Home
Tripp Lite RV Series User's Manual
Contents
1. Front View Dual Input Output Hardwire Models Rear View Single Input Output Hardwire Models Switch Modes After configuring mounting and connecting your Inverter Charger you are able to operate it by switching between the following oper ating modes as appropriate to your situation AUTO REMOTE Switch to this mode when you need constant uninterrupted AC power for connected appliances and equipment The Inverter Charger will continue to supply AC power to connected equipment and to charge your connected batteries while utility or generator supplied AC power is present Since the inverter is ON but in Standby in this mode it will automatically switch to your battery system to supply AC power to connected equipment in the absence of a utility generator source or in over under voltage situations AUTO REMOTE also enables an optional remote control module Tripp Lite model APSRM4 sold separately or included with select models to function when con nected to the unit CHARGE ONLY Switch to this mode when you are not using connected appliances and equipment in order to conserve battery power by disabling the inverter The Inverter Charger will continue to sup ply AC power to connected equipment and charge connected batteries while utility or generator supplied AC power is present However since the inverter is OFF in this mode it WILL NOT supply AC power to connected equipm
2. TRIPP LITE 12 Volt Inverter Charger TRIPP LITE 12 Volt Inverter Charger Alternateur 12 volts Mise la terre du v hicule Batterie principale 12 volts Batterie auxiliaire stationnaire 12 volts Fusible amp bloc fusibles UL mont moins de 457 mm 18 po de la batterie 6 Isolateur de batterte W C blage de gros diam tre calibre maximal 2 0 Gauge pour s adapter aux bornes Fil de mise la terre calibre 8 AWG minimum REMARQUE Les mod lesSelect poss dent deux terminaux positifs et deux terminaux n gatifs CC l aide de la m me architecture de connexion illustr e sur les sch mas relier les deux bornes n ga tives du chargeur onduleur l unique borne n gative de la batterie avec deux c bles de calibre 2 0 relier les deux bornes positives du chargeur onduleur l unique borne positive de la batterie avec deux c bles de calibre 2 0 par l interm diaire de deux fusibles ou bloc fusibles UL ou quivalent Utiliser l quivalent de deux c bles 2 0 pour toutes les autres connexions dans le syst me de batterie Connexion aux deux bornes CC Il est acceptable d utiliser deux c bles pour connecter votre batterie un seul terminal CC positif et un seul terminal CC n gatif cependant votre chargeur ond uleur fournira une alimentation de sortie r duite Le choix de la borne positive ou n gative pour la connexion ne fait aucune diff rence car les deux bornes positives sont li es la masse int rieure ment c
3. part REMARQUE Pour les chargeurs onduleurs de Tripp Lite fournissant 1 000 watts ou moins d alimentation CA continue une batterie grande capacit sera normallement suffisamment puissante pour alimenter plusieurs applications avant qu une recharge soit n cessaire Pour les applications mobiles si une seule batterie est con tinuellement recharg e par un alternateur ralenti lev ou plus rapide alors il ne sera peut tre pas n cessaire de la recharger depuis le secteur ou d une g n ratrice Pour les chargeurs onduleurs de Tripp Lite de plus de 1 000 watts utilis s dans les applications mobiles Tripp Lite recommande que vous utilisiez au moins deux batter ies recharg es si possible par un alternateur robuste chaque fois que le v hicule est en marche Les chargeurs onduleurs de Tripp Lite vous fourniront une alimentation ad quate pour un usage ordinaire dans des dur es lim it es sans le support d une alimentation de secteur ou de g n ratrice Cependant lors du fonctionnement de charges lectriques extr mement lourdes leur puissance maximale vous pourriez avoir envie d assister vos batteries en faisant tourner une g n ratrice auxiliaire ou un moteur de v hicule et le faire une vitesse plus rapide que le ralenti EJ MISE EN GARDE Monter votre chargeur onduleur AVANT la connexion de la bat terie CC et l alimentation CA Ne pas suivre ces directives pourrait entra ner des blessures et ou des donnages
4. OPTIONAL Setting Procedure Move to Equalize DOWN position for three seconds This DIP Switch is momentarily engaged Reset e Move to Reset UP position and leave it there This is the to begin the process of equalizing the factory default setting char ge state of your battery s cells by time i CAUTION Do not leave DIP switch B3 in the down position after beginning process Battery limited overcharge of all cells This can charge equalization should only be performed in strict accordance with the battery manufacturer extend the useful life of certain types of tN ie era batteries consult with your battery s manufacturer to determine if Battery Charge Switch Position your batteries could benefit from this process The charge equaliza Reset Un fact ti tion process is automatic once started it can only be stopped by ese p factory se ing removing the input power Equalize Down momentarily Set Battery Charging Amps OPTIONAL Battery Charger Switch Position Check specifications for your unit s high and low charging amp Low Charge Amps Up options By setting om high charging High Charge Amps Down factory setting your batteries will charge at maximum e ile aaa speed and your RV 12V DC system loads will be well supplied When set ting on low charging you lengthen the life of your batteries especially small er ones CAUTION When switching to the High Charge Amp setting the user mu
5. Si le probl me persiste ne pas communiquer avec le vendeur ou lui renvoyer le chargeur onduleur A la place appeler Tripp Lite au 773 869 1233 Un technicien des r parations vous demandera le num ro de mod le du chargeur onduleur son num ro de s rie et sa date et essaiera de r gler le probl me au t l phone 3 Si le probl me n cessite une r paration le technicien vous mettra un num ro d autorisation de retour de mat riel RMA exig e pour une r paration Emballer soigneusement le chargeur onduleur pour viter des dom mages pendant l exp dition Ne pas utiliser de billes de styrofoam pour emballer Tout dommage direct indirect sp cial accidentel ou fortuit arriv au chargeur onduleur pendant le transport Tripp Lite ou un centre de service autoris Tripp Lite est exclu de la garantie Les frais de transport des chargeurs onduleurs envoy s Trip Lite ou un centre de service autoris Tripp Lite doivent tre pr pay s Inscrire le num ro de RMA sur le paquet Si le chargeur onduleur est encore sous garantie joindre une copie de votre facture Renvoyer le chargeur onduleur pour r paration par un transporteur assur l adresse que vous a donn le technicien de service de Tripp Lite C est la cause la plus courante des demandes de service laquelle on peut rem dier facilement en suivant les directives de remise en marche dans ce manuel Si vous avez besoin d un emballage le technicien peut vous faire
6. e de fonctionnement pourrait tre consid rablement r duite Si vous utilisez le m me groupe de batteries pour alimenter le chargeur onduleur ainsi que les charges CC votre groupe de batteries devra tre calibr ad quatement des charges plus lour des exigeront un groupe de batteries avec un plus grande capacit A h ou la dur e de fonctionnement des batteries pourrait tre consid rablement r duite Les batteries celulles liquides ventil es ou cellules en gel AGM scell es sont id ales Les batteries 6 volts de voiturette de golf marine d charge pouss e ou d charge pouss e 8D sont aussi acceptables Vous devez r gler le commutateur DIP de type de batterie du chargeur onduleur voir la section Configuration pour plus de renseignements pour l apparier aux types de batteries que vous connectez ou vos batteries pourraient se d grader ou tre endom mag es sur une longue p riode Dans beaucoup de cas la batterie du v hicule sera la seule install e Les batteries auxiliaires doivent tre identiques aux bat teries du v hicule si elles sont connect es ensemble Correspondance de la capacit A h de la batterie votre application Choisir une batterie ou un syst me de batteries qui fournira votre chargeur onduleur un voltage CC appropri et une capacit A h suff isante pour alimenter votre application M me si les chargeurs onduleurs sont hautement efficaces pour la conversion du CC au CA leur capacit nomi
7. is set to AUTO REMOTE this light will ILLUMI NATE CONTINUOUSLY when your connected equipment is receiving continuous AC power sup plied from a utility generator source If the operating mode switch is set to CHARGE ONLY this light will BLINK to alert you that the unit s inverter is OFF and will NOT supply AC power in the absence of a utility generator source or in over under voltage situations INV Inverting Yellow LED This light will ILLUMINATE CONTINUOUSLY whenever con nected equipment is receiving battery supplied inverted AC power in the absence of a utility gener ator source or in over under voltage situations This light will be off when AC power is supplying the load This light will BLINK to alert you if the load is less than the Battery Charge Conserver Load Sense setting LOAD Red LED This red light will ILLUMI foperarion LINE w On NATE CONTINUOUSLY whenever the inverter is functioning and the power demanded by connected appliances and equipment exceeds 100 of load mt capacity The light will BLINK to alert you when the inverter shuts down due to a severe overload or overheating If this happens turn the operating mode switch OFF remove the over load and let the unit cool You may then turn the operating mode switch to either AUTO REMOTE or CHARGE ONLY after it has adequately cooled This light
8. match the type of batteries you connect or your batteries may be degraded or damaged over an extended period of time See Battery Selection p 9 for more information 135V Wet Cell Battery Type Switch Position Voltage Switch Position Gel Cell Sealed Battery Up 145V Up Wet Cell Vented Battery Down factory setting 135V Down factory setting Charger Inhibit Most models Function Switch Position Charger Inhibited Up Charger Enabled Down factory setting Most of your connected appliances and equipment will perform adequately when your Inverter Charger s High AC Input Voltage Point DIP Switch 2 of Group is set to 135V and its Low AC Voltage Input Point DIP Switches 3 and 4 of Group A are set to 95V However if the unit frequently switches to battery power due to momentary high low line voltage swings that would have little effect on equipment operation you may wish to adjust these set tings By increasing the High AC Voltage Point and or decreasing the Low AC Voltage Point you will reduce the number of times your unit switches to battery due to voltage swings Configuration continued All Models Select Low AC Input Voltage Point for Switching to Battery OPTIONAL 105V Switch Voltage Position 105V A4 Up amp A3 Up 95V A4 Up amp A3 Down 85V A4 Down amp A3 Up 75V A4 Down amp A3 Down factory setting Most of your connecte
9. pas de sortie pleine charge Limitati B2 en haut amp te aray Ta Fes ae B4 Pas de limitation B2 amp B1 en Bas Aucune limitation du chargeur aucune limite de charge Ba il fl B4 commence losrque la charge du chargeur onduleur atteint 33 du r gime nominal du chargeur onduleur La sortie du chargeur passe graduellement de la sortie pleine 33 du r gime nominal du chargeur onduleur environ 40 de la sortie pleine pleine charge La plupart des mod les sont pr r gl s en usine la Limite la plus haute RV20120EM est pr r gl la Limite la plus basse RV2012UL et RV30120EM mod les peuvent seulement tre r gl s ala Limite la plus haute ou Limite la plus basse Le commutateur B2 n est pas op rationnel Configuration suite Choix de l galisation de la charge de la batterie Proc dure de r glage OPTIONNEL e Aller la position galiser EN BAS pendant trois secondes Ce commutateur DIP est engag momen e Aller la position R amorcer EN HAUT et restez l C est tan ment pour commencer le processus I Reamorcor un r glage d usine par d faut d galisation de l tat de char ge des cel ATTENTION Ne pas laisser le commutateur DIP B3 dans la position basse apr s le d but du lules de votre batterie par une surcharge os processus L galisation de la charge de la batterie doit tre effectu e en stricte concordance
10. 200 A deux 175 A deux 175A deux 275 A UL requis Courant d entr e CC la tension nominale CC en pleine charge 73 A 117 A 190A 185A 282 A CHARGEUR DE BATTERIE Sp cifications courantes pour tous les mod les Acceptation de tension CC Liquide Gel 14 4 V 14 2 V Tension flottante CC liq gel 13 3 V 13 6 V Tension d entr e nominale 120 V CA Capacit de charge CC 45 A 11A 55 A 14A 100 A 25 A 100 A 25A 140 A 35A Courant d entr e CA 8 2 A 11A 20A 21A 25A FONCTIONNEMENT DE LA LIGNE CA Sp cifications courantes pour tous les mod les Fr quence d entr e nominale 60 Hz 10 Tension d entr e maximale transfert la batterie 145 V CA Except les mod les OEM 145V 135V s lectionnable Tension minimale d entr e S lectionnable 75 85 95 ou 105 VCA S lectionnable 75 85 95 ou 105 VCA S lectionnable 75 85 95 ou 105 VCA S lectionnable 75 85 95 ou 105 VCA S lectionnable 75 85 95 ou 105 V CA Transfert la batterie Courant maximal d entr e 30 A 33 A 38 A 43 A 30 A Continu chargeur au maximum Courant maximal CA de d rivation 20 A 20 A 30 A 20 20 A 20 20 A Dur e OverPower jusqu 1 heure Dur e DoubleBoost jusqu 10 secondes La dur e r elle d pend de l ge de la batterie de son niveau de charge et de la temp rature ambiente R glage d usine Tripp Lite a une politique d am lioration continue Les sp ci
11. A 11A 20A 21A 25A LINE VAC OPERATION Common Specifications for All Models Input Frequency Nominal 60 Hz 10 Maximum Input Volts Transfer to Battery 145 VAC Except OEM Models Selectable 145V 135V Minimum Input Volts Selectable 75 85 95 or 105 VAC Selectable 75 85 95 or 105 VAC Selectable 75 85 95 or 105 VAC Selectable 75 85 95 or 105 VAC Selectable 75 85 95 or 105 VAC Transfer to Battery Maximum Input AC Current 30 A 33 A 38 A 43 A 30 A Continuous Charger at Maximum Maximum Bypass AC Current 20 A 20 A 30 A 20 20 A 20 20 A OverPower duration up to 1 hour DoubleBoost duration up to 10 seconds Actual duration depends on battery age battery charge level and ambient temperature Factory setting The policy of Tripp Lite is one of continuous improvement Specifications are subject to change without notice Minimum Recommended DC Cable Sizing Chart Note on Labeling Two symbols are used on the RV labels Use in conjunction with DC wiring connection instructions in the Battery Connection section V AC Voltage V DC Voltage Inverter Charger DC Volt 12 Wire Gauge vs Maximum Distance from Unit to Battery Twin 00 2 0 00 2 0 RV20120EM amp RV30120EM only RIPP i O 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com N R Not Recommended NOTE Acceptable power is directly related t
12. Mounting should be in the driest location available Leave a minimum of 2 clearance at front and back of the Inverter Charger for proper ventilation To avoid automatic Inverter Charger shutdown due to overtemperature any compartment that contains the Inverter Charger must be properly ventilated with adequate outside air flow The heavier the load of connected equipment the more heat will be generated by the unit Do not install the Inverter Charger directly near magnetic storage media as this may result in data corruption Do not install near flammable materials fuel or chemicals Battery Connection Warnings The Inverter Charger will not operate with or without utility power until batteries are connected e Multiple battery systems must be comprised of batteries of identical voltage age amp hour capacity and type e Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated your batteries should not be installed whether for a mobile or stationary application in a dead air compartment Ideally any compartment would have some ventilation to outside air Sparks may result during final battery connection Always observe proper polarity as batteries are connected Do not allow objects to contact the two DC input terminals Do not short or bridge these terminals together Serious personal injury or property damage could result Equipment Connection Warnings Do not use a Tripp Lite RV
13. OPTIONNEL tous les mod les Tous les mod les sont quip s d une prise sytle t l phone 8 conducteurs pour utilisation l aide d un module module optionnel de com mande distance mod le Tripp Lite APSRM4 vendu s par ment ou inclus avec les mod les Select Le module distance permet au chargeur onduleur d tre mont dans un compartiment ou une armoire hors de vue tout en fonctionnant commod ment depuis une zone d activit ou partir du panneau de contr le de votre VR Voir les directives jointes au module de commande distance Connexion de c ble de detection de temp rature de batterie pas sur le mod le 750 La fonction de d tection de temp rature de batterie prolonge la dur e de la batterie en r glant le niveau de tension flottante de charge en fonction de la temp rature de la batterie Connecter le c ble du capteur le c ble y compris sur les mod les Select a un connecteur de style RJ une extr mit et un capteur noir l autre au jack de style RJ situ sur le c t du chargeur onduleur et identifi Remote Temp Sense D tection de temp rature distance A l aide de ruban adh sif lectrique ou en toile fourni par l utilisateur fixer le capteur sur le c t de la bat terie sous le niveau de l lectrolyte Assurez vous qu il n y a rien m me pas du ruban entre le capteur et le c t de la batterie Pour emp cher de fausses lectures dues la temp rature ambiante placer le capteu
14. Series Number AGAP5088 AGAP5094 AP5626 AGAP200012MVP3 AGAP4669 AC Input Connection Hardwire Hardwire Hardwire Hardwire Hardwire INVERTER Common Specifications for All Models DC Input Volts Nominal 12 VDC DC Input Voltage Range 10 15 VDC Output Volts Nominal 120 VAC 5 Output Frequency Nominal 60 Hz 0 5 Efficiency 88 to 94 depending on load and temperature Tripp Lite Inverter Chargers include a Battery Charge Conserver Load Sense Control which saves battery power by allowing users to set the minimum load level at which the unit s inverter turns on Users can significantly reduce the No Load DC Input Current approximately 1 to 3 A for all models to a very low amp level with the use of this control Continuous Power 20 C 750 1250 2000 2000 3000 OverPower Peak Surge Power 1125 1875 3000 3000 4500 DoubleBoost Peak Surge Power 1500 2500 4000 4000 6000 Maximum Output AC Current 6 3 A 10 4 A 16 7 A 16 7 A 25 A Continuous UL Recognized DC Fuse 125 A 200 A two 175 A two 175A two 275 A Required DC Input Current Nominal V DC Full Load 73 117 A 190 A 185A 282 A BATTERY CHARGER Common Specifications for All Models Acceptance Volts VDC Wet Gel 14 4 V 14 2 V Float Volts DC w gel 13 3 V 13 6 V Input Volts Nominal 120 VAC Charging Capacity DC 45 A 11A 55 A 14A 100 A 25A 100 A 25A 140 A 35 A Input Current AC 8 2
15. au chargeur onduleur et aux syst mes connect s Tripp Lite fabrique une vari t de diff rents chargeurs onduleurs avec de nombreuses et diff rentes options de montage pour les applications sur des v hicules et autres Tripp Lite recommande un montage permanent de votre chargeur onduleur selon l une des configurations illustr es ci dessous L utilisateur doit fournir la quincaillerie de fixation et doit d terminer si la quincaillerie et la surface de fixation peuvent supporter le poids du chargeur onduleur Communiquez avec Tripp Lite si vous avez besoin d aide pour le montage de votre chargeur onduleur Mod les 750 et 1250 Seulement Qu il soit mont horizontalement ou verticalement l Inverseur doit tre situ dans un compartiment clos prot g des conditions m t orologiques EMA l aide des mesures du sch ma installer deux attaches de 6 mm 1 4po fourni par l utilisateur dans une surface horizontale rigide en laissant les t tes d passer l g rement J Glisser le chargeur ond uleur entre les attaches pour engager les fentes de fixation moul es en bas du bo tier du chargeur onduleur Installer et deux attach es de 6 mm 1 4po fourni par l utilisateur dans les pieds de fixation moul s en avant du boitier du chargeur onduleur Le cabinet de polycarbone et le pied de support de votre circuit inverseur chargeur sont suffisamment robustes pour vous permettre un montage vertical si le compartiment de votre v hicule re
16. des sorties double source avec alimention CA de la sortie 2 disponible seulement en mode de conversion Connecter comme suit le fil et le tube protecteur fournis par l utilisateur aux connexions Entr e Connecter les fils entrants aux fils vivant noir pour Entr e 1 CA noir pour Entr e 2 CA neutre blanc pour Entr e 1 CA blanc pour Entr e 2 CA et de mise la terre vert jaune Sortie Connecter les fils sortants aux fils vivant noir pour Sortie 1 CA noir pour Sortie 2 CA neutre blanc pour Sortie 1 CA blanc pour Sortie 2 CA et de mise la terre vert jaune ACINT ACIN2 ACOUTI ACOUT2 amp Entr e 2 CA Sortie 2 CA Entr e 1 CA Sortie 1 CA Connexion d Entr e Sortie CA suite Source double Entr e Sortie Source simple Entr e sortie L entr e 1 CA fournira seulement l alimentation de secteur la L alimentation convertie par batterie est fournie la fois la sortie 1 CA sortie 1 CA et la sortie 2 CA e Si vous avez une seule source d entr e CA 120 V vous devez la e Si vous avez un seul circuit de sortie vous devez le connecter connecter l entr e 1 CA la sortie 1 CA L entr e 2 CA fournira seulement l alimentation de secteur la sortie 2 CA Connexions Entr e Sortie source simple ou source double En plus d alimenter le
17. earth ground See the Feature Identification section to locate the Main Ground Lug on your specific Inverter Charger model All installations must comply with national and local codes and ordinances e Connect Fuse NEC National Electrical Code article 551 requires that you connect all of your Inverter Charger s positive DC Terminals directly to a UL listed fuse s and fuse block s within 18 inches of the battery The fuse s rating must equal or exceed the Minimum DC Fuse Rating listed in your Inverter Charger s specifications See Specifications for fuse and fuse block rec ommendations See diagrams below for proper fuse placement WARNING Failure to properly ground your Inverter Charger to a vehicle s chassis or earth ground may result in a lethal electrical shock hazard e Never attempt to operate your Inverter Charger by connecting it directly to output from an alternator rather than a battery or battery bank e Observe proper polarity with all DC connections Vehicular Your Inverter Charger s Nominal DC Input Voltage must match the voltage of your battery or batteries 12 Volts in most vehicular applications It is possible to connect your Inverter Charger to the main battery within your vehicle s electrical system In most vehicles the Inverter Charger will be connected to one or more dedicated auxiliary house batteries which are isolated from the drive system to prevent possible draining of the main bat
18. envoyer un emballage appropri Votre chargeur onduleur ne requiert aucun entretien et ne contient aucune pi ce r parable ou rempla able par l utilisateur mais il doit tre maintenu au sec en tous temps V rifier p riodiquement nettoyer et reserrer toutes les connexions de c ble si n cessaire la fois de l u nit et de la batterie D pannage Essayez ces solutions aux probl mes courants du chargeur onduleur avant d appeler pour une assistance Communiquez avec le service la client le de Tripp Lite au 773 869 1234 avant de renvoyer votre unit pour r paration SYMPT ME Pas de sortie CA Les trois voyants indicateurs sont teints La batterie ne se recharge pas Entr e CA pr sente PROBL MES L unit n est pas correctement branch sur le secteur CORRECTIONS Brancher l unit sur le secteur Le commutateur de mode de fonctionnement est OFF et l entr e CA est pr sente Mettre le commutateur de mode de fonctionnement sur AUTO REMOTE ou CHARGE ONLY C est normal lorsque le commutateur de mode de fonctionnement est sur CHARGE ONLY et qu il n y a pas entr e CA Aucune correction requise La sortie CA reviendra quand l entr e CA reviendra Mettre le commutateur de mode de fonctionnement sur AUTO REMOTE si vous avez besoin de sortie CA Le disjoncteur du circuit a saut R armer le disjoncteur L unit s est teinte cause d une sur
19. galiser avec les directives et les sp cifications du fabricant de batterie temporaire de toutes les cellules Cela per met de prolonger la vie de certains types de batteries consulter votre fabricant de batterie pour savoir si vos batteries peuvent b n ficier de ce processus Le processus d galisation de la charge est automatique un fois commenc il peut seulement tre arr t en Egaliser En bas momentan ment enlevant l alimentation d entr e Charge de la batterie Position du commutateur R amorcer En haut r glage d usine R glage de l intensit de charge de batterie OPTIONNEL Chargeur de batterie Position du commutateur V rifier les sp cifications des options d intensit de charge sup rieure et Intensit inf rieure de charge Haut inf rieure de votre unit En r glant la charge sup rieure vos batteries Intensit sup rieure de charge Bas r glage d usine chargeront la vitesse maximale et les charges de votre syst me RV 12V DC seront Tage p 2 ATTENTION En passant sur l intensit sup rieure de charge l utilisateur doit s assurer que bien aliment es En r glant la charge la capacit amp res heure du syst me de batterie exc de l amp rage du r glage d intensit inf rieure vous rallongez la dur e de vos bat sup rieure de charge ou les batteries pourraient s endommager ou se d grader gt teries Intensit sup rieure de charge R g
20. imiser leur utilisation Commutateurs de configuration bo tier DIP Optimise le fonctionnement du chargeur onduleur selon votre application Voir la section configuration pour les directives de r glage Commutateur Mode de fonctionnement Commande le fonc tionnement du chargeur onduleur Le r glage AUTO REMOTE assure que votre quipement re oit une alimentation constante et ininterrompue de courant continu Il permet aussi de surveiller et de commander le chargeur onduleur distance l aide d un module optionnel de commande distance mod le Tripp Lite APSRM4 vendu s par ment ou inclus avec les mod les Select Avec le r glage CHARGE ONLY vos batteries reviennent en pleine charge plus rapidement en fermant le con vertisseur ce qui arr te le d chargement des batteries Voir la sec tion Fonctionnement pour les directives de r glage DEL LINE INVERT LOAD Les voyants intu itifs feux de circulation signalent si le chargeur onduleur fonctionne a partir d une ligne CA ou d une batterie CC Ils vous avertissent galement quand la charge de votre quipement est trop lev e Voir la section Fonctionnement pour les directives sur la lecture des lampes t moin DEL de TENSION DE BATTERIE BATT VOLTAGE Ces trois indicateurs s allumeront en plusieurs s quences pour indiquer le niveau approximatif de la batterie Ei Bornes d alimentation CC Connectez vos bornes de b
21. nominal du fusible doit tre gal ou sup rieur au calibre mini mal de fusible CC inscrit dans les sp cifica tions de votre CC Voir les sp cifications pour les recommandations de fusible et de bloc fusibles Voir les sch mas ci dessous pour l emplacement correct des fusibles MISE EN GARDE o Ne pas mettre votre chargeur onduleur la masse au ch ssis du v hicule ou a la terre peut entra ner un risque de choc lectrique mortel e Ne jamais essayer de faire fonctionner votre chargeur onduleur en le connectant directement la sortie d un alternateur plut t qu une batterie ou un groupe de batterie e Observez la bonne polarit avec toutes les connexions CC V hiculaire La tension nominale d entr e CC de votre chargeur onduleur doit corespondre la tension de votre ou de vos batteries 12 volts dans la plupart des application v hiculaires Il est possible de connecter votre chargeur onduleur la batterie principale dans le syst me lectrique de votre v hicule Dans la plupart des v hicules le chargeur onduleur sera connect l une ou plusieurs des batteries auxiliaires stationnaires d di es qui sont isol es du syst me de propulsion pour emp cher l puisement possible de la batterie principale 12 Volts Connexion 12 volts de la batterie principale 12 Volts 12Volts Connexion en parall le isol e des batteries principale et auxiliaire 12 volt
22. ou des hausses de la tension votre circuit inverseur chargeur commute automatiquement et imm diatement pour invertir la sortie de la pile l quipement c a connect Meilleur pour votre quipement Niveaux de protection de qualit sup rieure Protection ISOBAR int gr e contre les surtensions Protection automatique de surcharge Sortie id ale pour toutes les charges Sortie fr quence contr l e e Commutation automatique de charge e Partage quilibr des charges Meilleur pour votre batterie Recharge plus rapide de batterie e Amp rage lev Chargeur de batterie 3 tages r glable Protection efficace de la batterie Conservateur de charge de batterie D tecteur de charge D tection de temp rature de batterie Inversion hautement efficace de CC CA Meilleur pour vous Fonctionnement silencieux simple et sans entretien e Lumi res et commutateurs multi fonctions e D marrage automatique de la g n ratrice e Fabrication r sistant l humidit Table des mati res Garantie 15 Montage 23 S curit 16 Connexion de la batterie 24 Identification des caract ristiques 17 Connexion d entr e sortie CA 25 26 Fonctionnement 18 19 Service Entretien 26 Configuration 19 21 D pannage 27 Choix de batterie 22 English 1 Disponible sur tous les mod les sauf les mod les 750 Les chargeurs onduleurs r sistent l humidit mais ne sont pas tanches Copyright 2006 Tous
23. pas la limitation ou l exclusion de garanties implicites en cons quence les limitations ou exclusions ci dessus pourraient ne pas s appliquer l a cheteur A L EXCEPTION DE CE QUI EST CONTENU CI DESSUS EN AUCUN CAS TRIPP LITE NE SERA TENU RESPONSABLES DE DOMMAGES DIRECTS INDIRECTS SP CIAUX ACCESSOIRES OU CONSECUTIFS ISSUS DE L USAGE DE CE PRODUIT MEME EN CAS D AVIS DE LA POSSIBILIT D UN TEL DOMMAGE En particulier Tripp Lite n est pas responsable des co ts tels que les pertes de profits ou de recettes la perte d quipement la perte de l usage d quipement la perte de logiciels la perte de donn es les co ts de remplacement les r clamations par des tiers ou autre Num ros d identification de conformit aux r glements des fins de certification et d identification de conformit aux r glements votre produit Tripp Lite a re u un num ro de s rie unique Ce num ro se retrouve sur la plaque signal tique du produit avec les inscriptions et informations d approbation requises Lors d une demande d information de conformit pour ce produit utilisez toujours le num ro de s rie I ne doit pas tre confondu avec le nom de la marque ou le num ro de mod le du produit Tripp Lite a une politique d am lioration continue Les sp cifications sont sujettes changement sans pr avis Remarque sur l tiquetage Deux symboles sont utilis s sur les tiquettes de VR V voltage CA Via voltage CC Importante
24. t complet de l alimentation du secteur Pour r duire la possibilit de d clenchement de ce disjoncteur tous les chargeurs onduleurs peuvent tre r gl s pour limiter automatique ment la sortie du chargeur La somme de la charge CA de l unit et de l alimentation de charge reste inf rieure la charge nominale du dis joncteur Si n cessaire la fonction de limitation du chargeur poss de quatre r glages vous permettant de r duire la consommation du charge de plus en plus si le disjoncteur d entr e CA continue de se d clencher sous des charges CA normales d appareils branch s en aval de l u nit Les figures montrent comment r gler vos commutateurs DIP pour la limitation du chargeur Tous les mod les Tous les mod les l exception de Choix des points de limitation du chargeur de batterie RV2012UL amp RV30120EM OPTIONNEL Limitation minimale B2 en bas amp Limitation majeure B2 amp BI en haut La limitation du chargeur prend i i commence lorsque la charge du chargeur B1 en haut La limitation du chargeur onduleur atteint 66 du r gime nominal l f du chargeur onduleur La sortie du chargeur passe graduellement de la sortie pleine 66 du r gime nominale du chargeur onduleur environ 40 de la sortie pleine pleine charge effet au moment o une charge de 120 V CA est appliqu e la sortie du chargeur passe graduellement de sortie pleine sans charge de 120 V
25. will be off when AC power is sup plying the load BATT VOLTAGE LEDs If the operating mode switch is in the AUTO REMOTE or Charge Only position the LEDs indicate the approximate charge level and voltage of your connected battery bank and alert you to several fault conditions See Chart for charge and voltage levels LED Function with Switch in AUTO REMOTE or CHARGE ONLY Position Approximate Battery Charge Level LEDs Battery Capacity Illuminated Charging Discharging Green 91 Full Green amp Yellow 81 90 Yellow 61 80 Yellow amp Red 41 60 Red 21 40 All three lights off 1 20 Flashing red 0 Inverter shutdown Charge levels listed are approximate Actual conditions vary depending on battery condition and load Inverter shutdown protects battery against damage due to excessive discharge Fault Condition LEDs Fault Illuminated Condition All three lights Excessive discharge flash slowly Inverter shutdown 3 a All three lights Overcharge Charger flash quickly shutdown 7 Approximately second on second off See Troubleshooting section Inverter shutdown protects battery against damage due to excessive discharge Approximately 1 4 second on 14 second off Charger shutdown protects battery against damage due to over
26. 61 80 41 60 21 40 1 20 0 Onduleur a l arr t Verte et jaune Jaune Jaune et rouge Rouge Les trois lumi res teintes EHR Rouge clignotant Les niveaux de charge sont approximatifs Les conditions r elles varient selon l tat et la charge de la batterie L arr t de l onduleur prot ge la batterie contre les dommages dus une d charge excessive tat de d faut DEL allum es tat de d faut D charge excessive Onduleur arr t E Les trois lumi res Surcharge clignotent rapidement chargeur arr t Les trois lumi res clignotent lentement see Approximativement 1 2 seconde allum es 1 2 seconde teintes Voir section D pannage L arr t de l onduleur prot ge la batterie contre les dommages dus une d charge excessive Approximativement 1 4 seconde allum es 1 4 seconde teintes L arr t du chargeur prot ge la batterie contre les dommages dus une surcharge Peut aussi indiquer un d faut de chargeur de batterie Voir section D pannage Fonctionnement sie Position pour r armer votre chargeur onduleur pour restaurer l alimentation CA Votre chargeur onduleur peut cesser de fournir une alimentation CA ou une alimentation de charge CC de fa on se prot ger contre une surcharge ou pour prot ger votre syst me lectrique Pour restaurer un fonctionnement normal R armemen
27. Except 750 amp 1250 Models Note When operating an RV2012UL marine model in a marine application refer to the accompanying marine owners manual addendum Whether mounted horizontally or vertically the Inverter must be located in an enclosed compartment shielded from outside weather conditions Using the measurements from the diagram install two user sup plied 1 4 6 mm fasteners into a rigid horizontal surface leaving the heads slightly raised BJ Slide the Inverter Charger forward over the fasteners to engage the mounting feet molded on the front of the Inverter Charger cabinet Install and tighten additional user supplied 1 4 6 mm fasteners into the mounting feet molded on the rear and sides of the Inverter Charger cabinet The rear feet extend beyond the unit s cabinet to provide for adequate ventilation space behind the cooling fan s they should not be removed The polycarbonate cabinet and mounting feet of your Inverter Charger are durable enough to allow for vertical mount ing as well if your vehicle compartment requires this configura tion For vertical mounting the control panel of the Inverter Charger should face up Allow 2 minimum front and rear clearance for adequate ventilation 9 59 in a Ben 5 87 in 59 in 9 59 in 1491cm B 57 in Sh ae uem amp 2 14 91 cm NE 1 6 aise Note RV model cabinets may have different front panel features but all mount as per the figure abo
28. Inverter Charger in life support or healthcare applications where a malfunction or failure of a Tripp Lite RV Inverter Charger could cause failure of or significantly alter the performance of a life support device or medical equipment You may experience uneven performance results if you connect a surge suppressor line conditioner or UPS system to the output of the Inverter Charger Tripp Lite recommends wiring the AC output to a GFCI protector ground fault circuit interrupter e The main grounding lug should be connected to the vehicle chassis with an 8 AWG wire minimum Operation Warnings e Your Inverter Charger does not require routine maintenance Do not open the device for any reason There are no user serviceable parts inside e Potentially lethal voltages exist within the Inverter Charger as long as the battery supply and or AC input are connected During any service work the battery supply and AC input connection if any should therefore be disconnected Do not connect or disconnect batteries while the Inverter Charger is operating in either inverting or charging mode Operating Mode Switch should be in the OFF position Dangerous arcing may result Feature Identification Identify the premium features on your specific model and quickly locate instructions on how to maximize their use Configuration DIP Switches optimize Inverter Charger operation depending on your application See Configuration section for sett
29. Owner s Manual ST e PowerVerter QD RV Series v 3 TRIPP LITE DC to AC Inverter Chargers 1111 W 35th Street Chicago IL 60609 USA Input Output Customer Support 773 869 1234 Invert 12 VDC 120V 60 Hz AC c US www tripplite com Charge 120V 60 Hz AC 12 VDC Quiet Mobile Power Congratulations You ve purchased the most advanced feature rich Inverter Charger designed for recreational applications Tripp Lite RV Inverter Chargers are the quiet alternative to generators with no fumes fuel or noise to deal with You get AC electricity anywhere and anytime you need it away from shore power rolling down the highway dry camping in majestic back country or overnighting at a non electric site Your Tripp Lite Inverter Charger provides your appliances equipment and electronics with utility or generator supplied AC electricity filtered through premium ISOBAR surge protection whenever available In addition it automatically powers your craft s 12V system and recharges your connected battery bank doing what traditional converter chargers do Whenever power blackouts brownouts or high voltages occur your Inverter Charger immediately and automatically switches over to inverting battery output to power connected AC equipment Better for Your Equipment Premium Protection Levels e Built In ZSOBAR Surge Protection e Automatic Overload Protection Ideal Output for All Loads e Frequency Controlled Output e Automatic Load Sw
30. ants indicateurs Votre chargeur onduleur ainsi qu un module optionnel de commande distance Tripp Lite vendu s par ment ou inclus avec les mod les Select est quip d un ensemble de voyants indicateurs simple intu itif et convivial Ces voyants feux de circulation faciles se rem morer vous permettront peu apr s un premier usage de savoir d un coup d il de nombreux d tails de fonctionnement DEL vert de LIGNE Si le commutateur de mode fonctionnement est sur AUTO REMOTE cette lumi re sera ALLUMEE CONTINUELLE MENT quand votre quipement connect recevra une alimentation continue CA de secteur ou fournie par une g n ratrice Si le commutateur de mode fonctionnement est sur CHARGE ONLY cette lumi re CLIGNOTERA pour vous avertir que le con vertisseur de l unit est OFF arr t et N alimentera PAS en CA l quipement en l absence d une source de secteur g n ratrice ou dans des situations de sous ou de surtension DEL jaune INV inversion Cette lumi re sera ALLUMEE CONTINUELLEMENT chaque fois que l quipement connect re oit un alimentation CA invers des batteries en l absence d une source LE secteur g n ratrice ou dans des situations de sous ou mn de surtension Cette lumi re sera teinte quand la charge est aliment e en CA Cette lumi re CLIGNOTERA pour vous avertir que la charge est inf rieure au r glage de conservation d tection
31. applicable electrical codes and requirements for Connection for Models with Hardwire Terminals Output Connection Requirement UL requires that the output terminals of all hard wire Inverter Charger models must be connected to UL listed GFCI receptacles required receptacle manufacturer model series Hubbell GF8300 or Leviton 6598 Single Input Output Models Input Connect incoming wires to the hot brown J neutral blue u and ground green terminals J le Output Connect outgoing wires to the hot black EJ neutral white o and ground green terminals Replace cover plate and tighten screws If the incoming conduit only contains two wires hot and neutral the incoming conduit must be bonded to the main ground lug on the unit In any case the incoming conduit must be bonded to earth or vehicle ground and the incoming conduit must be bonded to the outgoing conduit HOT IN NEUTRAL IN GROUND IN H J NEUTRAL OUT la a Dual Input Output Models Select models provide higher bypass power capacity by enabling connection of two separate AC input sources These two sources can be either two 120V legs split from a single 240V service with opposite phase on each 120V leg or two different 120V sources The Inverter Charger will only supply 120V output power and WILL NOT provide 240V output eve
32. ateur 105V No A4 en haut amp No A3 en haut 95V No A4 en haut amp No A3 en bas 85V No A4 en bas amp No A3 en haut 75V No A4 en bas amp No A3 en bas r glage d usine 105V La plupart de vos appareils et de l quipement connect s fonctionnera ad quatement quand le point de tension sup rieur d entr e CA de votre chargeur onduleur commutateur DIP 2 du Groupe A est r gl 135 V et que son point de tension inf rieur d entr e CA commu tateur DIP 3 et 4 du Groupe A est r gl 95 V Cependant si l unit passe fr quemment sur batterie cause de variations temporaires de tension basse et elev e qui n auraient que peu d effet sur le fonctionnement de l quipement vous pourriez vouloir ajuster ces r glages En augmentant le point de tension sup rieur d entr e CA ou en abaissant le point de tension inf rieur d entr e CA vous r duirez le nombre de fois o votre unit passe sur batterie cause de variations de voltage Commutateurs DIP du Groupe B Choix du partage de CA OPTIONNEL Votre chargeur onduleur poss de un chargeur de batterie sortie lev e qui peut consommer une quantit importante de puissance CA du secteur ou de la g n ratrice quand il charge son r gime maximal Si la lourde charge lectrique connect e est aliment e en CA plein r gime par votre unit et qu en m me temps cette charge lev e survient le disjoncteur d entr e CA peut sauter entra nant l arr
33. atter ies Voir la section Connexion de batterie pour les directives EH Bornes Entr e Sortie CA raccordement fixe connecte s curitairement le chargeur onduleur un v hicule ou l entr e du syst me lectrique de l installation et sortie recommand e prot g e par un disjoncteur de fuite la terre Voir la section Connexion Entr e Sortie CA pour les directives Disjoncteur r armable prot ge votre chargeur onduleur con tre les dommages dus une panne de chargeur Voir la section Fonctionnement pour les directives de r enclenchement EJ Connecteurde module de commande distance permet la surveillance et le commande l aide d un module optionnel mod le Tripp Lite APSRM4 vendu s par ment ou inclus avec les mod les Select Voir le manuel du propri taire de module distant pour des directives de connexion 9 Commande d tecteur de charge du conservateur de charge de batterie conserve la puissance de la batterie en r glant le niveau de la charge minimale auquel l onduleur du chargeur onduleur s teint automatiquement Voir la section Configuration pour les directives de r glage Cosse principale de mise la terre met correctement la terre le chargeur onduleur au syst me de mise la masse d un v hicule ou la terre Voir la section Configuration pour les directives Ventilateur de refroidissement plusieurs vitesses un ven tilateur silencieux et efficace prolonge la vie de l quip
34. charge May also indicate a battery charger fault exists See Troubleshooting section pe ration continued Resetting Your Inverter Charger to Restore AC Power Your Inverter Charger may cease supplying AC power or DC charging power in order to protect itself from overload or to protect your elec trical system To restore normal functioning Overload Reset Switch operating mode switch to OFF or DC OFF and remove some of the connected electrical load ie turn off some of the AC devices drawing power which may have caused the overload of the unit Wait one minute then switch operating mode switch back to either AUTO REMOTE or CHARGE ONLY Configuration Set Configuration DIP Switches Using a small tool set the Configuration DIP Switches located on the front panel see diagram to optimize Inverter Charger operation depending on your application Refer to the appropriate section to review the instructions for your specific model BATT op CHRG SEE MANU VOLT CURR Group A Dip Switches Group A DIP Switches Using a small tool configure your Inverter Charger by setting the four Group A DIP Switches located on the front panel of your unit see diagram as follows Select Battery Type REQUIRED Gel Cell Select High AC Input Voltage Point 145V All models for Switching to Battery OPTIONAL CAUTION The Battery Type DIP Switch setting must OEM models only
35. charge emp chant des dommages la batterie Le probl em peut tre avec les chargeurs auxiliaires connect s ou avec le chargeur de l unit D connecter tous les chargeurs auxiliaires R armer en mettant le commutateur de mode de fonctionnement sur OFF Attendre une minute et passez sur AUTO REMOTE ou CHARGE ONLY Si l unit reste en mode d arr t apr s plusieurs tentatives de r armement communiquez avec le service la client le de Tripp Lite pour de l aide L unit s est teinte cause d une d charge excessive de la batterie Utilisez un chargeur auxiliaire pour relever la tension de la batterie V rifier les connexions externes de la batterie et le fusible L unit se r arme automatiquement quand la consition est lev e L unit s est teinte cause d une surcharge Les batteries connect es sont mortes R duire la charge R armer en mettant le commutateur de mode de fonctionnement sur OFF Attendre1 minute Commuter sur AUTO REMOTE ou CHARGE ONLY V rifier et remplacer les vieilles batteries Le fusible de la batterie a saut V rifier et remplacer le fusible Le c blage de la batterie est l che V rifier et resserrer ou remplacez le c blage L unit s est teinte cause d une surcharge emp chant des dommages la batterie Le probl me peut provenir des chargeurs auxiliaires connect s ou du chargeur de l unit D conne
36. cter tous les chargeurs auxiliaires R armer en mettant le commutateur de mode de fonctionnement sur OFF Attendre une minute et commuter sur AUTO REMOTE ou CHARGE ONLY Si l unit reste en mode d arr t apr s plusieurs tentatives de r armement communiquez avec le service la client le de Tripp Lite pour de l aide Le disjoncteur du circuit a saut R armer le disjoncteur Les trois DEL BATT VOLT CHRG CURR clignotent lentement clair au 1 2 seconde avec lecommutateur de mode de fonctionnement sur AUTO REMOTE Les trois DEL BATT VOLT CHRG CURR clignotent rapidement clair au 1 4 seconde avec le commutateur de mode de fonctionnement sur AUTO REMOTE La batterie est trop d charg e L unit s teindra pour emp cher des dommages la batterie La batterie est trop charg e L unit s teindra pour emp cher des dommages la batterie Le probl me peut provenir des chargeurs auxiliaires connect s ou du chargeur de l unit Utiliser un chargeur auxiliaire pour relever la tension de la batterie V rifier les connexions externes de la batterie et le fusible L unit se r arme automatiquement quand la condition est lev e D connecter tous les chargeurs auxiliaires R armer en mettant le commutateur de mode de fonctionnement sur OFF Attendre une minute et commuter sur AUTO REMOTE Si l unit reste en mode d arr t apr s plusieurs tentatives de r armeman
37. d appliances and equipment will perform adequately when your Inverter Charger s High AC Input Voltage Point DIP Switch 2 of Group is set to 135V and its Low AC Voltage Input Point DIP Switches 3 and 4 of Group A are set to 95V However if the unit frequently switches to battery power due to momentary high low line voltage swings that would have little effect on equipment operation you may wish to adjust these settings By increasing the High AC Voltage Point and or decreasing the Low AC Voltage Point you will reduce the number of times your unit switches to battery due to voltage swings Group B DIP Switches Select AC Sharing OPTIONAL Your Inverter Charger features a high output battery charger that can draw a significant amount of AC power from your utility source or generator when charging at its maximum rate If your unit is supplying its full AC power rating to its connected heavy electrical loads at the same time as this high charging occurs the AC input circuit breaker could trip resulting in the complete shut off of pass through utility power To reduce the chance of tripping this breaker all RV Inverter Chargers may be set to automatically limit the charger output This keeps the sum of the unit s AC load and charge power within the circuit breaker rating This charger limiting function has four settings allowing you to reduce the charger s draw lower and lower as needed if the AC input circuit breaker keeps tripping under the n
38. de charge de la charge de batterie DEL rouge LOAD Cette lumi re rouge sera ALLUMEE CONTINUELLEMENT chaque fois que l onduleur fonctionne et que la puissance demand e par les appareils et l quipement connect s exc de les 100 de la capacit de charge Cette lumi re CLIG NOTERA pour vous avertir que l onduleur s est arr t cause d une s v re surcharge ou surchauffe Si cela arrive tourner le commutateur de fonctionnement sur OFF enlever la surcharge et laisser l unit refroidir Vous pourrez ensuite tourner le commutateur de fonctionnement sur AUTO REMOTE ou CHARGE ONLY apr s que l unit a suffisament refroidi Cette lumi re sera teinte quand la charge est aliment e en CA DEL de TENSION DE BATTERIE BATT VOLTAGE Si le commutateur de mode de fonctionnement est AUTO REMOTE Automatique distance ou la position Charge Only charger seulement les DEL indiquent le niveau approximatif de charge et la tension de votre groupe de batteries connect et vous signale plusieurs conditions de d faut Voir le tableau pour les niveaux de charge et de tension Fonction DEL avec le commutateur sur AUTO REMOTE gt or CHARGE ONLY Niveau de charge approximatif de la batterie Capacit de DEL la batterie allum es Charge d charge Verte 91 Pleine 81 90
39. droits r serv s Power Verter marque enregistr e de Tripp Lite Garantie limit e Tripp Lite garantit que ses chargeurs onduleurs sont exempts de d fauts de mat riel et de fabrication pendant une p riode de 30 mois partir de la date d achat au d tail par l utilisateur Dans le cadre de cette garantie l obligation de Tripp Lite est limit e la r paration ou au remplacement son choix des produits d fectueux Pour b n ficier d un service dans le cadre de cette garantie Vous devez obtenir un num ro d autorisation de retour de mat riel RMA de Tripp Lite ou d un centre de service autoris par Tripp Lite Les produits doivent tre renvoy s Tripp Lite ou un centre de service autoris par Tripp Lite avec les frais de port pr pay s et doivent tre accompagn s d une br ve description du probl me et de la preuve de la date et du lieu de l achat Cette garantie ne s applique l quipement endommag par accident n gligence ou mauvais usage ou qui a t modifi d une quel conque fa on y compris l ouverture du bo tier de l unit quelque soit la raison Seul l acheteur initial qui a enregistr correctement le produit dans les dix jours de l achat peut b n ficier de cette garantie L EXCEPTION DE CE QUI EST CONTENU DANS LA PRESENTE TRIPP LITE N OFFRE AUCUNE GARANTIE EXPRESSE OU IMPLICITE Y COMPRIS LES GARANTIES DE QUALIT MARCHANDE OU DE CONFORMIT UN BESOIN PARTICULIER Certains tats ne permettent
40. e center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase This warranty does not apply to equipment which has been damaged by accident negligence or misapplication or has been altered or modified in any way including opening of the unit s casing for any reason This warranty applies only to the original purchaser who must have properly registered the product within 10 days of retail purchase EXCEPT AS PROVIDED HEREIN TRIPP LITE MAKES NO WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically Tripp Lite is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identification your Tripp Lite product has been assigned a unique series num ber The series number can b
41. e found on the product nameplate label along with all required approval markings and information When requesting compliance information for this product always refer to the series number The series number should not be confused with the marking name or model number of the product Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice WARRANTY REGISTRATION Visit www tripplite com warranty to register the warranty of your new Tripp Lite product You ll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product No purchase necessary Void where prohibited Some restrictions apply See website for details Note on Labeling two symbols are used on the RV labels V AC Voltage V pe Voltage Important Safety Instructions VAN SAVE THESE INSTRUCTIONS This manual contains important instructions and warnings that should be followed during the installation operation and storage of all Tripp Lite Inverter Chargers Note For Marine installations please replace this page with the page titled For Marine Applications Only found in the Owner s Manual Addendum Location Warnings Although your Inverter Charger is moisture resistant it is NOT waterproof Flooding the unit with water will cause it to short circuit and could cause personal injury due to electric shock Never immerse the unit and avoid any area where standing water might accumulate
42. e generator ON OFF switching mechanism with user supplied cable see Pin Configuration Diagram Once 5 Nom Closed attached the interface will allow the Inverter Charger to automatically switch a vehicle generator on when connected bat Nornaly Opi tery voltage levels are low 11 6 VDC and switch it off when battery voltage levels are high 14 1 VDC Or rear 1250 model Battery Selection Select Auxiliary Battery Type if any Select Deep Cycle batteries to receive optimum performance from your Inverter Charger Do not use ordinary car or starting batteries or batteries rated in Cold Cranking Amps CCA If the batteries you connect to the Inverter Charger are not true Deep Cycle batteries their operational lifetimes may be significantly shortened If you are using the same battery bank to power the Inverter Charger as well as DC loads your battery bank will need to be appropriately sized larger loads will require a battery bank with a larger amp hour capacity or the operational lifetimes of the batteries may be significantly shortened Batteries of either Wet Cell vented or Gel Cell Absorbed Glass Mat sealed construction are ideal 6 volt golf cart Marine Deep Cycle or 8D Deep Cycle batteries are also acceptable You must set the Inverter Charger s Battery Type DIP Switch see Configuration section for more information to match the type of batteries you connect or your batter
43. ement Couvercle d Entr e Sortie CA raccordement fixe Connecteur de detection de temp rature de batterie pas sur les mod les 750 prolonge la vie de la batterie en ajustant la charge en fonction de la temp rature de la batterie Utilis avec un c ble compris sur les mod les Select Voir la section Configuration pour les d tails Connecteur de d marrage automatique de g n ratrice par sur les mod les 750 man uvre automatiquement la g n ra trice selon la tension de la batterie Usage avec un c ble fourni par l utilisateur Voir la section Configuration pour les d tails OFF Arr t Arr te l alimentation de l unit et de la sortie CA sur la plupart des mod les DC OFF Arr t CC Arr te l alimentation de l unit et connecte la sortie CA l entr e CA sur les mod les choisis Montage lat ral non montr Montage lat ral non montr COPPER WIRE ony J NEUTRAL OUT HOT IN NEUTRAL IN GROUND IN GRounD out HOT OUT Ve L S Vue avant Mod les raccordement fixe une seule Entr e sortie Vue avant Mod les raccordement fixe deux Entr es Sorties Vue arri re Mod les raccordement fixe une seule Entr e sor
44. ent in the absence of a utility generator source or in over under voltage situations OFF most models Switch to this mode to shut down the Inverter Charger completely preventing the inverter from drawing power from the batteries and preventing utility AC from passing through to dd connected equipment or charging the batteries Use _ this switch to automatically reset the unit if it shuts down due to overload or overheating First remove the excessive load or allow the unit to sufficiently cool applicable to your situation Switch to OFF then back to AUTO REMOTE or CHARGE ONLY as desired If unit fails to reset remove more load or allow unit to cool further and retry Use an optional remote control module Tripp Lite model APSRM4 sold separately or included with select models to reset unit due to overload and overtemperature AUTO OFF CHARGE REMOTE ONLY AUTO OFF CHARGE REMOTE ONLY A DC OFF select models De energizes unit and connects AC our to AC n Indicator Lights Your Inverter Charger as well as an optional Tripp Lite Remote Control Module sold separately or included with select models is equipped with a simple intuitive user friendly set of indicator lights These easily remembered traffic light signals will allow you shortly after first use to tell at a glance a wide variety of oper ating details LINE Green LED If the operating mode switch
45. entrant ne contient que deux fils vivant et neutre il doit tre li la cosse principale de mise la terre de l unit Dans tous les cas le tube protecteur doit tre mis la terre ou la masse du v hicule et il doit tre mis la masse avec le tube protecteur sortant Mod les double entr e sortie Les mod les Select fournissent une capacit sup rieure d alimentation de d rivation en tab lissant la connexion deux sources d entr e s par es Ces deux sources peuvent tre soit deux lignes de 120 V provenant de la division d une ligne unique de 240V les lignes de 120V en opposition de phase soit deux diff rents sourves de 120 V Le chargeur onduleur alimentera seulement la sortie de 120 V et NE fournira PAS de sortie de 240V m me si il est connect aux entr s d une ligne partag e de 240 V quand il est en mode de conversion Qunad le chargeur onduleur re oit une alimentation CA il peut fournir jusqu 30 A aux charges con nect es sur chaque circuit Quand le chargeur onduleur ne re oit pas d alimentation CA et a commut sur l alimentation de conversion CC par batterie il peut fournir diff rents niveaux d amp rages aux charges connect es voir courant de sortie CA maximal dans la section sp cifications sur LES DEUX circuits Les mod les double entr e sortie ali mentent soit a des entr es et sorties source double b une entr e et sortie source sim ple ou c Une entr e source simple et
46. er Rating given your application divide your required battery amp hours from step 3 above by your Inverter Charger s rated charging amps see separate Specifications Sheet NOTE For Tripp Lite Inverter Chargers providing 1000 watts or less of continuous AC power a full size battery will normally allow sufficient power for many applications before recharging is necessary For mobile applications if a single battery is continuously fed by an alternator at high idle or faster then recharging from utility or generator power may not be necessary For Tripp Lite Inverter Chargers over 1000 watts used in mobile applications Tripp Lite recommends you use at least two batteries if possible fed by a heavy duty alternator anytime the vehicle is running Tripp Lite Inverter Chargers will provide adequate power for ordinary usage within limited times without the assistance of utility or generator power However when operating extremely heavy electrical loads at their peak in the absence of utility power you may wish to assist your batteries by running an auxiliary generator or vehicle engine and doing so at faster than normal idling WARNING Mount your Inverter Charger BEFORE DC battery and AC power connection Failure to follow these instructions may lead to personal injury and or damage to the Inverter Charger and connected systems A Tripp Lite manufactures a variety of different Inverter Chargers with a variety of different mountin
47. etermine DC Battery Amps Required Divide the total wattage required from step 1 above by the battery voltage 12 540 watts 12V to determine the DC amps required e STEP 3 Estimate Battery Amp Hours Required for operation unsupported by the alternator Multiply the DC amps required from step 2 above by the number of hours you estimate you will operate your equipment exclusively from battery power before you have to recharge your batteries with utility or generator supplied 45 DC Amps x 5 Hrs Runtime AC power Compensate for inefficiency by multiplying this number by 1 2 x 1 2 Inefficiency Rating This will give you a rough estimate of how many amp hours of battery power from one or several batteries you should connect to your Inverter Charger NOTE Battery amp hour ratings are usually given for a 20 hour discharge rate Actual amp hour capacities are less when batteries are discharged at faster rates For example batteries discharged in 55 minutes provide only 50 of their listed amp hour ratings while batteries discharged in 9 minutes provide as little as 30 of their amp hour ratings STEP 4 Estimate Battery Recharge Required Given Your Application You must allow your batteries to recharge long enough to replace the charge lost during inverter operation or else you will eventually run down your batteries 270 Amp Hours 55 Amps To estimate the minimum amount of time you need to recharge your batteries Inverter Charg
48. fications sont sujettes modification sans pr avis Remarque sur l tiquetage Deux symboles sont utilis s sur les tiquettes de VR V Voltage CA V Voltage CC Tableau des calibres minimaux de c ble CC recommand s utiliser selon les directives de c blage CC dans la section Connexion de la batterie Tension CC du chargeur onduleur 12 V Calibre du fil vs la distance maximale de l unit la batterie Double 00 2 0 00 2 0 RV20120EM amp RV30120EM seulement 15 pi 39pi 62pi 79 pi 11 pi 28pi 44pi 56 pi L N R 20pi 31 pi 39 pi N R NR 16 pi 20pi N R N R 13 pi 16 pi N R NR 10pi 13pi 1111 W 35th Street Chicago IL 60609 USA N R Non Recommand REMARQUE La puissance acceptable est directement relative la longueur du c ble plus le c ble est court Support la client le 773 869 1234 meilleure est la performance www tripplite com 200607168 93 2592
49. for assistance Unit has shut down due to excessive battery discharge Use an auxiliary charger to raise battery voltage Check external battery connections and fuse Unit automatically resets when condition is cleared Unit has shut down due to overload Connected batteries are dead Reduce load Reset by moving Operating Mode Switch to OFF Wait 1 minute Switch to AUTO REMOTE or CHARGE ONLY Check and replace old batteries Battery fuse is blown Check and replace fuse Battery cabling is loose Check and tighten or replace cabling Unit has shut down due to battery overcharge preventing battery damage The problem may be with connected auxiliary chargers if any or with the unit s charger Disconnect any auxiliary chargers Reset by moving Operating Mode Switch to OFF Wait 1 minute and switch to AUTO REMOTE or or CHARGE ONLY If unit remains in shutdown mode after several attempts to reset contact Tripp Lite Customer Service for assistance Input circuit breaker is tripped Reset circuit breaker All Three BATT VOLT CHRG CURR LEDs are slowly flashing 2 second flashes with Operating Mode Switch in the AUTO REMOTE position All Three BATT VOLT CHRG CURR LEDs are rapidly flashing 14 second flashes with Operating Mode Switch in the AUTO REMOTE position Red LOW Battery Indicator Light is flashing with Ope
50. g options for use in vehicular or non vehicular applications Tripp Lite recommends permanent mounting of your Inverter Charger in any of the configurations illustrated below User must supply mounting hardware and is responsible for determining if the hardware and mounting surface are suitable to support the weight of the Inverter Charger Contact Tripp Lite if you require further assistance in mounting your Inverter Charger 750 amp 1250 Models Only Whether mounted horizontally or vertically the Inverter must be located in an enclosed compartment shielded from outside weather conditions Using the measurements from the diagram install two user sup plied 1 4 6 mm fasteners into a rigid horizontal surface leaving the heads slightly raised E Slide the Inverter Charger back over the fasteners to engage the mounting slots molded on the bottom of the Inverter Charger cabinet Install and tighten two user sup plied 1 4 6 mm fasteners into the mounting feet molded on the front of the Inverter Charger cabinet The polycarbonate cabinet and mounting feet of your Inverter Charger are durable enough to allow for vertical mount ing as well if your vehicle compartment requires this configura tion For vertical mounting the control panel of the Inverter Charger should face up Allow 2 minimum front and rear clearance for adequate ventilation i i H 4 5 in GTA om a 6 75 in 17 1 cm All Models
51. garde concernant la connexion de la batterie e Le chargeur onduleur ne fonctionnera pas avec ou sans alimentation avant que les batteries soient connect es e Les syst mes batteries multiples doivent consister en batteries de tension d ge de capacit amp re heure et de type identiques e Parce que l hydrog ne explosif peut s accumuler pr s des batteries si elles ne sont pas bien a r es vos batteries ne doivent pas tre install es que ce soit pour une application mobile ou stationnaire dans un compartiment sans circulation d air Id alement un compartiment devrait avoir un ventilation d air ext rieur e La connexion finale de la batterie peut causer des tincelles Toujours observer la bonne polarit en connectant les batteries e Ne pas laisser des objets faire contact entre les deux bornes d entr e CC Ne pas relier ces bornes ensemble Il pourrait en r sulter des blessures et des dommages la propri t Mises en garde concernant la connexion de l quipement Ne pas utiliser un chargeur onduleur RV Tripp Lite dans les applications de survie ou de soins de sant o un mauvais fonctionnement ou une panne du chargeur onduleur RV Tripp Lite pourraient entra ner une panne du dispositif de survie ou de l quipement m dical ou alt rer sa performance de fa on importante e Vous pourriez exp rimenter des r sultats de performance in gaux si vous branchez un liminateur de surtension un filtre de secteur ou sys
52. ies connect es tant qu il y aura une alimentation CA de secteur ou fournie par une g n ratrice Cependant comme le con vertisseur est l arr t OFF dans ce mode il N alimentera PAS en CA l quipement connect en l absence d une source secteur g n ra trice ou dans des situations de sous ou de surtension OFF arr t la plupart des mod les Commuter vers ce mode pour fermer compl tement le chargeur onduleur emp chant l onduleur de tirer du courant des batteries et emp chant aussi que le courant du secteur se rende l quipement connect ou de nem 7 swt charger les batteries Utiliser ce commutateur pour r activer automatiquement l unit si elle s est arr t e cause d une surcharge ou d une surchauffe Enlever d abord la charge exc dentaire ou laiss er l unit se refroidir suffisament selon votre situation Commuter sur OFF puis revenez AUTO REMOTE ou CHARGE ONLY comme d sir si l unit ne se r active pas enlever plus de charge ou laissez la se refroidir plus longtemps et recommencer Utilisez un module optionnel de commande distance mod le Tripp Lite APSRM4 vendu s par ment ou inclus avec les mod les Select pour r activer l unit en cas de surcharge ou de surchauffe AUTO OFF CHARGE REMOTE ONLY AUTO OFF CHARGE REMOTI ONLY Am DC OFF Arr t CC Mod les choisis Arr te l alimentation de l unit et connecte la sortie CA l entr e CA Voy
53. ies may be degraded or damaged over an extended period of time In many cases the vehicle battery may be the only one installed Auxiliary batteries must be identical to the vehicle batteries if they are con nected to each other Match Battery Amp Hour Capacity to Your Application Select a battery or system of batteries that will provide your Inverter Charger with proper DC voltage and an adequate amp hour capacity to power your application Even though Tripp Lite Inverter Chargers are highly efficient at DC to AC inversion their rated output capacities are limited by the total amp hour capacity of connected batteries and the support of your vehicle s alternator if the engine is kept running Example Tools STEP 1 Determine Total Wattage Required Add the wattage ratings of all equipment you will connect to your Inverter Charger Wattage ratings are usually listed in equipment manuals or on nameplates If your equipment is rated in amps multiply that number times AC utility voltage to determine watts Example a in drill requires 2 amps 2 amps x 120 volts 300 watts Drill Orbital Sander Cordless Tool Charger elle om T 7 la t Note Your Inverter Charger will operate at higher efficiencies at about 75 80 of nameplate rating 300W 5 220W a 20W je EU Appliances Blender Color TV Laptop Computer gt aay wn 300W 140W EUR e STEP 2 D
54. ing instructions Operating Mode Switch controls Inverter Charger operation The AUTO REMOTE setting ensures your equipment receives constant uninterrupted AC power It also enables the Inverter Charger to be remotely monitored and controlled with an optional remote module Tripp Lite model APSRM4 sold separately or included with select models The CHARGE ONLY setting allows your batteries to return to full charge faster by turning the inverter off which halts battery discharging See Operation section for setting instructions LINE INVERT LOAD LEDs intuitive traffic light signals show whether the Inverter Charger is operating from AC line power or DC battery power It also warns you if the connected equipment load is too high See Operation section for instructions on reading the indicator lights BATT VOLTAGE LEDs these three lights will turn ON in several sequences to show approximate battery level See Operation section for instructions on reading the indicator lights a DC Power Terminals connect to your battery terminals See Battery Connection section for instructions EH Hardwire AC Input Output Terminals securely connect the Inverter Charger to vehicle or facility electrical system input and recommended GFCI protected output See AC Input Output Connection section for instructions Resettable Circuit Breaker protect your Inverter Charger against damage due to charger failure See O
55. itching e Balanced Load Sharing Better for Your Batteries Faster Battery Recharge e High Amp 3 Stage Battery Charger adjustable Critical Battery Protection e Battery Charge Conserver Load Sense Battery Temperature Sensing e High Efficiency DC to AC Inversion Better for You Quiet Simple Maintenance Free Operation e Multi Function Lights amp Switches e Automatic Generator Starting e Moisture Resistant Construction Warranty Warranty Registration 2 Mounting 10 Safety 3 Battery Connection 11 Feature Identification 4 AC Input Output Connection 12 Operation 5 6 Service Maintenance 13 Configuration 6 8 Troubleshooting 13 Battery Selection 9 Francais 14 Available on all models except 750 models Inverter Chargers are moisture resistant not waterproof Copyright 2006 All rights reserved Power Verter is a registered trademark of Tripp Lite Limited Warranty Tripp Lite warrants its Inverter Chargers to be free from defects in materials and workmanship for a 30 month period from the date of retail purchase by end user Tripp Lite s obligation under this warranty is limited to repairing or replacing at its sole option any such defective products To obtain service under this warranty you must obtain a Returned Material Authorization RMA number from Tripp Lite or an authorized Tripp Lite service center Products must be returned to Tripp Lite or an authorized Tripp Lite servic
56. ler la commande de conservation de charge de batterie D tecteur de charge OPTIONNEL Dans le but de sauvegarder la puissance de la batterie l onduleur de l unit s arr te automatiquement en l absence de demande d alimentation d un quipement ou d appareils connect s la charge lectrique Quand l unit d tecte une charge il met en marche automatiquement la fonction de l onduleur L utilisateur peut choisir la charge minimale que le chargeur onduleur d tectera en r glant la commande de conservation de charge de batterie voir sch ma A l aide d un petit outil tourner la commande dans le sens horaire pour abaisser la charge minimale qui sera d tect e entra nant la mise en marche l onduleur pour de plus petites charges Quand la rotation du cadran dans le sens horaire est compl te l onduleur fonction nera m me sans charge Tourner le cadran dans le sens antihoraire pour augmenter la charge minimale qui sera d tect entra nant la mise l arr t l onduleur jusqu ce que la nouvelle charge minimale soit atteinte Remarque Le r glage en usine est la rotation compl te du cadran dans le sens horaire Cependant en fonction du seuil de charge auquel vous voudriez que l onduleur r ponde vous devez r gler le cad ran dans le sens antihoraire pour r duire sa sensibilit jusqu ce que l onduleur soit actif seulement quand l quipement et les appareils connect s sont r ellement en usage Connexion de la commande distance
57. les enlever Le cabinet de polycarbone et le pied de sup port de votre circuit inverseur chargeur sont suffisamment robustes pour vous permettre un montage vertical si le compar timent de votre v hicule requiert cette configuration Pour le montage vertical le panneau de contr le du circuit inverseur chargeur doit faire face au haut Laisser 5 cm 2 po au moins de jeu l avant et l arri re pour une bonne ventilation gt 5 57 in 3 te om El oson 7 435m 5 a in a7 in 24 85 om 91 cm 557 A Nain D E 14 91 cm 41 64 in 4 15 cm Remarque Les bo tiers mod le VR peuvent avoir diff rentes caract ristiques du panneau avant Tous les mod les poss dent des pieds de fixation l avant et l arri re Les mod les Select poss dent des pieds de fixation lat raux Connexion de la batterie Connexion de votre chargeur onduleur vos batteries selon les proc dures suivantes Puisque e Connexion du c blage CC votre chargeur ond uleur est un conver tisseur hautement efficace d lectric it sa capacit nominale de sortie est limit e par la longueur et le cali bre du c blage reliant la batterie l unit Uilisez le c blage le plus court et du plus remarque au bas de la page gros diam tre calibre maximal 2 0 pour fixer aux bornes CC de votre chargeur ond uleur Un c blage plus court et de plus gros calibre r duit la baisse de tension CC e
58. n if it is connected to inputs from a split 240V service when in inverter mode When the Inverter Charger is receiving AC power it can supply connected loads with up to 30 amps of power on each circuit When the Inverter Charger is not receiving AC power and has switched to inverting DC battery power it can supply connected loads with various amper ui HET age levels see Maximum Output AC Current in Specifications section on BOTH circuits Dual input output models provide for either a dual source inputs and outputs b single source input and output or c single source input and dual source outputs with AC OUT 2 power only available in invert mode Connect user supplied wire and conduit to the con nections as follows Input Connect incoming wires to hot black for AC IN 1 black for AC IN 2 neutral white for AC IN 1 white for AC IN 2 and ground green yellow wires Output Connect outgoing wires to hot black for AC OUT 1 black for AC OUT 2 neutral white for AC OUT 1 white for AC OUT 2 and ground green yellow wires Dual Source Input Output Single Source Input Output e AC IN 1 will only provide line power to AC OUT 1 e If you only have a single 120V AC input source you must e AC IN 2 will only provide line power to AC OUT 2 connect it to AC IN 1 e Inverted battery power i
59. n one positive cable through one user supplied UL listed fuse and fuse block AC Input Output Connection To avoid overloading your Inverter Charger match the power requirements of the equipment you plan to run at any one time add their total watts with the output wattage capacity of your Inverter Charger model see Specifications Do not confuse continuous wattage with peak wattage ratings Most electric motors require extra power at start up peak wattage than required to run continuously after start up sometimes over 100 more Some motors such as in refrigerators and pumps start and stop intermittently according to demand requir ing peak wattage at multiple unpredictable times during operation DoubleBoost Feature Tripp Lite Inverter Chargers deliver up to twice their nameplate rated wattage for up to 10 seconds providing the extra power needed to cold start heavy duty tools and equipment OverPower Feature Tripp Lite Inverter Chargers deliver up to 150 of their name plate rated wattage for up to 1 hour providing plenty of reserve power to reliably support tools and equipment longer Actual duration depends on model battery age battery charge level and ambient temperature hardwire connection Disconnect both DC input and AC utility supply before attempting hardwiring Use wire type THHN or equivalent with minimum temperature rating of 90 C Warning Consult a qualified electrician and follow all
60. nale de sortie est limit e par la capacit totale en A h des batteries connect es et le support de l alternateur de votre v hicule si le moteur est en marche Exemple e TAPE 1 D termination du wattage total requis Outils Additionnez les puissances nominales de tout l quipement connect a votre Perceuse 1 4 po Ponceuse orbitale Chargeur d outil sans fil chargeur onduleur Les puissances nominales sont g n ralement indiqu es dans les A manuels d quipement ou sur les plaques signal tiques Si votre quipement est a i indiqu en amp res multiplier le nombre d amp res par 120 pour calculer la puis qe z sance Exemple Une perceuse 1 4 po a besoin de 2 5 A 2 5 A o 120 volts 300 watts 300W 220W 20W EU Remarque Votrechargeur onduleur sera plus efficace entre 75 et 80 de la puissance indiqu e sur Appareils la P laque signal tique M langeur TV couleur Ordinateur portable Lt 300W 140w ow JETTA e TAPE 2 D termination de l intensit de la batterie requise en CC Divisez le wattage total requis d apr s l tape 1 ci dessus par le voltage de la bat 540 watts 12V Zo Wee terie 12 pour d terminer l intensit CC requise e TAPE 3 Estimation des A h de batterie requis pour un fonctionnement non support par l alternateur Multipliez l intensit requise d apr s l tape 2 ci dessus par le nombre estim d heures du fonctionnemen
61. o cable length i e the shorter the cable the better the performance Sp cifications Fran ais NUM RO DE MOD LE RV750ULHW RV1250ULHW RV2012UL RV20120EM RV30120EM Num ro de s rie AGAP5088 AGAP5094 AP5626 AGAP200012MVP3 AGAP4669 Connexion d entr e CA Raccordement fixe Raccordement fixe Raccordement fixe Raccordement fixe Raccordement fixe ONDULEUR Sp cifications courantes pour tous les mod les Tension d entr e CC nominale 12 V CC Plage de tension d entr e CC 10 15 V CC Tension de sortie CA nominale 120 VAC 5 Fr quence de sortie nominale 60 Hz 0 5 Efficacit 88 94 d pendant de la charge et de la temp rature Les chargeurs onduleurs de Tripp Lite sont quip s d une commande de conservation de charge de batterie d tecteur de charge qui conomise la batterie en permettant l utilisateur de r gler le niveau de charge mini mal auquel l onduleur de l unit se met en marche Les utilisateurs peuvent r duire le courant d entr e CC sans charge environ 1 3 A pour tous les mod les un niveau tr s bas l aide de cette commande Alimentation continue 20 C 750 1250 2000 2000 3000 Puissance de surtension 1125 1875 3000 3000 4500 depointe OverPower Puissance de surtension de 1500 2500 4000 4000 6000 pointe Double Boost Courant CA de sortie maximal 6 3 A 10 4 A 16 7 A 16 7 A 25 A Continu Fusible CC homologu 125A
62. omme le sont les deux bornes n gatives Dans cette connexion vous devez relier un c ble positif par l interm diaire d un fusible ou d un bloc fusibles UL fourni par l utilisateur Connexion d Entr e Sortie CA Pour viter de surcharger votre chargeur onduleur faire correspondre les exigences de puissance de l quipement que vous voulez faire fonction ner en tout temps additionnez leurs watts avec la puissance de votre mod le de chargeur onduleur voir les sp cifications Ne pas confondre les puissances nominales de wattage continu et de wattage de pointe Le plupart des moteurs lectriques ont besoin de plus de puissance au d marrage wattage de pointe qu il n est n cessaire pour un fonctionnement continu quelquefois au del de 100 de plus Certains moteurs commes les r frig rateurs et les pompes d marrent et s arr tent de mani re intermittente selon la demande n cessitant du wattage de pointe de nombreux moments impr visibles pendant leur fonctionnement Caract ristique DoubleBoost Les chargeurs onduleurs Tripp Lite peuvent fournir jusqu deux fois le wattage nominal de leur plaque signal tique pendant 10 secondes fournissant ainsi la puissance n ces saire pour d marrer froid des outils et de l quipement lourds Caract ristique OverPower Les chargeurs onduleurs Tripp Lite peuvent fournir jusqu 150 du wattage nominal de leur plaque signal tique pendant 1 heure fournissan
63. ormal AC loads of devices you have connected downline from the unit The figures show how to set your DIP Switches for charger limiting All Models All Models except RV2012UL amp RV30120EM Select Battery Charger Limiting Points OPTIONAL Least Limiting B2 Down amp B1 Up Charger limiting begins when the Inverter Charger s load reaches 66 of the Most Limiting B2 amp B1 Up B3 B2 B1 Charger limiting takes effect the moment aam Inverter Charger s load rating Charger any 120V AC load is applied charger out output falls gradually from full output at put falls gradually from full output at no 66 of the Inverter Charger s load rating to about 40 of full out 120V load passing through to no output at put at full load full load No Limiting B2 amp B1 Down No Less Limiting B2 Up amp B1 Down Ba charger limiting occurs at any load size Charger limiting begins when the Inverter Charger s load reaches 33 of the Inverter Charger s load rating Charger output falls gradually from full output at 33 of the Inverter Charger s load rating to about 40 of full output at full load Most models are factory preset to Most Limiting RV20120EM is preset to Less Limiting RV2012UL and RV30120 EM models can only be set to Most Limiting or Less Limiting B2 switch is non functional Configuration continued Select Equalize Battery Charge
64. ote control module Tripp Lite model APSRM4 sold separately or included with select models The remote module allows the Inverter Charger to be mounted in a compartment or cabinet out of sight while operated conveniently from within the living area or control panel of your RV See instructions packed with the remote control module Connect Battery Temperature Sensing Cable OPTIONAL not on 750 models The battery temperature sensing function prolongs battery life by adjusting the charge float voltage level based on battery temperature Connect the sensor cable the cable included with select models has an RJ style connector on one end and a black sensor on the other to the RJ style jack located on the side of the Inverter Charger labeled Remote Temp Sense With user supplied electrical or duct tape affix the sen sor to the side of the battery below the electrolyte level Make sure that nothing not even tape comes between the sensor and the side of the bat tery To guard against false readings due to ambient temperature place the sensor between batteries if possible or away from sources of extreme heat or cold If the sensor cable is not used the Inverter Charger will charge according to its default 25 C values Utilize Automatic Generator Starter Capability OPTIONAL not on 750 models bag See All models except 750 models include an RJ type modular jack on the side panel labeled Generator Start Attach to vehi 2 Common cl
65. peration section for resetting instructions E Remote Control Module Connector allows remote monitoring and control with an optional module Tripp Lite model APSRM4 sold separately or included with select models See remote module owner s manual for connection instructions E Battery Charge Conserver Load Sense Dial conserves battery power by setting the low load level at which the Inverter Charger s inverter automatically shuts off See Configuration section for setting instructions Main Ground Lug properly grounds the Inverter Charger to vehicle grounding system or to earth ground See Configuration section for instructions Multi Speed Cooling Fan quiet efficient fan prolongs equipment service life Hardwire AC Input Output Cover Plate Battery Temperature Sensing Connector not on 750 models prolongs battery life by adjusting charge based on battery tem perature Use with cable included on select models See Configuration section for details Automatic Generator Start Connector not on 750 models automatically cycles generator based on battery voltage Use with user supplied cable See Configuration section for details OFF De energizes unit and AC output on most models DC OFF De energizes unit and connects AC oyr to AC yy on select models Side Mounted Not Shown Side Mounted Not Shown
66. quiert cette configuration Pour le montage vertical le panneau de con tr le du circuit inverseur chargeur doit faire face au haut Laisser 5 cm 2 po au moins de jeu l avant et l arri re pour une bonne ventilation CCB f 114 cm 6 75 in N 17 1 om 4 i i Le i S d 6 75 in 174 7 87 in eee 20 cm en D Tous les Mod les l exception des Mod les 750 et 1250 Note En faisant fonctionner le mod le RV2012UL marine dans une application marine se r f rer au suppl ment du manuel de l utilisateur qui accompagne ces mod les Qu il soit mont horizontalement ou verticalement l Inverseur doit tre situ dans un compartiment clos prot g des conditions m t orologiques l aide des mesures du sch ma installer deux attaches de 6 mm 1 4po fourni par l utilisateur dans une surface horizontale rigide en laissant les t tes d passer l g rement J Glisser le chargeur ond uleur vers l avant par dessus les attaches pour engager les pieds de fixation moul s en avant du bo tier du chargeur onduleur Installer et fixer des attaches suppl mmentaires de 6 mm 1 4po fourni par l utilisateur dans les pieds de fixation moul s l arri re et sur les c t s du bo tier du chargeur onduleur Les pieds arri re se prolon gent au del du bo tier de l unit pour fournir une espace de ventila tion ad quat derri re le s ventilateur s de refroidissement il ne faut pas
67. r entre les batteries si possible ou loin de sources extr mes de chaleur ou de froid Si le c ble du capteur n est pas utilis le chargeur onduleur chargera selon sa valeur par d faut de 25 C Utilisation de la capacit de d marrage automatique de l alternateur pas sur le mod le 750 Tous les mod les l exception des mod les 750 sont quip d un jack modulaire de Type RJ sur la panneau PRE lat ral identifi D marrage de la g n ratrice Connecter le m canisme de commutation ON OFF arr t e marche de l alternateur du v hicule un c ble fourni par l utilisateur voir la configuration de la broche Une dus fois connect e l interface permettra au chargeur onduleur de commuter automatiquement sur l alternateur d un v hicule quand les niveaux de tension de la batterie connect e sont bas 11 6 V CC et de se d brancher quand les niveaux de batterie sont lev s 14 1 V CC NO Normallement ouverte Ou arri re mod le 1250 Choix de batterie Choix du type de batterie auxiliaire s il y en a Choisir des batteries d charge pouss e pour obtenir une performance maximale de votre chargeur onduleur Ne pas utiliser de batterie ordinaire de voiture ou de d marrage ou de batteries not es intensit de d marrage froid Cold Cranking Amps CCA Si les batteries connect es au chargeur ond uleur ne sont pas de vraies batteries d charge pouss e leur dur
68. rating Mode Switch in the AUTO REMOTE position Battery is excessively discharged Unit will shut down to prevent battery damage Battery is overcharged Unit will shut down to prevent battery damage The problem may be with connected auxiliary chargers if any or with the unit s charger Battery voltage is low Unit has shut down to protect battery from damage Use an auxiliary charger to raise battery voltage Check external battery connections and fuse Unit automatically resets when condition is cleared Disconnect any auxiliary chargers Reset by moving Operating Mode Switch to OFF Wait 1 minute and switch to AUTO REMOTE If unit remains in shutdown mode after several attempts to reset contact Tripp Lite Customer Service for assistance If AC power utility or generator supplied is present the unit will automatically reset itself and start recharging connected batteries However if an external charger is used to recharge the batteries you will need to manually reset the unit by moving the Operating Mode Switch to OFF for two seconds then returning it to AUTO REMOTE False reading due to undersized or Use sufficient size DC cable sufficiently connected to insufficiently connected DC cabling Inverter Charger Red LOAD Operation Indicator Light flashing User supplied Inverter is overloaded Unit will automatically shut down after 5 seconds Reduce load Rese
69. re cellule liquide 135V endommag es sur une longue p riode Voir Choix de la batterie p 22 pour plus de renseignements Type de batterie Position du commutateur Tension Position du commutateur Batterie cellule en gel scell e Haut 145V Haut Batterie cellule liquide ventil e Bas r glage d usine 135V Bas r glage d usine Charger Inhibit la plupart des mod les Fonction Switch Position Charger Inhibited Up Charger Enabled Down factory setting La plupart de vos appareils et de l quipement connect s fonctionnera ad quatement quand le point de tension sup rieur d entr e CA de votre chargeur onduleur commutateur DIP 2 du Groupe est r gl 135 V et que son point de tension inf rieur d entr e CA commutateur DIP 3 et 4 du Groupe est r gl 95 V Cependant si l unit passe fr quemment sur batterie cause de variations temporaires de tension basse et elev e qui n auraient que peu d effet sur le fonctionnement de l quipement vous pourriez vouloir ajuster ces r glages En augmentant le point de tension sup rieur d entr e CA ou en abaissant le point de tension inf rieur d entr e CA vous r duirez le nom bre de fois o votre unit passe sur batterie cause de variations de voltage Configuration suite Tous les mod les Choix du point de tension sup rieur d entr e CA pour pass er sur batterie OPTIONNEL Position du Tension commut
70. ripped 2 If the problem continues do not contact or return the Inverter Charger to the dealer Instead call Tripp Lite at 773 869 1233 A service tech nician will ask for the Inverter Charger s model number serial number and purchase date and will attempt to correct the problem over the phone 3 If the problem requires service the technician will issue you a Returned Material Authorization RMA number which is required for service Securely pack the Inverter Charger to avoid damage during shipping Do not use Styrofoam beads for packaging Any damages direct indirect special incidental or consequential to the Inverter Charger incurred during shipment to Tripp Lite or an authorized Tripp Lite service center is not covered under warranty Inverter Chargers shipped to Tripp Lite or an authorized Tripp Lite serv ice center must have transportation charges prepaid Mark the RMA number on the outside of the package If the Inverter Charger is with in the warranty period enclose a copy of your sales receipt Return the Inverter Charger for service using an insured carrier to the address given to you by the Tripp Lite service technician This is a common cause of service inquiries which can be easily remedied by following the resetting instructions in this manual If you require packaging the technician can arrange to send you proper packaging Maintenance Your Inverter Charger requires no maintenance and contains no user ser
71. s charges connect es l entr e 1 CA alimente galement le chargeur de batterie Si vous connectez une lourde charge la sortie 1 CA vous devez choisir un r glage plus restrictif du chargeur de batterie voir Choix des points limite de chargeur de batterie ou vous pourriez exp rimenter un d clenchement con tinuel aga ant du disjoncteur de service lectrique source qui alimente l entr e 1 CA Le chargeur onduleur mesurera seulement le courant la sortie 1 CA pour limiter automatiquement le r gime du chargeur Le courant d entr e de l entr e 1 CA passe par la sortie 2 CA sans tre mesur Connexions Entr e source simple Sortie source double Vous pouvez connecter EN 1 CA et EN 2 CA une seule source pour alimenter les sorties 1 et 2 CA Cependant les charges connect es la sortie 2 CA ne seront pas mesure s dans le but de limiter automatiquement le chargeur Il peut en r sul ter un d clenchement occasionnel du disjoncteur de service lectrique source Si cela arrive r duire la charge de la sortie 2 CA jusqu ce que le d clenchement aga ant cesse Limit par des disjoncteurs fournis par l utilisateur Service Avant d envoyer votre chargeur onduleur pour r parations suivre ces tapes 1 Relire les directives d installation et de fonctionnement pour s assurer que le probl me n a pas pour origine une mauvaise lecture de ces directives V rifier galement que les disjoncteurs ne sont pas d clench s 2
72. s directives de s curit VAN CONSERVEZ CES DIRECTIVES Ce manuel contient d importantes directives et mises en garde que vous devez suivre pendant l installation le fonctionnement et l entreposage de tous les chargeurs onduluers de Tripp Lite Remarque pour les installations marines remplacez cette page par la page titr e Pour les applications marines seulement que vous retrouverez dans l annexe du manuel du propri taire Mises en garde concernant l emplacement e M me si votre chargeur onduleur r siste l humidit il N est PAS tanche Noyer l unit entrainerait un court circuit et pourrait causer des blessures par choc lectrique Ne jamais immerger l unit et viter toute zone o de l eau pourrait s accumuler Il faut la fixer dans la zone la plus s che possible e Laisser un d gagement d au moins 51mm 2 po l avant et l arri re du chargeur onduleur pour une bonne a ration Pour viter la fermeture automatique du chargeur onduleur cause d une surchauffe tout compartiment contenant le chargeur onduleur doit tre correctement a r avec une ventilation ad quate d air ext rieur Plus la charge de l quipement connect est importante plus l unit g n re de chaleur e Ne pas installer le chargeur onduleur pr s d un dispositif de stockage magn tique cela pourrait entra ner de la corruption de donn es e Ne pas installer pr s de mati res inflammables combustible ou produits chimiques Mises en
73. s supplied to both AC OUT 1 and AC OUT 2 e If you only have a single output circuit you must connect it to AC OUT 1 Single Source or Dual Source Input Output Connection As well as supplying power to connected loads AC IN 1 also provides power to the battery charger If you connect a large load to AC OUT 1 you should select a more limiting battery charger setting see Select Battery Charger Limiting Points or you may experience continual nuisance tripping of the electrical service source circuit breaker which supplies AC IN 1 The Inverter Charger will only measure the current at AC OUT I to automatically limit the charger rate AC IN 2 input current is passed through to AC OUT 2 with out measurement Single Source Input Dual Source Output Connection You may connect AC IN 1 and AC IN 2 to a single source to provide power to AC OUT 1 and AC OUT 2 However the loads connected to AC OUT 2 will not be measured for the purpose of automatic charger limitation This could result in occasional tripping of the electrical service source circuit breaker If this occurs reduce the load on AC OUT 2 until nuisance tripping stops Limited by user supplied circuit breakers Service Before returning your Inverter Charger for service follow these steps 1 Review the installation and operation instructions to ensure that the service problem does not originate from a misreading of the instructions Also check that the circuit breaker s are not t
74. st ensure that the amp hour capacity of their battery system exceeds the amperage of the High Charge Amp setting or the batteries may be damaged or degraded High Charge Amp Set Battery Charge Conserver Load Sense Dial OPTIONAL In order to save battery power the unit s inverter automatically shuts off in the absence of any power demand from connected equipment or appliances the electrical load When the unit detects a load it automatically turns its inverter function on Users may choose the minimum load the Inverter Charger will detect by adjusting the Battery Charge Conserver Dial see diagram Using a small tool turn the dial clockwise to lower the minimum load that will be detected causing the inverter to turn on for smaller loads When the dial is turned fully clockwise the inverter will operate even when there is no load Turn the dial counterclockwise to increase the minimum load that will be detected causing the inverter to stay off until the new minimum load is reached Note the factory setting for the dial is fully clockwise However based on the threshold load to which you d like the inverter to respond you should adjust the dial counterclockwise to reduce its sensi tivity until the inverter is active only when connected equipment or appliances are actually in use Connect Remote Contro OPTIONAL All models All models feature an 8 conductor telephone style receptacle on the front panel for use with an optional rem
75. t communiquez avec le service la client le de Tripp Lite pour de l aide Le voyant indicateur LOW de la batterie clignote avec le commutateur de mode de fonctionnement sur AUTO REMOTE La tension de la batterie est basse L unit s est teinte pour prot ger la batterie de dommages Mauvaise lecture cause d un c blage CC insuffisant Si l alimentation AC de secteur ou d une g n ratrice est pr sente l unit se r armera automatiquement et commencera recharger les batteries connect es Cependant si un chargeur externe est utilis pour recharger les batteries vous devrez r armer manuellement l unit en mettant le commutateur de mode de fonctionnement sur OFF pendant deux secondes avant de revenir sur AUTO REMOTE Utiliser un c ble CC de calibre suffisant bien connect au ou mal connect chargeur onduleur Le voyant indicateur de fonctionnement LOAD rouge clignote fourni par l utilisateur L onduleur est en surcharge L unit s teindra apr s 5 secondes R duire la charge R armer en mettant le commutateur de mode de fonctionnement sur OFF Attendre1 minute Commuter sur AUTO REMOTE ou CHARGE ONLY TRIPP LITE 1111 W 35th Street Chicago IL 60609 USA Support la client le 773 869 1234 www tripplite com 200605181 93 2556 Specifications English Model Number RV750ULHW RV1250ULHW RV2012UL RV20120EM RV30120EM
76. t me UPS la sortie de votre chargeur onduleur e Tripp Lite recommande de c bler la sortie CA un disjoncteur de fuite la terre e La cosse principale de mise la terre doit tre connect e au ch ssis du v hicule avec un fil de calibre 8 AWG minimum Mises en garde de fonctionnement e Votre chargeur onduleur ne n cessite pas d entretien de routine N ouvrir l appareil sous aucune raison Aucune pi ce interne n est r parable par l utilisateur e Des tensions mortelles existent potentiellement dans le chargeur onduleur aussi longtemps que le bloc d alimentation par batterie ou l entr e CA est connect Il faut donc d connecter l alimentation par batterie ou la connexion d entr e CA s il y en une pendant tout travail d entretien e Ne pas connecter ou d connecter les batteries pendant que le chargeur onduleur fonctionne soit en mode onduleur soit en mode de charge Le commutateur du mode de fonctionnement doit tre en position OFF ferm Il pourrait se former des arcs lectriques Attention Certains mod les disposent d un dispositif de passage s curit intrins que CA dans lequel la sortie CA sera vivante si l entr e CA est disponible m me si l interrupteur de mode de fonctionnement est plac sur DC OFF Arr t CC Identification des caract ristiques Identifier les caract ristiques de qualit sup rieure sur votre mod le particulier et trouver rapidement les directives sur la mani re de max
77. t ainsi beaucoup de puissance de r serve pour faire fonctionner plus longtemps de mani re fiable des outils et de l quipement La dur e r elle d pend du mod le de l ge de la batterie du niveau de charge de la batterie et de la temp rature ambiante Mise en garde Consulter un lectricien qualifi et suivre tous les codes lectriques applicables et les exigences pour une connexion raccordement fixe D connecter la fois l entr e CC et l ali mentation de secteur CA avant d effectuer un raccordement fixe Utiliser un fil de type THHN ou uivalent supportant une temp rature nominale minimale de 90 C Connexion des mod les avec bornes raccordement fixe Condition De Raccordement De Rendement L UL exige que les bornes de rendement doivent tre reli es aux r ceptacles de GFCI s rie UL num r e requise de r ceptacle manufacturer model Hubbell GF8300 ou Leviton 6598 Mod les simple entr e sortie Entr e Connectez les fils entrants aux bornes vivante brune B neutre bleue A et mise la terre verte Sortie Connectez les fils sortants aux bornes vivante noire El neutre blanche llet mise la terre verte El J NEUTRAL IN GROUND IN tT erouw our J nor our c ey NEUTRAL our a le amp A Replacer le couvercle et serrer les vis Si le tube protecteur
78. t by moving Operating Mode Switch to OFF Wait 1 minute Switch to AUTO REMOTE or CHARGE ONLY Manuel du propri taire PowerVerter S rie RV was TRIPP LITE Chargeurs Onduleurs CC vers CA 1111 W 35th Street Chicago IL 60609 USA Entr e Sortie Support la client le 773 869 1234 Inversion 12V CC 120V 60 Hz CA www tripplite com Charge 120V 60 Hz CA 12V CC C US Alimentation mobile silencieuse F licitations Vous avez achet le circuit inverseur chargeur le plus avanc riche en options con u pour les applications r cr ationnelles Le circuit inverseur chargeur RV de Tripp Lite est l alternative silencieuse aux g n rateurs sans avoir affaire la fum e au carburant ou au bruit Vous obtenez une alimentation lectrique c a en tout temps et partout o vous en avez besoin loin de l alimentation externe en roulant sur l autoroute en camping au fond des bois ou durant la nuit sur un site sans lectricit Votre circuit inverseur chargeur alimente vos lectrom nagers vos quipements et appareils lectroniques d une alimentation c a de service ou provenant d une g n ratrice fil tr travers la protection de surtension ISOBAR lorsque disponible De plus il alimente automatiquement votre syst me de v hicule 12V et recharge votre banque de piles connect es effectuant ce qu un convertisseur chargeur fait Lors des pannes de courant ou s il se produit des affaissements
79. t de surcharge Placer le commutateur de mode de fonctionnement sur OFF ou DC OFF et enlever une partie de la charge lectrique connect e c d fermer certains des appareils CA qui peuvent avoir caus la surcharge de l unit Attendreune minute puis remettre le commutateur de fonctionnement sur AUTO REMOTE ou CHARGE ONLY Configuration R gler les commutateurs DIP de configuration l aide d un petit outil r gler les commutateurs DIP de configuration situ s sur la panneau avant voir sch ma pour optimiser le fonction nement du chargeur onduleur selon votre application Aller la section appropri e pour revoir les directives pour votre mod le CONFIGURATION SWITCHES BATT or CHRG ON VOLT CURR SEE MANUAL INPUT C B X Commutateurs DIP du Groupe B Commutateurs DIP du Groupe A Commutateurs DIP du Groupe A A l aide d un petit outil configurer votre chargeur onduleur en r glant les commutateurs DIP du groupe A situ s sur la panneau avant voir sch ma comme suit Choisir le type de batterie REQUIS er Choix du point de tension sup rieure gt 5 ME M 145V tous les mod les d entr e CA pour passer sur batterie se ATTENTION Le r glage du commutateur DIP de type de OPTIONNEL batterie doit correspondre aux types de batteries que vous mod les OEM seulement connectez ou vos batteries pourraient se d grader ou t
80. t de votre quipement aliment exclusivement par bat terie avant que vous ne deviez recharger vos batteries en CA sur le secteur ou avec A une g n ratrice Compensez pour l inefficacit en multipliant ce chiffre par 1 2 Cela 45 A cc 2 5 h dur e vous donnera une estimation grossi re de la puissance de batterie en A h d une ou 1 2 taux d inefficacit de plusieurs batteries que vous devrez connecter votre chargeur onduleur REMARQUE La puissance nominale en A h des batteries est habituellement donn e pour un r gime de d charge de 20 h Les capacit s r elles en A h sont moindres quand les batteries se d chargent un r gime plus rapide Par exemple des d charg es en 55 minutes fournissent seulement 50 de leur puissance nominale en A h tandis que les batteries d charg es en 9 minutes ne fournissent que 30 de leur puissance nominale en A h e TAPE 4 Estimation de la recharge de batterie requise selon votre application Vous devez laisser vos batteries se recharger assez longtemps pour remplacer la charge perdue pendant le fonctionnement de l onduleur ou vous puiserez 270 A h 55 A ventuellement vos batteries Pour estimer la dur e minimale de recharge de R gime du chargeur onduleur vos batteries selon votre application diviser la capacit requise en A h de votre batterie d apr s l tape 3 ci dessus par l amp rage nominal de charge de votre chargeur onduleur voir la feuille de sp cifications
81. t per met un transfert maximal de courant Votre chargeur onduleur est capable de d livrer un Connecteurs CC doubles voir wattage de pointe jusqu 200 de sa sortie de wattage nominal continu pendant de br ves p riodes Voir la page des sp cifica tions pour les d tails Il faut utiliser un cali bre plus gros quand un quipement qui con somme beaucoup fonctionne continuelle ment dans ces conditions Serrer vos bornes de chargeur onduleur et de batterie envi ron 3 5 Newton m tre de couple pour cr er une connexion efficace et emp cher un r chauffement excessif cette connexion Un serrage insuffisant des bornes peut annuler votre garantie Voir la page des sp cifications pour le tableau des tailles min imales de c ble recommand es e Connexion de mise la terre l aide d un fil de calibre 8 AWG ou plus gros connectez la cosse principale de mise la terre au ch ssis du v hicule ou la terre Voir la section Identification des caract ris tiques pour localiser la cosse principale de mise la terre sur votre mod le de chargeur onduleur Toutes les installations doivent tre conformes aux codes et r glemens locaux e Connexion de fusible L article 551 du code national de l lectricit NEC exige que vous connectiez toutes les bornes CC positives de votre chargeur onduleur directement des fusibles et des bloc fusibles UL moins de 457 mm 18 po de la batterie Le calibre
82. tery 12 Volts TRIPP LITE 12 Volt Inverter Charger 12 Volt Main Battery Connection TRIPP LITE 12 Volt Inverter Charger 12 Volt Main and Auxilia 1 12 Volt Alternator Vehicle Battery Ground 12 Volt Main Battery 12 Volt Auxiliary House Battery UL Listed Fuse amp Fuse Block mounted within 18 inches of the battery 6 Battery Isolator Large Diameter Cabling Maximum 2 0 Gauge to Fit Terminals E 8 AWG minimum Ground Wire NOTE Select models include two positive and two negative DC terminals Using the same connection architecture illustrated in the diagrams run two 2 0 gauge cables from the Inverter Charger 5 two negative terminals to the battery single negative terminal run two 2 0 gauge cables from the Inverter Charger 5 two positive terminals through two UL listed fuses and fuse blocks or equivalent one on each cable to the battery single positive terminal Use the equivalent of two 2 0 cables in all other connections within the battery system Connection to Two DC Terminals It is acceptable to use two cables to connect your battery to only one positive and one negative DC terminal however your Inverter Charger will provide reduced output power It doesnt make a difference which positive and negative terminal you choose for the connection because both positive terminals are internally bonded and both negative terminals are also internally bonded In this connection you must ru
83. tie Fonctionnement Modes de commutation Apr s avoir configur mont et connect votre chargeur onduleur vous tes capable de le faire fonctionner en commutant entre les diff rents modes de fonctionnement suivants corespondants votre situation AUTO REMOTE automatique distance Commuter vers ce mode lorsque vous avez besoin d une alimentation CA constante et ininterrompue pour les appareils et l quipement connect s Le chargeur onduleur fournira continuellement l alimen tation CA l quipement connect et chargera vos batteries connect es tant qu il y aura une alimentation CA de secteur ou fournie par une g n ratrice Comme le convertisseur est en marche ON mais en attente dans ce mode il commutera automa tiquement vers votre syst me de batterie pour alimenter en CA l quipement connect en l absence d une source secteur g n ratrice ou dans des situations de sous ou de surtension AUTO REMOTE permet aussi un module optionnel de commande distance mod le Tripp Lite APSRM4 vendu s par ment ou inclus avec les mod les Select de fonctionner lorqu il est connect l unit CHARGE ONLY charge seulement Commuter vers ce mode lorsque vous n utilisez pas les appareils et l quipement connect s pour conserver la puis sance de la batterie en d sactivant l onduleur Le chargeur onduleur fournira continuellement l ali mentation CA l quipement connect et chargera vos batter
84. ve All models include front and rear mounting feet Select models include side mounting feet Battery Connection Connect your Inverter Charger to your batteries using the following procedures e Connect DC Wiring Though your Inverter Charger is a high efficiency con verter of electricity its rated output capacity is limited by the length and gauge of the cabling run ning from the bat tery to the unit Use the shortest length and largest diameter cabling maximum 2 0 gauge to fit your Inverter Charger s DC Input terminals Shorter and heavier gauge cabling reduces DC voltage drop and allows for maximum transfer of current Your Inverter Charger is DC Connectors Dual DC Connectors See note at bottom of the page capable of delivering peak wattage at up to 200 of its rated continuous wattage output for brief periods of time See Specifications page for details Heavier gauge cabling should be used when continuously operating heavy draw equipment under these conditions Tighten your Inverter Charger and battery terminals to approximately 3 5 Newton meters of torque to create an efficient con nection and to prevent excessive heating at this connection Insufficient tightening of the terminals could void your warranty See Specifications Sheet for Minimum Recommended Cable Sizing Chart e Connect Ground Using a 8 AWG wire or larger directly connect the Main Ground Lug to the vehicle s chassis or
85. viceable or replaceable parts but should be kept dry at all times Periodically check clean and tighten all cable connections as necessary both at the unit and at the battery Troubleshooting Try these remedies for common Inverter Charger problems before calling for assistance Call Tripp Lite Customer Service at 773 869 1234 before returning your unit for service SYMPTOM No AC Output All Indicator Lights are OFF Battery Not Recharging AC Input Present PROBLEMS Unit is not properly connected to utility power CORRECTIONS Connect unit to utility power Operating Mode Switch is set to OFF and AC input is present Set Operating Mode Switch to AUTO REMOTE or CHARGE ONLY This is normal when the Operating Mode Switch is set to CHARGE ONLY and AC input is absent No correction is required AC output will return when AC input returns Set Operating Mode Switch to AUTO REMOTE if you require AC output Circuit breaker is tripped Reset circuit breaker Unit has shut down due to battery overcharge preventing battery damage The problem may be with connected auxiliary chargers if any or with the unit s charger Disconnect any auxiliary chargers Reset by moving Operating Mode Switch to OFF Wait 1 minute and switch to AUTO REMOTE or CHARGE ONLY If unit remains in shutdown mode after several attempts to reset contact Tripp Lite Customer Service
Download Pdf Manuals
Related Search
Related Contents
Protector Multi-Hazard Glove Boxes User`s Manual Manuel d`utilisation (en français) 広報げんきみね。3月号 No132(全ページ01)(PDF文書) くFID‐01SF FID‐01SS〉 Moto-Cart Jr Electric Lift Service Manual - Lift 4a606bfa13b507210_manual. ビデオの録画方法について GUIDE D`UTILISATION OTS-1 (512/4) OTS Mark 6 System User`s Manual SONDAR 3000-S - BeI The Deeter Group Copyright © All rights reserved.