecuada que no haya sido autorizada o a cualquier tipo de alteraci n el mal uso negligencia accidentes sobrecarga velocidad excesiva mantenimiento inadecuado reparaci n o almacenamiento en nuestro juicio han afectado desfavorablemente su rendimiento y fiabilidad Esta garant a tambi n no cubre el mantenimiento normal tales como ajustes limpieza del sistema de combusti n y la obstrucci n debido a materias qu micas suciedad
10. This is the amount of power your generator must produce to keep your items running See Figure 8 3 Estimate how many surge starting watts you will need Surge wattage is the short burst of power needed to start electric motor driven tools or appliances such as a circular saw or refrigerator Because not all motors start at the same time total surge watts can be estimated by adding only the item s with the highest additional surge watts to the total rated watts from step 2 Example Rated Running Tool or Appliance Additional Surge Watts Starting Watts Window Air 1800 Conditioner Refrigerator 1600 Deep Freezer 500 Television Light 75 Watts 3075 Total 1800 Highest Running Watts Surge Watts Total Rated Running Watts 3075 Highest Additional Surge Watts 1800 Total Generator Output Required 4875 Power Management To prolong the life of your generator and attached devices it is important to take care when adding electrical loads to your generator There should be nothing connected to the generator outlets before starting it s engine The correct and safe way to manage generator power is to sequentially add loads as follows l With nothing connected to the generator start the engine as described in this manual 2 Plug in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly
11. in any way CAUTION Exceeding generators wattage amperage capacity can damage generator and or electrical devices connected to it DO NOT check for spark with spark plug removed Running engines produce heat Temperature of muffler and nearby areas can reach or exceed 150 F 65 C Severe burns can occur on contact See Don t Overload Generator Start generator and let engine stabilize before connecting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stopping generator CAUTION Combustible debris such as leaves grass brush etc can catch fire DO NOT touch hot surfaces Allow equipment to cool before touching The generator must be at least 5 feet from structures having combustible walls and or other combustible materials Keep at least 3 feet of clearance on all sides of generator for adequate cooling maintenance and servicing In the State of California a spark arrester is required by law Section 4442 of the California Public Resources Code Other states may have similar laws Federal laws apply on federal lands If you equip the muffler with a spark arrester it must be maintained in effective working order Improper treatment of generator can damage it and shorten its life Use generator only for intended uses If you have questions about intended use ask dealer or call 888 611 67
12. o 23 1 Amperios Corriente a 120 VoltioS 0 oo oo 46 2 Amperios Frecuencia Nominal o o o oo 60Hz a 3600 rpm A EA EREE aa Aa Monof sica Tanque del Combustible 5 Galones Americanos Peso que Embarca 0 2 e eee eee eee eee 169 Ibs RECOMENDACIONES GENERALES DE MANTENIMIENTO El propietario operador es responsable por asegurarse de que todos los trabajos peri dicos de mantenimiento se lleven a cabo adecuadamente que todos los problemas son resueltos y que la unidad se mantiene limpia y adecuadamente almacenada NUNCA opere un generador que est da ado o defectuoso NOTA Debe tiene las preguntas acerca de reemplazar los componentes en su m quina generador de Troy Bilt llaman por favor 1 888 611 6708 para la ayuda Mantenimiento del Motor Consulte el manual del propietario del motor para las instrucciones de c mo mantener adecuadamente el motor A PRECAUCI N Evite el contacto prolongado o repetido de piel con aceite usado de motor El aceite usado del motor ha sido mostrado al cancer de la piel de la causa en ciertos animales del laboratorio Completamente lavado expuso reas con el jab n y el agua MANTENGA FUERA DE ALCANCE DE NINOS NO CONTAMINE CONSERVE los RECURSOS VUELVA ACEITE USADO A la COLECCION CENTRA Mantenimiento del Generador El mantenimiento del generador consiste en conservar la unidad limpia y seca Opere y almacene la unidad en
13. partes o dato El periodo de garant a comienza en la fecha de compra hecha por el primer consumidor al detal o usuario comercial y continua por el periodo de tiempo que aparece en la tabla arriba mencionada Para uso del consumidor significa uso residencial por un consumidor al detal Para uso comercial significa todos los otros casos incluyendo el uso comercial para generar un ingreso o por prop sitos de alquiler Una vez que el equipo ha sido usado comercialmente deber a ser considerado como de uso comercial para las finalidades de esta garant a El motor y las bater as para el encendido est n garantizados por el fabricante de esos productos EL REGISTRO DE LA GARANT A NO ES NECESARIO PARA OBTENER LA GARANT A EN LOS BRIGGS amp STRATTON POWER PRODUCTS GUARDE SU RECIBO DE COMPRA SI USTED NO PROVEE LA PRUEBA DE LA FECHA DE LA COMPRA INICIAL AL MOMENTO EN QUE SE REQUIERA USAR LA GARANT A LA FECHA DE LA FABRICACI N DEL EQUIPO SER USADA PARA DETERMINAR EL PERIODO DE GARANT A Acerca de la seguridad de su equipo Nosotros reciben las reparaciones bajo la garant a y le pide disculpas por cualquier inconveniencia causada Cualquier Concesionario de Servicio Autorizado puede llevar a cabo reparaciones bajo la garant a La mayor a de las reparaciones bajo la garant a son manejadas normalmente pero algunas veces la solicitud del servicio de garant a es posible que no sea apropiada Por ejemplo la garant a no ser
14. proveer el suficiente vataje calificado cuando est funcionando y de carga al encender para los aparatos a los cuales va a proveer la energ a al mismo tiempo Siga estos pasos l Seleccione los aparatos que recibir n la energ a al mismo Secci n 4 Operaci n Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que usted tenga NUNCA a ada m s cargas sobre la capacidad del generador Tome una atenci n especial en considerar las cargas de corriente seg n la capacidad del generador como se describe arriba Figura 7 Guia de Referencia de Vatiaje tiempo Vatios Vatios 2 Totalice los vatios calificados cuando est funcionando de Calificados Adicionales Esta es la cantidad de energ a que su Herramienta o Aparato El ctrico A estos aparatos Es gla q cuando est de Carga al generador debe producir para mantener eso aparatos funcionando encender funcionando adecuadamente Vea la Figura 17 Esenciales 3 Calcule la cantidad de vatios de carga al encender que Bombilla 75 vatios 75 E usted necesitar El vataje de carga es la cantidad m nima de Congelador industrial 500 500 electricidad necesaria para encender herramientas o Bomba de aguas negras 800 1200 aparatos con motores el ctricos tales como sierras 3 E Refrigerador congelador
15. se haya derramado Secci n Operaci n USO DEL GENERADOR Tierra del Sistema El generador dispone de una conexi n a tierra del sistema que conecta los componentes del bastidor a los terminales de tierra de los enchufes hembra de salida de CA La tierra del sistema est conectada al cable de CA neutro que a su vez est conectado al bastidor del generador vea Descripi n del Equipo Requisitos Especiales Es posible que haya normas u ordenanzas locales y nacionales en materia de seguridad e higiene en el trabajo aplicables al uso del generador Consulte con un electricista cualificado un inspector el ctrico o el organismo competente En algunas zonas es obligatorio registrar los generadores en las compa as el ctricas locales Siel generador se utiliza en una obra puede ser necesario cumplir normas y requisitos adicionales Conexi n al Sistema El ctrico de un Edificio Las conexiones a efectos de alimentaci n de reserva al sistema el ctrico de un edificio deben ser realizadas por un electricista cualificado La conexi n debe aislar la alimentaci n del generador de la alimentaci n de la red p blica y debe cumplir todas las leyes y normas el ctricas vigentes ADVERTENCIA Los generadores producen un voltaje muy poderoso Si no a sla el generador de utilidades de energ a puede hacer que los trabajadores de electricidad sufran heridas graves e inclusive la muerte debido a la retroalimentac
16. 08 Operate generator only on level surfaces DO NOT expose generator to excessive moisture dust dirt or corrosive vapors DO NOT insert any objects through cooling slots If connected devices overheat turn them off and disconnect them from generator Shut off generator if electrical output is lost equipment sparks smokes or emits flames unit vibrates excessively Features and Controls KNOW YOUR GENERATOR Section Read this owner s manual and safety rules before operating your generator Compare this illustration with your generator to familiarize yourself with the locations of various controls and adjustments Save this manual for future reference Data Tag Fuel Tank Spark Arrester Muffler Choke Lever Air Cleaner Recoil Starter Rocker Switch on engine shroud 120 Volt AC 20 Amp Duplex Receptacles May be used to supply electrical power for the operation of 120 Volt AC 20 Amp single phase 60 Hz electrical lighting appliance tool and motor loads 120 240 Volt AC 30 Amp Locking Receptacle May be used to supply electrical power for the operation of 120 and or 240 Volt AC 30 Amp single phase 60 Hz electrical lighting appliance tool and motor loads Air Cleaner Protects engine by filtering dust and debris out of intake air Choke Lever Used when starting a cold engine Circuit Breakers AC Push to reset circuit breakers are provided to protect the gene
17. Ambiental Para mayor informaci n acerca de la garant a consulte con el manual del propietario del motor REGLAS DE SEGURIDAD ste es el s mbolo de alerta de seguridad Sirve para advertir al usuario de un posible riesgo para su integridad f sica Siga todos los mensajes de seguridad que figuren despu s de este s mbolo para evitar lesiones o incluso la muerte El s mbolo de alerta de seguridad A es usado con una palabra PELIGRO ADVERTENCIA PRECAUCION un mensaje por escrito o una ilustraci n para alertarlo acerca de cualquier situaci n de peligro que pueda existir PELIGRO indica un riesgo el cual si no se evita causar la muerte o una herida grave ADVERTENCIA indica un riesgo el cual si no se evita puede causar la muerte o una herida grave PRECAUCI N indica un riesgo el cual si no se evita puede causar heridas menores o moderadas PRECAUCI N cuando se usa sin el s mbolo de alerta indica una situaci n que podr a resultar en el dafio del equipo Siga los mensajes de seguridad para evitar o reducir los riesgos de heridas e inclusive la muerte ADVERTENCIA El escape del motor de este producto contiene elementos qu micos reconocidos en el Estado de California por producir c ncer defectos de nacimiento u otros da os de tipo reproductivo S mbolos de Peligro y Significados Descarga El ctrica Fuego Ma D e SW SF 7 Electrocutamiento Explosion Gases T xicos Retroceso Su
18. OTROY BILT Owner s Manual Manual del Propietario Portable Generator Generador Port til Model Modelo 01919 1 IL gum CAUTION PRECAUCION Before using this product read this manual and follow all Antes de utilizar el producto lea este manual y siga todas las Safety Rules and Operating Instructions Reglas de Seguridad e Instrucciones de Uso Questions Preguntas Helpline 1 888 611 6708 M F 8 5 CT Troy Bilt is a registered trademark of Troy Bilt LLC and is used under license to Briggs amp Stratton Power Products Troy Bilt es una marca registrada de Troy Bilt LLC y se usa abajo licencia a Briggs amp Stratton Power Products BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC IA JEFFERSON WISCONSIN U S A 12145 2 24847 Printed in USA Manual No 197126GS Revision 06 20 2005 Safety Rules SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Safety R les sesu screen a Rma es 2 4 Know Your Generator lees eA 5 Assembly us cese raked dre Repas es 6 7 SA e leaden neem e 8 11 Maintenance eser as mada 12 Storages EC a bhawies 13 Troubleshooting 14 Warranty s ico teaser pectet E 15 EQUIPMENT DESCRIPTION Read this manual carefully and become LL familiar with your generator Know its applications its limitations and any hazards involved This manual describes an engine driven revolving field alternating current AC generator designe
19. SEGURIDAD ANTES DE OPERAR SU GENERADOR Compare las ilustraciones con su Generador para familiarizarse con las ubicaciones de los diferentes controles y ajustes Conserve este manual para referencias futuras Etiqueta de Datos Tanque de Combustible TS D Silenciador Apagachispas Palanca del Cebador Depurador de Aire Culatazo el Principio Interruptor Balanc n Cortacircuitos AC Cada tomacorriente posee un cortacircuito para proteger el generador contra sobrecargas el ctricas Los cortacircuitos son del tipo oprimir para reposicionar Culatazo el Principio Us para comenzar motor Depurador de Aire Filtra el aire de entrada a medida que penetra en el motor Etiqueta de Datos Proporciona el modelo revisi n y el n mero de serie de generador Tenga por favor estos prontamente disponible cu ndo llamar para la ayuda Interruptor Balanc n Deber estar en la posici n On En para darle arranque al motor Col quelo en la posici n Off Apagado para detener un motor en funcionamiento Palanca del Cebador Usada cuando se est dando arranque a un motor fr o Silenciador Apagachispas El silenciador disminuye el ruido del motor y est equipado con una pantalla apagachispas Cortacircuitos Tomacorrientes con Dispositivo de Seguridad de 120 240 Voltios AC 30 Amp Tuerca Mariposa para Conexi n aTierra Tomacorrientes Doble de 120 Voltios AC 20 Amp
20. a buj a el silenciador el tap n del dep sito de combustible y el filtro de aire est n instalados NO arranque el motor sin la buj a instalada Si se ha derramado combustible espere a que se evapore antes de arrancar el motor CUANDO OPERE EL EQUIPO NO incline el motor o el equipo de tal manera que la combustible se pueda derramar Este generador no es apto para el uso en equipos m viles ni en aplicaciones marinas CUANDO TRANSPORTE O REPARE EL EQUIPO Transporte o repare el equipo con el tanque de combustible vac o o con la v lvula para apagar el combustible apagada posici n OFF Desconecte el cable de la buj a CUANDO ALMACENE O GUARDE EL EQUIPO CON COMBUSTIBLE EN ELTANQUE Almacene alejado de calderas estufas calentadores de agua secadoras de ropa u otros aparatos electrodom sticos que posean pilotos u otras fuentes de ignici n porque ellos pueden encender los vapores de la combustible A ADVERTENCIA Este generador no cumple la norma 33CFR 183 del cuerpo de guardacostas de EE UU y no debe utilizarse en aplicaciones marinas El uso de un generador no homologado por cuerpo de guardacostas de EE UU puede provocar lesiones y dafios materiales Secci n 1 Instrucciones de Seguridad A ADVERTENCIA CL Y Chispear involuntario puede tener como resultado el fuego o el golpe el ctrico CUANDO AJUSTE O HAGA REPARACIONES A SU GENERADOR Siempre desconecte el alambre de la buj a y
21. alida est protegida por un corto circuito de del tipo empuje para reposicionar 120 Volt AC 20 Amp Recept culos Dobles Cada recept culo Figura 15 est protegido en contra de sobrecargas por un corto circuitos de del tipo empuje para reposicionar Figura 15 120 Volt AC 20 Amp Recept culo Doble Use cada recept culo para operar 120 Voltios AC de fase sencilla de cargas de 60Hz que requieren hasta 2 400 vatios 2 4 kW a corrientes de 20 Amps Use los juegos de cables que son calificados para cargas de 125 Voltios AC a 20 Amps o mayores JUEGO DE CABLES DEL ADAPTADOR DEL GENERADOR El generador est equipado con un Juego de Cables del Adaptador del Generador de 25 pies disefiado para un circuito neutro a tierra de 240 voltios 30 Amperios Figura 16 El juego de cables del adaptador del generador provee un suministro conveniente de energ a para cualquier emergencia en su propiedad de tal manera que su generador pueda ser operado seguramente en el exterior Figura 16 Juego de Cables del Adaptador del Generador La carga maxima en cada tomacorriente es de 20 Amperios La carga maxima total tanto en el tomacorriente de cable amarillo como el tomacorriente de cable negro es de 30 Amperios NOTA Siga todas las instrucciones de seguridad cuando conecte cualquier cable de extensi n o aparato al generador NO SOBRECARGUE GENERADOR Capacidad Usted debe asegurarse que su generador puede
22. atts of power 5 55 kW at 23 1 Amps for 120 Volts or 240 Volts The outlet is protected by a push to reset circuit breaker 120 Volt AC 20 Amp Duplex Receptacles Each duplex receptacle Figure 6 is protected against overload by a push to reset circuit breaker Figure 6 120 Volt 20 Amp Duplex Receptacle Use each receptacle to operate 120 Volt AC single phase 60 Hz electrical loads requiring up to 2 400 watts 2 4 kW at 20 Amps of current Use cord sets that are rated for 125 Volt AC loads at 20 Amps or greater GENERATOR ADAPTER CORD SET The generator is equipped with a 25 generator adapter cord set designed for a 240 Volt 30 Amp grounded neutral circuit Figure 7 The generator adapter cord set provides a convenient supply of emergency power into your dwelling so that your generator can be operated safely outside Figure 7 Generator Adapter Cord Set The maximum load on each outlet is 20 Amps The maximum total load on both yellow wire outlets or black wire outlets is 30 Amps NOTE Follow all safety precautions when connecting any extension cord or device to the generator am DON T OVERLOAD GENERATOR Capacity You must make sure your generator can supply enough rated running and surge starting watts for the items you will power at the same time Follow these simple steps l Select the items you will power at the same time 2 Total the rated running watts of these items
23. bajo 4 Mantenga el generador sobre el cart n para instalar el juego de ruedas Figura 10 Instale el Juego de Ruedas Tornillos Tuercas Instale el Juego de Ruedas NOTA Este Juego de Ruedas no ha sido dise ado para ser usado en la carretera Necesitar las siguientes herramientas para instalar estos componentes e Llave de 1 2 13 mm Llave de cubo de 1 2 13 mm Alicates Consulte la Figura 10 e instale el juego de ruedas conforme a las instrucciones siguientes Dele la vuelta al generador de forma que el motor quede arriba 2 Introduzca el eje a trav s de los dos soportes de montaje 3 Coloque una rueda en cada extremo con la v lvula de aire hacia el exterior 4 Introduzca una arandela por el eje y coloque una anilla en 66 09 e en la ranura del eje 5 Para ello apriete con unos alicates desde la parte superior de la anilla en e hacia la parte inferior del eje Arandela Tornillos Pata de Apoyo Tuercas Repita los pasos del 3 al 5 para asegurar la segunda rueda 7 Dele la vuelta al generador de forma que el lado del motor quede abajo 8 Haga coincidir los orificios de la pata de apoyo con los del bastidor del generador 9 Monte la pata de apoyo con dos tornillos de cabeza cortos M8 x 16 mm y dos tuercas hexagonales Apriete con una llave de cubo de 1 2 13 mm 10 En el lado de la pata de sop
24. col quelo donde no pueda entrar en contacto con la buj a CUANDO PRUEBE LA BUJ A DEL MOTOR Utilice un comprobador de buj as homologado NO comprueba la chispa sin la buj a instalada A ADVERTENCIA Los motores al funcionar producen calor La temperatura del silenciador y de las reas cercanas puede alcanzar o pasar los 150 F 65 C Quemaduras severas pueden ocurrir al hacer contacto Los residuos como hojas hierba maleza etc se pueden inflamar NO toque las superficies calientes Permita que el equipo se enfr e antes de tocarlo El generador debe estar situado a un m nimo de 152 cm 5 pies de toda estructura con muros combustibles y o otras materias combustibles Mantenga un m nimo de 92 cm 3 pies alrededor de la carcasa del generador para facilitar la ventilaci n y el mantenimiento del generador En el estado de California es obligatorio seg n la ley el uso de apagachispas Secci n 4442 del C digo de Recursos P blicos de California Otros estados pueden tener leyes similares Las leyes federales se aplican en tierras federales Si equipa el silenciador con un apagachispas este deber ser mantenido en buenas condiciones de trabajo A PRECAUCI N Las velocidades de operaci n en exceso aumentan los riesgos de heridas y da os al generador Las velocidades bajan en exceso imponen una carga muy pesada NO cambie ninguna velocidad determinada El generador suministra una frecuencia y un
25. d instructions CAUTION Any attempt to crank or start the engine before it has been properly filled with the recommended oil will result in equipment failure Refer to engine manual for oil fill information Damage to equipment resulting from failure to follow this instruction will void warranty NOTE Check oil often during engine break in Refer to engine owner s manual for recommendations NOTE The generator assembly rotates on a prelubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing Section 5 Assembly Add Fuel NOTE This gasoline engine is certified to operate on gasoline Exhaust Emission Control System EM Engine Modifications iy Fuel and its vapors are extremely flammable and y explosive Fire or explosion can cause severe burns or death WHEN ADDING FUEL Turn generator OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fill fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion Keep fuel away from sparks open flames pilot lights heat and other ignition sources DO NOT light a cigarette or smoke Use clean fresh regular UNLEADED fuel with a minimum of 85 octane DO NOT use fuel which contains Methanol DO NOT mix oil with fuel 2 Clean area around fuel fill cap remove cap Slowly add regular unleaded fuel to fuel tank Be careful not to
26. d to supply electrical power for operating compatible electrical lighting appliances tools and motor loads The generator s revolving field is driven at about 3 600 rpm by a single cylinder engine CAUTION DO NOT exceed the generator s wattage amperage capacity See Don t Overload Generator Every effort has been made to ensure that information in this manual is accurate and current However we reserve the right to change alter or otherwise improve the product and this document at any time without prior notice The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency For warranty information refer to the engine owner s manual Copyright O 2005 Briggs amp Stratton Power Products Group LLC All rights reserved No part of this material may be reproduced or transmitted in any form by any means without the express written permission of Briggs amp Stratton Power Products Group LLC SAFETY RULES This is the safety alert symbol It is used to A alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death The safety alert symbol is used with a signal word DANGER CAUTION WARNING a pictorial and or a safety message to alert you to hazards DANGER indicates a hazard which if not avoided will result in death or serious injury WARNING indicates a hazard which if not avoided could
27. eck tool or appliance for actual wattage 4 Maintenance SPECIFICATIONS Starting Watts isis seo eges 8 550 watts Wattage i usesencesale nde cos 5 550 watts AC Load Current At 120 Volts gc ep Er Rs 46 2 Amps At 240 Volts sl pr eR 23 1 Amps Ph se obere eR Deacon eae Kc eae phase Rated Frequency cece wesc eee 60 Hertz Fuel Tank Capacity o oooooooo 5 U S gallons Shipping Weight o oooocooccomo oo 169 Ibs GENERAL MAINTENANCE RECOMMENDATIONS The Owner Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis that all discrepancies are corrected and that the unit is kept clean and properly stored NEVER operate a damaged or defective generator Should you have questions about replacing components on your Troy Bilt generator please call 1 888 611 6708 for assistance Engine Maintenance See engine owner s manual for instructions Avoid prolonged or repeated skin contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Generator Maintenance Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust d
28. en Para Limpiar el Generador Revise que las ranuras para el aire de enfriamiento y las aperturas del generador se encuentren abiertas y despejadas ADVERTENCIA Las cubiertas para almacenamiento pueden ser inflamables NO coloque una cubierta encima de un generador caliente Deje que la unidad se enfr e lo suficientemente antes de que le coloque la cubierta Almacenando el Motor Consulte el manual del propietario del motor para las instrucciones de c mo preparar adecuadamente el motor para su almacenamiento Otras Sugerencias Para el Almacenando Para prevenir que se forme una resina en el sistema de combustible o en partes esenciales del carburador vac e estabilizadores del combustible suministrados en el tanque de gasolina y llene con gasolina fresca Haga funcionar la unidad por algunos minutos para hacer circular el aditivo a trav s del carburador La unidad y el combustible pueden ser almacenados hasta por 24 meses Se puede comprar m s estabilizador del combustible en su tienda local NO almacene gasolina de una estaci n a otra estaci n al menos que haya sido tratada como se mencion antes Reemplace la caneca de gasolina si comienza a oxidarse El xido y o la suciedad en la gasolina le causar problemas Almacene la unidad en un rea limpia y seca Problemo El interruptor autom tico de circuito est abierto Conexi n mal o defectuosa del juego de No hay corriente a
29. er repair when normal use has exhausted the life of a part or the equipment Installation and Maintenance This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized installation or alteration and modification misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in our judgment to adversely affect its performance and reliability This warranty also does not cover normal maintenance such as adjustments fuel system cleaning and obstruction due to chemical dirt carbon or lime etc Other Exclusions Also excluded from this warranty are wear items such as quick couplers oil gauges belts o rings filters pump packing etc pumps which have been run without water supplied or damage or malfunctions resulting from accidents abuse modifications alterations or improper servicing or freezing or chemical deterioration Accessory parts such as guns hoses wands and nozzles are excluded from the product warranty This warranty excludes failures due to acts of God and other force majeure events beyond the manufacturers control Also excluded is used reconditioned and demonstration equipment equipment used for prime power in place of utility power and equipment used in life support applications BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A Reglas de Seguridad CONSERVE ESTAS INSTRUCCIONES TABLA DE CONTENIDOS Re
30. glas De Seguridad osse er br php S 16 18 Conozca Su Generador 0 ccc cece el llle 19 Montaje kk Lec Maas e e e e eee qe 20 21 Operaci n 1 eb cite dea ERE gaps a Ve e ge 22 25 MarnitenimletitO z uecpoelieseeciceer 9er9erQb5a ve ida 26 Almacenamiento oer bu Lex ELSE XS 27 Diagnosticos De Aver as llle eese 27 Galahtla s os eet nde sdb at auto do atat 28 DESCRIPCI N DEL EQUIPO Lea este manual de manera cuidadosa y LL familiar cese con su generador Conozca sus usos sus limitaciones y cualquier peligro relacionado con el mismo Este generador funciona en base a un motor de campo el ctrico giratorio y de corriente alterna AC Fue dise ado con la finalidad de proveer energ a el ctrica para luces el ctricas aparatos herramientas compatibles y cargas de motor El campo giratorio del generador funciona a una velocidad de 3 6000 rpm usando un motor con un solo cilindro PRECAUCI N NO sobrepase la capacidad de vataje y amperaje del generador Revise No Sobrecargue el Generador Se ha hecho cada esfuerzo posible para asegurarse que la informaci n que aparece en este manual es exacta y se encuentra actualizada Sin embargo nosotros se reserva el derecho a cambiar alterar o de otra manera mejorar el producto y este documento en cualquier momento sin previo aviso El Sistema de Control de Emisiones para este generador est garantizado para juegos est ndares por la Agencia de Protecci n
31. h as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator A WARNING Rapid retraction of starter cord kickback will pull hand and arm toward engine faster than Ma you can let go Broken bones fractures bruises or sprains could result When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback NEVER start or stop engine with electrical devices plugged in and turned on Section 1 Safety Rules fut Fuel and its vapors are extremely flammable and y explosive Fire or explosion can cause severe burns or death WHEN ADDING OR DRAINING FUEL Turn generator OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fill or drain fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion Keep fuel away from sparks open flames pilot lights heat and other ignition sources DO NOT light a cigarette or smoke WHEN STARTING EQUIPMENT Ensure spark plug muffler fuel cap and air cleaner are in place DO NOT crank engine with spark plug removed If fuel spi
32. i n de la energ a el ctrica Cuando use un generador como poder de energ a auxiliar notifique a la compa a de utilidades Use el equipo de transferencia aprobado para aislar el generador de otra utilidad el ctrica Use un interruptor para la falla del circuito de tierra GFCI en cualquier rea bastante h meda o que sea altamente conductiva tales como terrazas de metal o trabajo hecho con acero NO toque los alambres pelados o recept culos NO use un generador con cables el ctricos que est n malgastados rotos pelados o da ados de cualquier forma NO opere el generador bajo la lluvia NO maneje el generador o cables el ctricos mientras est parado en agua descalzo o cuando las manos y los pies est n mojados NO permita que personas descalificadas o ni os operen o sirvan al generador Ubicaci n del Generador Espacio Libre Alrededor del Generador ADVERTENCIA Al generador funcionar se produce mon xido de carbono un gas inodoro y venenoso El respirar el mon xido de carbono producir n usea desmayo o la muerte Opere el generador SOLAMENTE al aire libre Aseg rese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaci n u otras aberturas en un espacio cerrado en el que puedan acumularse NO opere el generador dentro de un edificio o lugar cerrado incluyendo el compartimiento del generador en un veh culo recreativo o RV El generador debe estar situad
33. iedad y residuos sueltos Puede usar aire a baja presi n que no exceda los 25 psi para eliminar la suciedad Inspeccione las ranuras para aire de enfriamiento y la apertura del generador Estas aperturas deber n mantenerse limpias y despejadas Etiqueta de Datos Localice la etiqueta de datos del generador y copie la informaci n en el espacio disponible a continuaci n Esta informaci n es fundamental para poder recibir ayuda de nuestro departamento de servicio al cliente o de un distribuidor de servicio autorizado La etiqueta de datos Figura 18 que contiene los n meros de modelo revisi n y de serie est situada en la protecci n t rmica o apoyo del motor del lateral del silenciador del generador Copie los n meros de modelo revisi n y de serie del generador en el espacio disponible a continuaci n para futuras consultas Figura 18 Etiqueta de Datos Copie aqu el n mero Copie aqu PT al revisi n LOL O Copie aqu el n mero de serie MODEL REV NO SERIAL Almacenamiento amp Diagnosticos de Aver as ALMACENAMIENTO El generador deber ser encendido al menos una vez cada siete d as y deber dejarlo funcionar al menos durante 30 minutos Si no puede hacer esto y debe almacenar la unidad por m s de 30 d as siga las siguientes instrucciones para preparar su unidad para almacenamiento Almacenando el Generador Limpie el generador como est descrito
34. irt moisture or any corrosive vapors Cooling air slots in the generator must not become clogged with snow leaves or any other foreign material NOTE DO NOT use a garden hose to clean generator Water can enter engine fuel system and cause problems In addition if water enters generator through cooling air slots some of the water will be retained in voids and cracks of the rotor and stator winding insulation Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings Generator Cleaning Use a damp cloth to wipe exterior surfaces clean CAUTION Improper treatment of generator can damage it and shorten its life DO NOT expose generator to excessive moisture dust dirt or corrosive vapors DO NOT insert any objects through cooling slots Use a soft bristle brush to loosen caked on dirt or oil Use a vacuum cleaner to pick up loose dirt and debris Use low pressure air not to exceed 25 psi to blow away dirt Inspect cooling air slots and opening on generator These openings must be kept clean and unobstructed Data Tag Data tag information is very important if you need help from our Customer Service Department or an authorized service dealer The data tag Figure 9 is located either on the heat shield or engine support on the muffler side of the generator For future reference please copy the model revision and serial number of the generat
35. kup power notify utility company Use approved transfer equipment to isolate generator from electric utility Use a ground fault circuit interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator Generator Location Generator Clearance A WARNING Running generator gives off carbon monoxide an odorless colorless poison gas Breathing carbon monoxide will cause nausea fainting or death Operate generator ONLY outdoors Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other openings DO NOT operate generator inside any building or enclosure including the generator compartment of a recreational vehicle RV The generator must be at least 5 ft 152 cm from structures having combustible walls and or other combustible materials Leave at least 3 ft 92 cm all around generator including overhead for adequate cooling maintenance and servicing Place generator in a well ventilated area which will allow for removal of deadly exhaust gas DO NOT place generator where exhaust ga
36. l generador antes de que su motor sea encendido La forma correcta y m s segura para controlar la energ a del generador es la de a adir en secuencias las cargas como se describe a continuaci n Sin tener nada conectado al generador encienda el motor de la manera descrita en este manual 2 Conecte y encienda la primera carga preferiblemente la mayor que usted tenga 3 Permita que la salida del generador se estabilice el motor funciona suavemente y el aparato conectado al mismo trabaja adecuadamente 17 pulg Otros Sistema de seguridad Radio Reloj AM FM Abridor de garaje 1 2 HP Calentador el ctrico de agua 40 galones Taller Luz de hal geno para trabajar Rociador sin aire 1 3 HP Sierra intercambiable Taladro el ctrico 1 2 HP Sierra circular 7 4 pulg Sierra inglete 10 pulg Mesa de planificaci n 6 pulg Sierra de mesa sierra de brazo radial 10 pulg Compresor de aire 1 2 HP HP Caballo de fuerza El vataje que aparece en la lista es solamente una cantidad aproximada Verifique la herramienta o aparato el ctrico para obtener el vataje verdadero Mantenimiento ESPECIFICACIONES Potencia Empezar 8 550 Vatios 8 55 kW Potencia c sse neda RE EE ae 5 550 Vatios 5 55 kW Voltaje Nominal AC 0 2 2 0 eee eee eee 120 240 Voltios Corriente a 240 Voltios oo oooooo
37. lls wait until it evaporates before starting engine WHEN OPERATING EQUIPMENT Do not tip engine or equipment at angle which causes fuel to spill This generator is not for use in mobile equipment or marine applications WHEN TRANSPORTING OR REPAIRING EQUIPMENT Transport repair with fuel tank EMPTY or with fuel shutoff valve OFF Disconnect spark plug wire WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK Store away from furnaces stoves water heaters clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors This generator does not meet U S Coast Guard Regulation 33CFR 183 and should not be used on marine applications Failure to use the appropriate U S Coast Guard approved generator could result in bodily injury and or property damage Section 1 Safety Rules AA CAUTION y Excessively high operating speeds increase risk of injury and damage to generator Unintentional sparking can result in fire or DO NOT tamper with governed speed Generator supplies electric shock correct rated frequency and voltage when running at governed WHEN ADJUSTING OR MAKING REPAIRS TO YOUR speed GENERATOR Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester Excessively low speeds impose a heavy load DO NOT modify generator
38. lterna cables pero el motor funciona Aver a en el generador Corto circuito en una de las cargas conectadas Cuando las cargas est n conectadas el motor funciona correctamente pero se ahoga Circuito del generador en corto El motor se apaga en pleno funcionamiento Sin gasolina Al motor le hace falta potencia La carga es muy alta El dispositivo conectado est dafiado El generador est sobrecarga Velocidad del motor es muy lenta Reposicione el interruptor Revise y repare Conecte otro dispositivo que est buenas condiciones P ngase en contacto con el servicio t cnico autorizado Desconecte la carga el ctrica en corto Vea No Sobrerecarque Generador P ngase en contacto con el servicio t cnico autorizado P ngase en contacto con el servicio t cnico autorizado Llene el tanque de combustible Vea No Sobrerecarque el Generador POL TICA PARA EL PROPIETARIO DE EQUIPOS TROY BILT Efectiva desde el ro de Noviembre 2004 GARANTIA LIMITADA Troy Bilt amp es una marca registrada de Troy Bilt LLC bajo licencia de Briggs amp Stratton Power Products Briggs amp Stratton Power Products reparar o sustituir sin cargo alguno cualquier componente del equipo que presente defectos de materiales ylo mano de obra Los gastos de transporte de las piezas enviadas para reparar o sustituir conforme a los t rminos de esta garant a correr n a cargo del comprador E
39. motor con todos los dispositivos el ctricos conectados y encendidos 2 Deje que el motor funcione sin cargas por algunos minutos para estabilizar las temperaturas internas del motor y el generador 3 Pare el motor tal y como se explica en el manual del propietario del motor 4 Cierre la v lvula del combustible Secci n 4 Operaci n RECEPT CULOS A PRECAUCI N El valor nominal que se indica en los enchufes hembra puede ser superior a la capacidad de salida del generador NUNCA intente suministrar corriente a un dispositivo de amperaje superior al que puede suministrar el generador o el enchufe hembra NO sobrecargue el generador Consulte el apartado No Sobrecargue Generador 120 240 Voltios AC 30 Amp Recept culo de Seguridad Use un tap n NEMA L14 30 con este recept culo Conecte un juego de cable de 4 alambres clasificado como 250 Voltios AC a 30 Amps o mayor Figura 14 Usted puede usar el mismo cable de 4 alambres si planea trabajar con una carga de 120 Voltios Figura 14 120 240 Volt AC 30 Amp Recept culo de Seguridad Juego de Cable de 4 Alambres 120 W Neutro 120V i l Y Cargado X Cargado NEMA LI 4 30 A Tierra Verde Este recept culo le provee poder a cargas de 120 240 Voltios AC de 60 Hz fase sencilla que requieren hasta 5 550 vatios de energ a 5 55 kW a 23 1 Amps para 120 Voltios o 240 Voltios La s
40. o a un m nimo de 152 cm 5 pies de toda estructura con muros combustibles y o otras materias combustibles Mantenga un m nimo de 92 cm 3 pies alrededor del generador incluido la parte superior para facilitar la ventilaci n y el mantenimiento del generador Sit e el generador en una zona bien ventilada que permita la eliminaci n de los gases de escape mortales NO instale el generador en lugares en los que los gases de escape se puedan acumular o entrar en un edificio que pueda estar ocupado Aseg rese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaci n u otras aberturas en un espacio cerrado en el que puedan acumularse Figura 12 Tenga en cuenta los vientos y las corriente de aire preponderantes cuando elija la ubicaci n del generador Figura 12 Espacio Libre Alrededor del Generador OPERANDO EL GENERADOR PRECAUCION El sobrepasar la capacidad del amperaje y vataje del generador puede dafiar al generador y los aparatos el ctricos conectados al mismo Vea No sobrecargue generador Encienda su generador y deje que el motor se estabilice antes de conectar las cargas el ctricas Conecte las cargas el ctricas en la posici n de apagado OFF luego encienda ON para su operaci n Apague OFF las cargas el ctricas y descon ctelas del generador antes de parar el generador Encienda el Motor Desconecte todas las cargas el ctricas del generador Use las sig
41. or in the space below Copy Model Number Here MODEL Copy Revision SERIAL I Copy Serial Number Here v Storage Section STORAGE Engine Storage See engine owner s manual for instructions The generator should be started at least once every seven days and allowed to run at least 30 minutes If this cannot be done and you must store the unit for more than Other Storage Tips 30 days use the following guidelines to prepare it for To prevent gum from forming in fuel system or on storage essential carburetor parts add fuel stabilizer into fuel tank and fill with fresh fuel Run the unit for several Generator Storage minutes to circulate the additive through the carburetor The unit and fuel can then be stored for up to 24 months Fuel stabilizer can be purchased locally Clean the generator as outlined in Generator Cleaning Check that cooling air slots and openings on generator DO NOT store fuel from one season to another unless are open and unobstructed it has been treated as described above la WARNING Replace fuel container if it starts to rust Rust and or dirt MM in fuel can cause problems if it s used with this unit Storage covers can be flammable Store unit in a clean and dry area DO NOT place a storage cover over a hot generator Let equipment cool for a sufficient time before placing the cover on the equipment wana Troubleshooting 7
42. orte del generador introduzca el asa en el centro de la parte superior del bastidor II Fije el asa con dos tornillos de cabeza largos M8 x 45 mm y dos tuercas hexagonales Apriete con una llave de cubo de 1 2 6 13 mm 12 Vuelva a colocar el generador en la posici n normal de funcionamiento apoyado en las ruedas y la pata de apoyo 13 Compruebe que las ruedas est n infladas conforme al valor indicado en el neum tico o entre 15 y 40 psi ANTES DE DARLE ARRANQUE AL MOTOR Agregar Aceite al Motor e Coloque la generador sobre una superficie nivelada PRECAUCI N Cualquier intento para arancar el motor antes de haberle proporcionado el mantenimiento apropiado con el aceite recomendado podr a ocasionar la falla del motor Consulte el manual del propietario del motor para afiadir al motor el aceite recomendado El dafio a la lavadora a presi n resultado de la desatenci n a esta precauci n no ser cubierto por la garant a Consulte el manual del propietario del motor para afiadir al motor el aceite recomendado NOTA Verifique el aceite del motor de manera frecuente cuando ste se esfuerce demasiado Consulte el manual del propietario del motor para conocer cu les son las recomendaciones al respecto NOTA El campo giratorio del generador se encuentra en un cojinete pre lubricado y sellado que no requiere lubricaci n adicional por la vida til del cojinete Secci n 3 Montaje Agregue Combustible
43. overfill Allow about 1 5 of tank space for fuel expansion Figure 2 Figure 2 Fuel Expansion 4 Install fuel cap and wipe up any spilled fuel Operation USING THE GENERATOR System Ground The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles The system ground is connected to the AC neutral wire see Equipment Description earlier in this manual Special Requirements There may be Federal or State Occupational Safety and Health Administration OSHA regulations local codes or ordinances that apply to the intended use of the generator Please consult a qualified electrician electrical inspector or the local agency having jurisdiction In some areas generators are required to be registered with local utility companies If the generator is used at a construction site there may be additional regulations which must be observed Connecting to a Building s Electrical System Connections for standby power to a building s electrical system must be made by a qualified electrician The connection must isolate the generator power from utility power and must comply with all applicable laws and electrical codes A WARNING Generator produces powerful voltage Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy When using generator for bac
44. perficie Caliente Secci n 1 Reglas de Seguridad A ADVERTENCIA Al generador funcionar se produce monoxido de carbono un gas inodoro y venenoso El respirar el mon xido de carbono producir n usea desmayo o la muerte Opere el generador SOLAMENTE al aire libre Aseg rese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaci n u otras aberturas en un espacio cerrado en el que puedan acumularse NO opere el generador dentro de un edificio o lugar cerrado incluyendo el compartimiento del generador en un veh culo recreativo o RV A ADVERTENCIA Los generadores producen un voltaje muy poderoso Si no a sla el generador de utilidades de energ a puede hacer que los trabajadores de electricidad sufran heridas graves e inclusive la muerte debido a la retroalimentaci n de la energ a el ctrica Cuando use un generador como poder de energ a auxiliar notifique a la compa a de utilidades Use el equipo de transferencia aprobado para aislar el generador de otra utilidad el ctrica Use un interruptor para la falla del circuito de tierra GFCI en cualquier rea bastante h meda o que sea altamente conductiva tales como terrazas de metal o trabajo hecho con acero NO toque los alambres pelados o recept culos NO use un generador con cables el ctricos que est n malgastados rotos pelados o da ados de cualquier forma NO opere el generador bajo la lluvia NO maneje el gene
45. rador o cables el ctricos mientras est parado en agua descalzo o cuando las manos y los pies est n mojados NO permita que personas descalificadas o ni os operen o sirvan al generador ADVERTENCIA El r pido repliegue del cable del arrancador retroceso impedir que el usuario suelte el cable a tiempo y tirar de su mano y brazo hacia el motor Como resultado podr an producirse fracturas contusiones o esguinces Cuando arranque el motor tire lentamente del cable hasta sentir una resistencia y a continuaci n tire r pidamente de l para evitar su retroceso NUNCA arranque o pare el motor cuando haya aparatos el ctricos conectados y en funcionamiento A ADVERTENCIA kk La combustible y sus vapores son extremadamente inflamables y explosivos El fuego o una explosi n pueden causar quemaduras M severas e inclusive la muerte CUANDO A ADA COMBUSTIBLE O VAC E EL DEP SITO Apague el generador posici n OFF y d jelo enfriar al menos por 2 minutos antes de remover la tapa de la combustible Afloje la tapa lentamente para dejar que la presi n salga del tanque Llene o vac e el dep sito de combustible a la intemperie NO llene demasiado el tanque Permita al menos espacio para la expansi n del combustible Mantenga la combustible alejada de chispas llamas abiertas pilotos calor y otras fuentes de ignici n NO encienda un cigarrillo o fume CUANDO PONGA EN FUNCIONAMIENTO EL EQUIPO Compruebe que l
46. rator against electrical overload Circuit Breakers AC 120 240 Volt AC 30 Amp Receptacle EZ ae Grounding Fastener 120 Volt AC 20 Amp Duplex Receptacles Oil Fill Data Tag Provides model revision and serial number of generator Please have these readily available when calling for assistance Fuel Tank Capacity of five 5 U S gallons Grounding Fastener If required please consult a qualified electrician electrical inspector or local agency having jurisdiction Oil Fill Add engine oil here Recoil starter Used to start the engine Rocker Switch Set this switch to On before using recoil starter Set switch to Off to switch off engine Spark Arrester Muffler Exhaust muffler lowers engine noise and is equipped with a spark arrester screen a Assembly ASSEMBLY Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended oil and fuel If you have any problems with the assembly of your generator please call the generator helpline at 1 888 611 6708 Remove Generator From Carton l Setthe carton on a rigid flat surface 2 Remove everything from carton except generator Open carton completely by cutting each corner from top to bottom 4 Leave generator on carton to install wheel kit Figure Install Wheel Kit Cap Screw Handle Assembly Hex Nut 9
47. result in death or serious injury CAUTION indicates a hazard which if not avoided might result in minor or moderate injury CAUTION when used without the alert symbol indicates a situation that could result in equipment damage Follow safety messages to avoid or reduce the risk of injury or death The engine exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Hazard Symbols and Meanings Dr Electrocution Electrical Shock Explosion Fire y Toxic Fumes Kickback 9 77 Hot Surface a A WARNING Running generator gives off carbon monoxide an odorless colorless poison gas Breathing carbon monoxide will cause nausea fainting or death Operate generator ONLY outdoors Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other openings DO NOT operate generator inside any building or enclosure including the generator compartment of a recreational vehicle RV A WARNING Generator produces powerful voltage Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy When using generator for backup power notify utility company Use approved transfer equipment to isolate generator from electric utility Use a ground circuit fault interrupter GFCI in any damp or highly conductive area suc
48. rting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback NEVER start or stop engine with electrical devices plugged in and turned on Section 4 Operation NOTE If engine starts but fails to run or if unit shuts down during operation make sure unit is on a level surface and check for proper oil level in crankcase This unit may be equipped with a low oil protection device See engine manual A WARNING Running engines produce heat Temperature of muffler and nearby areas can reach or exceed 150 F 65 C Severe burns can occur on contact Combustible debris such as leaves grass brush etc can catch fire DO NOT touch hot surfaces Allow equipment to cool before touching The generator must be at least 5 feet from structures having combustible walls and or other combustible materials Keep at least 3 feet of clearance on all sides of generator for adequate cooling maintenance and servicing In the State of California a spark arrester is required by law Section 4442 of the California Public Resources Code Other states may have similar laws Federal laws apply on federal lands If you equip the muffler with a spark arrester it must be maintained in effective working order Connecting Electrical Loads Let engine stabilize and warm up for a few minutes after starting Plug in and turn on the desired 120 and or 240 Volt AC single phase 60 Hz electrical loads
49. s could accumulate and enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes or other openings that can allow exhaust gas to collect in a confined area Figure 3 Prevailing winds and air currents should be taken into consideration when positioning generator Figure 3 Generator Clearance Exhaust Port OPERATING THE GENERATOR CAUTION Exceeding generators wattage amperage capacity can damage generator and or electrical devices connected to it See Don t Overload Generator Start generator and let engine stabilize before connecting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stopping generator Starting the Engine Disconnect all electrical loads from the generator Use the following start instructions Make sure unit is on a level surface IMPORTANT Failure to start and operate unit on a level surface will cause the unit not to start or shut down during operation 2 Turn red fuel valve to On position Figure 4 Figure 4 Fuel Valve 3 Start engine according to instructions given in engine owner s manual A WARNING Rapid retraction of starter cord kickback will pull hand and arm toward engine faster than you can let go Broken bones fractures bruises or sprains could result When sta
50. s of this warranty The engine and starting batteries are warranted solely by the manufacturers of those products WARRANTY REGISTRATION IS NOT NECESSARY TO OBTAIN WARRANTY ON BRIGGS amp STRATTON POWER PRODUCTS EQUIPMENT SAVE YOUR PROOF OF PURCHASE RECEIPT IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED THE MANUFACTURING DATE OF THE EQUIPMENT WILL BE USED TO DETERMINE THEWARRANTY PERIOD About your equipment warranty We welcome warranty repair and apologize to you for being inconvenienced Any Authorized service dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may not be appropriate For example warranty service would not apply if equipment damage occurred because of misuse lack of routine maintenance shipping handling warehousing or improper installation Similarly the warranty is void if the manufacturing date or the serial number on the equipment has been removed or the equipment has been altered or modified During the warranty period the Authorized service dealer at its option will repair or replace any part that upon examination is found to be defective under normal use and service This warranty will not cover following repairs and equipment Normal Wear Outdoor power equipment like all mechanical devices needs periodic parts service and replacement to perform well This warranty does not cov
51. sar los 150 F 65 C Quemaduras severas pueden ocurrir al hacer contacto Los residuos como hojas hierba maleza etc se pueden inflamar NO toque las superficies calientes Permita que el equipo se enfr e antes de tocarlo El generador debe estar situado a un m nimo de 152 cm 5 pies de toda estructura con muros combustibles y o otras materias combustibles Mantenga un m nimo de 92 cm 3 pies alrededor de la carcasa del generador para facilitar la ventilaci n y el mantenimiento del generador En el estado de California es obligatorio seg n la ley el uso de apagachispas Secci n 4442 del C digo de Recursos P blicos de California Otros estados pueden tener leyes similares Las leyes federales se aplican en tierras federales Si equipa el silenciador con un apagachispas este deber ser mantenido en buenas condiciones de trabajo Conexion De Cargas Electricas e Deje que el motor se estabilice y se caliente por unos minutos despu s del arranque e Conecte y encienda las cargas el ctricas de 120 y o 240 Voltios AC monof sicas de 60 Hz que desse e NO conecte cargas de 240 Voltios a tomacorrientes de 120 Voltios e NO conecte cargas trifasicas al generador NO CONECTE cargas de 50 Hz al generador NO SOBRECARGUE EL GENERADOR Vea No Sobrecargue el Generador Parado Del Motor Desconecte todas las cargas el ctricas de los tomaco rrientes del panel del generador NUNCA de arranque o detenga el
52. sta garant a tiene efecto durante el per odo indicado y conforme a las condiciones estipuladas en la misma Para obtener servicio en garant a localice el distribuidor de servicio autorizado m s pr ximo llamando al 1 888 611 6708 Los distribuidores de servicio autorizado de Briggs amp Stratton Power Products son los nicos que pueden ofrecer servicio en garant a NO EXISTE OTRA GARANT A EXPRESA LAS GARANT AS IMPL CITAS INCLUYENDO AQUELLAS DE MERCANTIBILIDAD O CAPACIDAD PARA UN PROP SITO PARTICULAR EST N LIMITADAS AL PERIODO DE TIEMPO ESPECIFICADO O HASTA EL L MITE PERMITIDO POR LA LEY TODA Y CUALQUIER GARANT A IMPL CITA EST EXCLUIDA RESPONSABILIDAD POR DANOS CONSECUENTES BAJO CUALQUIER Y TODAS LAS GARANT AS EST N EXCLUIDAS HASTA EL L MITE DE EXCLUSI N PERMITIDO POR LA LEY Algunos pa ses o estados no admiten limitaciones en cuanto a la vigencia de una garant a impl cita y algunos no admiten la exclusi n o limitaci n de dafios resultantes o derivados Por lo tanto es posible que las limitaciones y exclusiones arriba mencionadas no se apliquen a su caso Esta garant a le otorga determinados derechos legales y es posible que usted cuente con otros derechos que pueden variar de un pa s a otro o de un estado a otro PERIODO DE GARANTIA Equipo Para Uso Del Consumidor Para Uso Comercial Tasador Presi n ae 994m Generador Port til 2 afios el segundo afio solamente para las
53. t Authorized service dealer by calling 1 888 61 6708 Warranty service may only be performed by a Briggs amp Stratton Power Products Authorized service dealer THERE IS NO OTHER EXPRESS WARRANTY IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE TIME PERIOD SPECIFIED OR TO THE EXTENT PERMITTED BY LAW ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED LIABILITY FOR CONSEQUENTIAL DAMAGES UNDER ANY AND ALL WARRANTIES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW Some countries or states do not allow limitations on how long an implied warranty lasts and some countries or states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation and exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from country to country or state to state WARRANTY PERIOD Portable Generator 2 Years 2nd year parts only The warranty period begins on the date of purchase by the first retail consumer or commercial end user and continues for the period of time stated in the table above Consumer use means personal residential household use by a retail consumer Commercial use means all other uses including use for commercial income producing or rental purposes Once equipment has been used commercially it shall thereafter be considered to be in commercial use for purpose
54. uientes instrucciones para encender Aseg rese de que la unidad est en una superficie plana IMPORTANTE Si la unidad no se arranca y utiliza en una superficie plana se pueden producir problemas de arranque y de parada durante el funcionamiento 2 Gire la v lvula del combustible a la posici n On Figura 13 Figura 13 V lvula de Combustible 3 Ponga en marcha el motor tal y como se explica en el manual del propietario del motor ADVERTENCIA El r pido repliegue del cable del arrancador retroceso impedira que el usuario suelte el cable a tiempo y tirara de su mano y brazo hacia el motor Como resultado podrian producirse fracturas contusiones o esguinces Cuando arranque el motor tire lentamente del cable hasta sentir una resistencia y a continuaci n tire r pidamente de l para evitar su retroceso NUNCA arranque o pare el motor cuando haya aparatos el ctricos conectados y en funcionamiento NOTA Si el motor arranca despu s de tirar tres veces del arrancador pero no sigue funcionando o si la unidad se para en funcionamiento aseg rese de que la unidad est en una superficie plana y compruebe que el nivel de aceite del cig efial es correcto Secci n 4 Operaci n La unidad puede equiparse con un dispositivo de protecci n de bajo nivel de aceite A ADVERTENCIA Los motores al funcionar producen calor La temperatura del silenciador y de las reas cercanas puede alcanzar o pa
55. un ambiente limpio y seco donde no ser expuesta al polvo suciedad humedad o vapores corrosivos Las ranuras del aire de enfriamiento del generador no deben estar tapadas con nieve hojas o cualquier otro material extrafios Revise frecuentemente la limpieza del generador y limpielo cuando est con polvo sucio con aceite humedad o cuando otras substancias extra as sean visibles en su superficie exterior NOTA NO recomendamos el uso de mangueras de jard n para limpiar el generador El agua podr a introducirse en el sistema de combustible del motor y causar problemas Adem s si el agua se introduce al generador a trav s de las ranuras para aire de enfriamiento algo del agua quedar retenida en los espacios vac os y grietas del aislamiento del devanado del estator y rotor La acumulaci n de agua y suciedad en los devanados internos del generador disminuir eventualmente la resistencia del aislamiento de estos devanados Para Limpiar el Generador Utilice un trapo h medo para limpiar las superficies exteriores PRECAUCION El tratamiento inadecuado del generador puede da arlo y acortar su vida productiva NO exponga al generador a una humedad excesiva polvo suciedad o vapores corrosivos NO inserte cualquier objeto a trav s de las ranuras de enfriamiento e Puede usar un cepillo de cerdas suaves para retirar la suciedad endurecida aceite etc Puede usar una m quina aspiradora para eliminar suc
56. voltaje calificado cuando funciona a una velocidad determinada NO modifique al generador en ninguna forma PRECAUCION El sobrepasar la capacidad del amperaje y vataje del generador puede dafiar al generador y los aparatos el ctricos conectados al mismo Vea No sobrecargue generador Encienda su generador y deje que el motor se estabilice antes de conectar las cargas el ctricas Conecte las cargas el ctricas en la posici n de apagado OFF luego encienda ON para su operaci n Apague OFF las cargas el ctricas y descon ctelas del generador antes de parar el generador PRECAUCION El tratamiento inadecuado del generador puede da arlo y acortar su vida productiva Use el generador solamente con la finalidad para el cual fue disefiado Si usted tiene alguna pregunta acerca de las finalidades de uso del generador preg ntele a su concesionario o llamada a 1 888 611 6708 Opere el generador solamente en superficies niveladas NO exponga al generador a una humedad excesiva polvo suciedad o vapores corrosivos NO inserte cualquier objeto a trav s de las ranuras de enfriamiento Si los aparatos conectados se sobrecalientan ap guelos y descon ctelos del generador Apague el generador si Se pierde la salida el ctrica El equipo produce chispas humo o emite llamas La unidad vibra de una manera excesiva Caracter sticas y Mandos CONOZCA SU GENERADOR LEA ESTE MANUAL DEL PROPIETARIO Y LAS REGLAS DE