1. Alarms 3 function audible alarm indicates power failure conditions 4 short beeps every 10 seconds overload continuous short beeps and low battery continuous tone Switches Yes includes 2 front panel mounted push button switches for system enable self test and alarm cancel functions SURGE NOISE SUPPRESSION AC surge 480 joules suppression AC suppression Instantaneous response time EMI RFI AC noise Yes suppression PHYSICAL Shipping weight Ibs 72 Shipping weight kg 32 7 Shipping 9 x 23 5 x 20 Dimensions HWD in Shipping 22 9 x 59 7 x 50 8 Dimensions HWD cm Unit weight Ibs Unit weight kg Unit Dimensions HWD in Unit Dimensions HWD cm Material of construction 64 29 1 3 5 x 17 5 x 19 8 89 x 44 5 x 48 3 Steel Form factors supported Cooling method Battery Access ENVIRONMENTAL Relative Humidity Storage Temperature Operating Temperature Line mode BTU hr Max COMMUNICATIONS Network monitoring port Software and cabling included SNMP compatibility WatchDog compatibility Rack 2U Built in cooling fan Battery access door allows hot swap battery replacement without powering connected equipment off 0 to 95 non condensing 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius 327 4 BTU hr Includes 4 built in monitoring ports 2 USB amp 2 DB9 Each supports on battery low ba
2. test and alarm cancel functions e Included UPSRMRII adjustable mounting rails support installation in 19 inch racks with a front to rear depth of 23 5 and 36 5 inches add a 2nd UPSRMRII accessory to extend the reach to 35 25 to 49 5 inches e UPS ships fully assembled in full compliance with DOT regulations no time consuming connection of internal batteries by user required e Supports 2 post rackmount and wallmount installation with optional 2POSTRMKITWM accessory e Supports upright tower placement with optional 2 9USTAND accessory e UL USA cUL Canada NOM Mexico FCC Class A Emissions listed e 2 year manufacturer s product warranty 250 000 Ultimate Lifetime Insurance Specifications SYSTEM OVERVIEW Voltage compatibility Frequency compatibility OUTPUT Output VA Output watts Output nominal voltage Output voltage regulation Output frequency regulation Outlet quantity type Customized load management receptacles Overload protection INPUT Maximum input amps Input connection type Input cord length Recommended Electrical Service BATTERY 120V AC 60 Hz 3000 2250 120V AC LINE MODE Sine wave line voltage 120V 18 8 LINE MODE Passes line frequency of 60Hz 10 4 NEMA 5 15R 4 NEMA 5 15 20R and 1 NEMA L5 30R 3 single outlet load banks with integraded switched PDU supports load shedding and remote reboot on demand of locked network devices Controllable via Power
3. Alert software to switch off optional loads like monitors to increase available runtime for servers and other critical devices Resettable circuit breaker 24A NEMA L5 30P includes user installable NEMA 5 20P replacement plug 10 ft 10 gauge 30A 120V Full load runtime Half load runtime Expandable battery runtime DC system voltage Typical battery lifespan Battery recharge rate Replacement Battery Cartridge 4 minutes 3000VA 11 minutes 1500VA Supports extended runtime with optional external battery packs BP48V242U limit 1 and BP48V60RT3U multi pack compatible 48V DC 3 6 years depending on usage 6 5 hours RBC94 2U VOLTAGE REGULATION Voltage regulation description Overvoltage correction Direct pass through Brownout correction Severe brownout correction Automatic Voltage Regulation AVR circuits maintain clean regulated computer grade 120V nominal output without using battery power during brownouts to 79V and overvoltages to 147V Input voltages between 128 and 147V AC are reduced by 12 Input voltages between 105 and 127V AC are passed on to connected equipment unchanged Input voltages between 95 and 104V AC are boosted by 12 Input voltages between 79 and 94V AC are boosted by 24 LEDS ALARMS amp SWITCHES Front panel LEDs 5 front panel LEDs 4 Green POWER LED Green VOLTAGE CORRECTION LED 3 color BATTERY CHARGE LED 3 color OUTPUT LOAD LED red BATTERY WARNING LED
4. Tripp Lite 1111 West 35th Street l Chicago IL 60609 USA POWER PROTECTION Telephone 773 869 1234 E mail saleshelp tripplite com Model SM3000RMNAFTA Smart Pro 2U Rack Tower Extended Run UPS NAFTA assembled version of SMART3000RM2U Highlights e 3000VA 120V 60Hz Sine Wave 2U Expandable Rack Tower UPS e Battery Independent Dual Boost AVR Corrects Brownouts to 79V and Overvoltages to 147V e Multiple interfaces 2 USB 2 DB9 and SNMPWEBCARD Slot e Integrated Switched PDU with Current Monitoring and 3 Controllable Load Banks e 9 Outlets 4 5 15R 4 5 15 20R 1 L5 30R NEMA L5 30P input 5 20P included e 250 000 Ultimate Lifetime Insurance USA Puerto Rico amp Canada only Description 3000VA line interactive UPS for server network and telecommunications equipment 2U rackmount form factor Corrects brownouts and overvoltages from 79 to 147 Sine wave output Uninterruptible Power Supply UPS maintains battery derived AC output during blackouts and severe voltage fluctuations Expandable runtime with optional external battery packs 9 output receptacles NEMA L5 30P input plug NEMA 5 20P replacement plug included Network grade AC surge and noise suppression Network management interfaces include 2 USB ports 2 DB9 serial ports and SNMPWEBCARD slot Supports simultaneous detailed monitoring of equipment load levels self test data and mains power conditions via all 5 network interfaces at once Includes PowerAlert monitoring
5. ages by 14 or 24 depending on the severity and reduces overvoltages by 12 e Network interfaces support simultaneous communications via 2 USB 2 DB9 serial and SNMUPWEBCARD slot e Included PowerAlert UPS monitoring software supports safe unattended shutdown monitoring and control via local connected servers plus any number of additional servers over IP e Communications ports support on battery low battery power restored AC voltage DC voltage output current monitoring battery charge current battery capacity internal UPS temperature AC line frequency timed inverter shutoff activate self test and load bank output power control e Built in Emergency Power Off EPO interface with cable e Sine wave output in AC and battery modes e Expandable runtime with optional battery packs a BP48V24 2U limit 1 and BP48V60RT 3U multi pack compatible e Half load runtime of 11 minutes 1125 watts e Full load runtime of 4 minutes 2250 watts e Includes 9 output receptacles arranged in 3 load banks 4 NEMA 5 15R 4 NEMA 5 15 20R 1 NEMA L5 30R e Ships with NEMA L5 30P input plug user installable NEMA 5 20P replacement plug included e Integrated 3 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual devices e 3 stage metered LEDs offer current monitoring and battery charge level e Mains power and voltage regulation LEDs offer at a glance power status information e Front panel switches support self
6. attery Pack Accessory optional CERTIFICATIONS Certifications WARRANTY Product Warranty Period Connected Equipment Coverage Optional Coverage Related Items Audio Cables CT120 BP48V24 2U limit 1 and BP48V60RT3U multi pack compatible Tested to UL1778 USA cUL Canada FCC Class A emissions NOM Mexico 2 year product warranty 250 000 connected equipment insurance USA Canada only 3 year 5 year next day and on site warranty coverage available for select opportunities contact Tripp Lite Instant Read AC Outlet Circuit Tester Qty optional Extended Warranties WEXT3 2200 3000 WEXT5 2200 3000 External Battery Packs BP48V24 2U BP48V60RT 3U Power Distribution PS7224 20 PDU1220 Rackmount Wallmount Kits 2POSTRMKITWM SNMP Accessories ENVIROSENSE SNMPWEBCARD Surge Protectors DTEL2 DNET1 DCATV Tower Stands 2 9USTAND USB Hubs Accessories U022 010 3 Year Extended Warranty For Smart Line Interactive and Online Tower or Rack models 2200 3000VA 5 Year Extended Warranty For Smart Line Interactive and Online Tower or Rack models 2200 3000VA or less BP48V242U External Battery Pack for UPS System BP48V60RT3U External Battery Packs for UPS System Tripp Lite Power Strip Multiple outlets wherever you need them Basic PDU Power Distribution Unit Safe reliable power distribution for critical networking equipment Universal 2 Post Rackmount Kit Support
7. s 2U to 4U UPS systems and battery packs Monitors temperature humidity and contact closure inputs Requires SNMPWEBCARD or switched PDU For remote monitoring and control via SNMP Web or telnet Network Surge Suppressor Essential protection for data and communication lines Network Surge Suppressor Essential protection for data and communication lines Network Surge Suppressor Essential protection for TV VCR coaxial lines Tower Stand Expandable Tower Base Stand UPS Accessory USB Cable 10 ft USB 2 0 AB Gold Device Cable More information including related products owner s manuals and additional technical specifications can be found online at www tripplite com en products model cfm txtModellD 3541 2009 Tripp Lite All Rights Reserved Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional
8. software and complete cabling Emergency Power Off EPO interface Integrated 3 bank switched PDU 3 stage metered current monitoring and battery charge LEDs Mains power and voltage regulation LEDs Audible alarm Self test 4 post rack mounting accessories 2 9USTAND and 2POSTRMKIT accessories available Field replaceable hot swappable internal batteries and battery packs Attractive all black UPS design Two year warranty with 250 000connected equipment insurance Extended warranty and service contracts available Applications e Ideal for protection of sensitive electronics in any application calling for upright tower or 19 inch rackmount UPS protection Common applications include any mix of servers workstations hubs routers concentrators IP telephony and traditional PBX switching systems Package Includes e SM3000RMNAFTA e PowerAlert Software and cabling e Mounting hardware for 4 post rackmount installation e Warranty information e Instruction manual Features e 3000VA 2250 watt output power capacity compatible with North American 120V 60Hz power e 2U rack tower UPS installs in standard 19 inch rack enclosures with an installed depth of only 18 inches e Protects sensitive networking equipment from blackouts voltage fluctuations and transient surges e Line interactive Automatic Voltage Regulation AVR corrects inputs from 79 147VAC back to usable 120V levels without consuming battery power e Dual boost AVR circuits boost undervolt
9. ttery power restored AC line voltage DC battery voltage load percentage battery charge current battery capacity internal UPS temperature and line frequency status Includes PowerAlert UPS monitoring software for all common network and standalone operating systems Ships with 4 cables 2 USB amp 2 DB9 Built in accessory slot accommodates internal SNMP Web card and other network accessories Yes compatible with Tripp Lite s Watchdog system service to restore operation to locked equipment through soft reboot of applications OS or hard power off on reboot of connected equipment ideal for unattended kiosk applications LINE BATTERY TRANSFER Transfer time from line power to battery mode Low voltage transfer to battery power High voltage transfer to battery power SPECIAL FEATURES EPO port TVSS grounding Cold Start Appearance 2 4 milliseconds 79V resets to line power as voltage increases to 83V 147V resets to line power as voltage decreases to 144V Includes RJ11 EPO emergency power off port and interconnection cable Includes back panel grounding point with thumbscrew for data line surge suppressors and other network accessories requiring a safe grounding point Yes inverter can be cold started to enable temporary AC output during a power failure Attractive gray rackmount housing optional use 2U black front bezel included to enable black color appearance BATTERY PACK ACCESSORY optional B