1. POWER K POWER A Bp OQ BL RD WARRANTY All Trion air cleaners are warranted for component failure and workmanship for a period of three years after purchase Do not return defective parts without prior permission from the factory Contact your local Trion Distributor or Trion Customer Service Department at 800 884 0002 or Fax 800 458 2379 to obtain material return authorizations and service information air purification Systems A FEDDERS ENGINEERED PRODUCTS COMPANY 101 McNeill Road e Sanford NC 27331 0760 Customer Service 800 884 0002 e Fax 800 458 2379 www trioninc com e email sales trioninc com Manual Part Number 154385 002 June 2001 12
2. ELECTRONIC AIR PURIFICATION SYSTEM Eliminator Series SE400E and SE800E e INSTALLATION e OPERATION e SERVICE Electrostatic Precipitators for Commercial Applications TRI air purification systems A FEDDERS ENGINEERED PRODUCTS COMPANY 101 McNeill Road e Sanford NC 27330 919 775 2201 e Fax 919 777 6399 e 800 884 0002 www trioninc com MANUAL PART NO 154385 002 e September 2001 Contents Section Design Page 1 Introduction 3 2 The Filter System 3 3 Specifications 4 Section Il Installation 1 Installation 5 6 2 Diagfamsare ae 7 Section Ill Servicing and Maintenance 1 Servicing Maintenance 8 2 Parts AA Ces 9 3 Exploded ViewsS 10 Section IV Reference 1 Wiring Diagram SE400E 11 2 Wiring Diagram SE 800E 12 This manual provides information for installation operation and maintenance of your Trion SE400E amp SE800E Before installing and using the air purifier carefully read these instructions to ensure maximum benefits from the unit and to avoid needless service costs that may result from improper installation and maintenance Eliminator SE Series Section Design 1 Introduction The Trion Eliminator SE400E amp SE800E are commercial air purifiers that have been specifically designed to remove airborne pollutants including tobacco smoke dust p
3. 6 as shown in the wiring diagram on page 10 and 11 Mount the remote control in the desired position and connect the 5 conductor cable leads to the numbered terminals as shown in the wiring diagram OPTIONAL INFRARED CONTROL Main power to the unit is 120V 60Hz 1Ph rated 5 Amp Live Neutral and Ground To install follow the instructions included with the infrared control kit x 7 EYEBOLT Ng PERMANENT CEILING Ere ki FE 6 f NN LA ka Sagana V UNIT H SSE ASS SSSRA SSRS TEA 1 N EPA Taas FEN NG NUT WASHER of QD N N Ka N INNIINIIDEIDEDEIII le x 2 Diagrams FIGURE 1 FIGURE 2 FIGURE 5 FIGURE 6 Section Ill Service and Maintenance 1 SERVICING AND MAINTENANCE Beyond an occasional wipe down with a damp cloth the units need little in the way of maintenance However the units are designed to collect airborne dirt and from time to time will require routine servicing to remove the accumulation The service interval varies considerably between applications but typically will range from six weeks in a busy bar up to several months in a quiet office During normal operation the unit will make an occasional snapping noise This is caused by large pieces of dirt accumulating on the electronic filter and is not dangerous The Trion SE400E amp SE800E units have anti arcing circuitry to eliminate the nuisance of
4. Width 22 5 Length 22 5 SE800E Depth 9 5 Width 22 5 Length 46 12 Surface mounted recessed into suspended ceiling or wall SE400E only mounted 42 lbs shipping 48 Ibs 120 Volts 1 Phase 60 Hz 1 8 Amps 155 Watts Hard wired remote control with 3 speed selector switch with air dry fan only facility 1 20 HP 3 speed Ball Bearing 200 300 400 CFM 38 55 62 dBa Interlock to cell access door Anti arc circuitry Power to cell indicator Fresh air inlet Dry fan only cycle Infrared remote control Fresh air damper system 80 Ibs shipping 86 Ibs 120 Volts 1 Phase 60 Hz 3 4 Amps 270 Watts Hard wired remote control with 3 speed selector switch with air dry fan only facility 2 1 20 HP 3 speed Ball Bearing 400 600 800 CFM 41 58 65 dBa Interlock to cell access door Anti arc circuitry Power to cell indicator Fresh air inlet Dry fan only cycle Infrared remote control Fresh air damper system Eliminator SE400E amp SE800E Section II Installation 1 INSTALLATION CAUTION ELECTRONIC AIR CLEANERS CANNOT BE USED IN AREAS WHERE COMBUSTIBLE GASES OR VAPORS ARE PRESENT MECHANICAL The unit has been designed so that it can fit either surface mounted onto the ceiling semi recessed into a T Bar suspended ceiling or wall mounted SE400E only When installed with a T Bar suspended ceiling NEVER support the unit from the T Bars the unit must be supporte
5. constant arcing If however the arcing occurs every minute or two it is an indication that the unit needs cleaning When a service is due proceed as follows a Remove pre filter and either vacuum clean it or wash as described below b To clean the electronic filter soak it in a hot not boiling a strong non caustic detergent solution cleaner Trion can supply an excellent detergent TriDex obtainable through your Dealer Alternatively a dishwasher detergent does an excellent job Soak the collector cell for several hours then rinse with clean water Do not physically try to rub the dirt off since this can cause damage to the filter c Allow the filter to dry thoroughly preferably overnight and replace into the unit or alternatively use force air dry setting on the unit Trion has a policy of continuous product improvement and reserves the right to make changes in design and specification without notice 2 PARTS LIST Item Part Number Description Qty Unit Qty Unit SE400E SE800E 1 454027 001 Cabinet Assembly SE400E 1 2 454028 001 Cabinet Assembly SE800E 1 3 453844 001 Cell Access Cover 1 4 453844 003 Discharge Cover 1 2 5 453845 001 Cell Access Cover 2 6 153853 001 Hinge Pin 2 4 7 453855 001 Grill 4 6 8 453856 001 Corner 4 4 9 453857 001 Grill Filler 2 10 253863 001 P
6. the deep aluminum assembly Collector Cell located immediately behind the pre filter and is the heart of your air cleaner It uses an electrostatic charge to remove particles so small that it would take a pile of many millions to cover a pinhead When dirty it can be washed and reused indefinitely FILTER REMOVAL TRION SE400E Turn the control switch off before removing cell Press the two cell access latches and the hinged door will swing down Remove pre filter by turning pre filter clip 90 degrees fig 2 While supporting the weight of the Collector Cell loosen the filter retaining screw fig 3 The filter retaining plate will now open allowing the filter to be removed fig 4 To reinstall the filter simply reverse above procedure TRION SE800E The two hinged access doors are secured with retaining screws fig 3 Release screws to allow the doors to swing down Remove the Collector Cells as described above INSTALLATION LOCATION The most effective location for the air purifier is the center of the area to be cleaned because the dirty air is pulled into the center of the unit and discharged equally out the four sides If more than one unit is required space them evenly over the area to be cleaned Eliminator SE Series 3 Specifications Model Dimensions Installation Weight Input Power Power Consumed Controls Motor Air Flow Sound Rating Safety Feature Features Options SE400E Depth 9 5
7. d from the permanent ceiling SUSPENDED CEILING INSTALLATION To hang the unit into a suspended ceiling proceed as follows a Unpack the unit open filter access door and remove prefilter and cell see filter removal in section 2 b Install 4 20 eyebolts into mounting slots with large diameter washers and lock nuts as shown in sketch A Alternatively use drop rods c Install trim as shown in sketch A d Select and remove a ceiling tile near the center of the area to be cleaned by the unit e Attach a length of safety chain to each of the four eyebolts or fit threaded rod Fasten securely f Lift unit into place and support unit while securing to permanent ceiling ceiling joists etc See sketch A g Make electrical connections as detailed in next section h Re install cell and prefilter i Close access door and unit is ready for operation SOLID CEILNG MOUNTING To mount the unit to a solid ceiling proceed as follows a Unpack the unit open filter access door and remove prefilter and cell see filter removal in section 2 b Select a location near the center of the area to be cleaned If you are fitting to wooden ceiling joists locate the position of joists c Using the template provided drill four holes into the ceiling and fit four 5 16 lag screws in the joists Hex headed screws will give easier access for final tightening Do not tighten fully home d Lift the unit to where the la
8. ollen and mold spores in rooms and areas where people work or relax They are designed to be mounted onto a solid ceiling semi recessed for into a suspended ceiling or wall mounted SE400E only Where appropriate they can also draw in additional fresh air Their features make them the ideal air purifier for installations into areas such as offices conference rooms restaurants designated smoking areas institutions and waiting rooms or any other place where people gather HOW THEY WORK The Trion SE400E amp SE800E utilize the principle of Electrostatic Precipitation Air is drawn into the intake through the metal prefilter which traps lint and large dust particles The remaining particles some as small as 0 01 microns pass into a strong electrical field ionizing section where the particles receive an electrical charge The charged particles pass onto a series of equally spaced parallel plates collector section Each alternate plate is charged with the same polarity as the particles which are repelled while the interleaving plates are grounded and therefore attract and collect the particles The diameter of a human hair is about 100 micron 2 The Filter System There are two filters in your air cleaner THE PRE FILTER This is the mechanical filter that lies behind the inlet grill It is designed to remove large particles and can be washed many times before replacement THE ELECTROSTATIC FILTER This is
9. re filter 1 2 11 441730 103 Collector Cell 1 2 12 150685 001 Cell Retaining Clip 1 2 13 353842 001 Cell Latch 1 2 14 153854 001 Thumb Screw 1 2 15 244225 002 Bolt Retainer 1 6 16 345109 001 Cell Contact Assembly 1 2 17 453840 001 Cell Contact Support 1 18 453841 001 Cell Contact Support 1 19 242404 002 Interlock Switch 2 4 20 147214 001 Insulator 2 4 21 350950 003 Power Supply Assembly 1 1 22 254167 003 Step down Transformer 120V 24V 1 23 254167 004 Step down Transformer 120V 24V 1 24 453847 001 Motor Mounting Bracket 1 2 25 254026 002 Motor 120V 60Hz 1 2 26 142153 001 Ground Contact 1 2 27 254101 001 Fan 1 2 28 453858 001 Inlet Ring 1 2 29 EST 1124 Terminal Block 1 1 30 253850 001 Terminal Block Cover 1 1 31 253851 001 Duct Cover Plate 1 2 32 153848 001 Interlock Switch Actuator 1 33 153849 001 Interlock Switch Actuator 2 34 253852 001 Access Cover Latch 35 120035 210 Flat Head Screw 4 36 234711 002 Retaining Nut 4 37 354267 001 Remote Control Assembly 1 1 37a 250056 001 Rotary Switch 1 1 37b 242235 001 Switch Knob 1 1 3 Exploded Views SE400E SE800E 2 gt qd Bp 10 Section IV Reference 1 WIRING DIAGRAM SE400E 920 Ae AO 2 Ss I I ul CJ 5 gt CELI 11 2 WIRING DIAGRAM SE800E
10. rge end of the keyhole slots in the top of the cabinet fit over the screw heads Slide the unit so that the narrow ends of the mounting slots are located under the screw heads Tighten the screws fully home e Install the lockdown location screw as shown on template f Make electrical connections as detailed in next section g Re install cell and pre filter h Close access door and unit is ready for operation WALL MOUNTED SE400E Only Filter removal will be simpler if the unit is positioned with the access door hinge in a vertical plane Locate the wall studs and follow the mounting instructions for SOLID CEILING MOUNTING CAUTION IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENSURE ADEQUATE MOUNTING COMPONENTS ARE USED DO NOT ALLOW WEIGHT OF UNIT TO REST ON SUSPENDED CEILING SUPPORT RAILS ELECTRICAL WARNING THIS APPLIANCE MUST BE ELECTRICALLY GROUNDED NOTE This unit is designed to be permanently connected to fixed wiring Installation must comply with all applicable electrical codes Hard wired remote control Two sets of wiring are required to connect the unit Main power to the unit is 120V 60Hz 1Ph rated 5 Amp Live Neutral and Ground A 5 conductor 5 Amp rated cable is required from the unit to remote control Run the 5 conductor cable and the main power connection through the cable entry knockouts see Fig 5 in the cabinet and connect to the input terminal block Fig